Drinking Water And Sanitation Department Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 13,900Document Cost
₹ 1,250Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DWSD_93852_8Tender No
DWSD/SAHIBGANJ- 01/2024-25, 9TH CALLTender Authority
Drinking Water And Sanitation Department ViewPurchaser Address
-Website
http://https://jalshakti-ddws.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(b) Above 50.00 m depth. In Rural Areas
270
238788
884.4
Supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe etc. all complete job. (DWSD Item 120)
30
52800
1760
Supplying all materials, labour, tools & equipments for fitting & fixing 200mm dia MS cap over casing pipe complete job. (DWSD Item 120 B)
1
242
242
Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump
-
-
-
Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.
-
-
-
SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.
-
-
-
i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)
-
-
-
ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.
-
-
-
iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.
-
-
-
iv) The module mounting structure should be hot dip galvanized according to IS 4759.
-
-
-
v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided
-
-
-
vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)
-
-
-
vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV
-
-
-
viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.
-
-
-
ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.
-
-
-
x) The motor pump set should have a 5 years warranty.
-
-
-
xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)
-
-
-
xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.
-
-
-
xiii) The system should be as per MNRE guide line & Eco-friendly with suitable arrangement to operate new pump manually.
-
-
-
xiv) With third party inspection before dispatch.
-
-
-
xv) Fitting, fixing & mounting on water tank steel structure.
-
-
-
xvi) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.
-
-
-
The following details should be marked indelibly on the motor pump set
-
-
-
a) Name of the Manufacturer or Distinctive Logo.
-
-
-
b) Model Number.
-
-
-
c) Serial Number.
-
-
-
Solar submersible motor pump (SPV DC Type)
-
-
-
i) 2 HP (DC Pump) with 1800 WP minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 120 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)
1
170820
170820
Provision of Solar Night Lamp.
1
1000
1000
Galvanised Chain-line mess Fencing around Solar Panel where bore well is away from tower
-
-
-
Making 30 cm (12") dia bore up to 4M below ground with hand auger of approved quality in ordinary soil (vide classification of soil item-A) true to plum and without eccentricity in any stage of operation and disposal of the exacavated earth up to 50m lead including all lifts all complete as per approved design and direction of E/I.
12
1868
155.73
Providing PCC M-150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5 to 3 including screening shuttering, mixing cement concrete in mixer and placing in position, vibrating, curing, taxes and royalty all complete as per building specification direction of E/I.
0.85
3874
4569.12
Labour cost of fitting and fixing Galvanised chain-link mess up height of 2 M including cost of staples (but excluding the cost of cement concete angle iron posts, its cutting and making holes, nuts and bolts) all complete as per specification and direction of E/I.
16
880
55
Drilling 6mm dia holes in M.S Angle iron for fixing of stables etc. as per building specification and direction of E/I.
48
433
9.03
Labour cost cutting of M.S Angle iron posts to required length, one end splitted as fish tailed in a length of 150mm complete as per building sepcification and direction of E/I.
8
225
28.21
Supplying, fitting and fixing straining bolts with nut size 22cm*10mm dia tighten the barbed wire with corner post complete as per building specification and direction of E/I.
48
404
8.42
Supplying, fitting and fixing Galvanised chain -link mess having 3mm thick wire cell type 40 x 40 mm fitted on M.S. angle frame with two diagonals having 25x25x5mm size angle including cost of fabrication, providing necessary bocking arrangement with haskal and domny duly fixed in angle post, applying a priming red lead paint over steel work, taxes excluding the cost of Galvanised chain-link mess all complete.
23.5
2797
119.03
Cost of Galvanised chain-link mess having 3 mm thick wire cell type 40x40 mm not less than 3.1 kg/Sqm
50
3722
74.45
Cost of 50 x50 x6 mm M.S angle
100
5060
50.6
Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
-
-
-
Cement Lead 10 Km (Avg.)
0.28
140
502.6
Sand Lead 15 Km (Avg.)
0.38
130
342.9
Stone Chips Lead 20 Km (Avg.)
0.76
317
417.3
Annual Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 5 years
-
-
-
O & M Cost for 1st year
1
9000
9000
O & M Cost for 2nd year
1
10264
10264.97
O & M cost for 3rd Year
1
10880
10880.87
O & M cost for 4th Year
1
11533
11533.73
O & M cost for 5th Year
1
12225
12225.75
Provision of One No. SIM card & its recharging cost for RMC
5
4000
800
Add 18 % GST
1
105076
105076.77
Add 1% Labour Cess
1
6888
6888.37
Evaluation Notes How It Works ?