Road Construction Department Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 29,90,000Document Cost
₹ 10,000Tender Fee
Refer Documents
Summary
Widening And Strengthening/reconstruction Of Srikund (on Rcd Road) To Shivapahar (on Rcd Road) Via Madhuwapada Angoli Hastipara Juhibona
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CECOM_95954_1Bid Award Id
ViewTender No
RCD/SAHIBGANJ/762/2024-25Tender Authority
Road Construction Department ViewPurchaser Address
-Website
http://jharkhandtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Scarifying the existing bituminous surface to a dept of 50mm and disposal of scarified material within all the lifts and leads upto 1000 metres. RCDSOR 3.15 (i)
3220
-
-
... More
Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a alead of 1000 metres, stackiung serviceable and unserviceable materials separately. RCDSOR 2.06
750
-
-
... More
Dismantling of kilometre stone including cutting of earth foundation and disposal of dismantled material with all lifts and lead upto 1000 metres and back filling of pit. 5th KM Stone. RCDSOR 2.10 (A)
1
-
-
... More
Dismantling of kilometre stone including cutting of earth foundation and disposal of dismantled material with all lifts and lead upto 1000 metres and back filling of pit. (B) Ordinary KM Stone. RCDSOR 2.10 (B)
3
-
-
... More
Dismantling of kilometre stone including cutting of earth foundation and disposal of dismantled material with all lifts and lead upto 1000 metres and back filling of pit. (C) Hectometre Stone. RCDSOR 2.10 (C)
9
-
-
... More
Removal of telephone/Electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately. RCDSOR 2.14
29
-
-
... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m. Ordinary Soil. RCDSOR 3.06
5161
-
-
... More
Construction of Embankment with approved material obtained from Borrow pits with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300-2. RCDSOR 3.16
85175.55
-
-
... More
Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundatioin of other structures graded and compacted to meet requirement of Table 300-2 RCDSOR 3.17
9774.95
-
-
... More
Construction of sub grade. Stone crusher dust. NS (M004)
45680.67
-
-
... More
Construction of sub-grade and earthen shoulder with approved material obtained from Borrow pits with approved material obtained from borrow pits with all lifts and lead, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300-2 RCDSOR 3.18
12451.32
-
-
... More
Construction of granular sub-base by providing graded Material, mixing, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface mixing with cement at OMC and compacting with vibratory power roller to achieve the desired density, complete as per clause 401. RCDSOR 4.01 B (v)
18013.75
-
-
... More
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub-base /base course on well prepared surface and compacting with vibratory roller to achieve the desired density. RCDSOR 4.14 B
12081.73
-
-
... More
Prime coat over WMM/WBM. Providing and applying primer coat with SS1 grade bitumen emulsion on prepared surface of granular base including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means. RCDSOR 5.01 A (i)
48326.92
-
-
... More
Tack coat on Granular surface treated with primer. Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared granular surface cleaned with mechanical broom. RCDSOR 5.02 (i)
46340.88
-
-
... More
Tack coat on Granular surface treated with primer. Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared granular surface cleaned with mechanical broom. RCDSOR 5.02 (ii)
46340.88
-
-
... More
Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @4.5 percent by weight of total mix and filler, transporting the hot mix to work site laying with a hydrostatic paver finisher with sensor control to the required grade level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 505 complete in all respects. Grade II RCDSOR 5.04 A(B)
2548.75
-
-
... More
Providing and laying bituminous concrete with higher capacity batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment , rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 507 complete in all respects. Grade II RCDSOR 5.05 A(B)
1390.23
-
-
... More
Earthwork in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary soil. Mechanical means depth upto 3m. RCDSOR 12.01 B (i)
11290.76
-
-
... More
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. PCC Grade M15 using batching plant & concrete pump. PCC M15 RCDSOR 12.08 A Case I
2011.52
-
-
... More
Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and technical specifications. Random Rubble masonry (coursed/uncoursed) RCDSOR 13.04A
394.83
-
-
... More
Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification. RCDSOR 16.01
237.8
-
-
... More
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification. RCDSOR 16.05
53.02
-
-
... More
Laying Reinforced cement concrete pipe NP4 / prestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. 1000mm Dia RCDSOR 9.04 B
387.5
-
-
... More
Pointing with cement mortar (1:3) on brick work in substructure as per technical specifications. RCDSOR 13.02
476.77
-
-
... More
Back filling behind abutment, wing wall, return wall complete as per drawing and technical specifications. RCDSOR 13.09 A
1059.04
-
-
... More
Plastering with cement mortat (1:3) on brick work in substructure as per technical specifications. RCDSOR 13.03
141.58
-
-
... More
Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces. RCDSOR 8.08
141.58
-
-
... More
Stone masonry work in cement mortar 1:3 in foundation complete as per drawing and technical specifications. Random Rubble masonry (coursed/uncoursed) RCDSOR 12.07 B
82.34
-
-
... More
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification. RCC M25 in Deck slab Height upto 5.0m. RCDSOR 14.01B Case-1(p)
16.28
-
-
... More
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. RCDSOR 14.04
46.47
-
-
... More
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications. RCDSOR 14.02
0.85
-
-
... More
Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with Reinforced Cement Concrete with HYSD reinforcement conforming to MoRT&H specification and as per details given IRC-5 (Fig.-5, b) including dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board etc., as per approved drawing and at locations directed by the Engineer, all as specified. (Area- 0.243 sqm./meter, single face). M25 Grade Concrete RCDSOR 8.22 A (i)
309.36
-
-
... More
Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment , wing wall/ returen wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20 H towards drawing face. Complete as per drawing and technical specifications. RCDSOR 13.08
2535
-
-
... More
Providing and laying of filter media with granular materials/stones crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment , wing wall and return wall to the full height compacted to a firm condition complete as per drwaing and technical specification. RCDSOR 13.10
1957.79
-
-
... More
Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications. RCDSOR 14.17(ii)
24
-
-
... More
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight. RCDSOR 14.17(iv)
24
-
-
... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical specifications. RCDSOR 13.05 F (P)
1273
-
-
... More
Supplying, fitting and placing HYSD bar reinforcement in sub structure complete as per drawing and technical specifications. RCDSOR 13.06
116.14
-
-
... More
Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications. PCC Grade M20 using batching plant, transit mixer & concrete pump. RCDSOR 13.05 B (p)
3435.11
-
-
... More
Flexible Apron :Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall. RCDSOR 16.11
1061.7
-
-
... More
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification. RCDSOR 14.10 Case-I
176.4
-
-
... More
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. RCDSOR 14.11
352.8
-
-
... More
Drainage spouts complete as per drawing and Technical specification. RCDSOR 14.09
30
-
-
... More
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. RCDSOR 12.04
26.4
-
-
... More
Furnishing and Placing Reinforced/Prestressed cement concrete in super structure as per drawing and Technical Specification. RCDSOR 14.01 C (i) p
28.5
-
-
... More
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications. RCDSOR 12.42
8.12
-
-
... More
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. RCC Grade M20 using batching plant & transit mixer and concret pump. RCDSOR 12.08 C Case I
2353.8
-
-
... More
Retro-reflectorised traffic signs (Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of class-C type XI retro reflective sheeting fixed over 2mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25x25x3mm angle mounted on a mild steel circular pipe 65NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundatioin with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC:67) (ii) 90 cm equilateral triangle. RCDSOR 8.04 A (ii)
52
-
-
... More
Retro-reflectorised traffic signs (Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of class-C type XI retro reflective sheeting fixed over 2mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25x25x3mm angle mounted on a mild steel circular pipe 65NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundatioin with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC:67) (viii) 60 cm circular. RCDSOR 8.04A (viii)
25
-
-
... More
Retro-reflectorised traffic signs (Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of class-C type XI retro reflective sheeting fixed over 2mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25x25x3mm angle mounted on a mild steel circular pipe 65NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundatioin with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC:67) (x) 80 cm x 60 cm rectangular. RCDSOR 8.04 A (x)
11
-
-
... More
Retro-reflectorised traffic signs (Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of class-C type XI retro reflective sheeting fixed over 2mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25x25x3mm angle mounted on a mild steel circular pipe 65NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundatioin with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC:67) (xii) 60 cm x 45 cm rectangular. RCDSOR 8.04 A (xii)
20
-
-
... More
Retro-reflectorised traffic signs (Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of class-C type XI retro reflective sheeting fixed over 2mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25x25x3mm angle mounted on a mild steel circular pipe 65NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundatioin with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC:67) (xv) 90 cm high octagon. RCDSOR 8.04 A (xv)
16
-
-
... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area exceeding 0.9 sqm fixed over back support frame of min 40 x 40 x 5 mm Angle mounted on two nos. of mild steel circular pipe 65 NB, 3.2mm thickness and 4.5m meter total height firmly fixed to the ground by means of properly designed foundation with M 25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. RCDSOR 8.06
10.8
-
-
... More
Road delineators (Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide stripes, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and confirming to IRC-79 and the drawings). RCDSOR 8.15
334
-
-
... More
Solar Powered Road Marker (Solar Stud) Supplying of Solar Raised Pavement Markers made of polycarbonate molded body with circular shape, solar powered, LED self illumination in active mode 360 degree illuminatioin and reflective panesla with micro prismatic lens capable of providing total internal reflection of the light entering the lens face in passive mode. The marker shall support a load of 20000 kg tested in accordance to ASTM D 4280. The marker should be resistant to dust and water ingress according to IP 65 standards and should withstand temperatures in the range of 0 C to 70 C. Color of lighting coule be provided in red or yellow (amber) as per requirement and typical frequency of blinking in 1 Hz. There should be current losses of less than 20 microamperes at 2.4 V in sleepcharging mode to enhance the life of the marker and a full charge should provide for a miniumum autonomy of 50 hours. The height, width and length of the marker shall not be less than 10mm x 100mm x 100mm. Also, the surface diameter of the marker shall not be less than 100mm respectively. The weight of the marker shall not exceed 0.5 Kilograms. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive and complete as directed by the engineer. RCDSOR 8.35
1213
-
-
... More
Type-A "W" Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanished by hot dip process, all fittings to conform to IS : 1367 and IS:1364 metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5mm, 330 mm long complete as per clause 811). RCDSOR 8.23 A
2600
-
-
... More
Overhead signs (Providing and erecting overhead signs with a corrosion resistant aluminium alloy sheet reflectories with high intensity retro-reflecive sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 502.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel tresties and trusses of sections and type as per structural design requirements and approved plans & and as per IRC:67) Truss and Vertical Support. RCDSOR 8.07 A
4.5
-
-
... More
Fixing of Reflective sheeting including all cost of materials and fitting etc. NS
42
-
-
... More
Add 18% GST (In Basic Rate must fill 18)
12
-
-
... More
Add 1% Labour Cess (In Basic must Rate fill 1)
1
-
-
Evaluation Notes How It Works ?
Potential Partner