Rural Development Department Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Rural Development Department - RDD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date2 Feb 2024
Closing Date9 Feb 2024
Tender Amount₹ 10,78,287 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. (BCD/5.6.3 )

39.72

13121

330.34

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) (BCD/5.3.1.3 )

3.01

13555

4503.43

... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). (BCD/5.3.2.1 )

1.41

7357

5218

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) (BCD/5.3.9.1 )

0.68

3548

5218

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) (BCD/5.3.10 )

2.52

15327

6082.45

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (BCD/5.3.11 )

9.93

62647

6308.87

... More
Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (BCD/5.7.14 )

58.11

10990

189.13

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete (BCD/5.3.17.1 )

10.58

2057

194.5

... More
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform (BCD/5.3.17.3 )

12.18

5308

435.82

... More
Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases (BCD/5.3.17.7 )

3.43

1234

360

... More
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts

39.8

18522

465.38

... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers (BCD/5.3.17.5 )

20.07

7304

363.97

... More
Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. (BCD/5.2.6 )

6.17

31530

5110.26

... More
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). (BCD/5.3.5 )

6.75

1878

278.35

... More
Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. (BCD/5.2.14 )

23.55

123498

5244.08

... More
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (BCD/5.7.3 )

169.56

28113

165.8

... More
Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (BCD/5.7.6 )

58.11

10695

184.06

... More
Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I. (BCD/5.7.11 )

12.41

675

54.43

... More
Making 6X6mm grooves in plaster surface over walls truely horizontal or vertical as specified at regular intervals, at all heights including cleaning, finishing, scaffolding and curring with all leads and lift of water all complete as per building specification and direction of E/I. (BCD/5.7.21 )

94.97

9941

104.68

... More
providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for JSOR) (i) Rod 8 mm dia (BCD/5.5.4 )

0.37

30976

83314.02

... More
providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. (i) Rod 10 mm dia (BCD/5.5.5a )

0.56

45785

82096.54

... More
(b) 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) (BCD/5.5.5b )

0.93

75185

80879.07

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (BCD/5.3.8 )

10.34

3637

351.75

... More
Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. (BCD/5.10.33 )

13.57

19619

1445.77

... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. (DSR/11.41A.3 )

38.71

44001

1136.7

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, includinghinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded orrigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C Fixing with adjustable lugs with split end tail to each jamb (DSR/10.14.2.1 )

6.1

2516

412.54

... More
supplying, fitting and fixing 250X20X6mm L-type M.S clamp properly fishtailed, including maiking holes and setting as same in 250 X 125 X 75mm. Cement concrete block (1:2:4) with cost of all labour and materials and taxes as per building specification and direction of E/I.

8

650

81.34

... More
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with one side teak decorative and another side commercial veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.

2.97

5479

1844.86

... More
Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) (BCD/5.5.12 )

156

12840

82.31

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm) (DSR/21.3.1 )

4.83

4934

1021.62

... More
White washing three coats over new surface with approved quality of lime including cost of cleaning surface thoroughly and removing the scales of smoke and mosh marks with jhama rubbing, scaffolding, washing, of floors and taxes all complete as per building specification and direction of E/I. (BCD/5.8.3 )

58.11

991

17.07

... More
Colour washing two coats over a coat of white wash over new surface with approved quality of lime in approved shade including cost of cleaning surface thoroughly and removing the scales of smoke and mosh marks with jhama rubbing,scaffolding,washing,of floors and taxes all complete as per building specification and direction of E/I. (BCD/5.8.6 )

93.54

2235

23.9

... More
Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding , curing and taxes all complete as per building specification and direction of E/I. (BCD/5.8.24 )

76.02

8291

109.07

... More
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) (BCD/5.8.41 )

4.83

279

57.77

... More
Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (BCD/5.8.45 )

4.83

318

66.04

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR/12.41.2 )

2.44

676

277.2

... More
CARRIAGE: (A) SAND

38.35

36863

961.24

... More
(B) S.CHIPS

15.52

6239

402.04

... More
('C) BRICKS

13.36

14206

1063.6

... More
(D) CEMENT

16.73

7163

428.2

... More
(E) STEEL

1.86

796

428.2

... More
ELECTRICAL: Point wiring in PVC conduit, with modular type switch - Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required. Group B ( Energy/1.3.2 )

14

9884

706

... More
Power plug wiring in PVC conduit (2 x 4 sq.mm) - Wiring for light/power plug with 2 x 4 sq.mm. FR PVC insulated copper conductor single core cable in surface recessed PVC conduit, along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. ( Energy/1.5 )

180

47160

262

... More
Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire ( Energy/1.7.1 )

180

26460

147

... More
Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire ( Energy/1.7.2 )

180

35280

196

... More
Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.2 x 6.0 sq.mm. + 1 x 6.0 sq.mm. earth wire ( Energy/1.7.4 )

90

31590

351

... More
S/F Call bell buzzer - Supplying and fixing call bell/buzzer suitable for D.C./A.C. single phase, 230 volts, complete as required. ( Energy/1.38 )

1

82

82

... More
S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc. as required . (For light plugs to be used in non residential buildings) ( Energy/1.31 )

6

1932

322

... More
S/F power plug point with Modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface of in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required. (For light plugs to be used in non residential buildings) ( Energy/1.32 )

1

405

405

... More
S/F PVC conduit - Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required.20mm ( Energy/1.21.1 )

180

10800

60

... More
S/F Modular type switch socket - Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required 5/6 amps, 3 pin socket outlet ( Energy/1.24.4 )

3

264

88

... More
S/F Modular boxes, base & cover plate - Supplying and fixing following size/modules G.I. box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 module (78mm x 78mm x 45mm) ( Energy/1.27.1 )

3

507

169

... More
S/F Modualr type blanking plate - Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required. ( Energy/1.26 )

3

63

21

... More
Copper earth plate elecrtode - Earthing with copper earth plate 600mmx 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (with charcoal or coke and salt) ( Energy/3.6 )

1

10666

10666

... More
S/L 8 SWG copper wire in ground - Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required ( Energy/3.7 )

1

140

140

... More
P/F 25mmx 5mm G.I. earth strip in ground - Providing and fixing 25mm x 5mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. ( Energy/3.9 )

3

342

114

... More
ITC exhaust fan upto 450 mm sweep - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.( 1.48, energy)

3

183

61

... More
12" (300mm) metal exhaust fan (M-775,pg-52,energy)

3

3877

1292.5

... More
S/F Modular type electronic fan regulator - Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. ( Energy/1.25 )

2

586

293

... More
Supply, Installation, Testing and Commissioning of following size fan 3 Blades confirming to IS:374:2019 including wiring the down rods of stranded for 230 V 50 Hz, single phase supply etc. complete as required 1200mm (48") BLDC 5star rating 32W Ceiling Fan ( Energy/9.4.3 )

2

6700

3350

... More
S.I.T.C. of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. 20/22 W LED Tube light ( Energy/9.5.2 )

2

1256

628

... More
S.I.T.C of following rating reccess/surface mounted LED round/square shape down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirmed to IS: 10322 part-5/section-2 or IEC-62722 with all necessary accessories as required.18/20 W LED Round Down light ( Energy/9.3.4 )

2

2316

1158

... More
S/F MCCB in cubical panel board - Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board, including drilling holes in cubical panel, making connection, etc. as required. 25-100 amps, 16 KA, fixed thermal setting ( Energy/2.4.2 )

1

3557

3557

... More
S/F sheet metal ON/OFF Load changeover - Providing and fixing capacity 2 pole/4 pole ON/OFF load changeover switches with side handle operation, in sheet enclosure in existing metal board including drilling holes in metal board, making connection, earthing the body etc. as required. 63 amps, 2 pole ( Energy/2.6.2 )

1

3698

3698

... More
S/F S.P. MCB DB - Supplying and fixing following way, single pole and netural, steel sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 12 way, single door (Energy/2.8.5)

2

1960

980

... More
S/F 'B' series, S.P. MCB - Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, 'B' curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required 6/32 amps, single pole "B" series ( Energy/2.11.1 )

2

364

182

... More
Supply, Installation, Testing and Commissioning of following size fan 3 Blades confirming to IS:374:2019 including wiring the down rods of stranded for 230 V 50 Hz, single phase supply etc. complete as required 1200mm (48") Ceiling Fan ( Energy/9.4.1 )

2

3496

1748

... More
(b) Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. Brass revolving fitting 3mm ply wood board and C.P. Hinges to fix with mirror. (i) 600mm X 450mm size DWSD/3.1.21 b

2

2873

1436.59

... More
Goods & Service Tax (G.S.T.) -@18%

1

162855

162855.85

... More
Labour Cess -@1%

1

10676

10676.11



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.