Power Grid Corporation Of India Limited Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 1,03,000Document Cost
Refer DocumentsTender Fee
₹ 2,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
23851Tender No
ER1/NT/S-MISC/DOM/D01/23/11902Tender Authority
Power Grid Corporation Of India Limited ViewPurchaser Address
-Website
http://https://www.powergridindia.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-all work up to plinth level.1:2:4(1 cement:2 coarse sand:4 graded stone aggregate 40mm nominal size)
0.04
-
-
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, finishing and reinforcement-all work up to plinth level.1:1.5:3(1 cement:1.5 coarse sand:3 graded stone aggregate 20mm nominal size)
18
-
-
Reinforcement cement concrete work in roof beams,suspended floors,roofs having slope upto15 degree, landings, balconies,shelves,chajjas,lintels,bands,plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centring,shuttering,finishing and reinforcement with 1:1.5:3 (1 cement:1.5coarse sand:3 graded stone aggregate 20mm nominal size).
-
-
-
Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses,plinth and string courses, fillets, columns, pillars, piers, abutments,posts and struts etc. upto floor five level excluding cost of centring, shuttring,finishing and reinforcement.
1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
7.18
-
-
Reinforcement fo R.C.C work including straightening,cutting,bending placing in position and binding all complete. Themo-mechanically treated bar
2307.22
-
-
Centering & Shuttering including
-
-
-
Foundation,footings,bases of columns etc.for mass concrete
81.62
-
-
Columns, Pillars, Piers, Abutments, Posts, Strus
7.18
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
31.56
-
-
Wall(any thickness) including attached pilasters, butteresses, plinth & string courses etc.
25
-
-
Weather shade,Chajjas,corbels etc.,including edges
-
-
-
Brick work with F.P.S bricks of class designation 75,in superstructure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6(1 cement:6 coarse sand)
7.16
-
-
6mm cement plaster to ceiling of mix: 1:3(1 cement: 3 fine sand)
95
-
-
12mm cement plaster of mix: 1:6 (1 cement: 6 coarse sand)
284.59
-
-
Supplying and stacking of hard stone (for stone pitching) 22.5 cm thick at site.
86.56
-
-
Dry stone pitching 322.5 cm thick laid in courses and required prifile with hammer dressed stones having no side less than 15 cm with minimum depth 20cm including preparing the badding surface etc.all complete (payment for stone to be made separately)
18.05
-
-
cement plaster skirting up to 30 cm height with cement morter 1:3 (1 cement: 3 course sand) finished with a floating coat of neat cement 18 mm thick
10
-
-
Providing wood work in frames of doors, windows,clerestory windows and other frames wrought anf fixed in position with hold fast lugs or with dash fasteners of required dia & length( hold fast lugs or dash fasteners shall be paid for separately)sal wood
0.15
-
-
Providing and fixing ISI marked flush door shutters non-decorative type,core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face neneers on both faces of shutters: 35 mm thick including anodised aluminium butt hinges with necessary screws.
5.2
-
-
Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/ appropriate Z section and other section of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size including necessary filling up the gaps at junctions i.e at top bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and joined mechanically whereever required including cleat angle, aluminium snap beading for glazing /paneling, C.P. brass /stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge.( Glazing,paneling and dash fasteners to be paid for separately):
-
-
-
For shutters of doors, windows & ventilaors including providing & fixing hinges/pivots and making provision for fixing of fitings wherever required including the cost of EPDM rubber /neoprene gasket required(fittings shall be paid for separately) anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade AC 15)
610
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Neoprene gasket etc. complete as per the architectural drawing and the direction of engineer-incharge. (cost of aluminium snap bading shall be paid in basic item.)
-
-
-
With glass panes of 5.50 mm thickness(weight not less than 13.75 kg/sqm)
34.5
-
-
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete fixed toopening/wooden frames with rawl plugs screws etc.
810
-
-
Providing and fixing aluminium sliding door bolts, ISI marked anodised(anodic coating not less than grade AC 10 as per IS :1868),Transperent or dyed to required colour or shade with nuts and screws etc. complete :
-
-
-
300X16mm
4
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868)transparent or dyed to required colour or shade with necessary screws etc. complete:
-
-
-
300x10mm
2
-
-
Providing and fixing aluminium pull bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868)transparent or dyed to required colour or shade with necessary screws bolts nut and washers etc. complete:
2
-
-
Providing and fixing aluminium handles ISI marked anodised (anodiccoating not less than grade AC 10 as per IS: 1868)transparent or dyed to required colour or shade with necessary screws etc. complete:
125mm
-
-
-
100mm
48
-
-
supply and fixing rolling shutters of approved make made of required size M.S. laths interlocked together through their entire length and joined together at the end by end locks, mounted on specially designed pipe shaft with nrackets,side guides and arrangements for inside and outside locking with push and pull operation complete,including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454-part 1 and M.S. top cover of required thickness for rolling shutters.
80X1.20 mm M.S. laths with 1.20 mm thick top cover
48
-
-
Extra for providing mechanical device and crank operation for operating rolling shutters. Exceeding 16.80 sqm in area
48
-
-
steel works in built-up tubular (round square or rectrangular hollow tubes)trusses including cutting,hoisting fixing in position and applying a priming coat of approved steel primer,welded and bolted including special shaped washers etc. complete
-
-
-
Hol finished seamless type tubes
15000
-
-
Providing and fixing colour coated durashine roof profile sheet of nom. 1015 mm effective cover width and nominal 28 mm deep ribs with subtle square fluting in the five pan at nominal 203 mm centre to centre. The end ribs shall be designed for anti-capill.
380
-
-
Finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade:
-
-
-
New work (two or more coats applied@ 1.46 kg/10 sqm )over and including base coat of waterproffing cement paint snowcem plus or equivalent applied@ 2.20 kg/10sqm.
630
-
-
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade
-
-
-
New work (two or more coats )over and includingpriming coat with cement primer.
405
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
-
-
-
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and anufacture.
187
-
-
Providing and fixing circular/hexagonal M.S sheet ceiling fan box with clamp of internal dia 140mm,73 mm height,3mm thich rim, top and bottom lid of 1.5mm M.S sheet. Lida shall be screwed into M.S box by means of 3mm round headed screws,clamps shaall be made of 12 mm dia M.S Bar bent to shape as per standard drawing with over all length as 80 cm.
13
-
-
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, lerraces/sunken slabs etc. consisting of following operations.
-
-
-
Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS:2645 and approved by engineer-in-charge over the RCC slab including adjoining walls up to 300mm height including cleaning the surface before treatment.
Laying brick bats 25mm to 115mm size with 50% of cement morter 1:5 (1 cement: 5 coarge sand) admixed with proprietary water profing compound conforming to IS: 2645 over 20mm thick layer of cement morter of mix 1:5 (1 cement: 5 coarse sand) admixed with propietary water proofing compound conforming to IS:2645 and approved by engineer-in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of junctions to walls and slabs.
-
-
-
After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conforming to IS:2645 and approved by Engineer-in-charge
-
-
-
Finishing the surface with 20mm thick jointless cement morter of mix 1:4 (1 cement: 4 coarse sand) admixed with proprietary water proofing compound conforming to IS:2645 and laying approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowelwith neat cement slurry and making pattern of 300X300mm square 3mm deep.
-
-
-
The whole terraceso finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-charge.
-
-
-
The whole twrrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer-in-charge.
-
-
-
With average thickness of 120mm and minimum thickness at khurra as 65mm
143.4
-
-
Making khurras 45X45 cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20mm nominal size) over P.V.C sheet 1mX 1m X400 micron, finished with 12mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outer complete.
3
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A. Including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.
23
-
-
Providing and fixing on wall face unplasticide-PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A. Including jointing with seal ring conforming to IS: 5382,Leaving 10mm gap for thermal expansion,110 mm bend
3
-
-
Provididng and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised-Rigiing PVC rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Shoe(plain)110 mm shoe
3
-
-
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50mm hard wood plugs,screwed with M.s screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement:4 coarse sand) and making good the wall etc . complete.110mm
29
-
-
Making plinth protection 50mm thick of cement concrete 1:3:6(1 cement:3coarse sand:6 graded stone aggregate 20mm nominal size) over 75mm bed on dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
30
-
-
DESCRIPTION OF ITEM
-
-
-
Point wiring in PVC conduit, with modular type switch: Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm FR LS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group C
58
-
-
Power plug wiring in PVC conduit (2x4 sq. mm) : Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 no. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
80
-
-
Circuit/ sub main wiring in PVC conduit : Wiring for circuit/ submain wiring alongwith earthwire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
-
-
-
2x1.5 sq. mm. + 1x1.5 sq. mm. earth wire
50
-
-
2x2.5 sq. mm. + 1x2.5 sq. mm. earth wire
240
-
-
2x6 sq. mm. + 1x6 sq. mm. earth wire
30
-
-
4x10 sq. mm. + 2x6 sq. mm. earth wire
25
-
-
Telephone wiring in existing conduit : Supplying and drawing following pair, 0.5 sq. mm FR PVC insulated copper
-
-
-
2 Pair
50
-
-
S/F PVC conduit : Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess
-
-
-
20 mm
50
-
-
S/F modular type switch/ socket : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
5/6A switch
6
-
-
3 pin 5/6 socket outlet
6
-
-
Telephone socket outlet
2
-
-
S/F modular boxes,base & cover plate : Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess as required.
-
-
-
1 or 2 Module ( 75 mmx 75 mm)
3
-
-
S/F modular boxes,base & cover plate : Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess as required.
10
-
-
S/F light plug point modular type accessories : Suppling and fixing suitable size GI box with modular plate & cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet amd 5/6 amps modular switch , connection, painting etc. as required. (For light plugs to be used in non residential buildings).
4
-
-
S/F light plug point modular type accessories : Suppling and fixing suitable size GI box with modular plate & cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet amd 15/16 amps modular switch, connection, painting etc. as required.
4
-
-
S/F Ceiling rose; supplying and fixing 3 pin,5 amp. Ceiling rose on the existing junction box/wooden block including connection etc,as required.
50
-
-
Supplying and fixing stepped type electronic fan regulator on existing modular plate switch box including connections etc. as required.
4
-
-
S/F Holder: supplying and fixing brass batten/ angle holder including connection etc as required.
8
-
-
Installation Testing and commissioning of prewired, fluorescent fitting/compact fluorerscent fitting af all types. Complete with all accessories and tube etc, directly on ceiling/wall including, connection with 1.5sqmm FRLS Insulated, copper conductor,single core cable, and earthing etc as required.
52
-
-
Supply and fixing of 20W CFL lamp in exising electrical fitting/fixture etc. as required.
8
-
-
Supplying fitting and fixing single wall mounted 20/22 watt LED type batten fitting complete with electronic driver and LED tube etc. directly on wall/ceiling including connection with 1.5 sq mm FR PVC insulater copper conductor and earthing the body etc.
40
-
-
Supplying fitting and fixing single 40/45 watt LED type Street light with die cast aluminium housing for ingres protection of IP65 and complete with all accessories etc. on pole/building including connection with 1.5 sq mm FR PVC insulator copper conductor and earthing the body etc.
6
-
-
Supply and Installation of 400mm,230V AC wall/cabin fan including fixing the bracket, making connection , testing ,commissioning etc as required.
1
-
-
Supplying and Installation of regular/standard model ceiling fan of 1200mm sweep including wiring of down rods of standard length (up to 30cm) with 1.5 sq mm FRPVC Insulated copper conductoer cable as required.
4
-
-
S/F TCP MCB DB: Supplying and fixing following way, three pole and neutral, sheet steel,MCB distribution board ,415
-
-
-
4 Way (4+12) Double door, horizontal type
1
-
-
12 Way Double door SPN DB
1
-
-
S/F 'C' Series SP MCB: supplying and fixing 5 amps to 32 amps rating , 240 volts c series miniature circuit breaker
-
-
-
single pole
24
-
-
S/F SPN RCCB: Supplying and fixing following rating,double pole,(single phase and neutral) 240 volts residual current circuit breaker (RCCB) having a sensitivity current upto 300 milliampere in the existing MCB DB complete with 63 amps
1
-
-
S/F TPN RCCB Supplying and fixing following rating, four pole (three phase and neutal) 415 volts residual current.
-
-
-
63 amps
1
-
-
Providing and laying earthing connection from earth electrode with 6 SWG dia G.I wire in 15mm dia GI Pipe earh electrode as required, all complete as per specification and direction of E/I.
30
-
-
Earthing with GI earth pipe 4.5 mtr long, 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.
6
-
-
Earthing with G.I earth plate 600mm x 600mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe of 2.7 meter lomg etc, with charcoal/coke salt as required.
2
-
-
Supplying and fixing 25x5mm G.I. strip in 40mm dia G.I. pipe from earth electrode all complete as per specification and direction of E/I.
12
-
-
Supplying and laying following sizes and core PVC /XLPE insulated PVC sheathed, Heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (conforms to IS:1554, PART-1)
-
-
-
50 sq. mm , 3.5 core
100
-
-
supplying & fixing panel mounted 4 pole on load change over switch 100A inside the existing cubicle panel board, including drilling holes in cubicle panel, including connections etc. as required
1
-
-
supplying & fixing wall/ floor mounted cubicle panel board, fabricated with 16 gauge iron sheet suitable for panel mounted switch disconnector including busbar chamber, insulator and painting etc. as required (but without busbar)
12
-
-
Providing and fixing following rating and capacity four pole MCCB in existing panel board, including drilling holes in cubicle panel, making connections etc. as required
-
-
-
100A 30KA
1
-
-
Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty complete with, INDICATOR LIGHT, VOLT AMMETER METER, all accessories including connections, earthing the body etc. as required.
-
-
-
200 amps
1
-
-
S/F TPN: Supplying and fixing following rating, four pole MCB, (three phase and neutral) 415 volts, in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
32A
1
-
-
S/F TPN isolator: Supplying and fixing following rating, four pole, (three phase and neutral) 415 volts, in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
100A
2
-
-