Rural Development Department Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Rural Development Department - RDD Tender

Works
Civil And Construction
Bridge Construction
Eprocure
Opening Date7 Apr 2023
Closing Date15 Apr 2023
Tender Amount₹ 5,51,09,835 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying, fiiting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications.

95.75

8368401

87394.8

... More
Bored Cast-in-situ M35 grade RCC pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000m. (Pile diameter - 1200mm).

539.6

4404700

8162.9

... More
Providing Steel liner 6mm thick for piles including fabricating and setting out as per detailed drawing (Unit Weight = 47.1 kg/sqm.

27.35

2613383

95570.8

... More
Plain/Reinforced cement concrete (RCC Grade M30 using batching plant, transit mixer & concrete pump) in substructure complete as per drawing and technical specifications. (Height upto 5m)

156.15

733030

4694.4

... More
Supplying, fiiting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specification.

24.93

2187129

87744.9

... More
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structures with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.

50

5525

110.5

... More
Providing and laying of filter media with granular materials/tone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRT&H specifications to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification.

65.43

107651

1645.3

... More
Supplying , fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83 (Part-II) section IX and clause 2005 of Mort&H specification complete including all accessories as per drwaing and technical specifications

403200

326592

0.81

... More
Back filling behind abutment, wing wall and return wall (with Sandy Material) complete as per drawing and Technical specification

115.12

100683

874.6

... More
Furnishing and placing Reinforced/Prestressed cement concrete (RCC Grade M30 using batching plant, transit mixer and concrete pump) in super-structure (for T-beam & slab) as per drawing and Technical Specification.(Height 5m to 10m)

390

2143401

5495.9

... More
Supplying, fiiting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specification.

57.52

5055211

87893.8

... More
Providing and laying cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Techncial Specifications.

54.45

592225

10876.5

... More
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance to vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications.

207.68

412784

1987.6

... More
Drainage Spouts complete as per Drawing and Technical Specification.

40

32716

817.9

... More
PCC M15 Grade (using batching plant & concrete pump) levelling course below approach slab complete as per drawing and Technical Specification.

5.25

17879

3405.64

... More
Reinforced cement concrete in approach slab including reinforcement and formwork complete as per drawing and Technical specification. (RCC M30)

15.75

137774

8747.6

... More
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.)

50.7

521703

10290

... More
CONSTRUCTION OF APPROACH ROAD Excavation in Soil with Dozer with lead upto 100 metres (Excavation for road way in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 1000 metres (average lead 50 metres), including trimming bottom and side slopes in accordance with requirements of lines, grades and corss sections.)

170.73

26394

154.6

... More
Embankment Construction with Material Obtained from Borrow Pits (Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)

5754.02

747447

129.9

... More
Compacting original ground supporting embankment (Loosening of the ground upto a level of 500 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of table 300-2 for subgrade construction.)

794.25

41777

52.6

... More
Granular Sub-Base with Graded Material (Shoulder) with Close Graded Material Gr-I (By Mix in Place Method) Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.

132.38

190309

1437.6

... More
Granular Sub-Base with Graded Material (Carriageway) with Close Graded Material Gr-I (By Mix in Place Method) Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.

214.45

308293

1437.6

... More
Wet Mix Macadam (Plant Mix Method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with grader in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

99.28

168885

1701.1

... More
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing )

264.75

1419165

5360.4

... More
Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25-1967, fixed in position including finishing and lettering but excluding painting. (2x2x25 Nos. = 100 Nos.)

100

54580

545.8

... More
CONSTRUCTION OF RETAINING WALL Earth work in excavation of foundation ( Depth upto 3 m ) of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

856.9

49186

57.4

... More
Plain/Reinforced cement concrete (PCC Grade M15 using batching plant & concrete pump) in open foundation complete as per drawing and technical specifications.

62.7

211681

3376.1

... More
Reinforced cement concrete (RCC Grade M25 using batching plant transit mixture & concrete pump) in open foundation complete as per drawing and technical specifications.

254.38

1113751

4378.3

... More
Reinforced cement concrete (RCC Grade M25, height upto 5m) in substructure complete as per drawing and technical specifications. (Stem)

125.13

579464

4630.9

... More
Supplying, fiiting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications.

15.85

1385469

87394.8

... More
Supplying, fiiting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specification.

19.67

1725591

87744.9

... More
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return all with 100 mm dia AC pipe, extending through the full width of the structures with slope of 1V:20H towards drawing foce. Complete as per drawing and Technical specifications.

165

18232

110.5

... More
CONSTRUCTION OF GUARD WALL Earth work in excavation of foundation (Depth upto 3 m ) of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

675

38745

57.4

... More
Plain/Reinforced cement concrete (PCC Grade M15 using batching plant & concrete pump) in open foundation complete as per drawing and technical specifications.

112.5

379811

3376.1

... More
Random rubble stone masonry work in cement mortar 1:3 in foundation complete as drawing and Technical Specification.

400

1383440

3458.6

... More
Random rubble stone masonry work in cement mortar 1:3 in substructure complete as drawing and Technical Specification.

435.94

1512188

3468.8

... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications.

15

62523

4168.2

... More
Pointing with cement mortar (1:3) on stone work as per Technical specifications.

562.5

32478

57.74

... More
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return all with 100 mm dia AC pipe, extending through the full width of the structures with slope of 1V:20H towards drawing foce. Complete as per drawing and Technical specifications.

125

13812

110.5

... More
CONSTRUCTION OF RCC SLAB CULVERT (3mx2.5m) Earth work in excavation of foundation (Depth upto 3 m) of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

118.62

6808

57.4

... More
Sand Filling in Foundation Trenches as per Drawing & Technical Specification

2.42

1373

567.8

... More
Plain/Reinforced cement concrete (PCC Grade M15 using batching plant & concrete pump) in open foundation complete as per drawing and technical specifications.

16.85

59691

3541.9

... More
Random rubble stone masonry work in cement mortar 1:3 in foundation complete as drawing and Technical Specification.

68.28

236160

3458.6

... More
Random rubble stone masonry work in cement mortar 1:3 in substructure complete as drawing and Technical Specification.

61.06

211804

3468.8

... More
Plain/Reinforced cement concrete (PCC Grade M20)in sub-structure complete as per drawing and technical specifications.

5.21

21707

4168.2

... More
RCC M25 in Deck Slab :-- Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification

9.61

48097

5003.9

... More
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications

1.24

109339

87893.8

... More
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight

18

482

26.8

... More
Random rubble stone masonry work in cement mortar 1:3 in substructure complete as drawing and Technical Specification.

2.11

7326

3468.8

... More
Plain/Reinforced cement concrete (PCC Grade M20) in sub-structure complete as per drawing and technical specifications.

0.26

1100

4168.2

... More
Plastering with cement mortar (1:3) on brick work in sub-structure as per Technical specifications

97.62

9840

100.8

... More
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structures with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.

40

4420

110.5

... More
Providing and laying of filter media with granular materials/tone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRT&H specifications to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification.

3.53

5804

1645.3

... More
Back filling behind abutment, wing wall and return wall (with Sandy Material) complete as per drawing and Technical specification

39.54

34582

874.6

... More
CARRIAGE OF MATERIALS Cement, Sahebganj 60 Km.(P) + 0 Km (K)

1166.69

1128886

967.6

... More
Steel, Sahebganj 60 Km.(P) + 0 Km (K)

249.67

241579

967.6

... More
Sand, Amrapara (Dumka) 58 Km.(P) + 2 Km (K)

1483.67

1552211

1046.2

... More
Chips, Borna Pahari (Pathna) 12 Km.(P) + 3 Km (K)

2422.08

958659

395.8

... More
Boulder, Borna Pahari (Pathna) 12 Km.(P) + 3 Km (K)

967.39

553724

572.39

... More
Aggregate, Borna Pahari (Pathna) 12 Km.(P) + 3 Km (K)

466.12

195942

420.37

... More
GST @ 18%

46240841.66

8323351

0.18

... More
Labour cess @ 1%

54564193.15

545641

0.01



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.