MECON Limited Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

MECON Limited - MECON Tender

Services
Eprocure
Opening Date20 Dec 2024
Closing Soon13 Jan 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Acvs To Bsl (package No. Se-916) Required Forrebuilding Of Coke Oven Battery No. 6 At Sail-bsl

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Condenser cooling pumps & accessories 40 m3/Hr, head 25m, Body: Cast Steel, Impeller : SS

2

-

-

... More
In-line booster fan & accessories

1

-

-

... More
GI Ducting with supports, diffuser, fittings, etc.

1

-

-

... More
Balancing valve at package AC return line

1

-

-

... More
MS heavy class condenser, make up water & drain Piping, pipe fittings, valves & strainer etc.

1

-

-

... More
50 NB MS (Heavy Grade) make up water & drain Piping, pipe fittings, valves etc. ,

1

-

-

... More
Make-up air filter, dampers, cowl & bird mesh

1

-

-

... More
Supply and Return air grill/Diffusers

1

-

-

... More
Strip heater , pan humidifier with piping & controls

1

-

-

... More
Instruments & controls, pressure gauge Thermometer, thermostat, humidistat , geyser stat, water flow Switch, etc.

1

-

-

... More
Acoustic and Thermal duct line Insulation /GI cladding

1

-

-

... More
Under deck thermal insulation of the exposed roof of air conditioning premises

1

-

-

... More
Split Air Conditioners (Min. 3 star rating of BEE)

-

-

-

... More
New GCM Booth-Cum-Waste Analyser Room for Stack- 1 x 2 TR industrial Split AC based air conditioning system consisting of outdoor, indoor unit, refrigerant copper piping, support structure, condensate drain piping, insulation and all other standard accessories.

2

-

-

... More
Flue Booth Room- 1 x 2 TR industrial Split AC based air conditioning system consisting of outdoor, indoor unit, refrigerant copper piping, support structure, condensate drain piping, insulation and all other standard accessories.

1

-

-

... More
CV Analyser Room- 1 x 2 TR industrial Split AC based air conditioning system consisting of outdoor, indoor unit, refrigerant copper piping, support structure, condensate drain piping, insulation and all other standard accessories.

1

-

-

... More
HPALA VFD Enclosure (above HPALA Electrical Room - 1 x 2 TR industrial Split AC based air conditioning system consisting of outdoor, indoor unit, refrigerant copper piping, support structure, condensate drain piping, insulation and all other standard accessories.

5

-

-

... More
Reversing Winch- PLC Room at IB-10 towards CT-3- 1 x 2 TR industrial Split AC based air conditioning system consisting of outdoor, indoor unit, refrigerant copper piping, support structure, condensate drain piping, insulation and all other standard accessories.

2

-

-

... More
NEW OFFICE BUILDING- 1 x 1.5 TR industrial Split AC based air conditioning system consisting of outdoor, indoor unit, refrigerant copper piping, support structure, condensate drain piping, insulation and all other standard accessories.

20

-

-

... More
VENTILATION SYSTEM Main Control Room

-

-

-

... More
Gents Toilet-Gr. Floor- Exhaust Ventilation System Wall mounted Propeller fan (1100cmh) based exhaust ventilation system with motor,cowl, bird screen etc.

1

-

-

... More
Ladies Toilet-First Floor- Exhaust Ventilation System Wall mounted Propeller fan (1100cmh) based exhaust ventilation system with motor,cowl, bird screen etc.

1

-

-

... More
Gents Toilet-Second Floor- Exhaust Ventilation System Wall mounted Propeller fan (1500cmh) based exhaust ventilation system with motor, cowl,bird screen etc.

1

-

-

... More
MCC Room in Coal Tower 3- Gr. FLOOR

-

-

-

... More
MCC Room in Coal Tower 3- Gr. FLOOR- Dry Pressurized Vent System Wall mounted supply Tube Axial Fan (1x3500cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, gravity louver etc.

3

-

-

... More
NEW 1-TP 18 SUBSTATION

-

-

-

... More
Cable Cellar- Dry Pressurized Vent System Wall mounted supply Tube Axial Fan (1x7500cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, gravity louver etc.

2

-

-

... More
Transformer rooms- Exhaust Ventilation System Wall mounted Exhaust Tube Axial Fan (1x7500cmh @ 15mmWC) based exhaust ventilation system with motor, support structure, cowl, bird screen etc

3

-

-

... More
Panel Room- Dry pressurized Vent System Wall mounted supply Tube Axial Fan (1x7500cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, gravity louver & electric etc.

3

-

-

... More
Flue Booth Room

-

-

-

... More
Flue Booth Room- Exhaust Ventilation system Wall mounted Exhaust Tube Axial Fan (1x3000cmh @ 15mmWC) based exhaust ventilation system with motor, support structure, cowl, bird screen etc.

1

-

-

... More
New GCM Booth Cum Waste Gas Ananlyzer Room For Stack

-

-

-

... More
New GCM Booth Cum Waste Gas Ananlyzer Room For Stack- Exhaust Ventilation System Wall mounted Exhaust Tube Axial Fan (1x2500cmh @ 15mmWC) based exhaust ventilation system with motor, support structure, cowl, bird screen etc.

2

-

-

... More
BY PRODUCT ELECTRICAL ROOM BELOW EXHAUSTER HOUSE

-

-

-

... More
BY PRODUCT ELECTRICAL ROOM BELOW EXHAUSTER HOUSE- Dry pressurized Vent System Wall mounted supply Tube Axial Fan (1x5000cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, bird screen, gravity louver etc.

3

-

-

... More
END BENCH 11 ELECTRICAL ROOM-

-

-

-

... More
END BENCH 11 ELECTRICAL ROOM- Dry pressurized Vent System Wall mounted supply Tube Axial Fan (1x4000cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, bird screen, gravity louver etc.

2

-

-

... More
CV Analyzer Room

-

-

-

... More
CV Analyzer Room- Exhaust Ventilation System Wall mounted Exhaust Tube Axial Fan (1x3000cmh @ 15mmWC) based exhaust ventilation system with motor, support structure, cowl, bird screen etc.

1

-

-

... More
HPALA Electrical Room

-

-

-

... More
HPALA Electrical Room- Dry pressurized Vent System Wall mounted supply Tube Axial Fan (1x7500cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, bird screen, gravity louver & electric etc.

2

-

-

... More
Compressed Air Station-

-

-

-

... More
Compressed Air Station- Dry pressurized Vent System Wall mounted supply Tube Axial Fan (1x10000cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, bird screen, gravity louver & electric etc.

3

-

-

... More
HPALA Pump House

-

-

-

... More
HPALA Pump House- Dry pressurized Vent System Wall mounted supply Tube Axial Fan (1x5000cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, , gravity louver etc.

2

-

-

... More
GENERAL SHIFT ELECTRICAL MAINTENANCE ROOM

-

-

-

... More
GENERAL SHIFT ELECTRICAL MAINTENANCE ROOM- Dry pressurized Vent System Wall mounted supply Tube Axial Fan (1x4500cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, bird screen, gravity louver & electric etc.

2

-

-

... More
NEW OFFICE BUILDING

-

-

-

... More
Gents Toilet- Exhaust Ventilation Wall mounted Propeller fan (1100cmh) based exhaust ventilation system with motor, bird screen etc.

1

-

-

... More
Ladies Toilet- Exhaust Ventilation Wall mounted Propeller fan (1100cmh) based exhaust ventilation system with motor, bird screen etc.

1

-

-

... More
Electrical Power Requirement/Provisions of ACVS consisting of all items as indicated in under clause no. 14.00(2) of technical specification

1

-

-

... More
ERECTION, TESTING & COMMISSIONING AIR CONDITIONING SYSTEM Main Control Room:Water Cooled Package Air Conditioners

-

-

-

... More
Water Cooled Package AC Unit 20 or 21 TR nominal capacity, consisting of scroll compressor, cooling coil, refrigerant circuit, condenser, thermostatic expansion valve, blower, air-filter, MCC, electric drives, instruments & control and other standard accessories assembled in a steel cabinet.

3

-

-

... More
Induced draft cooling Tower & accessories (60 TR minimum),

2

-

-

... More
Condenser cooling pumps & accessories 40 m3/Hr, head 25m, Body: Cast Steel, Impeller : SS

2

-

-

... More
In-line booster fan & accessories

1

-

-

... More
GI Ducting with supports, diffuser, fittings, etc.

1

-

-

... More
Balancing valve at package AC return line

1

-

-

... More
MS heavy class condenser, make up water & drain Piping, pipe fittings, valves & strainer etc.

1

-

-

... More
50 NB MS (Heavy Grade) make up water & drain Piping, pipe fittings, valves etc. ,

1

-

-

... More
Make-up air filter, dampers, cowl & bird mesh

1

-

-

... More
Supply and Return air grill/Diffusers

1

-

-

... More
Strip heater , pan humidifier with piping & controls

1

-

-

... More
Instruments & controls, pressure gauge Thermometer, thermostat, humidistat , geyser stat, water flow Switch, etc.

1

-

-

... More
Acoustic and Thermal duct line Insulation /GI cladding

1

-

-

... More
Under deck thermal insulation of the exposed roof of air conditioning premises

1

-

-

... More
Split Air Conditioners (Min. 3 star rating of BEE)

-

-

-

... More
New GCM Booth-Cum-Waste Analyser Room for Stack- 1 x 2 TR industrial Split AC based air conditioning system consisting of outdoor, indoor unit, refrigerant copper piping, support structure, condensate drain piping, insulation and all other standard accessories.

2

-

-

... More
Flue Booth Room- 1 x 2 TR industrial Split AC based air conditioning system consisting of outdoor, indoor unit, refrigerant copper piping, support structure, condensate drain piping, insulation and all other standard accessories.

1

-

-

... More
CV Analyser Room- 1 x 2 TR industrial Split AC based air conditioning system consisting of outdoor, indoor unit, refrigerant copper piping, support structure, condensate drain piping, insulation and all other standard accessories.

1

-

-

... More
HPALA VFD Enclosure (above HPALA Electrical Room - 1 x 2 TR industrial Split AC based air conditioning system consisting of outdoor, indoor unit, refrigerant copper piping, support structure, condensate drain piping, insulation and all other standard accessories.

5

-

-

... More
Reversing Winch- PLC Room at IB-10 towards CT-3- 1 x 2 TR industrial Split AC based air conditioning system consisting of outdoor, indoor unit, refrigerant copper piping, support structure, condensate drain piping, insulation and all other standard accessories.

2

-

-

... More
NEW OFFICE BUILDING- 1 x 1.5 TR industrial Split AC based air conditioning system consisting of outdoor, indoor unit, refrigerant copper piping, support structure, condensate drain piping, insulation and all other standard accessories.

20

-

-

... More
VENTILATION SYSTEM Main Control Room

-

-

-

... More
Gents Toilet-Gr. Floor- Exhaust Ventilation System Wall mounted Propeller fan (1100cmh) based exhaust ventilation system with motor,cowl, bird screen etc.

1

-

-

... More
Ladies Toilet-First Floor- Exhaust Ventilation System Wall mounted Propeller fan (1100cmh) based exhaust ventilation system with motor,cowl, bird screen etc.

1

-

-

... More
Gents Toilet-Second Floor- Exhaust Ventilation System Wall mounted Propeller fan (1500cmh) based exhaust ventilation system with motor, cowl,bird screen etc.

1

-

-

... More
MCC Room in Coal Tower 3- Gr. FLOOR

-

-

-

... More
MCC Room in Coal Tower 3- Gr. FLOOR- Dry Pressurized Vent System Wall mounted supply Tube Axial Fan (1x3500cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, gravity louver etc.

3

-

-

... More
NEW 1-TP 18 SUBSTATION

-

-

-

... More
Cable Cellar- Dry Pressurized Vent System Wall mounted supply Tube Axial Fan (1x7500cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, gravity louver etc.

2

-

-

... More
Transformer rooms- Exhaust Ventilation System Wall mounted Exhaust Tube Axial Fan (1x7500cmh @ 15mmWC) based exhaust ventilation system with motor, support structure, cowl, bird screen etc

3

-

-

... More
Panel Room- Dry pressurized Vent System Wall mounted supply Tube Axial Fan (1x7500cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, gravity louver & electric etc.

3

-

-

... More
Flue Booth Room

-

-

-

... More
Flue Booth Room- Exhaust Ventilation system Wall mounted Exhaust Tube Axial Fan (1x3000cmh @ 15mmWC) based exhaust ventilation system with motor, support structure, cowl, bird screen etc.

1

-

-

... More
New GCM Booth Cum Waste Gas Ananlyzer Room For Stack

-

-

-

... More
New GCM Booth Cum Waste Gas Ananlyzer Room For Stack- Exhaust Ventilation System Wall mounted Exhaust Tube Axial Fan (1x2500cmh @ 15mmWC) based exhaust ventilation system with motor, support structure, cowl, bird screen etc.

2

-

-

... More
BY PRODUCT ELECTRICAL ROOM BELOW EXHAUSTER HOUSE

-

-

-

... More
BY PRODUCT ELECTRICAL ROOM BELOW EXHAUSTER HOUSE- Dry pressurized Vent System Wall mounted supply Tube Axial Fan (1x5000cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, bird screen, gravity louver etc.

3

-

-

... More
END BENCH 11 ELECTRICAL ROOM-

-

-

-

... More
END BENCH 11 ELECTRICAL ROOM- Dry pressurized Vent System Wall mounted supply Tube Axial Fan (1x4000cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, bird screen, gravity louver etc.

2

-

-

... More
CV Analyzer Room

-

-

-

... More
CV Analyzer Room- Exhaust Ventilation System Wall mounted Exhaust Tube Axial Fan (1x3000cmh @ 15mmWC) based exhaust ventilation system with motor, support structure, cowl, bird screen etc.

1

-

-

... More
HPALA Electrical Room

-

-

-

... More
HPALA Electrical Room- Dry pressurized Vent System Wall mounted supply Tube Axial Fan (1x7500cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, bird screen, gravity louver & electric etc.

2

-

-

... More
Compressed Air Station-

-

-

-

... More
Compressed Air Station- Dry pressurized Vent System Wall mounted supply Tube Axial Fan (1x10000cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, bird screen, gravity louver & electric etc.

3

-

-

... More
HPALA Pump House

-

-

-

... More
HPALA Pump House- Dry pressurized Vent System Wall mounted supply Tube Axial Fan (1x5000cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, , gravity louver etc.

2

-

-

... More
GENERAL SHIFT ELECTRICAL MAINTENANCE ROOM

-

-

-

... More
GENERAL SHIFT ELECTRICAL MAINTENANCE ROOM- Dry pressurized Vent System Wall mounted supply Tube Axial Fan (1x4500cmh @ 25mmWC) based ventilation system with motor, support structure, cowl, filters, bird screen, gravity louver & electric etc.

2

-

-

... More
NEW OFFICE BUILDING

-

-

-

... More
Gents Toilet- Exhaust Ventilation Wall mounted Propeller fan (1100cmh) based exhaust ventilation system with motor, bird screen etc.

1

-

-

... More
Ladies Toilet- Exhaust Ventilation Wall mounted Propeller fan (1100cmh) based exhaust ventilation system with motor, bird screen etc.

1

-

-

... More
Electrical Power Requirement/Provisions of ACVS consisting of all items as indicated in under clause no. 14.00(2) of technical specification

1

-

-

... More
OPERATION & MAINTENANCE

-

-

-

... More
All Inclusive” Operation & Maintenance of the ACVS system/equipment, considered under PHASE-I of ACVS PKG which includes any kind of refurbishment / replacement of parts or components or equipment, spares, consumables, manpower and services as may be required for time period of 3 months from date of commissioning of phase-I ACVS system.

3

-

-

... More
All Inclusive” Operation & Maintenance of the ACVS system/equipment, considered under PHASE-II of ACVS PKG which includes any kind of refurbishment / replacement of parts or components or equipment, spares, consumables, manpower and services as may be required for time period of 6 months from date of commissioningof phase-II ACVS system.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.