Jharkhand Urban Infrastructure Development Company Limited Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Jharkhand Urban Infrastructure Development Company Limited Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date23 Feb 2024
Closing Date30 Apr 2024
Tender Amount₹ 1,30,78,04,494 
Notes
Download

Costs

Summary

Design Build And 5 Year Operation Service Of Water Supply System

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
E/W in excavation of foundation trenches of toe wall, spillway, head regulator, outlet, intake well etc. as per designed section in all kinds of soil including moorum soil, soil mixed with kankar, pebbles and boulder uoto 300 mm size and disposal of the same (beyond 50m away from the edge of the trenches) with initial lead of 150mm and initial lift of 1.5 m as per specification and direction of E/I.

2630.71

-

-

... More
Supplying and laying gravel filter (size 5mm to 15 mm) in filter blanket and in the toe drain (in horizontal portion) of the dam as per design, drawing including the cost of material royality all taxes etc but excluding the cost of carriage all complete as per specification and direction of E/I.

1920.85

-

-

... More
Supplying and laying (properly as per design and drawing) rip-rap with good quality of boulder duly packed including the cost of materials, royality all taxes etc. but excluding the cost of carriage all complete as per specification and direction of E/I.

4859.92

-

-

... More
Providing random rubble stone masonry in cement motar 1:4 in founation and plinth with hammer dressed stone of less than 0.03 cum in volume and clean sand of F.M 2 to 2.5 including cost of screening, raking out joints to 20 mm depth, curing taxes and royalty all complete job as per building specification and direction of E/I.

780.98

-

-

... More
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.

571.11

-

-

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and lifts including cost of all material , labour, royalty and taxes all complete as per building specification and direction of E/I.

1024.95

-

-

... More
P.C.C Grade M - 20 using batching plant & manual placing

9020.77

-

-

... More
Manufacturing, providing and supplying spirally welded/ ERW/ SAW/ fabricated M.S pipes (commercial quality) including procurements of plates, gas cutting to required size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming 'V' edge on both ends of pipes in all respects etc. complete as per IS - 3589 and IS - 5504 as applicable as per specification (No negative tolerance in thickness is pernissible).- 400mm

81

-

-

... More
Lowering, laying in position to correct line and level including M.S pipes with/ without any outcoating on pedestals or chairs upon prepared formation. The rate to include loading, unloading, hoisting, marginal cutting wherever required, assembling and tack welding and transportation upto 500 M etc. completed as specified.c

81

-

-

... More
Providing and applying first coat of interol 49 W emaline 05/58 pipe coat or any other equivalent approved paint to the internal surface of pipe line at site.

101.8

-

-

... More
Providing double flange sluice valve (Size 50 mm to 1200 mm) confirming for IS - 2906/14846 including worn gear arrangement as per test pressure stainless steel spindle, caps transportation etc. all complete. Without bypass arrangement - PN - 1.6- 400 mm

6

-

-

... More
Supplying labour and tools for fixing C.I sluice valve in trenches with a pair of C.I tail piece, including making lead caulked joints and flanged joint as per I.S.S specification, including supplying all jointing materials (Pig lead confirming to I.S.S 782 - 1978, yarn confirming to I.S.S 6587 - 1972 and nuts and bolts confirming to I.S.S 1364 - 1983) including drilling holes in flanges if required as per specification and direction of E/I.

6

-

-

... More
Providing Plain cement concrete (Grade M-25) in open foundation all complete as per drawing and technical specification

1961.02

-

-

... More
Reinforced cement concrete (Grade M-25) in substructure all complete as per drawing and technical specification.

1583.34

-

-

... More
Providing shuttering including strutting , proping etc its and removal after use in foundation as per specification and direction of E/I.

5432.02

-

-

... More
Providing shuttering including strutting , proping etc and removal after use in superstructure portion of various components of barrage work as per specification and direction of E/I.

5233.44

-

-

... More
Supplying, Fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications. 10mm to 16mm dia.

154.73

-

-

... More
Earth work in filling foundation trenches or back filling of masonry structure with pervious soil in layer not exceeding 150 mm thick well watered, rammed and fully compacted and finally dressed with earth obtained from borrow pits beyond 150m lead but upto 1/2 Km with all lifts and carriage by truck including, loading, unloading, spreading, construction and maintenance of haul road etc. as per specifiction and direction of E/I.

5261.42

-

-

... More
Supplying, fitting and fixing copper strip of 16 guage of approved quality (with 99% purity) in expansion joints complete job as per specification and direction of E/I.

219.09

-

-

... More
Providing weep holes with dry graded stone filter of 20mm to 40mm size in abutment and wing wall as per specification and direction of E/I

356

-

-

... More
Supply and laying 150 mm dia R.C.C (NP-2) perforated pipe in under drainage canal lining as per specification and direction of E/I.

348

-

-

... More
Supplying 65mm dia G.I pipe including pipe, including cutting and placing in position. Average length = 1.93 M as per specification and direction of E/I.

63.69

-

-

... More
Supplying and fitting position of NR Valve (65mm) as per specification and direction of E/I.

33

-

-

... More
Cost of Dewatering and Diversion as per requirement (L.S) for Weir

1

-

-

... More
INTAKE

-

-

-

... More
E/W in excavation of foundation trenches of toe wall, spillway, head regulator, intake well, outlet etc. as per designed section in all kinds of soil including moorum soil, soil mixed with kankar, pebbles and boulders upto 300 mm size and disposal of the same in country side with truck beyond initial lead of 150 m but upto 1 km with all lifts including loading, unloading, construction and maintainance of haul road etc. as per specification and direction of E/I.

-

-

-

... More
Lift 0 to 1.5 M

1201.34

-

-

... More
1.5 to 3 m

286.56

-

-

... More
3 to 4.5m

264.94

-

-

... More
4.5 to 6.0 m

244.17

-

-

... More
6.0 to 7.5 m

224.24

-

-

... More
E/W in excavation of foundation trenches of toe wall, spillway, head regulator, intake well, outlet etc. as per designed section in hard rock where blasting is needed and disposal of excavated rock by truck beyond initial lead of 150 m but upto 1 km with all lifts including loading, unloading, and stacking properly in approved stack yard and in approved stak size as well as construction and maintainance of haul road etc. as per specification and direction of E/I.

-

-

-

... More
7.5 - 9.0 m

205.17

-

-

... More
9.0-10.5 m

186.94

-

-

... More
10.5-12.00 m

169.56

-

-

... More
12.00-13.5 m

153.03

-

-

... More
13.5 -15.0m

137.34

-

-

... More
15.0-16.5m

122.51

-

-

... More
16.5-18.0m

108.52

-

-

... More
18.0-19.5m

72.35

-

-

... More
Plain Renforced Cement Concrete in sub structure complete as per drawing and technical specifications

-

-

-

... More
M-20 - for Sumpwell

14.47

-

-

... More
Providing and laying P.C.C. or R.C.C. M-25 with nominal mix (1:1:2) in various components of dam superstructure with -do- complete job as per specification and direction of E/I.

-

-

-

... More
M-20 - for Sumpwell

72.35

-

-

... More
Providing and laying P.C.C. or R.C.C. M-30 with nominal mix (1:1:2) in various components of dam superstructure with -do- complete job as per specification and direction of E/I.

473.29

-

-

... More
Providing TOR steel reinforcement of 10 mm, 12 mm & 16 mm dia bars as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire removal of rust, placing the rods in position (including carriage of bars to work site) all complete as per building specification and direction of E/I b) 12 mm (TMT coil Fe500)

250.71

-

-

... More
Inside painting Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floor and taxes all complete as per building specifciaction and direction of E/I.

37.7

-

-

... More
Outside Snowcem Providing two coat of snowcem of approved shade and make over a coat of cement primer on new surface including washing cleaning and preparing the walls, scaffolding, curing and taxes all complete as per building specification and direction of E/I

75.4

-

-

... More
Ceiling whitewash Whitewasing three coats over new surface with approved quality of lime incuding cost of cleaning surface throughlly and removing the scales of smoke and mosh marks with jhama rubbing, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/I.

63.59

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters.

4.2

-

-

... More
Window Supplying, fitting and fixing fully glazed steel door, windows or ventilations of standards rolled 'z' and mullian steel sections and size a per IS 1038 Joints met and welded with 100*16*3 mm MS lugs fixed in cement concrete (1:2:4) blocks 15*10*10 cm, size including cost of oxidized iron fittings with hinges, handle per steps, catch springs, 3 mm thick plain glass pens with aluminium beads and inner frame fixed with lugs with 20 mm long 6 3mm GI counter sunk machine screw and nuts and applying a coat of red lead paint carriage to ork site, hoisting and placing in position in all stories and taxes all complete as per building specification and diection of E/I

6.75

-

-

... More
Concertina Door Providing, detailing, and fabricating as per specifications, transporting to site and erecting MS Openable / Sliding / Ornamental Entrance Gates including track and wheel, locking arrangement, fixing bolts, nuts, washers, cleats, stiffeners, gussets decorative balusters, arrow heads etc. and all necessary operations like straightening, bending, cutting, drilling, grinding, machining if specified, welding etc. complete weighing 25 to 30 kg/Sqm, including cleaning, Grinding and removing the welding burr and preparing surface and applying one coat of red oxide zinc chromate primer and one coat of Synthetic Enamel paint after fabrication and second coat of Synthetic Enamel paint after erection, with approved colour, shade and brand etc. including touching up with primer etc. complete as directed by Engineer In Charge. Providing and fixing 750mm dia concertina barbed razeer type coil of 19mm wide ribbon with thickness 5 SWG and central core wire of 12 SWG with anti rust coating, supported over 5 rows of barbed wires of 14 SWG having two ply four points at 75 mm c/c, fixed to Y shape angle bracket placed at 2.5m c/c (leg of Y should be 0.51 m long and 0.23 m embeded in concrete, wing of Y should be 0.475 m long having a distance of 0.58 m between the two wing on the top) made up of 50mm x 6 mm M.S. angle embeded in cement concrete bed block of size 300mm x 300mm x 300mm. The concertina coil should be fixed to angle with M.S. Flat 25mm x 5mm thick on both the sides as runner all steel work shall be applied with one coat of red oxide zinc chromate primer and two coat of Synthetic Enamel paint etc. complete as directed by Engineer In Charge

12.25

-

-

... More
P&F of Heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaust fan,IS:2312 marked in existing opening including making connections testing etc. as required. 450 mm sweep(900 RPM)

4

-

-

... More
Five course water proofing on roof a) Surface Preparation b) 1st Coat c) 2nd Coat d) Protection of treated surface with PCC e) Groove of PCC surface

63.59

-

-

... More
Plain Renforced Cement Concrete in sub structure complete as per drawing and technical specifications PCC M25 Grade

46.08

-

-

... More
Electrically Operated Circular or Rectangular Travelling Crane (Single Girder) Providing, Erecting and Commissioning Single Girder electrically Operated Circular/Rectangular over head travelling crane with 6 m Lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54 control panel and down pendant control block. 10 Tonne Capacity Above 8 m up to 10 m span

1

-

-

... More
Square Bar / Rail :- Providing, erecting and fixing square bar of EN 8 as rail for overhead crane on provided track, girder/continuous corbel beam, including supporting plate and "J" bolts. 50 x 50 mm (EN 8)

12

-

-

... More
Providing 50 mm thick cement concrete flooring (1:2:4) with 20 mm to 6mm, size graded Stone chips finished with flooring coat of neat cement in panels -do- 100 mm thick I.P.S. flooring.

127.17

-

-

... More
Sluice Gate of 1.1 M X 0.6 M SS 316 Electric Actuator Operated Rising type Single Faced Sluice Gates

2

-

-

... More
Sluice Gate of 0.75 M X 0.75 M SS 316 Electric Actuator Operated Rising type Single Faced Sluice Gates

1

-

-

... More
Dewatering Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel),

27750

-

-

... More
Providing, constructing coffer dam in river basin / dam storages as per type design including excavation, filling the middle portion with B.C. soil (in gunny bags if required). Providing impervious / semipervious materials on both sides of B.C. soil (in gunny bags if required) including ramming, compacting to the satisfaction of Engineer-in-charge till the completion of work including dismantling coffer dam after completion of works and disposing off the material as directed by the Engineer-in-charge.

20475

-

-

... More
Note : Pay line maximum. Top width payable shall be 2 Mtr. and maximum payable side slopes shall be 1.5 horizontal to 1 vertical, if the constructed top width of the side slopes are less, then the measurements at actual are payable. Extra top width or flat slopes are not payable. Contractor is free to use ballies, plastic sheets, piles, pipes, CGI sheets for supporting hearting materials instead of impervious/ semi-pervious hearting materials for which no extra payments shall be payable.30% payment shall be withheld for dismantling of coffer dam.

-

-

-

... More
Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete.

21

-

-

... More
Providing M.S. bar mesh prepared out of 16 mm dia M.S.bar at 15 cm. c/c both ways, welded to flanged ring including tack welding of bars and fixing the same with nuts and bolts on open faces of outlet/inlet pipes in the sump or reservoir,etc. complete as directed by Engineer-in-charge.

100

-

-

... More
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.

-

-

-

... More
1.5 to 2.5 m

418

-

-

... More
2.5 to 3.5 m

209

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.

-

-

-

... More
M-200 for PCC

214.5

-

-

... More
Centering and shuttering including strtting, propping etc. and removal of formwork for foundation PCC

458.48

-

-

... More
Providing and laying in position ready mix or site batched design mix cement concrete for RCC work; using coarse aggregate and fine aggregate derived from natural sources,Portland Pozzolana/ Ordinary Portland/ Portland Slag Cement, admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering.shuttering, finishing and reinforcement as per direction of the engineer-in-charge.

674.41

-

-

... More
Centering and shuttering including strtting, propping etc. and removal of formwork for Columns

396

-

-

... More
Centering and shuttering including strtting, propping etc. and removal of formwork for Beams

396

-

-

... More
PIPING ARRANGEMENT AND ROAD RESTORATION

-

-

-

... More
Providing and supplying ISI mark centrifugally cast (spun) ductile iron pipes of 100 mm and above all diameter for water works with socket and spigot ends confirming to IS.8329/2000 in standard working lengths of 4.5, 5.5 & 6.0 m for classification K-7 suitable for push on joint (Rubber gasket D jointing) with cement mortar lining inside the pipes with outside zinc and bituminous coating.

-

-

-

... More
100 mm dia

131271

-

-

... More
150 mm dia

20293

-

-

... More
200 mm dia

10436

-

-

... More
250 mm dia

3576

-

-

... More
300 mm dia

4147

-

-

... More
350 mm dia

1751

-

-

... More
400 mm dia

39

-

-

... More
450 mm dia

94

-

-

... More
Providing and supplying ISI standard D.I specials & fitting with sealing rubber gasket of S.B.R., complete with cast iron follower gland and M.S nut & bolts coated or otherwise protected from rusting and suitable for D.I pipes complete as per I.S-9523.

253327.69

-

-

... More
Providing and supplying ISI mark centrifugally cast (spun) ductile iron pipes of 100 mm and above all diameter for water works with socket and spigot ends confirming to IS.8329/2000 in standard working lengths of 4.5, 5.5 & 6.0 m for classification K-9 suitable for push on joint (Rubber gasket D jointing) with cement mortar lining inside the pipes with outside zinc and bituminous coating.

-

-

-

... More
Dia 200 mm

37

-

-

... More
Dia 250 mm

3434

-

-

... More
Dia 300 mm

245

-

-

... More
Dia 350 mm

265

-

-

... More
Dia 400 mm

1515

-

-

... More
Dia 500 mm

1990

-

-

... More
Dia 600 mm

4000

-

-

... More
Supplying labours, tools, tackles, lubricants etc. for laying and jointing C.I./S.S. tyton pipes intrenches without supplying rubber gasket and making gasket joints including providing night guard, barrier, and red light to safe guard against accidents, all complete as per design, specification and direction of E./I.

-

-

-

... More
Dia 100 mm

131271

-

-

... More
Dia 150 mm

20293

-

-

... More
Dia 200 mm

10473

-

-

... More
Dia 250 mm

7010

-

-

... More
Dia 300 mm

4392

-

-

... More
Dia 350 mm

2016

-

-

... More
Dia 400 mm

1554

-

-

... More
Dia 450 mm

94

-

-

... More
Dia 500 mm

1990

-

-

... More
Dia 600 mm

4000

-

-

... More
Supplying labours, tool and tackles for testing of laid CI or UPVC or HDPE or AC or DI pressure pipe all complete as per specification direction E/I.

-

-

-

... More
Dia 100 mm

131271

-

-

... More
Dia 150 mm

20293

-

-

... More
Dia 200 mm

10473

-

-

... More
Dia 250 mm

7010

-

-

... More
Dia 300 mm

4392

-

-

... More
Dia 350 mm

2016

-

-

... More
Dia 400 mm

1554

-

-

... More
Dia 450 mm

94

-

-

... More
Dia 500 mm

1990

-

-

... More
Dia 600mm

4000

-

-

... More
Labour charge for one cutting of cast iron/DI pipe & specials including supplying, necessary tools and plants, chipping or filling the surface finish as per specification and direction of E/I.

-

-

-

... More
Dia 100 mm

2626

-

-

... More
Dia 150 mm

406

-

-

... More
Dia 200 mm

210

-

-

... More
Dia 250 mm

141

-

-

... More
Dia 300 mm

88

-

-

... More
Dia 350 mm

41

-

-

... More
Dia 400 mm

32

-

-

... More
Dia 450 mm

2

-

-

... More
Dia 500 mm

40

-

-

... More
Dia 600mm

40

-

-

... More
Providing double flange sluice valve (50 mm to 1200 mm) confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps transportation etc all complete.

-

-

-

... More
Scour Valve

-

-

-

... More
100 mm dia

48

-

-

... More
Providing double flange sluice valve (50 mm to 1200 mm) confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps transportation etc all complete.

-

-

-

... More
Dia 100 mm

29

-

-

... More
Dia 150 mm

19

-

-

... More
Dia 200 mm

33

-

-

... More
Dia 250 mm

16

-

-

... More
Dia 300 mm

5

-

-

... More
Dia 350 mm

5

-

-

... More
Dia 400 mm

5

-

-

... More
Dia 450 mm

1

-

-

... More
Dia 500 mm

3

-

-

... More
Dia 600 mm

4

-

-

... More
Supplying labour and tools for fixing C.I. Sluice Valves in trenches with C.I. tail piece, including lead caulked joints and flanged joints as per I.S.S. specifications, including supplying all jointing material (pig lead confirming to I.S. S. 782-1978, yarn confirimg to I.S.S. 6587-1972 and nuts and bolts confirming to I.S.S.1364-1983) including drilling holes in flanges if required as per specifications and direction of E./I.

-

-

-

... More
600mm dia

4

-

-

... More
Lowering, laying and jointing in position following C.I.D/F Reflux valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)

-

-

-

... More
100 mm dia

77

-

-

... More
150 mm dia

19

-

-

... More
200 mm dia

33

-

-

... More
250 mm dia

16

-

-

... More
300 mm dia

5

-

-

... More
350 mm dia

5

-

-

... More
400 mm dia

5

-

-

... More
450 mm dia

1

-

-

... More
500 mm dia

3

-

-

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve class PN 1.6 of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (NonToxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside fasteners - CS/ Galvenised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended upto date) PN 1.6 ratings. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.

-

-

-

... More
50 mm dia Air Valve

3

-

-

... More
Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS14845 as per MJP’s standard specificationscombined with screw down isolating valve,small orifice elastic ball resting on a gunmetal orifice nipple, large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled, including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc. complete.

-

-

-

... More
80 mm dia Air Valve

6

-

-

... More
100 mm dia Air Valve

23

-

-

... More
150 mm dia Air Valve

25

-

-

... More
Earth work in excavation (as per I.S. 3114/1965) for laying of different types and size of pipes so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of Engineer-in-charge (b) For classification of soil item -B

140280.91

-

-

... More
Extra for earthwork in all kinds of soil for each additional lift of 1m or part there of over the initial lift of 1.5m as per specification and direction of Engineer-in-Charge. From 1.5 m to 2.5 m

1447.05

-

-

... More
Earthwork in excavation of foundation trenches as per design section in ordinary or soft rock (vide classification of soil item-C) and disposal of excavated materials so obtained (50 m away from the edge of the trenches) with initial lead of 150 m and initial lift of 1.5m as per specification and direction of E/I.

1610.1

-

-

... More
Earthwork in back filling the trenches after laying different types and sizes of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer -in- charge.

115387.55

-

-

... More
Supplying tools and cutting road as well restoring the same as per specification and direction of E/I.

-

-

-

... More
(a) Pucca Road (Except black top only taken out material to be used) for cutting road as per requirement.

98585.4

-

-

... More
Filling in foundation trenches and plenth in layers not eceeding 150 mm tick well watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specifications and direction of E/I.

14757.12

-

-

... More
Dismantling of flexible pavements and disposal of dismantled materials upto 1000 m stacking serviceable and unserviceable materials separately (asphaltic road)

2003.49

-

-

... More
Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15 meter lead and disposal of un-serviceable materials with all leads all complete as per direction of E/I

5502.96

-

-

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I.

7947.56

-

-

... More
Plain/Reinforced cement concrete in substrycture complete as per drawing and technical specifications M 20

5502.96

-

-

... More
Construction of RCC valve chamber for different types of valves including earthwork excavation, 100 mm PCC M10 (1:3:6 i.e 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as levelling course, RCC M20 grade (1:1½:3 i.e. 1 Cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal) size for base slab, side wall & cover slab all 125 mm thick with C.I. surface box with hinged cover 100x100x75 mm (deep), including cost of steel reinforcement not less than 80 kg per cum CC, form work, proper curing of concrete work, complete in all respect as per standard specifications and drawings and as directed by Engineerin-charge 1200X1200X1300mm (Depth)

54

-

-

... More
Construction of RCC valve chamber for different types of valves including earthwork excavation, 100 mm PCC M10 (1:3:6 i.e 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as levelling course, RCC M20 grade (1:1½:3 i.e. 1 Cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal) size for base slab, side wall & cover slab all 125 mm thick with C.I. surface box with hinged cover 100x100x75 mm (deep), including cost of steel reinforcement not less than 80 kg per cum CC, form work, proper curing of concrete work, complete in all respect as per standard specifications and drawings and as directed by Engineerin-charge 1300x1300x1450mm (Depth)

59

-

-

... More
Construction of RCC valve chamber for different types of valves including earthwork excavation, 100 mm PCC M10 (1:3:6 i.e 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as levelling course, RCC M20 grade (1:1½:3 i.e. 1 Cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal) size for base slab, side wall & cover slab all 125 mm thick with C.I. surface box with hinged cover 100x100x75 mm (deep), including cost of steel reinforcement not less than 80 kg per cum CC, form work, proper curing of concrete work, complete in all respect as per standard specifications and drawings and as directed by Engineerin-charge 1400x1600x1750mm (Depth)

21

-

-

... More
Bituminous Concrete Grading - II with VG-30 Grade Packed Bitumin - Providing and Laying Bituminous concrerte with higher capacity batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @5.4% of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control with smooth wheeled vibratory and tandem rollers to achieve the desired compaction as per MORT&H specifications clause no. 507 complete in all respects.

921.32

-

-

... More
Tack Coat over DGBM - Providing and applying tack coat with bitumen emulsion pressure distributor at the rate of 0.20 kg per sq.m on the prepared bituminous/granular surface cleaned with mechanical broom.

30710.9

-

-

... More
Dense Graded Bituminous Macadam - Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type MMP producing an average output of 75 tonnes per hour using crushed aggregate of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic power finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respect) with modified graded bitumen.

1966.45

-

-

... More
Prime Coat over WMM- Providing and applying primer coat with bitumen emulsion on prepared surface of granular base including clearing of road surface and spraying primer at the rate of 0.60 kg per sq.m using mechanical means.

26219.25

-

-

... More
WMM- Wet mix macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant . Carriage of mix material to site, laying in uniform layers with paver in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density)

6554.81

-

-

... More
GSB- Granular Sub-Base with Coarse Graded Material (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place to achieve the desired density. For grading-I Material

6554.81

-

-

... More
Supplying, transporting and fixing S.P. fire hydrants including mouth piece, duck foot bend, S.V. as per specifications & drawing, fixing flanged socket, supplying and laying C.I./ M.S. pipe up to 2 m. length and jointing the same with spun yarn, molten lead, including caulking etc. complete as directed & as specified by Engineer In Charge. (as per IS : 908) Note: Construction of valve chamber will be paid separately

11

-

-

... More
MECHANICAL COMPONENTS

-

-

-

... More
Supply and delivery of Vertical water/oil lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging the following duty condition as given below due to all causes with surface discharge head confirming to IS 1710 and as amended as on date with accessories as per IS 5120/1977 ( Reaffirmed 2011 ) and as amended thereafter to suit the site condition. The speed, No. of stages, sizes of column pipes and line shaft indicated is based on site condition prevailing during investigation. The pump should be supplied with non reversible ratchet pin housing safety clutch, suction strainer etc. The Pump Bowl assembly shall be with bronze impeller running at 1450 RPM. The pump includes suitable head shaft, suitable 1.5 metre long SS line shaft required Nos. to suit the well depth, Rubber line shaft bearing of required Nos., C.I Bearing retainer of required Nos., 100 litre HDPE Pre- lubricating tank with 20mm PVC Rigid pipe connection along with GM gate valves, Suitable ERW column pipe of each 1.5m long of required Nos. to suit the well depth, Suction bell mouth of suitable size, M.S. clamps suitable for column pipe/line shaft -2 set and Spanner - 1 set etc complete 14880 LPM and 30 m Head

3

-

-

... More
Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading fromrailway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) (a) 300 mm dia

3

-

-

... More
Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)

3

-

-

... More
Air Release Valve: Providing & supplying air valves as per IS 14845-2000 & MJP's standard specifications double orifice type combined with isolating sluice valve mounted in horizontal position and operated by wheel gearing, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcannite ball seating on moulded seat ring, inlet face & drilled, excluding all taxes (central & local), insurance, third party inspection charges, loading, unloading, transportation upo to departmental store / site etc. complete.

-

-

-

... More
80 mm dia PN-1

2

-

-

... More
Lowering, laying and fixing in proper alignment and position all types of CI air valves as directed by engineer in charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing etc complete. (Rate for all class of valves.)

2

-

-

... More
Providing, erecting electric Valve actuators totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically disengage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction motor working on 440 Volts +/- 10%, 3 phase, 50 Hz AC of intermittent duty rating S-2, insulation class "F" and temp rise restricted to class "B" with IP - 67 protection class suitable for DOL starting and with three thermostat and 30% over load margin. The torque rating of reduction gear box shall be atleast 1.5 times max. torque required for opening and closing of valve with integral starter controls having four limit switches 1 for OPEN, 1 for CLOSE & 2 Nos for intermidiate positions for interlocking etc complete. VA -1 - Electric Valve Actuator for non rising spindle type sluice valve, PN 1 & PN 1.6 rating For Valve Size Inlet - 300 mm dia

15

-

-

... More
Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR.

-

-

-

... More
300 mm sweep(900/1400 RPM)

6

-

-

... More
Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge.

10

-

-

... More
Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casting pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specification. Discharge 301 to 325 LPS and head 61 to 70 M

3

-

-

... More
Supplying non clog submersible pump suitable for sewage liquid waste application with standard MOC and duty points.

2

-

-

... More
Providing and fixing M.S. chequerred plate flooring of following thickness supported on M.S. angles (25 x 25 x 5 mm size) including welding, cutting and fabricating the plates to the required square or rounding shape, making holes in the plate, including providing and applying 3 coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge.6 mm thick

30

-

-

... More
Providing double flange sluice valve (50 mm to 1200 mm) confirming for IS 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps transportation etc all complete. 250 mm dia (without by-pass arrangement - PN-1.6)

6

-

-

... More
Lowering, laying and fixing in proper alignment and position all types of CI air valves as directed by engineer in charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing etc complete. (Rate for all class of valves.)

6

-

-

... More
Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading fromrailway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) 250 mm dia (without by-pass arrangement- PN-1.6)

3

-

-

... More
Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)

3

-

-

... More
Supplying labours, tools, tackles, lubricant etc. for laying and jointing DI/C.I.S/S Tyton pipes (class LA) trenches without supplying rubber gasket and making gasket joints including providing night guard, barrier and red light to safe guard against accident, all complete (Pipe to be supplied departmentally free of cost and laying of pipes is to be done as per (I.S.S. 3114 -1985) as per design, specification and direction of E/I. 250 mm dia

80

-

-

... More
Labour charge for one cutting of cast iron/DI pipe & specials including supplying, necessary tools and plants, chipping or filling the surface finish as per specification and direction of E/I. 250 mm dia

5

-

-

... More
Air Release Valve: Providing & supplying air valves as per IS 14845-2000 & MJP's standard specifications double orifice type combined with isolating sluice valve mounted in horizontal position and operated by wheel gearing, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcannite ball seating on moulded seat ring, inlet face & drilled, excluding all taxes (central & local), insurance, third party inspection charges, loading, unloading, transportation upo to departmental store / site etc. complete.

-

-

-

... More
80 mm dia PN-1

2

-

-

... More
Supplying labour & tools for fixing C.I. Double acting Air Valve in trenches as per specification and direction of E./I.

2

-

-

... More
EOT Crane : - Providing, Erecting and Commissioning Single Girder electrically Operated Circular/Rectangular over head travelling crane with 6 m Lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54 control panel and down pendant control block.

-

-

-

... More
5 T Capacity - Above 6 m upto 8 m span.

1

-

-

... More
Square Bar / Rail :- Providing, erecting and fixing square bar of EN 8 as rail for overhead crane on provided track, girder/continuous corbel beam, including supporting plate and "J" bolts. 40x40 mm

20

-

-

... More
Providing and supplying ISI mark centrifugally cast (spun) ductile iron pipes of 100 mm and above all diameter for water works with socket and spigot ends confirming to IS.8329/2000 in standard working lengths of 4.5, 5.5 & 6.0 m for classification K-9 suitable for push on joint (Rubber gasket D jointing) with cement mortar lining inside the pipes with outside zinc and bituminous coating.

-

-

-

... More
300mm dia (delivery line of each pump)

80

-

-

... More
Providing and erecting Ductile Iron Push on special confirming to IS 9523:2000 - All DI PN :16.0 Dismanting Joints

3

-

-

... More
ELECTRICAL COMPONENTS

-

-

-

... More
Supply, Installation, testing and commissioning of 11 KV Double Pole structure With Air Break SWITCH having following specifications : (a) DP : Double pole structure made of two nos. 9 meter long PCC poles (400 Kg) & 7 nos. MS Channel each of size 100mmx50mmx2500mm complete with earthing of the structure as per REC standards in all respect with nuts, springs washers, clamps as required. (b) GO:Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3 phase, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 Nos pin insulator ,GI pipe of suitable length for operation. (c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set/drop out 11kv barrel fuses mounted on 6 no pin insulators (d) LA:3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. (e) JUMPERS: 3 no 11kv acsr conductors mounted on pin type insularors as required. GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’

3

-

-

... More
VCB Breaker Panel, 630A, 40KA/1sec, 11 KV with IDMTL Relay (O/C, E/F and motor protection relay) and two nos auxuiliary Relay. Panel with CT PT, Ammeter Voltmeter. The VCB shall be conform to routine test as per IEC 56 and IS 13118. The panel along with breakers should conform to Routine Test as per IEC 298 and IS 3427. Panel should have motorized as well as manual operation. Aux voltage: 110V DC. Incomer rating shall be 1250A and quantity is Two number and One number Bus Coupler. Outgoing Motor feeder is Four nos and one power feeder (Total out going feeder shall be 5nos), Rating shall be 630A. Suitable for Indoor application with Aluminium Busbar

3

-

-

... More
Supply installation testing & Commissioning of star rated Copper wound distribution Transformer ( All the distribution transformer must be star rated as per notification of (BEE) ministry of power, Goverenment of India) of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cable box & LT cable boxes, Off -LTC (+5% to - 10% @ 2.5%) temperature rise of 40 degree C in oil / 45 degree C in winding , ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953 , Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, CTL testing charges & Inspection charges shall be reimbursed by the department to the contractor as per actual expenditure. All as per pre approved by Engineer in charge.

-

-

-

... More
200KVA, 11/0.433 KV Distribution Transformer

2

-

-

... More
Supply installation testing & Commissioning of star rated Copper wound distribution Transformer ( All the distribution transformer must be star rated as per notification of (BEE) ministry of power, Goverenment of India) of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cable box & LT cable boxes, Off -LTC (+5% to - 10% @ 2.5%) temperature rise of 40 degree C in oil / 45 degree C in winding , ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953 , Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, CTL testing charges & Inspection charges shall be reimbursed by the department to the contractor as per actual expenditure. All as per pre approved by Engineer in charge.

-

-

-

... More
315KVA, 11/0.433 KV Distribution Transformer

2

-

-

... More
415 V, 10KA/1sec, Al busbar, 3phase 4wire LT Aux. Panel. Wall mounted. Enclosure shall be CRCA sheet, 1.6mm for non load bearing area and 2mm for load bearing area. Panel shall be compertmentalized only. Incomer= 200A TPN MCCB 1no. Outgoing feeder= 32A TPN MCB 6nos, 16A SPN MCB 6nos. Considering all metering and protection. Paint shall be as per IS 5.

2

-

-

... More
415V LT PCC at clear water pumping station

-

-

-

... More
415 V, 31.5KA/1sec, Al busbar, 3phase 4wire LT PMCC. Floor mounted. Enclosure shall be CRCA sheet, 2mm for non load bearing area and 2.5mm for load bearing area. Panel shall be compertmentalized only. Incomer= 400A TPN MCCB 2nos and buscoupler 1no in same rating, Outgoing feeder= suitable for 37KW (star/delta) motor feeder 4nos, 100A TPN MCCB. Considering all metering and protection. 2NO+2NC to be consider in each feeder for SCADA monitoring / control. Paint shall be as per IS 5. For improvment of Power factor, 50KVAR (5:5:10:10:20) capacitor to be consider including necessary breaker and all.

1

-

-

... More
APFC Panel SITC of Automatic power factor correction panel with 80 kVAR Capacitor bank comprising with APFC relay, capacitor banks,contator,indicating lamp, power factor meter, free standing made of sheet steel enclosed, aluminium bus bar, earthing pads, complete with power & control wiring and suitable to improve the power factor of the system up to 0.98 lag.

2

-

-

... More
APFC Panel SITC of Automatic power factor correction panel with 50 kVAR Capacitor bank comprising with APFC relay, capacitor banks,contator,indicating lamp, power factor meter, free standing made of sheet steel enclosed, aluminium bus bar, earthing pads, complete with power & control wiring and suitable to improve the power factor of the system up to 0.98 lag.

2

-

-

... More
Supply and delivery of floor mounted type FCMA Air/ Oil Cooled soft starter 44 KW suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button.

3

-

-

... More
Supply and delivery of floor mounted type FCMA Air/ Oil Cooled soft starter 46.03 KW suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button.

3

-

-

... More
SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of 110 V DC

2

-

-

... More
SITC of Local Push Button station fabricated with 16 SWG CRCA sheet, painted with polyster Powder coated finish after chemical treatment with Following items and accessories:- (i)Shrouded Type push button with 2 NO Contacts element for Start/forward-reverse. (ii) Lockable Mushroom head type push buuton with 2 NC Contact element. (iii) 2.5 Sqmm clipon type terminals as requried with 20% spares. (iv) 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. Local Push Button Station

7

-

-

... More
Providing & Laying XLPE insulated IS:7098/II/85 of approved make H.T.cable for working voltage 11 K.V.Earthed with Stranded Compacted Circular Aluminium Conductor, Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated, Insulation Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanised flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable direct in ground including excavation of 30cmx100cm size trench, 25cm layer of river sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size.

-

-

-

... More
11 kV 3C-185 AL XPLE cable for HT Panel

350

-

-

... More
1.1 kV 3.5C-300 AL XLPE cable

200

-

-

... More
1.1 kV 3.5C-50 AL XLPE cable for Motors

350

-

-

... More
1.1Kv 4Cx10sqmm, AL, XLPE

170

-

-

... More
4Cx16sqmm, AL, 415V, 1.1 kV

200

-

-

... More
1.1 kV 3C-6 AL XLPE cable

95

-

-

... More
1.1 kV 3C-2.5 CU XLPE cable

320

-

-

... More
1.1 kV 10C-2.5 CU XLPE cable

365

-

-

... More
Cable termination

-

-

-

... More
11 kV 3C-185 AL XPLE cable(Indoor)

8

-

-

... More
11 kV 3C-185 AL XPLE cable(Outdoor)

8

-

-

... More
1.1 kV 3.5C-300 AL XLPE cable

14

-

-

... More
1.1 kV 3C-50 AL XLPE cable

16

-

-

... More
1.1 kV 4Cx16sqmm, AL XLPE Cable

25

-

-

... More
1.1 kV 3C-6 AL XLPE cable

10

-

-

... More
1.1 kV 3C-2.5 CU XLPE cable (19 mm)

36

-

-

... More
1.1 kV 10C-2.5 CU XLPE cable (22 mm)

50

-

-

... More
Supply, Fabricating & installing following sizes of perforated cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with suspenders and including painting as required. (Hot Dipped Galvanized)

-

-

-

... More
300mm x 50mm x 1.6mm

225

-

-

... More
Pipe Earthing as per IS:3043 with perforated 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300 mm and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance as required.

25

-

-

... More
50mm x 6mm G.I. Strip

270

-

-

... More
25mm x6mm G.I. Strip

300

-

-

... More
10 SWG G.I. Wire

280

-

-

... More
P & F lightning conductor finial made out of 25 mm dia.,300 mm long G.I. tube having single prong at top with 85 mm dia., 3 m thick G.I.base plate including holes etc. complete as required.

3

-

-

... More
P & F G.I. tape 20mm x 3 mm on parapet or surface of wall in vertical/horizontal run as required.

160

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required

12

-

-

... More
LED street light fixture with 100 watt luminaries, IP65 protected.

20

-

-

... More
36/40W LED Light 1’x4’ with acrylic/ prismatic front cover (Recessed mounting)

25

-

-

... More
LED Down Light 18/20W (Surface Type)

50

-

-

... More
100 W Street Lighting Fixtures with pressure die cast Aluminium housing.

6

-

-

... More
Supply and erection of Octagonal pole of following length and dimension as per table-3 with base plate on the cement concrete foundation of M-15 /M-20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS 1367 P III ). The pole shall be made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. The pole shall have a weatherproof flush door and locking arrangements. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning. The pole shall be completed with overhangs, Junction Box, two nos. pipes for cable entry and outgoing, wires up to lighting Fixtures.

-

-

-

... More
7 Mtr. Octagonal pole with 1m Single Arm Bracket suitable for 70mm top

18

-

-

... More
Miscellaneous Items

-

-

-

... More
P & F double ball bearing capacitor start ceiling fan of approved make complete with regulator and other accessories as required. (for estimation purpose only)

-

-

-

... More
1400 mm sweep

2

-

-

... More
Rubber Mats for instalation in front of HT Panels

19

-

-

... More
Rubber Mats for instalation in front of LT Panels

19

-

-

... More
SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emission norms) 315 KVA DG set

1

-

-

... More
SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emission norms) 200 KVA DG set

1

-

-

... More
WATER TREATMENT PLANT

-

-

-

... More
Designing (aesthetically ), providing constructing and commissioning Conventional Water Treatment Plant consisting of all Civil, Mechanical and Electrical works including cost of providing and applying epoxy paint to inside surface of water retaining structures in contact with chlorine and providing antitermite treatment to entire structure below ground level, mechanical and electrical components of various sub-works as given below, including necessary hydraulic testing, structural testing, equipment testing and trial run for a period of 3 months, etc. complete as directed by Engineer-in-charge (turn-key job).

-

-

-

... More
Aeration Fountain- Plant are a not less than 0.625 square metre per MLD

-

-

-

... More
Ventury Flume - With necessary devices, consisting of simple mechanical indicator. (Pedestal type gauge)

-

-

-

... More
Flash Mixer-Rapid mixing device, detention time 60 seconds to give velocity gradient 300 to 400 sec -1, vane mixer type conforming to I.S. 7090 of 1985.

-

-

-

... More
Flocculator – Conforming to I.S.7208-1974 (Type-C) with detention period of 30 minutes.

-

-

-

... More
Clarifier - Horizontal flow circular tank, detention period 2-5 hours, overflow rate 30 cubic metre per square metre per day (to be specified), Weir loading not more than 300 cubic metre per metre per day, with mechanical sludge scraper conforming to I.S. No. 10313-1982. with necessary inlet arrangements.

-

-

-

... More
Rapid Sand Filter sand Filter House-Filter designed for filteration rate of 5,000 litres per square metre per hour, minimum 2 beds for plant upto 10 MLD, for larger plants as specified, filters to be located in filter house with roof slab, pipe gallery and platform minimum 5.5 metre in width with constant rate filtration or declining rate filtration.

-

-

-

... More
FilterSand-Effective size 0.45 to 0.70mm, uniformity coefficient not more than 1.7, nor less than 1.3, depth of water over sand 0.75M, free board 50cm, gravel 0.45M in depth, sand and gravel conforming to I.S. 8491 (i)-77, back wash by air wash, standard appurtenances (to be specified), rate of flow controller, filter gauge, sand expansion gauge, etc.

-

-

-

... More
Wash Water Tank-Capacity to be specified and suitable to supply water to wash specified number of filter beds at a time 12 minutes @ 600 lit/sqm/min. under a head of 12 m at under drain.

-

-

-

... More
Wash Water Pumps- Capacity to fill water tank in 1 hour with 100% standby.

-

-

-

... More
Air Blowers-Capable of delivering 600 LMP per square metre of free air, of filter area at 0.4kg / sq.cm at the under drains (100% stand by) for period of 5 min.

-

-

-

... More
Chemical House in Two Storeys

-

-

-

... More
Ground floor to accommodate 7 days' alum requirement and sundry storage. (Minimum 4 m height)

-

-

-

... More
First floor to accommodate alum and lime tanks. Chain pully block etc. (min. 5 m height)

-

-

-

... More
Solution tanks-Minimum 3 tanks (one for preparation, second for dosing and third as stand by), each tank capable of giving 8 hours maximum dose without interruption, minimum free board 0.30M, trays for dissolving, level indicator, mechanical agitation devices, solution feed and drain lines, solution feed device (constant head device, strength of solution upto 10% only) conforming to I.S. 9222 Part-I 1979.

-

-

-

... More
Pure Water Sump and Pump House.

-

-

-

... More
Capacity of sump – One hour of designed flow.

-

-

-

... More
Pump House- Pump house of required size over the sump or by the side.

-

-

-

... More
Store House-Suitable for alum storage of three months and 7 days temporary storage, 7 days TCL requirement in mansoon with 20% extra capacity for other sundry articles.

-

-

-

... More
Vacuum feed type Chlorinators- Make tobe approved by MJP.

-

-

-

... More
Conforming to I.S. 10533 - A Part-II 1983

-

-

-

... More
Rate for withdrawal

-

-

-

... More
Temperature Degree 'C' 10 /15 /20/ 27 & Above

-

-

-

... More
Chlorinator equipment and container room to conform to I.S. 10553 Part-I 1983.

-

-

-

... More
100% standby shall be provided.

-

-

-

... More
By pass arrangements - C.I. or M.S. pipes.

-

-

-

... More
Disposal of waste from WTP : Safe disposal arrangement to nearby nalla including cost of pipe.

-

-

-

... More
For WTP of capacity 30 mld and more additional arrangement for backwash water recycle shall be provided , including sump, pumping machinary, rising main etc. complete.

-

-

-

... More
Drainage arrangements To decant all units of WTP with CI pipes upto boundary of each unit and further extension with RCC pipes to nearby nalla.

-

-

-

... More
Electrical installation – Both internal and external including entire plant area.

-

-

-

... More
Laboratory equipment –As per requirement (to be specified during tendering).

-

-

-

... More
Sanitary blocks – Carpet area -15 square metre minimum upto 25 Mld and 25 square metre above 25 Mld.

-

-

-

... More
Administrative block and internal road-To accommodate office room, chlorine room, laboratory room, panel board room, blower room etc. and WBM road to connect all units from main gate of plot.

-

-

-

... More
Rates given below are inclusive of up lift pressure if any and dewatering during entire work.

-

-

-

... More
All pipes conduits channel with 20% overloading.

-

-

-

... More
These rates are applicable for seismic zones 2, 3 and 4.

-

-

-

... More
All RCC structures shall be constructed in M-300

-

-

-

... More
Cost of 16.5 MLD WTP

1

-

-

... More
ELEVATED SERVICE RESERVOIR

-

-

-

... More
Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 metres centre to centre for ESR having capacity upto 500 cum and not more than 6 m c/c for ESRs having capacity above 500 Cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling disposing off the surplus stuff within a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout,overflow and bypass arrangements as per departmental design, providing and fixing accessories such as M.S. ladder, C.I. manhole frame and covers, water level indicators, lightening conductor, G.I. pipe railing around walk way and top slab, providing spiral stair case from ground level to roof level, M.S. grill gate of 2 M height with locking arrangement of approved design, B.B.masonry chambers for all valves, ventilating shafts, providing and applying three coats of cement paint tothe structure including roof slab, epoxy painting to internal surface and antitermite treatment for underground parts of the structure and giving satisfactory water tightness test as per I.S. code. The job to include painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in-Charge.

-

-

-

... More
The design of the structure be in accordance with relevant I.S. specification (I.S. 3370 - 1965 or revised.)

-

-

-

... More
The design shall satisfy the stipulations as per I.S. 1893 - 1984 and I.S. 13920 / 1993 for seismic force and I.S. - 11682 / 1985 for R.C.C. staging of overhead tanks.

-

-

-

... More
For design having more than 6 columns, provision of internal bracing is obligatory. External bracings is also obligatory.

-

-

-

... More
Plain round mild steel bars grade-I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall be used, grade-II mild steel bars will not be allowed.

-

-

-

... More
These rates include providing M.S. ladder for E.S.R.s upto 2 lakh litres capacity and providing spiral staircase for E.S.R. above 2 lakh litres capacity

-

-

-

... More
Staging shall have to be designed with stresses of M-200 concrete for ESR. However all RCC construction should be done in M-300

-

-

-

... More
These rates are including the cost of uplift pressure if any and entire dewatering during execution. In case of water logging area where water is stretch at shallow depth, extra provision of dewatering shall be made as per site condition.

-

-

-

... More
75% part rate shall be payable for reinforcement concrete and plastering items of containers of E.S.R. till satisfactory hydraulic testing for water tightness is given; and till that work shall be treated as incomplete.

-

-

-

... More
The rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet, washout, overflow and bypass arrangement. The scope of work, however, includes cost of erecting, laying and jointing of pipes and valves including cost of jointing materials upto 5 M beyond outer face of outermost column

-

-

-

... More
For ESR upto 500 cum capacity C.I. double flanged pipes upto 300 mm dia shall be provided and C.I. specials shall be used. For ESR above 500 cum capacity C.I./M.S. pipe assembly with minimum 8 mm thickness upto 500 mm dia and minimum 10 mm thickness above 500 mm dia can be used with proper anti-corrosive epoxy treatment from inside and outside.

-

-

-

... More
Below mentioned rates are for foundations with individual footing with bearing capacity of 20 tonnes per square metre. For raft foundations, these rates shall be increased by 7.5% where safe bearing capacity (SBC) is 5 MT per sqm and by 5% where SBC is more than 5 MT/sqm and upto 10 MT/sqm. This % of 5% or 7.5% is applicable for estimation of amount of lumpsum item of ESR. For extra item due to change from individual foundation to raft, actual increase in concrete and steel be paid as per relevant DSR item.

-

-

-

... More
Estimate of Elevated Service Reservoir - ESR - 1000 KL at Old Nagar Parishad, Staging - 20 m

1

-

-

... More
Estimate of Elevated Service Reservoir - ESR - 500 KL at PHED Campus, Staging - 22 m

1

-

-

... More
Estimate of Elevated Service Reservoir - ESR - 1000 KL at Nigani , Staging - 15 m

1

-

-

... More
Estimate of Elevated Service Reservoir - ESR - 950 KL at Madhavtoli, Staging - 14 m

1

-

-

... More
RAILWAY/NH CROSSING

-

-

-

... More
Excavating of driving pit and receiving pit of size 3.00m (length) x 3.50m (breadth), depth upto 5m in all soil strata including shoring and strutting using 6mm tk MS Plate of size 3.50m x 3.50m usable for 15 operations and providing 16mm thickness MS plate of size 3.00m x 3.50m with 100mm x100mm x 12mm angles of 4m length for holding the MS plates for Thrust arrangements to receive the impacts during pushing operation of encasing pipe. Lowering the following size of MS encasing pipe by using Contractor’s crane and machineries and jointing MS pipes by welding, across the National Highways/State Highways/ Railways/Canal crossing etc and driving the horizontal bore by pushing / jacking method (trenchless technology method) using contractor’s machineries such as cranes, jacks, jacking materials, generator, welding machineries, compressor, jack hammer and other equipments etc. without interfering and causing any hindrance to the movement of traffic or any other vehicles, without any disturbances to the railway/road/canal formation etc. including bailing / pumping of water where ever necessary without affecting any installation like water supply pipeline/telephone cable, electric cables etc. passing nearby area and scooping the earth inside the pipes and pit and depositing the surplus earth in a convenient place and leveling the site after completion of entire work as directed by TWAD Engineers.

-

-

-

... More
For 400mm dia DI pipe - 750 mm dia casing pipe

45

-

-

... More
For 100mm dia DI pipe - 350 mm dia casing pipe

45

-

-

... More
Manufacturing, providing and supplying spirally welded / ERW/ SAW / fabricated M. S. pipes (Commercial Quality) including procurements of plates, gas cutting to required size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming ‘V’ edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, unloading, stacking, excluding GST levied by GOI & GOM in all respect etc. complete as per IS - 3589 and IS-5504 as applicable as per specifications (No negative tolerance in thickness is permissible).

-

-

-

... More
750 mm ID 10 mm thick

45

-

-

... More
300 mm dia casing pipe

200

-

-

... More
500 mm dia casing pipe

25

-

-

... More
400 mm dia casing pipe

30

-

-

... More
350 mm ID 8 mm thick

45

-

-

... More
Providing and applying primer first coat of intertol 49 W emaline 05/ 58 pipe coat or any other equivalent approved paint to the internal surface of pipeline at site, etc. complete.

-

-

-

... More
FIRST COAT

1093.42

-

-

... More
SECOND COAT

1093.42

-

-

... More
RIVER/NALA CROSSING

-

-

-

... More
Earth work excavation for Footings - E/W in excavation of toe drain and heel trenches as per designed section in ordinary rock or soft rock (where blasting is not needed) (Vide classificationof soil item C) with disposal of the spoil 50 m away from the toe of the drain country side with initial lead of 100 m and initial lift of 1.5 m as per specification and direction of E/I.

411.43

-

-

... More
PCC for Footings - Providing PCC for M-150 with nominal mix of (1:3:6) in foundation with approved quality of stone metal grade III (50 mm to 25 mm) size clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I

27.43

-

-

... More
Providing and laying in position ready mix or site batched design mix cement concrete for RCC work; using coarse aggregate and fine aggregate derived from natural sources,Portland Pozzolana/ Ordinary Portland/ Portland Slag Cement, admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering.shuttering, finishing and reinforcement as per direction of the engineer-in-charge.

-

-

-

... More
M-30 for Foundation

164.57

-

-

... More
M-30 for Columns

102.86

-

-

... More
Centering and Shuttering including strutting, propping etc. and removal of form for..

-

-

-

... More
For PCC

54.86

-

-

... More
For Foundations

329.14

-

-

... More
For Columns

822.86

-

-

... More
Beams below the deck slab (Plastering) - Providing Cement Deep Ruled Pointing (1:3) with clean coarse sand with F. M 1.5 including screening, curing all leads and lifts of water, scaffolding taxes and royalty all complete as per all specification and direction of E/I.

225

-

-

... More
Slab (Painting) -Providing two snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper , scaffolding , curing and taxes all complete as per building specification and direction of E/I.

600

-

-

... More
Pushing of M.S. pipe of following dia for road crossing and raiway crossing by push through method in all types of strata by using hydraulic jack and drilling machine of required diameter below 3.0 m depth including lowering, laying, jointing of M.S. casting pipe including cost of labour, fuel and material, required welding machinery, tripod, chain pulley block, crane, blower,etc., transportation and dewatering etc. complete as directed by Engineer in charge but excluding cost of M.S. pipe.

-

-

-

... More
a) 200 mm to 499 mm dia MS pipe

30

-

-

... More
b) 500 mm to 1000 mm dia MS pipe

225

-

-

... More
HOUSE SERVICE CONNECTION

-

-

-

... More
Providing and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour , UPVC/MDPE Pipe of required length with or without Road crossing as described below, including cost of specials like Saddle/Clamp Saddle of suitable material, and diameter suitable for Distribution main, 15mm /20mm/ 25mm respective Dia Heavy duty Brass/Polyprophylyne(Twin Jacketed ) Ferrule , Male and Female thread adapter Elbow, Bends,couplers ,Tees, Clamps of suitable material and sundry materials as per requirment, including providing and fixing medium duty 15.mm brass bib tap, GI casing pipe of suitable diameter of 32mm/ 40mm/ 50mm respectively of required length for Road crossing, including requird labour for excavation in all types of strata up to the depth of 0.75m or as per site requirement,all types of plumbing fittings, refilling , Closing the water supply in that area, dewatering, hydraulic testing and restarting the water supply ,transportation of material etc. complete as directed by Engineer in charge.

-

-

-

... More
A) Household Connection without water meter (Compression Saddle+ISI Mark Ferrul) for HDPE & PVC pipe

-

-

-

... More
For MDPE/UPVC Pipe Service Connection on Disribution main

-

-

-

... More
(With Road Crossing) For 15 mm Service connection

14300

-

-

... More
Providing, installing and giving satisfactorily field testing of domestic water meter, horizontal inferential type multijet type with magnetic drive and dry dial suitable for 50 degree temperature duly sealed against tampering complete with couplings at both ends and conforming to class B as per IS 779/1994 (VI revision) with ISI mark along with manufacturer's test certificates and guarantee certificates including cost of all labour and materials. 20 mm dia

14300

-

-

... More
Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue/black. Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed byengineer in charge

14300

-

-

... More
BOUNDARY WALL

-

-

-

... More
Excavation for structures (earthwork in excavation of foundation of structures as per drawing and technical specifications, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilizing the remaining earth locally for roadwork.)

176.32

-

-

... More
Removal of unserviceable soil with disposal up to 1000 m (removal of unserviceable soil including excavation, loading and disposal up to 1000 m lead but excluding replacement by suitable soil which shall be paid separately as per clause 305.

111.36

-

-

... More
Providing PCC M-150 nominal mix of (1:2:4) in foundation with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specifications and direction of Engineer-in-charge.

34.03

-

-

... More
Providing R.C.C. M-200 with nominal mis of (1:1:5:3) in foundation and plinth with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing but excluding the cost of reinforcement, taxes and royality all complete, as per building specification and direction of E/I.

81.97

-

-

... More
Centering and Shuttering including strutting, propping etc. and removal of form work.

-

-

-

... More
PCC

58.78

-

-

... More
PCC

171.68

-

-

... More
Column Footing

139.2

-

-

... More
Columns

326.66

-

-

... More
Tie Beams

312.43

-

-

... More
Coping

92.8

-

-

... More
Providing Tor steel reinforcement of 10 mm, 12 mm & 16 mm dia bars as per approved design and drawings including carriage of bars to work site. Including cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. (a) 10 mm (TMT coil Fe 500)

8.2

-

-

... More
Providing designation 75A brickwork in C.M. (1:6) in superstructure with approved quality of clear coarse sand of FM 2 to 2.5 including providing 10 mm thick mortar joints cost of screening, materials, scaffolding, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.

-

-

-

... More
Wall

98.99

-

-

... More
Providing 12 mm thick cement plaster (1:6) with clean coarse sand of FM 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I.

870.78

-

-

... More
Providing 2 coat of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing, and taxes all complete as per building specification and direction of E/I.

1113.6

-

-

... More
Providing and fixing concertina coil fencing with punched tapeconcertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge.

464

-

-

... More
Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5 mm, 10 cm long, forked at end 60cm apart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. complete

2301.44

-

-

... More
MS square bar 10 mm

27.84

-

-

... More
Supplying, fitting and fixing M. S. grill gate with M. S. grills made of 20 x 6 mm M. S. flats or 16 mm M. S. square bars fitted on 25 x 25 x6 mm M.S. angle frame -do- (When steel is not supplied by the deptt.)

180.65

-

-

... More
SCADA

-

-

-

... More
SCADA server (RackMountable Server) -Redundant configuration

2

-

-

... More
Historian server (Rack Mountable Server)

1

-

-

... More
Rack cabinet inclusive of Rack monitoring system complete with 22"LCD Monitor & computer

2

-

-

... More
Engineering & Operating stations at Each ESR with 32" LED Monitor loaded with SCADA software +latest windows OS+MS Office

5

-

-

... More
LED Video display system -65"

2

-

-

... More
Multifunction Laser printers (Scan,copy, & PrintA3 & A4 size)

1

-

-

... More
Printer-(Online & Offline Functionality) at each ESR Location

5

-

-

... More
PLC - WTP

-

-

-

... More
PLC Panel inclusive of Hot standby (redundant )Programmable Logical Controller (PLC) CPU,redundant power supply ,redundant communication interface, input/output modules with duplex I/Os for critical I/O's,managed ethernet switches(24 port),to be located in the administration building .Required RIO panels at various locations in the plant.The system shall be designed to interface with the centralized SCADA server as per bid specifications.

1

-

-

... More
PLC software - Programming software Designing, Supplying, Installing, commissioning & testing of PLC based control monitoring and communication software at WTP

1

-

-

... More
Filter bed Control panels with 20" HMI:- Designing, Supplying, Installing, commissioning & testing of PLC Panel with HMI including PLC with CPU & Power supply unit, power supply cable, interfacing cards, interfacing cables,k wireless modules with 25% extra quantity of all accessories.

5

-

-

... More
24 port Managed EThernet switch for WTP control system

2

-

-

... More
INTAKE Well-Jackwell Location:- PLC Panel inclusive of Standalone Programmable Logical Controller (PLC) CPU,redundant power supply ,16" color touch screen HMI,redundant communication interface, input/output modules,managed ethernet switches(8 port),.The system shall be designed to interface with the centralized SCADA server over wireless GPRS based communication network.

1

-

-

... More
Field Instruments @ WTP,Intake well/Jackwell

-

-

-

... More
Ultrasonic level transmitter Designing, Supplying, Installing, commissioning & testing of Ultrasonic type level transmitter CE marked Interfacing with PLC panel including mounting arrangement. Output-4-20 mA Power supply - 24V DC ext. Display - 4" LED Range- 0 to 15 mtrs Accuracy - +/- 0.25% of Full Scale or better Enclosure- IP 67

6

-

-

... More
Radar type- level transmitter Designing, Supplying, Installing, commissioning & testing of Radar level transmitter CE marked with following technical parameters at INTAKE WELL/JACKWELL Interfacing with PLC panel including mounting arrangement. Output-4-20 mA Power supply - 24V DC ext. Display - 4" LED Range- 0 to …………... mtrs Accuracy - +/- 0.25% of Full Scale or better Enclosure- IP 67 Mounting - On PLC panel

1

-

-

... More
Open Channel Flow Transmitter for measurement of flow with totalizer:- Design, Supply, Installation, Testing & calibration of open channel type ultrasonic flow transmitter CE marked with following technical parameters Interfacing with PLC panel including mounting arrangement. Range- 0 - 5 mtrs, Output-4-2o mA, Power Supply - 24V DC ext. Display - 4" LED Accuracy - +/- 0.25% of Full Scale or better Enclosure- IP68

4

-

-

... More
Providing, installation, testing and commissioning of Level Switch ( Conductivity) Conductivity Probes: (i) Rigid for lengths of up to 3 meters (ii) Flexible for lengths above 3 meters (Rigid probes preferred), Probe insulation: Teflon, Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminum

6

-

-

... More
Pressure Transmitter :- Designing, Supplying, Installing, commissioning & testing of pressure transmitter CE markd with following technical parameters Interfacing with PLC panel including mounting arrangement. Output 4-20 mA Power supply - 24V DC ext. Display - 4" LED Accuracy - +/- 0.1 % of full scale or better Enclosure- IP 67

14

-

-

... More
Pressure Guages at outlet line:- Providing, erecting Pressure gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia G.I. Pipe. Pressure gauge shall be installed as directed. Pressure gauge (150 mm dia)

28

-

-

... More
pH Analyser Design, Supply, Installation, Testing of pH Analyser Interfacing with PLC panel including Mounting arrangement. Range : 0‐14 , pH Accuracy : Better than 0.5% of full scale Supply Voltage : 24V dc, Output : 4‐20 mA, As per IEC 61000-6-2 & IEC 61000-6-3

2

-

-

... More
Turbidity Analyser Design, Supply, Installation, Commissioning & Testing of Turbidity Analyser Interfacing with PLC panel. Turbidity Analyser shall comprises of 3 components i.e. sensors,signal distributor and transmitter with indicator with 2 outputs, 1 to PLC & another to local display including Mounting arrangement. Overall Range : 0 ‐ 100 NTU Accuracy : +/ ‐ 0.02 NTU Supply Voltage : 230 V ac, Output : 4 ‐ 20 mA

2

-

-

... More
Residual chlorine analyser Design, Supply, Installation,Testing of Residual chlorine analyser / meter must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors,flow through assembly and transmitter with indicator and gives 2 outputs one to Local display & other to PLC including Mounting arrangement. Overall Range : 0 ‐ 8 mg/l (ppm), Accuracy : 2% of full scale Supply Voltage : 230 V ac, Output : 4 ‐ 20 mA, Membrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must be provided to avoid maintenance. IP 65 Nema 4 housing protection class requird.

1

-

-

... More
Sludge blanket monitor

2

-

-

... More
Pressure Switch (PS) with required manifold, and all other required accessories

8

-

-

... More
Temperature Transmitter (RTD) + Thermowell

-

-

-

... More
At common Blower Discharge

1

-

-

... More
Temperature indicating transmitters at discharge of each blower

4

-

-

... More
Temperature indicators at section of each blower discharge

4

-

-

... More
Junction Boxes and Field Enclosures

-

-

-

... More
Field Junction Boxes

15

-

-

... More
Local Control Panels

15

-

-

... More
Surge Protection Devices

-

-

-

... More
Surge Protection Devices

8

-

-

... More
Lab equipment as per bid specifications for WTP

-

-

-

... More
Armoured Instrumentation Cables,with instrumentation earthing for the plant.

7000

-

-

... More
Earth flat 25x6 mm

2500

-

-

... More
Earthing pits copper plate

12

-

-

... More
Supply and Installation hot dip GI perforated cable tray with cover along with required angle supports, with coupler plates, Anchor bolts and nuts etc complete and the tray should be fitted on the wall / Ceiling etc. complete. For all instrummnetaiton cables

1000

-

-

... More
Mandtory Spares

-

-

-

... More
Spares to be provided for the control system on a minimum during commissioning.

-

-

-

... More
Central Processing Unit(CPU)

1

-

-

... More
Digital Input Module

2

-

-

... More
Digital Output Module

2

-

-

... More
Analog Input Module

2

-

-

... More
Managed ethernet switch(24 Port)

1

-

-

... More
GPRS wireless Communicaiton Module

2

-

-

... More
Software

-

-

-

... More
SCADA software with 25K tags for 8.5 MLD WTP + monitoring of ESR data with water quality+ water distribution network(DMA zone) and real time integration with Google earth software for real time view and analysis.

2

-

-

... More
SCADA software with 5k tags for monitoring of ESR data with water quality+ water distribution network(DMA zone)

5

-

-

... More
Google earth license software and integration with SCADA server in real time

1

-

-

... More
Historian software with 25K tags

1

-

-

... More
Ancillaries to be provided

-

-

-

... More
GPRS Wireless communication Module to receive and transmit data from various remote locations(ESR+Jackwell) to WTP control center

6

-

-

... More
GPRS Wireless communication Module (in redundant configuration(1+1)) to receive and transmit data from various remote locations at the CSC Sewerage SCADA server

2

-

-

... More
Routers for Internet access in the control center area+ Control center Operating area

2

-

-

... More
EPABX system for Control center

1

-

-

... More
Hi speed broadband leased line to contol center for receiving data from various remote stations

1

-

-

... More
Hardware based Firewall & software firewalls with complete cyber security solution for the centralized SCADA center.Fully scalable without any limitations on the number of clients

1

-

-

... More
Management Information System -MIS Software

-

-

-

... More
CCTV system with night mode view enabled cameras for the control center-Inclusive of indoor cameras(2 Nos) + Outdoor (5 Nos) inclusive of CCTV control system,data archiving system,all related accessories,etc.

7

-

-

... More
UPS System - 15 KVA ,Three phase,415V,50Hz,Standalone,Online,microprocessor based UPS System with SMF batteries for 60 minutes backup with accessories.

1

-

-

... More
Supply, Installation, Testing and Commission of 1 KVA UPS with battery backup of 60 Mins on Full Load-UPS with AC Distribution Board

1

-

-

... More
Supply, Installation, Testing and Commission of Ultrasonic Level Transmitter ( 0- 10 m) at ESR and Interfacing with PLC system including all required Mounting accessories required.

5

-

-

... More
Automation Component

-

-

-

... More
Supply, Installation, Testing and Commission of Integration panel at each ESR comprising of Standalone Programmable Logic Controller(PLC)/RTU with 16" touch color HMI,power supply modules,PLC panel to house the above components along with GPRS communication modules

5

-

-

... More
IP-65 rated enclosures for housing LIT,FIT.,wigth mounting accessories

5

-

-

... More
ESR- Supply, Installation, Testing and Commission of 1 KVA UPS with battery backup of 60 Mins on Full Load-UPS with AC Distribution Board

5

-

-

... More
Supply, Installation, Testing and Commission of Electromagnetic flowmeter to measure real time flow in the water distribution network of the following sizes,inclusive of all required accessories and installation,testing & commissioning:

-

-

-

... More
100 MM dia

6

-

-

... More
150 MM dia

5

-

-

... More
200 MM Dia

21

-

-

... More
250 MM Dia

9

-

-

... More
300 mm Dia

1

-

-

... More
350 MM Dia

6

-

-

... More
400 MM Dia

6

-

-

... More
THRUST BLOCK

-

-

-

... More
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I.

1089.29

-

-

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming & watering in layers not exceeding 150 mm thick with all leads and lifts including cost of all materials, labour, royalty & taxes all complete as per building specification & direction of E/I. (mode of measurement compacted volume)

16.13

-

-

... More
Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.

215.06

-

-

... More
For Thrust Block :- Providing RCC M-150 with nominal mix of (1:2:4) in foundation and plinth with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing (but excluding the cost of reinforcement), taxes and royalty all complete, as per building specification and direction E/I

597.01

-

-

... More
Carriage of material

-

-

-

... More
Bricks

60.24

-

-

... More
Sand

10556

-

-

... More
Chips

16839.89

-

-

... More
Cement

7946.87

-

-

... More
UTILITY SHIFTING

-

-

-

... More
Removal of telephone / Electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately as per MoRT&H specification clause 202.

110

-

-

... More
Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer.

-

-

-

... More
Cement Concrete Grade M-15 and above and PCC blocks

179.09

-

-

... More
Clearing Grass and Removal of Rubbish (Maximum 150mm) by manual means and disposal at a lead of 50 metres as per MoRT&H specification clause 201.

0.72

-

-

... More
Encasing

460.2

-

-

... More
ENVIRONMRNTAL MITIGATION PLAN

-

-

-

... More
Plantation at river bank Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/ sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year.

1500

-

-

... More
Air quality monitoring For parameters: PM10 µg/m3, SO2, NOx, CO approved laboratory and submission of report complete in all respect. Calibrated Equipment’s (In Every 2 months: weir location, batching plant, haul road, construction/labour camp)

132

-

-

... More
Noise levels monitoring To identify sources of noise, Noise due to traffic/transportation of vehicles, Noise due to heavy equipment operations, Duration and variations in noise over time etc., the equivalent, noise levels should be monitored (Lday and Lnight in Leq dBA) from NABL approved laboratory and submission of report complete in all respect. (In Every 2 months: weir location, batching plant, haul road, construction/labour camp)

192

-

-

... More
Surface water monitoring PH, TDS Taste & Odour, Turbidity, Magnesium, Total hardness, Total alkalinity, chloride, sulphate, nitrate, fluoride, calcium, Iron, pesticide, manganese, copper, Arsenic, Cadmium, Cyanides, Lead, Selenium, mercury. IS:10400-2012 (In every 2 months 3 location: Labour camp, U/s weir, D/s weir)

144

-

-

... More
Operation and Maintenance

-

-

-

... More
Surface water monitoring for total coliform, fecal coliform, IS10500 and as per CPCB criteria(Quarterly 3 Locations

30

-

-

... More
Surface water monitoring PH, TDS Taste & Odour, Turbidity, Magnesium, Total hardness, Total alkalinity, chloride, sulphate, nitrate, fluoride, calcium, Iron, pesticide, manganese, copper, Arsenic, Cadmium, Cyanides, Lead, Selenium, Mercury. IS: 10500: 2012 (Quarterly 2 Locations)

100

-

-

... More
Capacity Building

-

-

-

... More
Training on EMP implementation (50 persons for 1 days)

8

-

-

... More
Contractors Orientation to Workers on EMP implementation (50 persons for 3 days)

8

-

-

... More
OPERATION AND MAINTANENCE

-

-

-

... More
Carrying out operation and maintanence of work for a period of 5 years includng cost of all supervisory staff, materials, chemeicals, equipments, consumables including sludge analysis and dispposal establishing manitanence of complete instrumentation control and automation system with manpower to operate the Intake, WTP, ESRs (24x x 7)with data transmission cost to centralized SCADA centre , comprehensive manitanence of field instrumentation, control and automation at all location etc complete as per direction by Engineer in charge. (The bid gwill be rejected if bidder has not quoted O&M cost in below rows.)

-

-

-

... More
Operation and Maintenance for 1st year

4562500

-

-

... More
Operation and Maintenance for 2nd year

4659833.33

-

-

... More
Operation and Maintenance for 3rdyear

4757167.67

-

-

... More
Operation and Maintenance for 4th year

4854500

-

-

... More
Operation and Maintenance for 5th year

4951833

-

-

... More
Maximum guaranteed electricity consumption ( please quote quantity in KWH/year for the following rows in column "M". The cost will be used for evaluation)

-

-

-

... More
1st Year

6.25

-

-

... More
2nd Year

6.25

-

-

... More
3rd Year

6.25

-

-

... More
4th Year

6.25

-

-

... More
5th Year

6.25

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.