Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Patliputra Medical College And Hospital Tender

Goods
Eprocure
Opening Date11 Jul 2018
Closing Date7 Aug 2018
Tender Amount₹ 1,00,00,000 
Notes
Download

Costs

Summary

Purchase of Machine Eqipment for Central Research Lab

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Binocular Microscope - Optical system should have UIS2 (Universal Infinity System) Illumination should be System Built-in transmitted illumination system 6 V 20 W halogen bulb, 100-240 V 50/60 Hz universal voltage Focusing should be Stage height movement (coarse movement stroke 20 mm) Fine focus graduation should have 2.5 μm Revolving Nosepiece : Fixed quadruple nosepiece Stage : Wire movement mechanical fixed stage: 120x132 mm Traveling range: 76 mm (X) x 30 mm (Y) Single specimen holder Observation Tube : 30° inclined binocular tube Interpupillary distance adjustment range 48–75 mm Objective : Plan Achromatic objectives (anti-fungus) 4x N.A.: 0.10 W.D.: 18.5 mm 10x N.A.: 0.25 W.D.: 10.6 mm 40x N.A.: 0.65 W.D.: 0.6 mm 100x N.A.: 1.25 W.D.: 0.13 mm Eyepiece : (10x) Field Number (F.N.): 20 (anti-fungus) Condenser : Abbe type with aperture iris diaphragm N.A.: 1.25 Optional Accessories must be Mirror unit, 15x eyepiece (F.N. 12, anti-fungus), micrometer, filter holder, dark field stop, Micro image projection system, Phase-contrast Attachment/10X, 40X, Simple Polarizing attachment.

1

-

-

... More
Trinocular Microscope - Optical system should have UIS2 (Universal Infinity System) Illumination should be System Built-in transmitted illumination system 6 V 20 W halogen bulb, 100-240 V 50/60 Hz universal voltage Focusing should be Stage height movement (coarse movement stroke 20 mm) Fine focus graduation should have 2.5 μm Revolving Nosepiece : Fixed quadruple nosepiece Stage : Wire movement mechanical fixed stage: 120x132 mm Traveling range: 76 mm (X) x 30 mm (Y) Single specimen holder Observation Tube : 30° inclined binocular tube Interpupillary distance adjustment range 48–75 mm Objective : Plan Achromatic objectives (anti-fungus) 4x N.A.: 0.10 W.D.: 18.5 mm 10x N.A.: 0.25 W.D.: 10.6 mm 40x N.A.: 0.65 W.D.: 0.6 mm 100x N.A.: 1.25 W.D.: 0.13 mm Eyepiece : (10x) Field Number (F.N.): 20 (anti-fungus) Condenser : Abbe type with aperture iris diaphragm N.A.: 1.25 Optional Accessories must be Mirror unit, 15x eyepiece (F.N. 12, anti-fungus), micrometer, filter holder, dark field stop, Micro image projection system, Phase-contrast Attachment/10X, 40X, Simple Polarizing attachment.

1

-

-

... More
Hot air oven digital size14x14x14 inner chamber SS and outer body alluminium finished in powder paint.

1

-

-

... More
Microtome - Serial sectioning adjustable from 1 to 50 microns in step of 1 micron wih accessories.

1

-

-

... More
Electronic weight balace - 5mg to 100 gms capacity Digital

1

-

-

... More
Tissue floating bath - Round, double walled, single piece inner and outer chamber are made of alluminium. Inside black and outer surface finished in powder paint.

1

-

-

... More
565 litre Frost free refrigerator - Frost free side-by-side: Auto defrost to stop ice-build up capcity 500 to 650 ., Separate temperature control, 2 independent cooling system, vitafresh plus, Digital display and control, 3 large crisper box, Multi-airflow.

1

-

-

... More
370 Litre chest freezer (0º to-70º c) good quality

1

-

-

... More
water bath with temperature range 5º c above ambient to 100º c (capacity 32 litre)

1

-

-

... More
Bio safety cabinet Class II type A2 - size: the width of working sapce should be at least 1.2 meters (4 feet). Efficiency should be ≥99.99% inhibiting particles ≥ 0.3 µm with ULPA/HEPA filter., Should be able to provide about 70% air to recirculate and 30% exhaust., Should be vibration free and low noise working station., Should be ISO certified., Cabinet should have Fluorescent and Germicidal UV lamps with automatic control. Bio safety cabinet should have internally electrical socket outlet, and fitting for vacuum., Differential pressure gauge should be there., This equipment should be supplied with a compatible UPS with at least 20-25 minutes backup., It should be provided with support stand, castor wheels, fixed foot or foot masters. and Installation, demonstration/ technical presentation should be conducted.

1

-

-

... More
Microwave Oven Capacity – 30 ltr., lock, overheating protection, defrost, steam cleaning, Temperature setting, Digital type control & Stainless steel body. Central type- digital, Temp setting, defrost,stem cleaning.

1

-

-

... More
Spectrophotometer Spectral slit width max. 2nm., Wavelength required range – Full uv/visible range in normal but at least 400-700nm., Accuracy ± 1 nm., Precision ± 0.5nm., Photometric., Absorbance range – 3A. Accuracy ± 2% max. ± 1% over as much range is possible.,

1

-

-

... More
Water purification system (Millipore with pre purification & softener) Product water –TOC ppb ˂30., Product water resistivity in (C25ºC) -75-15% pure water 75., Feed water nature- tap water., conductivity ˂0.2., Product water volume : ˃5.25l/day:˃25-100 l/day., Silica removal (%) ˃99.9., Micro or ganism cfu/ml: ˂1., System recovery, nominal flow.

1

-

-

... More
Horizontal - Autoclave - High pressure autoclave 1.2kg/cm2 i.e. 121 degree C., Inner chamber stainless steel 316 grade., outer chamber stainless steel 304 grade., Jacket of best quality steel., Chamber diameter 400mm., Chamber depth 600mm., steam trap., Steam generator feed water pump.,Self locking safety door., Tight sealing door gasket(Gasket of heat resistant material silicon/EPDM). Drain temp. gauge. , Vaccum breakers., Safety valve for jacket., Pressure switchers, Pressure gauge., Low water protection system(Automatic)., Digital Temp. indicator., Micro processor based Automatic System ., Should carry ISI/BIS mark., Provision for vaccum drying., Power requirement 440volts(Three phase)., Should be mounted on a stand which is resistant to corrosion., Should have a report to hydraulic testing., Working principal -Downward displacement of air.,

1

-

-

... More
Table top non refrigerated centrifuge

1

-

-

... More
Table top refrigerated centrifuge -Must have wide temp. range (3Cto +40 C) of operation., it shold supplied with aat least three rotors 1) Fixed angel rotor accommodating at least 24x1.5/2 ml tubes (can go upto a speed approximately 14500rpm or 23000g). 2) Fixed angel rotor accommodating at least 6x15/50 ml ( can go at a speed of approxmately 7000xg) and 3) a cell culture plate/plate rotor (can go at a speed of approximately 2000xg)., it should have an option to accelerate the speed at various rates., Noise level should be less than 60db. Must be supplied with compatible wall mountable stabilizer.three years warranty and on site repair services and required., Year-wise Installation details for last 10 years.,

1

-

-

... More
Table top refrigerated Ultracentrifuge

1

-

-

... More
Microscope (Fluorescent)High power LED adjustable intensity & integrated diaphragm travel range 76mmx25mm with vernier reading., 3W LED with four filter blue, green, violet and ultra violet., Life expectancy of LED is around 30000 hrs. no replacement required., Condenser – Universal turret (5 position) type condenser (NA 1.1 or better) for BF/DF/Pn and polarizing., Objective – Achromatic phase objective (10x/0.25 WD 10.6 mm; 20x/0.4WD 1.2mm; 40x 0.75 WD 0.51 mm; 100x/1.30WD 0.2 mm or better; 4x objective) .

1

-

-

... More
Refrigerator Double door 300 ltr. Capacity, 4-5 star rating

1

-

-

... More
Fully Auto Clinical Chemistry analyser Should have Random access, fully automated. 100 tests per hour. Up to 28 onboard chemistries Automatic probe cleaning, liquid level detection & collision protection Automatic dilution for abnormal sample Bi-directional LIS interface Measuring principles should have Absorbance photometry, turbidimetry, Methodology should have End point, fixed-time, kinetic,optional ISE Reaction rotor should have Rotating tray, containing 40 cuvettes, reusable Cuvette should have optional length 5mm Reaction Volume should have 180-500ul Reagent/Sample tray should have 28 positions for reagents and 8 position Should have Computer set, Online 2KVA UPS and standard Accessories with startup reagents. Complete training on handling the instrument, programming interpretation has to be given free of cost by the supplier. Brochure should be attached of the Equipment and demonstration for final consideration.

1

-

-

... More
Digital PH meter Digital pH/mV meter Specifications Requirement Application For research with a comprehensive range of features and functions, making it suitable for general laboratory, QC and GLP based applications. . Unit Consisting of Tri-combination pH/ATC electrode with an electrode holder/arm with smooth movement and protection cover ., . Working pH Range 0 – 14 pH., pH resolution ± 0.01 pH.,. Mv • Range 0 - ± 1999 • Accuracy± 1mV • Resolution 1 mV ., Temperature Compensation 0 to 100 ° C with ATC ., Temperature Range -10 to +105°C Resolution 0.1°C Accuracy ±0.5°C ATC range 0 to 100° .,. Calibration Points • Should have 3 stage calibration with auto buffer recognition • NIST traceable buffer set 500 ml each (pH 4.0, 7.0 & 9.0)..,. Alarm • Calibration reminder interval (1 to 999hrs) ., Temperature Compensation • Automatic ., Display • Backlit blue LCD with operation icon • digital display with 0.001 pH unit readability ,. Accessories • Extra Electrode • NIST Standard buffer solution (pH 4.0, 7.0, 10.01 x 500ml for each bottle) • standard electrode holder • Ac /DC Adaptor. .,. Power • 9V DC

1

-

-

... More
Vortex mixers Speed range 500-2000 rpm., Digital display for speed and time., Timer 1 min 99h59 min., with shaking heads for Microtubes(02ml and 0.5ml)(atleast 24 nos) and tubes of 2 ml(atleast 12 nos)15 ml and 50 ml(atleast 4 nos)., Operating manual

1

-

-

... More
Manual multi channel micro pipettes

1

-

-

... More
Manual single channel micro pipettes

1

-

-

... More
Electronic multi channel micro pipettes

1

-

-

... More
Electronic single channel micro pipettes

1

-

-

... More
Electronic weighting balance Weighing Capacity minimum load 0.5 Gm to maximum load 500gm., Readalability 0.1 mg., Fully Automatic Internal Calibratio ., Dye cast aluminium design for long term stability and accurate results suitable stabiliser for Electronic balance

1

-

-

... More
Autoclave (Vertical) ( Capacity 100 Litre) High pressure steam sterilizer with double /triple walled steam jacket and separate boiler., Chamber Capacity as per requirement(80 litre or more ≤ 100 litre)., operating temp. (121 to 138 c pressure) 1.1 to 2.2kg /cm2 of steam pressure. Spring loaded safety volume and automatic vaccum for jacket., Safety lock for closed pressure lock safety device.

1

-

-

... More
Hot air oven with temperature range 5°C above ambient to 250°C (Volume 125 Litre)

1

-

-

... More
Magnetic stirrer Specification : Max Speed: 1400 rpm or better Stirring Capacity -20Liters of water or better Dimensions (W x L x H) in mm- (270-280 x 170-175 x 90-95) Speed Accuracy: ±2 Heating Power: 750-800W Hot Plate Temperature: 20-300°C Hotplate Temperature Accuracy: ±5°C Temperature Hot Plate Diameter: 140-145mm Microcontroller based temperature control Option for temperature accuracy with external temperature sensor-±l°C Plate material should be chemical resistant with Silumin Ceramicized coating provision. An independent safety circuit with separate circuit switches off the heating if the normal hotplate temperature is exceeding by 25°C; Supply Voltage: 230V/50Hz Instrument should have CE certification Protection class- IP32

1

-

-

... More
BOD Incubator - Internal Size cms. : 55 X 85 X 55 (LxWxH) ., Shelves : 2 ., Temperature Range : + 5 degree C to 70 degree C., Controller Accuracy: +/-0.5 degree C of set value for Temp., Uniformity : +/-1 degree throughout chamber., Air Heater Element: Special Type S.S.Tubular Air Heaters with fins., Heat up Time: 30 min. up to 60 degree C without load., Cool Down time : 40 min. upto + 5 degree C without load., Cooler: Plate Fin Cooler., Compressor : EMMERSON Hermetically Sealed Brand., Controller: Digital Display Electronic Controller., Sensor : Pt-100., Internal Chamber: Stainless Steel 304 grade., External : Mild Steel Powder Coated., Inner Acrylic Door: Inner Full Size See through Acrylic 8 mm thick., Air Circulation: Motorized Blower from back and forced air circulation for temperature homogenicity., Safety Device: Adjustable hydraulic over-temperature limiter protector., PID Control: Microprocessor based PID Controller., Computer Interface: RS 485 / RS232 interface for multiple & single communication port., Cyclic Timer: 0 to 24 hrs X 7 days cyclic ON / OFF timer for illuminating port., Should have self supported transparent doors inside and magnetic gasket outer doors., Should have PUF Insulation., Should have door operated illumination lamp to work on 220/230 VAC., Should have Circular chart recorder for recording test conditions., Should be supplied with Stabilizer of sufficient capacity

1

-

-

... More
CO2 Incubator - Air jacketed CO2 incubator of inner volume 170-185 Lit cap (6-7cuft) made of Stain less steel interiors with 4 selves with individual glass doors., Microprocessor controlled and the display of CO2, temperature and other parameters., Temperature range from 500C above ambient to 5500C with 0.10 C accuracy., With tracking alarm, over temperature sensor. Independent thermostat for temperature safety., Auto decontamination with sterilization cycle sensors, with programmable tracking alarm., Should be supplied with two CO2 regulators and two cylinders. 8. Should be supplied with suitable stabilizer. 9. Power specifications 220 V 50Hz 10.

1

-

-

... More
Incubator Specification: - Inner chamber Stainless steel - Micro-computer control system with PID program - Over temperature protection - Auto-power break-off. - Double door seal - Temperature Range Ambient + 5 to 65 ºC - Temperature Resolution 0.1 - Temperature Uniformity + 0.5 - Working temperature 5 to 40ºC - Heating Power 500 W - Inner Chamber Dimension: Appox. (500x450x550)mm - Outer Dimension: Appox. 626x590x75mm - Digital timer 1-9999 min - Adjustable shelves - Load per rack 2 /15 kg per rack (minimum) - Power Supply 220V-230V /50HZ

1

-

-

... More
HPLC • Should be automated. • Bench top model. • User friendly operation. • Should be CE certified. • Should have RFID for reagent tracking identification. • Should have on board QC monitoring with Levey- Jennings and Statistical calculation. • Sampling from multiple sized primary tubes including. • Micro capillary collection tubes. • No sample preparation required. • Simple reagent and column replacement. • Automated maintenance. • Reagent identification and tracking. • Automatic barcode identification of samples. • Calibrators & controls IFCC traceable. • Unlimited Storage of calibration, QC. Data & chromatogram. • Less turn around time. * Should be able to do estimation for HbA1c and Thalasmia patients.

1

-

-

... More
RT- PCR with extractor Must have FerrotechPeltier based real time thermal cycling with bottom detection mode. Must have LED based excitation for trouble free long life calibration free operation. Must be able to accommodate any type of PCR tubes. Up to 48 test should be able to run simultaneously. Must have Sample preservation where in System shifts to 4 degree soon after thecompletion of assay. The manufacturer should offer compatible assays validated on the system. Automated Nucleic Acid Extraction System: Should have Processing Volumes 20-1000 µl, Sample Capacity 1-32, Retention of Magnetic Particles ≥98%, Uniformity of purification Cv3%, Heating temperature control range Lysing: Room temp.~120°C Elution: Room temp. ~120°C. Should be Mixing Multi-modes, multi-speed and adjustable, Disinfection method UV lamp. Kits species should be Kits with magnetic beads. Should be Computer integrated with tablet PC. Should have extraction kits both prefilled kits and manual (non prefilled) kits for all IVD applications. The instrument must be ISO 13485 certified and must offer a complete service and application support on the installation and post installation. A complete training on handling the instrument, programming interpretation has to be givenfree of cost by the bidder. Should have Online 2KVA UPS and standard Accessories. Brochure should be attached of the Equipment and demonstration for final consideration.

1

-

-

... More
Semi auto analyserIt should be micro processor controlled programmable Semi auto analyzer to perform routine biochemistry test (Including end point, fixed time & kinetic chemistry),enzyme immunoassays (with multistandard curve calibration memorization)etc. It should have facility to select more than 50 tests directly through test keys. It should offer a minimum of 175 user definable chemistry parameters. It should have a Peltier controlled reading block and below 20ul flow cell. Flow cell with peristaltic pump should be the part of the main unit. Analyzer should have additional facility to use both 6mm glass cuvettes and 10mm plastic cuvettes. It should have minimum 8 narrow band static interference fitters (not filter wheel) with wave length selectable from 340-670mm. It should display real time graph and plot at every one second each from start to finish of the test. It should have a large high resolution graphic backlit LCD alpha numeric display and built in full graphic printer for printing reaction curves and test result. It should have the facility to display the actual temp on screen especially for fixed time and kinetic test. The unit should have facility for quality control programme to use three level of controls and it should print the Levi-Jennings plot on daily and monthly basis. The software should be user friendly and guide the programmer step by step. The analyzer must have the provision for performing coagulation assays. It should have the provisions for multiform result output with comprehensive report of the patient. There should be provision for incubation of 6 to 10 test tubes/Cuvettes. UPS of required capacity with minimum half an hour back up should be supplied along with the equipment. Warranty 2 years after installation. Analyzer should have USB connectivity with PC & Printer. Bidders should supply all the necessary accessories to start and Run the equipment. Brochure should be attached of the Equipment and demonstration for final consideration.

1

-

-

... More
BACTERIOLOGICAL INCUBATOR Specification: - Inner chamber Stainless steel - Micro-computer control system with PID program - Over temperature protection - Auto-power break-off. - Double door seal - Temperature Range Ambient + 5 to 65 ºC - Temperature Resolution 0.1 - Temperature Uniformity + 0.5 - Working temperature 5 to 40ºC - Heating Power 500 W - Inner Chamber Dimension: Appox. (500x450x550)mm - Outer Dimension: Appox. 626x590x75mm - Digital timer 1-9999 min - Adjustable shelves - Load per rack 2 /15 kg per rack (minimum) - Power Supply 220V-230V /50HZ

1

-

-

... More
Micro pipettes (1µl - 10 µl)

1

-

-

... More
Micro pipettes (10µl - 100 µl)

1

-

-

... More
Micro pipettes (100µl - 1000 µl)

1

-

-

1

-

-

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.