Jharkhand Urja Sancharan Nigam Limited Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Jharkhand Urja Sancharan Nigam Limited - JUSNL Tender

Works
Electrical and Electronics
Eprocure
Opening Date27 Feb 2024
Closing Date19 Mar 2024
Tender Amount₹ 35,68,101 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
33 KV Bay-Nut bolt tightening, vAdjustment of Contacts (male/ female) Cleaning, Greasing, Mobilization, & jelly putting in Clamp & connectors, Earthing Flat, Jumpers and other equipments related with Insulators, Isolators, CT, PT, CB, LA, dropping, and panel of a Bay.

20

-

-

... More
132 KV Half Main Bus-Nut bolt tightening, Adjustment, Cleaning, greasing, mobilization, & jelly putting in Clamp & connectors, Earthing Flat, Jumpers and other equipments related with Insulators, Isolators, PT.

4

-

-

... More
132 KV Transfer Bus-Nut bolt tightening, Adjustment, Cleaning, greasing, mobilization, & jelly putting in Clamp & connectors, Earthing Flat, Jumpers and other equipments related with Insulators, Isolators, PT.

2

-

-

... More
220 KV Half Main Bus-Nut bolt tightening, Adjustment, Cleaning, greasing, mobilization, & jelly putting in Clamp & connectors, Earthing Flat, Jumpers and other equipments related with Insulators, Isolators, PT.

8

-

-

... More
220 KV Transfer Bus-Nut bolt tightening, Adjustment, Cleaning, greasing, mobilization, & jelly putting in Clamp & connectors, Earthing Flat, Jumpers and other equipments related with Insulators, Isolators, PT.

2

-

-

... More
Transformer-Nut bolt tightening,Cleaning, in Clamp & connectors, Earthing Flat, Jumpers, silica gel filling, and other equipments related with transformer body.

8

-

-

... More
33 KV Half Main Bus-Nut bolt tightening,Adjustment, Cleaning, Greasing, Mobilization, & jelly putting in Clamp & connectors, Earthing Flat, Jumpers and other equipments related with Insulators, Isolators, PT.

2

-

-

... More
33 KV Transfer Bus-Nut bolt tightening, Adjustment, Cleaning, Greasing, Mobilization, & jelly putting in Clamp & connectors, Earthing Flat, Jumpers and other equipments related with Insulators, Isolators,PT.

2

-

-

... More
SST-Nut bolt tightening,Adjustment, Cleaning, Clamp & connectors ,Earthing Flat, Jumpers and other equipments related with SST body.

2

-

-

... More
Transformer- IR value measurement,

6

-

-

... More
Transformer- BDV measurement,

6

-

-

... More
Circuit Breaker- IR value measurement,

26

-

-

... More
CT[of a bay]- IR value measurement,

26

-

-

... More
LA [of a bay]- IR value measurement,

26

-

-

... More
PT [Set]- IR value measurement,

6

-

-

... More
Measurement & Testing of Transmision Line- Using Fault Locator or any other Device

6

-

-

... More
Measurement & Testing of CB and relay- Using CT Injection Kit or any other Device

8

-

-

... More
Measurement & Testing of Any Grid Equipment- Using Any Kit available in JUSNL or Grid

7

-

-

... More
Maintenance/Emergency Maintenance of Grid Substation as per schedule and JOB provided by Engineer Incharge

-

-

-

... More
Replacement of Nut-Bolts

30

-

-

... More
Replacement of Jumper (conductor/ strip)

20

-

-

... More
Replacement of Clamp & connectors/PG/jumper conia

15

-

-

... More
Replacement of Female contact

15

-

-

... More
Replacement of Female contact base

15

-

-

... More
Replacement of Isolator Blade

10

-

-

... More
Replacement of Isolator Blade base

10

-

-

... More
Replacement of Female contact at High level

5

-

-

... More
Replacement of Isolator Blade at High level

5

-

-

... More
Replacement of Insulators

10

-

-

... More
Replacement of 220 KV or 132KV CT/PT Junction Box including cable terminationn& connection

5

-

-

... More
Replacement of 132KV CB pole

4

-

-

... More
Replacement of 220 KV CB pole

4

-

-

... More
Replacement of 33 KV CT

10

-

-

... More
Replacement of 33 KV PT

2

-

-

... More
Replacement of 33 KV CT/PT Junction Box including cable terminationn& connection

5

-

-

... More
Replacement of 33 KV LA

10

-

-

... More
Replacement of 33 KV CB pole

5

-

-

... More
Minor Repairing of Trasformer- Meggering with opening of bushing connectors , checking of PRV, vent pipe & Buchholz relay, oil top-up etc….. including all or any.

6

-

-

... More
Minor Repairing of CT- Meggering,Opening top cover, replacement of Gasket & CT Stud , oil topup etc..including all or any

6

-

-

... More
Minor Repairing of PT- Meggering,Opening top cover, replacement of Gasket & PT Stud , oil topup etc..including all or any

6

-

-

... More
Minor Repairing of CB-Meggering,Gas filling, checking of MCB, contactors, motor, spring and tripping or closing coils, SF6 gas filling etc… including all or any.

10

-

-

... More
Minor Repairing of Isolator-Adjustment of contacts & moving part etc…

25

-

-

... More
Minor Repairing of Panel- looping & wiring of cabels, loose contact rectification, replacement of lugs,ferrules etc…

7

-

-

... More
Filling of SF6 Gas

10

-

-

... More
Fixing and replacement of Earthing copper bond/Flat

10

-

-

... More
Fixing and replacement of Energy Meter/ MW Meter/ Voltmeter/ Ammeter/ Relay

4

-

-

... More
MISC Work of Grid Substation as per schedule and JOB provided by Engineer Incharge

-

-

-

... More
Battery system cleaning

12

-

-

... More
Cleaning of panels (including all 132KV panel, 220 KV panel ,ACDB, DCDB,etc)

12

-

-

... More
Rectification of Lighting and auxiliary power supply in Grid premises & Colony

40

-

-

... More
Material/ equipment manual shifting & movement in Grid Premises

4

-

-

... More
Laying of Control Cable

1000

-

-

... More
Measurement of Earth Footing resistance of all earth pits

2

-

-

... More
Break down Maintenance

-

-

-

... More
Mobilization/Demobilization of Labour Gang

2

-

-

... More
supply of Emergency Gang with T&P for work like Conductor snapping of main bus

2

-

-

... More
Supply of Hydra / Crane(upto 8MT Capacity ) as per requirement

4

-

-

... More
Complete Overhauling with painting of 150 MVA Transformer Cooling Fans with supply of all materials if required

36

-

-

... More
Transportation of materials by Small / Medium size truck from transmission central stores Namkum or other GSS within 100KM radius to GSS Hatia - II.

8

-

-

... More
Repair and Overhauling of 3ph Sub-mersible pump including materials, lifting & lay down of Sub-mersible pump from Borewell , repair of water supply pipe all complete job & Transporation cost.

2

-

-

... More
Repair of 220 KV SF6 Breaker Air Compressor motor if required

4

-

-

... More
Repair of 220 KV SF6 Breaker 3Φ Phase motor if required

4

-

-

... More
Repair of 220 KV SF6 Breaker 1Φ spring charged motor if required

4

-

-

... More
Repair of 132 KV VCB 1Φ spring charged motor if required

4

-

-

... More
Repair of 33 KV VCB 1Φ spring charged motor if required

4

-

-

... More
Erection, Connection, Testing & Commissioning all Complete work of

-

-

-

... More
220 KV Circuit Breaker including cable termination.

1

-

-

... More
220 KV Current Transformer, Potential Transformer & CVT including cable terminiation

6

-

-

... More
220 KV Isolator Complete Set

2

-

-

... More
220 KV Lightning Arrester

4

-

-

... More
132 KV Circuit Breaker including cable termination.

2

-

-

... More
132 KV Current Transformer, Potential Transformer & CVT including cable terminiation

6

-

-

... More
132 KV Isolator Set

2

-

-

... More
132 KV Lightning Arrester

4

-

-

... More
33 KV Vaccum CB including Cable termination

4

-

-

... More
Dismentaling of following equipments with crane/derrick at site including handling the material/equipment carefully at site including labour charges for all incidental and operational items of work (Excluding Cost of Transporation charges from Store to Site)

-

-

-

... More
220 KV Circuit Breaker including cable termination.

1

-

-

... More
220 KV Current Transformer, Potential Transformer & CVT including cable terminiation

6

-

-

... More
220 KV Isolator Complete Set

2

-

-

... More
220 KV Lightning Arrester

4

-

-

... More
132 KV Circuit Breaker including cable termination.

2

-

-

... More
132 KV Current Transformer, Potential Transformer & CVT including cable terminiation

4

-

-

... More
132 KV Isolator Set

2

-

-

... More
33 KV VCB

4

-

-

... More
Testing of Transformers/1CTs including Tan Delta Test of all bushing & winding, winding resistance test, turn ratio test, magnetic balance test, short & open circuit test , IR & Pl test etc. (All test report must be prepared & submitted in standard format)

-

-

-

... More
220/132 KV 150 MVA ICT

2

-

-

... More
132/33 KV 50 MVA Power Transformer

2

-

-

... More
Testing of Transformer oil by recognized laboratory including supply of sampling bottle.(These tests are mandetory and must be completed by the end of December, 2024)

-

-

-

... More
BDV

3

-

-

... More
DGA

3

-

-

... More
Water content PPM

3

-

-

... More
Furan Analysis

2

-

-

... More
Contingency (Including Sampling Bottle, DD Cost To & Fro Charges with fooding & lodging)

1

-

-

... More
Air conditioner Maintenance Charges

-

-

-

... More
Service Charge for Indoor & Outdoor unit

29

-

-

... More
Gas Filling Charges in Air Conditioner

29

-

-

... More
AC Compressor supply and installation

5

-

-

... More
Supply of Stabilizer of AC

5

-

-

... More
Maintenance of 100KVA DG Set (replacement of Air & fuel filter, Gasket valve cover, engine tube oil etc.)

1

-

-

... More
Assesment of defects in Battery chargers.

2

-

-

... More
Supply of consumables and rectification of Battery charger set including Battery bank.

2

-

-

... More
Supply of Consumables viz. Markin cloth, Distilled water, Grease, Mobil, Nuts & Bolts, Cotton waste, Joute, Paterollium Jelly, Kerosine, mobil, WD-40 rust remover etc. required time to time for O&M works of GSS.

12

-

-

... More
Manager (Tech)

-

-

-

... More
Transmission Sub-Division

-

-

-

... More
Burmu

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.