Patliputra Medical College And Hospital Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Patliputra Medical College And Hospital Tender

Goods
Healthcare and Medicine
Eprocure
Opening Date16 Nov 2020
Closing Date2 Dec 2020
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
OCT Specification :- Scanning device: Spectral Domain, Fundus Imaging: Live Fundus image, Small Foot print, Scanning rate: 27000-65000 A scans / second or faster, Axial resolution: Min 5 Microns, Minimum Pupil Diameter: 1= 2 mm, Precious in Fovea Finder, Macula and Glaucoma specific scanning protocols, with Normative database for RNFL, ILMRPE , ILM , RPE layer maps, Patient to Observer position 90 degrees., Complete control using mouse - No Joystick, Auto Patient Recall - System should be able to recall patient position during subsequent visits, Auto Centering ONH : System should automatically detect the ONFI center for RNFL analysis, Auto repeat mode using vascular registration, Cube Scanning protocol with 3D rendering, Guided progression analysis, Anterior Segment Imaging Capacity, Easy connectivity with Visual Field Analyzer and fundus camera to combine report. After sales service should be available directly from manufacturer with availability of spare parts in the region. Certification- European CE/FDA(US)

1

-

-

... More
Digital Slit Lamp with Display System Specification : 1. MAGNIFICATION - 5X, 8x, 12x, 20x,.32x with 10x eyepieces 2. FIELD OF VIEW - 40mm To 6mm With 10x Eyepiece 3. EYEPIECE MAGNIFICATION - 10x High-Eyepoint Eyepieces, +-8D compensation of ametropia optional 12.5x high eye-point pieces, +- 8D compensation of ametropia. 4. PUPILLARY ADJUSTMENT - 55mm - 75mm. 5.WIDTH OF SLIT IMAGE - 0 To 14mm, Continuously Adjustable 6. LENGTH OF SLIT IMAGE - in steps: 0.3/ 3.5/ 8 / 14mm; continuous 1 to 6mm 7.ROTATION OF SLIT IMAGE - +-90°, continuous. 8. DECENTRATION OF SLIT IMAGE - +-4° horizontal, click stop at 0°. 9. SWIVEL RANGE OF SLIT PROJECTOR. 180°, SCAL FOR ANGULAR DIFFERENCE, CLICK STOP AT 0°. 10. ANGEL OF INCIDENCE - 0°; 0° to 20°, titable with tiltable prism head 11. FILTERS - blue, green(red-free), gray(neutral) swing-intype; UV protection filter, and screen for diffuse illumination. 12. FREE WORKING DISTANCE - 66mm Exit Prism/Patient's Eye. 13.TRAVEL OF INSTRUMENT BASE - Vertical: 30mm Vertical: 110mm Lateral & 90mm Axial. 14. VERTICAL TRAVEL OF CHIN REST - 80mm 15.PROJECTION ILLUMINATION– 6V/20W Halogen lamp. 16. BRIGHTNESS - Continous adjustable. 17. VOLTAGE - 100 TO 240 V. 18. WEIGHT - Basic instrument 9.75kg(21.49Ibs). 19. SLIT LAMP IMAGING MODULE– (SENSOR TYPE) : 1/2, 5"CMOS, Rolling Shutter HD Camera (SENSOR SIZE) : 2592 X 1944 pixel.(FRAME RATE) : approx. 25fbs at 648 x 486 pixel, approx.15 fbs at1296 x 972 pixel, approx, 5 fbs at 2592 x 1944 pixel. (INTERFACE) : USB 2.0, 400 Mb/s (SIGNAL TO NOISE RATIO) : 38dB. (DYNAMIC RANGE) : 70 Db. (RECORDING AND DOCUMENTATION) : external computer system for documentation 20. ACCESSORIES : digital imaging and image processing instrument table Certification- European CE/FDA(US)

1

-

-

... More
Specular Microscope with Pachymeter for (Cadaver Cornea ). Specification : • Type- Non-contact objective Lens. • Field of view- 450μmx500μm • CCD Camera- Monochrome • Illumination- Halogen Lamp, 6V 20W • Power- 110/220V - 60/50 Hz • Weight- 10 lb (4.55 kg) • Dimensions- 7.25"X 9" X17.75" Certification- European CE/FDA(US)

1

-

-

... More
Lensometer Specification : (a)Full graphic LCD with 5.7-inch touch color panel (b )User-friendly tiltable LCD (c) Green light/UV transmittance measurement (c) Distortion check (d) Power supply- AC 100 to 240 V, 50/60Hz (e) Power consumption - 60VA (f) Dimension - 220(W) X 252(D) X 430 (H)mm (g) Mass - 5.0 kg Certification- European CE/FDA(US)

1

-

-

... More
Fundus Camera Specification : Field angles: 45° , 35° and 30° small pupil, Image mask: 45°, 35°, black, dark, transparent, bright, Display: 19" TFT Monitor (1280 x 1024 pixels), Capture modes : Colour, green, blue, red, fluorescein angiography/FA in red Both IR observation, Anterior Segment images, Fundus Auto fluorescence , CG angiography(Upgraded), Stereo, MPD, Blue and red filters for documentation of the nerve fiber layer and choroids., Compensation of Ametropia: +35... -35D continuous, Pupil diameter: 4.0mm, 3.3 mm ( 30 degree small pupil),Working Distance: Front lens to patient's eye 40 mm /1.6 inches, Interfaces: USB Port and network connectors, DVI port, Export: Image format DICOM, Bitmap, JPEG Patient list, Capture technology: Separate sensors for black and white and colour modes, Upgradeability: Upgradeability of software should be possible, Instrument table: Asymmetrical, Fixation Targets: External and Internal Attention mode for internal fixation target (magnified and blinking cross)Various programmed sequences or freely positionable, Quantitative information: Extended PDT data including the percentage display of classic, CNV and body surface area, Determining the C/D ratio for glaucoma management, Correction of the absolute data measured using the patient's refraction data, Qualitative Information : Geocorrected overlay of images for rapid glaucoma diagnosis Image processing with shortcuts. Mapping for Montage, Overlay, Dynamic Comparison ,Text into Graphics, Patient Information : Recording of refraction values, weight and size, Search for field angles, right/left eye and stereo image, Varied personalized print layouts with automatic image arrangement. Certification - European CE/FDA(US)

1

-

-

... More
Visual Field Analyser Specification : High quality Goldman standard automated perimeter with bowl size 30cm, Maximum intensity I0,000Asb, Bowl illumination 31.5Asb, USB storage device, Internal hard disk drive with Magneto Optical Disk (MOD) drive., Stimulation duration 200ms,wavelength Broad band visible light, Stimulus/Background colour White on White, Blue on yellow (SWAP), Maximum temporal range 90Deg.Suitable for central 30 as well as full field testing , Central field test patterns 30-2,24-2,10-2,Macula, Peripheral field test pattern 60-4,Nasal Step, Threshold test strategies full threshold, Fast Pac, SITA or equivalent, Glaucoma Progression Analysis software (GPA), Structure (RNFL) and Function loss common print out when attached with OCT., Screening field test P-60,FF-80,FF-120,FF-240,Nasal Step for periphery . Screening test strategies Two zone, Three Zone and Quantify Defects., Kinetic Testing, Custom Test, Stimulus Size I-V as per Goldman standards, Glaucoma hemifield test. Heijl - Krakau blind spot monitor, Video eye monitoring, Trial Lens Holder, Gaze tracking System, Motorisedchinrest, Original Motorised table, Laser Jet Printer. Certification - European CE/FDA(US)

1

-

-

... More
Perkin’s Tonometer

1

-

-

... More
Iris Forcep Titanium

1

-

-

... More
Placido Disc

1

-

-

... More
Steriliser Boiler

1

-

-

... More
Tray Squire(SS)

1

-

-

... More
Formalin Chamber Big

1

-

-

... More
Kidney Tray SS

1

-

-

... More
Lifter

1

-

-

... More
Surgical Eye Draps Disposable

1

-

-

... More
Surgical Gown Disposable

1

-

-

... More
Surgical Mask Disposable

1

-

-

... More
Halogen Bulb for Microscope 12V 100W

1

-

-

... More
Halogen Bulb for Microscope 15V 150W

1

-

-

... More
Surgical Towel for Instruments Trolley Disposable

1

-

-

... More
Crescent Knife (Diamond)

1

-

-

... More
Keratome (Diamond)

1

-

-

... More
Trial Box (Dark Room Test)

1

-

-

... More
Semi Operating Chair

1

-

-

... More
Electrolysis Machine

1

-

-

... More
Florescine Strip

1

-

-

... More
Schirmer's Strip

1

-

-

1

-

-

1

-

-

-

-

-

-

-

-

-

-

-

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.