Drinking Water And Sanitation Department Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 82,600Document Cost
₹ 5,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DWSD_92713_2Bid Award Id
ViewTender No
DWSD Dhanbad 16-2024-25Tender Authority
Drinking Water And Sanitation Department ViewPurchaser Address
-Website
http://https://jalshakti-ddws.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing floor/wall mounted type cubical L.T motor control panel fabricated with18 SWG MS sheet and painted, dust & vermin proof, proper ventilated consisting of :-
a. Proper distribution 100 amp copper bus bar 4 pole- 1 set
b. Microprocessor based TPN MCCB 100 amp L&T/Siemens/ABB make with earth fault relay for incoming feeder – 1 Nos
c. MCCB 100 amp TP L&T/Siemens/ABB make for outgoing feeder-2 nos
d. 32A DP MCB for lighting – 1 Nos.
e. 0-500 v voltmeter with selector switch – 1 set (f) CT operated ampere meter 0-100 with CT – 3 Set, phase indication neon lamp- 6 Nos.
(g) FASD of suitable size-2nos. (h) S.P.P – 2 Nos. doing internal wiring with proper gauge of copper wire etc all complete Job and testing on load – 1 Set
1
-
-
Cost towards supplying and laying of 10 mm2 x 3 core PVC insulated and PVC sheathed, 1.1 KV grade unarmoured copper cable of reputed make and ISI marked doing connection from panel to both motor
30
-
-
Cost towards supplying and laying of 70 sq. mm x 3.5 core pvc, insulated and pvcshethed, 1.1 KV grade armoured alluminium cable of reputed make and ISI marked for doing connection from pole to main switch to panel
25
-
-
Cost towards making cable mouth for
a. 10 mm2 – 24 Nos.
24
-
-
b. 70 mm2 – 16 Nos.
16
-
-
Supply & fixing 3 Ton capacity triple gear chain pulley block with 6 mtr lifting chain of reputed make & I.S.I. marked
1
-
-
Cost for making new common header with supply and fitting of 6” dia heavy duty G.I. pipe 6 mtr, 6”dia bend-2 Nos., 6”dia tee- 1 No, 6” dia flange-12 Nos., rubber insertion – 10 kg nut bolt washer – 10 kg with cutting of pipe in required length and doing welding as required length all complete job with materials and labours charges.
1
-
-
Cost for supply and fitting 100 Amp TPN main switch/switch disconnector and doing all line connection
1
-
-
Supplying 50 KVA Servo controlled voltage stabilizer suitable for input voltage 150-450 volts, output voltage of 415 volt±1%,3 Ph, 50 Hz, with copper wound transformer (oil cooled), Unbalanced type, Oil cooled, Three Phase, Frequency : 50 Hz. Speed of Correction : 35V/ second. Regulation : + 1% from no load to full load.Ambient Temperature : 0 to 55 degree centigrade (Designed for indoor/ outdoor continuous operation. Operation : Automatic cum Manual, MCB for short Circuit & Over Load Protection, High Volt -Low Volt Indicator & Volt Meter with all necessary Switches and Indicator the stabilizer shall function satisfactory even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box with bidirectional wheels for easy handling, necessary monitors and user’s controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and output voltage, Auto/Manual selector switch, Raise/Low push button etc. suitable capacity termination strips and bus bars for incoming and outgoing cable should be provided. All three phases shall independently monitored and corrected.
1
-
-
Cost for Supplying and fitting of 40Watt LED Light with its bracket and doing wiring connection etc all complete
2
-
-
WTP Clear Water Pumping Plant
Supplying all labour tools and tackles for taking out old and damaged C/F pump set with all accessories, demolition of foundation for installation of new HSC C/F pump set
2
-
-
SITC of Electrical driven Horizental split casing C/F pump set [Make: Kirloskar/WPIL/Jyoti/ Mather & Plate] having discharge capacity of clear water 72 m3/h against a total head of 36 mtr coupled with TEFC squirrel cage induction motor[Make: Crompton Kirloskar/ABB/Jyoti] operated on 415V, 3 phase, 50hz, 1460rpm mounted on common MS fabricated base plate with suitable size of CIDF sluice valve-1no, CIDF NR valve-1no, Foot valve-1no, pressure gauge-1no, tyre coupling-1set etc all complete
2
-
-
Supplying all labour tools and tackles and making PCC foundation of 4’ x 3’ x 3’ with all materials such as cement, send, stone chips, foundation bolt-6nos etc all complete and plastering and punning over exposed surface.
2
-
-
Providing floor/wall mounted cubical L.T power control panel fabricated with MS sheet and painted dust & vermin proof, proper ventilated consisting of :-
a. Proper distribution 63 amp copper bus bar 4 pole- 1 set
b. Microprocessor based TPN MCCB/ 63 amp L&T/Siemens/ABB make with earth fault relay for incoming feeder – 1 Nos
c. MCCB 63 amp TP L&T/Siemens/ABB make for outgoing feeder-2 nos
d. 32A DP MCB for lighting – 1 Nos.
e. 0-500 v voltmeter with selector switch – 1 set (f) CT operated ampere meter 0-100 with CT – Set (g)phase indication neon lamp- 6 Nos.
h.FASD Starter of suitable size-2 nos. (i) S.P.P – 2 Nos. doing internal wiring with proper gauge of copper wire etc all complete Job and testing on load – 1 Set
1
-
-
Cost towards supplying and laying of 6 mm2 x 3 core PVC insulated and PVC sheathed, 1.1 KV grade unarmoured copper cable of reputed make and ISI marked doing connection from panel to both motor
30
-
-
Cost towards supplying and laying of 50 mm sq. x 3.5 core PVC insulated and PVC sheathed, 1.1 KV grade armoured aluminium cable of reputed make and ISI marked for doing connection from pole to main switch to panel
25
-
-
Cost towards making cable mouth for
a. 6 mm2 – 24 Nos.
24
-
-
b. 50 mm2 – 16 Nos.
16
-
-
Cost for making new delivery line with common header with supply and fitting of 6” dia heavy duty G.I. pipe 6 mtr 6”dia bend-1 No. 6”dia tee- 1 No, 6” dia flange-4 Nos., 4"dia MS pipe-6mtr, 4"dia bend-2nos, 4" dia flanged-12mtr rubber insertion – 10 kg nut bolt washer – 10 kg with cutting of pipe in required length and doing welding as required length and doing welding as required length and doing welding as required all complete job with materials and labours charges
1
-
-
Cost for supply and laying of suction pipe line with supply, fitting of 6" dia MS pipe-6mtr, 6" bend-2nos, 6" flanged-5nos, rubber insertion – 6 kg, nut bolt washer – 10 kg , cutting of pipe in required length and doing welding as required length and doing welding as required length and doing welding as required all complete job with materials and labours charges
2
-
-
Making chemical earthing with required materials and labour tool & tackles
2
-
-
Suuply& laying of 8 SWG copper/G.I. wire for making earthing connection into from earthing station to panel to motor
2
-
-
Cost for supply and fitting 63Amp TPN main switch/switch disconnector and doing all line connection
1
-
-
SITC of 40KVA Servo Control Automatic Voltage Stabilizer Suitable for input voltage 220v to 450v and Out-put Voltage 415V ± 1% 3phase 50hz with copper wound transformer (Oil cooled) as mentioned below. The stabilizer self function satfictorily even if in coming supply is unbalanced between phases within range of 10% . The stabilizer should be constructed in cubical box, with bidirectional wheels for easy handle, necessary monitors in user’s control on front panel such as indication, alarm, volt meter and selector switch for measuring input and output voltage, auto/manual selector switch, raise /low push button etc. Suitable capacity termination strips and bus-bars for incoming and outgoing cable should be provided. All 3 phases shall be independently monitored and corrected .
Following protections and indication shall be incorporated as per ISI 9815
a) Over voltage/under voltage
b) Single phasing c) Cut off contactor with electronig output sensing unit d) Suitable change over switch and earthing (Include 200 ltr T.Oil)
1
-
-
Cost for transporting of taken out pump set and other materials from pump plant to store Dhanbad