Jharkhand Urban Infrastructure Development Company Limited Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Jharkhand Urban Infrastructure Development Company Limited - JUIDCO Tender

Works
Civil And Construction
Eprocure
Opening Date20 Oct 2022
Closing Date20 Dec 2022
Tender Amount₹ 66,00,83,105 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.5 to 3.0M

20204.03

-

-

... More
3.0 to 4.5M

16155.76

-

-

... More
E/W in excavation of foundation trenches of toe wall, spillway, head regulator, intake well, outlet etc. as per designed section in hard rock where blasting is needed and disposal of excavated rock by truck beyond initial lead of 150 m but upto 1 km with all lifts including loading, unloading, and stacking properly in approved stack yard and in approved stak size as well as construction and maintainance of haul road etc. as per specification and direction of E/I.

-

-

-

... More
4.5 - 6.0 m

12864.36

-

-

... More
6.0 -7.5 m

8416.61

-

-

... More
7.5 - 9.0 m

3980.35

-

-

... More
9.0-10.5 m

3212.07

-

-

... More
10.5-12.00 m

1445.34

-

-

... More
12.00-13.5 m

712.75

-

-

... More
13.5 -15.0m

668.34

-

-

... More
15.0-16.5m

630.63

-

-

... More
PCC M 20 using batching plant, transit mixture and concrete pump

4385.25

-

-

... More
RCC grade M 25 using batching plant, transit mixture and concrete pump

10661.71

-

-

... More
RCC grade M 30 using batching plant, transit mixture and concrete pump

1414.91

-

-

... More
Providing TOR steel reinforcement of 10 mm, 12 mm & 16 mm dia bars as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire removal of rust, placing the rods in position (including carriage of bars to work site) all complete as per building specification and direction of E/I b) 12 mm

1086.89

-

-

... More
Providing and supplying in standard length high density polyethyene pipe confirming to IS 4984/14151/12786/13488, latest revision with necessary jointing material like mechanical connector i.e thread / insert joint / quick realese coupler joint / compressor fitting joint or flanged joints excluding coupler / specials and taxes. HDPE pipe of materials grade PE80-PN06 - 110 mm dia

5752.6

-

-

... More
Supplyig labours and tools for laying and jointng H.D.P.E pipes in trenches and making butt welded joint, supplying heating mirror, jack etc. and providing night guard, barrier and red light to safe guard against accident, all complete as per secification and direction of E/I. 110/100 mm dia

5752.6

-

-

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. in weep holes

54.64

-

-

... More
Inside painting Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floor and taxes all complete as per building specifciaction and direction of E/I.

992

-

-

... More
Outside Snowcem Providing two coat of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper , scaffolding, curing and taxes all complete as per building specification and direction of E/I

1001.2

-

-

... More
Ceiling whitewash Whitewasing three coats over new surface with approved quality of lime incuding cost of cleaning surface throughlly and removing the scales of smoke and mosh marks with jhama rubbing, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/I.

574.34

-

-

... More
Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and,size19x19 mm for styles and 15 x15 mm for the top and bottom rails,M.Sframes hall have a coat of metel primer of approved make and manufacture.M.Sframe shall be covered with heat mouled PVC' C' channel made from 5mm (+/0.25) thick prelaminated sheet of density 600kg/cbm , of size 30 mm thickness70mm without of which 50mm shall be flat and 20 mm shall be tapered in 45 degree angle on either side formings tiles;and 5mm thick, 95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form to pand bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail .Top,bottom and lock rail shall be provided either side of the panel. An additional 5mm (+/0.25)thick PVC strip of 20 mm width is to be stuck on the bottom side of the 'c' channel prelaminated pane ling of 5mm (+/0.25) thick PVC sheet to be fitted inside the M.S.frame welded/sealed to the styles and rails with 5mm (+/0.25) x 30 mm PVC sheet be adingo neither side and joined together with solvent cement adhesive etc,10mm thickness (5mm (+/0.25) x2nos) 20mm wide cross PVC sheet as gap insert for the rail and bottom rail .Door to be fixed to frames with 3nos M.S.powder coated but hinges of size 100 mm x 25 MM x 2 mm using 32 mm long steel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares should be fixed with 19 x 6 mm size steel screws including fixture fasting. Complete as per direction of engineer in charge.

2.52

-

-

... More
Window Supplying, fitting and fixing fully glazed steel door, windows or ventilations of standards rolled 'z' and mullian steel sections and size a per IS 1038 Joints met and welded with 100*16*3 mm MS lugs fixed in cement concrete (1:2:4) blocks 15*10*10 cm, size including cost of oxidized iron fittings with hinges, handle per steps, catch springs, 3 mm thick plain glass pens with aluminium beads and inner frame fixed with lugs with 20 mm long 6 3mm GI counter sunk machine screw and nuts and applying a coat of red lead paint carriage to ork site, hoisting and placing in position in all stories and taxes all complete as per building specification and diection of E/I

38.25

-

-

... More
Concertina Door Providing, detailing, and fabricating as per specifications, transporting to site and erecting MS Openable / Sliding / Ornamental Entrance Gates including track and wheel, locking arrangement, fixing bolts, nuts, washers, cleats, stiffeners, gussets decorative balusters, arrow heads etc. and all necessary operations like straightening, bending, cutting, drilling, grinding, machining if specified, welding etc. complete weighing 25 to 30 kg/Sqm, including cleaning, Grinding and removing the welding burr and preparing surface and applying one coat of red oxide zinc chromate primer and one coat of Synthetic Enamel paint after fabrication and second coat of Synthetic Enamel paint after erection, with approved colour, shade and brand etc. including touching up with primer etc. complete as directed by Engineer In Charge. Providing and fixing 750mm dia concertina barbed razeer type coil of 19mm wide ribbon with thickness 5 SWG and central core wire of 12 SWG with anti rust coating, supported over 5 rows of barbed wires of 14 SWG having two ply four points at 75 mm c/c, fixed to Y shape angle bracket placed at 2.5m c/c (leg of Y should be 0.51 m long and 0.23 m embeded in concrete, wing of Y should be 0.475 m long having a distance of 0.58 m between the two wing on the top) made up of 50mm x 6 mm M.S. angle embeded in cement concrete bed block of size 300mm x 300mm x 300mm. The concertina coil should be fixed to angle with M.S. Flat 25mm x 5mm thick on both the sides as runner all steel work shall be applied with one coat of red oxide zinc chromate primer and two coat of Synthetic Enamel paint etc. complete as directed by Engineer In Charge

20.25

-

-

... More
Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 450 mm sweep(900 RPM)

17

-

-

... More
Water proofing for old and new roof slab:- Provinding and laying water proofing treatment on roof slab by applying two component, factory designed ready to use acrylic modified flexible material applied with brush roller, spray for water proofing coating as per manufacturer specifications with following steps:- a) surface preparation - Providing and cleaning of concrete surtace to remove dust, oil, grease including removat of existing loose pairnt coaling, and cement laitance by cleaning with compressed alir & water yet including all materials, labour, tools complete. Ponding test to be done arter plugging all outlets and to be checked from soffit to idenüty seepage,leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt.Ltd. / MYK Schomberg /Dr FiatFosroc or equivallent. Providing and reparing of all corners an joints siuch as those between the parapet wall and the roof slab etc shall be chamfered with 150mm X 150 mm fillet of mortar (Cement: sand- 1:4) admixed with acnylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fidt or equivalent. Before chamfering a prime coat shall be given with the slumy of acrylic polymer. Repairing surface iregularities, damaged concreteln base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. b)1st Coat :- Apply 1st coat of wo component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is stll green. 1st coat should be applied1.50 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." (c) 2nd Coat -To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 ko Sqmilcoat For the purpose of measurement the entire treated surface will be measured." After three days of drying the 2nd coat, the rain water outiets to be plugged and ponding test to be done for 48 hours to identity seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. protected from damage before screed over it. Water proofing Brand ka Topseal 109hi / Fosroc Brushbond RFX/ Dr Fiit Pidiffin 2K/MYK Aquatin TG Product Perfomanco- Chemical Base Part A Acryfic oopolymer, Part 8: Specially graded cemeniDous powder Density 1.6hgl (mixeg density,.at 2t Tensle Strength N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength-2 N/mm2

574.34

-

-

... More
(concrete failure) (According to 1so 4824) Slant-Shear Bond Strength-4 Nmm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370) (d) Protection of treated surface with PCC- The treated surface should jbe covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 mt x 2mtkeeping 6 mm gap between the p of 100 ml per bag of of cement to be added in the screed concrete (paid separately for this items) All corners shall be chamfered with 150mm X 150 mm fillet. The rainwater outiets shal be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the periphes mouth to be sealed with moisture insensilive epoxy putty.

-

-

-

... More
PCC Grade M 25 using batching plant, transit mixture and concrete pump

210.21

-

-

... More
10 T EOT Capacity lifting device Electrically Operated Circular or Rectangular Travelling Crane (Single Girder) Supplying, Erecting and Commissioning Single Girder electrically Operated Circular/Rectangular over head travelling crane with 6 m Lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54 control panel and down pendant control block. 10 Tonne Capacity Above 8 m up to 10 m span

1

-

-

... More
Square Bar / Rail :- Providing, erecting and fixing square bar of EN 8 as rail for overhead crane on provided track, girder/continuous corbel beam, including supporting plate and "J" bolts. 50 x 50 mm (EN 8)

30

-

-

... More
Providing 50 mm thick cement concrete flooring (1:2:4) with 20 mm to 6mm, size graded Stone chips finished with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/|

1173.67

-

-

... More
Supply, Installation, Testing and Commissioning (SITC) of approved make Sluice Gate of 1.5 M X 1.00 M SS 316 wall mounted electric actuator operated rising type single faced suitable for 12.04 water design head having 12.50 m (CL-PL) distance FBC type including all necessary accessories and labour all complete as directed by Engineer in charge.

9

-

-

... More
Dewatering Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge etc. complete.

135000

-

-

... More
Carriage of material

-

-

-

7502.44

-

-

... More
Aggreegate

15004.87

-

-

... More
Cement

6468.09

-

-

... More
Providing, constructing Coffer Dam in river basin / dam storages as per type design including excavation, filling the middle portion with B.C. soil (in gunny bags if required). Providing impervious / semipervious materials on both sides of B.C. soil (in gunny bags if required) including ramming, compacting to the satisfaction of Engineer-in-charge till the completion of work including dismantling coffer dam after completion of works and disposing off the material as directed by the Engineer-in-charge. NOTE:- Top width payable shall be 2 Mtr. and maximum payable side slopes shall be 1.5 horizontal to 1 vertical, if the constructed top width of the side slopes are less, then the measurements at actual are payable. Extra top width or flat slopes are not payable. Contractor is free to use ballies, plastic sheets, piles, pipes, CGI sheets for supporting hearting materials instead of impervious/ semi-pervious hearting materials for which no extra payments shall be payable. 30% payment shall be withheld for dismantling of coffer dam.

120856.22

-

-

... More
Clearing Grass and Removal of Rubbish (Maximum 150mm) by manual means and disposal at a lead of 50 metres.

0.49

-

-

... More
PROPOSED RUKKA INTAKE FOREBAY (MECHANICAL)

-

-

-

... More
Supply, Installation, Testing and Commissioning (SITC) of approved make Submersible Vertical Turbine (S.V.T) pump set of given capacity and head Pump Price including LT PMU, Autocoupling with Integral Bend with Guide Pin (SS 304)) Foundation Bolt MoC :SS 202 (Each). Cap.- 2570 m3/hr,25 m

9

-

-

... More
Supplying, Erection Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points and giving test and trial for directly coupled sewage pump set on provided foundation. Head upto 20 Mtrs 7.5 HP (Up to 36000 LPH)

1

-

-

... More
Providing, supplying and erecting at site of ductile iron / spheroidal graphite (S.G) iron D/F non-rising spindle resilient seated glandless sluice valves with handwheel & without bypass arrangement. Valves in accordance with BS 5163 of PN-101 16 rated, with body and bonnet of ductile irr:n confirming to IS 1865 Gr. 50A17 or Gr.400/ 15. Wedge fully encapsulated WRAS approved EPDM rubber (approved for drinking water), Wedge nutof brass, shaft of stainless steell .402111.4704, stem seals min.3 nos. ofNBR, internal fasteners of stainless steelA2. Body & Bonnet coated inside & outside with electrostatically applied epoxy powder coated blue colour (suitable for drinking water) as per DIN 30677-2 & GSK guidelines i,vith a coating thickness of min. 250 microns. Valves should be fulI bore & tight shut-off. Flange drilling as per IS 1538 raised face & pressure testing at manufactures works shall be done as per IS 14846. including transportation. 600 mm dia - delivery line of each pump

9

-

-

... More
Supply, Installation, Testing and Commissioning of stainless steel (SS-316) Fine Bar screen (Mechanical operated) with flat bar 50 mm X 2 mm with 6 mm spacing suitable for mounting in channel of specified size with suitable inclination complete in all respect as per technical specification, reputed make and direction of the Engineer inclusive of Banner Make Upstream Type Ultrasonic Level Sensor for following PEAK FLOW and length up to 3M.

-

-

-

... More
95.1 MLD to 105 MLD

9

-

-

... More
Add extra for additional depth of channel in Mechanical Fine bar screen beyond 3m length

9

-

-

... More
Providing, erecting electric Valve actuators totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and hand wheel for emergency manual operation which will automatically disengage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction motor working on 440 Volts +/- 10%, 3 phase, 50 Hz AC of intermittent duty rating S-2, insulation class "F" and temp rise restricted to class "B" with IP - 67 protection class suitable for DOL starting and with three thermostat and 30% over load margin. The torque rating of reduction gear box shall be atleast 1.5 times max. torque required for opening and closing of valve with integral starter controls having four limit switches 1 for OPEN, 1 for CLOSE & 2 Nos for intermidiate positions for interlocking etc complete. 600 mm dia - delivery line of each pump

9

-

-

... More
Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking, in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) without bypass arrangement PN-1.6 600 mm Dia

9

-

-

... More
Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. 600 mm Dia

9

-

-

... More
Providing, erecting and commissioning M.S. Dismantling joint as per requirement and Department's approved drawing and specifications, including machining and rubber rings and suitable for 16 kg/cm2 working pressure with required flanges of suitable size with nut bolts etc complete. The joint should have through long bolts so that during normal working pressure there should be no sliding movement of sliding flanges. 600 mm dia

9

-

-

... More
Manufacturing, providing and supplying spirally welded / ERW/ SAW / fabricated M. S. pipes including procurements of plates, gas cutting to required size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming ‘V’ edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, unloading, stacking, in all respect etc. complete as per IS - 3589 and IS-5504 as applicable as per specifications.

-

-

-

... More
600 mm dia (delivery pipe from each pump) Thickness 10 mm

204.75

-

-

... More
2000 mm dia (header pipe to rising main) Thickness 16 mm

25

-

-

... More
Lowering, laying in position to correct line and level including M. S. pipes with / without any outcoating, on pedestals or chairs upon piers, trestles etc. The rate to include loading, unloading, hoisting, marginal cutting wherever required, assembling and tack welding, transportation upto 500 m. etc. complete.

-

-

-

... More
600 mm dia (delivery pipe from each pump) Thickness 6 mm

204.75

-

-

... More
2000 mm dia (header pipe to rising main) Thickness 16 mm

25

-

-

... More
Providing, supplying and erecting ISI standard CI flanged / S& S specials including all statutory duties & taxes in all respect, railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store /site, unloading stacking etc. complete. .

-

-

-

... More
600 mm

459

-

-

... More
2000 mm

5409

-

-

... More
Providing, supplying and erecting ISI standard MS specials of required thickness with 3 coats of approved make epoxy paint from inside and outside excluding all statutory duties & taxes in all respect, inspection charges, transportation to stores / site, and stacking, etc. complete. Only flanges with machining and drilling holes, etc. com-plete more than 40 mm thick

3000

-

-

... More
PROPOSED RUKKA INTAKE FOREBAY (ELECTRICAL)

-

-

-

... More
Supply & fixing of 33 KV off load type gang operated 3 Pole horizontal type switch rating 800 A, 3- phase, central post rotating double break isolator complete with MS hardwares, copper moving & fixed contacts assembly of 9 Nos. Post Insulators conforming to IS-5350 Part III and IS-2544 with GI pipe of suitable length for operation.

1

-

-

... More
SITC of Main 33KV HT Panel comprising of 1no. 1250A VCB I/C & 2nos. 1250A VCB O/G  with all necessary indications, metering and protection. All panels has to be provision for SCADA communcation

1

-

-

... More
Supply, receving, storing,inspection, handling , assembilng ,installing in correct alligned position, effecting proper connections, testing and commissioning of copper wound Transformers 33/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type of 2.5 MVA , Standard accessories with off load tap changer (+5% to -10% in steps of 2.5%), winding / Top --- temperature rise of 450/400 C first fill oil, having permissible total less values not exceeding 7.5% of the maximum total loss values for 11 KV as per energy efficiency level - 2 at basic Insulation level conferming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014.

2

-

-

... More
Supply, installation, testing & Commissioning of Main LT Panel comprising of 2 nos. I/C and 1 Bus Coupler (4000A) and main outgoing feeders are 200KW (Soft Starter) 10nos and 6nos 100A MCCB as designated in the SLD with all necessary indications, metering and protection . The panel shall be made of 2.0 mm thick CRCA steel sheet with the doors and gland plate being of a 3.0 mm thick CRCA steel. The panel shall have proper rubber gasketing and louvers for heat discipation. The panel shall be IP 54. Hinges to be provided for lifting the panel. The panel shall have base plate so that it can be floor mounted as well. Scope includes GI supports for installation of switchboard, danger board, etc.Fault level shall be 50KA/ 1Sec. Kept provision for 2nos 700KVAR APFC.

1

-

-

... More
SITC of Automatic power factor correction panel with 700 kVAR Capacitor bank comprising with APFC relay, capacitor banks,contator,indicating lamp, power factor meter, free standing made of sheet steel enclosed, aluminium bus bar, earthing pads, complete with power & control wiring and suitable to improve the power factor of the system up to 0.98 lag.

2

-

-

... More
415 V, 10KA/1sec, Al busbar, 3phase 4wire LT Aux. Panel. Wall mounted. Enclosure shall be CRCA sheet, 1.6mm for non load bearing area and 2mm for load bearing area. Panel shall be compertmentalized only. Incomer= 200A TPN MCCB 1no. Outgoing feeder= 32A TPN MCB 6nos, 16A SPN MCB 6nos. Considering all metering and protection. Paint shall be as per IS 5.

1

-

-

... More
200AH 110V VRLA Battery and F&FCB Battery Charger with integrated DCDB

1

-

-

... More
Supply , Installation, Testing and Comissioning of wall mounted Push Button station for AHU/Air washers made out from powder quoted CRCA sheet of 16 SWG , illuminated ON/OFF push button including making connections etc as required complete in all respect. All as per pre approved by Engineer in charge.

12

-

-

... More
Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 33 K.V.(E) in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc.as required of size as per points (a), (b), (c) mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity 99.6 % & as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . All above as per pre approved by Engineer in charge. 33 kV 3C-240 sqmm XLPE Cable

1000

-

-

... More
1.1 kV 3.5C-300 AL XLPE cable

3000

-

-

... More
4Cx16sqmm, AL, 415V, 1.1 kV

1000

-

-

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity 99.6 % & as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. 1.1 kV 3C-6 AL XLPE cable

500

-

-

... More
Supplying and drawing following sizes FRPVC insulated copper conductor single core cable in existing surface/recessed steel/PVC conduit including dismantling as required. 1.1 kV 3C-2.5 CU XLPE cable

2500

-

-

... More
Supplying and drawing following sizes FRPVC insulated copper conductor single core cable in existing surface/recessed steel/PVC conduit including dismantling as required. 1.1 kV 10C-2.5 CU XLPE cable

3000

-

-

... More
Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for 11 KV / 33 KV cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. 11 KV End Termination Kit Indoor type 33kV 3C-240 sqmm XLPE Cable (OUT DOOR)

2

-

-

... More
Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for 11 KV / 33 KV cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. 11 KV End Termination Kit Indoor type 33kV 3C-240 sqmm XLPE Cable (INDOOR)

5

-

-

... More
Supply & Making of Heat shrinkable type outdoor straight through joint as per PWD specification for electrical Works for following size of PVC/ XLPE insulated aluminium conductor cable of 1.1 KV grade including cost of compound, sleeves etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1.1kV 3.5C-300 sqmm AL XLPE Cable

40

-

-

... More
Supply & Making of Heat shrinkable type outdoor straight through joint as per PWD specification for electrical Works for following size of PVC/ XLPE insulated aluminium conductor cable of 1.1 KV grade including cost of compound, sleeves etc. as required. All as per pre approved by Engineer in charge. 4Cx16sqmm, AL, 415V, 1.1 kV

10

-

-

... More
Supply & Making of Heat shrinkable type outdoor straight through joint as per PWD specification for electrical Works for following size of PVC/ XLPE insulated aluminium conductor cable of 1.1 KV grade including cost of compound, sleeves etc. as required. All as per pre approved by Engineer in charge. 1.1 kV 3C-6 AL XLPE cable

20

-

-

... More
Supply & Making of Heat shrinkable type outdoor straight through joint as per PWD specification for electrical Works for following size of PVC/ XLPE insulated aluminium conductor cable of 1.1 KV grade including cost of compound, sleeves etc. as required. All as per pre approved by Engineer in charge. 1.1 kV 3Cx2.5sqmm, CU XLPE Cable

30

-

-

... More
1.1 kV 10C-2.5 CU XLPE cable

40

-

-

... More
Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and dulysuspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required. All as per pre approved by Engineer in charge. 600mm x 50mm x 2.0mm

1200

-

-

... More
Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and dulysuspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required. All as per pre approved by Engineer in charge. 300mm x 62.5mm x 2.0mm

1000

-

-

... More
Pipe Earthing as per PWD specification for electrical Works as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge.

35

-

-

... More
Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. 50mm x 6mm G.I. Strip

2000

-

-

... More
Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. 25mm x6mm G.I. Strip

2000

-

-

... More
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 10 SWG G.I. Wire

1200

-

-

... More
Lightning Protection

-

-

-

... More
P & F lightening Conductor of G.I. bar of 25mm dia& 2m long

10

-

-

... More
Providing & Fixing of G.I. tape (Hot Dipped galvanized ) 20mm x 3mm on parapet or surface of wall fixed with porcelain or bakelite insulator (SP-35) in vertical/horizontal run as required. All as per pre approved by Engineer in charge. 20mm x 3mm G.I. ( Hot Dipped ) Strip

1000

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required

12

-

-

... More
Indoor and Outdoor Illumination System

-

-

-

... More
Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy =120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor 0.95 driver Efficiency 85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.

20

-

-

... More
Providing & Fixing of IP20 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency 85% , with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System Lumen efficacy min. 100 lm/watt ,THD 10 % , p.f.≥0.95,CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL acredeated lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge.

12

-

-

... More
90 W Street Lighting Fixtures with pressure die cast Aluminium housing.

10

-

-

... More
Supply and erection of Octagonal pole of following length and dimension as per table-3 with base plate on the cement concrete foundation of M-15 /M-20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS 1367 P III ). The pole shall be made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. The pole shall have a weatherproof flush door and locking arrangements. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning. The pole shall be completed with overhangs, Junction Box, two nos. pipes for cable entry and outgoing, wires up to lighting Fixtures. 7 Mtrs.

10

-

-

... More
Miscellaneous Items

-

-

-

... More
Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. 6 KG

12

-

-

... More
Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. 33 KV, 3 mm thick with proof voltage 36 KV / 3 min. and Break Down Voltage 65 KV

9

-

-

... More
Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. 3.3 KV, 2 mm thick with proof voltage 10 KV / 3 min. and Break Down Voltage 30 KV

25

-

-

... More
33kv line from nearest WTP substation

-

-

-

... More
Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 33 K.V.(E) in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc.as required of size as per points (a), (b), (c) mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity 99.6 % & as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . All above as per pre approved by Engineer in charge. 3 core 300.0 Sq.mm

1000

-

-

... More
RAW WATER RISING MAIN

-

-

-

... More
Manufacturing, providing and supplying spirally welded / ERW/ SAW / fabricated M. S. pipes (commercial quality) including procurements of plates, gas cutting to required size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming ‘V’ edge on both ends of pipes in all respect etc. complete as per IS - 3589 and IS-5504 as applicable as per specifications. 1800 mm (ID), Thickness - 10 mm

350

-

-

... More
Lowering, laying in position to correct line and level including M. S. pipes with / without any outcoating, on pedestals or chairs upon piers, trestles etc. The rate to include loading,unloading,hoisting,marginal cutting wherever required, assembling and tack welding, transportation upto 500 m. etc. complete. Above 1750 mm. Upto 2000 mm. dia.

350

-

-

... More
Welding in all positions with required number of runs, for M.S. pipes internally and / or externally including gauging wherever necessary, fixing appurtenances and other accessories in connection with pipe laying work as per specification. Butt Joints : Plate thickness (12 mm and above)

418.25

-

-

... More
Hydraulic testing of M.S. pipeline to specified pressure including cost of all materials and labour and water for testing for the length upto 1km., using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary. Above 1800 mm. upto 2250 mm. dia. (I.D.)

0.35

-

-

... More
Providing and applying pipe coating of fibres, coal tar and solvent based rubber modified bituminous primer of density 0.92 gms/cu cm and viscosity of 1000-2000 cps @ 150 gms/sqm followed by seven layers (4mm thick) of polythene polymerised bitumen and polyester of local 7 layers) pipe coat 4 mm should conform to requirement of IS-10221 and AWWA C-203 for prefabricated tapes including covering cost on pipe coating. Rates shall include cost of material coating and wrapping over the pipes, handling charges, preparation of pipe surface, all labour, material, etc. complete. 1800 mm Dia

1978.2

-

-

... More
Providing and applying of elastomeric (450% elongation), thermoplastic, fire retardant, coating skin tensile strength 18 to 21 Kg/ cm2 , antifungal, antibacterial, anticorrosive, graft co-polymer coating on internal surface of pipe lines. 100 Micron DFT of site bonding grade with steel surface and 100 Micron DFT of top coat. 1) pipe lines (external) in unlaid condition. 1800 mm

2008.97

-

-

... More
Gas cutting (either square cut or V cut) pipes, plates, etc. of thickness. iii) Above 10 mm. Upto 14 mm.

41.82

-

-

... More
Providing, lowering, laying, alingning, fixing in position in pipe line, manually operated DI D/F sluice valves of approved make PN 1.0 class of following dia complete (including jointing and jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. Scour Valve - 400 mm

1

-

-

... More
BFV - Supplying, loading, transporting on site, unloading butterfly valves of PN 1.6 conforming to AWWA C-504 in SGI- IS 1865(Grade 500/7) material with appurtenances and flange adaptors, nuts, bolts, washers, packings etc. stacking the same as directed on site for following diameters. (Electrically operated). The flange adapter used here conforms to AWWA C-219. 1800 mm dia

2

-

-

... More
Supplying, transporting on site and fixing Tamper proof Kinetic Air valves of PN 1.6 in Gray Cast Iron IS 210 FG 260 conforming to AWWA C-512 with sluice valves (double port) with nuts, bolts, washers etc.including making holes in the main and fixing saddle pieces,etc.complete. 200 mm dia Air Valve

2

-

-

... More
Earth work in excavation (as per I.S. 3114/1965) for laying of different types and size of pipes so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of Engineer-in-charge (b) For classification of soil item -B. 1800 mm dia.

2778.3

-

-

... More
Extra for earthwork in all kinds of soil for each additional lift of 1m or part there of over the initial lift of 1.5m as per specification and direction of Engineer-in-Charge. From 1.5 m to 2.5 m 1800 mm dia

1386

-

-

... More
Extra for earthwork in all kinds of soil for each additional lift of 1m or part there of over the initial lift of 1.5m as per specification and direction of Engineer-in-Charge. From 2.5 m to 3.5 m 1800 mm dia

546

-

-

... More
Earthwork in excavation of foundation trenches as per design section in ordinary or soft rock (vide classification of soil item-C) and disposal of excavated materials so obtained (50 m away from the edge of the trenches) with initial lead of 150 m and initial lift of 1.5m as per specification and direction of E/I.

277.83

-

-

... More
Earthwork in back filling the trenches after laying different types and sizes of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer -in- charge. 1800 mm dia

1629.81

-

-

... More
Supplying tools and cutting road as well restoring the same as per specification and direction of E/I.

-

-

-

... More
(a) Pucca Road (Except black top only taken out material to be used) for cutting road as per requirement. 1800 mm dia

37.75

-

-

... More
Dismantling of structures (dismantling of existing structures like culvert, bridges, retaining walls and other structures compramising of masonary,cement concrete, wood work steel work including T&P and scafolding wherever necessary sorting the dismental material disposal of of un- serviceable materials and stacking the serviceble materials with all leads.

10

-

-

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I.

11.25

-

-

... More
Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.

37.5

-

-

... More
PCC Grade M 20 using batching plant, transit mixture and concrete pump

5.63

-

-

... More
Carriage of materials

-

-

-

... More
Bricks

1.88

-

-

7.43

-

-

4.95

-

-

... More
Cement

1.76

-

-

... More
Cutting and Removing of the existing CI/DI/MS pipe section from trenches etc complete in all respect as directed by Engineer in Charge.

50

-

-

... More
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete.

504

-

-

... More
Dewatering Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge.

10950

-

-

... More
Removal of Tress & Site Clearence Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit to required compaction. Girth from 300 mm to 600 mm

30

-

-

... More
Silt Carrier Pipe and Chamber

-

-

-

... More
Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, including inspection charges, transport to departmental stores, unloading and stacking etc. complete as per IS- 458/1988. 300 mm NP-II Class

150

-

-

... More
Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge as per IS- 783-1985. 300 mm NP-II Class

150

-

-

... More
Hydraulic testing of RCC pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. 300 mm Dia

0.15

-

-

... More
Providing structural steel work in rolled stanchions fixed with connecting plates or angle cleats as in main and cross beams, hip and jack rafters, purlins connecting to truss members and like as per detailed desings and drawings or as directed by Engineer-incharge including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paints and over it two coats of oil painting, etc. complete.

0.03

-

-

... More
Providing and constructing on sewer, B.B. masonry circular manhole concentric cone 1.2 M dia. at bottom and 0.5 M dia. at top and upto a depth of 2.00 M with 23 cm brick work in CM 1:4 proportion excluding excavation including foundation concrete 250 mm thick and haunches and channels in c.c.1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kg., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C. frame and cover of 56 cm.dia. etc. complete as directed by Engineer-in-charge.

14

-

-

... More
Rebate for every decrease in depth of 50 cm or part thereof

3

-

-

... More
Providing and constructing on sewer, B.B. masonry circular manhole concentric cone 1.5 M dia. at bottom and 0.5 M dia. at top and upto a depth of 5.00 M with 23 cm brick work up to depth of 2 M from top and 35 cm thick brick work for balance depth in CM 1:4 proportion with 20 mm thick smooth plaster on both side in cm 1:2 proportion excluding excavation including foundation concrete 250 mm thick and haunches and channels in c.c.1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighting 5.5 kg., 1:2:4 coping and providing and fixing approved make and quality S.F.R.C. frame and cover of 56 cm.dia. etc. complete as directed by Engineer-in-charge.

1

-

-

... More
Providing 150 mm dia S.W. or R.C.C.pipes in vertical drop arrangement including providing 150 mm dia S.W.and R.C.C. pipe fixed in B.B. masonry of manhole at the required level including providing 150 mm dia double tee ,150 mm dia right angled bend, encasing in B.B. masonry 1:4 proportion all around the pipe,double tee, bend upto the foundation of manhole, jointing, cutting, filleting including neat cement rendering, plugging the opening with jungle wood knob complete as directed by Engineer-in-charge. As above but for 300 mm dia. Pipes & depth 0.60 M

1

-

-

... More
Earth work in excavation (as per I.S. 3114/1965) for laying of different types and size of pipes so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of Engineer-in-charge (b) For classification of soil item -B

341.11

-

-

... More
Extra for earthwork in all kinds of soil for each additional lift of 1m or part there of over the initial lift of 1.5m as per specification and direction of Engineer-in-Charge. 300 mm dia From 1.5 m to 2.5 m

34.11

-

-

... More
Extra for earthwork in all kinds of soil for each additional lift of 1m or part there of over the initial lift of 1.5m as per specification and direction of Engineer-in-Charge. 300 mm Dia From 2.5 m to 3.5 m

34.11

-

-

... More
Earthwork in excavation of foundation trenches as per design section in ordinary or soft rock (vide classification of soil item-C) and disposal of excavated materials so obtained (50 m away from the edge of the trenches) with initial lead of 150 m and initial lift of 1.5m as per specification and direction of E/I.

34.11

-

-

... More
Earthwork in back filling the trenches after laying different types and sizes of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer -in- charge. For 300 mm dia

354.75

-

-

... More
Supplying tools and cutting road as well restoring the same as per specification and direction of E/I.

-

-

-

... More
(a) Pucca Road (Except black top only taken out material to be used) for cutting road as per requirement. For 300 mm dia

1.62

-

-

... More
Dismantling of structures (dismentaling of existing structures like culvert, bridges, retaining walls and other structures compramising of masonary,cement concrete, wood work steel work including T&P and scafolding wherever necessary sorting the dismental material disposal of of un- serviceable materials and stacking the serviceble materials with all leads. For 300 mm dia

1.11

-

-

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. For 300 mm dia

0.68

-

-

... More
Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. For 300 mm dia

9

-

-

... More
Providing and laying in situ Cement Concrete M-10 of trap/ granite / quartzite /gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. For 300 mm dia

1.35

-

-

... More
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete.

16.79

-

-

... More
Dewatering Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete.

100

-

-

... More
Encasing of Pipe at utility / lower Cover /Major Road Crossings Providing and laying in situ Cement Concrete M- 15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete.

5

-

-

... More
Carriage of materials

-

-

-

... More
Bricks

10.72

-

-

11.08

-

-

6.1

-

-

... More
Cement

16.61

-

-

... More
RCC THRUST BLOCK

-

-

-

... More
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I.

1215.67

-

-

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I.

10.4

-

-

... More
Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.

138.72

-

-

... More
RCC Grade M 20 using batching plant, transit mixture and concrete pump.

891.38

-

-

... More
Providing TOR steel reinforcement of 10 mm, 12 mm & 16 mm dia bars as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire removal of rust, placing the rods in position all complete as per building specification and direction of E/I b) 12 mm (TMT coil Fe500)

69.97

-

-

... More
Carriage of material

-

-

-

... More
Bricks

6.94

-

-

388.8

-

-

768.58

-

-

... More
Cement

768.58

-

-

... More
VALVE CHAMBER

-

-

-

... More
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I.

26.34

-

-

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming & watering in layers not exceeding 150 mm thick with all leads and lifts including cost of all materials, labour, royalty & taxes all complete as per building specification & direction of E/I.

0.93

-

-

... More
Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.

12.54

-

-

... More
Providing and laying in situ Cement Concrete M-10 of trap/ granite / quartzite /gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete.

1.89

-

-

... More
Providing designation 75 A brickwork in CM (1:6) in foundation and plinth with approved quality of clean coarse sand of FM 2 to2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to15 mm depth, curing taxes and royalty all complete as per building specification and direction of E/I.

8.64

-

-

... More
Providing 12mm thick cement plaster(1:6) with clean coarse sand of FM 1.5including screening, curing, with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direction of E/I.

29.16

-

-

... More
Providing and placing Reinforced/ prestressed cement concrete in super structure as per drawing and technical specifications RCC M 20 Grade for slab

1.52

-

-

... More
Providing TOR steel reinforcement of 10 mm, 12 mm & 16 mm dia bars as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire removal of rust, placing the rods in position (including carriage of bars to work site) all complete as per building specification and direction of E/I b) 12 mm

0.12

-

-

... More
Carriage of material

-

-

-

... More
Bricks

4.95

-

-

4.47

-

-

3.03

-

-

... More
Cement

1.44

-

-

... More
ROAD CROSSING

-

-

-

... More
Manufacturing, providing and supplying spirally welded / ERW/ SAW / fabricated M. S. pipes (commercial quality) including procurements of plates, gas cutting to required size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming ‘V’ edge on both ends of pipes in all respect etc. complete as per IS - 3589 and IS-5504 as applicable as per specifications. For 1800 mm dia MS pipe -2200 mm dia 16 mm thick MS pipe

15

-

-

... More
Pushing of M.S. pipe of following dia for road crossing and raiLway crossing by push through method in all types of strata by using hydraulic jack and drilling machine of required diameter below 3.0 m depth including lowering, laying, jointing of M.S. casting pipe including cost of labour, fuel and material, required welding machinery, tripod, chain pulley block, crane, blower,etc., transportation and dewatering etc. complete as directed by Engineer in charge. 500 mm to 1000 mm dia MS pipe

15

-

-

... More
Providing and applying primer first coat of intertol 49 W emaline 05/ 58 pipe coat or any other equivalent approved paint to the internal surface of pipeline at site, etc. complete. For 2200 mm dia MS pipe

-

-

-

... More
First Coat

207.24

-

-

... More
Second Coat

207.24

-

-

... More
FIELD INSTRUMENTATION - PUMPING STATION

-

-

-

... More
Raw water pump house(Intake Arrangement)

-

-

-

... More
Electromagnetic flowmeter with flow transmitter and Totalizer -Size-1876mm---1800 MM

1

-

-

... More
Ultrasonic level transmitter Designing, Supplying, Installing, commissioning & testing of Ultrasonic Raddar type level transmitter CE marked with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement. Output-4-20 mA Power supply - 24V DC ext. Display - 4" LED Range- 0 to …………... mtrs Accuracy - +/- 0.25% of Full Scale or better Enclosure- IP 67 Mounting - On PLC panel

1

-

-

... More
Pressure Transmitter Designing, Supplying, Installing, commissioning & testing of pressure transmitter CE markd with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement. Output 4-20 mA Power supply - 24V DC ext. Display - 4" LED Accuracy - +/- 0.1 % of full scale or better Enclosure- IP 67

9

-

-

... More
Pressure gauges - at Outlet Line Providing, erecting Pressure gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia G.I. Pipe. Pressure gauge shall be installed as directed, with tapping on rising main. Pressure gauge (150 mm dia)

9

-

-

... More
Required Instrumentation & power cable - Designing, Supplying, Installing, commissioning & testing with Terminating & Interfacing of 2 Pair x 1 sq.mm as per IS 694 copper Shielded twisted, multistranded armoured cable on wall in GI tray or on ground.

1500

-

-

... More
Cable Trays Designing, Supplying, Installing Bending, Cutting Perforated GI tray 80 x 20 mm x3 mm thk for laying of cable etc

900

-

-

... More
CONTROL & AUTOMATION - PUMPING STATION

-

-

-

... More
Integration panel - SITC of integration panel to communicate with the centralized SCADA centerproposed under ranchi water supply scheme.The integration panel shall consist of redundant RTU ,with redundant power supply modules,redundant GPRS communication modules and 16" panel color HMI.The panel shall be rated to IP-68.The RTU panel shall be enclosed with IP-68 rated enclosure to house the panel and UPS system. The panel design shall consists of the following on a minimum for security of the panel: Door switch: shall initiate a signal to the central SCADA center when the door is opened. Flashing light with siren atop the panel with grill covering: shall flash and siren when the panel is opened on site. This shall indicate unauthorized access to the panel.

1

-

-

... More
PLC Panel Designing, Supplying, Installing, commissioning & testing of PLC Panel including PLC with CPU & Power supply unit, power supply cable, Interfacing cards, interfacing cables, wireless modules with 25 % extra quantity of all accessories.

1

-

-

... More
PLC based control monitoring and communication software Design, Supply, Installing,Testing, PLC based control monitoring and communication panel as per IEC 61131 at Pure Water Sump suitable for monitoring and control of pure water Pumps. Pressure Transmitters, Level Transmitter, PH Transmitter, Turbidity Transmitter,residual chlorine analyser ,for all pumps installed.

1

-

-

... More
Surveillance system Desiging,supplying,installing,commissioning & testing of CCTV IR water proof camera suitable for upto 100ft.with IR Dome camera,control key board,DVR,Hard Disk,cables,UPT transreceivers etc.complete.

2

-

-

... More
Supply, Installation, Commissioning, Testing, Terminating & Interfacing Software Design to PLC and commissioning of SCADA software with required hard tags plus 25% extra and with unlimited soft Tags & life time licence Development version

1

-

-

... More
Developing charges as per requirements

2

-

-

... More
SCADA Server station loaded with SCADA software,latest Windows Operating system,46" LCD monitors connected Via internal LAN network to SCADA servers.Minimum 1 TB capacity hard drive.

2

-

-

... More
Supply, Installation, Testing, Terminating & Interfacing Centralised Historian Server grade Historian PC with Window 7 or latest window operating system & Historian software development cost etc. complete

2

-

-

... More
24 Port Manageable Switch

2

-

-

... More
3 Ph input & 3 Ph output 5 kVA fully microprocessor based true online double conversion UPS system with tubular batteries suitable for 1/2 hrs along with necessary battery racks & interconnections & UPS to battery bank cables to provide UPS power for control system and all instruments and integration panel

2

-

-

-

-

-

... More
Tree plantation at project sites

150

-

-

... More
Monitoring Measures

-

-

-

... More
Ambient Air Quality Monitoring- For parameters – PM-2.5 & PM-10, SO2, NO2, CO from NABL approved laboratory and submission of report complete in all respect. (Quarterly 3 Locations, pipeline network, Intake arrangement and 03 during pre-construction )

39

-

-

... More
Ambient Noise Quality Monitoring - To Identify sources of noise, Noise due to traffic/transportation of vehicles, Noise due to heavy equipment operations, Duration and variations in noise over time etc. the equivalent noise levels shall be monitored (Lday and Lnight in Leq dBA) from NABL approved laboratory and submission of report complete in all respect. (Quarterly 3 Locations, pipeline network, Intake arrangement and 03 during pre-construction )

39

-

-

... More
Surface water monitoring PH, TDS Taste & Odour, Turbidity, Magnesium, Total hardness, Total alkalinity, chloride, sulphate, nitrate, fluoride, calcium, Iron, pesticide, manganese, copper, Arsenic, Cadmium, Cyanides, Lead, Selenium, mercury. (Quarterly 3 Locations, 03 sample during pre-construction)

40

-

-

... More
Surface water monitoring for total coliform, faecal coliform, IS10500 and as per CPCB criteria (Quarterly 3 Locations, 03 sample during pre-construction)

40

-

-

... More
Operation and Maintenance

-

-

-

... More
Surface water monitoring PH, TDS Taste & Odour, Turbidity, Magnesium, Total hardness, Total alkalinity, chloride, sulphate, nitrate, fluoride, calcium, Iron, pesticide, manganese, copper, Arsenic, Cadmium, Cyanides, Lead, Selenium, Mercury. (Quarterly 3 Locations)

36

-

-

... More
Surface water monitoring for total coliform, faecal coliform, IS10500 and as per CPCB criteria (Quarterly 3 Locations, 03 sample during pre-construction)

36

-

-

... More
Capacity Building

-

-

-

... More
Training on EMP implementation (50 persons for 1 days)

4

-

-

... More
Contractors Orientation to Workers on EMP implementation (50 persons for 3 days)

4

-

-

... More
OPERATION & MAINTAINANCE FOR SCADA (The Bid will be rejected if the bidder has not quoted O & M in following rows. Price bid will be evaluated baded on methodology given in the clause 1.7 of section 3 of bid document)

-

-

-

... More
Comprehensive Operation & Maintenance With manpower to operate the pumping stations (24 x 7)- 2 operators in 8 hour shift per day (Note: The first year operation and maintenance period shall run parallel with the Defect Notification Period of 12 months after the taking over certificate is given when all works contract has been successfully completed and commissioned)

2190

-

-

... More
Comprehensive Operation & Maintenance With manpower to operate the pumping stations (24 x 7)- 2 operators in 12 hour shift per day +data transmission cost + maintenance of field instrumentation +Control & automation at all locations

2190

-

-

... More
Comprehensive Operation & Maintenance With manpower to operate the pumping stations (24 x 7)- 2 operators in 12 hour shift per day +data transmission cost + maintenance of field instrumentation +Control & automation at all locations

2190

-

-

... More
Comprehensive Operation & Maintenance With manpower to operate the pumping stations (24 x 7)- 2 operators in 12 hour shift per day +data transmission cost + maintenance of field instrumentation +Control & automation at all locations

2190

-

-

... More
Comprehensive Operation & Maintenance With manpower to operate the pumping stations (24 x 7)- 2 operators in 12 hour shift per day +data transmission cost + maintenance of field instrumentation +Control & automation at all locations

2190

-

-

... More
Max guaranteed electricty consumption ( please quote in KWH/year for the following rows in column ''M'' This cost will be used for eveluation )

-

-

-

... More
Carrying out operation & maintenance of works for a period of 5 years including cost of all supervisory staff, materials, equipments, consumables, establishment, maintenance & repairs etc. complete as directed by Engineer-in-Charge & as per detailed specifications.

-

-

-

... More
1st Year

6.5

-

-

... More
2nd Year

6.5

-

-

... More
3rd Year

6.5

-

-

... More
4th Year

6.5

-

-

... More
5th Year

6.5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.