Patliputra Medical College And Hospital Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 2,50,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_PMC_44514_3Bid Award Id
ViewTender No
221/pmcTender Authority
Patliputra Medical College And Hospital ViewPurchaser Address
-Website
http://http://www.pmchdhanbad.in/EN/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Blood Pressure Instrument (Non-Invasive) -Automatic BP monitor
Automatic BP monitor
Oscillometric measurement and Auscultatory measurement Measurement Range : Pressure:0 - 299mmHg, Pulse:40-200 beats / minute
Accuracy : Pressure:±3mmHg, Pulse:±5%
Power: AC 100V - 240V (Rechargeable Battery)
Memory: Last 99 measurements
1
-
-
... More
Height Measurement Scale
Floor Model Height Measuring Scale.
Measuring range : 20-205cm
1
-
-
... More
Weighing Machine
Capacity: 2-150 Kg (unit: Kg Lb St) Graduation: D = 100 g LCD display: 78 x 36 mm Vibration boot of automatic zero tracking, automatic power off Overload indication Low power indication Power: 2 x 3 v CR2032 lithium battery.
1
-
-
... More
Radio frequency ablation machine
Should have automatic and independent control of up to four electrodes at once.
Create up to two bipolar RF lesions at once.
Can be controlled using a wireless hand controller.
Should be fully operable using 12 inch touch screen.
Should displays individual RF readings for all four electrodes.
Thermal and Pulsed RF treatment on 1, 2, 3, or 4 electrodes.
Bipolar RF on 1 or 2 pairs of electrodes.
Independent electrode control with automatic stagger start feature.
Personal settings pre-sets for multiple physicians and procedures.
Facility for electronic procedure records and screen shots.
1
-
-
... More
FLUOROSCOPY MACHINE (C-ARM) IMAGE INTENSIFIFER: HIGH FREQUENCY C-ARM 9”.
Image Intensifying Tube 9 inches Normal = 9”, Zoom1 = 6”, Zoom2 = 4.5”.CCD Camera High resolution camera
Monitor One no.32”HD LED Monitor along with a trolley.
C-ARM MOBILE FRAME Rotation 180 degrees.
Motorized Up/Down 430 mm Horizontal Travel 200 mm
Arc Orbital Movement 120 degrees.
Wig Wag ±12.5 degrees. HIGH FREQUENCY X-RAY GENERATOR Tube Head and generator 40 KHz. stationary anode tube Max. Voltage 100 KV Fluoroscopic mA 0.1- 4.5mA (normal mode)
Mains Voltage 230V AC ± 10%, 50 Hz.Max. output power 3.5 KW (Stationary Tube)
PARAMETER SELECTIONS Display Fumigation friendly laminated LED water resistance display Technic Selection Fluoro Fluoroscopic Timer Five minutes cumulative timer with buzzer.
Fluoro mA Continuously variable. Temp. Sensor. Automatic cut off provided.
Power supply Single phase 230 V, ± 10% AC, 50 Hz Automatic Brightness Control Provided to operate the equipment in automatic mode for hands free operation.
Digital image memory systems: Digital HD Memory 100 frames and expendable on Pen Drive with:
1. Feature of LIVE and PULSE Fluoroscopy 2. Averaging of Frames 1 to 16 frame 3. Permanent storage up to 100 frame 4. Negative image 5. Image rotation 6. Pen drive for additional image storage.
1
-
-
... More
ULTRASOUND MACHINE
Ultrasound system should be suitable for use in point of care Ultrasound guided regional anaesthesia (PNB, neuraxial applications) & Ultrasound guided vascular access (PICC, PVC, arterial access)
It should have fully digital portable point of care ultrasound system with provision for Doppler examinations.
Ultrasound system should have one touch scanning 6 preset settings for Superficial Nerves {0-4cm}Medium Nerves {4-6cm}
Vascular Access Lung Scan Deep Nerves {+6cm} FAST Scan Ultrasound system should be light weight. Ultrasound system must have monitor dimension 13 - 17 inches flat panel with integrated touch screen display for finger gesture interface and pan in zoom feature. Minimum grey scale resolution to be 256 in 2D mode with upto 1024 scan lines, depending on transducer and imaging mode.
Ultrasound system should have transducer with detachable cable and provision of minimum 2 transducers.
System should be supplied with two Transducers (one each as below):
1) Linear transducer(L12-4) : 12 to 4 MHz for shallow applications, vessel imaging 2) Convex (C5-2 broadband curved array transducer ) : 5 to 2 MHz with 50mm radius of curvature for deeper applications Ultrasound system should be upgradable to ultrasound based Needle Tip Tracking technology for nerve blocks.
Ultrasound system should support imaging modes of M Mode, Colour Doppler, Colour Power Angio and 2D –Mode along with 2D -SonoCT real-time compound imaging , 2D-XRES Adaptive Image Processing, 2D-Tissue Harmonic Imaging technologies to drastically reduce speckle noise and noise artifacts. Ultrasound system should have technology to provide 3 angle settings to comply to the needle trajectory angle for optimized visualization of needle. Ultrasound system should have atleast 75 to 80 frames per second in high frame rate mode. Ultrasound system should have imaging provision of Auto scan, zoom magnification, Cineloop review. The system must have HDMI, speakers, 5 USB ports, Ethernet, WIFI connection, DICOM, MWL remote services . The system must be equipped with full suite of connectivity features to support built in WIFI for DICOM data transfer to hospital and cloud PACS, to easily share and store images.
Unit should function with System on AC power: 100-240 V~, 50 Hz or 60 Hz, and can be used for scanning for up to 3 hours on a new, fully charged replaceable lithium battery. Ultrasound system should be USFDA Certified .
Warranty: The unit, transducers and all accessories should be covered with warranty for five (5) years.
1
-
-
... More
Patients controlled analgesia system (Portable)
Flow rate range 0.01 - 999.9ml/h
o 0.01-99.99ml/hinincrementsof0.01ml/h
o 100.0-999.9ml/hinincrementsof0.1ml/h
Syringe sizes :- 2/3; 5; 10; 20; 30; 50/50ml
Online rate modification without deliveryinterruption
Accuracyofsetdeliveryrateequalorlessthantyp.+/-2 %
Bolusapplication Delivery rate 1 – 1,800 ml/h; max. Bolus Volume 99.99ml
Bolus ondemand Bolus with volume/dosepre-selection
Bolus over time (1 min - 24h) cclusion Pressure: 75 mmhg to 900 mmhg
KVOrate Rate = 10 ml/h: KVO rate 3ml/h
Rate 10 ml/h: KVO rate 1ml/h Rate 1 ml/h: KVO rate = setrate
User individual configuration or deactivation of KVO rates possible.
Drug library :- 750 drugs including all parameters in drug library Up to 10 user defined drug categories
Medication error prevention through dose limits referring to selecteddrug
Automated syringe change for optimal start upcharacteristics
Standardized User Interface for all Syringe & volumetricinfusion pumps. Optional upgrade of pumps to special therapy like TCI, PCA of thesame Integrated docking system with central alarm and runningindication
Dose calculation- Automatic calculation of the delivery rate based on dose entries in mg, µg, IE or mmol, weight- and/or time related (e.g. mg per kg/min; mg/kg/h; mg/kg/24h, bolus application in mg, µg, IE, mmol per kg and/or per time unit (min) with automatic calculation of the bolus rate for one bolus infusion.Key pad: - Clearly structured, back lit key pad with not more than 8 keys for fast and intuitive operation; identical to Infusion pump SafetyFeatures:- Free flow-protection: - Integrated piston brake within syringe drive to prevent free flow dring Syringe change.Occlusionalarmpressurelimits:-Adjustablein9steps(0.1-1.2barorDisplayinmmHg) Datalock:- Adjustablein2safetylevels(parametersanddisposables) Automatic bolus reduction after occlusion alarm Power Supply:- Main Powersupply:- Mains adaptor (rated voltage 100…240 V AC, 50/60 Hz) for standalone operation.
Externallowvoltage 11 … 15 V; via external power supply 12 V or via central power Station Batterytype:- Rechargeable NiMH battery pack, quick and easy exchange without using screw-driver to open thepump. Battery operating time approx. 14 h at 20 ml/h with Battery capacity display in h and min. PCA Pump should be USFDA & CE Certified.
1
-
-
... More
Intrathecal infusion pumps
Pump and catheter part of an implantable, programmable drug infusion system that store and deliver medication into the intrathecal space. Combined with the Control, to eliminate systemic opioids and provide effective pain relief.
Smart software to guide the clinician through programming the system, via information and warning screens
Full-body MRI compatibility at 1.5 and 3-Tesla under specific conditions.
Critical therapy and patient data stored in the pump for follow-up at other institutions.
Flex dosing schedules should allow drug delivery to be matched to patient needs, providing chronic pain relief throughout the day
Should have a separate touchscreen interface compatible with the pump. Should have simple steps for refill and implant. Built-in auto-calculations for volume and rates. Software for patients who can alleviate their unpredictable pain without the use of systemic opioids.
One can set a therapeutic daily dose and allow patients on-demand bolusing within limits.
Feature of clear and informative bolus confirmations, lockout details, and alerts.
Should be easy and simple to use.
1
-
-
... More
OT Table (fluoroscopy compatible)
Four Section eccentrically positioned radio-translucent table top without cross members to facilitate C-arm imaging. The table top made of radio-translucent material for excellent fluoroscopic capability.
Operating positions i.e. Height adjustment, Trendelenburg, Reverse Trendelenburg, Lateral Tilt and Back Section precisely controlled by handheld Remote.The powered movements actuated by Electro-hydraulic System comprising of hydraulic motor pump with low noise level of less than 50dBA and solenoid valves to assure smooth and quiet movements.
The Head and Leg Section removable and interchangeable, capacitating a single table’s use in varied surgical procedures. These are manually operated by means of ratchet system.Built-in Kidney Elevator – manually gear operated.
Non-corrosive SS304 Grade Stainless Steel base and cylinder covers, side-rails, clamps and standard accessories.
Table top size (L x W) : 1900 x 500 mm Height : 750 mm - 1000 mm
Trendelenburg / Reverse Trendelenburg : min ± 20° Lateral Tilt (Left/Right) : min. ±15°Back section adjustment : + 80° – 20° down
Leg section adjustment : + 15° – 90° Head section adjustment : +45° – 90° down, Variation ±10%
Load capacity : 180 KgsPower supply : 220V AC – 50HzWith Orthopaedic attachments.
1
-
-
... More
Nerve Locator
Nerve Stimulator for Nerve blocks under Regional Anesthesia or Nerve Locator for Regional Blocks.
Portable Battery operated small sized unit. Should have combined Mapper and Locator functions related to Nerve Blocks during Regional anesthesia. Battery: Should run on any 9V (alkaline) batteries.Stimulation current: 5 mA max (0-12 k), Stimulation Voltage: 95V Stimulation frequency: 1 Hz / 2 Hz, Allowable load impedance: 0 k – 12
Stimulus duration : 1.0 ms - 0.5 ms - 0.3 ms - 0.1 ms - 0.05 ms Digital dial for Precise and tactile current adjustment with convenient tactile feedback. Sense function stimulation duration- SENSe (0.10 ms - 0.10 ms - 0.15 ms to 1.0 ms)
Current measuring accuracy: +/- 0.02 MaImpedance measuring range: 1 KOhms - 90 KOhms for target stimulation current 0.5 mA The enlarged full graphics LC display having good visibility with wide angle of view. The following information should be displayed on the stimulation screen at all times: Stimulus amplitude in mA (large digits)Current range: Stimulus duration in ms Stimulus frequency in Hz Load impedance in kΩ Direct access keys: Direct access keys to let conveniently adapt the most important and frequently used settings to the clinical environment. (Amplitude range - mA, stimulus duration - ms, stimulus frequency - Hz). Sequential electrical nerve stimulation (SENSe) - Featuring the option of selecting a frequency of either 1 Hz, 2 Hz or 3 Hz for SENSe and a stimulus duration of 0.05 ms - 0.10 ms - 0.30 ms -0.50 ms - 1.00 ms. It should have following Safety Features: Threshold current - To visually and acoustically indicate when the stimulus duration-dependent current threshold goes out-of-tolerance indicating that the needle may be too close to the nerve. Visual warning: The full digits of the target current display converted to contoured digits when the current threshold drops below the preset level. The LED flashing yellow (instead of green).
Acoustic warning: A warning signal should be additionally sounded. Auto Adjust current feature - the current adjusting automatically when the stimulus duration is changed. Accessories: Pen: The Pen for percutaneous nerve mapping to help to pre-assess the puncture site. Also suitable for training sessions.
1
-
-
... More
Computer
Windows 10 Home 64
8th Generation Intel® Core™ i5 processor
8 GB DDR4-SDRAM
2 TB 7200 rpm SATA
NVIDIA® GeForce
1
-
-
... More
Anodyne Machine (for diabetic foot care)
Designed to provide foot and leg pain relief by increasing foot and calf circulation. The pain relief technology should deliver two 30-minute treatments in between a 20-minute cooling cycle and has an auto shut-off feature that activate after each 80-minute session. Should have comfortable foot and calf therapy pads to increase circulation over a total therapeutic surface area.
1
-
-
... More
Transcutaneous Electric Nerve Stimulating Machine
Should be Non Invasive Radio Frequency Pain Management using Neuro Modulation
Portable Battery operated small sized unit
Should be Useful for treatment of: Chronic Pain Relief, Neuropathic Pain & Symptoms, Diabetic Neuropathies, Bell’s Palsy, Trigeminal Neuralgia, Tennis Elbow, Golfer’s Elbow & Regional Pain Syndromes.
Square wave output with a Superimposed RF Waveform
Graphical Display with backlight
Output Current range of 0-30 mA
Transcutaneous Nerve Mapping with Nerve Mapper Probe
On Board timer to keep track of Therapy Time
User adjustable Pulse Width 0.1 ms and 0.2 ms
User adjustable Frequency of 1,2,5,10 Hz
Must have ISO 13485 and CE mark
1
-
-
... More
Anaesthesia Machine with resuscitation equipments and accessories
Anaesthesia Delivery Machines (Boyle’s Apparatus).
Should be Suitable for Trauma, Minor Operating Rooms.
Adult and Paediatric applications.Facility and Connections for 2 Gases: Oxygen and Nitrous Oxide.
The machines should have the facility for Low Flow Anaesthesia procedure with the placement of 4 Tube Rotameters / Flowmeters. Anti-Hypoxia Guard that ensures a minimum of 25% Oxygen supply.
Nitrous Oxide Cut Off System. OFWD alarm system in case of Oxygen Failure.
Low Battery Alarm. High / Low Pressure Alarm Connection of a Selectatec Bracket back bar to mount Tec. Vaporisers
Should be supplied with Vaporiser. Connection of Pin Index Cylinders and Pipeline Connections for supply of gases.
MS Metal Frame + FRP Fibre Body.Resuscitation equipments and accessories Ambu bag and mask.
1
-
-
... More
Crash Cart
With Polystrene boxes and drawers with medicine container of different sizes Structure made of 25mm square pipe thickness 1.6mm. Two salves made of 1mm ss sheet with rail (three sides). ABS six drawers raised at the middle with centre locking. Six small container raised inside the upper drwers for keeping the sutures. One spot led light fitted at the centre of the trolley. Sliding salve fitted at the left side of the trolley with push handle.
Diffib perforated tray fitted at the top (detouchable). IV pole, cylinder carrier provission. Wall guard fitted at the bottom.(wholly ss) Six colored bins fitted under the diffib tray (detouchable). Finish with glossy polish. Mounted on 100mm caster two with break.
Over all size: 750mm(l)x400mm(w)x1500mm(h)
1
-
-
... More
Monitors with vital signs (NIBP, PR, ECG, SpO2, Temperature, RR)
Suitable for Adult, paediatric & neonatal patient monitoring. Monitor NIBP, PR, ECG, SpO2, Dual Temperature, RR as standard parameters. 3/5 Lead ECG Inbuilt rechargeable battery backup at least 2 hrs. Nellcore / MASIMO SpO2 technology. Should have capability for Invasive monitoring.
ST analysis, Arrhythmia detection. 12’’ TFT-LCD colour touch screen display with min. 2 to 7 channels of waveforms simultaneously.. Defibrillator and ESU protection. Able to display at least 120 hrs of trend and 60 events with waveform, Nurse call, VGA output port, USB port, inbuilt three channel recorder as standard. European CE/US FDA certificate.
1
-
-
... More
Nerve Stimulator 5Ch fully digital with digital treatment timer along with Soft Key Touch for Treatment mode Selector & auto mode Selector.To relieve Pain effectively in Arthiris, Neuralgia, Migraine, Spinal Disc, Surgical Trauma, Headache, Sciatica etc.
Treatment Mode: : 7 Mode (Normal, Burst, Accup., Conventional, Sweep, Pwm, Diadynamic)
Program: 12 Programs (6 Program in Monophasic and 6 Program in Biphasic)
Frequency Range: 1 to 200Hz(Normal Mode) Sweep Frequency: 1-100Hz, continuously Adjustable
Treatment Time : 60 minutes Display: LCD Display
Intensity: 0-60mA Current Type: Monophasic and Biphasic
Output: Dual Channel Output Voltage Waveform: Square and Rectangular continuously variable Pulse
Power Supply: 12 VDC AdapterBattery; 9V Rechargeable battery
1
-
-
... More
Multimedia Projector with screen
• Brightness: 3600 lm
• Projector Type: XGA | Chipset: LCD
• Maximum Projection Distance: 10.4 ft
• Lamp Life: 5000 hr
• Resolution: 1024 X 768 pixel
• Aspect Ratio: 4:3
• Wireless Network Connectivity
Pull down Screen 84Inch- Diagonal Approx. 4 feet (height) x 6 feet (width) In 4:03 Aspect Ratio.
1
-
-
... More
AMC %
1
-
-
... More
CMC %
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements