Drinking Water And Sanitation Department Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Drinking Water And Sanitation Department - DWSD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Jun 2023
Closing Date16 Jun 2023
Tender AmountRefer Documents 
Notes
Download

Summary

E-quotation For Sitc Of V.t Pump Set, Transformer, 3.3kv Ht Panel,

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying installation testing and commissioning of forced water lubricated vertical turbine pump with SS 410 Shaft and impeller make WPIL/Kirloskar/mather and platt/Jyoti having discharge 415m3/hr of raw water against a total head of 13.22 meter with 20 ft. S.S line shaft C.I spider bearing with rubber cutless bush driven by suitable squirrel cage solid shaft vertical turbine induction motor make jyoti/C&G/Kirloskar/ABB 3 ph. 50 Hz 3300V + 10%, 1450-1500 RPM with suitable soft starter make Schneider (suitable for 60 HP) to operate on 3300 V, 50 Hz, 3 ph AC supply of reputed make confirming to ISI and BIS mark soft starter shall be provided with suitable thyristors, ammeter with selector switch and CT’s motor protection relays for protection against under/over voltage, phase reversal, over current relay etc suitable for 60 H.P V.T pump set. reflex Valve, sluice valve and pressure Gauge etc all complete.

1

-

-

... More
Supplying, Installation testing and commissioning of polder type submersible pump set having discharging capacity of clear water 235 m3/hr against a total head of 34 meter make WPIL/kirloskar/wilo working on 3 ph, 50 Hz, 2900 RPM with SS impeller ,shaft strainer etc with suitable size C.I.D.F sluice valve and N.R valve, Pressure Gauge etc all complete job continuous working upto 10-12 Hour.

1

-

-

... More
Supplying, Installation testing and commissioning of polder type submersible pump set having discharging capacity of clear water 115.2 m3/hr against a total head of 34 meter make WPIL/kirloskar/wilo working on 3 ph, 50 Hz, 2900 RPM with SS impeller ,shaft strainer etc with suitable size C.I.D.F sluice valve and N.R valve, Pressure Gauge etc all complete job continuous working upto 10-12 Hour.

1

-

-

... More
Supplying, Installation testing and commissioning of polder type submersible pump set having discharging capacity of clear water 165 m3/hr against a total head of 34 meter make WPIL/kirloskar/wilo working on 3 ph, 50 Hz, 2900 RPM with SS impeller ,shaft strainer etc with suitable size C.I.D.F sluice valve and N.R valve, Pressure Gauge etc all complete job continuous working upto 10-12 Hour.

1

-

-

... More
Supplying Installation Testing and commissioning of 20 Stages Submersible Cooling pump set having discharge Capacity 3.4 LPS against a total head of 160 meter suitable for working on 415+ 10%, 3Ph, 50HZ, 2900 RPM AC supply with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust, Water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufactures design with 3 meter submersible copper conductor Cable in single/double run shall be provided with each pump.

1

-

-

... More
Providing floor mounted cubical L.T power control panel fabricated with MS sheet and painted dust and vermin proof consisting of – a) Proper distribution 400 amp copper bus bar 4 Pole-1 set b) TPN MCCB 250 Amp L&T/ siemens make for incoming feeder – 1No. c) MCCB 200 AMP TP L&T /siemens make for outgoing feeder-3 Nos(2W+1S),32ADP MCB for lighting -2 nos. d) 0-500 V voltmeter with selector switch-1 set CT operated ampere meter (0-300A) with CT- 2 sets, phase indicating neon lamp- 3 sets doing internal wiring with proper gauge of copper wire etc all complete.

1

-

-

... More
Supplying and fitting Jyoti make 3.3KV HT Vacuum Contactor panel consisting of – i. Sheet steel cubicle floor mounting suitable for indoor installation having busbar rated 3.3 kV, 400 A, 40 kA/1 sec ii. Draw out type Vacuum Contactor rated 3.3 KV, 400 A, 3.2 KA for 1 sec with closing coil & shunt trip coil suitable for 110 V DC and spring charging motor suitable for 230V AC through bridge rectifier iii. LED Indicating lamps iv. Trip-Neutral-close switch, spring return to neutral switch v. Local remote switch vi. Analog Ammeter with selector Switch vii. Digital Multifunction meter viii. Numerical Communicable type 3O/C & E/F Motor Protection relay ix. Electromechanical Master trip relay x. Trip Circuit Supervision Relay xii. Annunciate Hooter (8 Window) xii. Single phase Cast resin CTs having following parameters. CT Ratio Acc.Cl Burden(VA) 100/1/1 A 1.0/5P10 10/10 xiii. Space heater of 240V AC supply xiv. Surge Arrestor xv. MCB ( For AC & DC Supply) xvi. Illumination Lamp (IL) xvii. 3 Pin Socket with Switch xviii. Suitable cable termination arrangement for terminating bottom entry XLPE cables.

1

-

-

... More
Cost towards Overhauling, Servicing of 3.3KV HT Vacuum contactor Panel -7 Nos.(motor feeder panel-5 Nos, incomer panel-2 Nos) Switch Board at Raw water Mango which covers thorough servicing of the panels, functional checking, wiring checking, fitment of spares etc. Following spares considered for overhauling work: a. TNC Switch b. Test Service Limit Switch c. Indicating Lamp d. Closing Coll (110 VDC) e. Tripping Coil (110 VDC) f. Vacuum Interrupter

1

-

-

... More
Cost towards supplying 300mm² HT Aluminium three core 11kV cable XLPE insulated , insulation screened with extruded semi conducting compound in combination with copper tape (0.3kA for 1 sec) cores laid up inner sheath of PVC tape galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS 7098/11/85 with latest amendments. (JSOR-2018- CB 10-9)

1

-

-

... More
(i) Stand-by cable From 11/3.3 kV Sub-station to MCP (Motor control panel)

1

-

-

... More
Cost towards S/F 300mm² outdoor type HT cable termination kit (mouth XLPE Heat shrinking type ) Recom /any reputed make ISI marked for stand-by cable (JSOR 2018-TK-1-8)

1

-

-

... More
Cost towards S/F 300mm² indoor type HT cable termination kit (mouth XLPE Heat shrinking type ) Recom /any reputed make ISI marked for stand-by cable (JSOR 2018-TK-1-4)

1

-

-

... More
Laying of one number PVC insulated and PVC sheathed /XLPE Power cable of grade exceeding 1.1 kV but not exceeding 11kV of size exceeding 120 mm² but not exceeding 400mm² direct in ground including excavation, sand cushioning ,protective covering and refilling the trench etc. as required. for Standby cable. energy depth 6.2

1

-

-

... More
Supplying and laying 3 core 120sq. mm 3.3 kv HT aluminum three core cable XLPE insulated insulation screened with extruded semi conduction screened with extruded semi conducting compound in combination of copper tape(0.3KA for 1sec) cores laid up inner sheat of PVC tape galvanized flat strip armoured and overall PVC sheathed cable confirming to IS:7098/11/85 with latest amendments.

1

-

-

... More
Supplying and laying 3 core 95sq. mm 3.3 kv HT aluminum three core cable XLPE insulated insulation screened with extruded semi conduction screened with extruded semi conducting compound in combination of copper tape(0.3KA for 1sec) cores laid up inner sheat of PVC tape galvanized flat strip armoured and overall PVC sheathed cable confirming to IS:7098/11/85 with latest amendments.

1

-

-

... More
Supplying and laying 3 core 70sq. mm 3.3 kv HT aluminum three core cable XLPE insulated insulation screened with extruded semi conduction screened with extruded semi conducting compound in combination of copper tape(0.3KA for 1sec) cores laid up inner sheat of PVC tape galvanized flat strip armoured and overall PVC sheathed cable confirming to IS:7098/11/85 with latest amendments.

1

-

-

... More
Supplying and laying 16 Sq. mm 3 core XLPE/PVC insulated and PVC sheathed copper conductor flat submersible cable of reputed make and ISI Mark for 3 nos of pump sets in a bunch of 2 nos. from panel board to submersible p/set.

1

-

-

... More
Supplying and laying 6 Sq. mm 3 core XLPE/PVC insulated and PVC sheathed copper conductor flat submersible cable of reputed make and ISI Mark for 3 nos of pump sets in a bunch of 2 nos. from panel board to submersible p/set.

1

-

-

... More
Supplying and laying 10 Sq. mm 3 core XLPE/PVC insulated and PVC sheathed copper conductor flat submersible cable of reputed make and ISI Mark for 3 nos of pump sets in a bunch of 2 nos. from panel board to submersible p/set.

1

-

-

... More
Providing and erecting Indoor type termination kit for 3.3 KV XLPE screened 120 sq mm 3 core cable.

1

-

-

... More
Providing and erecting Indoor type termination kit for 3.3 KV XLPE screened 95 sq mm 3 core cable.

1

-

-

... More
Providing and erecting Indoor type termination kit for 3.3 KV XLPE screened 70 sq mm 3 core cable.

1

-

-

... More
Supplying & installation single girder hand operated circular/rectangular traveling crane with 6 m lift complete with 5 ton chain pulley block ISI marked and traveling trolley both tested for 50% overload including arrangement for longitudinal travel/ circular travel and cross travel with wheel hand chain, etc complete as per IS: 3832.

1

-

-

... More
Cost of Supplying and Installation 2V, 64Ah battery for operating 6 Nos. 3.3 KV MCP (Motor Control panel) board make exide/Argon/ISI Mark by replacing damaged battery with deducting the cost of taken out scrap battery. (55 Nos.)

1

-

-

... More
Cost towards supplying and Installation battery charger 110V, 15 Amp heavy duty with indicating meter ISI Marked by replacing damaged battery charger and deducting the cost of taken out scrap battery charger.

1

-

-

... More
Supply and Construction of D.P Structure by supplying erecting installation and commissioning of PCC pole top bracket, channels, back clamps, 11 KV disc insulator with hardware , MS angles, top channel, DO fuse 400 Amp 3 Pole horizontal type AB switch-100, Horn gap fuse with base channel-3 sets 11 KV lightening arrestor-1 set of 3 Nos, G.I wire stay set complete nut bolts, providing earthing of transformer- 2 nos (one no for neutral and one no for body) with all required materials and labours, PCC foundation work for transformer, fabrication work required for the job as per site condition and taping of H.T Line from existing D.P structure.

1

-

-

... More
Supplying, installation, testing & commissioning of outdoor type 250 KVA 11/0.433 KVA copper wound distribution transformer with of load tap changer 12.5 % to 2.5% in step of 2.5% continuously rated for three phase,50 Hz, full load and temperature rise out exceeding 45 degree centigrade by thermometer in oil and 50 degree centigrade by the resistance in winding after continuous, run at full load rating, the transformer should have oil immersed winding having vector group of 0.4/11, HT side connected in delta & LT side connected star with neutral brought out connected. The transformer should have power terminal bushing arrangement on HT side & cable box in LT side with standard fitting for mounting of transformer with first filling of transformer oil including all accessories etc. all complete with all materials make –kirloskar/synergy/crompton Greaves(TR1-5)

1

-

-

... More
Supplying, installation, testing & commissioning of outdoor type 100 KVA 11/0.433 KVA copper wound distribution transformer with of load tap changer 12.5 % to 2.5% in step of 2.5% continuously rated for three phase,50 Hz, full load and temperature rise out exceeding 45 degree centigrade by thermometer in oil and 50 degree centigrade by the resistance in winding after continuous, run at full laod rating, the transformer should have oil immersed winding having vector group of 0.4/11, HT side connected in delta & LT side connected star with neutral brought out connected. The transformer should have power terminal bushing arrangement on HT side & cable box in LT side with standard fitting for mounting of transformer with first filling of transformer oil including all accessories etc. all complete with all materials make –kirloskar/synergy/crompton Greaves (TR1-5)

1

-

-

... More
Cost towards supplying and laying 150 mm2x 3.5 core PVC insulated and PVC sheathed armored aluminum cable 1.1 KV grade and doing connection from transformer to panel board

1

-

-

... More
Cost towards supplying and laying 120 mm2x 3.5 core PVC insulated and PVC sheathed armored aluminum cable 1.1 KV grade and doing connection from transformer to panel board

1

-

-

... More
Cost towards supplying and laying 70 mm2x 3.5 core PVC insulated and PVC sheathed armored aluminum cable 1.1 KV grade and doing connection from transformer to panel board

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.