Urban Development Department Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Urban Development Department - JUIDCO Tender

Eprocure
Opening Date2 Jul 2021
Closing DateCancelled
Tender Amount₹ 23,78,33,300 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Extra rates for quantities of works, executed : In or under water and/or liquid mud, including pumping out water as required.

5669

-

-

... More
5.1.7 Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).

1728

-

-

... More
Chapter II - 2.11, 2.12 & 2.13 Removal & disposal of surplus excavated earth by mechanical transport including loading unloading stacking and spreading at all lift and lead up to 5km to spoil dump approved by local authority.

21382

-

-

... More
Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer In charge (Mode of measurement compacted volume)

50

-

-

... More
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diaMTR.er holes and plugging with cement mortar 1:2 (1 cement : 2 Coarse sand) to match the existing floor With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

2688

-

-

... More
5.3.1.6 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

280

-

-

... More
providing and laying cement concrete in retaining walls, return walls, wall (any thickness) incluuding attached plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc, upto floor five level, excluding the cost of centering, shuttering and finishing:1:11/2:3(1 cement : 11/2 coarse sand (zone III) : 3 graded stone aggregate 20 mm nominal size)

11

-

-

... More
5.3.29.1 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix, and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge.NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately (2) Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacement of OPC as per IS : 456. Uniform blending with cement to be ensured in accordance with clauses 5.2 and 5.2.1 of IS:456 -2000 in the items of BMC and RMC. All works upto plinth level

2286

-

-

... More
5.3.29.2 All works above plinth level upto floor V level

2949

-

-

... More
Add for using extra cement in the items of design mix over and above the specified cement content therein.

2094

-

-

... More
DSR 5.9.1 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete

1028

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

4686

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform

8972

-

-

... More
DSR 5.9.5 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers

4820

-

-

... More
DSR 5.9.6 Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts

3308

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases

354

-

-

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

6500

-

-

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

50

-

-

... More
5.5.4 Providing Tor steel reinforcement of 8mm. Dia rods as per approved -do- TMT Fe 500 (only valid for Tata (Tiscon), SAIL, JSPL, Electosteel Steels Ltd, BOKARO and Vizag (RINL)

94.23

-

-

... More
5.5.5 AProviding Tor steel reinforcement of 10mm, 12mm & 16mm dia bars as per approved -do- TMT, 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL, Electosteel Steels Ltd, BOKARO and Vizag (RINL)

125.64

-

-

... More
above 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL, Electosteel Steels Ltd, BOKARO and Vizag (RINL)

408.33

-

-

... More
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x425"x3") in C.M. (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.

25

-

-

... More
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:4) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.

934

-

-

... More
Providing designation 112mm thick reinforced designation 100A brick work with flyash lime brick (FLAG) in (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.

2642

-

-

... More
Extra for brick work for each consecutive floor above first floor including watering & scaffolding all complete as per direction of E/I

302.3

-

-

... More
Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary

2642

-

-

... More
Supplying, fitting and fixing good quality, well dressed and well seasoned Sal wood work in choukhat in doors, windows, skylights, fanlights and C/W celestial window openings, including wedge over all clamps complete includingapplicationof two coatsof wood preservativeof approved quality on the surface butting walls and lintels all completeas per building specificationand direction of E/I

1

-

-

... More
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with one side teak decorative and another side commercial vennered -do-

12

-

-

... More
Supplying, fitting and fixing 35mm thick solid core type decorative double leaf flush door shutter with one sides teak decorative and another side commercial veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l. MAKE ARCHIDPLY,Green ply, Marino, Century

55

-

-

... More
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).

67

-

-

... More
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).

67

-

-

... More
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :50x12 mm

109

-

-

... More
Providing, fitting and fixing oxidised iron fitting of approved quality and make to door and window all complete as per building specification and direction of E/I necessary screws etc. complete.300 mm sliding door bolt

34

-

-

... More
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.

17

-

-

... More
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineerin-charge.

17

-

-

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper

17

-

-

... More
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

17

-

-

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness

4

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge

24

-

-

... More
Melamine polishing on wood work (one or more coat).

56

-

-

... More
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge. Extruded section profile size 48x40 mm

66.3

-

-

... More
30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge.

79.7

-

-

... More
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately). except bottom. (Door will be commercial ply finish only.)

96

-

-

... More
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately).

19

-

-

... More
Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc., with G.I. beading of appropriate size, made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc., complete all as per direction of Engineer-incharge. With clear fire resistant glass panes 6mm thick of approved brand, having minimum 60 minutes fire resistance

2.4

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

2632.77

-

-

... More
DSR 10.25.2 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

4000

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

6300

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length an jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover

600

-

-

... More
Providing and fixing ball bearing for rolling shutters.

116

-

-

... More
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places."

801

-

-

... More
MR Skylight ( polycarbonate sheets ) : Supply and installation of 5 mm thick clear embossed polycarbonate sheet (sabic india make ) (polycarbonate profile to match with standing seam profile with side laps to be clamped with bare galvalume sheets of 0.55mm (tct) , which can be further seamed with metal roof sheets. Product required is clear embossed with both sides UV stabilizer, having at least 60-80 % transparency, conforming to the relevant IS Code including cutting to shape and size as required including necessary sealants (silicon sealants / butyl sealants for transverse laps). Including all materials, tools & tackles, labour etc. required for completing the work in all respect as per direction of engineer in-charge.

190

-

-

... More
Providing and laying Double charged vitrified floor tiles in different sizes ( thickness to be specified by the manufacture ) with water absorption less than 0.08% and conforming to IS: 15622/ISO 13006 of approved make in all colours and shades laid on 20mm thick cement mortar 1: 4 ( 1 cement : 4 coarse sand ), jointing with grey cement slurry @ 3.3kg / sqm including grouting the joints with white cement and matching pigments etc. complete of tile 600 x 600mm

1892

-

-

... More
Providing and laying 25mm. Thick kotah stone slab flooring of approved size, texture and colour over 19mm thick base of lime morter(1:1:1) (lime putty: surkhi: coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specefication and direction of E/I. (iv) 600x600 mm size.

1138

-

-

... More
Providing and laying 25mm thick kotah stone tiles in risers of steps, skirting and pillars of approves size, texture and colour laid over 12mm, thick cementmortar (1:3) and joined with grey cement slurry mixed with pigment to match the shade of the slab including rubbing to granolithic finish with approved quality -do-

109

-

-

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

151

-

-

... More
Providing and fixing granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab over 0.50 SQM

21

-

-

... More
Providing edge moulding to 18 mm thick marble/granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work

31.6

-

-

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

32

-

-

... More
Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.

21

-

-

... More
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade

5.4

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

174

-

-

... More
Providing and laying 1st quality Ceramic glazed wall tiles thickness to be specified by the manufacturer) in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I.

675

-

-

... More
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/SQM including pointing in white cement complete. 8mm thick Granite of any colour and shade

400.26

-

-

... More
Providing 50mm thick cement concrete flooring (1:2:4 with 20mm to 6mm size grade stone chips finish with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes & royality with all complete as building specification and direction of E/I

419.93

-

-

... More
MR Extra for vaccum dewatering the concrete floors using TREMIX or equivalent over P.C.C layer i/c finishing the top surface to required level/ slope and grade with rough / polish finish using power trowels (both fan & disc) of standard make including curing, cutting of groove of grid size 4m x 4m with, mixing of nonMTR.allic hardening compound (3.0 Kg/SQM of Fosroc or approved make) ,cutting of VDF floor with Diamond Saw System (disposal of debris to be included in the quoted rate)as per specification etc. complete as per specification and drawing. (Maximum thickness of RCC flooring shall be of 150 mm) At all heights / depths and levels.

2135

-

-

... More
Extra for filling grooves with polysulphide 6mm wide, 20mm deep.

2135

-

-

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase

290

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

10

-

-

... More
The entire system of supply of material and installation should be done directly by the manufacturer through in-house team with a guarantee of 10 years against leakages Repairing cracks by cutting and making V-groove in 25x25 mm, with polymer modified mortar using SBR latex, filling the groove with CM(1:3) mixed with polymer 10% by weight of cement Spray apply an average 50mm thick PU foam insulation(U Value= 0.407 W/m2 °k) with a core density as per ASTM D1622 of 45-50 kg/m3 , thermal conductivity of 0.023 W/m.k at 25 degree mean temperature as per ASTM C518/91, compressive strength with rise of 4.2 kg/cm2 as per ASTM D- 1621/94,Tensile strength 5.1 Kg/cm2 as per ASTM D1623/78,Closed cell content, apparent vol,% of 96-98, fire resistance property confirming to class B2 as per DIN 4102. A bitumen filler board of 10 mm thickness for construction joints shall be placed vertically to form a rectangular bay not exceeding 12 sq.mtr. Applying liquid-applied, highly permanent elastic, cold applied and cold curing, one component,based on pure elastomeric hydrophobic polyurethane resins, Solvent based with root resistance properties polyurethane membrane with elongation of 400% as per ASTM D 412,tensile strength of 4 Nsqmm as per ASTM D412,shore hardness(shore A scale) 75 as per ASTM D 2240,adhesion to concrete 2.0 N/mm2 as per ASTM D 903 applied in 2 coats at a total consumption of min. 1.2 Kg./ Sq.Mt Providing & laying 150 GSM geotextile layer.Applying avg 75 mm thick M20 fibrated grade concrete screed including control joints of 3M X 4M size , making angle fillet of 50mmX50mm using M20 grade concrete at the corners. Exposed filler boards shall be cut by mechanical means and filling the groove with Polysulphide Sealant. The width of sealant fill shall not exceed 10mm.( (concrete to be supplied by civil contractor at terrace).

1368

-

-

... More
Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20(1:'1.5:3) r'naintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr

1368

-

-

... More
Provrding and filling of Groove between 25 mm PCC Panels with PolysLrlphide Sealant (Poring Grade)as per drawings and technical specifications and dii-ection of E in Charge (with 1B% GST).Brand:-Sika- Polysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent

1368

-

-

... More
Toilet/Kitchen Water proofing: 1) Surface preparation by grinding machine, cleaning , crack filling etc. complete.Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry

174

-

-

... More
Basement waterproofing 2) External Treatment on Retaining Wall: Providing and laying 1.6 mm thick, non perforated ,HDPE cross laminated film faced self adhesive bituminous waterproofing membrane Dr. Fixit Samshield XL 1500 over the PCC etc as complete. The elongation (L/T) % should be 230/180 as per ASTM D 882, Tensile strength (L/T) ( N/mSQM) should be 42/48 as per ASTM D 882, Tear Resistance (L/T) (N) 340/310 as per ASTM D 1004 , Puncture Resistance should be more than 220 N as per ASTM E 154 , Hydrostatic pressure more than 50 m as per BS EN 12390 ( Part 8 ), Water absorption @24 hrs (g/SQM) should be 0.14 % as per ASTM D 570 , Water vapor transmission (g/SQM/24 hours) should be less than 0.1 as per ASTM E 96 , Chemical resistance (pH) should be 2.5 – 11.5 as per ASTM D 543 and Crack bridging ability should be more than 1.5 mm as per ASTM C 836.

2830

-

-

... More
a) Providing protection board of geodrain boad of 10mm thick fixed on to the membrane complete as per the specification and drawing. (In client's Scope)

2830

-

-

... More
Termination at vertical 3) Use a C- Shaped aluminium flashing strip or tuck it into a concrete wall of a groove of 12mmx12mm .T he aluminium flashing can be fitted to press the membrane into the groove and then be filled with a single component Dr. fixit PU sealant .

2830

-

-

... More
5.7.3 Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.

14422.94

-

-

... More
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.

11927

-

-

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

3457

-

-

... More
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.

2289.31

-

-

... More
Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 SQM) SQM 57.85

2289.31

-

-

... More
DSR 13.45.1 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 SQM) over and including priming coat of exterior primer applied @ 2.20kg/10 SQM

2289.31

-

-

... More
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and m anufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats

3457

-

-

... More
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats

10966

-

-

... More
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

634.5

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately):For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)

26

-

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)

26

-

-

... More
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.

4.32

-

-

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/ structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent biMTR.allic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the periMTR.er for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all omplete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in SQM. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 SQM from the certified laboratories accreditated by NABL (National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing MTR.hod for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331- 09 testing MTR.hod for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing MTR.hod for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME- 330-10 testing MTR.hod for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing MTR.hod for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”

679.67

-

-

... More
Providing, assembling and supplying vision glass panels (SGUs) comprising of hermetically-sealed 6mm insulated glass ( glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The SGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of SGUS Panels in the curtain glazing is included in cost of item No.25.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

679.67

-

-

... More
Providing and supplying aluminium extruded tubular and other aluminiun sections as per the architectural drawing and approved shop drawings,the aluminiun quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in -Charge .( The item includes cost of material such as cleats ,sleeves,screws etc necessary for fabrication of extruded aluminiun frame work.Nothing extra shall be paid on this account.)

679.67

-

-

... More
providing and fixing of cement board colour and textured including cnc cutting all complete as per engineer-charge.

348.96

-

-

... More
Passenger Lifts 10 TO 13 Passenger 884 kgs B+G+5, Power operated, ACVVVF, 1.5 speed M/Sec. of approved design and make

1

-

-

... More
Passenger Lifts 10 TO 13 Passenger 884 kgs B+G+6, Power operated, ACVVVF, 1.5 speed M/Sec. of approved design and make

2

-

-

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/SQM (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm Each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing periMTR.er channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the periMTR.er of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMTR.er channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of periMTR.er channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with: 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-

1451.23

-

-

... More
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). Floor Joint of 100 mm gap

155

-

-

... More
Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063.) Wall Joint of 100 mm gap

200

-

-

... More
Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) Roof Joint of 100 mm gap

34

-

-

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge

400

-

-

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge

750

-

-

... More
CEMENTS (UPTO 3KM LEAD)

737.7

-

-

... More
SAND (UPTO 35KM LEAD)

918.76

-

-

... More
CHIPS (UPTO 17KM LEAD)

282.34

-

-

... More
STEEL (UPTO 3KM LEAD)

628.2

-

-

... More
BRICKS (UPTO 8KM LEAD)

674.88

-

-

... More
Boundary wall :-Earth Work in excavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I

139.13

-

-

... More
5.1.7Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).

95.05

-

-

... More
Chapter II - 2.11, 2.12 & 2.13 Removal & disposal of surplus excavated earth by mechanical transport including loading unloading stacking and spreading at all lift and lead up to 13km to spoil dump approved by local authority.

44.08

-

-

... More
5.3.1. 6 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

17.08

-

-

... More
5.3.29.1 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. All works upto plinth level

46.73

-

-

... More
5.3.29.2 All works above plinth level upto floor V level

14.26

-

-

... More
DSR 5.9.1 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete

52.29

-

-

... More
DSR 5.9.5 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers

27.5

-

-

... More
DSR 5.9.6 Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts

174.24

-

-

... More
5.5.4 Providing Tor steel reinforcement of 8mm. Dia rods as per approved -do- TMT Fe 500 (only valid for Tata (Tiscon), SAIL, JSPL, Electosteel Steels Ltd, BOKARO and Vizag (RINL)

0.72

-

-

... More
5.5.5 a Providing Tor steel reinforcement of 10mm, 12mm & 16mm dia bars as per approved -do- TMT, 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL, Electosteel Steels Ltd, BOKARO and Vizag (RINL)

0.98

-

-

... More
Above 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL, Electosteel Steels Ltd, BOKARO and Vizag (RINL)

3.42

-

-

... More
Providing Designation 100A B/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9"x4.5"x3") in cement mortar (1:6) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints,cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.

71.76

-

-

... More
Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20x6mm M.S. flats or 16mm square bars fitted on 25x25x6mm M.S Angle frame including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l.

1560

-

-

... More
5.7.3 Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.

863.24

-

-

... More
DSR 13.45.1 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 SQM) over and including priming coat of exterior primer applied @ 2.20kg/10 SQM

863.24

-

-

... More
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l.

517.94

-

-

... More
CEMENTS (UPTO 3KM LEAD)

5.73

-

-

... More
SAND (UPTO 35KM LEAD)

9.66

-

-

... More
CHIPS (UPTO 17KM LEAD)

12.9

-

-

... More
STEEL (UPTO 3KM LEAD)

4.88

-

-

... More
BRICKS (UPTO 8KM LEAD)

71.76

-

-

... More
ROAD :-Excavation in soil using Hydraulic Excavator CK 90 and Tippers with disposal up to 1000 meters. (excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including setting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within al lifts and lead up to 1000m) including Royalty @ Rs. 24.00 per cum, cost of watering, rolling & compaction.

200

-

-

... More
Granular sub-base with coarse graded material (Table 400-2) (construction of granular sub base by providing coarse graded material, spreading in uniform layers with motor graded in prepared surface, mixing by mix in place method with rotator ta OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401) For grading-I Material

150

-

-

... More
wet mix macadam ( providing laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in sub - base / base course on well prepared surface and compacting with vibratory roller to achieve desired density. With Vibratory Roller

100

-

-

... More
Prime coat ( providing and applying primer coat with bitumen emulsion on prepared surface of granular base including clearing of road surface and spraying primer at the rate of 0.60kg/sqm using mechanical means.

1000

-

-

... More
RCD 5.2 Providing and applying teck coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20kg per sqm on the prepared bituminous / granular surface cleaned with mechanical broom.( i) on granular surface treated with primer

1000

-

-

... More
RCD 5.2 ( ii) on bituminous surface.

1000

-

-

... More
Dense Graded bituminous macadam ( providing and laying dense bituminous macadam with 100 - 120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and aligment, rolling with smooth wheeled, vibratory and tandem rollers to achive the desired compaction as per MoRTH specification clause no. 507 complete in all respects. with modifed graded bitumen.For Grading II ( 19MM nominal size )

50

-

-

... More
Semi-Dense bituminous concrete ( providing and laying dSemi-Dense bituminous concrete with 100 - 120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and aligment, rolling with smooth wheeled, vibratory and tandem rollers to achive the desired compaction as per MoRTH specification clause no. 508 complete in all respects. For Grading I ( 13 MM NOMINAL SIZE)

25

-

-

... More
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408 Using Concrete Mixer

500

-

-

... More
Retro- reflection traffic signs ( providing and fixing of retro- reflectorised cautionary, mandatory and informatory sig as per IRC" 67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting , 1.5mm thick supported on mild steel angle iron post 75 mm x 75mm x 6mm firmly fixed to the ground by means of properly designed foundation with m15 grade cement concrete 45cm x 45cm 60cm, 60cm below ground level as per approved drawing.( i) 90cm eguilteral traingle

5

-

-

... More
7.1 P.C.C. 1:3:6 in foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 4 days.)

9.38

-

-

... More
oviding designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.

115

-

-

... More
Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.

5

-

-

... More
DSR 10.25.2 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

1080

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).

26.25

-

-

... More
Supplying and stacking at site dump manure from approved source, including carriage up to 1.0 km (manure measured in stacks will be reduced by 8% for payment) Screened through sieve of IS designation 20 mm

3.93

-

-

... More
Screened through sieve of IS designation 16 mm

9.18

-

-

... More
Screened through sieve of IS designation 4.75 mm

13.12

-

-

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage up to 5.0 km (cattle manure measured in stacks will reduced by 8% for Payment)

52.5

-

-

... More
DSR 2016. 2.1 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure)

105

-

-

... More
Rough dressing the trenched ground including breaking clods

350

-

-

... More
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation

350

-

-

... More
Fine dressing of the ground

350

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge

105

-

-

... More
Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Engineer-in-charge (cost of sludge, dump manure and / or good earth to be paid separately).

105

-

-

... More
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts

350

-

-

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, levelling etc including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50.0 m, lift up to 1.50 m complete (cost of sludge, manure or extra earth to be paid for separately)

105

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)

-

-

-

... More
Holes 60 cm diameter and 60 cm deep

100

-

-

... More
DSR 20162.1 Grassing with selection No1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately)

-

-

-

... More
In rows 5 cm apart in both directions

350

-

-

... More
MAINTENANCE WORKS :- Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but excluding the cost of sludge or manure (the good earth shall be paid for separately)

350

-

-

... More
PLUMBING WORK SANITARY FIXTURES & CP FITTINGS: Sizes of all Sanitary fixtures given are for identification and may very with + 10% dimensions for similar models of other makes, finally approved at no extra cost. Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C of parry Hindustan or any other I.S.S.approved make with 100mm H.C.I. ‘p’ trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S.equivalent make, complete with all fittings,C.I. or C.C brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of vitreous white glazed earthenware ware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.

5

-

-

... More
Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/I. (ii) E.W.C. with 'S' trap (a) 12.5 lit. low level C.I. Cistem

31

-

-

... More
Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.

19

-

-

... More
Supplying fitting and fixing white glazed fire’s clay sink of approved make with overflow arrangements supported on C.I. or R.S. painted brackets 40mm. dia C.P.brass waste with C.P.brass chain and rubber plug 40 mm dia P.V.C. waste pipe about 750mm long with brass coupling at one endand 15mm C.I. body brass spindle bib cock of approved quality of weight not less than 450grams. including cutting wall and making good the same etc. all complete as per specification and direction of E/I. (i) Kitchen sink 600 mm x 450 mm x 250 mm 510x1040 mm bowl depth 250mm

4

-

-

... More
Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete Flexible Pipe 32mm Dia

23

-

-

... More
Providing and fixing PTMT Bottle Trap for Wash basin. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.

19

-

-

... More
Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms

6

-

-

... More
Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350gms.) with extra socket all complete as per specification and direction of E/I.

35

-

-

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore

4

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.

108

-

-

... More
Providing and fixing uplasticised PVC connection pipe with brass 15 mm nominal bore

108

-

-

... More
Supplying, fitting and fixing flat back or angular, lipped front vitreous white glazed earthen ware urinal of ‘Hindustan "Parry" or any other approved I.S.S make with 5 liters capacity C.I. automatic fulsing cistern of reliance for any other I.S.S. approved make with all fittings with C.I.or R.S. brackets, standard size G.I. flush pipe with fitting clamps,15mm C.I. body brass spindle stop cock of approved quality weight not less than 400grams, 15mm P.V.C./Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/I. (a) Flat back or standing corner (600mmx350mm)

15

-

-

... More
Providing and fixing toilet paper holder :

31

-

-

... More
Providing & Fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same material with snap fittings of approved quality and colour, weighing not less than 105 gms

19

-

-

... More
Providing and Fixing in position Hindware make or equivalent CP Grab Bar with wall flanges 600 mm to wooden cleats with C.P. brass screws complete in all respects.

4

-

-

... More
Providing, Fixing, testing and commissioning of C.P. brass wall/counter mounted Single Lever sink mixer with C.P. wall flange, overhead swinging spout/goose neck complete as required and making good Including necessary wall cutting / chasing and making good, as required of make parryware diamond range or equivalent as per direction of Engineer in Charge. HINDWARE make - ELEMENT (Cat No. F360027) / Equivalent

4

-

-

... More
Supply and fixing HINDWARE make or equivalent Health Faucet with 8 mm dia, flexible tube with wall hook and Angle stop cock with wall flange . Etc all as directed by Engineer In-Charge.HINDWARE make Health Fauce - 1.25 Mtr. long (Cat No. F160013)/ Equivalent

31

-

-

... More
Providing and Fixing in position best HINDWARE make Vitreous Chinaware partition slab for urinals, size 690X165X325mm, all as specified and directed. (Cat. No. 61001 of HINDWARE make) / Equivalent

15

-

-

... More
INTERNAL DRAINAGE (SOIL, WASTE,VENT & RAIN WATER DISPOSAL PIPES FITTINGS): Providing, Fixing, testing and commissioning of UPVC pipe SWR type 'B' conforms to IS : 13592-1992 with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint. 110 mm (OD) SWR Pipe

405

-

-

... More
Providing, Fixing and laying cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate, 20 mm down gauge) 75 mm in bed and all around UPVC waste pipes under floor, including shuttering and necessary reinforcement etc. complete as required for: - 100 mm dia

90

-

-

... More
Providing, Fixing, testing and commissioning of UPVC 'P' trap/floor trap/urinal trap of self cleansing design with or without horn conforming to IS : 14735-1999 including setting with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 hard stone ballast 20 mm nominal size) cutting and making good the walls & floors. 110 mm (OD) x 110 mm (OD)

47

-

-

... More
Providing, Fixing, testing and commissioning of UPVC cleanout plug conforming to IS : 14735-1999 complete with all fitting; accessories and civil work. 110 mm OD

10

-

-

... More
Providing, Fixing, testing and commissioning of UPVC waste Pipe conforming to IS : 4985-2000 class IV (6 Kg/Sq.cm) including all moulding fittings conforming to IS : 7834 (Part-1 - Part -7) 1987 such as tees, bends, reducers, coupling, adopters etc. solvent welded joint as per manufacturer recommendation including cutting and making good the walls, floors, R.C.C. work etc. (For waste connection) 32 mm (OD)

24

-

-

... More
40 mm (OD)

24

-

-

... More
50 mm (OD)

40

-

-

... More
Providing, Fixing UPVC floor drain including all fitting and accessories fixed in cement mortar complete in all respect. 110 mm OD x 63 mm OD

18

-

-

... More
Providing, Fixing, testing and commissioning of UPVC inlet fittings with maximum 3 inlets 40, 50 & 63 mm OD size UPVC sockets, fixed to CI/UPVC traps including solvent weld joint/rubber ring joint complete with all civil work.

47

-

-

... More
Providing and fixing PTMT grating of approved quality, colour and make 125 mm nominal dia with 25 mm waste hole

65

-

-

... More
Providing and fixing straight/offset type flexible single body push fit type WC Pan Connector with factory supplied spring loaded seal guard with integrated single mould sealing fins made of flexible EVA Body, including bush/adaptor for use with CI Pipe as supplied with Pan Connector (For European water closet).

31

-

-

... More
Providing and fixing in position stainless steel cockroch trap consisting of 0.45 mm thick inner and outer cup and 1.00 mm thick top grating (Jali) with ring to be fixed inside C.I. or uPVC ‘P’ traps with cement concrete.

39

-

-

... More
RAIN WATER DISPOSAL Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes confirming to IS : 13592 Type A including jointing with seal ring confirming to IS : 5382 leaving 10mm gap for thermal expansion and with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint. 160 mm OD

216

-

-

... More
: Providing and laying cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate, 20 mm down gauge) 75 mm thick in bed and all around UPVC pipes under floor, including shuttering and centering for: -

24

-

-

... More
160 mm dia

-

-

-

... More
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighting not less than 440 grams.

8

-

-

... More
DOMESTIC / FLUSHING/ HOT WATER SUPPLY :

-

-

-

... More
CPVC Pipe Embedded in Wall :(Internal)

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
15 mm nominal OD

170

-

-

... More
20 mm nominal OD

118

-

-

... More
25 mm nominal OD

24

-

-

... More
CPVC Pipe (Exposed) :

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
15 mm nominal OD

22

-

-

... More
20 mm nominal OD

30

-

-

... More
25 mm nominal OD

80

-

-

... More
32 mm nominal OD

150

-

-

... More
40 mm nominal OD

60

-

-

... More
50 mm nominal OD

120

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
62.5 mm nominal OD

40

-

-

... More
Thermal Insulation on CPVC Pipe Embedded in Wall

-

-

-

... More
Providing & fixing thermal insulation on hot water pipes a flexible electomeric foam of closed cells structure having thermal conductivity of 0.038 W/M.K at 40o C, water vapour permeability fire propagation including all accessories e.g. adhesive and ape on joint complete as per specification. All joints shall be sealed with adhesive & cotton tape.

-

-

-

... More
22.2 mm (OD) [6mm thick insulation]

30

-

-

... More
Thermal Insulation on CPVC Pipes (Exposed)

-

-

-

... More
Providing & fixing thermal insulation on hot water pipes, a flexible electomeric foam of closed cells structure having thermal conductivity of 0.038 W/M.K at 40o C, water vapour permeability fire propagation including all accessories complete as per specification. All joints shall be sealed with adhesive & cotton tape, shall be applied to give uniform appearance & finished with polyshield protective coating. ( Pipe On Terrace )

-

-

-

... More
28.6 mm (OD)

6

-

-

... More
54.0 mm (OD)

120

-

-

... More
Providing and fixing Gun metal full way valve of approved qualtiy, all complete as per specification and direction of E/l

-

-

-

... More
(a) 15 mm dia wt not less than 300 gms

3

-

-

... More
(a) 20mm dia wt not less than 400 gms

3

-

-

... More
(a) 25 mm dia wt not less than 500 gms

6

-

-

... More
(a) 32 mm dia wt not less than 700 gms

2

-

-

... More
(a) 40 mm dia wt not less than 1kg

2

-

-

... More
Providing and fixing forged brass auto air vent valve PN10 (10.00 Kg/cm2) rating including all fitting with ball valve & accessories.

-

-

-

... More
15 mm dia

2

-

-

... More
Butterfly Valves :

-

-

-

... More
Providing, fixing, testing & commissioning of wafer type cast iron butterfly valves conforming to BS 5155 & IS 13095 tested to 15 Kg/Sq.cm pressure for maximum working pressure of 10 bar (PN 10) including all fitting and accessories (Drain, water meter for OH Tank/Riser).

-

-

-

... More
50 mm dia

4

-

-

... More
65 mm dia

6

-

-

... More
80 mm dia

5

-

-

... More
EXTERNAL WATER SUPPLY:

-

-

-

... More
2.10.1.2 Excavating trenches of required width for pipes including excavation for sockets also including for cement concrete craddles, and dressing of sides, ramming of bottoms, depth up to 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer with minimum 95% by ramming, watering etc. and disposing off surplus excavated soil as directed, within a lead of 50 m.

-

-

-

... More
Pipes exceeding 80 mm dia but not exceeding 300mm dia.

144

-

-

... More
DSR 18.27 Providing, laying in position, testing & commissioning of S & S cast spun pipes conforming to IS : 1536 class 'LA' including all fittings conforming to IS : 1538 e.g. bends, tees, reducers, blank flanges, tyton joints as per IS : 3144, effective proper connection, cutting chase hole in walls & floors and making good wherever required, bed concrete & sand filling as required including thrust blocks at bends. [Location : From Bore Well/Tanker water supply line/Municipal line to Underground Water Storage Tank].

-

-

-

... More
100 mm dia

144

-

-

... More
Sluice Valve :

-

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
80 mm dia

1

-

-

... More
DUAL PLATE NON RETURN VALVE :

-

-

-

... More
Providing and fixing gun metal non- return valve of approved quality (screwed end) :

-

-

-

... More
80 mm dia Horizontal

1

-

-

... More
Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :

-

-

-

... More
80 mm dia

1

-

-

... More
Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 :

-

-

-

... More
80 mm dia

1

-

-

... More
Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

1

-

-

... More
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :

-

-

-

... More
80mm dia

1

-

-

... More
GARDEN HYDRANT SYSTEM :

-

-

-

... More
Providing, laying, testing & commissioning of UPVC pressure pipes of 10Kg/Sq.cm pressure rating class V (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead upto 50m complete, compaction and consolidation including bed concrete (if required), sand bedding all around UPVC pipe & fittings and thrust blocks at bends as per standard design (For garden hydrants).

-

-

-

... More
25 OD

50

-

-

... More
32 OD

20

-

-

250

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :

-

-

-

... More
25 mm nominal bore

25

-

-

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

25

-

-

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

1

-

-

... More
Butterfly Valve :

-

-

-

... More
Providing, fixing, testing & commissioning of wafer type cast iron butterfly valves conforming to BS 5155 & IS 13095 tested to 15 Kg/Sq.cm pressure for maximum working pressure of 10 bar (PN 10) including all fitting and accessories (Drain, water meter for OH Tank/Riser).

-

-

-

... More
65 mm dia

1

-

-

... More
EXTERNAL SEWERAGE :

-

-

-

... More
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil

15

-

-

... More
2.10.1.2 Earth Work in Excavation of required width for storm and sewer pipes including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil and then returning the soil as required in layer not exceeding 20 cms in depth including consolidating each deposited layers by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50 m. for all kinds of soil.

-

-

-

... More
Pipes, exceeding 80 mm dia but not exceeding 300 mm dia.

192

-

-

... More
Extra for excavating trenches for pipes, cables etc in all kinds of soil for depth exceeding 1.5m, but not exceeding 3m. (Rate is over corresponding basic item for depth up to 1.5 metre

130

-

-

... More
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering,

5

-

-

... More
13.1.1 12 mm cement plaster of mix : 1:4 (1 cement : 4 fine sand)

35

-

-

... More
Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:2 (1 cement :2 fine sand) and spun yarn including testing of joints.

-

-

-

... More
150 mm dia.

48

-

-

... More
200 mm dia.

144

-

-

... More
DSR 19.2 Providing and laying 150 mm thick cement concrete 1:5:10 mix ( 1 cement : 5 coarse Sand : 10 graded stone aggregate 40 mm nominal size) alround SW pipe including bed concrete 150 mm as per standard design.

-

-

-

... More
150 mm dia S.W. pipe

48

-

-

... More
200 mm dia. S.W. pipe

144

-

-

... More
Constructing water tight brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement :4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size). Foundation concrete 150 mm thick 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size), inside and outside plastering 12 mm thick with cement plaster 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels and benching in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design,complete with SFRC cover Heavy duty of adequate size as per standard design and approved drawings . (Price shall include the, cost of excavation, back filling, disposal of surplus earth, dewatering & water proofing of manholes as directed at site & other associated civil works).

-

-

-

... More
Inside size 900mm x 800 mm x 450 mm deep.

3

-

-

... More
Extra over item No. 4 (a) for depth exceeding 45 cm to 90 cm.

0.5

-

-

... More
Providing and fixing square mouth (S.W) gully trap grade `A' complete with C.I. grating brick masonry chamber with bricks of class designation 75 and water tight double seal C.I. cover with frame of 300 x 300 mm internal size. The weight of cover to be not less than 4.5 kg and frame to be not less than 2.70 kg. as per standard design.

-

-

-

... More
150 x 100mm size 'P' type

4

-

-

... More
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement outside rought cement planter 15 mm thick with CM 1:3 (1 cement:3 coarse sand), foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement all complete as per standard design.

-

-

-

... More
0.91 m deep with S.F.R.C. cover and frame (heavy duty HD-20 grade designation) 560mm dia at top conforming to IS 12592, total weight of cover and frame to be not less than 182 Kg., fixed in cement concrete 1:2:4 (1 cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size) including excavation in all kinds of soil refilling centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately).

-

-

-

... More
With F.P.S. bricks class designation 75.

5

-

-

... More
Extra depth for circular type manhole 0.91 M internal dia (at bottom) with F.P.S. bricks beyond 0.91 M to 1.67 M.

1

-

-

... More
Constructing water tight brick masonry grease trap with first class bricks in cement mortar 1:6 (1 cement :6 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size, foundation concrete 150 mm thick 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement & M.S. foot rests including fixing in 20 x 20 x 10 cm cement concrete blocks 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size), two brick masonry baffle walls each of 500 mm depth deep each of 115 mm thickness, 2 Nos C.I. double seal medium duty covers each of 450 x 450 mm size including excavation, backfilling & disposal of surplus earth with a lead upto 50m complete as per standard design.

-

-

-

... More
(Note: Cost shall include dewatering & water proofing of Grease trap as directed at site).

-

-

-

... More
Grease Trap (Size 1200 x 900 x 1000 mm overall depth).

1

-

-

... More
DSR 18.27 Providing & laying S & S cast spun pipes conforming to IS : 1536 class 'LA' including all fittings conforming to IS : 1538 e.g. bends, tees, reducers, blank flanges, tyton joints as per IS : 3114, effective proper connection (For External Sewer Line + Bypass line from Equalization tank to municipal sewer) complete i/c excavation/back filling, bed concrete, sand bed, painting two or more coats with synthetic enamel paint ovr a coat of primer.

-

-

-

... More
100 mm dia

100

-

-

... More
STORM WATER DRAINAGE:

-

-

-

... More
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil

40

-

-

... More
2.10.1.2 Earth Work in Excavation of required width for storm water drainage pipes including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil and then returning the soil as required in layer not exceeding 20 cms in depth including consolidating each deposited layers by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50 m for all kinds of soil.

-

-

-

... More
Pipes, exceeding 80 mm dia but not exceeding 300 mm dia.

300

-

-

... More
Extra for excavating trenches for pipes, cables etc in all kinds of soil for depth exceeding 1.5m, but not exceeding 3m. (Rate is over corresponding basic item for depth up to 1.5 metre

-

-

-

... More
Pipes, exceeding 80 mm dia but not exceeding 300 mm dia.

200

-

-

... More
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering,

32

-

-

... More
13.1.1 12 mm cement plaster of mix : 1:4 (1 cement : 4 fine sand)

85

-

-

... More
Providing, laying and jointing light duty non-pressure NP2 class S/S R.C.C. pipes with collars jointing with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including curing, testing of joints etc.

-

-

-

... More
250 mm dia

180

-

-

... More
300 mm dia

120

-

-

... More
DSR 19.2 Providing and laying 150 mm thick cement concrete 1:5:10 mix ( 1 cement : 5 coarse Sand : 10 graded stone aggregate 40 mm nominal size) alround SW pipe including bed concrete 150 mm as per standard design.

-

-

-

... More
250 mm dia.

180

-

-

... More
300 mm dia.

120

-

-

... More
CATCH BASIN CHAMBER FOR STORM WATER:

-

-

-

... More
Constructing brick masonry road gully chamber 50 x 45 x 60 cm unit brick of class designated 75 in cement mortar 1:4 (1 cement :4 coarse sand) including 500 x 450 mm precast RCC horizontal grating with frame complete as per standard design.

30

-

-

... More
Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 ( 1 cement :4 coarse sand) with pre-cast R.C.C. vertical grating complete as per standard design:

15

-

-

... More
With common burnt clay F.P.S.(non-modular) bricks of class designation 7.5.

-

-

-

... More
Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 ( 1 cement :4 coarse sand) including 500x450mm pre-cast R.C.C. horizontal grating with frame & vertical grating complete as per standard design:

15

-

-

... More
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement outside rough cement plaster 15 mm thick with CM 1:3 (1 cement:3 coarse sand), foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement all complete as per standard design.

-

-

-

... More
0.91 m deep with S.F.R.C. cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to IS 12592, total weight of cover and frame to be not less than 182 Kg., fixed in cement concrete 1:2:4 (1 cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering shuttering all complete. (foot rests shall be paid for separately).

-

-

-

... More
With F.P.S. bricks class designation 75.

10

-

-

... More
Extra depth for circular type manhole 0.91m Internal dia (at bottom) with beyond 0.91 m to 1.67m.

1

-

-

... More
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement all complete as per standard design.

-

-

-

... More
1.68 m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560 mm dia at top conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately).

-

-

-

... More
With F.P.S. bricks class designation 75.

5

-

-

... More
Extra depth for circular type manhole 1.22 M internal dia (at bottom) with F.P.S. bricks beyond 1.68 M to 2.29 M.

1

-

-

... More
RAIN WATER HARVESTING SYSTEM :

-

-

-

... More
Construction of rain water harvesting size 3m dia x 3.5m effective depth for the re-charging of storm water run off including the civil work with following specification [Construction of Chamber].

-

-

-

... More
DE-SILTING CHAMBER:

-

-

-

... More
Providing and constructing mansonary de-silting chamber 2000mm x 1200mm x 2000-3700 mm depth inside with 75 class designated brick work in cement mortar 1:6 (1cement : 6 fine sand) with SFRC Heavy duty 560mm dia manhole cover (2Nos.). top slab 1:2:4 mix (1cement : 2coarse sand : 4 graded stone aggregate 20mm nominal size) with minimum 1.5% reinforcement, foundation concrete 1:5:10 (1cement : 5 fine sand:10 grade stone aggregate 20mm nominal size including baffle wall, necessary excavation, back filling and disposal of surface earth. Complete with inlet, outlet and overflow arrangement. Foot rest @400mm c/c, grating of required size with 16mm sq.bars and frame @20mm clear spacing fixed at month of pipe as per site conditions and direction of Engineer incharge

-

-

-

... More
OIL AND GREASE SEPARATOR CHAMBER:

-

-

-

... More
Providing and constructing oil and grease separator chamber 1200 x 2500mm x 2000-3700 mm depth with required depth inside with 75 class designated brick work in cement mortar 1:6 (1cement : 6 fine sand) with 560mm dia SFRC Heavy duty manhole cover (2Nos.) top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) with minimum 1.5% reinforcement foundation concrete 1:5:10 (1cement: 5 fine sand and 10 graded stone aggregate 20mm nominal size including two brick mansonary baffle walls, with necessary excavation, back filling and disposal of surface earth compete with inlet, outlet, PVC coated foot rest.

-

-

-

... More
DRILLING:

-

-

-

... More
Drilling percolation borehole 200mm dia with reverse rotary method in all types of soil 40-45m depty including cost for mobilization of rig and making good the area upon completion of work. Contractor shall arrange for all necessary tools, water and consumable and laying for drilling.

-

-

-

... More
Providing and laying pea gravel all around the casing pipe.refer schematic section proided in side plan.

-

-

-

... More
160 mm dia slotted UPVC pipe of 6 Kg/cm2 - 35 m -40m or as per site sub-strata or set as per direction of Engineer- in charge.refer schematic section proided in side plan.

-

-

-

... More
160 mm dia UPVC blind pipe of 6 Kg/cm2.

-

-

-

... More
RAIN WATER HARVESTING WELL FILTRATION CHAMBER:

-

-

-

... More
Providing and constructing rain water harvesting well/filtration chamber of size 3m dia x 3.5m eff. depth inside with 75 class designated brick work in cement motor 1:6 (1cement : 6 fine sand) with 560mm dia C.I double seal medium duty manhole cover with top slab 1:2:4 mix (1cement : 2 course sand :4 graded stone aggregate 20mm nominal size) with minimum 1.5% reinforcement , foundation concrete 1:5:10 (1cement : 5 fine sand and 10 graded stone) aggregate 20mm nominal size including 500mm depth. Boulder 10-20mm, 500mm depth, gravel 5-10mm size, 500mm depth coarse sand 1.5-2.0mm including necessary excavation, back filling and disposal of surface earth complete with inlet, outlet, overflow arrangement pvc coated Foot Rest, 100mm dia weep holes @500mm c/c to be provided 1200 c/c above the bottom of wall, 100mm C.I vent pipe -2m height with cowls.

-

-

-

... More
Rate shall include excavation, back filling and all other operations necessary for completing the job.

1

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30 x 20 x 15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

50

-

-

... More
MISCELLANEOUS ITEMS:

-

-

-

... More
PUDDLE FLANGE FOR WATER TANKS

-

-

-

... More
Providing and fixing M.S fabricated epoxy coated(two layers) galvinised coating puddle flange comprising of 600 mm dia long M.S class 'C' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size upto 150 mm dia & 7.1 mm thick mm plate for pipe dia above 150 mm dia including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Location: underground/ overhead tanks.)

-

-

-

... More
25 mm dia

8

-

-

... More
32 mm dia

1

-

-

... More
40 mm dia

1

-

-

... More
50 mm dia

4

-

-

... More
65 mm dia

4

-

-

... More
80 mm dia

8

-

-

... More
100 mm dia

16

-

-

... More
200 mm dia

2

-

-

... More
Providing and placing on terrace storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].G.I VENT PIPE

40000

-

-

... More
Providing and fixing G.I. Vent Pipe class 'B' (medium duty) for R.C.C water storage tanks comprising of 600 mm long vertical pipe, return bend with mosquito grating & cast brass perforated coupling including all associated civil work. 100 mm dia

12

-

-

... More
Providing and fixing of mosquito overflow grating /Jali of the following diameters including all fitings & accessories :- 100 mm dia

12

-

-

... More
Water Supply, Drainage Pumps & Water Treatment Equipments

-

-

-

... More
Supply, installation, testing & commissioning of vertical inline multistage pumping set (Imported) with Stainless steel body, impeller, casing, shaft and C.I. base & head with mechanical seal, connected to a TEFC induction motor suitable for 415+/- 10% volts, 3 phase 50 cycles A.C. supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundations, 80x40 mm I section base plate bolted to cement concrete foundations complete.Vendor to submit performance curves and technical catalogue of the proposed model for review and information.

-

-

-

... More
Filter Feed Pump (Dom. Water) at Water Supply Pump Room

-

-

-

... More
Set of Two Pumps (1 Working+ 1 Standby)

-

-

-

... More
Capacity 2.0 LPS

-

-

-

... More
Head 25 M.

-

-

-

... More
HP 2.0 HP Approxi.

1

-

-

... More
Raw Water Transfer Pump to STP at Pump Room

-

-

-

... More
Set of Two Pumps (1 Working+ 1 Standby)

-

-

-

... More
Capacity 1.0 LPS

-

-

-

... More
Head 25 M.

-

-

-

... More
HP 1.0 HP Approxi.

1

-

-

... More
Irrigation Pump at STP Pump Room

-

-

-

... More
Set of Two Pumps (1 Working+ 1 Standby)

-

-

-

... More
Capacity 4.0 LPS

-

-

-

... More
Head 40 M.

-

-

-

... More
HP 5.0 HP Approxi.

1

-

-

... More
Providing, installing, testing and commissining of fixed speed hydropneumatic system mounted on a common base plate comprising of vertical centrifugal pumping set with S.S body, stainless steel impeller and mechanical seal, shaft directly coupled to a TEFC induction motor suitable for 400/440 volts, 3 phase, 50 cycles AC supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundation, one No. microprocessor based controller, one No.remote sensors, pressure transducers, sequence running cotroller, dry running Protection,motor control centre, necessary power and control cabling from MCC to pumps including required rating of MCB, one No. 100 litre capacity M.S diaphragam tank with interchangeable butyl rubber membrane,complete in all respects,

-

-

-

... More
including stainless steel grade 316 pipe suction and delivery headers and isolation/ control valves( ball valves/butterfly valves/ Nan return valves/ vibration eliminators etc as required) , power box, equipped with fuses/ isolators/circuit breakers as required.

-

-

-

... More
Hyd. System for Domestic Water Supply at Water Supply Pump Room

-

-

-

... More
Set of Two Pumps (1 Working+ 1 Standby)

-

-

-

... More
Capacity 2.5 LPS

-

-

-

... More
Head 45 M.

-

-

-

... More
HP 3 HP Approxi.

1

-

-

... More
Hyd. System for Flushing Water Supply at STP Pump Rm

-

-

-

... More
Set of Two Pumps ( 1 Working+ 1 Standby)

-

-

-

... More
Capacity 1.5 LPS

-

-

-

... More
Head 45 M.

-

-

-

... More
HP 2 HP Approxi.

1

-

-

... More
Supply, installing, testing and commissioning of submersible open impeller non-clog pumps with C.I.body and to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, guide pipe and chain in built level controller, sequence running controller, arrangement for both pumps together inacase of emenegency, audible hooter for failure or flooding, dry running Protection complete in all respects., painting, testing and commissioning complete with approved quality and make as required as per instruction of site incharge.

-

-

-

... More
(Pumps shall be installed in a set of two pumps One working and One standby)

-

-

-

... More
Basement & Pump Room Drainage Pumps

-

-

-

... More
(Pumps to be suitable to handle solids upto 30 mm size)

-

-

-

... More
Capacity - 4.0 LPS (Each)

-

-

-

... More
Head - 15 M

-

-

-

... More
H.P. - 1.5 HP Approx.

1

-

-

... More
Supply Installation,Testing & Commissioning of vertical self supporting Filter fabricated from MS sheet as per IS: 2825, ((minimum thickness of shall 6 mm and dished end 8 mm)) pressure gauges, sample cock, GI class 'C' face piping, CI butterfly valves and all accessories , with initial charge of filter media including anthracite, painting inside with epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint, testing and commissioning complete.

-

-

-

... More
Dual Media Filter For Domestic Water Supply

-

-

-

... More
Capacity- 7200 LPH

-

-

-

... More
Filtration rate- 14000 LPH/Sqm.

-

-

-

... More
Filter dia approx. - 1000 MM

-

-

-

... More
Working pressure: 3.0 Kg/sq cm.

-

-

-

... More
Test pressure : 4. 5 Kg/sq cm

1

-

-

... More
Activated Carbon Filter For Domestic Water Supply

-

-

-

... More
Capacity- 7200 LPH

-

-

-

... More
Filtration rate- 14000 LPH/Sqm.

-

-

-

... More
Filter dia approx. - 1000 MM

-

-

-

... More
Working pressure: 3.0 Kg/sq cm.

-

-

-

... More
Test pressure : 4. 5 Kg/sq cm

1

-

-

... More
Supply Installation,Testing & Commissioning of metering pump type chemical doser with 100 lits. HDPE chemical grade solution tank,injection fitting assembly,suction and delivery hose upto the point of injection, capacity 0-6 lph, complete in all respects.

-

-

-

... More
Chlorination of Domestic Water

1

-

-

... More
Design, manufacture, supplying, fixing in position, testing and commissioning of the following front operated cubicle type, front access 2mm thick mild steel sheet, free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system and suitable for a fault level of 25 MVA symmetrical at 415 volts.

-

-

-

... More
All switchboards shall have provision for entry of cables from the top or bottom as required.

-

-

-

... More
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position.

-

-

-

... More
Electric Panel For Water Supply Pumps at Water Supply Pump Room

-

-

-

... More
INCOMING

-

-

-

... More
1 No. 150 amps TPN MCCB with the following accessories:

-

-

-

... More
1 No. square flush mounting 0-500 volts scaled voltmeter with three way and OFF switch.

-

-

-

... More
Three phase indicating lights.

-

-

-

... More
Electrolytic high conductivity three phase and neutral tinned copper bus bar rated at 200 amps having a current density of 1 amp per Sqmm suitable to with stand symmetrical fault level of 25 MVA at 415 volts. The neutral bus bar is to be of 100% capacity.

-

-

-

... More
OUTGOING UNITS

-

-

-

... More
Four 25 Amp. TP + NL M.C.C.B. with rotary handle of breaking capacity 25KA

-

-

-

... More
01 Nos. TPN MCCB of 63 A with 25 KA service breaking capacity for domestic water hydropneumatic pumps. (Only connection to inbuilt panel of Domestic water hydropneumatic system)

-

-

-

... More
4 Nos. fully automatic DOL starters with push buttons and ON/OFF indicating lights and overload relays for 1.5 to 5 HP pump .

-

-

-

... More
4 Nos. rotary selector switch for selecting mode of operation i.e. auto/manual/off.

-

-

-

... More
4 Nos.cyclic relay for automatic duty changeover of pumps.

-

-

-

... More
4 No. single phase preventors.

-

-

-

... More
4 Nos. square flush mounting 0-30 amps scaled ammeters with three way and OFF selector switch.

-

-

-

... More
Space for 3 Nos. Level Controllers.

-

-

-

... More
Switchgear shall be suitable for the HPS of various motors.

-

-

-

... More
2 Nos. 32 Amp. TPN MCB Spare.

-

-

-

... More
The motor control panel shall be prewired with colour coded wires with identification labels complete in all respects as required.

-

-

-

... More
Motor control centre as described above

1

-

-

... More
For Drainage Sump Pump

-

-

-

... More
One incoming main MCCB unit of 63 amps rating.

-

-

-

... More
Copper bus bar is separate chamber fully taped of 100 amps capacity.

-

-

-

... More
Two MCB units of 25 amps

-

-

-

... More
Two fully automatic DOL starters with push buttons and on/off indicating lights.

-

-

-

... More
One rotary duty selector switch

-

-

-

... More
Two manual/auto/off switches.

-

-

-

... More
Two single phasing presenters.

-

-

-

... More
One panel type voltmeter with rotary selector switch for reading voltage between phases.

-

-

-

... More
Two ampere meters one for each motor.

-

-

-

... More
Three neon phase indicating lights on the incoming mains.

-

-

-

... More
Space for one liquid level controllers.

-

-

-

... More
All internal wiring colour coded from incoming mains to various switchgear, starters, meters, indicating lamps and bus bar with a changeover facility to run each pump alternatively with an alarm bell in case of both pump’s running at one time. Switchegear offered must be compatible with the HP of the motors offered.

-

-

-

... More
Motor control centre as described above

1

-

-

... More
Supplying, installing, testing and commissioning controllers with low voltage relays, stainless steel probes and PVC shroud wiring from tank top to problems of required.

-

-

-

... More
For Water Supply Pump:

-

-

-

... More
To start pump when water level is low in Domestic Water U.G. tank and shut off pump when Domestic Water U.G. tank is full. Also to stop when water level is low in raw water underground tank.

2

-

-

... More
For Sump Pumps:

-

-

-

... More
To start pump when water level is high in sump and shut off pump when sump is empty. Both pumps are start when sump is over flowing.

1

-

-

... More
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete.

-

-

-

... More
50 mm dia

25

-

-

... More
65 mm dia

35

-

-

... More
80 mm dia

45

-

-

... More
100 mm dia

20

-

-

... More
Providing & fixing butterfly valve tested to a pressure not less than 25 Kg/Sq.cm. Including rubber gasket, 2 nos. Table-E flanges, nuts, bolts, washers & painting complete as required.

-

-

-

... More
50 mm dia

5

-

-

... More
65 mm dia

10

-

-

... More
80 mm dia

6

-

-

... More
100 mm dia

2

-

-

... More
Providing & fixing dual plate CI wafer type check valve tested to a pressure of 25 Kg/sqcm. Including rubber gasket, 2 nos. table-E flanges, union, nuts, bolts, washers & painting complete as required.

-

-

-

... More
50 mm dia

4

-

-

... More
65 mm dia

6

-

-

... More
80 mm dia

2

-

-

... More
Providing and fixing resilient rubber neoprene lined style arch vibration eliminators suitable for raw water upto 45 deg.C. Temperature working pressure upto 25 Kg/Sqcm.

-

-

-

... More
50 mm dia

4

-

-

... More
65 mm dia

4

-

-

... More
Providing and fixing heavy duty armoured cables 1.1 KVA grade including necessary support clamps at ceiling level and connection lugs complete in all respects.

-

-

-

... More
Power cable Copper 3 core 10 sq.mm

25

-

-

... More
Power cable Copper 3 core 6 sq.mm

35

-

-

... More
Power cable Copper 3 core 4 sq.mm

35

-

-

... More
Control cable copper 2 core 1.5 sq.mm

75

-

-

... More
Providing and fixing CI Y type suction strainer with gunmetal or brass internal parts installed outside water tanks.

-

-

-

... More
100 mm dia.

2

-

-

... More
Total C/F to Summary

-

-

-

... More
Sewage Treatment Plant

-

-

-

... More
Designing, Supply, installation, Testing and commissioning of complete mechanical and electrical Items with stand by pumps as mentioned in the List of Mechanical equipment’s of the STP-55 KLD based on MBBR technology. (Excluding civil works)

1

-

-

... More
List of Electro-Mechanical Equipments

-

-

-

... More
Bar Screen

-

-

-

... More
Level Switch

-

-

-

... More
Sewage lifting pump

-

-

-

... More
Plant Room Sump Pump

-

-

-

... More
Air Blower

-

-

-

... More
Air dispersion system

-

-

-

... More
Fine bubble diffuser

-

-

-

... More
corse bubble diffuser

-

-

-

... More
Air piping

-

-

-

... More
Sludge recirculation pump

-

-

-

... More
Filter press (Manual)

-

-

-

... More
Screw pump

-

-

-

... More
MBBR media

-

-

-

... More
Tube settler media

-

-

-

... More
Filter feed pump

-

-

-

... More
Multigrade Filter

-

-

-

... More
Activated carbon filter

-

-

-

... More
Pressure guage

-

-

-

... More
Dosing pump

-

-

-

... More
Piping & Fitting

-

-

-

... More
Electrical control panel

-

-

-

... More
Electro Magnetic Flow Meter

-

-

-

... More
Cable & Cable tray

-

-

-

... More
Ulta violet (UV) System

-

-

-

... More
MBBR 1 & 2 Tank (MSFRP)

-

-

-

... More
Tube Settler Tank (MSFRP)

-

-

-

... More
Filter Feed Tank (MSFRP)

-

-

-

... More
Treated Water Storage Tank (MSFRP)

-

-

-

... More
CIVIL WORK (Client scope)

-

-

-

... More
Screen cum Oil & grease chamber

-

-

-

... More
Oil & Grease chamber

-

-

-

... More
Collection Tank

-

-

-

... More
Plant Room

-

-

-

... More
Foundation for equipment

-

-

-

... More
Total C/F to Summary

-

-

-

... More
Fire Fighting System

-

-

-

... More
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :

-

-

-

... More
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.

-

-

-

... More
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.

-

-

-

... More
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.

-

-

-

... More
Suitable cement concrete foundation duly plastered with anti vibration pads.

-

-

-

... More
2280 lpm at 88 m Head

1

-

-

... More
Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm 2 pressure at the highest / farthest point.

-

-

-

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)

-

-

-

... More
Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.

-

-

-

... More
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.

-

-

-

... More
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.

-

-

-

... More
Suitable cement concrete foundation duly plastered with anti vibration pads.

-

-

-

... More
2280 lpm at 88 m Head

1

-

-

... More
Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm 2 pressure at the highest / farthest point.

-

-

-

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)

-

-

-

... More
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.

-

-

-

... More
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.

-

-

-

... More
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.

-

-

-

... More
Suitable cement concrete foundation duly plastered with anti vibration pads.

-

-

-

... More
180 lpm at 88 m Head

1

-

-

... More
Supplying, installation, testing and commissioning of electric driven pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Water Curtain Pump)

-

-

-

... More
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.

-

-

-

... More
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.

-

-

-

... More
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.

-

-

-

... More
Suitable cement concrete foundation duly plastered with anti vibration pads.

-

-

-

... More
900 lpm at 35 m Head

1

-

-

... More
CONTROL PANELS

-

-

-

... More
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :

-

-

-

... More
INCOMING

-

-

-

... More
400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc.

-

-

-

... More
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps

-

-

-

... More
Set of Copper Bus Bar 500A

-

-

-

... More
OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)

-

-

-

... More
Main Fire Pump 200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local / remote, auto/manual/OFF operation.

-

-

-

... More
Jockey Pump 100 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets (1 for water curtain pump)

-

-

-

... More
Diesel Engine Control

-

-

-

... More
Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode

-

-

-

... More
Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication

-

-

-

... More
Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter

-

-

-

... More
All standard relays and accessories for automatic operation of diesel engine

-

-

-

... More
System Controller

-

-

-

... More
Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification.

-

-

-

... More
Control panel as described above

1

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.

-

-

-

... More
150 mm. Dia

320

-

-

... More
100 mm dia.

90

-

-

... More
80 mm dia.

15

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
25 mm dia

2000

-

-

... More
32 mm dia

500

-

-

... More
40 mm dia

500

-

-

... More
50 mm dia

270

-

-

... More
65 mm dia

213

-

-

... More
80 mm dia

280

-

-

... More
100 mm dia

320

-

-

... More
150 mm dia

217

-

-

... More
200 mm dia (wall thickness 6.3 mm)

10

-

-

... More
250 mm dia (wall thickness 6.3 mm)

10

-

-

... More
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia.

25

-

-

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel

14

-

-

... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Stainless steel, Single headed

8

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
80 mm dia

12

-

-

... More
100 mm dia

5

-

-

... More
150 mm dia

8

-

-

... More
200 mm dia

3

-

-

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

22

-

-

... More
Supply & fixing in position ISI marked cast iron double flanged non return valves (PN 1.6 MPa) as per IS:13095, with SS disc, shaft, seating rings, nitrile rubber lining, internal fastening, nuts, bolts including transporting to worksite, 3 mm thick rubber gaskets etc. including testing, Complete as per drawings & directions of the Engineer-in-charge.

-

-

-

... More
80 mm dia

1

-

-

... More
100 mm dia

2

-

-

... More
150 mm dia

2

-

-

... More
200 mm dia

1

-

-

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.

-

-

-

... More
200 mm dia

2

-

-

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :

-

-

-

... More
Stainless Steel (Grade 304)

44

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.

-

-

-

... More
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585

-

-

-

... More
20 mm nominal internal dia gun metal globe valve & nozzle.

-

-

-

... More
Drum and brackets for fixing the equipmets on wall.

-

-

-

... More
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.

-

-

-

14

-

-

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for nstantaneous connection to interconnect hose pipe coupling as required :

-

-

-

... More
Stainless Steel (Grade 304)

22

-

-

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :

-

-

-

... More
4 way - 150 mm dia M.S. Pipe

1

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.

3

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :

-

-

-

... More
Pendent Sprinkler

500

-

-

... More
Upright Sprinkler

700

-

-

... More
Horizontal side wall sprinkler

50

-

-

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.

4

-

-

... More
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.

-

-

-

... More
150mm dia

12

-

-

... More
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :

-

-

-

... More
150mm dia

1

-

-

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.

-

-

-

10

-

-

... More
1000mm

10

-

-

... More
1200mm

10

-

-

... More
1500mm

10

-

-

... More
Supplying, installation, testing & commissioning of deluge valve (to be used for water curtains) UL listed with wet pilot basic trim assembly for DVA with test and alarm, drip and drain valve with water motor gong complete as required.

-

-

-

... More
100 mm dia

1

-

-

... More
Providing, installation, testing & commissioning of water curtain nozzle 15mm dia nickel chrome plated brass, BSPT, K-factor as per design consideration complete as required.

20

-

-

... More
Providing, installation, testing & commissioning of electric release trim assembly for deluge wall with two way solelnoid valve, weather proof operation on 24 volts DC supply complete as required.

1

-

-

... More
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.

500

-

-

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

375

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
4.1.2 150 mm width x 50mm depth x 1.6 mm thickness.

70

-

-

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required

22

-

-

... More
Providing and fixing of Weather proof hose cabinets fabricated from 14 g M.S. Sheet with full glass door and mortise locking arrangement , suitable to accommodate one Hydrant landing valve, 2 nos. 15 M long hose and 1 No branch pipe. The cabinet shall be painted with one coat of primer and finished stove enamelled "Fire Red", "Fire Hose" written on front including suitably mounted on a raised masonry platform as required. (Approx 0.75mx0.6 m x 0.25 m).

8

-

-

... More
Providing and fixing MS partly glazed single/double hung lockable shutter fabricated from MS section as required with 5 mm thick glass for fire station complete including stove enamelled painting of door and frame and words "Fire Hydrant" written on glass, suitable to accommodate 2 Hydrant landing valves, 1 fire hose reel, 2 nos.15m long 63 mm dia hose,1-branch pipe, 1no. fire man's axe, fire extiguishers 2 nos, including suitably mounted on a raised masonry platform as required. (Approx.size 0.90 m x 2.1m )

14

-

-

... More
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators with unit control suitable for raw water upto 450C temperature working pressure 25 kg and test pressure 37.5 kg/cm2.

-

-

-

... More
80 mm dia.

2

-

-

... More
100 mm dia

2

-

-

... More
150 mm dia

4

-

-

... More
Power cable 3.5 core 95 sq mm aluminium conductor armoured cable

25

-

-

... More
Power cable 3 core 16 sq mm aluminium conductor armoured cable.

25

-

-

... More
Control cable 2 core 1.5 sq mm copper conductor armoured cable.

150

-

-

... More
Supply, Installation, Testing & Commissioning of double flanged vertical air vessel fabricated shell from 10 mm thick & dished ends 12 mm thick M.S.plate, suitable for working pressure of 18 kg/cm2 and test pressure of 27 kg/cm2, 450 mm dia and 2.00 m high for fire pumps complete with four nos dual setting pressure switches to operate jockey and main pumps at drop of pressure as given in the specifications.

1

-

-

... More
Providing & fixing 150 mm diameter MS Class ‘C’ for diesel engine exhaust pipe (including all fittings, clamps, steel support) of suitable dia for the diesel engine. The pipe shall be provided insulation with fibre glass wool and wraped with 24g. aluminium sheet complete with all respect.

60

-

-

... More
Providing and fixing of gun metal fire Brigade Suction Hose coupling (Draw-out Connection) with nut for female coupling as per IS:902- 1974 complete with 100 mm dia. G.I. Suction pipe and 100 mm dia. 1No. C.I. Foot valve flanged (to be connected to static water tank).

1

-

-

... More
Providing and fixing carbon-di-oxide type fire extinguishers consisting of pressure tested single cast cylinder with rotary discharge valve and high pressure discharge tube of minimum 1 m length, discharge horn, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with initial charge .

-

-

-

... More
Capacity 4.5 Kg.

18

-

-

... More
Providing and fixing carbon-di-oxide fire extingushers trolley mounted with all accessories internal discharge tube,high pressure discharge hose,discharge nozzle, ISI marked as per IS:2878 finished externally with red enamel paint.

-

-

-

... More
Capacity 22.5 kg.

2

-

-

... More
Providing and fixing ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.

-

-

-

... More
Capacity 6.0 Kg.

18

-

-

... More
Providing and fixing 25 mm dia inspecting & testing assembly with drain valve built in bye pass arrangement and connection to drain line. (Giocomini)

12

-

-

... More
SUB-HEAD I: HT & LT Cables and Terminations

-

-

-

... More
HT CABLE

-

-

-

... More
Supply of cable XLPE -PVC insulated PVC sheathed galvanised steel strip armoured electric power cable with aluminium conductor 11000 volt grade of size 3C X 240 sqmm.

100

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of grade 1.1KV but not exceeding 11 KV of size not exceeding 120 Sqmm but not exceeeding 400 Sqmm direct in Ground including excavation, sand cushioning, protective covering and refilling the trench etc as required 3c x 240 sqmm

70

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of grade 1.1KV but not exceeding 11 KV of size not exceeding 120 Sqmm but not exceeeding 400 Sqmm in the existing RCC/ HUME/STONE WARE / METAL pipe as required. 3c x 240 sqmm

30

-

-

... More
Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240 sq. mm

2

-

-

... More
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 240sq. mm

2

-

-

... More
Supply of LT Cables

-

-

-

... More
3.5 core, 300 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor

334

-

-

... More
3.5 core, 240 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor

65

-

-

... More
3.5 core, 185 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor

180

-

-

... More
3.5 core, 120 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor

280

-

-

... More
3.5 core, 95 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor

82

-

-

... More
3.5 core, 70 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor

160

-

-

... More
3.5 core, 50 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor.

25

-

-

... More
3.5 core, 25 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor.

30

-

-

... More
4 core, 16 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor.

780

-

-

... More
4 core, 10 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor.

1250

-

-

... More
3C-6.0Sq. mm Copper Armoured cable

270

-

-

... More
3C-4.0Sq. mm Copper Armoured cable

20

-

-

... More
4C-6.0Sq. mm Copper Armoured cable

1540

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ STONE WARE / METAL pipe/ Cable Trays as required.

-

-

-

... More
Upto 35 sq. mm

3890

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

247

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

460

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

399

-

-

... More
Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.

-

-

-

... More
3.1/2 core 300 sq. mm.

14

-

-

... More
3.1/2 core 240 sq. mm.

2

-

-

... More
3.1/2 core 185 sq. mm.

2

-

-

... More
3.1/2 core 120 sq. mm.

10

-

-

... More
3.1/2 core 95 sq. mm.

6

-

-

... More
3.1/2 core 70 sq. mm.

12

-

-

... More
3.1/2 core 50 sq. mm.

2

-

-

... More
3.1/2 core 25sq. mm.

2

-

-

... More
4core 16sq. mm.

64

-

-

... More
9.1.32 4core 10sq. mm.

114

-

-

... More
3core 10sq. mm.

34

-

-

... More
9.1.7 3core 6sq. mm.

32

-

-

... More
9.1.7 3core 4sq. mm.

2

-

-

... More
9.1.32 4C-6.0Sq. mm

126

-

-

... More
Cable Trays

-

-

-

... More
4.1 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.( Powder coated shall be of Siemens Grey Colour- RAL 7032)

-

-

-

... More
900 mm width X 75 mm depth X 2.0 mm thickness

50

-

-

... More
750 mm width X 75 mm depth X 2.0 mm thickness

25

-

-

... More
600 mm width X 75 mm depth X 2.0 mm thickness

50

-

-

... More
450 mm width X 50 mm depth X 2.0 mm thickness

50

-

-

... More
300mm width X 50mm depth X 1.6 mm thickness

50

-

-

... More
4.1.2 150mm width X 50mm depth X 1.6 mm thickness

100

-

-

... More
Total of Subhead-I Carried to Summary

-

-

-

... More
SUB-HEAD II: COMPACT SUBSTATION & DG SETS

-

-

-

... More
COMPACT SUBSTATION:

-

-

-

... More
HT SWITCHGEAR (HT Compartment)

-

-

-

... More
11kV 630Amps 20kA for 3 sec. & tested for 20kA/ 1 sec internal arc , SF6 insulated Non-Extensible Compact switchgear consisting of One No. Direct Module for Incomer and one No. of Fixed Manual Vacuum Circuit Breaker in SF6 insulated Stainless steel enclosure with series trip,self powered microprocessor based numerical over current and Earth Fault (IDMT+Inst.) relay protection along with. Interconnection between HT switchgear and transformer shall be using 1Rx3Cx240 sq.mm Al. unarmorured XLPE Cable.

-

-

-

... More
1 Nos. 630A, VCB.

-

-

-

... More
SUBSTATION COMPARTMENT:

-

-

-

... More
Supply, Installing, Testing & Commmissioning of 11 kV Package Substation outdoor type designed for natural cooling having type tested equipment comprising Non extensible RMU, distribution transformer, Low voltage switch board, interconnection between HT switch gear and transformer using single core cables and transformer to LT switch gear using Al. bus bars / cables, factory built / ready for connection type, other associated equipment etc. complete as required conforming to detailed specification laid down in the attached specification. The enclosure shall have modular construction using 2mm GI sheets and 4 mm for base frame and shall be powder coated with RAL 1001 cream paint. The enclosure for LT switchgear & HT switchgear shall be provided with IP 54 ingress protection. The transformer compartment will have IP 23 ingress protection. The transformer used shall be specially designed for low losses as per ECBC norms. The earthing shall be suitable for 35 kA fault current. The various main components of Package Substation shall be as per details below:-

-

-

-

... More
One (1) No., 11/0.433 kV, 1000 kVA, Oil filled Trasnsformer with ON load tap changer with tapping range +5 % to –15% in steps of 1.25% with standard accessories and as per specifications.

-

-

-

... More
LT COMPARTMENT:

-

-

-

... More
Incoming

-

-

-

... More
One (1) No., 1600A, 4P, 35kA ACB with O/C,S/C, E/F protection etc complete and as per specification.

-

-

-

... More
TOTAL OF COMPACT SUB-STATION

1

-

-

... More
DG SETS

-

-

-

... More
Supply, installation, testing and commissioning at 0.8 P.F. (lagging), aircooled radiator type diesel engine alternator set mounted on common base frame complete with accessories as per specification and layout, drawing with battery charger, battery and battery rack residential silencer, stainless steel bellows, 990 Ltrs. day fuel tank, spring loaded GERB cush pads, logic control panel, governor etc including Accoustic Enclosure suitable for outdoor installation complete as required as follows:

-

-

-

... More
750 KVA DG Set

1

-

-

... More
500 KVA DG Set

1

-

-

... More
Battery & Battery Charger

-

-

-

... More
Supply, installation, testing and commissioning of 180 AH capacity 24 volts DC lead acid tubler battery..

2

-

-

... More
Supply, installation, testing and commissioning of SMPS battery charger unit with provisions of Boost Charging, and Float charging. Suitable for 240 V, including DC DB single phase AC 50 Hz as per requirement.

1

-

-

... More
Supply, laying of following sizes of MS Piping for Exhaust including providing suitable bends, reducers & supporting arrangement at suitable intervals including insulation on entire length of exhaust pipe with 75mm thick Rockwool insulation & painting etc. as required.

-

-

-

... More
350mm (NB) MS ERW pipe

45

-

-

... More
250mm (NB) MS ERW pipe

45

-

-

... More
COMPACT SUBSTATION & DG Sets as described above and complete as required

-

-

-

... More
Total of Subhead-II Carried to Summary

-

-

-

... More
SUB-HEAD III: 415V LT PANELS

-

-

-

... More
Design, fabrication, assembling, wiring & supply, installation, testing & commissioning of MV Panels fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA painted sheet steel in cubicle formation with reinforcement of suitable size angle iron, channels, T irons, flats wherever necessary for large meter boards. Cable gland plates shall be provided at top and bottom both and windows for meter reading, locking arrangement (pad-lock & seal) with wiring upto KWH meter & meter to MCB shall be done by using adequately rated flexible single core copper wire. The boards shall be treated with all anticorrosive process before painting as per standards with final approved shade of powder coated as approved, 2 nos. earthing terminals shall be provided for all panels. The boards shall be suitable for 415 V, 3 phase, 4 wire, 50 Hz supply system. Boards shall be fabricated in length, height, depth etc to match with site conditions.

-

-

-

... More
An approval shall be taken for each panel before manufacturing. Galvanised hardwares with zinc passivation shall be used in fabrication of boards.

-

-

-

... More
Note: The following provisions shall be required to be made in the switchboard detailed below

-

-

-

... More
The Switchboard shall have provision for entry of all PVCA cables/bus duct from the top/bottom as required.

-

-

-

... More
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used.

-

-

-

... More
Suitable tinned copper extension links for incoming/outgoing cables shall be provided wherever required

-

-

-

... More
Control circuits includes breaker control switch, auto manual selector switch, anti pumping relay, spring charging trip indication, TIMER, control wiring, Auxiliary contactors MCB’s as required at site.

-

-

-

... More
Positive isolation of all breakers.

-

-

-

... More
All fault level breaking capacity indicates shall be IC.S value at 415 volts (ICS = ICU = ICW = 100%).

-

-

-

... More
Space Heater/ light/air filter shall be provided for each vertical compartment

-

-

-

... More
Padlocking facility shall be provided on all outgoing feeders.

-

-

-

... More
All ACB’s shall have all standard accessories such as CT’s, Arc Chute, Safety Shutters etc.

-

-

-

... More
All inter Panel wiring from PLC to DG / Transformer / Bus Couplers as required.

-

-

-

... More
Link and drops from ACB/MCCB shall be designed for full rated current of ACB/MCCB ratings at same current density as of Main Bus Bar

-

-

-

... More
2 nos. GI earth strip throughout the panel.

-

-

-

... More
MAIN LT PANEL (35 kA)

-

-

-

... More
INCOMING :-

-

-

-

... More
1600 amps 4P electrically operated fully drawout type air circuit breaker as per specification and with following accessories. Transformer Supply Feeder

-

-

-

... More
1250 amps 4P electrically operated fully drawout type air circuit breaker as per specification and with following accessories. DG Supply Feeder-1

-

-

-

... More
800 amps 4P electrically operated fully drawout type air circuit breaker as per specification and with following accessories. DG Supply Feeder-2

-

-

-

... More
Metering & indication for Transformer Supply incoming breaker:

-

-

-

... More
Breaker shall be provided with :

-

-

-

... More
One(1) No. multifunction meter (MFM-1) with Rs- 485 port suitable for measurement of voltage, current, power factor, frequency, Power (kW,kVA, kVAR), Energy (kWH, KVAH, KVARH) and Harmonics (EM-6400 of Conzerv or equivalent).

-

-

-

... More
One (1) set 3 Nos. CTs of ratio 800/5A,15VA, Class 1.0 as required.

-

-

-

... More
One (1) set of 1600/5 A, C.L 1.0 CTs for input to APFC relay.

-

-

-

... More
One set (3 Nos) phase indication lamp with backup SP MCB.

-

-

-

... More
Protection Relays & Interlocking for transformer breaker:

-

-

-

... More
Transformer breaker to be provided with :

-

-

-

... More
One(1) set of multifunctional protection relay suitable for 50, 50N, 51, 51N, 27, 59 and 95. with one set of 800/5 A, 5 P10 CTs .

-

-

-

... More
Metering & Indication For DG supply breakers:

-

-

-

... More
Each Breaker shall be provided with:-

-

-

-

... More
One(1) No. multifuction meter (MFM-1) with Rs- 485 port suitable for measurement of voltage, current, power factor, frequency, hour run, Power (kW,kVA, kVAR), Energy (kWH, KVAH, KVARH) and Harmonics (EM-6400 of Conzerv or equivalent).

-

-

-

... More
One (1) set 3 Nos. CTs of ratio 1250/5A,15VA, Class 1.0 as required.

-

-

-

... More
Volt & Ammeter of battery/Battery charger system as per specification.

-

-

-

... More
Three (3) nos. phase indicating lamps with backup SP MCB.

-

-

-

... More
Load on DG Set indication.

-

-

-

... More
Battery charger and its indication as per specifications.

-

-

-

... More
One no. 12 window Audio/visual annunciator system complete with hooter, Ack, test & Reset PBs for annunciation of low lube oil pressure, high water temperature, Engine over speed, Electrical prot trip, Engine fail to start, low fuel level complete with power supply arrangements.

-

-

-

... More
Micro PLC for load management/automation for 750KVA & 500KVA DG Sets, 1 No. 1000KVA Transformer & 1 No. Bus coupler.

-

-

-

... More
Protection Relays & Interlocking for DG Supply Breaker

-

-

-

... More
Each DG breaker shall be provided with

-

-

-

... More
One(1) set of multifunctional protection relay suitable for 50V, 50N, 51V, 51N, 32, 27, 59 and 95. with one set of 400/5 A, 5 P10 CTs .

-

-

-

... More
Notes :

-

-

-

... More
Above BOQ is for the purpose of scope indentification. However, all items required for sucessful operation, protection inter locks as per operation shceme thru potential free contacts shall be provided in sufficient Nos. as required.

-

-

-

... More
Sufficient No. of contacts terminals shall be provided in the panel as required for necessary remote operation and indications etc.

-

-

-

... More
Operation interlocks as per specification & drawings indicating sufficient nos. of potential free contacts for interlocking/indication annunciation/ control etc shall be provided by the bidder as required.

-

-

-

... More
DG Control System (AMF Panel) :

-

-

-

... More
Each DG breaker Cubicle shall be provided with various components associated with AMF panel and shall comprise of:

-

-

-

... More
The features of AMF logic, Auto/manual/test, start/stop, EM stop operation including 3 attempt start feature, idle running timer, resumption of power supply after some time when EB supply has come back, shall be provided and integrated in the DG breaker cubicle. Set of relays, timer, Aux. Contactor etc as required for meeting the requirement of successful AMF shall be provided.

-

-

-

... More
Notes :

-

-

-

... More
BOQ given above is for a composite panel identifying the scope of supplies. However, bidder shall include all such components as are necessary for a successful and safe AMF scheme in both manual as well as on auto & PLC mode. PLC based DG control panel shall be integrated in the SECTION # 1 & 2.

-

-

-

... More
Above BOQ is only for the purpose of scope identification. However all item required for protection interlocks as per operation scheme through potential free contacts for operation & control shall be provided in sufficient number as required.

-

-

-

... More
Necessary Co-ordination with the DG Vendor for successful operation shall be done by Panel Vendor without any extra cost.

-

-

-

... More
Required interlock should be provided so that transformer and DG supply are not paralleled.

-

-

-

... More
Bus Bar :

-

-

-

... More
2 Nos. 2000A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 35kA. Neutral busbar shall be of 100% capacity.

-

-

-

... More
Aluminium Bus bar with colour coded, heat shrinkable sleeves. (with 100% neutral). Separate earth Bus of 50 x 6 mm Aluminium shall be provided.

-

-

-

... More
Bus Coupler :

-

-

-

... More
One (1) no. 2000 Amps, 415 V, 35kA four pole EDO Bus coupler breaker complete with under voltage and shunt trip release, anti pumping protection, ON/OFF/ indication etc. to be interlocked with the incommers to allow closing of breakers in such a way that either transformer or DG Sets supply can be fed to the buses in all operating condition and necessary interlocking can be achieved as per approved SLD

-

-

-

... More
Outgoings

-

-

-

... More
Each outgoing feeder shall consist of following:

-

-

-

... More
One (1) No. digital multifunction meter for measurement of voltage and currents with selector push buttons and one set of CTS of suitable ratio, CL 1.0, 15 VA.(ELF-3259 of Conzerv or equivalent)

-

-

-

... More
3 Nos. phase indication lamps and 3 Nos. status indication lamps for ON/OFF/ Trip with control SP MCB.

-

-

-

... More
4 Nso. 400 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Microprocessor based release unit for short circuit and over current

-

-

-

... More
1 No. 800 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current without multifunctional meter for capacitor panel.

-

-

-

... More
2 Nos. 315 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Microprocessor based based release unit for short circuit and over current

-

-

-

... More
5 Nos. 250 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current

-

-

-

... More
1 No. 200 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current

-

-

-

... More
2 Nos. 160 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current

-

-

-

... More
4 Nos. 100 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current

-

-

-

... More
Main LT Panel as described above complete with specifications and enclosed SLD

1

-

-

... More
CAPACITOR PANEL 400 kVAR ( 35 kA) Integrated with LT Panel

-

-

-

... More
Incoming

-

-

-

... More
Incoming breaker already taken in LT Panel hence not required here.

-

-

-

... More
3 Set of 800 /5A for , CL-1.0, 15VA measuring CTs for Metering

-

-

-

... More
Square flush mounted digital Ammeter of 96 mm sq. scaled 0-800 amps with 3 way and OFF selector switch

-

-

-

... More
1 Set of phase indicating lamps with MCB.

-

-

-

... More
Terminals to receive XLPE insulated cable

-

-

-

... More
8 step APFCR relay microprocessor based to sense and monitor the system power factor and provide impulses for operation of 6 sequential capacitors circuits

-

-

-

... More
Power factor meter ( digital )

-

-

-

... More
Bus bars

-

-

-

... More
1000A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 35 kA. Neutral busbar shall be of 100% capacity.

-

-

-

... More
Outgoings

-

-

-

... More
4 Nos. 125 A TP MCCB each complete with 150A AC 3 duty TP contactor (suitable for automatic switching of 50 kVAR Capacitor bank) with indicating lamps to give status of circuit , 50 kVAR Hermetically sealed MPP-H type capacitors with fuse protection , discharge resistors , interconnections , set of push buttons red and green for mannual operation of capacitor units , A/M selectors switch etc. as required

-

-

-

... More
4 Nos. 63 A TP MCCB each complete with 80A AC 3 duty TP contactor (suitable for automatic switching of 25 kVAR Capacitor bank) with indicating lamps to give status of circuit , 25 kVAR Hermetically sealed MPP-H type capacitors with fuse protection , discharge resistors , interconnections , set of push buttons red and green for mannual operation of capacitor units , A/M selectors switch etc. as required

-

-

-

... More
4 Nos. 40 A TP MCCB each complete with 50A AC 3 duty TP contactor ( suitable for automatic switching of 15 kVAR Capacitor bank) with indicating lamps to give status of circuit , 15 kVAR Hermetically sealed MPP-H type capacitors with fuse protection , discharge resistors , interconnections , set of push buttons red and green for mannual operation of capacitor units , A/M selectors switch etc. as required

-

-

-

... More
4 Nos. 32 A TP MCCB each complete with 40A AC 3 duty TP contactor ( suitable for automatic switching of 10 kVAR Capacitor bank) with indicating lamps to give status of circuit , 10 kVAR Hermetically sealed MPP-H type capacitors with fuse protection , discharge resistors , interconnections , set of push buttons red and green for mannual operation of capacitor units , A/M selectors switch etc. as required

-

-

-

... More
400 kVAR Capacitor Panel as described above complete with specifications and enclosed SLD

1

-

-

... More
SUB-HEAD IV: 415V MAIN DISTRIBUTION BOARDS

-

-

-

... More
Design, fabrication, assembling, wiring & supply, installation, testing & commissioning of MV Panels fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA painted sheet steel in cubicle formation with reinforcement of suitable size angle iron, channels, T irons, flats wherever necessary for large meter boards. Cable gland plates shall be provided at top and bottom both and windows for meter reading, locking arrangement (pad-lock & seal) with wiring upto KWH meter & meter to MCB shall be done by using adequately rated flexible single core copper wire. The boards shall be treated with all anticorrosive process before painting as per standards with final approved shade of powder coated as approved, 2 nos. earthing terminals shall be provided for all panels. The boards shall be suitable for 415 V, 3 phase, 4 wire, 50 Hz supply system. Boards shall be fabricated in length, height, depth etc to match with site conditions.

-

-

-

... More
An approval shall be taken for each panel before manufacturing. Galvanised hardwares with zinc passivation shall be used in fabrication of boards.

-

-

-

... More
Note: The following provisions shall be required to be made in the switchboard detailed below

-

-

-

... More
The Switchboard shall have provision for entry of all PVCA cables/bus duct from the top/bottom as required.

-

-

-

... More
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used.

-

-

-

... More
Suitable tinned copper extension links for incoming/outgoing cables shall be provided wherever required

-

-

-

... More
Control circuits includes breaker control switch, auto manual selector switch, anti pumping relay, spring charging trip indication, TIMER, control wiring, Auxiliary contactors MCB’s as required at site.

-

-

-

... More
Positive isolation of all breakers.

-

-

-

... More
All fault level breaking capacity indicates shall be IC.S value at 415 volts (ICS = ICU = ICW = 100%).

-

-

-

... More
Space Heater/ light/air filter shall be provided for each vertical compartment

-

-

-

... More
Padlocking facility shall be provided on all outgoing feeders.

-

-

-

... More
All ACB’s shall have all standard accessories such as CT’s, Arc Chute, Safety Shutters etc.

-

-

-

... More
All inter Panel wiring from PLC to DG / Transformer / Bus Couplers as required.

-

-

-

... More
Link and drops from ACB/MCCB shall be designed for full rated current of ACB/MCCB ratings at same current density as of Main Bus Bar

-

-

-

... More
2 nos. GI earth strip throughout the panel.

-

-

-

... More
MDB-1 LIGHTING (Basement-1) (35 Ka)

-

-

-

... More
Incoming #1

-

-

-

... More
1 Nos. 160A, FP MCCB with Micro processor based O/L , S/C and E/F Releases (Ics=100% Icu) and consisting of following

-

-

-

... More
Metering, Indication & Protection:

-

-

-

... More
1 Nos. Voltmeter with VSS

-

-

-

... More
1 Nos. Ammeter

-

-

-

... More
1 Sets supply available indicating lamps with control MCBs.

-

-

-

... More
R-Y-B and ON/OFF indication lamps for incomer

-

-

-

... More
6 Parameter Energy Analyser with Required CTs

-

-

-

... More
Bus Bar:

-

-

-

... More
200A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 35 kA. Neutral busbar shall be of 100% capacity.

-

-

-

... More
Outgoings

-

-

-

... More
5 Nos. 63A, TPN MCCB with thermal magnetic release having overload and short circuit protection and with ON indication lamp . (Ics=100% Icu)

-

-

-

... More
7 Nos. 40A, TPN MCCB with thermal magnetic release having overload and short circuit protection and with ON indication lamp . (Ics=100% Icu)

-

-

-

... More
4 Nos. 25A, TPN MCCB with thermal magnetic release having overload and short circuit protection and with ON indication lamp . (Ics=100% Icu)

-

-

-

... More
MDB -1 LIGHTING (Basement-1) as described above as per SLD

1

-

-

... More
MDB-2 Car Stack Parking (Basement-1)

-

-

-

... More
Incoming

-

-

-

... More
1 No. 400 amps, TP MCCB with thermal magnetic release overcurrent , short circuit and E/F releases with heavy duty solid detachable neutral link complete with on indication lamp

-

-

-

... More
Metering, Indication & Protection:

-

-

-

... More
1 Nos. 6 Parameter Energy Analyser with 3 Nos. Cast Resin CTs and MCBs

-

-

-

... More
Breaker ON OFF indication Lamps

-

-

-

... More
R-Y-B indication lamps with MCBs

-

-

-

... More
Bus Bar:

-

-

-

... More
500 A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 35 kA. Neutral busbar shall be of 100% capacity.

-

-

-

... More
Outgoings:

-

-

-

... More
10 Nos. 63A, TPN MCCB with thermal magnetic release having overload and short circuit protection and with ON indication lamp . (Ics=100% Icu)

-

-

-

... More
MDB-2 Car Stack Parking (Basement-1) as described above as per SLD

1

-

-

... More
STP PANEL

-

-

-

... More
Incomer:

-

-

-

... More
1 Nos.100 A TPN MCCB (25 kA)

-

-

-

... More
One (1) No. digital multifunction meter for measurement of voltage and currents with selector push buttons and one set of CTS of ratio 100A/5A, CL 1.0, 15 VA.

-

-

-

... More
3 Nos. phase indication lamps and 3 Nos. status indication lamps for ON/OFF/ Trip with control SP MCB.

-

-

-

... More
Busbar :

-

-

-

... More
150A TPN Aluminium bus bars of short circuit with stand capacity 25kA & insulated with heat shrinkable,colour coded sleeves.

-

-

-

... More
Outgoing :

-

-

-

... More
2 Nos. DOL Starters,(1 working+1 standby) suitable for 0.314 Kw motor, complete with 10A TP MPCB with thermal range as per Type-II co-ordination chart. (Equalised waste water transfer pump)

-

-

-

... More
1 No. DOL Starters,(1 working+1 standby) suitable for 3.0 Kw motor, complete with 25A TP MPCB with thermal range as per Type-II co-ordination chart. (Waste water Transfer pump from equailzation to Municipal sewer)

-

-

-

... More
2 Nos. DOL Starters,(1 working+1 standby) suitable for 0.75Kw motor, complete with 10A TP MPCB with thermal range as per Type-II co-ordination chart. (Sludge recirculation pump)

-

-

-

... More
2 Nos. DOL Starters,(1 working+1 standby) suitable for 2.0 HP motor, complete with 25A TP MPCB with thermal range as per Type-II co-ordination chart. (Filtr feed pump)

-

-

-

... More
2 Nos. DOL Starters,(1 working+1 standby) suitable for 0.75Kw motor, complete with 10A TP MPCB with thermal range as per Type-II co-ordination chart. (Irrigation water lifting pump)

-

-

-

... More
2 Nos. DOL Starters,(1 working+1 standby) suitable for 2.5 HP motor, complete with 25A TP MPCB with thermal range as per Type-II co-ordination chart. (Flushing water lifting Pump)

-

-

-

... More
2 Nos. DOL Starters,(1 working+1 standby) suitable for 3.73 Kw motor, complete with 25A TP MPCB with thermal range as per Type-II co-ordination chart. (Drainage sump pump-plant room drainage)

-

-

-

... More
2 Nos. DOL Starters,(1 working+1 standby) suitable for 0.75 Kw motor, complete with 10A TP MPCB with thermal range as per Type-II co-ordination chart. (Filter press feed pump)

-

-

-

... More
2 Nos. DOL Starters,(1 working+1 standby) suitable for 11.0 HP motor, complete with 63A TP MPCB with thermal range as per Type-II co-ordination chart. (Air Blower)

-

-

-

... More
1 Nos.20 A DP MCB for UV Sterlizer.

-

-

-

... More
1 Nos.20 A DP MCB for Chlorine doising (0.100Kw)

-

-

-

... More
STP PANEL: described as above and as per SLD

1

-

-

... More
FIRE FIGHTING PANEL

-

-

-

... More
Incomer:

-

-

-

... More
1 Nos.250 A TPN MCCB

-

-

-

... More
Metering, Indication & Protection:

-

-

-

... More
1 Nos. 6 Parameter Energy Analyser with 3 Nos. Cast Resin CTs and MCBs

-

-

-

... More
Breaker ON OFF indication Lamps

-

-

-

... More
R-Y-B indication lamps with MCBs

-

-

-

... More
Busbar :

-

-

-

... More
300A TPN Aluminium bus bars of short circuit with stand capacity 25kA & insulated with heat shrinkable,colour coded sleeves.

-

-

-

... More
Outgoing :

-

-

-

... More
2 Nos. DOL Starters, suitable for 51 Kw motor, complete with 160A TP MPCB with thermal range as per Type-II co-ordination chart. (Fire Pumps)

-

-

-

... More
2 No. DOL Starters, suitable for 6.0 Kw motor, complete with 63A TP MPCB with thermal range as per Type-II co-ordination chart. (Jockey Pump)

-

-

-

... More
1No. 25A DP MCB

-

-

-

... More
1No. 63A TP MCCB

-

-

-

... More
FIRE FIGHTING PANEL: described as above and as per SLD

1

-

-

... More
WTP PANEL

-

-

-

... More
Incomer:

-

-

-

... More
1 Nos.100 A TPN MCCB (25 kA)

-

-

-

... More
Metering, Indication & Protection:

-

-

-

... More
1 Nos. 6 Parameter Energy Analyser with 3 Nos. Cast Resin CTs and MCBs

-

-

-

... More
Breaker ON OFF indication Lamps

-

-

-

... More
R-Y-B indication lamps with MCBs

-

-

-

... More
Busbar :

-

-

-

... More
150A TPN Aluminium bus bars of short circuit with stand capacity 25kA & insulated with heat shrinkable,colour coded sleeves.

-

-

-

... More
Outgoing :

-

-

-

... More
2 Nos. DOL Starters, suitable for 7.0 Kw motor, complete with 40A TP MPCB with thermal range as per Type-II co-ordination chart. (Lifting Pump)

-

-

-

... More
2 Nos. DOL Starters, suitable for 2.0 Kw motor, complete with 25A TP MPCB with thermal range as per Type-II co-ordination chart. (Filter Feed Pump)

-

-

-

... More
4 Nos. DOL Starters, suitable for 2.0 Kw motor, complete with 25A TP MPCB with thermal range as per Type-II co-ordination chart. (Sump Pumps)

-

-

-

... More
1 No. 40A TPN MCCB

-

-

-

... More
1 No. 25A TPN MCCB

-

-

-

... More
WTP PANEL: described as above and as per SLD

1

-

-

... More
MDB-9 UPS PANEL

-

-

-

... More
Incoming

-

-

-

... More
1 Nos. 100A, TPN MCCB with thermal magnetic release having overload and short circuit protection. (Ics=100% Icu)

-

-

-

... More
Metering, Indication & Protection:

-

-

-

... More
Combind digital Ammeter & volt meter , CL-1 CT ratio.

-

-

-

... More
1 Sets supply available indicating lamps with control MCBs.

-

-

-

... More
ON/OFF indication lamps for incomer

-

-

-

... More
Bus Bar:

-

-

-

... More
150A, Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 10 kA. Neutral busbar shall be of 100% capacity.

-

-

-

... More
Outgoings

-

-

-

... More
8 Nos. 40 Amps 4 Pole MCB

-

-

-

... More
MDB-9 UPS PANEL as per above

1

-

-

... More
MDB-10 LIFT PANEL

-

-

-

... More
Incoming:

-

-

-

... More
2 Nos. 200 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with Thermal Magnetic based release for short circuit and over current with 4Pole contactor.

-

-

-

... More
Indications :

-

-

-

... More
Combind digital Ammeter & volt meter , CL-1 CT ratio.

-

-

-

... More
1 Sets supply available indicating lamps with control MCBs.

-

-

-

... More
R-Y-B and ON/OFF indication lamps for incomer

-

-

-

... More
Bus Bars:

-

-

-

... More
250 A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity.

-

-

-

... More
Outgoing

-

-

-

... More
6 Nos. 63A TPN MCCB( Motor Duty)

-

-

-

... More
3 Nos. 40A TPN MCCB( Motor Duty)

-

-

-

... More
MDB-10 LIFT PANEL as described above complete

1

-

-

... More
MDB-3 LIGHT & POWER (SHOPS- GROUND FLLOR)

-

-

-

... More
Incoming:

-

-

-

... More
1 No. 250 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with Thermal Magnetic based release for short circuit and over current

-

-

-

... More
Indications :

-

-

-

... More
Combind digital Ammeter & volt meter , CL-1 CT ratio.

-

-

-

... More
1 Sets supply available indicating lamps with control MCBs.

-

-

-

... More
R-Y-B and ON/OFF indication lamps for incomer

-

-

-

... More
Bus Bars:

-

-

-

... More
300 A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity.

-

-

-

... More
Outgoing

-

-

-

... More
23 Nos. 40 amps 4 pole MCB with 3 phase, keypad based, BIS / BS marked, 10-60 amps prepayment meter along with display unit with Dual register facility as per specification.

-

-

-

... More
4 Nos. 40A 4 Pole MCB

-

-

-

... More
MDB-3 LIGHT & POWER (SHOPS- GROUND FLLOR) as described above complete

1

-

-

... More
MDB-4 LIGHT & POWER (SHOPS- GROUND FLLOR)

-

-

-

... More
Incoming:

-

-

-

... More
1 No. 315 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with Thermal Magnetic based release for short circuit and over current

-

-

-

... More
Indications :

-

-

-

... More
Combind digital Ammeter & volt meter , CL-1 CT ratio.

-

-

-

... More
1 Sets supply available indicating lamps with control MCBs.

-

-

-

... More
R-Y-B and ON/OFF indication lamps for incomer

-

-

-

... More
Bus Bars:

-

-

-

... More
400 A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity.

-

-

-

... More
Outgoing

-

-

-

... More
20 Nos. 40 amps 4 pole MCB with 3 phase, keypad based, BIS / BS marked, 10-60 amps prepayment meter along with display unit with Dual register facility as per specification.

-

-

-

... More
2 Nos. 63 amps 4 pole MCB with 3 phase, keypad based, BIS / BS marked, 10-60 amps prepayment meter along with display unit with Dual register facility as per specification.

-

-

-

... More
3 Nos. 40A 4 Pole MCB

-

-

-

... More
1 No. 63A 4 Pole MCB

-

-

-

... More
MDB-4 LIGHT & POWER (SHOPS- GROUND FLOOR) as described above complete

1

-

-

... More
MDB-5 LIGHT & POWER (SHOPS- FIRST FLOOR)

-

-

-

... More
Incoming:

-

-

-

... More
1 No. 250 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with Thermal Magnetic based release for short circuit and over current

-

-

-

... More
Indications :

-

-

-

... More
Combind digital Ammeter & volt meter , CL-1 CT ratio.

-

-

-

... More
1 Sets supply available indicating lamps with control MCBs.

-

-

-

... More
R-Y-B and ON/OFF indication lamps for incomer

-

-

-

... More
Bus Bars:

-

-

-

... More
300 A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity.

-

-

-

... More
Outgoing

-

-

-

... More
16 Nos. 40 amps 4 pole MCB with 3 phase, keypad based, BIS / BS marked, 10-60 amps prepayment meter along with display unit with Dual register facility as per specification.

-

-

-

... More
1 No. 63 amps 4 pole MCB with 3 phase, keypad based, BIS / BS marked, 10-60 amps prepayment meter along with display unit with Dual register facility as per specification.

-

-

-

... More
3 Nos. 40A 4 Pole MCB

-

-

-

... More
1 No. 63A 4 Pole MCB

-

-

-

... More
MDB-5 LIGHT & POWER (SHOPS- FIRST FLOOR) as described above complete

1

-

-

... More
MDB-6 LIGHT & POWER (SHOPS- FIRST FLOOR)

-

-

-

... More
Incoming:

-

-

-

... More
1 No. 250 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with Thermal Magnetic based release for short circuit and over current

-

-

-

... More
Indications :

-

-

-

... More
Combind digital Ammeter & volt meter , CL-1 CT ratio.

-

-

-

... More
1 Sets supply available indicating lamps with control MCBs.

-

-

-

... More
R-Y-B and ON/OFF indication lamps for incomer

-

-

-

... More
Bus Bars:

-

-

-

... More
300 A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity.

-

-

-

... More
Outgoing

-

-

-

... More
14 Nos. 40 amps 4 pole MCB with 3 phase, keypad based, BIS / BS marked, 10-60 amps prepayment meter along with display unit with Dual register facility as per specification.

-

-

-

... More
4 Nos. 63 amps 4 pole MCB with 3 phase, keypad based, BIS / BS marked, 10-60 amps prepayment meter along with display unit with Dual register facility as per specification.

-

-

-

... More
3 Nos. 40A 4 Pole MCB

-

-

-

... More
1 No. 63A 4 Pole MCB

-

-

-

... More
MDB-6 LIGHT & POWER (SHOPS- FIRST FLOOR) as described above complete

1

-

-

... More
MDB-7 LIGHT & POWER (SECOND FLOOR)

-

-

-

... More
Incoming:

-

-

-

... More
1 No. 400 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with Thermal Magnetic based release for short circuit and over current

-

-

-

... More
Indications :

-

-

-

... More
Combind digital Ammeter & volt meter , CL-1 CT ratio.

-

-

-

... More
1 Sets supply available indicating lamps with control MCBs.

-

-

-

... More
R-Y-B and ON/OFF indication lamps for incomer

-

-

-

... More
Bus Bars:

-

-

-

... More
500 A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity.

-

-

-

... More
Outgoing

-

-

-

... More
3 Nos. 160 amps 4 pole MCB with 3 phase, keypad based, BIS / BS marked, 80-160 amps CT operated prepayment meter along with display unit with Dual register facility as per specification.

-

-

-

... More
6 Nos. 40A TPN MCCB

-

-

-

... More
2 Nos. 63A TPN MCCB

-

-

-

... More
MDB-7 LIGHT & POWER (SECOND FLOOR) as described above complete

1

-

-

... More
MDB-8 LIGHT & POWER (THIRD FLOOR)

-

-

-

... More
Incoming:

-

-

-

... More
1 No. 100 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with Thermal Magnetic based release for short circuit and over current

-

-

-

... More
Indications :

-

-

-

... More
Combind digital Ammeter & volt meter , CL-1 CT ratio.

-

-

-

... More
1 Sets supply available indicating lamps with control MCBs.

-

-

-

... More
R-Y-B and ON/OFF indication lamps for incomer

-

-

-

... More
Bus Bars:

-

-

-

... More
150 A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity.

-

-

-

... More
Outgoing

-

-

-

... More
4 Nos. 40A TPN MCCB

-

-

-

... More
2 Nos. 63A TPN MCCB

-

-

-

... More
MDB-8 LIGHT & POWER (THIRD FLOOR) as described above complete

1

-

-

... More
MDB-12 Ventilation Fanel (Basement-1)

-

-

-

... More
Incoming:

-

-

-

... More
1 No. 315 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with Thermal Magnetic based release for short circuit and over current

-

-

-

... More
Indications :

-

-

-

... More
Combind digital Ammeter & volt meter , CL-1 CT ratio.

-

-

-

... More
1 Sets supply available indicating lamps with control MCBs.

-

-

-

... More
R-Y-B and ON/OFF indication lamps for incomer

-

-

-

... More
Bus Bars:

-

-

-

... More
500 A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity.

-

-

-

... More
Outgoing

-

-

-

... More
18 Nos. 40A TPN MCCB

-

-

-

... More
MDB-12 Ventilation Fanel (Basement-1) as described above complete

1

-

-

... More
PDB-2.1, PDB-2.2, PDB-2.3, PDB-2.4,PDB-2.5, PDB-2.6,PDB-2.7 & PDB-2.8 (8 Nos. PDB) CAR STACK PARKING (BASEMENT-1 & BASEMENT-2)

-

-

-

... More
Incoming:

-

-

-

... More
1 No. 63 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with Thermal Magnetic based release for short circuit and over current

-

-

-

... More
Indications :

-

-

-

... More
Combind digital Ammeter & volt meter , CL-1 CT ratio.

-

-

-

... More
1 Sets supply available indicating lamps with control MCBs.

-

-

-

... More
R-Y-B and ON/OFF indication lamps for incomer

-

-

-

... More
Bus Bars:

-

-

-

... More
100 A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 16 kA. Neutral busbar shall be of 100% capacity.

-

-

-

... More
Outgoing

-

-

-

... More
20 Nos. 20 A 4 Pole MCB'S

-

-

-

... More
PDB-2.1, PDB-2.2, PDB-2.3, PDB-2.4,PDB-2.5, PDB-2.6,PDB-2.7 & PDB-2.8 (8 Nos. PDB) CAR STACK PARKING as described above complete

8

-

-

... More
EXTERNAL FEEDER PILLARs

-

-

-

... More
Design, fabrication, supply , Installation , testing and commisioning of Feeder Pillar fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA sheet in cubicle compartmentalize free standing floor mounted, dust and vermin proof outdoor type double door with reinforcement of suitable size angle iron, channel 'T' irons and / or flats wherever necessary. Cable gland plates shall be provided at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications with 2 coats of PU paint primer and final approved shade of PU paint coating. 2 Nos. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system and with 15% spare space, lifting hooks shall also be provided in case of large panels.

-

-

-

... More
Approval shall be taken for each panel before fabrication. Galvanized hardwares with zinc passivation shall be used in fabrication of panels.

-

-

-

... More
INCOMING

-

-

-

... More
1 no. 63 Amp TPN MCB ( Type C Motor Duty)

-

-

-

... More
1 set of phase indicating lamps with MCB.

-

-

-

... More
BUSBAR

-

-

-

... More
100 Amp FP aluminium busbars (Current Density 1A/Sq.mm) with 100% neutral.

-

-

-

... More
OUTGOING

-

-

-

... More
1 Nos. 32A TPN MCB

-

-

-

... More
3 Nos. 20A DP MCB

-

-

-

... More
1 No. 40A FP MCB Complete with 1 no 24 hrs programmable timer & contactor for automatic operation of external lighting and with 8 nos. 10A/20A/25A amp DP MCB, 10 KA with thermal magnetic protective releases as outgoings for external lighting

-

-

-

... More
Feeder Pillar as Described Above complete.

2

-

-

... More
SUB-HEAD IV: EARTHING

-

-

-

... More
Earthing with copper . Earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.( without charcoal or coke and salt).

6

-

-

... More
Earthing with G.I. Earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt complete as required.

18

-

-

... More
Supply and laying 50mmX6 MM GI strip at 5.0 meter below ground as strip earth electride including soldering etc as required

500

-

-

... More
Supply and laying 50mmX6 MM CU. strip at 5.0 meter below ground as strip earth electride including soldering etc as required

70

-

-

... More
Supply and laying 32mmX5 MM CU strip at 0.50 meter below ground as strip earth electride including soldering etc as required

90

-

-

... More
Supply and laying 32mmX6 MM GI strip at 0.50 meter below ground as strip earth electride including soldering etc as required

400

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

500

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

55

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

300

-

-

... More
LIGHTNING PROTECTION

-

-

-

... More
P/F G.I lightning conductor tape in horixontal run:- Providing and fixing G.I tape 20 mm × 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)

500

-

-

... More
P/F G.I lightning conductor tape in vertical run :- Providing and fixing G.I tape 20 mm × 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For verticla run)

300

-

-

... More
P/F G.I lightning condutor finial :- Providing and fixing of lightning conductor final, made of 25 mm dia 300 long G.I tube, having single prong at top, with 85 mm dia 3 mm thick G.I base plate including holes etc. complete as required.

6

-

-

... More
Reverting, sweating and soldering lightning conductor tape:- Reverting, sweating and soldering of copper/ G.I tape (with another coper/ G.I tape, base of the finial or any other metallic object) as required.

30

-

-

... More
Earthing with G.I. Earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt complete as required.

10

-

-

... More
SUB-HEAD V: TELEPHONE & DATA :

-

-

-

... More
Providing, fixing, connecting and testing of following pair solderless telephonetag block, with powder coated box (Krone make ) of required size box with hinged lockable cover and clamps for dressing of wires etc as required.

-

-

-

... More
200 Pair box

1

-

-

... More
50 Pair box

4

-

-

... More
20 Pair box

4

-

-

... More
10 Pair box

84

-

-

... More
Supply and laying of following 0.61mm dia annealed tinned copper conductor PVC insulated and PVC sheathed unarmoured telephone cable in existing conduit in concealed/ surface system complete as required

-

-

-

... More
200 pair Cable

50

-

-

... More
50 pair Cable

200

-

-

... More
20 pair Cable

150

-

-

... More
5 pair Cable

2500

-

-

... More
2 pair Cable

100

-

-

... More
Providing, fixing, connecting, testing and commisssioning of zinc passivated box with moulded plate in recess or on surface moulded type with following including all necessary materials etc. as required.

-

-

-

... More
2 Pair telephone cord outlet (RJ-11)

5

-

-

... More
TV antina Socket outlet

5

-

-

... More
Supply and fixing 1 or 2 module ( 75mm X 75mm ) GI Box along with modular base and cover plate for modular switches in recess etc as required

85

-

-

... More
Supply and fixing of Computer terminal (RJ-45) outlet in existing box with modular plate

5

-

-

... More
Supplying and fixing of following size medium class PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.

-

-

-

... More
20mm dia

50

-

-

... More
25mm dia

100

-

-

... More
32mm dia

50

-

-

... More
Providing and fixing of UTP CAT 6 Computer LAN Cable With Star Separator in existing conduits .

50

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

50

-

-

... More
SUB-HEAD VI: INTERNAL WIRING AND FINAL DISTRIBUTION BOARDS

-

-

-

... More
WIRING IN PVC CONDUITS

-

-

-

... More
Wiring for Light point / Fan point / Exhaust Fan point / Call Bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed Medium Class PVC conduit , with modular switch ,modular plate ,suitable GI box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
a) Group - C

175

-

-

... More
Wiring for twin controlled light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed Medium Class PVC conduit , with 2 way modular switch ,modular plate ,suitable GI box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.

6

-

-

... More
Wiring for light/ceiling fan/exhaust fan/call bell point with 2x1.5 sq.mm PVC insulated stranded copper conductor cable alongwith 1 No. 1.5 sq.mm PVC insulated copper conductor cable for earthing in PVC Medium conduit as required. (Point shall be controlled / looped From existing point).

380

-

-

... More
Wiring with 2 x 2.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed Medium Class PVC conduit alongwith 1 No. 2.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For 5A primary Socket and 16A Secondary Socket)

200

-

-

... More
Same as above but in existing conduits / Raceways

50

-

-

... More
Wiring with 2 x 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed Medium Class PVC conduit alongwith 1 No. 1.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For 5A Secondary Points)

300

-

-

... More
Same as above but in existing conduits / Raceways

10

-

-

... More
Wiring for light / power plug point with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC Medium Class conduit alongwith 1 No. 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For 16A Socket)

1800

-

-

... More
Same as above but in existing conduits / Raceways

10

-

-

... More
DB SUBMAIN WIRING IN PVC CONDUITS

-

-

-

... More
Wiring for DB submain with 4 x 10 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed Medium Class PVC conduit alongwith 2 No. 10sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.

10

-

-

... More
Wiring for DB submain with 4 x 6 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed Medium Class PVC conduit alongwith 2 No. 6 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.

10

-

-

... More
Wiring for DB submain with 2 x 6 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed Medium Class PVC conduit alongwith 1 No. 6 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.

10

-

-

... More
Wiring for DB submain with 2 x 10 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed Medium Class PVC conduit alongwith 1 No. 10 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.

10

-

-

... More
POWER SOCKETS

-

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 3 pin 5 / 6 amps modular socket outlet and 5 / 6 amps modular switch,connection,painting etc.as required.

10

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 6 pin 15 / 16 modular socket outlet and 15 / 16 amps modular switch,connection,painting etc.as required.

65

-

-

... More
Supplying and fixing modular type 25 amps A.C. unit box with ON/OFF MCB on surface or in recess complete with connections, testing and commissioning etc as required

2

-

-

... More
Geyser/ Toilet Inline Fan point consisting of following :- - 1 No. 6 pin No 6/16A Modular Socket in 2 Module Box with modular Plate near Geyser - 1 No 6/16A Modular Switch in 2 Module Box with Modular plate near entry at switch board level - Wiring between Socket and Switch board with 3 Nos. 4.0 Sq. mm Cu Wire in conduit including connections at both ends

1

-

-

... More
Supplying and fixing 63 amps, 415 volts, 4 Pole MCB Isolator in sheet steel enclosure, on surface or in recess, complete with connections, testing and commissioning etc. as required.

12

-

-

... More
Supplying and fixing 40 amps, 415 volts, 4 Pole MCB Isolator in sheet steel enclosure, on surface or in recess, complete with connections, testing and commissioning etc. as required.

32

-

-

... More
Supplying and fixing 25 amps, 415 volts, 4 Pole MCB Isolator in sheet steel enclosure, on surface or in recess, complete with connections, testing and commissioning etc. as required.

45

-

-

... More
FINAL DISTIRIBUTION BOARD

-

-

-

... More
i) 1 No. 40 Amps 4P MCB Isolator

-

-

-

... More
ii) 1 No. 40 Amps 2P RCCB -3Nos

-

-

-

... More
iii) 18 Nos. 6-32 Amps SP MCBs as outgoing

18

-

-

... More
A. TP and N D.B ( DOUBLE DOOR HORIZONTAL TYPE) i) 1 No. 40 Amps 4P MCB Isolator ii) 1 No. 40 Amps 2P RCCB -3Nos iii) 12 Nos. 6-32 Amps SP MCBs as outgoing

6

-

-

-

-

-

... More
Supplying,installation,testing and commissioning of online double conversion fully microprocessor based ,indoor type, compact UPS system with IGBT based PWM technology within built isolation transformer to achieve THD5% and input power factor of greater than 0.95 at 50% loading, suitable for Single phase AC input voltage 380V to 450V, 50Hz+3%/-3%and single phase AC out put voltage 415±1% volts & frequency 50 ± 0.5 Hz , necessary VRLA batteries of suitable size having 30 minutes backup time and suitable size connecting cable(forUPS to Battery and battery to battery), static and maintenance bypass switch, SNMP card for RS232/ ethernet IP computability for operation and monitoring etc. with all components asmentioned in BOQ, specifications and schedule, complete etc. as required. Note:Concerning vendor needs to furnish the battery sizing calculations at the time of GA approval and battery size has to be as per the approved GA drawing.

-

-

-

... More
15KVA UPS with 30min battery backup of 3phase input &3phase output.

1

-

-

... More
12 volt 65Ah sealed maintence free(SMF) battery with 24 month replacement guarinty

20

-

-

... More
Battery Rack :

-

-

-

... More
MS battery rack suitable for 15-20 Ups battery installation.

1

-

-

... More
Supply and installation of 300 mm, 230 v A.C. exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required.

8

-

-

... More
Extra for fixing the louvers/ shutters complete with Frame for a exhaust fan of all sizes

8

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel at least 2 mm thick, vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

4

-

-

... More
Constructing brick chamber with cover for cable entry of following sizes inside dimension) with cement concrete above work in cement mortar 1:5 (1 cement : 5 coarse sand) including making necessary notch for lighting the cover necessary excavation 10cm thick foundation concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) and inside and outside plastering with cement mortar 1:3 (1 cement and 50% coarse sand) with floating coat of neat cement finish complete as per requirement.

-

-

-

... More
600 mm X600 mm X 750mm Deep Man hole

4

-

-

... More
450 mm X450mm X 600mm Deep Man hole

5

-

-

... More
Supply installation testing & commissiong Of KP-8328 Pelican Orna Florian Lighting Pole, Ht.7300, Customized to 7 meter height pole. Height to accomodate the looping type cable end box, Single pole MCB with mounting channel Integral in - built flush door consisting of 4 Way connector for incoming and outdoing cable including excabation and refilling etc complete as required (Make: K-Lite or equivalent.)

15

-

-

... More
SITC of KP-9206 Foundation Bolt, 4 Nos of M20 x 500 mm bolt with 2 Nuts & 2 Washer complete as required.

15

-

-

... More
SITC of KL-6791 Pelican Fort, Dimension : A9 : Ø634 x 618, A11 : Ø634 x 412, A12 : Ø634 x 610, Wattage : 1 x 50W LED complete with all accesries as required. (Make: K-Lite or equivalent.)

15

-

-

... More
Supply installation testing & commissioning of KP-4340 Causeway Lighting Pole, Ht.4270 Customized to 4 meter height poleHeight to accomodate the looping type cable end box, Single pole MCB with mounting channel Integral in - built flush door consisting of 4 Way connector for incoming and outdoing cable including excabation and refilling etc complete as required (Make: K-Lite or equivalent.)

4

-

-

... More
SITC of KP-9204 Foundation Bolt, 4 Nos of M16 x 300 mm bolt with 2 Nuts & 2 Washer complete as required.

4

-

-

... More
SITC of KL-4932 Magudam Midi, Dimension : Ø350 x 680, Wattage : 30W LED complete with all accesries as required(Make: (K-Lite or equivalent.).

4

-

-

... More
LT cables

-

-

-

... More
2 core, 6.0 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor

125

-

-

... More
2 core, 10 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor

90

-

-

... More
2 core, 16 sq. mm XLPE/PVC insulated sheathed (Heavy duty) armoured electrical cable with aluminium conductor

150

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade size not exceeding 35Sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

155

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade size not exceeding 35 Sqmm direct in ground horizontal formation in the same trench including excavation, sand cushioning, protective covering and refilling the trench etc as required.

165

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade size not exceeding 35Sqmm in the existing RCC/ HUME/ METAL pipe as required.

45

-

-

... More
DSR 2018 Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.

-

-

-

... More
2C x 6 sq mm

14

-

-

... More
2C x 10 sq mm

12

-

-

... More
2C x 16 sq mm

8

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required.

750

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.

4

-

-

... More
Supplying and fixing 50mm dia GI pipe on the pole for cable entry to junction box as required.

120

-

-

... More
Wiring with 2 x 2.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 2.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required

90

-

-

... More
Wiring with 2 x 4.0 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 4.0 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required

50

-

-

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.

-

-

-

... More
SOR 3.3.6.1 100 mm dia

50

-

-

... More
SOR 3.3.6.1 150 mm dia

75

-

-

... More
Total of Subhead-VIII Carried to Summary

-

-

-

... More
SUB-HEAD IX: INTERNAL LIGHTING FIXTURE

-

-

-

... More
Supplying and fixing reccessed mounted 6/7 W LED vertical down lighter complete with all accesories and replacable electronic driver and directly on false ceiling including connection with 1.5 sq . Mm FR PVC insulated copper conductor and earthing the body as reqd.

85

-

-

... More
Supplying and fixing reccessed mounted 12 W LED vertical down lighter complete with all accesories and replacable electronic driver and directly on false ceiling including connection with 1.5 sq . Mm FR PVC insulated copper conductor and earthing the body as reqd.

208

-

-

... More
Supplying and fixing 20/22 W LED type batten fitting complete with electronic driver and LED tube directly on wall / ceiling including connection with 1.5 sq . Mm FR PVC insulated copper conductor and earthing the body as reqd.

121

-

-

... More
Supplying and fixing Surface mounted 10/12 watt LED type Bulk-head fitting comprising of pressure die cast housing with acrylic diffuser (IP65) and complete with integrated electronic driver etc directly on wall/ceiling including connection with 1.5 sq.mm FR PVC insulatedcopper conductor cable and earthing the body etc. as required..

15

-

-

... More
Supplying and fixing Surface mounted 15/16 watt LED downlighter complete with integrated electronic driver & LED directly on ceiling including connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc. as required.

100

-

-

... More
Total of Subhead-VIII Carried to Summary

-

-

-

... More
SUB-HEAD-IX :FIRE ALARM AND DETECTION SYSTEM

-

-

-

... More
DSR 2018 Supplying and fixing of following sizes of steel conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.

-

-

-

... More
1.20.2 25mm dia M.S. conduit.16 SWG M.S. conduit

2550

-

-

... More
32mm dia M.S. conduit.16 SWG M.S. conduit

200

-

-

... More
Supplying and laying of following sizes FRLSLS PVC insulated single core copper wire in existing conduit complete as required.

-

-

-

... More
2x1.5 sq mm

3000

-

-

... More
2x2.5 sq mm

175

-

-

... More
DSR 2018 Supplying, installing, testing and commissioning of the following as per specification complete with junction box, as and where required.

-

-

-

... More
Analogue addressable Photo Electric type Smoke Detector with mounting base, address switch complete as required.

173

-

-

... More
Analogue addressable rate of rise cum fixed temperature thermistor type heat detector with mounting base, address switch complete as required.

204

-

-

... More
Addressable type Manual Call Point complete as required.

25

-

-

... More
Addressable Hooter cum strobe complete as required.

25

-

-

... More
Duct casting unit with casing of fabricated aluminium/poly carbonate and hinged inspection cover, 1 No. inlet of proper length & 1 no. outlet tube & with 1 no. analogue addressable photoelectric type Smoke detector with mounting base, address switch complete as required.

2

-

-

... More
Analogue addressable Fault Isolators for isolating shorted, de-wired and loose circuits between two successive Fault isolators with automatic resetting arrangement. (max. 20 devices for one fault isolators).

18

-

-

... More
Analogue addressable, automatic commandable Control Switches for switching on/off various ventilation fans, pressurisation fans, zones of speakers etc. and other Fire operation related devices and complete as required.

20

-

-

... More
Addressable Input Card/monitor module for connecting to Flow Switch etc.

25

-

-

... More
DSR 2018Providing, installing, connecting, testing and commissioning of micro processor based Logic driven Analogue Addressable Panel for below mentioned loops (each loop accessing 120 addressable detectors & 120 addressable devices). The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all control switches whenever any alarm is triggered. The Panel shall have its own integrated PA System having amplifiers suitable for given no. of speaker & minimum 12 zone selector channels and have sealed maintenance free batteries of required AH capacity of 24 volts capable of running for 24 hours in normal condition followed by 60 minutes in Alarm condition with battery charger, rectifier, Loop cards, Keypad operation, L C D unit to indicate Fire / Fault Signal of individual unit, built in /external printer to log all incoming data etc complete in all respects. Software for one work station on which all graphics etc. can be viewed and providing a communication interface to the same workstation. The panel shall be provided with communication card for third party integration.

-

-

-

... More
Panel shall have programmable switch plates for controlling horn strobe zones/AHU shut off etc. from panel itself. Panel shall have inbuilt autodialer with minimum 6 line output. Panel shall have its own master fire fighting telephone/audio control/command centre.

-

-

-

... More
The Panel shall also have Logic hardware and software built into it for initiating specific AHU tripping, time delay operation of strobe, subsequent operation of electronic speakers, and finally hooters.

-

-

-

... More
2 loop panel

1

-

-

... More
Notes :

-

-

-

... More
Each loop of fire alarm panel shall have 10 to 15% spare addressable units.

-

-

-

... More
At all panels global access to be provided.

-

-

-

... More
Information of all the panel shall be accessible from any of panels through networking.

-

-

-

... More
All panels shall be upgradable to minimum 25% more loops.

-

-

-

... More
Other requirements are given in the specifications.

-

-

-

... More
The no. of loops may be changed based on the loop capacity of the panel.

-

-

-

... More
2 loop card.*

1

-

-

... More
Providing, installing, testing and commissioning of zero loop Repeater Panel for Fire Alarm System with piezo sounder, LCD alpha numeric character display with accept/reset buttons for alarm address of any sensor/field device. The Repeater Panel shall provide field device address as required. The Repeater Panel shall be active & all the setting for fire alarm system can be configured with panel.

1

-

-

... More
DSR 2018 PUBLIC ADDRESS SYSTEM :

-

-

-

... More
Wall mounted speaker with three tap changers in acoustically treated box with speaker and line matching transformer (2W max).(For car park & double height areas)

75

-

-

... More
Ceiling mounted baffle speaker with three tap changers (2W).

40

-

-

... More
Fire Fighter Telephone System :

-

-

-

... More
Portable UL listed fire phone handsets in a suitable enclosure.

8

-

-

... More
Addressable fire phone jack plates with control/monitor module.

25

-

-

... More
CENTRAL CONTROL STATIONS :

-

-

-

... More
Supplying, installing, testing and commissioning of the Central Control Stations consisting of the following:

-

-

-

... More
Intel Core-i7 machine.

1

-

-

... More
Colour Monitor 24 inch.

1

-

-

... More
Laser Printer

1

-

-

... More
Mouse, Keyboard etc.

1

-

-

... More
Supply, installation, testing and commissioning of UL listed software for Remote programming of Fire Detection and Alarm System through central control station. The software shall be capable of the following function including licence as per specification.

-

-

-

... More
Uploading and downloading of information to FACP

-

-

-

... More
Graphics including autocad drawings.

-

-

-

... More
Detectors information and change of detectors setting.

-

-

-

... More
Software as described above.

1

-

-

... More
SUB HEAD-XI CCTV SYSTEM

-

-

-

... More
CCTV- Internal & External Works

-

-

-

... More
CCTV & Recording

-

-

-

... More
Supply, installation, testing and commissioning of IP based Fixed indoor veri focal lences auto iris cameras 1.3 MP including integrated housing (dome type), Connectors, A.I.Lens, Camera Mounts,Power Supply and all Ancillary Equipment & all accessories.Panasonic/Honeywell/Axis

50

-

-

... More
Supply, installation, testing and commissioning of IP based Fixed veri focal lenses auto iris 1.3 MP cameras including integrated housing (Bullet type), Connectors, A.I.Lens, Camera Mounts,Power Supply and all Ancillary Equipment & all accessories.Panasonic/Honeywell/Axis

22

-

-

... More
Supply, laying, termination and testing of 32" LED TV( Full HD) with wall mounting kit and including all other accessories as required,LG/Samsung/benq

5

-

-

... More
Supply, laying, termination and testing of 8 Port POE switch including all other accessories as requiredCisco/Linksys/HP

4

-

-

... More
Supply and Laying of Cat-6 Cable in existing conduits for Cameras,Molex/Comscope/Belden

3000

-

-

... More
Supply and Laying of 3C-2.5 Sq. mm unarmoured Power Cable in existing conduits for Cameras power supply, Polycab/ KEI/ Havells/ Anchor/ Equivalent

2500

-

-

... More
Conduits

-

-

-

... More
Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.

-

-

-

... More
20mm dia

1500

-

-

... More
25mm dia

750

-

-

... More
32mm dia

350

-

-

... More
External Building CCTV & Recording

-

-

-

... More
Supply, installation, testing and commissioning of IP Based outdoor Pan/Tilt/Zoom cameras including integrated Housing , Connectors, Lens, Camera Mounts,Power Supply , PTZ ket board controller and all Ancillary Equipment & all accessories including Remote Reciever Unit and Pan Tilt Unit (including driver cables), Panasonic/ Honeywell/ Axis/ Equivalent

-

-

-

... More
Wall / Ceiling mounted

3

-

-

... More
Supply, installation, testing and commissioning of IP based Fixed veri focal lences auto iris 1.3 MP cameras including integrated housing (Bullet type), Connectors, A.I.Lens, Camera Mounts,Power Supply and all Ancillary Equipment & all accessories.Panasonic/Honeywell/Axis/Equivalent

9

-

-

... More
Supply, installation, testing and commissioning of 32 input duplex multiplexer with 2 video outputs with suitable Hard Disk facility recording(30 Days Backups) including all controllers/ software etc as required for above cameras( 32 Channel NVR),Panasonic/Honeywell/Axis/Equivalent

2

-

-

... More
Supply, installation, testing and commissioning of 32u Rack with accessories ( 800/1000) Net Rack Shelf Full Tray (6 Nos.), 2 No. Vertical Power Manager with Cooling Fan Tray etc as required,Netrack/GEPL/Delta

2

-

-

... More
Supply, laying, termination and testing of 32" LED TV( Full HD) with wall mounting kit and including all other accessories as required,LG/Samsung/benq/Equivalent

4

-

-

... More
Supply, laying, termination and testing of 24 Port POE switch including all other accessories as required,Cisco/Linksys/HP

2

-

-

... More
Supply, laying, termination and testing of 8 Port POE switch including all other accessories as required,Cisco/Linksys/HP/Equivalent

4

-

-

... More
Supply and Laying of Cat-6 Cable in existing conduits for Cameras,Molex/Comscope/Belden

2200

-

-

... More
Supply and Laying of Optical fibre 6 Core Single mode cable ( Finolex or Equal make)Molex/Comscope/Belden/Equivalent

1000

-

-

... More
Supply and Laying of 63mm HDPI pipe with all accessories for laying fibre/ cable in outdoor areas.Gamson/Equivalent

700

-

-

... More
Supply , Installation , testing and commisioning of all accessories to complete the CCTV system integration like Jack Panels , Giga Byte switches , weatherproof racks , Indoor type racks with power manager , sintex boxes for POE switches , OFC to RJ-45 Media convertor , LIU boxes etc with all software as required for above cameras

1

-

-

... More
Supply , Installation , testing and commisioning of 6 kVA UPS ( 1 Phase input and 1 Phase output) with 30 Minutes back up complete with batteries etc.APC/Libert/Eaton/Equivalent

1

-

-

... More
Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.

-

-

-

... More
1.21.1 Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification. 20mm dia

400

-

-

... More
1.21.2 Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification. 25mm dia

400

-

-

... More
1.21.3 Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification. . 32mm dia

250

-

-

... More
Main backdrop screen of size 5000mm X 3000mm having 16mm pixel pitch Outdoor LED Screen, having 3 in1 SMD based Full color LED Display with 1.6~3.2mm thick RGB Chip having high contrast with dark Chip back,each module having size of 576mm X 576mm with resolution of each module having less watt per m2 consumption of power ,having IP 65 rating rugged sealed front , excellent image clarity and very less response time (Outdoor LED system for the Stage Backdrop system )LCF/Mitsubishi/Sol Colour,16mm Pixel Pitch

-

-

-

... More
HDMI1.4, VGA, DVI, DP1.1 + Ethernet + RS-232 + bidirectional IR standalone HDBaseT transmitter forCATx cable. HDCP, 3D and 4K /UHD(30Hz RGB4:4:4 , 60Hz YCbCr 4:2:0) support. 170m extension distance. Stereo local analog audio embedding, GPIO control port, command injection, Autoselect & priority modes, EDID Management. Compatible with 'TPS' series input boards and receivers.(Digital Signal Extenders )Lightware /Extron/Crestron/Equivalent

1

-

-

... More
HDMI1.4, VGA, DP1.1 + Ethernet + RS-232 + bidirectional IR HDBaseT wallplate transmitter forCATx cable. HDCP, 3D and 4K / UHD(30Hz RGB4:4:4 , 60Hz YCbCr 4:2:0) support. 170m extension distance. US2- gang wall box size. Compatible with TPS series input boards and receivers.(Digital Signal Receivers)Lightware /Extron/Crestron/Equivalent

1

-

-

... More
Installation & Integration Charges (Installation & Integration)GEPL/Vector/Innov/Custom

1

-

-

... More
Programming and Software Customization Solution (Programming & Customization)GEPL/Vector/Innov/Custom/Equivalent

1

-

-

... More
HVAC WORK

-

-

-

... More
AXIAL FAN [EXHAUST AIR] :

-

-

-

... More
Supply, installation, testing, commissioning of tube/vane axial flow fan, consisting of motor, drive arrangement, base frame, supporting arrangement, vibration isolator and accessories as per specification & drawings. Motor shall be of high temp. resistance class 'H'.

-

-

-

... More
Air Qty in Total Static Pressure Approx. Fan CFM in mmWg motor kW

-

-

-

... More
Normal Exhaust

-

-

-

... More
Car Parking Basements

-

-

-

... More
18200cfm 30 7.5

1

-

-

... More
23000cfm 30 7.5

1

-

-

... More
16000cfm 30 7.5

1

-

-

... More
20000cfm 30 7.5

1

-

-

... More
Plant rooms (STP, WTP & LT Panel Room)

-

-

-

... More
2300cfm 30 0.75

1

-

-

... More
2600cfm 30 0.75

2

-

-

... More
Smoke Exhaust (in case of fire)

-

-

-

... More
Car Parking Basements

-

-

-

... More
18200cfm 30 7.5

1

-

-

... More
23000cfm 30 7.5

1

-

-

... More
16000cfm 30 7.5

1

-

-

... More
20000cfm 30 7.5

1

-

-

... More
Cinemas & Food Court

-

-

-

... More
25000cfm 25 7.5

2

-

-

... More
14500cfm 25 5.5

1

-

-

... More
AXIAL FAN [FRESH AIR] :

-

-

-

... More
Supply, installation, testing, commissioning of tube/vane axial flow fan, consisting of motor, drive arrangement, base frame, supporting arrangement, vibration isolator and accessories as per specification & drawings.

-

-

-

... More
Air Qty in Total Static Pressure Approx. Fan CFM in mmWg motor kW

-

-

-

... More
Normal Fresh Air

-

-

-

... More
Car Parking Basements

-

-

-

... More
18200cfm 30 7.5

1

-

-

... More
23000cfm 30 7.5

1

-

-

... More
16000cfm 30 7.5

1

-

-

... More
20000cfm 30 7.5

1

-

-

... More
Plant rooms (STP, WTP & LT Panel Room)

-

-

-

... More
2300cfm 30 0.75

1

-

-

... More
2600cfm 30 0.75

2

-

-

... More
Fresh Air (in case of fire)

-

-

-

... More
Car Parking Basements

-

-

-

... More
18200cfm 30 7.5

1

-

-

... More
23000cfm 30 7.5

1

-

-

... More
16000cfm 30 7.5

1

-

-

... More
20000cfm 30 7.5

1

-

-

... More
Cinemas & Food Court

-

-

-

... More
25000cfm 25 7.5

2

-

-

... More
14500cfm 25 5.5

1

-

-

... More
Liftwell Pressurisation

-

-

-

... More
9500cfm 25 5.5

2

-

-

... More
14000cfm 25 5.5

1

-

-

... More
Cabinet Fan for Toilet Exhaust

-

-

-

... More
Supply, installation, testing & commissioning of DOUBLE SKIN, FLOOR MOUNTED, Sectionalized construction, outdoor construction, Ventilation Unit as per specifications and complete with the following:

-

-

-

... More
Fan section with DIDW Centrifugal fan, AMCA certified high efficiency fan, Forward Curved blower with fire retardant canvass connection at fan inlet.

-

-

-

... More
High efficiency 'EF1' squirrel cage induction motor suitable for 415±10% volts, 50±3%Hz, 3 phase AC supply. Motor shall be suitable for VFD operation. It shall be complete with V-Belt drive package.

-

-

-

... More
Fan & motors shall be mounted on a common base frame with motor sliding rails & complete base frame mounted on the Ventilation Unit casing with vibration isolation spring isolators.

-

-

-

... More
Air Qty in Total Static Pressure Approx. Fan CFM in mmWg motor kW

-

-

-

... More
5500cfm 30 5.5

1

-

-

... More
3500cfm 30 3.7

1

-

-

... More
FLEXIBLE CANVASS CONNECTIONS

-

-

-

... More
Supply, installation, testing & commissioning of 2 hours fire rated flexible canvass fan outlet connections with suitable flanges on both the faces.

-

-

-

... More
The canvas connection shall have circular flange on the fan side & square flange of the same size as of fan dia on the other side. Flanges shall be heavy duty 'MS' with nuts & bolts & fire retardant sealing / gas keting.

-

-

-

... More
Canvas connection for 400 mm fan dia

12

-

-

... More
Canvas connection for 630 mm fan dia

2

-

-

... More
Canvas connection for 800 mm fan dia

18

-

-

... More
Canvas connection for 900 mm fan dia

16

-

-

... More
Canvas connection for 1000 mm fan dia

14

-

-

... More
BACK DRAFT DAMPER / GRAVITY LOUVERS

-

-

-

... More
Supply, installation, testing & commissioning of fan discharge / outlet back draft dampers of heavy gauge GSS Construction complete with frame & necessary civil work for fixing.

-

-

-

... More
Gravity Louver for 800 mm fan dia

2

-

-

... More
Gravity Louver for 900 mm fan dia

2

-

-

... More
Gravity Louver for 1000 mm fan dia

3

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.

-

-

-

... More
16.12.1.1 Thickness 0.63 mm sheet

325

-

-

... More
16.12.1.2 Thickness 0.8 mm sheet

100

-

-

... More
16.12.1.3 Thickness 1.00 mm sheet

1200

-

-

... More
Thickness 1.25 mm sheet

520

-

-

... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.

-

-

-

... More
16.12.2.1 Thickness 0.63 mm sheet

50

-

-

... More
Thickness 0.8 mm sheet

25

-

-

... More
Thickness 1.00 mm sheet

25

-

-

... More
Thickness 1.25 mm sheet

25

-

-

... More
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications.

2

-

-

... More
16.15 Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

16

-

-

... More
16.16 Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

18

-

-

... More
Supply, installation, testing & commissioning of Extruded aluminum exhaust air/fresh air louvers without GI Bird Screen as per specifications. The louvers shall be anodized aluminum as per apporval of the Architect and offering free area not less than 60% of gross face area.

9

-

-

... More
Supply, installation, testing & commissioning of Ventilation Fan Starter Panels in steel sheet enclosure complete with all accessries as required.

-

-

-

... More
VENTILATION FAN STARTER PANELS

-

-

-

... More
8 Nos. DOL Starters, suitable for 7.5 Kw motor, complete with 40A TP MPCB with thermal range as per Type-II co-ordination chart. (Axial Flow Fan-Normal Exhaust/Fresh Air Fan)

-

-

-

... More
8 Nos. DOL Starters, suitable for 7.5 Kw motor, complete with 40A TP MPCB with thermal range as per Type-II co-ordination chart. (Axial Flow Fan- Smoke Exhaust/Replenishment Air Fan)

-

-

-

... More
2 Nos. DOL Starters, suitable for 0.75Kw motor, complete with 10A TP MPCB with thermal range as per Type-II co-ordination chart. (Axial Flow Fan-Normal fresh Air/Normal Exhaust Air-Pump Room)

-

-

-

... More
2 Nos. DOL Starters, suitable for 0.75Kw motor, complete with 10A TP MPCB with thermal range as per Type-II co-ordination chart. (Axial Flow Fan-Normal fresh Air/Normal Exhaust Air-STP)

-

-

-

... More
2 Nos. DOL Starters, suitable for 7.5Kw motor, complete with 40A TP MPCB with thermal range as per Type-II co-ordination chart. (Axial Flow Fan-Make up fresh Air/SmokeExhaust - Theater-1)

-

-

-

... More
2 Nos. DOL Starters, suitable for 7.5Kw motor, complete with 40A TP MPCB with thermal range as per Type-II co-ordination chart. (Axial Flow Fan-Make up fresh Air/SmokeExhaust - Theater-2)

-

-

-

... More
2 Nos. DOL Starters, suitable for 5.5Kw motor, complete with 25A TP MPCB with thermal range as per Type-II co-ordination chart. (Axial Flow Fan-Make up fresh Air/SmokeExhaust - Audi Food Court)

-

-

-

... More
3 Nos. DOL Starters, suitable for 5.5Kw motor, complete with 25A TP MPCB with thermal range as per Type-II co-ordination chart. ( Pressurization Axial Flow Fan-Passenger Lift Well-1,2 & Service Lift Well-1)

-

-

-

... More
VENTILATION FAN STARTER PANELS described as above and as per SLD

1

-

-

... More
AXIAL FAN [EXHAUST AIR] :

-

-

-

... More
Supply, installation, testing, commissioning of tube/vane axial flow fan, consisting of motor, drive arrangement, base frame, supporting arrangement, vibration isolator, gravity louver and accessories as per specification & drawings. Motor shall be of high temp. resistance class 'H'.

-

-

-

... More
Air Qty in Total Static Pressure Approx. Fan CFM in mmWg motor kW

-

-

-

... More
Normal Exhaust

-

-

-

... More
Municipal Pump Room

-

-

-

... More
16500cfm 30 7.5

1

-

-

... More
AXIAL FAN [FRESH AIR] :

-

-

-

... More
Supply, installation, testing, commissioning of tube axial flow fan, consisting of motor, drive arrangement, base frame, supporting arrangement, vibration isolator, gravity louver and accessories as per specification & drawings.

-

-

-

... More
Air Qty in Total Static Pressure Approx. Fan CFM in mmWg motor kW

-

-

-

... More
Normal Fresh Air

-

-

-

... More
Municipal Pump Room

-

-

-

... More
16500cfm 30 7.5

1

-

-

... More
FLEXIBLE CANVASS CONNECTIONS

-

-

-

... More
Supply, installation, testing & commissioning of 2 hours fire rated flexible canvass fan outlet connections with suitable flanges on both the faces.

-

-

-

... More
The canvas connection shall have circular flange on the fan side & square flange of the same size as of fan dia on the other side. Flanges shall be heavy duty 'MS' with nuts & bolts & fire retardant sealing / gas keting.

-

-

-

... More
Canvas connection for 800 mm fan dia

2

-

-

... More
16.12.1.1 Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet

25

-

-

... More
16.12.1.2 Thickness 0.8 mm sheet

125

-

-

... More
16.12.1.3 Thickness 1.00 mm sheet

80

-

-

... More
16.12.2.1 Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet

20

-

-

... More
16.15 Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

3

-

-

... More
16.16 Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

3

-

-

... More
Supply, installation, testing & commissioning of Extruded aluminum exhaust air/fresh air louvers without GI Bird Screen as per specifications. The louvers shall be anodized aluminum as per apporval of the Architect and offering free area not less than 60% of gross face area.

6

-

-

... More
Supply, installation, testing & commissioning of Ventilation Fan Starter Panels in steel sheet enclosure complete with all accessries as required. VENTILATION FAN STARTER PANELS 2 Nos. DOL Starters, suitable for 7.5Kw motor, complete with 40A TP MPCB with thermal range as per Type-II co-ordination chart. (Axial Flow Fan-Normal fresh Air/Normal Exhaust Air- City Water Pump Room)

1

-

-

... More
Add 12 % GST ( In Basic Rate must fill 12)

1

-

-

... More
Add 1 % Labour cess ( In Basic Rate must fill 1)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.