Energy Department Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 1,01,000Document Cost
₹ 10,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ENRGY_85849_2Bid Award Id
ViewTender No
Energy/EWD/Ranchi/104/2023-24Tender Authority
Energy Department ViewPurchaser Address
-Website
http://jharkhandtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
c) 2 x 6.0+ 1 x 6.0 sq. mm earth wire (submain for 6-way DB .)
600
210600
351
d) 2 x 4.0+ 1 x 4.0 sq. mm earth wire ( for 1.5 Tr AC wiring .)
4050
1061100
262
S/F following way three pole neutral , sheet MCB distribution board, 415 volts on surface/recess,complete with tinned copper busbar , neutral busbar , earth bar , din bar , detachable gland plate , interconnections , phosphatized and powder painted including earthing etc. as reqd. ( But without MCB/RCCB/Isolator)
-
-
-
a) 4 way (4+12) double door,Vertical type
22
76252
3466
S/F following way single pole neutral , sheet MCB distribution board, 240 volts on surface/recess,complete with tinned copper busbar , neutral busbar , earth bar , din bar , detachable gland plate , interconnections , phosphatized and powder painted including earthing etc. as reqd. ( But without MCB/RCCB/Isolator)
-
-
-
a) 2 way single door
12
3804
317
a) 4 way single door
22
13398
609
b) 6 way double door
12
13572
1131
S/F following rating four pole MCCB DB complete with connection, testing etc as reqd
-
-
-
a) 63 amp/100A 16KA MCCB
22
78254
3557
S/F following rating double pole 240V isolator in existing MCB DB complete with connection, testing etc as reqd
-
-
-
b) 63 amp
12
4476
373
S/F 6 Amp to 32 Amp rating 240 volts "B" series MCB suitable for lighting and other loads of the following poles in the existing MCB DB complete with connection testing commissioning etc. as reqd.
170
30940
182
S/F PVC/G.I. Box of following sizes on surface or in recess with suitable size sheet cover, etc as reqd.
-
-
-
a)4''×4''
60
6360
106
b)4''×7''
34
4216
124
c)8''×10''
182
40586
223
S/L L.T power XLPE insulated PVC sheated (heavy duty) aluminium conductor armoured electric cable for working voltage 1100 volts IS:1554(Part I).
-
-
-
a) 3.5 core 300 sq. mm
75
180615
2408.2
b) 3.5 core 150 sq. mm
50
63107
1262.15
b) 3.5 core 120 sq. mm
295
318756
1080.53
c) 3.5 core 70 sq. mm
230
159953
695.45
50 sq. mm, aluminium lugs
6
34
5.8
70 sq. mm, aluminium lugs
54
546
10.12
120 sq. mm, aluminium lugs
18
284
15.81
150 sq. mm, aluminium lugs
8
174
21.84
300 sq. mm, aluminium lugs
6
317
52.88
laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size exceeding 185 sq. mm but not exceeding 400 sq mm direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as reqd.
50
12300
246
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Above 35 sq. mm to 95 sq mm (clamped with 20mmx3mm GI Tape)
200
14000
70
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 120 sq. mm (clamped with 20mmx3mm GI Tape)
220
18040
82
Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
3
31998
10666
Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including solding etc. as required.
30
4200
140
Fabrication and installation of cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade making PCC plinth and foundation including fitting / fixing /connection & transportation up to work site , labour charge etc all complete.(for main panel)
1
291802
291802.59
800 amps, MCCB 35 KA fixed thermal setting = 1 nos.
-
-
-
315 amps, MCCB 35 KA fixed thermal setting = 3 nos.
-
-
-
250 amps, MCCB 35 KA, fixed thermal setting = 3 nos.
-
-
-
Digital Volt Mtr. (0-500Volt)- 3 phase class 0.5 = 1 Nos.
-
-
-
Digital AMP Mtr. (0-500AMP)- 3 phase class 0.5 = 1 Nos.
-
-
-
LED Indecator lam R/Y/B/G = 3 Nos.
-
-
-
C.T. Coil of C.T. Ratio 300/5 = 3 Nos.
-
-
-
25mm x 5mm copper strips (1.15 kg/mtr) = 20 kg
-
-
-
50mm x 5mm copper strips (2.30 kg/mtr) - 29 kg
-
-
-
Fabrication and installation of cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade making PCC plinth and foundation including fitting / fixing /connection & transportation up to work site , labour charge etc all complete.(for sub panel)
3
453029
151009.89
315 amps, MCCB 35 KA fixed thermal setting = 1 nos.
-
-
-
200 amps, MCCB 35 KA, fixed thermal setting = 4 nos.
-
-
-
Digital Volt Mtr. (0-500Volt)- 3 phase class 0.5 = 1 Nos.
-
-
-
Digital AMP Mtr. (0-500AMP)- 3 phase class 0.5 = 1 Nos.
-
-
-
LED Indecator lam R/Y/B/G = 3 Nos.
-
-
-
C.T. Coil of C.T. Ratio 300/5 = 3 Nos.
-
-
-
25mm x 5mm copper strips (1.15 kg/mtr) = 29 kg
-
-
-
Fabrication and installation of cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade making PCC plinth and foundation including fitting / fixing /connection & transportation up to work site, labour charge etc all complete .
9
258371
28707.9
200 amps, MCCB 35 KA fixed thermal setting = 1 Nos.
-
-
-
LED Indecator lam R/Y/B/G = 3 Nos.
-
-
-
25 mm x5 mm x copper Strip (1.15 kg/ mtr) = 6 kg
-
-
-
16 SQ mm. PVC insulated ISI marked single core copper cunductor cable. = 4 mtr.
-
-
-
16 sq.mm. copper lugs = 8 Nos.
-
-
-
GST @ 18%
1
759043
759043.72
Labour Cess @ 1%
1
49759
49759.53
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements