National Rural Employment Programme Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 1,14,900Document Cost
₹ 10,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NREPR_85865_1Bid Award Id
ViewTender No
NREP1/47_I/23-24Tender Authority
National Rural Employment Programme ViewPurchaser Address
-Website
http://jharkhandtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Providing designation 75B one brick flat soling joints fitted with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I
384.53
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up ot plinth level: 1:3:6 (1 Cement:3 coarse sand (Zone-III):6 graded stone aggregate 20 mm nominal size)
13.07
-
-
1:2:4 (1 Cement: 2 Coarse sand (Zone-III): 6 graded stone aggreagthe 20 mm nominla Size)
25.39
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering finishing and reinforcement- All work up to plinth level: 1:1.5:3 (1 Cement: 1.5 coarse sand (Zone-III): 3 Graded stone aggregate 20 mm nominal size) Foundation
43.4
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttesses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc above plinth level up to floor five level, exchuding cost of centering, shuttering finishing and reinforcement: Column
4.96
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 landings, balconies, shelves, chajjas, lintels, bands, plan window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone0III) :3 graded stone aggregate 20mm nominal size). Lintel
0.91
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 landings, balconies, shelves, chajjas, lintels, bands, plan window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone0III) :3 graded stone aggregate 20mm nominal size). Chajja
0.49
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 landings, balconies, shelves, chajjas, lintels, bands, plan window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone0III) :3 graded stone aggregate 20mm nominal size). Beam
18.53
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 landings, balconies, shelves, chajjas, lintels, bands, plan window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone0III) :3 graded stone aggregate 20mm nominal size). Slab
34.72
-
-
Providing Toe steel reinforcement of 8mm dia rods as approved
4.65
-
-
Providing Toe steel reinforcement of 10mm dia rods as approved
3.1
-
-
Providing Toe steel reinforcement of 12& 32 mm dia rods as approved
7.75
-
-
Centering and shuttering including strutting propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete
66.2
-
-
Columns, Pillars, Piers, Abutments, Posts and Struts
82.5
-
-
Lintels, beams, plinth beams, girders, bressamers and cantilevers
296.52
-
-
Suspended floors, roofs, landing, balconies and access platform
291.78
-
-
Weather shade, Chajjas, corbels etc. including edges
8.1
-
-
Providing designation 75B brick work in C.M. (1:6) in foundation and plinth approved quality of clean coarse sand of F.M. 2 to 25 including roviding 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an
8.89
-
-
Providing 25mm thick Damp Proof Course with cement concrete M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips of 20mm to 6mm size graded and clean course sand of F.M. 25 to 3 including screening, shuttering and mixing cement concrete in mixer with 5% cicio or any other approved water proffing compound and placing in position, striking, curing, taxes and royalty all complete as per building specification and direction of E/I
39
-
-
Providing designation 75B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I
57.29
-
-
Providing designation 125mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approvid quality of clean coarse snd of F.M. 2 to 25 including the cost of screeining carriage of materials, scaffolding raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I
0.68
-
-
Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water. Scaffolding taxes and royalty all complate as per building specification and direction of E/I
277.75
-
-
Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I
271.88
-
-
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E.I
412.08
-
-
Providing and applying white cement based putty of everage thickaness 1 mm, of approved brand and manufacturer, over the plasterd wall surface to prepare the surface even and smooth complate.
689.83
-
-
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smoth with pumice stone or fine sand paper, applying putty wherever required scaffolding washing of floor and taxes all complete as per building and specification of E/I
689.83
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @1.67 ltr/10 sqm over and including priming coat of exterion primer applied @2.20 kg/10sqm)
271.88
-
-
Providing and layng Double charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less then 0.08% and conforming to IS: 15622/ISO 13006 of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand0, jointing with grey cement shurry @3.3 kg/sqm including grouting the inints with wite cement and matching pigments etc, complete Size of tiles 600x600mm.
271.23
-
-
Provding and laying flamaed finish Granite stone flooring in requied design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 Cement : 4 coarse sand) laid and jointed with cement shurry and pointing with white cement slurry admixed with plgment of matching shade including rubing curing and polishing etc. all complete as specified and as directed by the Engineer in Charge:
24.1
-
-
Exta for pre finished nosing to treads of steps of marble stone.
50.5
-
-
Suppliying fitting and fixing MS. Grill made of 20X6mm MS. Flat/ square as per approved dostgn and drawing properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/L (where materials is not supplied by the deptt.)
288
-
-
Providing two coats of synthetic enamel paint of approved shade and make over steel surface indluding deaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I
14.4
-
-
Providing and fixing factory made uPVC white clour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60+_ 0.2 mm thick galvanized mild steel section made from rool forming process of required length (shape & size according to uPVC profile). appropriate dimension of uPVC extrnded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon roollers (weight bearing capacity to be 40 kg). GI fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as perapproved drawing & direction of Engineer-in-Charge.(single/double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in Not: for uPVC frame and sash extruded profiles mimus 5% tolerance in dimension i.e.in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof S.S wire mesh (Two mos. Glazed & one no. wire mesh panels) made of (big series) frame 116x45 mm & sash 46x62 mm both having wall thickness of 2.3 +_ 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
14.4
-
-
Providing and fixing glazing in aluminlum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
11.52
-
-
Providing anf fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including, welding grinding, buffing polishing and making curvature (sherever required) and fitting the same with necessary stainless steel nuts and bolt complete. i/c fixing the railing with necessary accessories & stainless steel dash fasteners. stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
15.12
-
-
Providing and fixing pressed steel door frames cdonforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 25mm thick eith morter guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of of the surface as directed by Engineer-in-charge:
43.2
-
-
Supplying, fitting & fixing 35mm thick solid core type non-decorative double leaf flush shutter in doors and windows with block board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneeres of standard makew with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E.L
20.16
-
-
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse sidde of adhesive bonding quality conforming to Is: 2046 Type S, including cost of adhesive of approved quality.
48.38
-
-
Providing and fixing on wall face unplasticised Rigid PVC. Rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes, 110 mm diameter
15
-
-
Providing and fixing on wall face unplasticised -PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion. Bend 87.50 110 mm bend
8
-
-
shoe (Plain) 110 mm Shoe
8
-
-
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S, screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
15
-
-
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3 with punning over exposed surface all complete as per building specification and direction of E/L
72.5
-
-
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (Zone-III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size) well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
43.5
-
-
Water proofing for Old and New Roof Slab:- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed ready to use acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specitications with following step :- (a) Surface preparation :- Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint/ coating, and cement laltance by cleaning with compressed air & water jel including all materials. labour, tools complete. Ponding test to be done with non shrink expanding admixture of Sika India Pvt. Ltd. 'MYK Schomberg / Dr Fixit/Fosroc or equivalent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shallbe chamfered with 150mm X'150 mm fillet of mortar (Cement: sand- 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged (b) 1st Coat:- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parpet wall upto 600 mm by brush or roller. After 1st coat of application 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @ 1.50 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured" (c) 2nd Coat:- To apply the 2nd coat of two component acrylic modified, ready to-use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat of two component acrylic modified, ready to-use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat of two component acrylic modified, ready to-use, flexible cementitious material right angle to the 1st soat over the glass fibre laid surface. 2nd coat should be applied @ 0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to indentify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Waterproofing Brad: Sike Topsel 109hi / Fosroc Brushbond RFX/Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance - Chemical Base Part A Acrylic (d) Protection of treated surface with PCC:- The treated surface should be coverd with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards tlre rain outlets in alternate panels of 2 mlx2ml keeping 6mm gap between the panel joint, Integral water proofing admixture conforming to IS 2645 @ of 100ml per bag of cement to be added in the screed concrete (paid separately for this Items).- All corners shall be chamfered vrith 150mmX150mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the eripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sike India Pvt. Ld / MYK Schombery / Dr Fixit/ Fosroc. For the purpose of measurement the entire treated surface will be measured." (e) Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand- Sika India Pvt. Ltd / MYK Schomberg / Dr Fixit/Fosroc. warrenty for five years.
277.75
-
-
Covering of treated surface writh PCC:- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) maintaining slope in alternate 2 mt x 2mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of FM 25 in 3 including screeinig, shuttering and mixing cement coacrete in mixer with admixture of integral water proofing and placing in position striking curing taxes and royality all complete as per building specification and direction of E/L Panels that has been left should be casted next day- There should be 6 mm gap between panels. Brand- Sika_Plastocrate plus MYK proof WP 10, Fosroc- Conplast X421 ic. Dr fixit Pidiproof LW-
277.75
-
-
Providing and filling of 6mm thick Groove betwwn 25mm PCC Pancls with Polysulphide Sealant (Poring Grade) as per drawings and technical specifications and direction of Engg in Charge (with 18% GST). Brand:- Sike Polysulphide Fosror- Thinflex 600Dr. Fixit Pidseal PS(42P),MYK Seal PS of Euivalent.
277.75
-
-
Carriage of material
Brick-
44.11
-
-
Sand-
149.47
-
-
Chips-
115.55
-
-
Metal-
12.54
-
-
Cement-
66.43
-
-
Steel-
15.49
-
-
Point wiring in PVC conduit, with modular type switch - Wiring for light poit/exhaust fan point/call point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/GI. box etc. as required Group A
24
-
-
Power plug wiring in PVC conduit (2x4 sq.mm) - Wiring for light/power plug with 2 x 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as reqired.
50
-
-
Circuit/submin wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes PVC insulated copper conductor. Single core cable in surface/recessed PVC cconduit as required.
2 x1.5 sq.mm. + 1x1.5 sq.mm.earth wire
40
-
-
2 x2.5 sq.mm. + 1x2.5 sq.mm.earth wire
30
-
-
2 x10.0 sq.mm. + 1x10.0 sq.mm.earth wire
30
-
-
4 x6.0 sq.mm. + 2x6.0 sq.mm.earth wire
20
-
-
Wiring in existing conduit - Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. 2 x4 sq.mm.
20
-
-
TV cable in existing conduit - Supplying and drawing co-axial TV cable RG-6 grade copper coductor, PE insulated, with PVC sheath in the existing surface/PVC conduit as required.
20
-
-
S/F PVC conduit - supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required. 20mm
20
-
-
S/F PVC /G.I boxes - Supplying and fixing PVC/G.I box of following sizes on surface or inrecess with suitable size of phenolic laminated sheet cover infront including painting etc. as required.
75mm x75mm x50mm dep/(4"4")
4
-
-
S/F Modular type Switch / Socket: Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc as required.
5/6 amps, one way switch
4
-
-
15/16 amps, one way switch
4
-
-
3 pin 5/6 amps, socket outlet
4
-
-
S/F Modular type electrionic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
24
-
-
Supplying anf dixing Modular type blanking plate-supplying and fixing modular blanking plate on existing modular plate switch box excluding modular plate etc. as required.
2
-
-
Supply & fixing 20A SON MCB Industrial Socket Outlet: Supply and fixing of 20A, 240V, SPN insustrial type socket outlet with 2 poles and earth, metal enclosed plug top along with 20 amps 'C' series, SP MCCB, in sheet steel enclosure, on surface or in recess with chained metal cover for socket out let and complete with connections, testing and commissioning etc as required. Make L&T/ABB.Legrand/Polycab/Philips
1
-
-
Providing & fixing : Porviding and fixing of MV danger notice plate of 200mmx150 mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.
1
-
-
S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front indluding providing and fixing 5 pin, 5/6 amps socket outlet and 5/6 amps plano tyep switch connection, painting etc. as required.
4
-
-
S/F power plug point with modular type accessories - Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 6 pin, 15/16 amps socket outlet and 15/16 amps plano type switch connection, painting etc. as requird.
4
-
-
S/F ceiling rose - Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as require.
48
-
-
S/F batten holder - Supplying and fixing batten/angle holder including connection etc. as required.
4
-
-
ITC fluorescent fitting directly on surface - Installtion, testing and commissioning of Pre-wired, fluorescent fitting/compact fluorescent fitting of all type, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq.mm. FR PVC insulated, copper conduit.
24
-
-
ITC Fluorescent fitting with down rods - Installation, testing and commissioning of Pr-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. including supplying and fixing ball and socket arrangement, 2 no. down rods of 20mm dia stee.
24
-
-
ITC ceiling fan - Installation, testing and commissioning of ceiling fan, including wiring the own rods of standard length (up to 30 cm) with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable etc. as required
24
-
-
S/F MCCB in cubical panel board: Supply and fixing following rating & capacity 4pole MCCB in existing cubicle panel board. Including drilling holes in panel, making connections etc as required. 25 to 100A, fixed thermal rating (to be used as incomer for light & UPS SDB as floor, wall mounted panel)
1
-
-
125A, 16KA fixed thermal rating( to be used as incomer for tap of bay of rising mains)
1
-
-
160A, 35kA fixed thermal rating( to be used as incomer for SDB as floor wall mounted panel)
1
-
-
200A, 35kA-(5 nos) fixed thermal setting with spreader links ( to be used as incomer for tap off box of rising mains & 1 no for UPS room SDB)
1
-
-
S/F S.P. MCB DB - Supplying and fixing following way single pole netural, sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, netural husbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB.RCCB.Isolator) 8 way, duble door
1
-
-
S/F T.P MCB DB - Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB without MCB/RCCB/Isolator) 4 way (4 + 12), Double door, Horizontal type
1
-
-
6 way (4 + 12), Double door, Horizontal type
1
-
-
S/F 'C' series, MCB - Supplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of foolowing poles in the existing MCB DB complete with connection, testing and commossioning etc. as required.
6\32 amps, Single Pole
2
-
-
40 amps, TPN
2
-
-
40 amps. DP
2
-
-
50/63 a,ps, DP
2
-
-
S/F four pole MCB isolator - Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and dommissioining etc. as required
40 amps
2
-
-
80/100 amps
2
-
-
Copper earth plate elecrtode - Earthing with copper earth plate 600mmx 600mm x 3mm thick indluding accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (but with charcoal or coke and salt)
1
-
-
S/L 8 SWG copper wire in ground - Supplying and laying 8 SWG copper wire at 0.50 meter below ground level for conductor earth, including soldering etc. as required
1
-
-
P/F G.I. lightning conductor final - Providing and fixing of GI lightning conductor final, made of 25mm dia 300mm long, copper tube, having single prong at top, with 85mm dia 3mm thick copper base plate base including holes etc. complete as required.
1
-
-
P/F GI lightining conductor tape in horizontal run - Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightningconductor complete as requied. (For horizontal run)
20
-
-
P/F G.I. lightning conductor tape in vertical run - Provding and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
40
-
-
MV cable laying upto 120 sq.mm. in ground without sand and cover - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 185 sq.mm. but not exceeding 400 sq.mm direct in ground including excavation, and refilling the trench etc. as required, but excluding sand cushioning and protective covering.
20
-
-
MV Cable :- Supply of ISI marked aluminium cable conductor XLPE PVC Insulated Cable as per I.S : 7098 armoured, served shaelthed 1100v grade with Termination and laying of cable.
20
-
-
Supply of ceiling fan :- Supplying and fitting of 1400mm sweep regular /standard model AC fan, including connection with 1.5 sqmm copper wire down rod of standered length (upto 30cm) with all acessories as required
12
-
-
Led tube with batten 20W/22W :- Supply and fixing of wall mounted LED 20W/22Wtube+batten electronic driver and acessories as required.
12
-
-
Led bulb 9W/10W :- Supplying and fixing of LED 9W/10W bulb and acessories as required.
4
-
-
Add 18% GST (In Basic Rate must fill 18)
0.18
-
-
Add 1% Labour Cess (In Basic must Rate fill 1)
1
-
-
Evaluation Notes How It Works ?