Jharkhand Urja Sancharan Nigam Limited Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Jharkhand Urja Sancharan Nigam Limited - JUSNL Tender

Works
Civil And Construction
Electrical and Electronics
Consultancy Services
Civil And Architectural Services
Eprocure
Opening Date29 Nov 2024
Closing Date16 Dec 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
200 MVA Three phase power Transformer 220/132/33 KV Auto Transformer Complete with all accessories, marshaling boxes, terminal connectors etc. with NIFPS with 10% additional Transformer Oil of same quality

2

-

-

... More
LT TRANSFORMER

-

-

-

... More
630 KVA 33/0.433KV LT SUBSTATION TRANSFORMER with oil,accessories and terminal connectors with 10%extra oil.

2

-

-

... More
220 kV EQUIPMENT

-

-

-

... More
Circuit breaker (3 phase)

-

-

-

... More
2500 A, 40 kA SF6 CB with support structure, marshalling boxes, terminal connectors etc.(current rating shall be equal to the current rating for which the short cuircuit test reports shall be furnished. (Spring- Spring Mechanism ) (spring- spring )

8

-

-

... More
ISOLATORS (3 phase), with solid core insulators, marshalling boxes, terminal connectors (Motor Operated) with moving contact of HDEC copper only.

-

-

-

... More
1600 A, 40 kA with two earth switch (Double break Isolator)

9

-

-

... More
1600 A, 40 kA with one earth switch (Double break Isolator)

8

-

-

... More
1600 A, 40 kA without earth switch (Double break Isolator) (Tandem arrangement)

14

-

-

... More
2500 A, 40 kA with two earth switch (Double break Isolator)

2

-

-

... More
CURRENT TRANSFORMER 5 Core (1 phase) WITH MARSHALING BOXES TERMINAL CONNECTORS

-

-

-

... More
1600-800-400-200/1-1-1-1-1 A, 120% extended current rating, 40 kA, 0.2 class 5 core

27

-

-

... More
220 KV CVT 4400 pF CVTs (1 phase) for phase to phase coupling with all accessories, terminal connectors etc.

21

-

-

... More
216 kV Surge Arresters (1 phase) class-III with terminal connectors.

18

-

-

... More
Portable discharge rods

6

-

-

... More
ERECTION HARDWARE (220 kV)

-

-

-

... More
Erection Hardware (Without BPI)

-

-

-

... More
Insulator strings antifog type & hardware, spacers, conductor (S), Bus bar material, galvanised cable trays/ cable rack, bay MB, Clamps, Connectors including, Junction box,PVC pipes for equipment and lighting, all accessories etc. for the following (The main I & main II buses shall be of quad Moose ACSR Conductor & TBC as well as Bus Coupler will be of double Moose conductor.

-

-

-

... More
220 kV, Double Main & Transfer bus type

-

-

-

... More
Line bay

4

-

-

... More
Transformer bay

2

-

-

1

-

-

... More
BC Bay

1

-

-

... More
Bus Extension for 10 Bays (one no each for main I, main II & trasfer bus)

3

-

-

... More
220 kV Solid Core, Bus post Insulators (including requirement for wave trap)

115

-

-

... More
132 kV EQUIPMENT

-

-

-

... More
Circuit breaker (3 phase)

-

-

-

... More
1600 A, 31.5 kA SF6 CB with support structure, marshalling boxes, terminal connectors etc.(current rating shall be equial to the current rating for which the short cuircuit test reports shall be furnished.) (Spring- Spring )

7

-

-

... More
ISOLATORS (3 phase), with solid core insulators, marshaling boxes, terminal connectors (Motor Operated) with moving contact of HDEC copper only.

-

-

-

... More
1600 A, 31.5 kA with one earth switch (Double break Isolator)

6

-

-

... More
1600A, 31.5 kA without earth switch (Double break Isolator)

8

-

-

... More
1600 A, 31.5 kA without earth switch (Double break Isolator)(Tandem arrangement)

7

-

-

... More
2000 A, 31.5 kA without earth switch (Double break high level beam mounted Isolator)

2

-

-

... More
Portable discharge rods ( 1 phase)

6

-

-

... More
Current Transformers 5 core (1 phase)

-

-

-

... More
1200 -600-300-150/1-1-1-1-1 A, 5 core 0.2S class ,31.5 kA with 120% extended current rating with marshalling boxes, terminal connectors etc.

21

-

-

... More
8800 pF CVTs (1 phase) with marshalling boxes, terminal connectors etc .

15

-

-

... More
120 kV Surge arresters class-III ( 1 phase) with marshalling boxes, terminal connectors etc.

18

-

-

... More
ERECTION HARDWARE (132 kV)

-

-

-

... More
Insulator strings antifog type & hardware, spacers, conductor (S), Bus bar material, galvanised cable trays/Cable rack, bay MB, Clamps, Connectors including, Junction box,PVC pipes for equipment and lighting, all accessories etc. for the following (main bus shall be of quad Moose conductor and transfer bus shall be strung with double Moose conductor)

-

-

-

... More
132 kV Main & Transfer bay

-

-

-

... More
Line bay

4

-

-

... More
Transformer bay

2

-

-

... More
TBC Bay

1

-

-

... More
Bus for 8 bays (One for main bus & another for transfer bus)

2

-

-

... More
132 kV Solid Core, Bus post Insulators for erection hardware

53

-

-

... More
33 kV EQUIPMENT

-

-

-

... More
Circuit Breaker (3 Phase)

-

-

-

... More
1600 A, 25KA Vacume CB with support structure, marshalling boxes, terminal connectors etc. (current rating shall be equail to the current rating for which the short circuit test report shall be furnished) (Spring-Spring)

2

-

-

... More
ISOLATORS (3 phase), with solid core insulators, marshalling boxes, terminal connectors (Manually operated) with moving contact of HDEC copper only.

-

-

-

... More
1600 A, 25 kA without earth switch (Double break Isolator)

2

-

-

... More
1200A, Horn gap fuse ( 1 phase)

6

-

-

... More
Current Transformers (1 phase)

-

-

-

... More
600-300-150/1 A, 5 core 0.2 class 25 kA with 120% extended current rating with marshalling boxes terminal connectors

6

-

-

... More
30 kV Surge arresters class 3 ( 1 phase) with marshalling boxes terminal connectors

6

-

-

... More
33 kV Solid core Bus post Insulators for erection hardware

6

-

-

... More
LT Switchgear

-

-

-

... More
415 V Main switch Board

2

-

-

... More
415 V ACDB (no of feeders shall be asper the requirement of the project plus 20% extra feeders)

2

-

-

... More
415V MLDB

2

-

-

... More
415V Emergency LDB

2

-

-

... More
250V DCDB (no of feeders shall be asper the requirement of the project plus 20% extra feeders)

2

-

-

... More
48V DCDB

2

-

-

... More
CONTROL & RELAY PANELS

-

-

-

... More
220 kV (Simplex panels)

-

-

-

... More
Control Panel for two bays with All indicating meters/ multifunctions meters shall be communicable type with 0.2 class accuracy.

4

-

-

... More
CB relay panel with A/R

4

-

-

... More
CB relay panel without A/R

4

-

-

... More
Line protection panel with numerical distance protection relays and earth fault / overcurrent relays complying to IEC 61850 Protocal with optical fiber ports sufficient DI/DO ports for scheme with additional 6 DI/DO Ports for spare.

4

-

-

... More
Transformer protection panel HV and LV sides) with numerical differential protecton relays with earth fault/ over current relay complying to IEC 61850 Protocal with optical fiber ports and sufficient DI/DO for scheme with additional 6 DI/DO ports for spare.

2

-

-

... More
Bus Bar Protection Panel ( will be integrated type and will have min. 4 zone with numerical type relay)

1

-

-

... More
Transfer bus coupler panel with distance protection relay scheme with all relays

1

-

-

... More
Time synchonization eqp. Will have dual ethernet with RJ 45 port

1

-

-

... More
132 kV (Simplex Panels)

-

-

-

... More
132KV Control, Relay & Protection Panel (Simplex Types Panels)

-

-

-

... More
CB panel with BCU (Line and Transfer coupler)

5

-

-

... More
CB panel with BCU (Transformer)

2

-

-

... More
132 KV line (with A/R) with numerical distance protection relays and earth fault / overcurrent relays complying to IEC 61850 Protocal with optical fiber ports sufficient DI/DO for scheme with additional 6 DI/DO for spare. All indicating meters/ multifunctions meters shall be communicable type with 0.2 class accuracy.

4

-

-

... More
132/33 KV Transformer (without A/R) with numerical differential protection relays and earth fault / overcurrent relays complying to IEC 61850 Protocal with optical fiber ports sufficient DI/DO for scheme with additional 6 DI/DO for spare.

2

-

-

... More
132 kV TBC (with A/R) with numerical distance protection relays and earth fault / overcurrent relays complying to IEC 61850 Protocal with optical fiber ports sufficient DI/DO for scheme with additional 6 DI/DO for spare. All indicating meters/ multifunctions meters shall be communicable type with 0.2 class accuracy.

1

-

-

... More
Transformer ( CB relay Panel without A/R )

2

-

-

... More
33 KV CONTROL & RELAY PANELS

-

-

-

... More
33 kV Panels (Duplex)

-

-

-

... More
Control, Relay & Protection Panel for

-

-

-

... More
Line with numerical type E.F & O/C relays complying to IEC 61850 protocol

2

-

-

... More
FOTE Fiber Optic Terminal Equipment based communication system for all 220KV and 132KV Terminal lines including spare bay, approach cable, RTU Communication Modules, interfacing with SLDC (for speech + protection and for speech + data), PDH/SDH etc all complete along with for GSS end

1

-

-

... More
BATTERIES (VRLA TYPE)

-

-

-

-

-

-

... More
500 AH

2

-

-

-

-

-

... More
500 AH

2

-

-

... More
BATTERY CHARGER SYSTEM chloride

-

-

-

... More
250 V, 60A/50A Float and float Cum Boost Charger

2

-

-

... More
48 V, 60A/50A Float and float Cum Boost Charger

2

-

-

... More
FIRE PROTECTION SYSTEM

-

-

-

... More
Portable Fire Extinguishers

-

-

-

... More
4.5 Kg DCP Type

20

-

-

... More
4.5 Kg CO2 Type

15

-

-

... More
22.5 Kg CO2 type

10

-

-

... More
12 Fire buckets with stand

5

-

-

... More
Complete pumping arrangement for HVWS system & hydrant system, complete with all piping, valves, fittings, etc. inside pump house. (Pump house separate from control room as well as water storage tank to be constructed)

4

-

-

... More
Smoke detection system with all accessories and fittings

3

-

-

... More
Hydrant system with complete U/G & O/G piping & accessories etc. (all items) out side the Pump House. Hydrant system shall cover the switchyard area, Transformers, control room, Stores etc. as per tender specification.

1

-

-

... More
Complete HVW spray system with complete O/G & U/G piping and accessories etc. (all items) with all required materials and equipments out side the pump house for 200 MVA, 2 Nos,220/132/33 KV power transformers as per tender specification.

1

-

-

... More
ILLUMINATION SYSTEM

-

-

-

... More
CONTROL ROOM BUILDING:

-

-

-

... More
Lighting Panel

-

-

-

... More
Lighting Panel (Indoor) Type ACP-1 as per Tech. Specification

2

-

-

... More
Lighting Panel (Indoor) Type DCP as per Tech. Specification

1

-

-

... More
Lighting fixtures and receptacles (including accessories/ materials etc. as per requirement like junction box, cable/wires, flexible conduits (if required) from junction box to lighting fixtures, mounting arrangements)

-

-

-

... More
Lighting fixture Type- F1 as per Tech. Specification

50

-

-

... More
Lighting fixture Type- FF: as per Tech. Specification

100

-

-

... More
Lighting fixture Type- IF: as per Tech. Specification

30

-

-

... More
Lighting fixture Type- FB: as per Tech. Specification

30

-

-

... More
Lighting fixture Type- PF: as per Tech. Specification

5

-

-

... More
5/15 A, 240V: Indoor Receptacles 3 pin type (type RI)

20

-

-

... More
15A, 240V: Out door receptacles 2 pole, 3 pin type (Type RO)

2

-

-

... More
63A, 415V : Interlocked switch socket outdoor Receptacles (Type RP)

2

-

-

... More
Switchboards

-

-

-

... More
Modular switch board with 4 nos. 5Amp. Switches and 1 no. 5/15 Amp. receptacles

10

-

-

... More
Modular switchboard with 6 nos. 5Amp. Switches

10

-

-

... More
Modular switchboard with 2 nos. 5Amp. Switches

10

-

-

... More
Modular switchboard with 6 nos. 32 Amp MCB

5

-

-

... More
Modular switchboard with 1 no. 32 Amp. MCB

5

-

-

... More
Ceiling fans

-

-

-

... More
1400 mm sweep with electronic step regulator

28

-

-

... More
Exhaust fans (16') Indristrial Type

10

-

-

... More
Wall mounted fans 400 mm sweep

2

-

-

... More
Conduits & wires

-

-

-

... More
Heavy duty PVC conduits as of 20/25/32 mm size complete with all accessories for point wiring for Light points, Fans power points 5/15 amps. With 2.5 sq.mm/4 mm2/6.0 mm2 copper for circuit wiring and 1.5 mm2 copper earth wire PVC insulated in green color including wiring for submains i.e. wiring from Lighting panel to switch board.

1

-

-

... More
Wiring from lighting panel to switch boards, from switchboard to junction boxes for light points with 2.5/4.0/6.0 mm2 copper wire as per technical specification, complete in all respect. 1.5 mm2 copper wire (green) will be used for earthing inside conduits

1

-

-

... More
Telephone sockets

-

-

-

... More
Single socket outlet comprising RJ-11 socket

10

-

-

... More
Dual socket outlet comprising RJ-45 socket

5

-

-

... More
EPAX (24/8) with 24 telephones

1

-

-

... More
Junction boxes with 4 nos. of terminal blocks for indoor lighting excluding junction box supplied alongwith lighting fixture

2

-

-

... More
Lighting Transformer 630 kVA, 33/0.433KV LT Transformer with oil , accessories and as per Tech. Specification.

2

-

-

... More
Self supported aluminium ladder as per technical specification

3

-

-

... More
Air Conditioning System (as per technical specification)

-

-

-

... More
Air conditioning of control room building with high wall type 5 star rated split air conditioner unit of 2 TR capacity with stabilizer

50

-

-

... More
FFPH Building

-

-

-

... More
Lighting fixtures and receptacles (including accessories/ materials etc. as per requirement like junction box, cable/wires, flexible conduits (if required) from junction box to lighting fixtures, mounting arrangements)

-

-

-

... More
Lighting fixture Type- F1: as per Tech. Specification

25

-

-

... More
Lighting fixture Type- IF: as per Tech. Specification

7

-

-

... More
Lighting fixture Type- FB: as per Tech. Specification

12

-

-

... More
Lighting fixture Type- PF: as per Tech. Specification

3

-

-

... More
5/15 A, 240V: Indoor Receptacles 3 pin type (type RI)

5

-

-

... More
Switchboards

-

-

-

... More
Modular switch board with 4 nos. 5Amp. Switches and 1 no. 5/15 Amp. receptacles

7

-

-

... More
Modular switchboard with 2 nos. 5Amp. Switches

5

-

-

... More
Ceiling fans

-

-

-

... More
1400 mm sweep with electronic step regulator

2

-

-

... More
Exhaust fans (16') Indristrial Type

4

-

-

... More
Wall mounted fans 400 mm sweep

4

-

-

... More
Conduits & wires

-

-

-

... More
Heavy duty PVC conduits as of 20/25/32 mm size complete with all accessories for point wiring for Light points, Fans power points 5/15 amps. With 2.5 sq.mm/4 mm2/6.0 mm2 copper for circuit wiring and 1.5 mm2 copper earth wire PVC insulated in green color including wiring for submains i.e. wiring from Lighting panel to switch board.

1

-

-

... More
Wiring from lighting panel to switch boards, from switchboard to junction boxes for light points with 2.5/4.0/6.0 mm2 copper wire as per technical specification, complete in all respect. 1.5 mm2 copper wire (green) will be used for earthing inside conduits

1

-

-

... More
Junction boxes with 4 nos of terminal blocks for indoor lighting excuding junction box supplied alongwith lighting fixtures.

2

-

-

... More
Outdoor lighting (Switchyard and street lighting)

-

-

-

... More
Lighting panel

-

-

-

... More
Lighting panel (Outdoor) Type ACP - 2

8

-

-

... More
Lighting panel (Outdoor) Type ACP - 3

3

-

-

... More
Lighting fixtures and receptacles (including accessories/ materials etc. as per requirement like junction box, cable/wires, flexible conduits (if required) from junction box to lighting fixtures, mounting arrangements)

-

-

-

... More
Lighting fixture Type- SF1: as per Tech. Specification

20

-

-

... More
Lighting fixture Type- SF2: as per Tech. Specification

30

-

-

... More
Lighting fixture Type- MP: as per Tech. Specification

6

-

-

... More
Lighting fixture Type- SC: as per Tech. Specification

35

-

-

... More
15A, 240V : Outdoor receptacles 2 pole, 3 pin type (Type RO)

10

-

-

... More
63A, 415V: Interlocked switch socket outdoor receptacles (Type RP)

10

-

-

... More
Lighting poles Type A1

50

-

-

... More
Lighting poles Type E1

20

-

-

... More
Cart wheel mounted aluminium ladder as per Tech. Specification

1

-

-

... More
Diesel Generator Set along with Control Panel (250 KVA)

1

-

-

... More
Cables alongwith associated accessories like clamps, glands, lugs and straight joints etc.

-

-

-

... More
Power cables (XLPE) 1.1 kV

-

-

-

... More
1C X 630 mm2

1

-

-

... More
3.5C X 300 mm2

1

-

-

... More
3.5C X 150 mm2

1

-

-

... More
1C X 150 mm2

1

-

-

... More
Power cables (PVC) 1.1 kV

-

-

-

... More
3.5C X 70 mm2

1

-

-

... More
3.5C X 35 mm2

1

-

-

... More
4C X 16 mm2

1

-

-

... More
4C X 6 mm2

1

-

-

... More
2C X 6 mm2

1

-

-

... More
Control cable (PVC) 1.1 kV

-

-

-

... More
2C X 2.5 mm2

1

-

-

... More
3C X 2.5 mm2

1

-

-

... More
5C X 2.5 mm2

1

-

-

... More
7C X 2.5 mm2

1

-

-

... More
10C X 2.5 mm2

1

-

-

... More
14C X 2.5 mm2

1

-

-

... More
19C X 2.5 mm2

1

-

-

... More
27C X 2.5 mm2

1

-

-

... More
Materials for earthing mat with all materials and accessories as well as spikes as per requirement of design as per IEEE standards for complete earthing of grid Sub-Station with the followings. (The quantity is tentative and final quantity will depend on actual design):-

-

-

-

... More
40 mm MS rod for main earth mat including treated chemical type earthpits.

65

-

-

... More
75x12 mm G.I Flats for risers for equipments, columns and structures

55

-

-

... More
50x6 mm G.I flats for risers for all other equipments etc.

50

-

-

... More
Materials for Earthing pits with supply of all earthing materials including base plate.

1

-

-

... More
Sub- Station galvanized Steel structure (220 kV, 132 KV ) (The quantity is tentative and final quantity will depend on actual design):-

-

-

-

... More
Lattice structure with fasteners etc.

470

-

-

... More
Standard structure for equipment support (other than CB)

210

-

-

... More
Mandatory spares (As per Tech, Specification)

-

-

-

... More
220/132 kV, 200 MVA Transformer

1

-

-

... More
220 kV CB

1

-

-

... More
132 kV CB

1

-

-

... More
220 kV Isolator

1

-

-

... More
132 kV Isolator

1

-

-

... More
220 kV CT, 1600A, 120% extended current rating

3

-

-

... More
220 kV CT, 1600A, 150% extended current rating

3

-

-

... More
132 kV CT, 1200A, 120% extended current rating

3

-

-

... More
132 KV CT 600A 120% extended

3

-

-

... More
220 kV CVT, 4400 pF

3

-

-

... More
132 kV CVT, 8800 pF

3

-

-

... More
216 kV surge arrester

3

-

-

... More
120 kV surge arrester

3

-

-

... More
C&R Panels

1

-

-

-

-

-

... More
Batteries (250V & 48V)

1

-

-

... More
Battery Charger (250 V & 48 V)

1

-

-

... More
DG Set

1

-

-

... More
LT Switchgear

1

-

-

... More
Fire fighting System

1

-

-

... More
Erection Hardware

1

-

-

... More
Illumination

1

-

-

... More
Maintenance & Testing equipment for CB and transformer comprising of the following equipments:(As per Tech Specification)

-

-

-

... More
BDV Test kit (2.5/4 mm) - 100 KV Microprocessor based (Reputed Make)

1

-

-

... More
Mobile switchyard equipment testing van(Having all equipments from single OEM, they should function in integerated way altogether)

1

-

-

... More
Digital multimeter (3½ digit)

1

-

-

... More
Oil sampling bottle (Stainless steel)

2

-

-

... More
Portable SF6 gas refilling device

1

-

-

... More
Dew point kit for SF6 gas. (Reputed make)

1

-

-

... More
SF6 gas evacuating, filtering and drying plant

1

-

-

... More
Transformer oil filtration plant (4 KL / Hr. capacity) complete with all accessories

1

-

-

... More
Circuit breaker analyser (reputed make)

1

-

-

... More
Primary current injection kit (reputed make)

1

-

-

... More
Secondary current injection kit

1

-

-

... More
Relay operation timer (reputed make)

1

-

-

... More
Selective level meter

1

-

-

... More
Selective level generator

1

-

-

... More
Distance to fault locator (off line) with Signature Analyzer System suitable for 66 KV to 400 KV EHT line.

1

-

-

... More
Tongue tester/ Clamp meter (Range 10-1000A)

1

-

-

... More
Tongue tester (Range 10mA-10A)

1

-

-

... More
Thermovision Camera High end (640 x 480 Pixel)

1

-

-

... More
DC Earth Fault Locator

1

-

-

... More
Galvanised Cable Racks as per design requirement.

25

-

-

... More
Sub- Station automation system comprising of necessary equipments & materials wth networking and interfacing, complete in all respect (Break up of item to be given by contractor in technical data sheet with Part-I of the tender)whereever applicable, the communication protocol shall be preferably IEC61850 along with system furniture etc.

1

-

-

... More
Overhead shielding

-

-

-

... More
Overhead shielding against lightning by galvanized steel wires and fittings as per requirement and design (excluding lighting cum lightning mast)

1

-

-

... More
Lighting cum lightning masts as per design

6

-

-

... More
Air condltioning (2Ton)System as per technical Specification.

-

-

-

... More
Switchyard panel Room

-

-

-

... More
220 KV (2 nos.)

4

-

-

... More
132 KV (3 nos.)

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.