Rural Development Department Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Rural Development Department - RDD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date16 Mar 2024
Closing Date22 Mar 2024
Tender Amount₹ 49,48,091 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).(5.3.5)

25

6958

278.35

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.(5.3.8)

61.2

21527

351.75

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) (5.3.9.1)

32.31

168593

5218

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).(5.3.11)

34.24

216015

6308.87

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).(5.3.11)

12.38

78103

6308.87

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)(5.3.10)

8.51

51731

6082.45

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete.(5.3.17.1)

18

3501

194.5

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers.(5.3.17.5)

235.09

85565

363.97

... More
Columns, Pillars, Piers, Abutments, Posts and Struts.(5.3.17.6)

121.5

56543

465.38

... More
Suspended floors, roofs, landings, balconies and access platform(5.3.17.3_

273.88

119362

435.82

... More
providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (5.5.4)

2.19

182457

83314.02

... More
providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. (a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}(5.5.5(a)

3.28

269276

82096.54

... More
(b) 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)})(5.5.5(b)

1.09

88158

80879.07

... More
(c) 16mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)})(5.5.5©

2.19

177125

80879.07

... More
providing Tor steel reinforcement of 20mm,25mm, 28mm & 32mm. dia bars as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. 20/25mm TMT bar Fe 500 (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)})(5.5.6)

2.19

177125

80879.07

... More
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.(5.2.52)

38.33

172836

4509.16

... More
Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I.(5.2.54)

218.31

126248

578.3

... More
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS: 2095: (part I): 2011 (Board with BIS certification marks) (DSR- 9.105.2)

45.01

59785

1328.28

... More
Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge 10.14.1 Profile B Fixing with adjustable lugs with split end tail to each jamb(DSR-10.14.1.1)

78.4

30252

385.88

... More
Supplying, fitting and fixing 30mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.(5.4.34)

21

42784

2037.34

... More
Supplying, fitting and fixing 35mm thick solid core type decorative double leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.(5.4.33)

11.34

26172

2307.97

... More
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately)(DSR-21.18)

8.4

33111

3941.9

... More
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Powder coated minimum thickness 50 micron aluminium tubular handle bar.(DSR-21.12.2)

4

1956

489.19

... More
roviding and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. (DSR- 21.13)

10

3902

390.27

... More
Providing average 150mm thick dry rammed khoa beaten to112mm.(compacted with water) made of well burnt or jhama bricks including ramming properly till compacted thckness is achieved, curing and carriage of water with all leads,making proper slope and blending the top with cement morter (1:10) all complete as per building specification and direction of E/I.(5.6.5)

240

46012

191.72

... More
Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .(5.6.28)

165

156804

950.33

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (SDR-8.31)

44

40621

923.21

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR- 11.37)

12

9746

812.22

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding els.Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm. (DSR-8.2.2.2)

9

34575

3841.77

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work. (DSR-8.3.2)

16

5817

363.62

... More
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR- 8.5)

4

2806

701.58

... More
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile.(DSR- 11.21.1.1)

53

69726

1315.6

... More
In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile (DSR- 11.21.2.1)

44

62556

1421.73

... More
Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. (5.6.19)

36

64505

1791.83

... More
Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. (DSR- 5.6.20)

3

5601

1867.29

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 12.21.1 In 75x75 mm deep chase (DSR-12.21.1)

64

14456

225.89

... More
Providing and filling of 6 mm thickGroove between 50 mm PCC Panels with 6 mm thick 25 mm deep thermocol strip and filling the rest 25 mm with Polysulphide Sealant (Poring Grade)as per (5.12.9)

64

6192

96.75

... More
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.(5.7.3)

559.32

92735

165.8

... More
Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.(5.7.6)

273.88

50410

184.06

... More
Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.(5.7.15)

301.59

78947

261.77

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complet.(DSR- 13.80)

1134.8

122013

107.52

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).(DSR- 13.47.1)

301.59

42385

140.54

... More
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.(5.8.18)

833.2

75121

90.16

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion : Powder coated aluminium (minimum thickness of powder coating 50 micron).(DSR- 21.1.1.2)

153.62

62186

404.81

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately): Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR- 21.1.2.2)

145.7

71439

490.32

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm).(DSR- 21.3.2)

19.53

22474

1150.75

... More
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.:Upto 5mm depth and 5 mm width.(DSR- 21.8.1)

71.02

5256

74.01

... More
Add Carriage of Materials : Sand Lead- 40 KM

132.19

22366

169.2

... More
Stone Chips Lead- 15 KM

94.12

27309

290.16

... More
Brick Lead- 45 KM

28.12

20842

741.2

... More
Electrical:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, sutable size G.I. box etc. as required. Group C.(1.3.3)

60

51840

864

... More
Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 Nos. 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.(1.5)

80

20960

262

... More
Circuit/Summain Wiring: Wiring for Circuit/submain wiring along with earth wire with the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as requried.: 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire.(1.7.1)

220

32340

147

... More
2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire(1.7.2)

75

14700

196

... More
Supplying and drawing co-axial TV cable RG-6 grade copper conductor, PE insulated, with PVC sheath in the existing surface/recessed PVC conduit as required.(1.17)

60

2340

39

... More
Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required.. 25 mm (1.21.2)

170

11050

65

... More
30 mm. (1.21.3)

100

6900

69

... More
Sypplying and fixing following modular type switch/ socket on the existing modular plate and switch box including connection but excludng modular plate etc. as required.5/6 amps, one way switch.( 1.24.1)

70

4690

67

... More
15/16 amps, one way switch. ( 1.24.3)

20

2040

102

... More
3 pin 5/6 amps, socket outlet. (1.24.4)

20

1760

88

... More
15/16 amps, 6 pin socket outlet. (1.24.5)

20

2900

145

... More
TV antenna socket outlet. ( 1.24.7)

2

162

81

... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding moudlar plate etc, as required.( 1.25)

14

4102

293

... More
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required.. (1.26)

10

210

21

... More
Supplying and fixing following size/ modules G.I. box along with modular base & cover plate for modular swiches in recess etc as required. 1 or 2 module (78mm x 78mm x 45mm). (1.27.1)

8

1352

169

... More
4/5 module (78mm x 140mm x 50mm).(1.27.2)

20

4080

204

... More
8/9 module (78mm x 230mm x 60mm).(1.27.4)

15

4320

288

... More
Supplying and fixing 2 pin 5 amp, Celiling rose on the existing junction box/ wooen block including connection etc. as required.(1.33)

25

1125

45

... More
Supplying and fixing batten/ angle holder including connetion etc as required.(1.34)

15

885

59

... More
Supplying and fixing dingdong call bell suitable or D.C/A.C single phase, 230 volts, complete as required.(1.36)

2

296

148

... More
Installation, testing and commissioning of Pre-wired, flourscent fitting/ compact flourescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, includin connecton with 1.5 sq. mm. FR PVC insulated, copper cond. (1.41)

4

424

106

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required.. (1.44)

14

1554

111

... More
Installation of exhaust fan upto 450 mm, sweep in the existing opening, includig making the hole to suit the size of the above fan making good the damage, connection, testing, commissioning etc as required.. (1.48)

3

183

61

... More
S/F T.P MCB DB :- Supplying and fixing following way three pole netural, sheet, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (but without MCB/RCCB/Isolator) : 6 way (4 + 18), Double door, horizontal type.(2.9.5)

2

5014

2507

... More
S/F 'C' series MCB :- Supplying and fixing following, 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqired.: 6/32 amps, Single pole.(2.12.1)

10

1820

182

... More
6/32 amps, TPN. (2.12.8)

4

3628

907

... More
40 amps, TPN. (2.12.9)

4

4812

1203

... More
S/F SPN RCCB :- Supplying and fixing following rating, double pole, (Single phase and netural) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissiononing etc. as required.63 amps.(2.16.3)

2

4016

2008

... More
P/F M.V danger notice plate :- Providing and fixing M.V danger notice plate of 200mm x 150mm, made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required..(2.19)

2

328

164

... More
Earthing with G.I earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having loc king arrngement and watering pipe etc .( without charcoal or coke and salt) as required.(3.4)

1

5134

5134

... More
Providing and fixing 6 SWG dia G.I wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/. (3.18)

60

1560

26

... More
Supply and laying of following size of 1.1 KV grade multistandard copper conductor PVC insulated cable including termination complete as per required in existing cable tray.: 10 x 16 sq.mm PVC Insulated Cu wire including termination etc.(M/R)

45

10260

228

... More
S.I.T.C of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz.,single phase supply etc.complete as required. 10/12 W LED Tube light.(9.5.1)

18

9432

524

... More
20/22 W LED Tube light. (9.5.2)

20

12560

628

... More
Supply Installation, testing and commissioning of following size ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated ,copper wire suitable for for 230 V 50 Hz.,single phase supply etc.complete as required. 1200 mm (48'') BLDC 5 Star rating 32 W Ceiling fan. (9.4.3)

14

46900

3350

... More
SITC of 300 mm (12") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz, AC supply complete with Motor, louvers/shutters etc. complete as required Make: Usha/Crompton/Havells.( Item-M-775)

4

4700

1175

... More
SANITARY INSTALLATION: Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. connection pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/I. (B). E.W.C. With 'S' trap. (b) 10.00 lit. low level PVC Cistem' (3.2.2)

4

19147

4786.86

... More
Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.(3.2.5)

2

4168

2084.36

... More
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 450x300x150 mm. (DSR- 17.11.1)

4

14986

3746.56

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe,: 32 mm dia. (DSR- 17.28.2.1)

11

996

90.59

... More
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.(DSR- 17.71)

8

1016

127.01

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. (DSR- 17.72)

8

1421

177.71

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore (DSR- 18.49.1)

8

3015

376.94

... More
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.; 15 mm nominal bore.(DSR- 18.50.1)

8

4966

620.75

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ; 15mm nominal bore.(DSR- 18.53.1)

10

4343

434.37

... More
Providing and fixing toilet paper holder :; C.P. brass.(DSR- 17.34.1)

4

2364

591.02

... More
Providing and fixing flanged cleanout plug with M.S. flanged fail pieces, blind flang, 6 mm dia nut & bolts, gasket and washers fixed to C.I.pipe with drip seal joint complete in all complete including cutting and making good the walls and floor wherever required. with 100 mm dia pipe. (M/R)

4

4568

1142

... More
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length; 15 mm nominal bore.(DSR- 18.21.2.1)

15

1109

73.96

... More
12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.(DSR- 12.22)

2

462

231.44

... More
DRAINAGE INSTALLATION: Supplying fitting and fixing H.C.I. pipes with ear of approved make confirming to I.S.I. 1729 including supplying nails and bobins short pieces, cutting loose collars,lead and yarn for making lead caulked joints, cutting pipes to size including earth work or scaffolding where necessary etc. all complete as per specification and direction of E/I. (3.2.7)(A) 100 MM DIA

10

12559

1255.91

... More
(B) 75 MM DIA

10

9190

919.08

... More
( C) 50 MM DIA

10

7300

730.01

... More
Supplying and fixing H.C.I. fittings of approved make confirming to I.S.S.1729including supplying nails and bobines lead and yarn from making lead caulked joints including earth work or providing scaffolding as the case may be all complete as per specification and direction of E/I.(3.2.8) (A) H.C.I. single junction with door but without ear except socket. (i) 100 mm dia (wt. 10.5 Kg. app.)

4

4882

1220.55

... More
(B) H.C.I. Heal Rest bend. (i) 100 mm dia (wt. 5.5 Kg. app.)

4

2754

688.69

... More
Supplying all tools and labours and cutting chajja, Cornice, for laying H.C.I. pipes and making good the same as per specification and direction of E/I. (3.2.9)

4

798

199.67

... More
Cutting drain width wise above G.L. for laying H.C.I. pipe and restoring brick work in cement mortar (1:4) 12mm cement plaster in (1:4) with neat cement punning as per specification and direction Each of E/I. (3.2.10

4

798

199.67

... More
Making holes in walls for laying H.C.I. pipes and restoring the same after pipe laying as per specification and direction of E/I. (i) 125 mm dia .(3.2.11)

4

617

154.32

... More
Supplying materials and labour for painting the exposed H.C.I. pipes and fittings with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. (3.2.12) (i) 50 mm dia

12

364

30.37

... More
(ii) 80 mm dia

12

560

46.7

... More
(iii) 100 mm dia

12

672

56.03

... More
Providing, Fixing, testing and commissioning of UPVC pipe SWR type 'B' conform to : 13592-1992 with all fittings such as bends, tees, elbow, 'Y' , offset, clearing pipe door, clamps and steel stuctural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conform to : IS 13592-1992 type 'B'. The fitting dimension conforming to IS: 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint.(A) 110 mm (OD) SWR Pipe

15

9346

623.11

... More
WATER SUPPLY INSTALLATION: Providing and fixing Polyethelene-Aluminium-Polyethelene PE-AL PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer-in-charge. 18.1.3 2025 (25 mm OD) pipe. (DSR- 18.10.3)

32

13645

426.42

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (DSR-18.8.1) 15 mm nominal dia Pipes metre 441.15

10

3829

382.97

... More
(DSR-18.8.2) 20 mm nominal dia Pipes

30

13380

446

... More
(DSR-18.8.3) 25 mm nominal dia Pipes

30

16304

543.49

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR-18.17.2) 32 mm nominal bore.

4

2048

512.11

... More
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : (DSR-18.40.3) 25 mm diameter pipe

26

344

13.24

... More
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : (DSR- 18.46.4) 32 mm nominal bore

1

355

355.45

... More
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. (DSR- 17.30)

5

196

39.33

... More
Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : (DSR- 18.37.1) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

1

7831

7831.2

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type: (DSR- 19.4.3.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

2199

2199.83

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR- 19.6.2) 150 mm dia. R.C.C. pipe

10

4280

428.07

... More
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(DSR- 18.48)

2000

16840

8.42

... More
Providing storing handling, Installation, Testing and commissioning of portable fire Extinguishers as described below.(A) 4.5 kg carbon dioxide extinguisher, IS marked with high pressure dishcharge tube, hom, control valve, CCE approved cylinder.

2

18412

9206.49

... More
(B) 6 Kg mono Ammoniuom phosphate (ABC) type cartrige operlated extinguishers.

2

14905

7452.87

... More
SEPTIC TANK: Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.(5.1.1)

27.33

4149

151.82

... More
Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)(5.1.2)

27.33

423

15.51

... More
Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)(5.1.10)

0.93

548

589.51

... More
Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.(5.2.6)

7.12

36385

5110.26

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size).(5.3.1..3)

1.9

8556

4503.43

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. (5.3.17.1)

2.37

460

194.5

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)..(5.3.11)

0.24

1514

6308.87

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers.(5.3.17.5)

3.93

1430

363.97

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)..(5.3.11)

1.73

10914

6308.87

... More
Suspended floors, roofs, landings, balconies and access platform.(5.3.17.3)

13.83

6027

435.82

... More
providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. (a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)} (5.5.5(a)

0.15

12314

82096.54

... More
(b) 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)})(5.5.5.b)

0.02

1617

80879.07

... More
Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.(5.6.3)

16.38

5410

330.34

... More
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.(5.7.1)

41.38

7473

180.6

... More
Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I.(5.7.11)

41.38

2252

54.43

... More
Carriage of material; (a) Bricks

3.42

2537

741.2

... More
(b) Sand

4.97

841

169.2

... More
(c') Stone chips

3.41

990

290.16

... More
(d) Local Sand

0.95

94

98.64

... More
GST@ 18%

1

741999

741999.24

... More
Labour Cess @ 1%

1

48642

48642.17



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.