Jharkhand Urban Infrastructure Development Company Limited Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Jharkhand Urban Infrastructure Development Company Limited Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date22 Feb 2024
Closing Date30 Apr 2024
Tender Amount₹ 61,41,40,760 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lift 2.5 to 3.0 M

72.6

-

-

... More
Earthwork in excavation of foundation trenches of toe wall, spillway, head regulator, outlet, intake well etc. as per designed section in hard rock where blasting is needed & stacking properly in approved stack size in approved stack yard (beyond 50m from the edge of the trenches in the country side) with initial lead of 150 m & initial lift of 1.50m as per specification & direction of E/I (Excavated hard rock size should not be more than 150 lb.)

-

-

-

... More
Lift 3.0 to 3.5 M

67.36

-

-

... More
Lift 3.5 to 4.5 M

119.73

-

-

... More
Lift 4.5 to 5.5 M

101.13

-

-

... More
Lift 5.5 to 6.15 M

56.52

-

-

... More
Earthwork in excavation (as per I.S. 3114/1965 for laying of different type and sizes of pipe so as to give one meter avarage cover over the socket of pipes with disposal of excavated with in initial lead and lift as per specification and direction of engineer-in charge.

-

-

-

... More
For Classification of Soil Item -A

33566.83

-

-

... More
For Classification of Soil Item -B

23683.88

-

-

... More
Earthwork in excavation of cut-off trenches by the hydraulic excavator as per designed section in soft rock (Where blasting is not needed) (vide type of soil item -C) with disposal of soil beyond 1/2 km from centre of trench but upto 1 km with all lifts by tipper including construction and maintenanceof haul road all complete as per specification & direction of E/I .

-

-

-

... More
Excavation in Hard Strata

10070.15

-

-

... More
Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth so obtained to a distance upto 50 M including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I.

833.84

-

-

... More
E/W in excavation in foundation trenches in foundation trenches in ordinary soil (vide classification of soil item B) & disposal of excavated earth obtained to a distance up to 50M including all lift OR BCD leveling, ramming the foundation trenches removing root of trees, shrubs all complete as per approved design.

308.11

-

-

... More
Earthwork in backfilling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-charge.

62562.74

-

-

... More
Supplying equipment and labour for back filling the excavated earth around steining well all complete as per specification and direction of E/I.

506.69

-

-

... More
Filling in foundation trenches & plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted & fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M & lift of 1.5 M all complete as per building specification & direction of E/I.

116.64

-

-

... More
Providing Course Clean Sand in Filling In Foundation Trenchesor in plinth including ramming and watering in layers not exceeding 150mm thick with all leads & lifts including cost of meterials,labours,royalty & taxes all complted as per bulding specification & direction of E/I

529.69

-

-

... More
RCC/PCC

-

-

-

... More
Providing & casting in situ cement concrete of trap/ granite/ quartzite/ gneisis metal of approved quality for RCC work as per detailed drawings and designs as directed by Engineer-in-charge including normal dewatering, plywood form work, bully/steel prop-ups, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing etc complete.(By weigh batching and mix design for M-250 and M-300 only. Use of L and T, A.C.C. Ambuja, Birla Gold, Manikgad, Rajashree, etc cement is permitted.) (excluding M.S. or Tor reinforcement.)

2.77

-

-

... More
Providing & casting in situ cement concrete of trap/ granite/ quartzite/ gneisis metal of approved quality for RCC work as per detailed drawings and designs as directed by Engineer-in-charge including normal dewatering, plywood form work, bully/steel prop-ups, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing etc complete.(By weigh batching and mix design for M-250 and M-300 only.Use of L and T, A.C.C. Ambuja, Birla Gold, Manikgad, Rajashree, etc cement is permitted.) (excluding M.S. or Tor reinforcement.)

10

-

-

... More
Providing & laying PCC M-150 with nominal mix of (1:3:6) in foundation with approved quality of stone metal grade -III (50 mm to 25 mm size ) clean coarse sand FM (2.5 to 3.0) washed and screened excluding cost of shuttering or form work as well as reinforcement, its cutting bending,binding and placing but including necessary tools & plants & vibrating,curing, royalty all taxes etc.complete job as per specification & direction of E/I. PCC - M15

49.8

-

-

... More
Plain/Reinforced Cement Concrete In open Foundation Complete As Per Drawing And Technical Specification. RCC Footing Grade M30

9.22

-

-

... More
Providing PCC M-150 in nominal mix of (1:2:4) in foundation with approved quality of store chips 20 mm-6 mm size graded and clean coarsed sand of FM 2.5 to 3.0 including screeing shuttering mixing cement concrete in mixer and placing in position vibrating striking curing taxes and royalty all complete as per building specification and directio of E/I

2712.97

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1) cement: 1.5 coarse sand(zone-III) :3 graded stone aggregate 20 mm nominal size).

6.34

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to(1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size)

9.01

-

-

... More
Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Foundation - RCC-300

33.34

-

-

... More
REINFORCEMENT

-

-

-

... More
Providing tor steel reinforcement of 10 mm dia. As per approved design and drawing excluding carriage of MS rods to work site cutting, bending, and binding with annealed wire with cost of wire removal of rust, placing the rods in position all complete as per building specification & direction of E/I.

45.8

-

-

... More
Road Cutting and Road Restoring

-

-

-

... More
Supplying tools and cutting road as well restoring the same as per specification and direction of E/I.

-

-

-

... More
Pucca Road (Except black top only taken out material to be used) for cutting road as per requirement.

2838

-

-

... More
Water bound macadam road (taken out material will be used) for cutting road as per requirement and making good the same.

14253

-

-

... More
Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15 meter lead and disposal of un-serviceable materials with all leads all complete as per direction of E/I

2678

-

-

... More
Brickwork

-

-

-

... More
Providing designation 75A brick work in CM 1:6 in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, costs of screening, materials, scaffolding, racking out joints to 15 mm depth curing, taxes and royalty all complete as per building specification & direction of E/I.

181.81

-

-

... More
Providing designation 75 A brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening, materials, scaffolding, raking out joints to 15 mm depth curing, taxes & royalty all complete as per building specification & direction of E/I.

79.84

-

-

... More
Providing designation 75A one brick flat soling joint filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I

284.81

-

-

... More
Plaster

-

-

-

... More
Providing 12 mm cement plaster (1:4) with clean coarse sand of F.M.1.5 including screening ,curing with all leads & lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.(for inside surface)

1126.03

-

-

... More
Providing 19 mm water proof cement plaster (1:3) with clean coarse sand of FM 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.(for exterior surface)

236.46

-

-

... More
Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding, taxes & royalty all complete as per building specification & direction of E/I.

57.93

-

-

... More
Providing 12 mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, Curing with all leads & lifts of water, scaffolding, taxes and royalty all complete as per building specification & direction of E/I.

1502.99

-

-

... More
Providing 12 mm. cement plaster (1:3) with clean coarse sand of F.M. 1.5 and 1.5mm cement punning including screening, curing wit taxes and royalty all complete as per building specification & direction of E/I.

264.38

-

-

... More
Dewatering

-

-

-

... More
Dewatering the excavate d trenches and pools of water in the building trenches/pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel etc Complete)

6000

-

-

... More
INTAKE

-

-

-

... More
.Providing and laying cement concrete in retaining walls, return walls, walls 1.2:4 (1 Cement: 2 coarse sand (zone-III):4 graded stone aggregate 20 mm nominal size) including attached pilasters, columns, ers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing.

9.97

-

-

... More
Providing & laying in situ cement concrete of trap/ granite/ quartzite/ gneisis metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, plywood form work, bully/steel propups, compaction, finishing and curing etc complete.(By weigh batching and mix design for M-250 and M-300 only. Use of L and T, A.C.C. Ambuja, Birla Gold, Manikgad, Rajashree, etc cement is permitted.) (excluding M.S. or Tor reinforcement.)

31.09

-

-

... More
Providing & casting in situ cement concrete of trap/ granite/ quartzite/ gneisis metal of approved quality for RCC work as per detailed drawings and designs as directed by Engineer-in-charge including normal dewatering, plywood form work, bully/steel prop-ups, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing etc complete.(By weigh batching and mix design for M-250 and M-300 only. Use of L and T, A.C.C. Ambuja, Birla Gold, Manikgad, Rajashree, etc cement is permitted.) (excluding M.S. or Tor reinforcement.)

132.28

-

-

... More
Providing structural steel work in single stanchion composed of RSJ , channel etc. with caps, bases, mild steel plates, angles, brackets, cleats, gusset plates, anchor bolts etc. as per detailed design amd drawing or as directed by Engineer-in-charge.

1.68

-

-

... More
Providing random rubble stone masonry in C.M. (1:4) in foundation and plinth with hammer dressed stone of less than 0.03 M3 in volume and clean coarse sand of F.M: 2 to 2.5 including cost of screening, raking out joints to 20 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.

1.69

-

-

... More
Providing and fixing M.S.chequerred plate flooring of following thichness supported on M.S. angles ( 25 X 25 X 5mm size) including welding cutting and fabricating the plate of required square or rounding shape, making holes in the plate, including providing and applying 3 coats of anticorrosive paint etc. complete as directed by Enginneer in-charge

8

-

-

... More
Supplying & fixing rolling shutters of approved make, made of required sixe M.S.laths interlocking together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside & outside locking with push & pull operation complete includeing cost of providing & fixing necessary 27.5 cm long wire springs grade No.2 & M.S. top cover of required thickness for rolling shutter.

6.25

-

-

... More
Supplying, fitting & fixing good quality, well dressed & well seasoned sal wood work in chaukhat in doors, windows, skylights, fan lights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls & lintels all complete as per building specification & direction of E/I.

8.1

-

-

... More
Supplying,fitting & fixing 38 mm thick good quality, well dressed & well seasoned sal wood fully paneled shutters in door & window with 25 mm, thick panels with one side plain & other side champhered with aluminium fittings such as hinges,sliding door bolts tower bolts, handles or rings, hooks & eyes cleats, sand blocks as per schedulle taxes and royalty all complete as per building specification & direction of E/I.

6.48

-

-

... More
Providing two coat of oil bound distemper of approved shade and make over old surface including washing, cleaning & preparing the walls, scaffolding, washing of floors & taxes all complete as per building specification & direction of E/I.

193.02

-

-

... More
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete.

236.46

-

-

... More
Supplying & laying ( properly as per design and drawing ) rip-rap with good quality of boulders duly packed including the cost of materials, royalty all taxes etc.but excluding the cost of carriage all complete as per specification & direction of E/I.

60

-

-

... More
Providing fixing in position M.S. ladder 0.50 M wide consisting of 75X10mm M.S. flats as stringers and 16 mm dia. M.S. bar in double rows as steps placed at 25 cm c/c including cost of material and labour involved, welding anchoring and applying three coats of anticorrosive paint etc. complete as directed by Engineer-in-charge.

17

-

-

... More
Providing & fixing in position copper lightening conductor including copper rod of 20 mm dia as per upper terminal 1.5 M long with a knob at end & with conical spike at top, copper tape conductor 20 X 3 mm size, copper earth plate of 3 mm thick & 0.81 Sqm. In area, clamps at 1 M c/c including necessary excavation, laying & fixing the conductor, providing & fixing 40 mm G.I.pipe upto 3M height from ground & 0.5 M below ground including making all connections, filling the earthing pit with charcoal, salt etc. & refilling & watering etc. complete as per specification laid down in relevent I.S. codes. - 25 mts

1

-

-

... More
Providing and fixing GI pipe railing having 1.0 M height consisting 50x50x6 mm thick MS angles as verticals at 1.5 m c/c and additional posts at every corner with 3 rows of 25 mm dia GI pipes of medium class veriety as horizontal and painting 3 coats of oil paint over one coat of anticorrosive paint at approved colour and shade including cost of all labour, transporting bends to curved shape etc. complete

34

-

-

... More
Coffer Dam

-

-

-

... More
Providing, constructing coffer dam in river basin / dam storages as per type design including excavation, filling the middle portion with B.C. soil (in gunny bags if required). Providing impervious / semipervious materials on both sides of B.C. soil (in gunny bags if required) including ramming, compacting to the satisfaction of Engineer-in-charge till the completion of work including dismantling coffer dam after completion of works and disposing off the material as directed by the Engineer-in-charge.

2750.82

-

-

... More
Approach Bridge

-

-

-

... More
Plain/Reinforced Cement Concrete In open Foundation Complete As Per Drawing And Technical Specification. RCC Column Grade M30

12.49

-

-

... More
Plain/Reinforced Cement Concrete In open Foundation Complete As Per Drawing And Technical Specification. RCC Column Grade M25 and walkway slab

18.4

-

-

... More
Providing and fixing GI pipe railing having 1.0 M height consisting 50x50x6 mm thick MS angles as verticals at 1.5 m c/c and additional posts at every corner with 3 rows of 25 mm dia GI pipes of medium class veriety as horizontal and painting 3 coats of oil paint over one coat of anticorrosive paint at approved colour and shade including cost of all labour, transporting bends to curved shape etc. complete

56

-

-

... More
Provide two coat of snowcem of approved shade & make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding, curing & taxes all complete as per building specification & direction of E/I.

197.41

-

-

... More
RWRM , CWRM

-

-

-

... More
DI Pipe: Providing and Supplying ISI mark Centrifugally cat (Spun) Ductile Iron Pipes of 100 mm and above all diameter for water works with socket & spigot ends confirming to IS 8329/ 2000 in the standard working lengths of 4.5, 5.5 & 6 m suitable for classification K-7 & K-9 suitable for push-on-joint (rubber gusket D jointing) with cement mortar lining inside the pipes with outside zinc and bittuminous coating.

-

-

-

... More
250 mm Dia K-9

2195

-

-

... More
350 mm Dia K-9

1404

-

-

... More
450 mm Dia K-9

3483

-

-

... More
Providing and supplying D.I. specials and fitting with sealing rubber gasket of SBR complete with cast iron follower gland and M.S nutbolts coated or otherwise protected from rusting and suitable for DI pipes includingcost of labour, materials, and transportation to stores/ site, loading and unloading including all taxes etc. complete as per IS-9523 class K-12.

-

-

-

... More
200 - 300 mm Dia.

2499

-

-

... More
350 - 450 mm Dia.

4583

-

-

... More
Supplying labours, tools and tackles, lubricant etc. for laying and jointing C.I.S/S tyton pipes (class LA) trenches supplying rubber gasket (Rubber gasket confirming to I.S.S.-5382-1969) and making gasket joint including providing night guard, barrier and red light to safe guard against accident, all complete (Pipe to be supplied departmentally free of cost and laying of pipes is to be done as per I.S.S. 3114-1985) as per design, specification and direction of E/I.

-

-

-

... More
250 mm Dia

2195

-

-

... More
350 mm Dia

1404

-

-

... More
450 mm Dia

3483

-

-

... More
Labour charge for one cutting of cast iron pipe and specials including supplying, necessary tools and plants, chipping or filling the surface finish as per specification and direction of E/I.

-

-

-

... More
250 mm Dia

3

-

-

... More
350 mm Dia

2

-

-

... More
450 mm Dia

2

-

-

... More
Supplying labours, tools and tackles for testing of laid CI pressure pipe upto 60m head of water all complete as per specification and direction of E/I.

-

-

-

... More
250 mm Dia

2195

-

-

... More
350 mm Dia

1404

-

-

... More
450 mm Dia

3483

-

-

... More
Supplying labour and tools for fixing C.I. sluice valve in trenches with pair of C.I. Tail piece including making laed caulked joints and flanged joint as per I.S.S. specification including supplying all jointing material (pig lead confirming to I.S.S 782-1978, yarn confirming to I.S.S. 6587-1972 and nuts and bolt confirming to I.S.S. 1364-1983) including drilling holes in flanges if required as per specification and direction of E/I.

-

-

-

... More
250 mm Dia

2

-

-

... More
350 mm Dia

3

-

-

... More
450 mm Dia

2

-

-

... More
Lowering & laying and fixing in proper alignment and position all types of CI Kinetic air valve as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all materia and giving satisfactory hydraulic testing etc. complete. ( For all class of valves ) (PN-1 & PN-1.6)

-

-

-

... More
80 mm dia

5

-

-

... More
100 mm dia

12

-

-

... More
Providing and Supplying ISI Mark CI D/F reflux valves (Non return Valves) of following dia with inspection charges, 9 unloading from railway wagon, loading into truck transportation upto departmental stores/site unloading stacking etc. complete reflux valve as per IS 5312 Part I (1984)

-

-

-

... More
250 mm dia

2

-

-

... More
350 mm dia

3

-

-

... More
450 mm dia

2

-

-

... More
Providing, supplying, Kinetic double orifice type Air valve as per MJPs standard specification combined with screw down isolating valve, small elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring, inlet face drilled including al taxes, insurance, third party inspection charges, loading, unloading, transportation to site etc. complete including cost of all materials, hudraulic testing etc .PN - 1.6 Kinetic

-

-

-

... More
80 mm dia

5

-

-

... More
100 mm dia

12

-

-

... More
Providing and Supplying ISI Mark CI D/F reflux valves (Non return Valves) of following dia with inspection charges, 9 unloading from railway wagon, loading into truck transportation upto departmental stores/site unloading stacking etc. complete reflux valve as per IS 5312 Part I (1984)

-

-

-

... More
250 mm dia

2

-

-

... More
350 mm dia

3

-

-

... More
450 mm dia

2

-

-

... More
Providing double flanged sluice valve confirming for IS 2906/14846 including worn gear arrengements as per test pressure stainless steel splindle, caps, transportation etc. all complete . ( Sluice and scour valve )

-

-

-

... More
250 mm dia

2

-

-

... More
350 mm dia

3

-

-

... More
450 mm dia

2

-

-

... More
Providing, supplying, Kinetic double orifice type Air valve as per MJPs standard specification combined with screw down isolating valve, small elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring, inlet face drilled including al taxes, insurance, third party inspection charges, loading, unloading, transportation to site etc. complete including cost of all materials, hudraulic testing etc .PN - 1.6 Kinetic

-

-

-

... More
80 mm dia

5

-

-

... More
100 mm dia

12

-

-

... More
AMR Bulk Meters Providing, installing testing and commissioning of in line battery operated ultrasonic bulk type water meters ISO 4064 with built in data logger and GSM/GPRS modem for transfer of data communication to remote central computer as per working on following conditions and specifications.the meter shall be suitable for 50° C and provided with IP 68 protection class with complete immersion of water. The meter shall have battery life of min. 10 years should be able to detect the reverse flow volumn and tampering. the accuracy of the meter shall be +/- % of measured value including 36 months guarantee etc. complete.

-

-

-

... More
250 mm dia

2

-

-

... More
350 mm dia

1

-

-

... More
450 mm dia

1

-

-

... More
Water Treatment Plant - 13.5 MLD

-

-

-

... More
Designing (aesthetically ), providing constructing and commissioning Conventional Water Treatment Plant consisting of all Civil, Mechanical and Electrical works including cost of providing and applying epoxy paint to inside surface of water retaining structures in contact with chlorine and providing antitermite treatment to entire structure below ground level, mechanical and electrical components of various sub-works as given below, including necessary hydraulic testing, structural testing, equipment testing and trial run for a period of 3 months, etc. complete as directed by Engineer-in-charge (turn-key job).

-

-

-

... More
Aeration Fountain- Plan are a not less than 0.625 square metre per MLD

-

-

-

... More
Ventury Flume - With necessary devices, consisting of simple mechanical indicator. (Pedestal type gauge)

-

-

-

... More
Flash Mixer-Rapid mixing device, detention time 60 seconds to give velocity gradient 300 to 400 sec -1, vane mixer type conforming to I.S. 7090 of 1985.

-

-

-

... More
Flocculator – Conforming to I.S.7208-1974 (Type-C) with detention period of 30 minutes.

-

-

-

... More
Clarifier - Horizontal flow circular tank, detention period 2-5 hours, overflow rate 30 cubic metre per square metre per day (to be specified), Weir loading not more than 300 cubic metre per metre per day, with mechanical sludge scraper conforming to I.S. No. 10313-1982. with necessary inlet arrangements.

-

-

-

... More
Rapid Sand Filter sand Filter House-Filter designed for filteration rate of 5,000 litres per square metre per hour, minimum 2 beds for plant upto 10 MLD, for larger plants as specified, filters to be located in filter house with roof slab, pipe gallery and platform minimum 5.5 metre in width with constant rate filtration or declining rate filtration.

-

-

-

... More
FilterSand-Effective size 0.45 to 0.70mm, uniformity coefficient not more than 1.7, nor less than 1.3, depth of water over sand 0.75M, free board 50cm, gravel 0.45M in depth, sand and gravel conforming to I.S. 8491 (i)-77, back wash by air wash, standard appurtenances (to be specified), rate of flow controller, filter gauge, sand expansion gauge, etc.

-

-

-

... More
Wash Water Tank-Capacity to be specified and suitable to supply water to wash specified number of filter beds at a time 12 minutes @ 600 lit/sqm/min. under a head of 12 m at under drain.

-

-

-

... More
Wash Water Pumps- Capacity to fill water tank in 1 hour with 100% standby.

-

-

-

... More
Air Blowers-Capable of delivering 600 LMP per square metre of free air, of filter area at 0.4kg / sq.cm at the under drains (100% stand by) for period of 5 min.

-

-

-

... More
Chemical House in Two Storeys

-

-

-

... More
Ground floor to accommodate 7 days' alum requirement and sundry storage. (Minimum 4 m height)

-

-

-

... More
First floor to accommodate alum and lime tanks. Chain pully block etc. (min. 5 m height)

-

-

-

... More
Solution tanks-Minimum 3 tanks (one for preparation, second for dosing and third as stand by), each tank capable of giving 8 hours maximum dose without interruption, minimum free board 0.30M, trays for dissolving, level indicator, mechanical agitation devices, solution feed and drain lines, solution feed device (constant head device, strength of solution upto 10% only) conforming to I.S. 9222 Part-I 1979.

-

-

-

... More
Pure Water Sump and Pump House.

-

-

-

... More
Capacity of sump – One hour of designed flow.

-

-

-

... More
Pump House- Pump house of required size over the sump or by the side.

-

-

-

... More
Store House-Suitable for alum storage of three months and 7 days temporary storage, 7 days TCL requirement in mansoon with 20% extra capacity for other sundry articles.

-

-

-

... More
Vacuum feed type Chlorinators- Make tobe approved by MJP.

-

-

-

... More
Conforming to I.S. 10533 - A Part-II 1983

-

-

-

... More
Rate for withdrawal

-

-

-

... More
Temperature Degree 'C'

-

-

-

... More
Degree "C" Cylinders

-

-

-

... More
45 67 Tonnes

-

-

-

... More
10 6.35 9.50 110

-

-

-

... More
15 10.75 16.10 130

-

-

-

... More
20 14.50 21.24 254

-

-

-

... More
27&Above 18.70 28.12 315

-

-

-

... More
Chlorinator equipment and container room to conform to I.S. 10553 Part-I 1983.

-

-

-

... More
100% standby shall be provided.

-

-

-

... More
By pass arrangements - C.I. or M.S. pipes.

-

-

-

... More
Disposal of waste from WTP : Safe disposal arrangement to nearby nalla including cost of pipe.

-

-

-

... More
For WTP of capacity 30 mld and more additional arrangement for backwash water recycle shall be provided , including sump, pumping machinary, rising main etc. complete.

-

-

-

... More
Drainage arrangements To decant all units of WTP with CI pipes upto boundary of each unit and further extension with RCC pipes to nearby nalla.

-

-

-

... More
Electrical installation – Both internal and external including entire plant area.

-

-

-

... More
Laboratory equipment –As per requirement (to be specified during tendering).

-

-

-

... More
Sanitary blocks – Carpet area -15 square metre minimum upto 25 Mld and 25 square metre above 25 Mld.

-

-

-

... More
Administrative block and internal road-To accommodate office room, chlorine room, laboratory room, panel board room, blower room etc. and WBM road to connect all units from main gate of plot.

-

-

-

... More
Rates given below are inclusive of up lift pressure if any and dewatering during entire work.

-

-

-

... More
All pipes conduits channel with 20% overloading.

-

-

-

... More
These rates are applicable for seismic zones 2, 3 and 4.

-

-

-

... More
All RCC structures shall be constructed in M-300

-

-

-

... More
Note: Conditions from Sr. No. 1 to 22 shall form a part and parcel of the tender and must be incorporated in draft tender papers of conventional treatment plants (proposed).

-

-

-

... More
Cost of 13.5 MLD Conventional Water Treatment Plant

1

-

-

... More
Cost of Minor repair for existing WTP + Minor repair for existing Pump House

1

-

-

... More
Sludge Settling Tank -3 Nos. For Existing Scheme, Under construction scheme & Proposed Scheme

-

-

-

... More
Providing and laying R.C.C. M-200 with nominal mix of (1:2:4) in foundation and plinth with approved quality of stone chips 20 mm to 6 mm size grdded and clean course sand F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, (but excluding the cost of reinforcement, taxes and royalty all complete as per building specification and direction of E/I

15.42

-

-

... More
Providing and fixing GI pipe railing having 1.0 M height consisting 50x50x6 mm thick MS angles as verticals at 1.5 m c/c and additional posts at every corner with 3 rows of 25 mm dia GI pipes of medium class veriety as horizontal and painting 3 coats of oil paint over one coat of anticorrosive paint at approved colour and shade including cost of all labour, transporting bends to curved shape etc. complete

122.4

-

-

... More
Providing & casting in situ cement concrete of trap/ granite/ quartzite/ gneisis metal of approved quality for RCC work as per detailed drawings and designs as directed by Engineer-in-charge including normal dewatering, plywood form work, bully/steel prop-ups, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing etc complete.(By weigh batching and mix design for M-250 and M-300 only. Use of L and T, A.C.C. Ambuja, Birla Gold, Manikgad, Rajashree, etc cement is permitted) (excluding M.S. or Tor reinforcement.)

79.86

-

-

... More
Providing 1.5 mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I

426

-

-

... More
Manufacturing, providing and supplying spirally welded/ ERW/ SAW/ Fabricated M.S. pipes (Commercial quality) inclunding procurement of plates, gas cutting to required size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming 'V' edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, unloading, stacking, excluding GST levied by GOI & GOM in all respect etc. complete as per IS-3589 and IS-5504 as applicable as per specification (No negative tolerance in thickness is permissible) (200mm for casing)

60

-

-

... More
Lowering laying in position to correct line and level including MS pipe with / without any out coating on pedistal or chairs upon prepared formation. The rate to include loading, unloading hoisting, marginal cutting whrerever required, assembling and tack welding, and transportation upto 500 m etc. completed as specified. (upto 250 mm Dia.), (5 mm to 8 mm thick)

150

-

-

... More
Providing, erecting and giving test of Centrifugal Monoblock pump set conforming to IS 9079 operating at 2900 RPM with CI impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type. Pump set shall be suitable for working at various discharge and head requirements. Pump shall be erected on Provided C.C. foundation block with suitable foundation bolts grouted in C.C. foundation block (2.0 HP)

6

-

-

... More
Mechanical & Electrical Work at Intake for Existing Scheme and Proposed Scheme

-

-

-

... More
Vertical Turbine Pump -: Supply and delivery of Vertical type water/Oil lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging the following duty condition as given below due to all causes with surface discharge head confirming to IS 1710 and as amended as on date with accessories as per IS 5120/1977( Reaffirmed 2011 ) and as amended thereafter to suit the site condition. The speed, No. of stages, sizes of column pipes and line shaft indicated is based on site condition prevailing during investigation. The pump should be supplied with non reversible ratchet pin housing safety clutch, suction strainer etc. The Pump Bowl assembly shall be with bronze impeller running at 1450 rpm. The pump includes suitable head shaft, suitable 1.5 metre long SS line shaft required Nos. to suit the well depth, Rubber line shaft bearing of required Nos., C.I Bearing retainer of required Nos., 100 litre HDPE Pre- lubricating tank with 20mm PVC Rigid pipe connection along with GM gate valves, Suitable ERW column pipe of each 1.5m long of required Nos. to suit the well depth, Suction bell mouth of suitable size, M.S. clamps suitable for column pipe/line shaft -2 set and Spanner - 1 set etc complete-

-

-

-

... More
For proposed scheme 70HP -VT-Discharge- 542781 LPH and Head- 21 m (1W+1S)

2

-

-

... More
For existing scheme - 50HP VT,Discharge- 269645 LPH and Head- 26 m (1W+1S)

2

-

-

... More
Induction Motor -: Supply and delivery of vertical Hollow/Solid shaft Squirrel cage induction motor (IS 325 ) suitable for the above pump continuous rated TEFC/SPDP type with Class 'F' insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%) running with a speed of pump noted ab e and with inbuilt thrust bearing assembly capable of taking up the entire load and non - reverse ratchet assembly etc., complete. The motor rating noted above is the minimum and shall be such that it should never be over loaded when the pump works at MWL condition and shall be 10% over and above the maximum HP absorbed by the pump. The motor offered should be energy efficient to have maximum efficiency at high power factor. Separate thrust bearing assembly could also be supplied to take up the down load. -

-

-

-

... More
for Proposed scheme - For 60 HP

2

-

-

... More
for Existing scheme - For 40 HP

2

-

-

... More
Motor Control Panel: Supplying, installation, testing & commissioning of Floor mounted cubical LT Motor Control Panel board fabricated with MS sheet of suitable guage and size, dust and vermin proof consisting of proper power distribution 4 pole 200A copper busbar, 1 no. incoming feeder with spare of 200A MCCB, 2 nos. outgoing feeder of 160A MCCB for pumps sets, 1 no. 160A MCCB outgoing Spare feeder, 2 no. 32A & 2 no. 63A MCB feeder for lighting, other electrical utilities and spare, ELCB/RCCB, switch disconnected isolator (TPN), selector switches, Volt-meters, Ampere-meters, indicator lamps etc. all complete with internal wiring, protection units/relays, control cables and capacitor banks of proper KVAR for Power Factor control. Panel board shall be duly painted with two coats of super enameled paint of approved colour with one coat of red oxide primer according to Indian standards and instruction of E/I, etc. all complete. -- for Proposed Scheme

1

-

-

... More
Motor Control Panel: Supplying, installation, testing & commissioning of Floor mounted cubical LT Motor Control Panel board fabricated with MS sheet of suitable guage and size, dust and vermin proof consisting of proper power distribution 4 pole 200A copper busbar, 1 no. incoming feeder with spare of 200A MCCB, 2 nos. outgoing feeder of 100A MCCB for pumps sets, 1 no. 100A MCCB outgoing Spare feeder, 2 no. 32A & 2 no. 63A MCB feeder for lighting, other electrical utilities and spare, ELCB/RCCB, switch disconnected isolator (TPN), selector switches, Volt-meters, Ampere-meters, indicator lamps etc. all complete with internal wiring, protection units/relays, control cables and capacitor banks of proper KVAR for Power Factor control. Panel board shall be duly painted with two coats of super enameled paint of approved colour with one coat of red oxide primer according to Indian standards and instruction of E/I, etc. all complete. -- For Existing Scheme

1

-

-

... More
Starter: Supplying Fully automatic star delta starter to operate induction motor working on 415v,3phase,50 hz with no volt coil, Over load element, ON-OFF push buttons, with necessary materials and connected to supply, etc complete starter with original sheet steel encloser

4

-

-

... More
Earthing: Earthing with copper earth plate including accessories and providing masanory enclosure with cover plate having locking arrangement and watering pipe of 2.7 m long etc. with charcoal / coke and salt, with connection with suitable strip/wire as required conforming IS:3043.

4

-

-

... More
Crane: Providing, erecting triple spur gear type Chain Pulley Block suitable for 3 Tonne capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per IS 3832 carrying ISI mark with travelling trolley.

2

-

-

... More
Servo Controlled Automatic Voltage Stabilizer: Providing, erecting Servo Controlled Automatic Voltage Estabiliser suitable for out put voltage of 415 Volt +/-1%, 3 Ph, 50 with copper wound transformer (airfoil cooled) as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with Phidirectional wheels for easy handling, necessary monitors and user's controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and output lage, Auto/Manual selector switch, Raise/Low push buttons etc. Suitable capacity termination strips and bus bars for incomin and out going cable should be provided. All three phases shall be independently monitored and corrected Following protestions and indications shall be incorporated Over oltage Under Voltage HAND Single Phasing Cut off contacter with electronic output sensingtunit

2

-

-

... More
Cable: Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

350

-

-

... More
Cable: Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

100

-

-

... More
Transformer: Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 100 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 ℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR- NSL. For existing scheme - 100 KVA (11/.433 KV)

1

-

-

... More
Transformer: Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 ℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR- NSL. For proposed scheme - 200 KVA (11/.433 KV)

1

-

-

... More
HT Line: Cost for drawing 11 KV HT Overhead Electric line from the nearest available JBVNL existing line to Proposed substation near Pump house on PSC poles including insulators, cross arms, conductor, MS clamps & brackets, coil earthing, stay sets, gaurding channels, pcc foundations, labour & technicians, etc. all complete as per JBVNL norms & IE rules from Jharkhand state electricity board. (work shall be executed as per the sanctioned estimate of JBVNL)

10

-

-

... More
Power Conection: Cost of taking Power connection with metering & service cable from Jharkhand state electricity board, etc. all complete. (work shall be executed as per the sanctioned estimate of JBVNL)

2

-

-

... More
Lighting: Providing internal and external lighting by doing wiring and installing lumenaries e.g. suitable Wattage of LED light fittings in pump house, gangway, etc. all complete as per requirement.

2

-

-

... More
Safety Items: Supplying, Installation and erecting of Fire extinguisher, Lightening Arrestor, emergency light, First aid box, insulation gloves & shoes, tools & tackles, rubber matting, instruction manual, etc. as per requirement and Indian standards at Pump house.

2

-

-

... More
Mechanical & Electrical Work at WTP for Existing Scheme and Proposed Scheme

-

-

-

... More
Centrifugal Pump -: Supply and delivery of Horizontal split casing centrifugal pump conforming to IS 1520 and as amended thereafter with CI casing and split glands, stainless steel shaft, hydraulically and dynamically balanced bronze impellers capable of discharging required quantity of water against a total head noted below due to all causes and with the accessories such as G.M air release cock, Grease cup, G.I priming funnel, M.S lifting hook, drip water G.I pipe connections, leading to the outside of pump house rubber water deflector, double flap foot valve, G.M strainer including unique tyre type coupling, common M.S fabricated base to mount pump and motor and other standard fittings etc complete. Pump shall be capable of discharging the specified quantity at the head noted at the minimum NPSH at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase, 415 V, 50 Hz, 1500 RPM.

-

-

-

... More
For Existing Scheme -: 40HP CF-Discharge- 167542 LPH and Head- 30 m (1W+1S)

2

-

-

... More
For Existing Scheme -: Discharge- 40HP CF-Discharge- 102102 LPH and Head- 52 m (1W+1S)

2

-

-

... More
For proposed scheme - 100HP-CF- Discharge- 281396 LPH and Head- 65 m (2W+1S)

3

-

-

... More
Induction Motor -: Supply and delivery of AC three Phase 4 pole Horizontal squirrel cage Induction motor confiriming to IS 325/1996 and as amended thereafter with Class F insulation to suit the speed of pump and suitable for operation with continous S1 rated, 415 V +/- 10 %, 50 HZ +/- 5%, TEFC (upto 20 HP), SPDP (above 20 HP). The motor offered should be of energy efficient motors.

-

-

-

... More
For Existing Scheme - 40 HP

4

-

-

... More
For proposed scheme - 100 HP

3

-

-

... More
Motor Control Panel: Supplying, installation, testing & commissioning of Floor mounted cubical LT Motor Control Panel board fabricated with MS sheet of suitable guage and size, dust and vermin proof consisting of proper power distribution 4 pole 500A copper busbar, 1 no. incoming feeder with spare of 500A MCCB, 6 nos. outgoing feeder including spare feeder of 100A MCCB for pumps sets, 2 nos. 32A MCB & 2 nos. 100A MCCB feeder for lighting, other electrical utilities and spare, ELCB/RCCB, switch disconnected isolator (TPN), selector switches, Volt-meters, Ampere-meters, indicator lamps etc. all complete with internal wiring, protection units/relays, control cables and capacitor banks of proper KVAR for Power Factor control. Panel board shall be duly painted with two coats of super enameled paint of approved colour with one coat of red oxide primer according to Indian standards and instruction of E/I, etc. all complete. - For Existing Scheme

1

-

-

... More
Motor Control Panel: Supplying, installation, testing & commissioning of Floor mounted cubical LT Motor Control Panel board fabricated with MS sheet of suitable guage and size, dust and vermin proof consisting of proper power distribution 4 pole 800A copper busbar, 1 no. incoming feeder with spare of 800A MCCB, 4 nos. outgoing feeder including spare feeder of 250A MCCB for pumps sets, 3 nos. outgoing feeder including spare feeder of 63A MCCB for pumps sets, 2 nos. 32A MCB & 2 nos. 100A MCCB feeder for lighting, other electrical utilities and spare, ELCB/RCCB, switch disconnected isolator (TPN), selector switches, Volt-meters, Ampere-meters, indicator lamps etc. all complete with internal wiring, protection units/relays, control cables and capacitor banks of proper KVAR for Power Factor control. Panel board shall be duly painted with two coats of super enameled paint of approved colour with one coat of red oxide primer according to Indian standards and instruction of E/I, etc. all complete. For Proposed Scheme

1

-

-

... More
Starter: Supplying, installation, testing & commissioning of assembled Fully Automatic Star Delta starter, in a provided cubical panel to operate induction motor with no volt coil, over load relay and ON/OFF push buttons, with necessary material and connected to supply, etc. all complete.

-

-

-

... More
For Existing Scheme - 40 HP Motors

4

-

-

... More
For proposed scheme - 100 HP Motors

8

-

-

... More
Earthing: Earthing with copper earth plate including accessories and providing masanory enclosure with cover plate having locking arrangement and watering pipe of 2.7 m long etc. with charcoal / coke and salt, with connection with suitable strip/wire as required conforming IS:3043.

7

-

-

... More
Crane: Providing, erecting triple spur gear type Chain Pulley Block suitable for 3 Tonne capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per IS 3832 carrying ISI mark with travelling trolley.

2

-

-

... More
Servo Controlled Automatic Voltage Stabilizer: Supplying, installation, testing & commissioning of 150 KVA Servo Controlled Automatic Voltage stabiliser suitable for out put voltage of 415 Volt +/-1%,3 Ph, 50 Hz, with copper wound transformer (oil cooled). The stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and user's controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Low push buttons etc. Protections and indications shall be incorporated with Over Voltage / Under Voltage, Single Phasing & Cut off contactor with electronic output sensing unit, including T-oil, change over switch, earthing, etc. all complete. For Existing Scheme

1

-

-

... More
Servo Controlled Automatic Voltage Stabilizer: Supplying, installation, testing & commissioning of 150 KVA Servo Controlled Automatic Voltage stabiliser suitable for out put voltage of 415 Volt +/-1%,3 Ph, 50 Hz, with copper wound transformer (oil cooled). The stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and user's controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Low push buttons etc. Protections and indications shall be incorporated with Over Voltage / Under Voltage, Single Phasing & Cut off contactor with electronic output sensing unit, including T-oil, change over switch, earthing, etc. all complete. For Existing Scheme

1

-

-

... More
Servo Controlled Automatic Voltage Stabilizer: Providing, erecting Servo Controlled Automatic Voltage Estabiliser suitable for out put voltage of 415 Volt +/-1%, 3 Ph, 50 with copper wound transformer (airfoil cooled) as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with Phidirectional wheels for easy handling, necessary monitors and user's controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and output lage, Auto/Manual selector switch, Raise/Low push buttons etc. Suitable capacity termination strips and bus bars for incomin and out going cable should be provided. All three phases shall be independently monitored and corrected Following protestions and indications shall be incorporated Over oltage Under Voltage HAND Single Phasing Cut off contacter with electronic output sensingtunit For Proposed Scheme

1

-

-

... More
Cable: Power wiring with required 240 Sq mm, 3.5 core, 1.1KV grade, armoured cable, Standard Aluminium conductor, XLPE/PVC insulated cable from Transformer to Stablizer & Panel (MCP) including laying on wall or on floor as where required, jointing and making proper terminations, etc. all complete.

300

-

-

... More
Cable: Power wiring with 25 Sq mm, 3 core, 1.1KV grade, unarmoured cable, Standard Copper conductor, XLPE/PVC insulated cable from Panel (MCP) to Motors & Staters including laying on wall or on floor as where required, jointing and making proper terminations,etc. all complete.

100

-

-

... More
Cable: Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL - 70 Sq mm

80

-

-

... More
Transformer: Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 ℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR- NSL. For Existing Scheme - 200 KVA (11/.433 KV)

1

-

-

... More
Transformer: Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 500 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 ℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR- NSL - For Proposed Scheme

1

-

-

... More
HT Line: Cost for drawing 11 KV HT Overhead Electric line from the nearest available JBVNL existing line to Proposed substation near Pump house on PSC poles including insulators, cross arms, conductor, MS clamps & brackets, coil earthing, stay sets, gaurding channels, pcc foundations, labour & technicians, etc. all complete as per JBVNL norms & IE rules from Jharkhand state electricity board.

11

-

-

... More
Power Connection: Cost of taking Power connection with metering & service cable from Jharkhand state electricity board, etc. all complete.

2

-

-

... More
Safety Items: Supplying, Installation and erecting of Fire extinguisher, Lightening Arrestor, emergency light, First aid box, insulation gloves & shoes, tools & tackles, instruction manual, etc. as per requirement and Indian standards at Pump house.

2

-

-

... More
ESR ( Elevated Service Resevoir)

-

-

-

... More
Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 metres centre to centre for ESR having capacity upto 500 cum and not more than 6 m c/c for ESRs having capacity above 500 Cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling disposing off the surplus stuff within a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout,overflow and bypass arrangements as per departmental design, providing and fixing accessories such as M.S. ladder, C.I. manhole frame and covers, water level indicators, lightening conductor, G.I. pipe railing around walk way and top slab, providing spiral stair case from ground level to roof level, M.S. grill gate of 2 M height with locking arrangement of approved design, B.B.masonry chambers for all valves, ventilating shafts, providing and applying three coats of cement paint tothe structure including roof slab, epoxy painting to internal surface and antitermite treatment for underground parts of the structure and giving satisfactory water tightness test as per I.S. code. The job to include painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in-Charge.

-

-

-

... More
The design of the structure be in accordance with relevant I.S. specification (I.S. 3370 - 1965 or revised.)

-

-

-

... More
The design shall satisfy the stipulations as per I.S. 1893 - 1984 and I.S. 13920 / 1993 for seismic force and I.S. - 11682 / 1985 for R.C.C. staging of overhead tanks.

-

-

-

... More
For design having more than 6 columns, provision of internal bracing is obligatory. External bracings is also obligatory.

-

-

-

... More
Plain round mild steel bars grade-I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall be used, grade-II mild steel bars will not be allowed.

-

-

-

... More
These rates include providing M.S. ladder for E.S.R.s upto 2 lakh litres capacity and providing spiral staircase for E.S.R. above 2 lakh litres capacity

-

-

-

... More
Staging shall have to be designed with stresses of M-200 concrete for ESR. However all RCC construction should be done in M-300

-

-

-

... More
These rates are including the cost of uplift pressure if any and entire dewatering during execution. In case of water logging area where water is stretch at shallow depth, extra provision of dewatering shall be made as per site condition.

-

-

-

... More
All conditions given in the Member Secretary's Circular No. MJP / TS-I / 350 / 1668 dt. 2-8-97 and MJP / S-I / 350 / 2127 dt. 13-7-99 shall be strictly followed and additional cost, if any, due to these conditions is included in the rates mentioned below.

-

-

-

... More
75% part rate shall be payable for reinforcement concrete and plastering items of containers of E.S.R. till satisfactory hydraulic testing for water tightness is given; and till that work shall be treated as incomplete.

-

-

-

... More
The rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet, washout, overflow and bypass arrangement. The scope of work, however, includes cost of erecting, laying and jointing of pipes and valves including cost of jointing materials upto 5 M beyond outer face of outermost column

-

-

-

... More
For ESR upto 500 cum capacity C.I. double flanged pipes upto 300 mm dia shall be provided and C.I. specials shall be used. For ESR above 500 cum capacity C.I./M.S. pipe assembly with minimum 8 mm thickness upto 500 mm dia and minimum 10 mm thickness above 500 mm dia can be used with proper anti-corrosive epoxy treatment from inside and outside.

-

-

-

... More
Below mentioned rates are for foundations with individual footing with bearing capacity of 20 tonnes per square metre. For raft foundations, these rates shall be increased by 7.5% where safe bearing capacity (SBC) is 5 MT per sqm and by 5% where SBC is more than 5 MT/sqm and upto 10 MT/sqm. This % of 5% or 7.5% is applicable for estimation of amount of lumpsum item of ESR. For extra item due to change from individual foundation to raft, actual increase in concrete and steel be paid as per relevant DSR item.

-

-

-

... More
1. ESR - 2330 KL , Staging - 13 m

1

-

-

... More
2. ESR - 2200 KL , Staging - 22 m

1

-

-

... More
Auxiliary item for ESRs

-

-

-

... More
Providing and supplying ISI mark C.I. DF pipes excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to stores, unloading etc.complete as directed by Engineer-in-charge.

-

-

-

... More
250 mm dia. (For Inlate)

32

-

-

... More
350 mm dia. (For Inlate)

23

-

-

... More
100 mm dia for Washout

47

-

-

... More
250 mm dia for Overflow

32

-

-

... More
350 mm dia for Overflow

23

-

-

... More
400 mm dia.Outlet 1

28

-

-

... More
450 mm dia.Outlet 1

19

-

-

... More
Providing and supplying ISI standard CI flanged / S&S special including all taxes(central and local) railway freight,insurance,unloading from railway wagan, loading into truck transport to departmental store/site unloading stacking etc. complete

-

-

-

... More
350mm to 600 mm

500

-

-

... More
Providing double flange sluice valve confirming for IS-2906/14846 including worn gear arrengements as per test pressure stainless steel spindle, caps including all taxes transportation complete-

-

-

-

... More
250 mm dia

2

-

-

... More
350 mm dia

1

-

-

... More
AMR Bulk Meters - Providing, installing testing and commissioning of in line battery operated ultrasonic bulk type water meters ISO 4064 with built in data logger and GSM/GPRS modem for transfer of data communication to remote central computer as per working on following conditions and specifications. the meter shall be suitable for 50° C and provided with IP 68 protection class with complete immersion of water. The meter shall have battery life of min. 10 years should be able to detect the reverse flow volumn and tampering. the accuracy of the meter shall be +/- 1% of measured value including 36 months guarantee etc. complete. (With simcard and its charges, valid for 36 months)

-

-

-

... More
350 mm dia

2

-

-

... More
450 mm dia

1

-

-

... More
Repairing of ESR

-

-

-

... More
Repairy for Existing ESR including Colouring, Water proofing and minor works. Ex. ESR at WTP Campus for Zone-3 of 11,36,000 lit capacity . Staging Ht=18 M .

1

-

-

... More
Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1,5 with Integral water proofing compound Liquid @125 ml per bag cement including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/L. Brand-Sika-Plastocrate plus, MYK proof WP 10, Fosroc-Conplast X4211C, Dr. fixit Pidiproof LW+ or Equivalent,

628.4

-

-

... More
DISTRIBUTION SYSTEM

-

-

-

... More
DI Pipe: Providing and Supplying ISI mark Centrifugally cat (Spun) Ductile Iron Pipes of 100 mm and above all diameter for water works with socket & spigot ends confirming to IS 8329/ 2000 in the standard working lengths of 4.5, 5.5 & 6 m suitable for classification K-7 & K-9 suitable for push-on-joint (rubber gusket D jointing) with cement mortar lining inside the pipes with outside zinc and bittuminous coating.

-

-

-

... More
100mm dia. DI K-7

68768

-

-

... More
150mm dia. DI K-7

8250

-

-

... More
200mm dia. DI K-7

5211

-

-

... More
250mm dia DI K-7

2066

-

-

... More
300mm dia. DI K-7

1232

-

-

... More
350mm dia DI K-7

4367

-

-

... More
400mm dia DI K-7

1449

-

-

... More
450mm dia DI K-7

1692

-

-

... More
500mm dia DI K-7

84

-

-

... More
Providing and Supplying of ISI standard DI specials & fitting with sealing rubber gasket of SBR, complete with cast Iron follower gland & MS nut bolts coated or otherwise protected from rusting and suitable for DI pipescomplete as per IS-9523 class K-12. Note: The Rates are F.O.R at worksite in Jharkhand inclusive of Royalty, inspection Charges & other taxes but exclusive of GST & C.P.

-

-

-

... More
100 - 150 mm Dia.

77018.13

-

-

... More
200 - 300 mm Dia.

8509.35

-

-

... More
350 - 500 mm Dia.

7591.68

-

-

... More
Supplying labours, tools and tackles, lubricant etc. for laying and jointing C.I.S/S tyton pipes (class LA) trenches supplying rubber gasket (Rubber gasket confirming to I.S.S.-5382-1969) and making gasket joint including providing night guard, barrier and red light to safe guard against accident, all complete (Pipe to be supplied departmentally free of cost and laying of pipes is to be done as per I.S.S. 3114-1985) as per design, specification and direction of E/I. (without gasket)

-

-

-

... More
100mm dia. DI K-7

68768

-

-

... More
150mm dia. DI K-7

8250

-

-

... More
200mm dia. DI K-7

5211

-

-

... More
250mm dia DI K-7

2066

-

-

... More
300mm dia. DI K-7

1232

-

-

... More
350mm dia DI K-7

4367

-

-

... More
400mm dia DI K-7

1449

-

-

... More
450mm dia DI K-7

1692

-

-

... More
500mm dia DI K-7

84

-

-

... More
Supplying labours, tools and tackles for testing of laid CI or U.P.V.C. or H.D.P.E. or A.C. pressure pipe upto 60m head of water all complete as per specification and direction of E/I.

-

-

-

... More
100mm dia. DI K-7

68768

-

-

... More
150mm dia. DI K-7

8250

-

-

... More
200mm dia. DI K-7

5211

-

-

... More
250mm dia DI K-7

2066

-

-

... More
300mm dia. DI K-7

1232

-

-

... More
350mm dia DI K-7

4367

-

-

... More
400mm dia DI K-7

1449

-

-

... More
450mm dia DI K-7

1692

-

-

... More
500mm dia DI K-7

84

-

-

... More
Supplying labour and tools for fixing C.I. sluice valve in trenches with pair of C.I. Tail piece including making laed caulked joints and flanged joint as per I.S.S. specification including supplying all jointing material (pig lead confirming to I.S.S 782-1978, yarn confirming to I.S.S. 6587-1972 and nuts and bolt confirming to I.S.S. 1364-1983) including drilling holes in flanges if required as per specification and direction of E/I.

-

-

-

... More
100mm dia

56

-

-

... More
150mm dia

22

-

-

... More
200mm dia

9

-

-

... More
250mm dia

11

-

-

... More
300mm dia

3

-

-

... More
350mm dia

3

-

-

... More
400mm dia

3

-

-

... More
450mm dia

8

-

-

... More
Providing double flange sluice valve confirming for IS-2906 / 14846 including worn gear arrengements as per test pressure stainless steel spindle, caps including all taxes transportation complete. (Sluice and scour valve ) Without byepass arrengement PN-1.6 with ED

-

-

-

... More
100mm dia

56

-

-

... More
150mm dia

22

-

-

... More
200mm dia

9

-

-

... More
250mm dia

11

-

-

... More
300mm dia

3

-

-

... More
350mm dia

3

-

-

... More
400mm dia

3

-

-

... More
450mm dia

8

-

-

... More
AMR Bulk Meters : Providing, installing testing and commissioning of in line battery operated ultrasonic bulk type water meters ISO 4064 with built in data logger and GSM/GPRS modem for transfer of data communication to remote central computer as per working on following conditions and specifications. the meter shall be suitable for 50° C and provided with IP 68 protection class with complete immersion of water. The meter shall have battery life of min. 10 years should be able to detect the reverse flow volumn and tampering. the accuracy of the meter shall be +/- 1% of measured value including 36 months guarantee etc. complete. (With simcard and its charges, valid for 36 months)

-

-

-

... More
200 mm dia

2

-

-

... More
250 mm dia

4

-

-

... More
300 mm dia

2

-

-

... More
350 mm dia

4

-

-

... More
400mm dia

2

-

-

... More
450mm dia

6

-

-

... More
Supplying transporting, the S.P. fire hydrants including duck foot bend, S.V. and S.V. road box, painting the hydrant,fixing the saddle piece, supplying, and laying required length of C.I. pipeline and jointing the same spun yarn, molten lead including caulking, fixing the S.V. road box in one brick masonary chamber in 1:5 C.M. with 12 mm thick 1:3 cement plaster both inside and outside on 1:3:6: C.C.150 mm thick etc, complete specified and directed. [As per I.S.900/1965 Revised]

18

-

-

... More
VALVE CHAMBER

-

-

-

... More
Providing and constructing B.B. masonary valve chamber with 15cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B masonery in CM 1:6 proportion precast RCC frame & cover, etc. complete as per directed by Engineer-in-charge.Wall thickness : 0.25 M for depth of 1.20M and 0.35 M for balance depth exceeding 1.20 M 1.20 X0. 90m, depth 1.5M with cover.

160

-

-

... More
Thrust Block

-

-

-

... More
Providing P.C.C. M-150 with nominal mix of (1:3:6) in foundation with approved quality stone metal ( 20 mm to 6 mm Size ) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of Engineer -in charge.

-

-

-

... More
for - 250 mm dia

23

-

-

... More
for - 350 mm dia

6

-

-

... More
for - 450 mm dia

11

-

-

... More
House Service Connection

-

-

-

... More
Providing and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour , UPVC/MDPE Pipe of required length with or without Road crossing as described below, including cost of specials like Saddle/Clamp Saddle of suitable material, and diameter suitable for Distribution main, 15mm /20mm/ 25mm respective Dia Heavy duty Brass/Polyprophylyne(Twin Jacketed ) Ferrule , Male and Female thread adapter Elbow, Bends,couplers ,Tees, Clamps of suitable material and sundry materials as per requirment, including providing and fixing medium duty 15.mm brass bib tap, GI casing pipe of suitable diameter of 32mm/ 40mm/ 50mm respectively of required length for Road crossing, including requird labour for excavation in all types of strata up to the depth of 0.75m or as per site requirement,all types of plumbing fittings, refilling , Closing the water supply in that area, dewatering, hydraulic testing and restarting the water supply ,transportation of material etc. complete as directed by Engineer in charge.

-

-

-

... More
A) Household Connection without water meter (Compression Saddle+ISI Mark Ferrul) for HDPE & PVC pipe

-

-

-

... More
For MDPE/UPVC Pipe Service Connection on Disribution main

-

-

-

... More
(With Road Crossing) For 15 mm Service connection

3852

-

-

... More
I S I mark as per IS 779/1994 Providing, installing and giving satisfactorily field testing of domestic water meter, horizontal inferential type multijet type with magnetic drive and dry dial suitable for 50 degree temperature duly sealed against tampering complete with couplings at both ends and conforming to class B as per IS 779/1994 (VI revision) with ISI mark along with manufacturer's test certificates and guarantee certificates including cost of all labour and materials. 15 mm dia

3852

-

-

... More
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box. Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the TWAD Board Officers.

3852

-

-

... More
Compond Wall - For WTP , ESR1 - 359 m ,

-

-

-

... More
Providing 25 mm thick damp proof course with cement concrete M - 150 with norminal mix of (1:2:4) with approved quality of stone chips of 20 mm to 6 mm size graded and clean coarse sand of F M 2.5 to 3 including screening , shuttering , and mixing cement concrete in mixer with 5% cico or any other approved water proffing compound and placing in position striking , curing , taxes and royalty all complete , as per building specification and direction of E/I.

89.75

-

-

... More
Providing designation 75 A brick work in CM (1:4) in super structure with approved quality of clean coarse sand of FM 2 to 2.5 including, providing 10mm thick mortar joints cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.

134.95

-

-

... More
.Providing and laying cement concrete in retaining walls, return walls, walls 1.2:4 (1 Cement: 2 coarse sand (zone-III):4 graded stone aggregate 20 mm nominal size) including attached pilasters, columns, ers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing.

6.75

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering,shuttering, finishing and reinforcement: 1:1.5:3 (1 cement: 1.5 coarse sand(zone-lu): 3 graded stone aggregate 20mm nominal size)

3.72

-

-

... More
Supplying fitting & Fixing 20 Gauge G.C.I. sheet gate fitted on M.S. angle frame of size 60x60x6 mm including cost of fabrication,providing necessary locking arrangement with haskal and domny duly fixed in P.C.C (1:2:4) blocks of required size, applying a priming red lead paint over steel work , taxes all complete as per direction of E/I.

50.26

-

-

... More
Cost of 50 x 50 x 6 mm M.S. Angle including all taxes and royalty and carriage as per specification and direction of E/I. 40 nos x 1.0m = 40.00m @4.50kg/m Total = 180 kg (10+5)%

1.29

-

-

... More
Cost of Barbed wire of 4 point 2 ply 12 SWG ,150 mm apart.

131.86

-

-

... More
Labour for cutting of M.S Angle iron post to required length one end splitted as fishtailed in a length of 150 mm complete as per building specification and direction of E/I .

71.8

-

-

... More
Drilling 6 mm holes M.S angle iron for fixing of staples etc. as per building specification and direction of E/I .

287.2

-

-

... More
Supplying fitting & Fixing straining bolt with nut size 25 cm x 10 mm dia tighten the barbed wire corner post complete as per building specification and direction of E/I.

287.2

-

-

... More
Labour for fitting and fixing barbed wire fencing in four rows horizontal up to height of 1.25 M and two diagonals including fixing of post in cement concrete at 2.5 M . Centers including cost of staples (but excluding the cost of cement concrete angle iron post its cutting and making holes ,nut and bolts )all complete as per building specification and direction of E/I .

346.44

-

-

... More
Colour washing two coats over a coat of white wash over new surface with approved quality of lime including cost of cleaning surface thoroughly and removing the scales of smoke & mosh marks with jhama, rubbing, scaffolding, washing of floors and taxes all complete as per building specification & direction of E/I. Qnty. Same as Item no.8.

1396.15

-

-

... More
Demolition Of Single Storey Building

-

-

-

... More
RCC WORK-Dismantling RCCC. work

127.17

-

-

... More
Dismantling pucca brick or lime work including stacking serviceable ma- terials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of EI. BB MASNORY

61.34

-

-

... More
STAFF QUARTER

-

-

-

... More
Providing P.C.C. M -100 with nominal mix of (1:3:6) in foundation with approved quality of stone metal grade- III (50 mm to 25 mm size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer & placing in position, vibrating, striking, curing, taxes & royalty all complete as per building specification & direction of Engineer-in-charge.

20.3

-

-

... More
Providing and laying Damp Proof Course 50 mm thik with cement concrete 1:2:4 ( 1 cement : 2 coarse sand ( zone III ) : 4 graded stone aggregate 20 mm nominal size ).

106.65

-

-

... More
Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) :3 graded stone aggregate 20 mm nominal size).

5.42

-

-

... More
Supplying, fitting & fixing good quality, well dressed & well seasoned sal wood work in chaukhat in doors, windows, skylights, fanlights and C/W celestial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls & lintels all complete as per building specification & direction of the E/I

0.63

-

-

... More
Supplying fitting and fixing 250 x 20 x 6 mm L-type M.S. Clamp properly fish tailed, including making holes and setting the same in 375 x 125 x75 mm cement concrete block (1:2:4) with cost of all labour and materials and taxes as per building specification and direction of E/I

92

-

-

... More
Supplying fitting & fixing 38 mm thick good quality well dressed and well seasoned Sal wood battened shutter ledged & braced in doors and windows with oxidized iron fitting such as hinges, sliding door bolts, tower bolts, handles or rings, hooks and eyes, cleats, sand block as per schedule, taxes & royalty all complete as per building specification & direction of Engineer–in-Charge

31.59

-

-

... More
Supplying, fitting & fixing M.S. Grill made of 20 x 6 mm M.S. Flat as per approved design & drawing properly fabricated with Joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per the building specification and direction of E/I.

482.4

-

-

... More
Providing 25 mm thick precast R.C.C. M-200 with nominal mix of (1:1.5:3) jali with approved quality of stone chips of 6 mm nominal size and clean coarse sand of FM 2.5 to 3 with 1.6 mm thick M.S. wire as per approved design and drawing and placing the same in position true to plumb and level and properly grouted with cement mortar (1:3) including cost of curing, scaffolding and finishing all complete as per building specification and direction of E/I.

1.08

-

-

... More
Providing and fixing fan hook of 16 mm dia M.S. bar 1 meter long bent to required size and shape, placed in position and fixing in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I.

6

-

-

... More
Supplying, fitting and fixing M.S.grill gate with M.S. grills made of 20 x 6 mm M.S. flats or 16 mm .M.S. square bars fitted on 25x25x6mm. M.S.Angle frame of size 60 x 60 x 6 mm. including cost offabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. (when steel is not supplied by the Deptt.) @ 63 Kg/Sqm

277.83

-

-

... More
Providing average 115mm. thick lime terracing (24 lime :36 surkhi:100 brick khoa) well beaten and compacted including maintaining proper level & slope, making ghundi with finishing treatment, cost of carriage,curing, royalty & taxes all complete as per building specification & direction of E/I.

67.4

-

-

... More
Providing average 150 mm thick dry rammed khoa beaten to 112 mm. (compacted with water) made of well burnt or jhama bricks including ramming properly till compacted thickness is achieved, curing & carriage of water with all leads, making proper slope & blending the top with cement mortar (1:10) all complete as per building specification & direction of E/I. Polished Kotah

56.68

-

-

... More
Providing 25 mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layer 19 mm thick (1:2:4) with 12 mm to 6 mm size graded stone chips and top layer 6 mm thick (1:2) with 6 mm down stone chips, in panels including cost of curing , finishing the surface smooth by rubbing with carborandum stone, taxes & royalty with all complete as per building specification & direction of E/I. Rough Shahabad

28.39

-

-

... More
White washing three coats over new surface with approved quality of lime including cost of cleaning surface thoroughly and removing the scales of smoke and mosh marks with jhama rubbing, scaffolding, washing, of floors and taxes all complete as per building specification and direction of E/I.

53.06

-

-

... More
Colour washing two coats over a coat of white wash over new surface with approved quality of lime including cost of cleaning surface thoroughly and removing the scales of smoke & mosh marks with jhama rubbing, scaffolding, washing, of floor and taxes all complete as per building specification and direction of E/I.

101.16

-

-

... More
Providing two coats of painting with ready mixed paint over a coat of primer of approved shade and make over new wooden surface includ n g preparing the surface after cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes all complete as per building specification & direction of E/I.

84.18

-

-

... More
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales, smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (mode of measurement area shall be multiplied by the coefficient as indicated in building specification).

8.82

-

-

... More
Providing two coats of painting with ready mixed paint of approved shade & make over steel surface including cleaning the surface thoroughly, scaffolding & taxes all complete as per building specification & direction of E/I.

264.38

-

-

... More
Electrification in Staff Quarter

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

9

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.

-

-

-

... More
a) 2x2.5 sq mm + l x 2.5 sq mm earth wire (M.C.B. to board)

20

-

-

... More
b) 2x4.0 sq mm + l x 4 sq mm earth wire ( main to M.C.B. to light)

10

-

-

... More
c) 2x6.0 sq mm + l x 6 sq mm earth wire (main to M.C.B. to power)

3

-

-

... More
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.

1

-

-

... More
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections. painting etc. as required.

1

-

-

... More
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc as required. 40 A

3

-

-

... More
Supplying and fixing brass batten/ angle holder including connection etc.as reqd.

8

-

-

... More
S/F 3 pin 5 Amp. Ceiling rose on the existing junction box /wooden block including connection as per reqd.

1

-

-

... More
S/F following piano type switch/socket on the existing switch box cover including connection etc as per reqd. 5/6 amps switch

1

-

-

... More
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.

-

-

-

... More
75 mm X 75 mm X 60 mm deep

8

-

-

... More
100 mm X 100 mm X 60 mm deep

2

-

-

... More
150 mm X 75 mm X 60 mm deep

2

-

-

... More
150 mm X 150 mm X 60 mm deep

3

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
a) 40 Amps

1

-

-

... More
b) 63 Amps

1

-

-

... More
Septic Tank and soak pit in staff quarter

-

-

-

... More
Providing PCC. M-100 with nominal mix of (1:3:6) in foundation with approved quality of stone metal grade-111 (50mm to 25mm size) clean cores sand FM 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, string, curing, taxes USOR BCD and royalty all complete as per building specification and direction of E/I

0.55

-

-

... More
Providing 12 mm thick water proof cement plaster (1:3) in CM 1:3 with clean coarse sand of FM 1.5 with 5% cico or any other approved water proofing compound all complete as per building specification & direction of EЛ.

21.44

-

-

... More
Providing 1.5 mm cement punning on 12 mm thick water proof cement plaster including curing, carriage of water with all leads and lifts as per building specification and direction of E/l

21.44

-

-

... More
Providing Supplying & fixing of C.I. main holl cover size 500X450mm(wt not less tain 25 kg) on septic tanc etc oll complite as per direction of E/L

2

-

-

... More
Providing brickbats of 90 mm to 45 mm size of approved quality in the gap between wall of the pit and earth including cost of materials, labours, taxes, royalty, cairrage at site etc all complete as per standard specifications and direction of the EЛ.

1.27

-

-

... More
Supplying, fitting and fixing vitreous white glazed earthen ware I WC of Perry Hindustan or any other ISS approved make with 100mm HC.I. 'P' TRAP (15) Liters C.I. pull and let go flushing C.I.stern of names or other ISS equivalent make, complete with all fittings, C.. or C.C. brackets 32 MM alkathenae PVC telescopic flush, pipe about 2m long with one brass coupling and clamps G.I. Chain and pull including supplying and fixing a pair or vitreous white glazed earth ware footrest to be fixed in floor 50Gms., 15mm PVC Connection pipe 450 mm Long and the exposed pipe and C.I.stem with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of EA. 580 mm long with 12.5 lit low level PVC cistern

2

-

-

... More
Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of Perry of Hindustan or any other iSS approved make supported on painted C.I. or RS Brackets 32mm CI brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams 32mm PVC waste pipe 750mm long with brass coupling at one end and making plumber joints etc all complete as per specification and direction of EЛ.

2

-

-

... More
Supplying S.W.R.P.V.C. pipes of approved make

-

-

-

... More
1) 110 mm dia - 100 mm PVC Pipe

11

-

-

... More
2) 75 mm dia - 75 mm PVC pipe

11

-

-

... More
Supplying SWR PVC fitting and labour tools and equipments for laying of all size SWR fitting and fixing in trainches / on wall etc all complete as per direction of E/I

-

-

-

... More
110 mm dia

-

-

-

... More
Coupler

3

-

-

... More
Door Tee

2

-

-

... More
Plain Bend

2

-

-

... More
Door Bend

2

-

-

... More
Pipe Clip

4

-

-

... More
Slotted cowl

1

-

-

... More
75 mm dia

-

-

-

... More
Coupler

3

-

-

... More
Door Tee

2

-

-

... More
Plain Bend

2

-

-

... More
Door Bend

2

-

-

... More
Pipe Clip

2

-

-

... More
110 mm x75 mm dia

-

-

-

... More
P. trap ( 110 x 110 mm )

2

-

-

... More
Solvent Cement

2

-

-

... More
SCADA

-

-

-

... More
Ultrasonic level transmitter Designing, Supplying, Installing, Commissioning & testing of Ultrasonic level transmitter CE marked with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement. Range- 11-20 mtrs Output- 4 - 20 mA Power supply -24 V DC ext. Display - Large LCD Accuracy- +/- 0.25 % of Full scale or better Temp.- With Inbuilt temp compensation Enclosure- IP 65

3

-

-

... More
Pressure Transmitter Designing, Supplying, Installing, commissioning & testing of pressure transmitter CE markd with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement. Output- 4 - 20 mA Power supply -24 V DC ext. Display - 4" LCD Accuracy- +/- 0.1 % of Full scale or better Enclosure- IP 67

9

-

-

... More
Power Analyser Designing, Supplying, Installing, commissioning & testing of Power Analyser interfacing to PLC Panel with modbus communicatuion port , as per IEC 62053 and in the prescribed format including mounting arrangement.

9

-

-

... More
PLC Panel Designing, Supplying, Installing, commissioning & testing of PLC Panel. Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories.

9

-

-

... More
PLC based control monitoring and communication software Designing, Supplying, Installing, commissioning & testing of PLC based control monitoring and communication software as per IEC 61131 at Raw water Jackwell / Sump suitable for monitoring and control of Raw water Pumps, Pressure Transmitters, Level Transmitter, Flow Transmitter complete.

6

-

-

... More
Power Cable Designing, Supplying, Installing, commissioning & testing with Terminating & Interfacing of 2 C x 1.5 sq.mm as per IS 694 twisted shielded copper armoured conductor on wall in GI tray or in ground suitable for supplied D. C. Voltage.

500

-

-

... More
Communcation Cable Designing, Supplying, Installing, Commissioning & testing with Terminating and interfacing of CAT 6 as per ISO/IEC -11801 std. cable for networking on wall in GI tray or in ground required Ethernet communication

300

-

-

... More
Signal cable Designing, Supplying, Installing, commissioning & testing with Terminating & Interfacing of 2 Pair x 1 sq.mm as per IS 694 copper Shielded twisted, multistranded armoured cablew on wall in GI tray or on ground.

350

-

-

... More
Designing, Supplying, Installing, commissioning & testing with Terminating & Interfacing of 3 Pairs x1 sq.mm. as per IS 694 copper Shielded, twisted, multi stranded armoured cable on wall in GI tray or on ground

350

-

-

... More
Designing, Supplying, Installing, commissioning & testing with Terminating & Interfacing of 4.5 Pairs x 1.0 sq.mm as per IS 694 copper shielded, twisted, multi stranded armoured cable on wall in GI tray or on ground

350

-

-

... More
Designing, Supplying, Installing, commissioning & testing with Terminating & Interfacing of 8 Pairs x 1.0 sq.mm as per IS 694 copper shielded, twisted, multi stranded armoured cable on wall in GI tray or on ground

350

-

-

... More
Cable Trays Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware in approved manner.

1000

-

-

... More
Cable Trays Designing, Supplying, Installing, Bending, Cutting perforated GI Tray 200 x20 mm x 3 mm thick for laying of cable as per detailed specifications attached

500

-

-

... More
Surveillance System Designing, Supplying, Installing, Commissioning & testing of CCTV IR water proof camera suitable for upto 100 ft. with IR Dome camera, control key board, DVR, Hard Disk, cables, Upt transreceivers etc. complete.

8

-

-

... More
Open channel type ultasonic flowmeter with FIT. Design, Supply, Installation, Testing of open channel type ultrasonic flowmeter. Ultrasonic level transmitter CE maked with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement. Range- 0-5 mtrs Output- 4-20 mA Power Supply - 24 V DC ext Display- 4" LCD Accuracy - +/- 0.25% of Full scale or better Enclosure - IP 68

3

-

-

... More
Design, Supply, Installation, Testing of pH analyser as per IUPAC( International Union for Pure & Applied Chemistry)at A.F. and Interfacing with PLC panel including mounting arrangement. Range: 0-14 pH Accuracy : Better than 0.1% of full scale Supply voltage: 24 V dc Output: 4-20 mA As per IEC 61000-6-2 & IEC 61000-6-3

6

-

-

... More
Turbidity Analyser Design, Supply, Installation, commissioning, testing of Turbidity Anayser as per ISO 7027 scattering light method at A.F. and Interfacing with PLC panel. Turbidity analyser shall comprises of 3 components i.e. sensors,signal distributor and transmitter with indicator. with 2 Outputs, 1 to PLC & anather to Local Display with mounting arrangement. Overall Range : 0-2000 NTU Accuracy : +/- 0.02 NTU Supply Voltage: 230 V ac Output : 4-20 mA

3

-

-

... More
Alum Dosing Design, Supply, Installing commissioning and testing PLC compatible Alum/PAC Mixing, Dosing and monitoring system for Dosing at raw water channel by applying suitable mechanism to control the available turbidity in desired limit. This system includes level switches for tank.

3

-

-

... More
Level Transmitter Designing, Supplying, Installing, Commissioning & testing of Ultrasonic level transmitter CE marked at each filter bed with following technical parameters with PLC panel including mounting arrangement.

11

-

-

... More
Master PLC Panel Design, Supply, Installing, Commissioning & Testing of Master PLC control monitoring and communication panel as per IEC 61131 at Pure Water Sump suitable for monitoring and control of pure water Pumps. Pressure Transmitters, Level Transmitter, PH Transmitter, Turbidity Transmitter, for all pumps installed.

3

-

-

... More
Priming Arrangement Designing, Supplying, Installation, Commissioning & testing with complete priming arrangement for centrifugal pump as applicable & as required shall be done with interface with PLC panels & Further to SCADA system.

3

-

-

... More
Flash Mixer & Clariflocculator Designing, Supplying, Installing, commissioning & testing with operation, controlling & Monitoring of Flash Mixer and Clarifloccutor mechanism interfaced with Master PLC of WTP

3

-

-

... More
Turbidity Meter / Analyser Design, Supply, Installation, Commissioning & Testing of Turbidity Analyser as per ISO 7027 scattering light method at A.F. and Interfacing with PLC panel. Turbidity Analyser shall comprises of 3 components i.e. sensors,signal distributor and transmitter with indicator with 2 outputs, 1 to PLC & another to local display including Mounting arrangement. Overall Range : 0-100 NTU Accuracy : +/- 0.02 NTU Supply Voltage: 230 V ac Output : 4-20 mA

3

-

-

... More
Residual chlorine analyser / Meter Design, Supply, Installation, Testing of Residual chlorine analyser / meter must have automatic sensor cleaning facility at pure water sump and interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors, flow through assembly and transmitter with indicator and gives 2 outputs one to Local display & other to PLC including Mounting arrangement. Overall range : 0-8 mg/l (ppm) Accuracy : 2% of full scale Supply voltage : 230 V ac Output: 4-20 mA Membrane free sennsor of 2 gold plated electrode for long term stability and reference electrode (ag/ Agcl) must be provided to avoid maintenance. IP 65 nema 4 housing protection class required.

3

-

-

... More
SACDA Software Supply, Installation, Commissioning, Testing, Terminating & Interfacing Software Design to PLC and commissioning of SCADA software with required hard tags plus 25% extra and with unlimited soft Tags & life time licence Development version

1

-

-

... More
Developing/ Programming charges to install the software as per logic define by the dept

1

-

-

... More
Supply, Installation, Testing, Terminating & Interfacing Centralised Historian Server grade Historian PC with Window 7 or latest window operating system & Historian software development cost etc. complete

1

-

-

... More
Supply, Installation, Testing, terminating & Interfacing Secondary Computer station etc.

1

-

-

... More
Supply, Installation, Testing, Integration & Commissioning of 46" LCD monitor at Conf. Room for display of total water system (Online).

1

-

-

... More
PLC Panel suitable for Wireless communication Designing.supplying, Installing commissioning & testing of following equipments with satisfactory test and trial of PLC Panel control, monitoring and communication system along with PLC Panel at Central monitoring system.

2

-

-

... More
Solar Panel with Battery Designing,Supplying,installing commissioning & testing of photovoltaic solar panel with its charger, MS Stand for mounting solar panel so as to have maximum exposure of sunlight for desired location and maintenance free battery wit 3 days battery backup.

3

-

-

... More
Valves Actuator Providing, erecting electrical valve actuators totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly & with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction motor working on 440 Volts +/- 10% 3 phase, 50 Hz AC of intermittent duty rating S-2 insulation class "F" and temp rise restricted to class "B" with IP-67 protection class suitable for DOL starting load margin. The torque rating of reduction gear box shall be atleast 1.5 times max. toeque required for opening & closing of valve. Electric valve Actuator for non rising spindle type sluice valve, PN-1 & PN 1.6 rating For Valve Size

-

-

-

... More
200 mm dia.

2

-

-

... More
250 mm dia.

4

-

-

... More
300 mm dia.

2

-

-

... More
350 mm dia.

4

-

-

... More
400 mm dia.

2

-

-

... More
450 mm dia.

6

-

-

... More
EMP

-

-

-

... More
Ambient Air Quality Monitoring- For parameters – PM-2.5 & PM-10, SO2, NO2, CO from NABL approved laboratory and submission of report complete in all respect.

48

-

-

... More
Water Quality Analysis– Collecting representative sample and Physical & Chemical testing of Parameter from NABL approved laboratory as per CPHEEO manual: PH, TDS, Electrical Conductivity (EC), Taste & Odour, turbidity, magnesium, Total hardness, total alkalinity, chloride, Dissolved Oxygen (DO), sulphate, nitrate, fluoride, Calcium, Iron, Pesticide, Manganese, Cooper, Aluminium, Residual Chlorine, Zinc, phenolic compound, Arsenic, Cadmium, Chromium, cyanides, lead, selenium, Mercury.

16

-

-

... More
Collecting representative sample and Bacteriological Parameter testing of water from NABL approved laboratory as per CPHEEO manual: Total coliforms, faecal coliforms

16

-

-

... More
Ambient Noise Quality Monitoring - To Identify sources of noise, Noise due to traffic/transportation of vehicles, Noise due to heavy equipment operations, Duration and variations in noise over time etc. the equivalent noise levels shall be monitored (Lday and Lnight in Leq dBA) from NABL approved laboratory and submission of report complete in all respec

48

-

-

... More
Miscellaneous expenses for consturction phase EMP Implementation

1

-

-

... More
MISCELLANEOUS

-

-

-

... More
Hand railling for Existing Approach Bridge at Intake well Providing and fixing G.I. pipe railing having 1.0 M height consisting 50 x 50 x 6 mm thick M.S. angles as verticals at 1.5 M c/c and additional posts at every corner with 3 rows of 25 mm dia G.I. pipes of medium class variety as horizontal and painting 3 coats of oil paint over 1 coat of anticorrosive paint of approved colour and shade including cost of all labour, transporting bends to curved shape, etc.complete.

72

-

-

... More
Internal Plaster for Chemical room (3 X 3) at Existing WTP Providing 12 mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, Curing with all leads & lifts of water, scaffolding, taxes and royalty all complete as per building specification & direction of E/I.

40.84

-

-

... More
Water proofing for Chemical room (3 X 3) at Existing WTP Providing average 115mm. thick lime terracing (24 lime :36 surkhi:100 brick khoa) well beaten and compacted including maintaining proper level & slope, making ghundi with finishing treatment, cost of carriage,curing, royalty & taxes all complete as per building specification & direction of E/I.

9

-

-

... More
TOTAL CARRIAGE

-

-

-

... More
Sand

1640.03

-

-

... More
Aggregate

2819.61

-

-

... More
Cement

3207

-

-

... More
Bricks

198.29

-

-

... More
OPERATION & MAINTENANCE

-

-

-

... More
Carrying out operation & maintenance of work for a period of 5 years including cost of all supervisory sraff, materials, chemicals, equipment, consumables, including sludge analysis and disposal, establishment, maintenance of complete instrumentation, control and automation system with manpower to operate the WTP & pumping stations (24x7) data transmission cost to centralized SCADA center,Comprehensive maintenance of field instrumentation, control & automation at all location etc complete as per directed by Engineer - in - Charge (The bid will be rejected if the bidder has not quoted O&M cost in the following rows).

-

-

-

... More
Operation and Maintenance for 1st Year

1711850

-

-

... More
Operation and Maintenance for 2nd Year

1751739

-

-

... More
Operation and Maintenance for 3rd Year

1791629

-

-

... More
Operation and Maintenance for 4th Year

1831518

-

-

... More
Operation and Maintenance for 5th Year

1871407

-

-

... More
Max guaranteed electricity consumption ( please quote quantity in KWH/Year for the following row). This cost will be used for evaluation

-

-

-

... More
Operation and Maintenance for 1st Year

6.25

-

-

... More
Operation and Maintenance for 2nd Year

6.25

-

-

... More
Operation and Maintenance for 3rd Year

6.25

-

-

... More
Operation and Maintenance for 4th Year

6.25

-

-

... More
Operation and Maintenance for 5th Year

6.25

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.