Rajendra Institute Of Medical Sciences Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 1,00,000Document Cost
₹ 5,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_RIMS_45734_1Bid Award Id
ViewTender No
NIT No 2899/RIMS Misc(5) dated 19-08-2020Tender Authority
Rajendra Institute Of Medical Sciences ViewPurchaser Address
-Website
http://http://www.rimsranchi.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT for supply and Installation of Fire Extinguishers at RIMS, Ranchi
Tender document for supply and installation of Fire Extinguisher at RIMS, Ranchi
BOQ Items
SITC of electric driven Pressurization/Jockey Pump suitable for automatic opertation complete as required & as as per enclosed specification and consisting of the following:
Horizontal type end suction centrifugal,Jockey pump of cast iron body and bronze impeller, with SS shaft, to ensure at highest and farthest outlet at a flow of 180 LPM & 85 m head confirming to IS-1520 complete with necessary safety relief valve, drain, pressure gauge on the delivery side , drain and bypass arrangement for testing of the working of the pumping set as required.
Suitable HP Squirrel cage induction motor suitable for operation on 415 V, 3 phase,50Hz, AC supply for the above pump with synchronous speed of 3000 RPM, IE-3, T.E.F.C. type confirming to IS - 325 with IP:55 protection for enclosure, horizontal foot mounted, class-F insulation, flexible coupling & coupling guard with the pump complete.
Common base frame shall be fabricated from MS channel / ISMB with vibration isolator. The base frame shall be held by bolts grouted in the suitable cement concrete foundation duly plastered and painted including foundation bolts, washers complete etc. as required. Approved Make: KIRLOSKAR / KSB /GRUNDFOS
1
-
-
Supply, Installation, testing and commissioning of pressure switches in MS pipe for Hydrant Electric pump/ Sprinkler Electric pump / Diesel Engine Driven Pump / Jockey Pumps, diaphragm type, adjustable range from 0-10 kg/sq.cm and a regulation range of 0.1 - 1.5 kg/sq.cm direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finish and SS316 diaphragm and other wetted parts, including necessary wiring upto control panel & other materials as required as per specifications. Approved Make: INDFOSS/DANDFOSS
1
-
-
Supplying & fixing Internal and External stainless steel single headed fire hydrant landing valve with instantaneous stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS:5290(Type-A) with blank PVC cap and chain as required. Approved Make: NEWAGE / SAFEX / SHAH BHOGILAL
1
-
-
Providing & fixing 63 mm dia stainless steel short Branch pipe with 20mm (nominal internal diameter) in size stainless steel nozzle conforming to IS:903 suitable for instantaneous connection complete to inter-connect hose pipe, coupling etc. as required and as per enclosed specification. Approved Make: NEWAGE / SAFEX / SHAH BHOGILAL
1
-
-
Providing & fixing of MS Hose cabinet outdoor type of size 0.90 Mx 0.60 Mx 0.50 M made of 2mm thick MS sheet with 6mm thick glazed glass doors i/c necessary locking arrangement suitable to accomodate 2nos 15m long hoses, one no branch pipe, etc. and mounted on wall or with raised brick platform. The cabinet shall be painted with red colour shade No. 536 of IS: 5 externally & white internally complete in all respects for external hydrant and as per enclosed specification.
1
-
-
Providing & fixing 63mm dia., 15mtr. long RRL hose pipe (ISI Marked) with 63mm dia. male and female stainless steel couplings duly binded with GI wire, rivets etc. conforming to IS- 636 (Type-A) complete as required & as per enclosed specification. Approved Make: NEWAGE / CRC
1
-
-
Providing and fixing First-Aid Hose Reel 20mm dia. x 30m long (minimum length) (Thermoplastic Type as per I.S. 12585) complete with drum, bracket, 25mm dia. shut-off valve and 5mm Gun-Metal nozzle conforming to IS-:884, connection with riser with MS C- class pipe, painting the MS works complete as required & as per enclosed specification. Approved Make: NEWAGE / SAFEX / SHAH BHOGILAL
1
-
-
Providing and fixing angle iron 40mm x 40mm x 5mm door frame and M.S. sheet (2mm thick) cum glass shutter of size 2.1M x 0.9M (N.S.) with 25mm x 25mm x 3mm angle frame all around and stiffened in between i/c hinges, handle, locking arrangement, painting with approved synthetic enamel paint i/c sign writing on glass at internal hydrant including providing & fixing S.S. sheet 2mm thick on remaining portion above door to close opening i/c painting etc. as required. Glass shall be 6 mm thick.
1
-
-
Supplying and fixing orifice plate made of 6 mm. thick stainless steel with orifice of required size in between flange & landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 kg/cm2 complete as required & as per enclosed specification.
1
-
-
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
1
-
-
Providing and fixing 4 way Gun-metal Fire Brigade inlet connection comprising of 4 nos. 63mm dia. male instantaneous inlet couplings with cap and chain as required for 150mm dia. flanged conforming to IS- 904 complete (to be connected to static tank) as required and as per enclosed specification. Approved Make: NEWAGE / SAFEX / SHAH BHOGILAL
1
-
-
Providing and fixing fire brigade suction hose coupling (draw out connection) with nut for female coupling as per IS-902 complete with 150mm dia. Suction pipe and foot valve (to be connected to static tank) complete as required and as per enclosed specification. Approved Make: NEWAGE / SAFEX / SHAH BHOGILAL
1
-
-
Supply, installation, testing & commissioning of two-way gun metal fire brigade inlet connection consisting of 63mm size instantaneously male coupling and shall be protected by cap scored with a chain glass bore etc. complete with one butter fly valve and 1 Nos non-return valve. (For external ring main, tower hydrant) Approved Make: NEWAGE / SAFEX / SHAH BHOGILAL
1
-
-
PIPES & VALVES
-
-
-
Supplying, fixing, testing and commissioning of pipes of following sizes of MS ‘C’ class along with necessary clamps, vibration isolators and fittings such as bends,tees etc..but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted and buried in ground excavation and refilling etc. as per specification and as required complete in all respect.
Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Approved Make : TATA /JINDAL / APOLLO
150mm dia. (for External)
1
-
-
80mm dia. (for External)
1
-
-
Providing, fixing, jointing and commissioning of following sizes of C- class heavy duty Mild Steel pipes conforming to IS-1239/ IS- 3589, including cutting, welding, threading,nut-bolts, gasket, fitting viz. bends, tees, reducers, crosses, flanges etc. and fixing the pipes on wall / ceiling / beam / floor with suitable MS clamps / structural supports/PCC block and painting complete as required and as per enclosed specification. Approved Make : TATA /JINDAL / APOLLO
Note:-The Pipes size 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
250mm dia.
1
-
-
200mm dia.
1
-
-
150 mm dia.
1
-
-
100 mm dia.
1
-
-
80 mm dia.
1
-
-
65 mm dia.
1
-
-
50mm dia. Threaded joint
1
-
-
40 mm dia. Threaded joint
1
-
-
32 mm dia. Threaded joint
1
-
-
25 mm dia. Threaded joint
1
-
-
Providing, fixing, testing and commissioning of following sizes of Gate Valve of rating PN 16, wafer type, in cast iron body with Ductile Iron disc, EPDM seal, SS single piece shaft, conforming to IS-13095 of the following sizes complete with cast iron hand lever companion flanges, bolts, nuts, washers & inserted rubber gaskets, as required and as per enclosed specification. Approved Make: LEADER/ZOLOTO / SANT
250mm dia.
1
-
-
200mm dia.
1
-
-
150mm dia.
1
-
-
100mm dia.
1
-
-
80mm dia.
1
-
-
65mm dia.
1
-
-
Providing, fixing, testing and commissioning of following sizes of CI non return valve conforming to API-594 with C.I. body, SS Disc, SS stem, EPDM seal, complete with companion flanges, bolts, nuts, washers & inserted rubber gasket complete as required and as per enclosed specification. (PN-16) Approved Make: LEADER/ZOLOTO / SANT
150 mm dia.
1
-
-
65mm dia.
1
-
-
Providing & fixing gunmetal gate valve with PN 16 rating with nut, bolts & washers, painting etc complete as required as per specifications. Approved Make: LEADER/ZOLOTO / SANT
25 mm nominal bore
1
-
-
Providing & fixing of 25mm dia. gunmetal air release valve with all fittings and forged ball valve on header complete as required and as per enclosed specification. Approved Make: LEADER/ZOLOTO / SANT
1
-
-
Providing & fixing of C.I double flange suction " Y" type strainer / Foot Valve fabricated out of minimum 1.2 mm thick Stainless Steel sheet with 3 mm dia. perforation holes including nuts, bolts and 3 mm thick rubber insertion complete & tested to 16 Kg/Sq.cm pressure complete as required and as per enclosed specification. Approved Make: LEADER/ZOLOTO / SANT
250mm dia.
1
-
-
100 mm dia.
1
-
-
Providing and fixing following size Pressure gauge (0-15 Kg/Cm2) complete with shut off valve duly calibrated before installation complete as required & as per enclosed specification.
150mm dia. Approved Make: H.GURU / FEIBIG
1
-
-
Providing, fixing, testing & commissioning of MS air cushion tank on top of each riser fabricated from 6mm thick MS plate, 200 mm in diameter and 1.2 m in height with dished ends fabricated from 8mm thick MS plate with Air release valve with stop cock, flanged inlet connection and drain arrangement with 25mm dia valve, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS 4736-1968.
1
-
-
Providing, fixing & installation of control valve (Sprinkler Alarm Valve) of Cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases ,strainer, pressure switch, cock valve complete with drain valve and bypass, test control box,ball valves, flanges, orifice plate, fittings, gasket etc.suitable for 150 mm diameter pipe size complete as required as per enclosed specification. Approved Make: HD / NEWAGE
1
-
-
Air pressure vessel for Fire Pump :-Providing and fixing double flanged vertical air vessel fabricated from 6mm M.S. plate with dished ends from 8mm M.S. plate, outside with one coat of primer and two coats of synthetic enamel paint of approved shade, complete with approved quality of pressure switches (03 Nos.), pressure gauges and all other required accessories to operate commonly main fire pump, sprinkler pump, Diesel Fire pumps and Jockey pumps at drop of pressure automatically at required pressure setting complete as required and as per enclosed specification.
Recommended dia. : 250mm
Height of shell : 2000mm
Working pressure :12 Kg/Sq.cm
Test Pressure : 16 Kg/Sq.cm
1
-
-
Providing and fixing reinforced neoprene rubber vibration eliminators/expansion joints (to provide relief from stresses at pipe flanges) suitable for upto 20 kg/cm2 pressure, complete as per specification. Approved Make : KANWAL / EASYFLEX / METRAFLEX
150mm dia.
1
-
-
100mm dia.
1
-
-
80mm dia.
1
-
-
PIPES & VALVES
-
-
-
Providing & fixing of 15 mm dia. sprinkler head with standard response Quartzoid Bulb operate at 68 degree C complete with all accessories as required and as per enclosed specification (UL Listed) Pendent type in chrome finish (Standard Coverage) Approved Make: HD / TYCO/VKING/NEWAGE
1
-
-
Providing & fixing flexible tubes in corrugated SS, for connecting pendant sprinklers to branch lines complete with all necessary accessories, reducers, O-rings, nipples etc., supporting structural arrangments in the false ceiling/slab as per site requirement for the below lengths and tested for min 15 Kg/Sq.cm pressure with G.I. retainer rings & guide bolts complete as required and as per enclosed specification (UL Listed) For 1000 mm length Approved Make: HD / TYCO / NEWAGE
1
-
-
Providing and fixing electrically operated flow indicating switches Vane type with threaded connection for indicating water flow in sprinkler branch line with necessary junction box installed in accessible place. including cost of cable etc. complete. (Wiring from switches to panel and stair-case pressurisation not included). Approved Make: HONEYWELL / SENSOTRONIC SYSTEM/ SWITZER
150 mm Dia
1
-
-
100 mm Dia
1
-
-
80 mm Dia
1
-
-
65 mm Dia
1
-
-
Providing and fixing 25mm dia inspecting & testing assembly with S.S. isolation valve, S.S. sight glass byepass valve & connected to line drain complete in all respect as per standard practice of code including pressure gauges of approved make. Approved Make: RELIABLE / HD / UL LISTED
1
-
-
FIRE EXTINGUISHER
-
-
-
Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and wall suspension braket as required as per specifications. Approved Make: MINIMAX / SAFEX / CEASE FIRE / SAFEGUARD
1
-
-
Supply, installation, testing and commissioning ISI marked (IS:15683) portable fire extinguisher, water (gas pressure) type capacity 9 kg with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets as required as per specifications. Approved Make: MINIMAX / SAFEX / CEASE FIRE / SAFEGUARD
1
-
-
Supply, installation, testing and commissioning of 6kg ABC (Powder Type) Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 as required as per specifications. Approved Make: MINIMAX / SAFEX / CEASE FIRE / SAFEGUARD
1
-
-
Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked / approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:910 50 Litres (trolley mounted) Approved Make: MINIMAX / SAFEX / CEASE FIRE / SAFEGUARD
1
-
-
ELECTRICAL SYSTEM
-
-
-
Supply, installation, testing and commissioning of the fire pump control panel, front operated cubicle construction, Floor mounted type, fabricated out of 2mm thick CRCA Sheet, Compartmentalized with hinged lockable doors, dust and vermin proof, Powder coated of approved shade after 7 tank treatment, Cable alley, inter-connections, having Switch gear and accessories mounting, internal wiring, earth terminals, Top/ Bottom cable entry, numberings etc. suitable for operation of 415 volts, 3 phase 4 wire 50 Hz AC Supply with enclosure protection class IP 42 complete as required and as as per enclosed specification with the following:
INCOMER - 2No.
- 630 Amps, Four pole, 35 KA MCCB with rotary handle on door.
- Digital Voltmeter (0-500 Volts) with selector Switch & protected by MCB.
- Digital Ammeter (0-630 Amps) with selector Switch & CT's etc.
- Set of (R,Y,B) LED phase and ON / OFF indication Lamps protected by MCB.
Buscoupler
1 No. 630 Amp 4P MCCB (Icu=Ics value 35KA) .
1 Set of ON LED type indication lamp controlled by 2 Amp SP MCB.
Including all features of electrical & mechnical interlocking with incomers & bus coupler. BUSBAR
- 1 Set of 800 Amps 4P Aluminium
OUT GOINGS
For Main fire pump -2 Nos.
- 200 Amps. 4P MCCB ( Motor Duty) 35 KA with rotary handle on door.
- Digital Ammeter (0-200 Amps) with selector Switch & CT's etc.
- Set of LED ON / OFF indication Lamps protected by MCB.
- Suitable HP fully automatic Star delta starter with over load protection & current sensing type single phase preventor complete with all accessories and internal wiring for automatic operation.
Note: All MCCBs should be 4 pole with Icu = Ics value 35 KA.
1
-
-
Set of Selector switches for Auto / Manual /OFF operation.
Set of ON & OFF Push Buttons
For Jockey pumps -2 No.
40 Amps.4P MCCB, 35 KA (motor duty) with rotary handle on door.
Digital Ammeter (0-40 Amps) with selector Switch & CT's etc.
Set of LED ON / OFF indication Lamps protected by MCB.
Suitable HP fully automatic DOL starter with over load protection & current sensing type single phase preventor complete with all accessories internal wiring for automatic operation.
Set of Selector switches for Auto / Manual / OFF operation.
Set of ON & OFF Push Buttons. Diesel Engine Control-1No.
Auto / Manual selector switch & 3 attempt starting device ,timers and relays, push buttons,start / stop in manual mode etc.
LED Indication lamp for High / Low Lub.oil pressure , High Water Temp and Engine ON indication.
Battery charger suitable for 12/24V DC ,180AH with boost and tickle circuits,selector switches, 0-30 V DC Voltmeter , 0-20 Amp DC Ammeter etc.
All standard relays and accessories for automatic operation of diesel engine.
NOTE :
1. All MCCB shall have 100% Ics =Icu
2. Low water level indication in fire tank should be interlocked with centralized PLC control panel.
1
-
-
Providing and fixing complete CO2 flooding system of approved make and model for main LT panel including two nos. 22 kg seamless cylinder required quantity of MS seamless pipe, manifold, NRV, high pressure flexible hose, weighing arrangement, pneumatic valve, CO2 nozzles including painting and MS support.The size of main LT panel will be as per Electrical scope of work. The shop drawing/datasheet of CO2 flooding system shall be provided by Agency for approval of HSCC before start of the work. The CO2 flooding panel shall also meet out the local Fire Officers latest requirement and anything extra or any modification required by Fire Officer shall be carried uot by Agency without any extra cost.
1
-
-
Supression System
-
-
-
S/F 10 LB capacity NOVEC 1230 DLP Assembly with Automatic valve, push in connector for tube, 5 LB NOVEC 1230 gas, mounting bracket, end of line adopter and low pressure switch for monitoring system activation of automatic linear pneumatic tube detection system complete etc. as reqd as one job Approved Make: Fire Trex /Seimens / UTC
1
-
-
S/F 2.5 LB capacity NOVEC 1230 DLP Assembly with Automatic valve, push in connector for tube, 2.5 LB NOVEC 1230 gas, mounting bracket, end of line adopter and low pressure switch for monitoring system activation of automatic linear pneumatic tube detection system, complete etc. as reqd as one job Approved Make: Fire Trex /Seimens / UTC
1
-
-
S/F linear pneumatic heat detection tube UL marked and suppression system operated on 92-100 deg, Cent temp. With all necessary fittings and supports, fixing in the existing electrical panel board, complete etc as required at site . Approved Make: FireTraco/Srevo System/Fire System/Fire TEC
1
-
-
S/F audio visual alarm system for automatic linear fire trace tube detection system, complete etc as required at site
1
-
-
Providing and fixing horizontal centrifugal end suction single/multi stage, single/multi outlet pumping set with bronze impeller with C.I. body and connected by a flexible coupling to a totally enclosed fan cooled induction motor (IE 3 class) mounted on a common structural base plates with all pump accessories complete as per specifications including pressure gauges with gunmetal isolation valves and anti vibration pad, motor to be suitable for 415 volts, 3 phase, 50 cycles A.C. supply (Specifications as per fire fighting requirements and on the pattern of TAC or local authority approval) as per instruction and following specifications: (All pumps shall have mechanical seal) Approved Make: KIRLOSKAR / KSB / GRUNDFOS
1
-
-
Fire Terrace Pump
Type : End suction
Speed (rpm) : 2900
Capacity : 900 lpm
Head : 35Mtr.
1
-
-
Providing, fixing, testing and commissioning of control panel for Terrace Booster pumps .
Incoming: MCCB 35A 1 set of Phase indicating lamps, 1 set of 35A Al bus bars, 1No Ammeter, 1No Voltmeter with phase selector switch Feeder for Booster Pumps - 1 No. 1 No. 32A TP MCCB without releases. DOL starter with over load relay, single phase preventor and indicating lamps with ON/OFF push buttons. 1 No. Automanual selector switch. Suitable for booster pumps
Water Reservoir 1.00 L
1
-
-
FIRE ALARM AND DETECTION WORKS
-
-
-
Supply, Installation, Testing & Commissioning of Networkable (upto 4kms) Microprocessor based intelligent analog Addressable Type Fire Alarm Control Panel of 2 loop, with minimum 320 character graphics / LCD / LED display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM) ,The panel should be equiped with loop capacity to take minimum 240 intelligent addressable detectors/ devices (In any combination ) in one loop. Four access levels, capable of taking Protocol Devices, Graphical Display, sufficient number of programmable relay controls for controlling pressurization fans, ventilation fans, fire pump room, monitoring of fire sprinkler and fire hydrant pump etc, suitable for operation at 230 volts, 50 Hz AC power supply including automatic battery charger, 24 volts sealed maintenance free lead acid batteries sufficient for 2 hours normal working and shall be capable of operating the system for 30 minutes during an emergency / fault conditions in addition as required. The panel shall be UL/EN listed (Latest Version) and shall be interfaced with PA system. (For Giving trigger Signal to Start pre-recorded Digital Voice Evacuation from PA system in case of fire ). It shall have interfacing connectivity (BACNET/ MODBUS/ Open protocol gateway) for Building Management System complete as required. Approved Make: GST / NOTIFIRE / MORLEY
1
-
-
Supply, Installation, Testing & commissioning of UL/EN listed (latest version) intelligent addressable multi criteria detector {Smoke + heat } with inbuilt fault isolator / isolator base and with unique optical sensing chamber, visible LED, fully coated circuit board, superior RF / Transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) c omplete with connections etc. as required and to be installed below / above false ceiling, roof and concealed space and as per enclosed specifications. (Cost of plug in common base shall deemed to be included in cost of detectors) Approved Make: GST / NOTIFIRE / MORLEY
1
-
-
Supply, installation, testing and commissioning of UL/EN listed (Latest Version) intelligent A ddressable type Heat Detector (Fixed cum-rate of rise type) with inbuilt fault isolator / isolator base w ith range upto 57° C complete with all fixing accessories like base, base box, self adhesive sticker indicating loop number and address etc. to be installed below / above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required. Approved Make: GST / NOTIFIRE / MORLEY
1
-
-
Supply, installation, testing and commissioning of UL/EN listed (latest version) Intelligent addressable Control Module/ Relay Module (output module) with inbuilt fault isolator or isolator module for tripping of AHU & Ventilation / pressurisation fans / hooter complete with termination etc. as required and as per enclosed specifications. Approved Make: GST / NOTIFIRE / MORLEY
1
-
-
Supply, installation, testing and commissioning of Response Indicator for getting fire indications of detectors installed above false ceiling area interconnecting to loop cable complete as required.
1
-
-
Supply, Installation, Testing & commissioning of UL/EN listed (latest version) intelligent addressable Manual call station (pull type) suitable for semi flush mounting with inbuilt fault isolator / isolator module with double gang outlet box, equipment for key operated test-reset lock, electronic or rotary switches for address setting. Manual pull station shall be connected with two wire to SLC loop of Fire Control Panel. Cover shall be made out of LEXAN (or poly carbonate) with clear operating instruction and the word "FIRE" appearing on the front complete with connections etc. as required and as per enclosed specifications. Approved Make: GST / NOTIFIRE / MORLEY
1
-
-
Supply, installation, testing and commissioning of UL/EN listed (latest version) loop powered addressable Hooter- cum- strobe with inbuilt fault isolator / isolator module with minimum 110 dB output at a distance of 1 mtr. complete with termination etc. as required and as per enclosed specification. Approved Make: GST / NOTIFIRE / MORLEY
1
-
-
Providing, installation, testing & commissioning of UL/EN listed (Latest Version) Monitor Module with inbuilt fault isolator / isolator module (for monitoring different electrical/mechanical device etc) as per specifications. Approved Make: GST / NOTIFIRE / MORLEY
1
-
-
Supplying, installation, testing & commissioning of UL/EN listed (Latest Version) addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required. Approved Make: GST / NOTIFIRE / MORLEY
1
-
-
Supplying, installation, testing & commissioning of UL/EN listed (Latest Version) intelligent addressable photoelectric duct detector for high dusty areas like AHUs/ventilation rooms to be installed in duct etc. interconnecting to loop cable complete with base as required. Approved Make: GST / NOTIFIRE / MORLEY
1
-
-
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. Approved Make: KEI / POLYCAB / PHENOLEX
1
-
-
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. (For FDA,Electrical and HVAC)