Drinking Water And Sanitation Department Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Drinking Water And Sanitation Department - DWSD Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date12 Jun 2024
Closing Date19 Jun 2024
Tender Amount₹ 85,77,942 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying labour and equipment for digging well vide classfication of soil item-C including removing the spoils to a safe distance upto 50m from the edge of the well all complete as per specification and direction of E/I.

-

-

-

... More
(a) E/W 03 to 04 metre depth below G.L

28.3

17780

628.38

... More
(b) E/W 04 to 05 metre depth below G.L item no. 3.1.67

24.65

17120

694.58

... More
(c) E/W 05 to 06 metre depth below G.L

21.25

16169

760.78

... More
(d) E/W 06 to 07 metre depth below G.L

18.11

14976

826.98

... More
(e) E/W 07 to 08 metre depth below G.L

15.22

13591

893.18

... More
(f) E/W 08 to 09 metre depth below G.L

12.58

12065

959.38

... More
Supplying materials and labour for providing R.C.C well curb (1:2:4) including centering and shuttering but excluding the cost of reinforcement all complete job as per specification and direction of E/I.

-

-

-

... More
R.C.C. Well Curb

1.01

5409

5355.59

... More
Providing rough dressed stone masonary in CM (1:6) in staining wall and in the parapet and well around in the platform including shuttering scaffolding if needed and providing adequate number of weep holes from bottem up to 4.5 M GL etc. all complete as per specification & direction of E/I.

-

-

-

... More
In Staining Wall

35.33

97455

2758.43

... More
In Parapet

2.42

6650

2744.71

... More
In Platform outer side wall

1.93

5297

2744.71

... More
Extra for each additional lift of 1m over the initial lift of 3m for masonry work.

-

-

-

... More
In Staining Wall (3-4m)

4.04

91

22.54

... More
In Staining Wall (4-5m)

4.04

182

45.08

... More
In Staining Wall (5-6m)

4.04

273

67.62

... More
In Staining Wall (6-7m)

4.04

364

90.16

... More
In Staining Wall (7-8m)

4.04

455

112.7

... More
In Staining Wall (8-9m)

4.04

546

135.24

... More
Supplying materials and labour fixing 20 mm dia M.S. bar steps in staining wall of 0.3 M interval and fixed with (1:2:4) P.C.C including scaffolding and curing etc. all complete job as per specification & direction of E/I.

16

3391

211.94

... More
Providing P.C.C M150 with nominal mix of (1:2:4) in foundation and plinth with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

-

-

-

... More
In Plateform

1.12

5159

4598.23

... More
Providing R.C.C M20 with nominal mix of (1:1.5:3) in beam of well with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

-

-

-

... More
BEAM

0.28

1471

5218

... More
Providing R.C.C M20 with nominal mix of (1:1.5:3) in roof slab of well with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

1.11

5798

5218

... More
Providing 12 mm thick cement plaster (1:4) with neat cement punning including scaffolding, curing with all leads & lifts of water, taxes & royalty ll complete as per specification & direction of E/I.

52.44

11982

228.49

... More
Providing 8 mm dia to 16 mm diaTor steel reinforcement (Fe 500 grade) of TATA or SAIL or Jindal Make as per approved design and drawing including all labour, materials, taxes etc but excluding cost of carriage of tor rod to work site including cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per specification & direction of E/I.

190

15365

80.87

... More
Supplying equipments and labour for desilting the well complete as per specification & direction of E/I.

1

1578

1578

... More
Supplying equipment and labour for back filling the excavated earth around staing well ll complete as per specification & direction of E/I.

152.73

14345

93.93

... More
Supplying equipment and labour for dewatering including supplying diesel pump set as per requirement and its fuel etc complete as per specification & direction of E/I. 2.0 HP x 8 Hour x 11 days =176

176

7612

43.25

... More
Carriage of Materials

-

-

-

... More
a) Stone Boulder lead- 11 Km (Pakka 1km Kutcha-10km)

63.93

35535

555.85

... More
b) Sand lead -25Km(Pakka 15 km Kutcha-10km)

29.87

19146

641

... More
c) Ston Chips lead - 30Km(Pakka 20 km Kutcha-10km)

3.1

2187

705.8

... More
d) Steel lead - 20 Km(Pakka 10km Kutcha-10km)

0.19

105

556

... More
e) Cement lead - 20 Km(Pakka 10km Kutcha-10km)

8.2

4559

556

... More
Construction RCC Foundation for Steel structure staging & Solar panel .

-

-

-

... More
Earth work in excavation in foundation trenches in ordinary soil and disposal of excavated earth as obtained to a distance up to 50.0m ,including all lifts, levelling ,ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design ,building specification and direction of E/I (vide classification of soil item -B)

4.37

731

167.33

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials ,labour ,royalty and taxes all complete as per building specification and direction of E/I(Mode of measurement compacted volume)

0.24

143

589.51

... More
Providing PCC M-150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I

0.24

1117

4598.23

... More
Providing RCC M-200 in nominal mix of (1:1.5:3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I.

-

-

-

... More
(a)Foundation for Steel structure staging

-

-

-

... More
Footing

0.81

4019

4961.73

... More
Vertical Pedestal

0.56

3375

5989.72

... More
Tie Beam

0.27

1624

5989.72

... More
Providing for steel reinforcement as per approved design and drawing excluding carriage of T.S. bar to work site cutting, bending with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I.

0.16

13503

82096.54

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

3.49

192

55.28

... More
Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.

-

-

-

... More
Cement + Rod (20 KM)

0.95

414

436

... More
Sand (20 KM)

1.03

418

406.24

... More
Stone Chips (20 KM)

1.58

641

406.24

... More
Galvanized tubular Steel structure staging for HDPE water storage Tank& Solar Panel

-

-

-

... More
Providing structural steel galvanised squre pipe section work in trusses, other similar trussed purlins and members with all bracing ,gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge ,including cutting fabricating ,hoisting , erecting and fixing in position , making riveted/bolted /welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & For Structure(PLUS) Providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns (Net wt. of components to be Galv) preferably TATA structural section etc complete.

1039.53

108464

104.34

... More
Information board for IEC

-

-

-

... More
Providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge including cutting fabricating hoisting erecting and fixing in position making reverted bolted welded connections one coat of anticorrosive paint and over it two coats of oil painting etc complete

27.2

2592

95.32

... More
Materials and labour for vinyl painting of matter given by department in different color

1.26

2520

2000

... More
Carriage of Steel Structure due to hilly & unapprocheble Habitation

1

11357

11357.73

... More
Installation of 2000 liters Capacity Water Storage Tank

-

-

-

... More
Providing and fixing HDPE container Syntex or alike one piecemolded water tank made out of low density polythyler andbuilt corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity 2000.00 litres Capacity Water storage Tank

2000

15500

7.75

... More
Transportation Charge

1

1000

1000

... More
Lifting of 2000 Litrs Capacity Tank up to 4.50m height with lifting tools with rope and labour

1

500

500

... More
Making hole in Tank

4

100

25

... More
Making long screw in G.I. pipe including supplying and fitting jam nuts and extra socket etc.

4

634

158.59

... More
Rising and Distribution Network with House Connection up to 10 Nos. including Platform & Stand post

-

-

-

... More
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.

97

14578

150.29

... More
Dismantling plain cement concrete work including stacking serviceable materials in countable stacks within 15 M lead and disposal of unserviceable materials with all leads all complete

1.88

1797

955.89

... More
Providing PCC M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, sticking, curing , taxes and royalty all complete as per specification and direction of E/I. for construction of road cutting portion-

1.88

9328

4961.73

... More
Rising Main

-

-

-

... More
Manufacture, supply and Delivery of following Nominal dia UPVC column pipes including PVC socket (Coupler),

-

-

-

... More
50 mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:87.5 to 88.2mm wall Thickness End:9 .8 mm to 11.9mm, Barrel 7.3mm to 9 mm, Length: 3Mtrs. Delivery Pipe

25

3925

157

... More
Distribution

-

-

-

... More
Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10

-

-

-

... More
50 mm HDPE Pipe-

75

8778

117.04

... More
32 mm HDPE Pipe-

300

14271

47.57

... More
20 mm MDPE Pipe-

200

5000

25

... More
Providing and fixing Gun Metal Gate valve with C I wheel of approved quality(screwed end).

-

-

-

... More
50 mm dia .

1

776

776.07

... More
Providing and supplying High Density Polyethylene (HDPE ) fittings of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10

1

1377

1377.8

... More
Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II.

-

-

-

... More
For Rising

-

-

-

... More
50 mm HDPE Pipe-

25

925

37

... More
Distribution

-

-

-

... More
50 mm HDPE Pipe-

75

2775

37

... More
32 mm HDPE Pipe-

300

6900

23

... More
20 mm MDPE Pipe-

200

2400

12

... More
Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post.

8

960

120.12

... More
Supplying all materials , labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge.

8

108

13.59

... More
Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I.

-

-

-

... More
(1) Elbow

-

-

-

... More
(a) 15 mm dia.

16

1292

80.78

... More
(2) Reducer Socket -

-

-

-

... More
(a) 20 x 15 mm dia.

8

671

83.89

... More
(3) Nipple -

-

-

-

... More
(a) 15 mm dia.

16

1251

78.19

... More
(4) Plain Socket -

-

-

-

... More
(a) 15 mm dia.

16

1231

76.99

... More
Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram.

8

4986

623.29

... More
Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I.

-

-

-

... More
50 mm dia and weight not less than 1.5 Kg.

2

3105

1552.85

... More
Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socket all complete as per specification and direction of E/I.

-

-

-

... More
15 dia and weight not less than 400 Gm

8

1596

199.58

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

-

-

-

... More
Full way valve chamber

1

1712

1712.15

... More
Supplying materials , labours and equipment's for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surface all complete job, as per approved design, specification and direction of E/I.

8

11200

1400

... More
Providing brick masonry chamber of inner size 600 x 600 x 450 mm deep for bore well protection having 125 mm thick wall and 75 mm R.C.C cover including cement plaster of exposed surface, etc all complete job

1

2719

2719

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

82.45

7744

93.93

... More
Providing fitting & fixing 32 mm to 50 mm service HDPE saddle all complete job, as per approved design, specification and direction of E/I.

8

432

54

... More
Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump

-

-

-

... More
Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.

-

-

-

... More
SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.

-

-

-

... More
i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)

-

-

-

... More
ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.

-

-

-

... More
iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.

-

-

-

... More
iv) The module mounting structure should be hot dip galvanized according to IS 4759.

-

-

-

... More
v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided

-

-

-

... More
vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)

-

-

-

... More
vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV

-

-

-

... More
viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.

-

-

-

... More
ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.

-

-

-

... More
x) The motor pump set should have a 5 years warranty.

-

-

-

... More
xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)

-

-

-

... More
xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.

-

-

-

... More
xiii) The system should be as per MNRE guide line & Ecofriendly with suitable arrangement to operate new pump manually.

-

-

-

... More
xiv) With third party inspection before dispatch.

-

-

-

... More
xv) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.

-

-

-

... More
The following details should be marked indelibly on the motor pump set

-

-

-

... More
a) Name of the Manufacturer or Distinctive Logo.

-

-

-

... More
b) Model Number.

-

-

-

... More
c) Serial Number.

-

-

-

... More
Solar submersible motor pump (SPV DC Type)

-

-

-

... More
i) 2 HP (DC Pump) with 1800 wp minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 100 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)

1

170820

170820

... More
Provision of solar night lamp.

1

1000

1000

... More
Annual Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 5 years

-

-

-

... More
O & M Cost for 1st year (Excluding Repair Charges)

1

9000

9000

... More
O & M Cost for 2nd year with Annual Repair Charges

1

9908

9908.28

... More
O & M cost for 3rd Year

1

10502

10502.78

... More
O & M cost for 4th Year

1

11132

11132.95

... More
O & M cost for 5th Year

1

11800

11800.92

... More
Provision of one no SIM card & its recharging cost for RMC

5

4000

800

... More
Tola - Karni (Marchaipat Niche Toli)

-

-

-

... More
Construction of sanitary well 3.0 M internal diameter and 9.0 M deep with 1.0M Platform

-

-

-

... More
Supplying labour and equipment for digging well vide classfication of soil item-B including removing the spoils to a safe distance upto 50m from the edge of the well all complete as per specification and direction of E/I

132.64

21569

162.62

... More
Supplying labour and equipment for digging well vide classfication of soil item-C including removing the spoils to a safe distance upto 50m from the edge of the well all complete as per specification and direction of E/I.

-

-

-

... More
(a) E/W 03 to 04 metre depth below G.L

28.3

17780

628.38

... More
(b) E/W 04 to 05 metre depth below G.L item no. 3.1.67

24.65

17120

694.58

... More
(c) E/W 05 to 06 metre depth below G.L

21.25

16169

760.78

... More
(d) E/W 06 to 07 metre depth below G.L

18.11

14976

826.98

... More
(e) E/W 07 to 08 metre depth below G.L

15.22

13591

893.18

... More
(f) E/W 08 to 09 metre depth below G.L

12.58

12065

959.38

... More
Supplying materials and labour for providing R.C.C well curb (1:2:4) including centering and shuttering but excluding the cost of reinforcement all complete job as per specification and direction of E/I.

-

-

-

... More
R.C.C. Well Curb

1.01

5409

5355.59

... More
Providing rough dressed stone masonary in CM (1:6) in staining wall and in the parapet and well around in the platform including shuttering scaffolding if needed and providing adequate number of weep holes from bottem up to 4.5 M GL etc. all complete as per specification & direction of E/I.

-

-

-

... More
In Staining Wall

35.33

97455

2758.43

... More
In Parapet

2.42

6650

2744.71

... More
In Platform outer side wall

1.93

5297

2744.71

... More
Extra for each additional lift of 1m over the initial lift of 3m for masonry work.

-

-

-

... More
In Staining Wall (3-4m)

4.04

91

22.54

... More
In Staining Wall (4-5m)

4.04

182

45.08

... More
In Staining Wall (5-6m)

4.04

273

67.62

... More
In Staining Wall (6-7m)

4.04

364

90.16

... More
In Staining Wall (7-8m)

4.04

455

112.7

... More
In Staining Wall (8-9m)

4.04

546

135.24

... More
Supplying materials and labour fixing 20 mm dia M.S. bar steps in staining wall of 0.3 M interval and fixed with (1:2:4) P.C.C including scaffolding and curing etc. all complete job as per specification & direction of E/I.

16

3391

211.94

... More
Providing P.C.C M150 with nominal mix of (1:2:4) in foundation and plinth with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

-

-

-

... More
In Plateform

1.12

5159

4598.23

... More
Providing R.C.C M20 with nominal mix of (1:1.5:3) in beam of well with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

-

-

-

... More
BEAM

0.28

1471

5218

... More
Providing R.C.C M20 with nominal mix of (1:1.5:3) in roof slab of well with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

1.11

5798

5218

... More
Providing 12 mm thick cement plaster (1:4) with neat cement punning including scaffolding, curing with all leads & lifts of water, taxes & royalty ll complete as per specification & direction of E/I.

52.44

11982

228.49

... More
Providing 8 mm dia to 16 mm diaTor steel reinforcement (Fe 500 grade) of TATA or SAIL or Jindal Make as per approved design and drawing including all labour, materials, taxes etc but excluding cost of carriage of tor rod to work site including cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per specification & direction of E/I.

190

15365

80.87

... More
Supplying equipments and labour for desilting the well complete as per specification & direction of E/I.

1

1578

1578

... More
Supplying equipment and labour for back filling the excavated earth around staing well ll complete as per specification & direction of E/I.

152.73

14345

93.93

... More
Supplying equipment and labour for dewatering including supplying diesel pump set as per requirement and its fuel etc complete as per specification & direction of E/I. 2.0 HP x 8 Hour x 11 days =176

176

7612

43.25

... More
Carriage of Materials

-

-

-

... More
a) Stone Boulder lead- 11 Km (Pakka 1km Kutcha-10km)

63.93

35535

555.85

... More
b) Sand lead -25Km(Pakka 15 km Kutcha-10km)

29.87

19146

641

... More
c) Ston Chips lead - 30Km(Pakka 20 km Kutcha-10km)

3.1

2187

705.8

... More
d) Steel lead - 20 Km(Pakka 10km Kutcha-10km)

0.19

105

556

... More
e) Cement lead - 20 Km(Pakka 10km Kutcha-10km)

8.2

4559

556

... More
Construction RCC Foundation for Steel structure staging & Solar panel .

-

-

-

... More
Earth work in excavation in foundation trenches in ordinary soil and disposal of excavated earth as obtained to a distance up to 50.0m ,including all lifts, levelling ,ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design ,building specification and direction of E/I (vide classification of soil item -B)

4.37

731

167.33

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials ,labour ,royalty and taxes all complete as per building specification and direction of E/I(Mode of measurement compacted volume)

0.24

143

589.51

... More
Providing PCC M-150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I

0.24

1117

4598.23

... More
Providing RCC M-200 in nominal mix of (1:1.5:3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I.

-

-

-

... More
(a)Foundation for Steel structure staging

-

-

-

... More
Footing

0.81

4019

4961.73

... More
Vertical Pedestal

0.56

3375

5989.72

... More
Tie Beam

0.27

1624

5989.72

... More
Providing for steel reinforcement as per approved design and drawing excluding carriage of T.S. bar to work site cutting, bending with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I.

0.16

13503

82096.54

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

3.49

192

55.28

... More
Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.

-

-

-

... More
Cement + Rod (20 KM)

0.95

414

436

... More
Sand (20 KM)

1.03

418

406.24

... More
Stone Chips (20 KM)

1.58

641

406.24

... More
Galvanized tubular Steel structure staging for HDPE water storage Tank& Solar Panel

-

-

-

... More
Providing structural steel galvanised squre pipe section work in trusses, other similar trussed purlins and members with all bracing ,gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge ,including cutting fabricating ,hoisting , erecting and fixing in position , making riveted/bolted /welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & For Structure(PLUS) Providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns (Net wt. of components to be Galv) preferably TATA structural section etc complete.

1039.53

108464

104.34

... More
Information board for IEC

-

-

-

... More
Providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge including cutting fabricating hoisting erecting and fixing in position making reverted bolted welded connections one coat of anticorrosive paint and over it two coats of oil painting etc complete

27.2

2592

95.32

... More
Materials and labour for vinyl painting of matter given by department in different color

1.26

2520

2000

... More
Carriage of Steel Structure due to hilly & unapprocheble Habitation

1

11357

11357.73

... More
Installation of 2000 liters Capacity Water Storage Tank

-

-

-

... More
Providing and fixing HDPE container Syntex or alike one piecemolded water tank made out of low density polythyler andbuilt corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity 2000.00 litres Capacity Water storage Tank

2000

15500

7.75

... More
Transportation Charge

1

1000

1000

... More
Lifting of 2000 Litrs Capacity Tank up to 4.50m height with lifting tools with rope and labour

1

500

500

... More
Making hole in Tank

4

100

25

... More
Making long screw in G.I. pipe including supplying and fitting jam nuts and extra socket etc.

4

634

158.59

... More
Rising and Distribution Network with House Connection up to 10 Nos. including Platform & Stand post

-

-

-

... More
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.

97

14578

150.29

... More
Dismantling plain cement concrete work including stacking serviceable materials in countable stacks within 15 M lead and disposal of unserviceable materials with all leads all complete

1.88

1797

955.89

... More
Providing PCC M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, sticking, curing , taxes and royalty all complete as per specification and direction of E/I. for construction of road cutting portion-

1.88

9328

4961.73

... More
Rising Main

-

-

-

... More
Manufacture, supply and Delivery of following Nominal dia UPVC column pipes including PVC socket (Coupler),

-

-

-

... More
50 mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:87.5 to 88.2mm wall Thickness End:9 .8 mm to 11.9mm, Barrel 7.3mm to 9 mm, Length: 3Mtrs. Delivery Pipe

25

3925

157

... More
Distribution

-

-

-

... More
Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10

-

-

-

... More
50 mm HDPE Pipe-

75

8778

117.04

... More
32 mm HDPE Pipe-

300

14271

47.57

... More
20 mm MDPE Pipe-

200

5000

25

... More
Providing and fixing Gun Metal Gate valve with C I wheel of approved quality(screwed end).

-

-

-

... More
50 mm dia .

1

776

776.07

... More
Providing and supplying High Density Polyethylene (HDPE ) fittings of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10

1

1377

1377.8

... More
Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II.

-

-

-

... More
For Rising

-

-

-

... More
50 mm HDPE Pipe-

25

925

37

... More
Distribution

-

-

-

... More
50 mm HDPE Pipe-

75

2775

37

... More
32 mm HDPE Pipe-

300

6900

23

... More
20 mm MDPE Pipe-

200

2400

12

... More
Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post.

14

1681

120.12

... More
Supplying all materials , labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge.

14

190

13.59

... More
Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I.

-

-

-

... More
(1) Elbow

-

-

-

... More
(a) 15 mm dia.

28

2261

80.78

... More
(2) Reducer Socket -

-

-

-

... More
(a) 20 x 15 mm dia.

14

1174

83.89

... More
(3) Nipple -

-

-

-

... More
(a) 15 mm dia.

28

2189

78.19

... More
(4) Plain Socket -

-

-

-

... More
(a) 15 mm dia.

28

2155

76.99

... More
Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram.

14

8726

623.29

... More
Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I.

-

-

-

... More
50 mm dia and weight not less than 1.5 Kg.

2

3105

1552.85

... More
Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socket all complete as per specification and direction of E/I.

-

-

-

... More
15 dia and weight not less than 400 Gm

14

2794

199.58

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

-

-

-

... More
Full way valve chamber

1

1712

1712.15

... More
Supplying materials , labours and equipment's for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surface all complete job, as per approved design, specification and direction of E/I.

14

19600

1400

... More
Providing brick masonry chamber of inner size 600 x 600 x 450 mm deep for bore well protection having 125 mm thick wall and 75 mm R.C.C cover including cement plaster of exposed surface, etc all complete job

1

2719

2719

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

82.45

7744

93.93

... More
Providing fitting & fixing 32 mm to 50 mm service HDPE saddle all complete job, as per approved design, specification and direction of E/I.

14

756

54

... More
Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump

-

-

-

... More
Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.

-

-

-

... More
SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.

-

-

-

... More
i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)

-

-

-

... More
ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.

-

-

-

... More
iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.

-

-

-

... More
iv) The module mounting structure should be hot dip galvanized according to IS 4759.

-

-

-

... More
v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided

-

-

-

... More
vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)

-

-

-

... More
vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV

-

-

-

... More
viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.

-

-

-

... More
ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.

-

-

-

... More
x) The motor pump set should have a 5 years warranty.

-

-

-

... More
xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)

-

-

-

... More
xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.

-

-

-

... More
xiii) The system should be as per MNRE guide line & Ecofriendly with suitable arrangement to operate new pump manually.

-

-

-

... More
xiv) With third party inspection before dispatch.

-

-

-

... More
xv) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.

-

-

-

... More
The following details should be marked indelibly on the motor pump set

-

-

-

... More
a) Name of the Manufacturer or Distinctive Logo.

-

-

-

... More
b) Model Number.

-

-

-

... More
c) Serial Number.

-

-

-

... More
Solar submersible motor pump (SPV DC Type)

-

-

-

... More
i) 2 HP (DC Pump) with 1800 wp minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 100 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)

1

170820

170820

... More
Provision of solar night lamp.

1

1000

1000

... More
Annual Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 5 years

-

-

-

... More
O & M Cost for 1st year (Excluding Repair Charges)

1

9000

9000

... More
O & M Cost for 2nd year with Annual Repair Charges

1

9952

9952.78

... More
O & M cost for 3rd Year

1

10549

10549.94

... More
O & M cost for 4th Year

1

11182

11182.94

... More
O & M cost for 5th Year

1

11853

11853.92

... More
Provision of one no SIM card & its recharging cost for RMC

5

4000

800

... More
Tola - Karni (Marchaipat Upper Toli)

-

-

-

... More
Construction of sanitary well 3.0 M internal diameter and 9.0 M deep with 1.0M Platform

-

-

-

... More
Supplying labour and equipment for digging well vide classfication of soil item-B including removing the spoils to a safe distance upto 50m from the edge of the well all complete as per specification and direction of E/I

132.64

21569

162.62

... More
Supplying labour and equipment for digging well vide classfication of soil item-C including removing the spoils to a safe distance upto 50m from the edge of the well all complete as per specification and direction of E/I.

-

-

-

... More
(a) E/W 03 to 04 metre depth below G.L

28.3

17780

628.38

... More
(b) E/W 04 to 05 metre depth below G.L item no. 3.1.67

24.65

17120

694.58

... More
(c) E/W 05 to 06 metre depth below G.L

21.25

16169

760.78

... More
(d) E/W 06 to 07 metre depth below G.L

18.11

14976

826.98

... More
(e) E/W 07 to 08 metre depth below G.L

15.22

13591

893.18

... More
(f) E/W 08 to 09 metre depth below G.L

12.58

12065

959.38

... More
Supplying materials and labour for providing R.C.C well curb (1:2:4) including centering and shuttering but excluding the cost of reinforcement all complete job as per specification and direction of E/I.

-

-

-

... More
R.C.C. Well Curb

1.01

5409

5355.59

... More
Providing rough dressed stone masonary in CM (1:6) in staining wall and in the parapet and well around in the platform including shuttering scaffolding if needed and providing adequate number of weep holes from bottem up to 4.5 M GL etc. all complete as per specification & direction of E/I.

-

-

-

... More
In Staining Wall

35.33

97455

2758.43

... More
In Parapet

2.42

6650

2744.71

... More
In Platform outer side wall

1.93

5297

2744.71

... More
Extra for each additional lift of 1m over the initial lift of 3m for masonry work.

-

-

-

... More
In Staining Wall (3-4m)

4.04

91

22.54

... More
In Staining Wall (4-5m)

4.04

182

45.08

... More
In Staining Wall (5-6m)

4.04

273

67.62

... More
In Staining Wall (6-7m)

4.04

364

90.16

... More
In Staining Wall (7-8m)

4.04

455

112.7

... More
In Staining Wall (8-9m)

4.04

546

135.24

... More
Supplying materials and labour fixing 20 mm dia M.S. bar steps in staining wall of 0.3 M interval and fixed with (1:2:4) P.C.C including scaffolding and curing etc. all complete job as per specification & direction of E/I.

16

3391

211.94

... More
Providing P.C.C M150 with nominal mix of (1:2:4) in foundation and plinth with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

-

-

-

... More
In Plateform

1.12

5159

4598.23

... More
Providing R.C.C M20 with nominal mix of (1:1.5:3) in beam of well with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

-

-

-

... More
BEAM

0.28

1471

5218

... More
Providing R.C.C M20 with nominal mix of (1:1.5:3) in roof slab of well with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

1.11

5798

5218

... More
Providing 12 mm thick cement plaster (1:4) with neat cement punning including scaffolding, curing with all leads & lifts of water, taxes & royalty ll complete as per specification & direction of E/I.

52.44

11982

228.49

... More
Providing 8 mm dia to 16 mm diaTor steel reinforcement (Fe 500 grade) of TATA or SAIL or Jindal Make as per approved design and drawing including all labour, materials, taxes etc but excluding cost of carriage of tor rod to work site including cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per specification & direction of E/I.

190

15365

80.87

... More
Supplying equipments and labour for desilting the well complete as per specification & direction of E/I.

1

1578

1578

... More
Supplying equipment and labour for back filling the excavated earth around staing well ll complete as per specification & direction of E/I.

152.73

14345

93.93

... More
Supplying equipment and labour for dewatering including supplying diesel pump set as per requirement and its fuel etc complete as per specification & direction of E/I. 2.0 HP x 8 Hour x 11 days =176

176

7612

43.25

... More
Carriage of Materials

-

-

-

... More
a) Stone Boulder lead- 11 Km (Pakka 1km Kutcha-10km)

63.93

35535

555.85

... More
b) Sand lead -25Km(Pakka 15 km Kutcha-10km)

29.87

19146

641

... More
c) Ston Chips lead - 30Km(Pakka 20 km Kutcha-10km)

3.1

2187

705.8

... More
d) Steel lead - 20 Km(Pakka 10km Kutcha-10km)

0.19

105

556

... More
e) Cement lead - 20 Km(Pakka 10km Kutcha-10km)

8.2

4559

556

... More
Construction RCC Foundation for Steel structure staging & Solar panel .

-

-

-

... More
Earth work in excavation in foundation trenches in ordinary soil and disposal of excavated earth as obtained to a distance up to 50.0m ,including all lifts, levelling ,ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design ,building specification and direction of E/I (vide classification of soil item -B)

4.37

731

167.33

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials ,labour ,royalty and taxes all complete as per building specification and direction of E/I(Mode of measurement compacted volume)

0.24

143

589.51

... More
Providing PCC M-150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I

0.24

1117

4598.23

... More
Providing RCC M-200 in nominal mix of (1:1.5:3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I.

-

-

-

... More
(a)Foundation for Steel structure staging

-

-

-

... More
Footing

0.81

4019

4961.73

... More
Vertical Pedestal

0.56

3375

5989.72

... More
Tie Beam

0.27

1624

5989.72

... More
Providing for steel reinforcement as per approved design and drawing excluding carriage of T.S. bar to work site cutting, bending with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I.

0.16

13503

82096.54

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

3.49

192

55.28

... More
Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.

-

-

-

... More
Cement + Rod (20 KM)

0.95

414

436

... More
Sand (20 KM)

1.03

418

406.24

... More
Stone Chips (20 KM)

1.58

641

406.24

... More
Galvanized tubular Steel structure staging for HDPE water storage Tank& Solar Panel

-

-

-

... More
Providing structural steel galvanised squre pipe section work in trusses, other similar trussed purlins and members with all bracing ,gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge ,including cutting fabricating ,hoisting , erecting and fixing in position , making riveted/bolted /welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & For Structure(PLUS) Providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns (Net wt. of components to be Galv) preferably TATA structural section etc complete.

1039.53

108464

104.34

... More
Information board for IEC

-

-

-

... More
Providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge including cutting fabricating hoisting erecting and fixing in position making reverted bolted welded connections one coat of anticorrosive paint and over it two coats of oil painting etc complete

27.2

2592

95.32

... More
Materials and labour for vinyl painting of matter given by department in different color

1.26

2520

2000

... More
Carriage of Steel Structure due to hilly & unapprocheble Habitation

1

11357

11357.73

... More
Installation of 2000 liters Capacity Water Storage Tank

-

-

-

... More
Providing and fixing HDPE container Syntex or alike one piecemolded water tank made out of low density polythyler andbuilt corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity 2000.00 litres Capacity Water storage Tank

2000

15500

7.75

... More
Transportation Charge

1

1000

1000

... More
Lifting of 2000 Litrs Capacity Tank up to 4.50m height with lifting tools with rope and labour

1

500

500

... More
Making hole in Tank

4

100

25

... More
Making long screw in G.I. pipe including supplying and fitting jam nuts and extra socket etc.

4

634

158.59

... More
Rising and Distribution Network with House Connection up to 10 Nos. including Platform & Stand post

-

-

-

... More
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.

97

14578

150.29

... More
Dismantling plain cement concrete work including stacking serviceable materials in countable stacks within 15 M lead and disposal of unserviceable materials with all leads all complete

1.88

1797

955.89

... More
Providing PCC M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, sticking, curing , taxes and royalty all complete as per specification and direction of E/I. for construction of road cutting portion-

1.88

9328

4961.73

... More
Rising Main

-

-

-

... More
Manufacture, supply and Delivery of following Nominal dia UPVC column pipes including PVC socket (Coupler),

-

-

-

... More
50 mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:87.5 to 88.2mm wall Thickness End:9 .8 mm to 11.9mm, Barrel 7.3mm to 9 mm, Length: 3Mtrs. Delivery Pipe

25

3925

157

... More
Distribution

-

-

-

... More
Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10

-

-

-

... More
50 mm HDPE Pipe-

75

8778

117.04

... More
32 mm HDPE Pipe-

300

14271

47.57

... More
20 mm MDPE Pipe-

200

5000

25

... More
Providing and fixing Gun Metal Gate valve with C I wheel of approved quality(screwed end).

-

-

-

... More
50 mm dia .

1

776

776.07

... More
Providing and supplying High Density Polyethylene (HDPE ) fittings of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10

1

1377

1377.8

... More
Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II.

-

-

-

... More
For Rising

-

-

-

... More
50 mm HDPE Pipe-

25

925

37

... More
Distribution

-

-

-

... More
50 mm HDPE Pipe-

75

2775

37

... More
32 mm HDPE Pipe-

300

6900

23

... More
20 mm MDPE Pipe-

200

2400

12

... More
Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post.

13

1561

120.12

... More
Supplying all materials , labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge.

13

176

13.59

... More
Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I.

-

-

-

... More
(1) Elbow

-

-

-

... More
(a) 15 mm dia.

26

2100

80.78

... More
(2) Reducer Socket -

-

-

-

... More
(a) 20 x 15 mm dia.

13

1090

83.89

... More
(3) Nipple -

-

-

-

... More
(a) 15 mm dia.

26

2032

78.19

... More
(4) Plain Socket -

-

-

-

... More
(a) 15 mm dia.

26

2001

76.99

... More
Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram.

13

8102

623.29

... More
Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I.

-

-

-

... More
50 mm dia and weight not less than 1.5 Kg.

2

3105

1552.85

... More
Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socket all complete as per specification and direction of E/I.

-

-

-

... More
15 dia and weight not less than 400 Gm

13

2594

199.58

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

-

-

-

... More
Full way valve chamber

1

1712

1712.15

... More
Supplying materials , labours and equipment's for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surface all complete job, as per approved design, specification and direction of E/I.

13

18200

1400

... More
Providing brick masonry chamber of inner size 600 x 600 x 450 mm deep for bore well protection having 125 mm thick wall and 75 mm R.C.C cover including cement plaster of exposed surface, etc all complete job

1

2719

2719

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

82.45

7744

93.93

... More
Providing fitting & fixing 32 mm to 50 mm service HDPE saddle all complete job, as per approved design, specification and direction of E/I.

13

702

54

... More
Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump

-

-

-

... More
Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.

-

-

-

... More
SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.

-

-

-

... More
i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)

-

-

-

... More
ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.

-

-

-

... More
iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.

-

-

-

... More
iv) The module mounting structure should be hot dip galvanized according to IS 4759.

-

-

-

... More
v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided

-

-

-

... More
vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)

-

-

-

... More
vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV

-

-

-

... More
viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.

-

-

-

... More
ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.

-

-

-

... More
x) The motor pump set should have a 5 years warranty.

-

-

-

... More
xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)

-

-

-

... More
xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.

-

-

-

... More
xiii) The system should be as per MNRE guide line & Ecofriendly with suitable arrangement to operate new pump manually.

-

-

-

... More
xiv) With third party inspection before dispatch.

-

-

-

... More
xv) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.

-

-

-

... More
The following details should be marked indelibly on the motor pump set

-

-

-

... More
a) Name of the Manufacturer or Distinctive Logo.

-

-

-

... More
b) Model Number.

-

-

-

... More
c) Serial Number.

-

-

-

... More
Solar submersible motor pump (SPV DC Type)

-

-

-

... More
i) 2 HP (DC Pump) with 1800 wp minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 100 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)

1

170820

170820

... More
Provision of solar night lamp.

1

1000

1000

... More
Annual Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 5 years

-

-

-

... More
O & M Cost for 1st year (Excluding Repair Charges)

1

9000

9000

... More
O & M Cost for 2nd year with Annual Repair Charges

1

9945

9945.36

... More
O & M cost for 3rd Year

1

10542

10542.08

... More
O & M cost for 4th Year

1

11174

11174.61

... More
O & M cost for 5th Year

1

11845

11845.09

... More
Provision of one no SIM card & its recharging cost for RMC

5

4000

800

... More
Tola - Dahkul (Jatradipa)

-

-

-

... More
CONSTRUCTION OF DEEP DRILLED TUBE WELL OF 125/115 MM DIA, 90 MTRS

-

-

-

... More
Drilling Portion

-

-

-

... More
Construction for 115/125 mm dia drilled Tube-Well for drilling in all kinds of soil rock for installation of hand pump with D.T.H Rig machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant for making 125/115 mm dia boring etcand cost of transporting rig machine and other vehicle up to site work as per specification and direction of Engineer-in-charge.

-

-

-

... More
(a) Up to 30mtr. Depth bellow G.L. in Rural Areas

30

14025

467.5

... More
(b) Beyond 30mtr. In Rural Areas

60

30228

503.8

... More
Providing all equipments and labour for lowering 125mm dia blue UPVC Casing pipe as casing for protecting the side from falling during the process of drilling all complete job including carriage of material to work site.

1

15

15.45

... More
Supplying labour cement and calcium chloride or bentonite solution and equipments for Grouting to Casing Pipe all complete job including carriage of material to work site as per specification & direction of E/I

1

172

172.7

... More
Supplying all tools, equipments and labour and doing washing, flushing, and developing of drilled tube well to give clean and clear water all complete job as per direction of E/I.

0.5

1962

3925.18

... More
Supplying all materials labours and equipment including 125 mm dia GI/CI cap 125 mm dia T/W properly all complete and taking it out as per specification & direction of E/I. (the cap will be property of department)

1

154

154

... More
COST OF MATERIALS

-

-

-

... More
Cost of 125 mm dia blue UPVC Casing Pipe as per I.S.12818/2016 CML no.- 5543459

18

10292

571.83

... More
Construction RCC Foundation for Steel structure staging & Solar panel .

-

-

-

... More
Earth work in excavation in foundation trenches in ordinary soil and disposal of excavated earth as obtained to a distance up to 50.0m ,including all lifts, levelling ,ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design ,building specification and direction of E/I(vide classification of soil item -B)

8.75

1464

167.33

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials ,labour ,royalty and taxes all complete as per building specification and direction of E/I(Mode of measurement compacted volume)

0.47

275

589.51

... More
Providing nominal mix PCC of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I

0.47

2633

5626.21

... More
Providing RCC M-20 in nominal mix of (1:1.5:3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I.

-

-

-

... More
(a)Foundation for Steel structure staging

-

-

-

... More
Footing and Vertical Pedestal

-

-

-

... More
Raft

2.36

11725

4961.73

... More
Column

0.74

3379

4598.23

... More
Tie Beam

0.39

1793

4598.23

... More
Providing for steel reinforcement as per approved design and drawing excluding carriage of T.S. bar to work site cutting, bending with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I.

0.42

34316

82096.54

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

7.44

411

55.28

... More
Carraige of Materials

-

-

-

... More
Cement 20 KM lead

1.6

695

436

... More
Steel 20 KM lead

1.88

819

436

... More
Sand 20 KM lead

1.88

763

406.24

... More
Stone chips 20 KM lead

3.37

1369

406.24

... More
Galvanized tubular Steel structure staging for HDPE water storage Tank& Solar Panel

-

-

-

... More
Providing structural steel galvanised squre pipe section work in trusses, other similar trussed purlins and members with all bracing ,gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge ,including cutting fabricating ,hoisting , erecting and fixing in position , making riveted/bolted /welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & For Structure(PLUS) Providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns (Net wt. of components to be Galv) preferably TATA structural section etc complete.

1571.77

163998

104.34

... More
Information board for IEC

-

-

-

... More
Providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge including cutting fabricating hoisting erecting and fixing in position making reverted bolted welded connections one coat of anticorrosive paint and over it two coats of oil painting etc complete

27.2

2592

95.32

... More
Materials and labour for vinyl painting of matter given by department in different color

1.26

2520

2000

... More
Installation of 5000 liters Capacity Water Storage Tank

-

-

-

... More
Providing and fixing HDPE container Syntex or alike one piecemolded water tank made out of low density polythyler andbuilt corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity 5000.00 litres Capacity Water storage Tank

5000

38750

7.75

... More
Transportation Charge

1

1000

1000

... More
Lifting of 5000 Litrs Capacity Tank up to 6.00m height with lifting tools with rope and labour

1

500

500

... More
Making hole in Tank

4

100

25

... More
Making long screw in G.I. pipe including supplying and fitting jam nuts and extra socket etc.

4

634

158.59

... More
Rising and Distribution Network with House Connection up to 10 Nos. including Platform & Stand post

-

-

-

... More
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.

102.5

15404

150.29

... More
Dismantling plain cement concrete work including stacking serviceable materials in countable stacks within 15 M lead and disposal of unserviceable materials with all leads all complete

3.75

3584

955.89

... More
Providing PCC M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, sticking, curing , taxes and royalty all complete as per specification and direction of E/I. for construction of road cutting portion-

3.75

18606

4961.73

... More
Rising Main

-

-

-

... More
Manufacture, supply and Delivery of following Nominal dia UPVC column pipes including PVC socket (Coupler),

-

-

-

... More
50 mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:87.5 to 88.2mm wall Thickness End:9 .8 mm to 11.9mm, Barrel 7.3mm to 9 mm, Length: 3Mtrs. Delivery Pipe

30

4710

157

... More
Distribution

-

-

-

... More
Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties.

-

-

-

... More
50 mm HDPE Pipe-

100

11704

117.04

... More
32 mm HDPE Pipe-

250

11892

47.57

... More
20 mm MDPE Pipe-

250

6250

25

... More
Providing and fixing Gun Metal Gate valve with C I wheel of approved quality(screwed end).

-

-

-

... More
50 mm dia .

2

1552

776.07

... More
Providing and supplying High Density Polyethylene (HDPE ) fittings of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties.

1

1795

1795.4

... More
Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II.

-

-

-

... More
For Rising

-

-

-

... More
50 mm HDPE Pipe-

30

1110

37

... More
Distribution

-

-

-

... More
50 mm HDPE Pipe-

100

3700

37

... More
32 mm HDPE Pipe-

250

5750

23

... More
20 mm HDPE Pipe-

250

3000

12

... More
Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post.

24

2882

120.12

... More
Supplying all materials , labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge.

24

326

13.59

... More
Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I.

-

-

-

... More
(1) Elbow

-

-

-

... More
(a) 15 mm dia.

48

3877

80.78

... More
(2) Reducer Socket -

-

-

-

... More
(a) 20 x 15 mm dia.

24

2013

83.89

... More
(3) Nipple -

-

-

-

... More
(a) 15 mm dia.

48

3753

78.19

... More
(4) Plain Socket -

-

-

-

... More
(a) 15 mm dia.

48

3695

76.99

... More
Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram.

24

14958

623.29

... More
Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I.

-

-

-

... More
50 mm dia and weight not less than 1.5 Kg.

1

1552

1552.85

... More
Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socket all complete as per specification and direction of E/I.

-

-

-

... More
15 dia and weight not less than 400 Gm

24

4789

199.58

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

-

-

-

... More
Full way valve chamber

2

3424

1712.15

... More
Supplying materials , labours and equipment's for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surface all complete job, as per approved design, specification and direction of E/I.

24

33600

1400

... More
Providing brick masonry chamber of inner size 600 x 600 x 450 mm deep for bore well protection having 125 mm thick wall and 75 mm R.C.C cover including cement plaster of exposed surface, etc all complete job

1

2719

2719

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

87.13

7520

86.32

... More
Providing fitting & fixing 32 mm to 50 mm service HDPE saddle all complete job, as per approved design, specification and direction of E/I.

24

1296

54

... More
Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump

-

-

-

... More
Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.

-

-

-

... More
SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.

-

-

-

... More
i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)

-

-

-

... More
ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.

-

-

-

... More
iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.

-

-

-

... More
iv) The module mounting structure should be hot dip galvanized according to IS 4759.

-

-

-

... More
v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided

-

-

-

... More
vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)

-

-

-

... More
vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV

-

-

-

... More
viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.

-

-

-

... More
ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.

-

-

-

... More
x) The motor pump set should have a 5 years warranty.

-

-

-

... More
xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)

-

-

-

... More
xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.

-

-

-

... More
xiii) The system should be as per MNRE guide line & Eco-friendly with suitable arrangement to operate new pump manually.

-

-

-

... More
xiv) With third party inspection before dispatch.

-

-

-

... More
xv) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.

-

-

-

... More
The following details should be marked indelibly on the motor pump set

-

-

-

... More
a) Name of the Manufacturer or Distinctive Logo.

-

-

-

... More
b) Model Number.

-

-

-

... More
c) Serial Number.

-

-

-

... More
Solar submersible motor pump (SPV DC Type)

-

-

-

... More
i) 1 HP (DC Pump) with 900 WP minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 120 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)

1

119000

119000

... More
Carrying out recuperation/Yield Test for ascertaining the discharge of constructed well/ excavated profile as directed by the IEC. The test out by the drawing down water from the well/ profile below normal/subsoil water level up to full depth rise is recorded the normal water level/subsoil water level in the well / profile as well as strainer/level at pump as per design of W.S. scheme shall be recorded prior to the test including cost of all materials, over Load , Labours etc. complete as directed.

1

1865

1865

... More
Provision of solar night lamp.

1

1000

1000

... More
Annual Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 5 years

-

-

-

... More
O & M Cost for 1st year (Excluding Repair Charges)

1

9000

9000

... More
O & M Cost for 2nd year with Annual Repair Charges

1

10183

10183.6

... More
O & M cost for 3rd Year

1

10794

10794.61

... More
O & M cost for 4th Year

1

11442

11442.29

... More
O & M cost for 5th Year

1

12128

12128.83

... More
Provision of one no SIM card & its recharging cost for RMC

5

4000

800

... More
Tola - Kothi (Pahar Panari)

-

-

-

... More
Construction of 300 mm x 125 mm x 90.00 m deep GPT Bore well

-

-

-

... More
Cost of Transportation and other miscellanies charge ,for setting the ring machine at site etc all complete job as per direction of E/I.

1

4950

4950

... More
Drilling of 300mm dia perfectly vertical bore hole, by mechanical Rotary Rig Machine for the specified depth below ground level in all types of soil, moorum, etc which solid core cannot be retained ,having unconfined aquifer, including all works pertaining to it and bending the casing pipe, at least 0.30m(from 0to 48meters depth below ground level as per direction of E/I 0.00m to 48.00m(av. depth).

60

50820

847

... More
Drilling in all kinds of soil and rock in rural areas with D.T.H. Rig Machine, all complete including supplying of all materials, labour, tools, drilling rig machine ,air compressor and equipment’s as well as fuel, lubricants for making 115mmdia boring and cost of transportation charge of rig machine and other vehicle to site the work site as per specification & direction of E/I.

30

15114

503.8

... More
Cost of 125 mm dia blue UPVC Casing Pipe as per IS:12818:2016 CML no- 5543459.

48

27447

571.83

... More
Supplying all materials, labour and inserting UPVC blue pipe 125 mm internal dia casing pipe for protecting the bore hole in over burden up to hard surface as per IS 12818-1392 with latest revision all complete job with taxes as per specification and direction of E/I Supplying all materials, labour and inserting UPVC blue pipe 125 mm internal dia casing pipe for protecting the bore hole in over burden up to hard surface as per IS 12818-1392 with latest revision all complete job with taxes as per specification and direction of E/I.

48

741

15.45

... More
Providing and fixing centralizing guide to the well assembly at each and of slotted pipe to keep the assembly in the center of the hole so that to provide an even thickness of gravel pack.

3

450

150

... More
Supplying labours and equipment’s including 125mm dia G.I. Cap & fitting and fixing over the casing pipe of bore well properly and taking it out as per direction of E/I (The Cap will be the property of Contractor)Supplying labours and equipment’s including 125mm dia G.I. Cap & fitting and fixing over the casing pipe of bore well properly and taking it out as per direction of E/I (The Cap will be the property of Contractor).

1

154

154

... More
Providing gravel packing with approved best quality gravel in uniformly graded size between 3.16mm(1/8’’)to 9.53mm(3/8’’) including collection ,stacking ,washing &packing in the annular space between the bore hole and the other surface of casing pipe in layer of suitable thickness in the under space as required rate by manual , including all lead& lift ,tec. All complete as per direction of E/I.

2.55

4628

1815

... More
Providing & supplying all labours, tools and plant for developing the gravel packed T/Well by use of compressed air for minimum 8 hours complete to make T/Well free from sand as per direction of E/I.

1

6600

6600

... More
Supplying of 125 mm dia. Ribbed screen pipe confirming to IS:12818:2016 (CML no- 1543459) latest revision including carriage.

15

10931

728.75

... More
Construction RCC Foundation for Steel structure staging & Solar panel .

-

-

-

... More
Earth work in excavation in foundation trenches in ordinary soil and disposal of excavated earth as obtained to a distance up to 50.0m ,including all lifts, levelling ,ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design ,building specification and direction of E/I (vide classification of soil item -B)

4.37

731

167.33

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials ,labour ,royalty and taxes all complete as per building specification and direction of E/I(Mode of measurement compacted volume)

0.24

143

589.51

... More
Providing PCC M-150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I

0.24

1117

4598.23

... More
Providing RCC M-200 in nominal mix of (1:1.5:3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I.

-

-

-

... More
(a)Foundation for Steel structure staging

-

-

-

... More
Footing

0.81

4019

4961.73

... More
Vertical Pedestal

0.56

3375

5989.72

... More
Tie Beam

0.27

1624

5989.72

... More
Providing for steel reinforcement as per approved design and drawing excluding carriage of T.S. bar to work site cutting, bending with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I.

0.16

13503

82096.54

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

3.49

192

55.28

... More
Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.

-

-

-

... More
Cement + Rod (20 KM)

0.95

414

436

... More
Sand (20 KM)

1.03

418

406.24

... More
Stone Chips (20 KM)

1.58

641

406.24

... More
Galvanized tubular Steel structure staging for HDPE water storage Tank& Solar Panel

-

-

-

... More
Providing structural steel galvanised squre pipe section work in trusses, other similar trussed purlins and members with all bracing ,gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge ,including cutting fabricating ,hoisting , erecting and fixing in position , making riveted/bolted /welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & For Structure(PLUS) Providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns (Net wt. of components to be Galv) preferably TATA structural section etc complete.

1039.53

108464

104.34

... More
Information board for IEC

-

-

-

... More
Providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge including cutting fabricating hoisting erecting and fixing in position making reverted bolted welded connections one coat of anticorrosive paint and over it two coats of oil painting etc complete

27.2

2592

95.32

... More
Materials and labour for vinyl painting of matter given by department in different color

1.26

2520

2000

... More
Installation of 2000 liters Capacity Water Storage Tank

-

-

-

... More
Providing and fixing HDPE container Syntex or alike one piecemolded water tank made out of low density polythyler andbuilt corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity 2000.00 litres Capacity Water storage Tank

2000

15500

7.75

... More
Transportation Charge

1

1000

1000

... More
Lifting of 2000 Litrs Capacity Tank up to 4.50m height with lifting tools with rope and labour

1

500

500

... More
Making hole in Tank

4

100

25

... More
Making long screw in G.I. pipe including supplying and fitting jam nuts and extra socket etc.

4

634

158.59

... More
Rising and Distribution Network with House Connection up to 10 Nos. including Platform & Stand post

-

-

-

... More
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.

51.15

7687

150.29

... More
Dismantling plain cement concrete work including stacking serviceable materials in countable stacks within 15 M lead and disposal of unserviceable materials with all leads all complete

2.25

2150

955.89

... More
Providing PCC M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, sticking, curing , taxes and royalty all complete as per specification and direction of E/I. for construction of road cutting portion-

2.25

11163

4961.73

... More
Rising Main

-

-

-

... More
Manufacture, supply and Delivery of following Nominal dia UPVC column pipes including PVC socket (Coupler),

-

-

-

... More
50 mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:87.5 to 88.2mm wall Thickness End:9 .8 mm to 11.9mm, Barrel 7.3mm to 9 mm, Length: 3Mtrs. Delivery Pipe

25

3925

157

... More
Distribution

-

-

-

... More
Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10

-

-

-

... More
50 mm HDPE Pipe-

50

5852

117.04

... More
32 mm HDPE Pipe-

90

4281

47.57

... More
20 mm MDPE Pipe-

150

3750

25

... More
Providing and fixing Gun Metal Gate valve with C I wheel of approved quality(screwed end).

-

-

-

... More
50 mm dia .

1

776

776.07

... More
Providing and supplying High Density Polyethylene (HDPE ) fittings of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10

1

960

960.2

... More
Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II.

-

-

-

... More
For Rising

-

-

-

... More
50 mm HDPE Pipe-

25

925

37

... More
Distribution

-

-

-

... More
50 mm HDPE Pipe-

50

1850

37

... More
32 mm HDPE Pipe-

90

2070

23

... More
20 mm MDPE Pipe-

150

1800

12

... More
Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post.

8

960

120.12

... More
Supplying all materials , labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge.

8

108

13.59

... More
Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I.

-

-

-

... More
(1) Elbow

-

-

-

... More
(a) 15 mm dia.

16

1292

80.78

... More
(2) Reducer Socket -

-

-

-

... More
(a) 20 x 15 mm dia.

8

671

83.89

... More
(3) Nipple -

-

-

-

... More
(a) 15 mm dia.

16

1251

78.19

... More
(4) Plain Socket -

-

-

-

... More
(a) 15 mm dia.

16

1231

76.99

... More
Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram.

8

4986

623.29

... More
Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I.

-

-

-

... More
50 mm dia and weight not less than 1.5 Kg.

2

3105

1552.85

... More
Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socket all complete as per specification and direction of E/I.

-

-

-

... More
15 dia and weight not less than 400 Gm

8

1596

199.58

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

-

-

-

... More
Full way valve chamber

1

1712

1712.15

... More
Supplying materials , labours and equipment's for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surface all complete job, as per approved design, specification and direction of E/I.

8

11200

1400

... More
Providing brick masonry chamber of inner size 600 x 600 x 450 mm deep for bore well protection having 125 mm thick wall and 75 mm R.C.C cover including cement plaster of exposed surface, etc all complete job

1

2719

2719

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

43.48

4083

93.93

... More
Providing fitting & fixing 32 mm to 50 mm service HDPE saddle all complete job, as per approved design, specification and direction of E/I.

8

432

54

... More
Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump

-

-

-

... More
Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.

-

-

-

... More
SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.

-

-

-

... More
i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)

-

-

-

... More
ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.

-

-

-

... More
iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.

-

-

-

... More
iv) The module mounting structure should be hot dip galvanized according to IS 4759.

-

-

-

... More
v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided

-

-

-

... More
vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)

-

-

-

... More
vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV

-

-

-

... More
viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.

-

-

-

... More
ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.

-

-

-

... More
x) The motor pump set should have a 5 years warranty.

-

-

-

... More
xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)

-

-

-

... More
xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.

-

-

-

... More
xiii) The system should be as per MNRE guide line & Eco-friendly with suitable arrangement to operate new pump manually.

-

-

-

... More
xiv) With third party inspection before dispatch.

-

-

-

... More
xv) Fitting, fixing & mounting on water tank steel structure.

-

-

-

... More
xvi) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.

-

-

-

... More
The following details should be marked indelibly on the motor pump set

-

-

-

... More
a) Name of the Manufacturer or Distinctive Logo.

-

-

-

... More
b) Model Number.

-

-

-

... More
c) Serial Number.

-

-

-

... More
Solar submersible motor pump (SPV DC Type)

-

-

-

... More
i) 1 HP (DC Pump) with 900 WP minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 120 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)

1

119000

119000

... More
Carrying out recuperation/Yield Test for ascertaining the discharge of constructed well/ excavated profile as directed by the IEC. The test out by the drawing down water from the well/ profile below normal/subsoil water level up to full depth rise is recorded the normal water level/subsoil water level in the well / profile as well as strainer/level at pump as per design of W.S. scheme shall be recorded prior to the test including cost of all materials, over Load , Labours etc. complete as directed.

1

1865

1865

... More
Provision of solar night lamp.

1

1000

1000

... More
Annual Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 5 years

-

-

-

... More
O & M Cost for 1st year (Excluding Repair Charges)

1

9000

9000

... More
O & M Cost for 2nd year with Annual Repair Charges

1

9835

9835.03

... More
O & M cost for 3rd Year

1

10425

10425.13

... More
O & M cost for 4th Year

1

11050

11050.64

... More
O & M cost for 5th Year

1

11713

11713.68

... More
Provision of one no SIM card & its recharging cost for RMC

5

4000

800

... More
Tola - Mahuadih (Khas)

-

-

-

... More
CONSTRUCTION OF DEEP DRILLED TUBE WELL OF 125/115 MM DIA, 90 MTRS

-

-

-

... More
Drilling Portion

-

-

-

... More
Construction for 115/125 mm dia drilled Tube-Well for drilling in all kinds of soil rock for installation of hand pump with D.T.H Rig machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant for making 125/115 mm dia boring etcand cost of transporting rig machine and other vehicle up to site work as per specification and direction of Engineer-in-charge.

-

-

-

... More
(a) Up to 30mtr. Depth bellow G.L. in Rural Areas

30

14025

467.5

... More
(b) Beyond 30mtr. In Rural Areas

60

30228

503.8

... More
Providing all equipments and labour for lowering 125mm dia blue UPVC Casing pipe as casing for protecting the side from falling during the process of drilling all complete job including carriage of material to work site.

1

15

15.45

... More
Supplying labour cement and calcium chloride or bentonite solution and equipments for Grouting to Casing Pipe all complete job including carriage of material to work site as per specification & direction of E/I

1

172

172.7

... More
Supplying all tools, equipments and labour and doing washing, flushing, and developing of drilled tube well to give clean and clear water all complete job as per direction of E/I.

0.5

1962

3925.18

... More
Supplying all materials labours and equipment including 125 mm dia GI/CI cap 125 mm dia T/W properly all complete and taking it out as per specification & direction of E/I. (the cap will be property of department)

1

154

154

... More
COST OF MATERIALS

-

-

-

... More
Cost of 125 mm dia blue UPVC Casing Pipe as per I.S.12818/2016 CML no.- 5543459

18

10292

571.83

... More
Construction RCC Foundation for Steel structure staging & Solar panel .

-

-

-

... More
Earth work in excavation in foundation trenches in ordinary soil and disposal of excavated earth as obtained to a distance up to 50.0m ,including all lifts, levelling ,ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design ,building specification and direction of E/I(vide classification of soil item -B)

8.75

1464

167.33

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials ,labour ,royalty and taxes all complete as per building specification and direction of E/I(Mode of measurement compacted volume)

0.47

275

589.51

... More
Providing nominal mix PCC of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I

0.47

2633

5626.21

... More
Providing RCC M-20 in nominal mix of (1:1.5:3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I.

-

-

-

... More
(a)Foundation for Steel structure staging

-

-

-

... More
Footing and Vertical Pedestal

-

-

-

... More
Raft

2.36

11725

4961.73

... More
Column

0.74

3379

4598.23

... More
Tie Beam

0.39

1793

4598.23

... More
Providing for steel reinforcement as per approved design and drawing excluding carriage of T.S. bar to work site cutting, bending with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I.

0.42

34316

82096.54

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

7.44

411

55.28

... More
Carraige of Materials

-

-

-

... More
Cement 20 KM lead

1.6

695

436

... More
Steel 20 KM lead

1.88

819

436

... More
Sand 20 KM lead

1.88

763

406.24

... More
Stone chips 20 KM lead

3.37

1369

406.24

... More
Galvanized tubular Steel structure staging for HDPE water storage Tank& Solar Panel

-

-

-

... More
Providing structural steel galvanised squre pipe section work in trusses, other similar trussed purlins and members with all bracing ,gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge ,including cutting fabricating ,hoisting , erecting and fixing in position , making riveted/bolted /welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & For Structure(PLUS) Providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns (Net wt. of components to be Galv) preferably TATA structural section etc complete.

1571.77

163998

104.34

... More
Information board for IEC

-

-

-

... More
Providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge including cutting fabricating hoisting erecting and fixing in position making reverted bolted welded connections one coat of anticorrosive paint and over it two coats of oil painting etc complete

27.2

2592

95.32

... More
Materials and labour for vinyl painting of matter given by department in different color

1.26

2520

2000

... More
Installation of 5000 liters Capacity Water Storage Tank

-

-

-

... More
Providing and fixing HDPE container Syntex or alike one piecemolded water tank made out of low density polythyler andbuilt corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity 5000.00 litres Capacity Water storage Tank

5000

38750

7.75

... More
Transportation Charge

1

1000

1000

... More
Lifting of 5000 Litrs Capacity Tank up to 6.00m height with lifting tools with rope and labour

1

500

500

... More
Making hole in Tank

4

100

25

... More
Making long screw in G.I. pipe including supplying and fitting jam nuts and extra socket etc.

4

634

158.59

... More
Rising and Distribution Network with House Connection up to 10 Nos. including Platform & Stand post

-

-

-

... More
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.

102.5

15404

150.29

... More
Dismantling plain cement concrete work including stacking serviceable materials in countable stacks within 15 M lead and disposal of unserviceable materials with all leads all complete

3.75

3584

955.89

... More
Providing PCC M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, sticking, curing , taxes and royalty all complete as per specification and direction of E/I. for construction of road cutting portion-

3.75

18606

4961.73

... More
Rising Main

-

-

-

... More
Manufacture, supply and Delivery of following Nominal dia UPVC column pipes including PVC socket (Coupler),

-

-

-

... More
50 mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:87.5 to 88.2mm wall Thickness End:9 .8 mm to 11.9mm, Barrel 7.3mm to 9 mm, Length: 3Mtrs. Delivery Pipe

30

4710

157

... More
Distribution

-

-

-

... More
Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties.

-

-

-

... More
50 mm HDPE Pipe-

100

11704

117.04

... More
32 mm HDPE Pipe-

250

11892

47.57

... More
20 mm MDPE Pipe-

250

6250

25

... More
Providing and fixing Gun Metal Gate valve with C I wheel of approved quality(screwed end).

-

-

-

... More
50 mm dia .

2

1552

776.07

... More
Providing and supplying High Density Polyethylene (HDPE ) fittings of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties.

1

1795

1795.4

... More
Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II.

-

-

-

... More
For Rising

-

-

-

... More
50 mm HDPE Pipe-

30

1110

37

... More
Distribution

-

-

-

... More
50 mm HDPE Pipe-

100

3700

37

... More
32 mm HDPE Pipe-

250

5750

23

... More
20 mm HDPE Pipe-

250

3000

12

... More
Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post.

25

3003

120.12

... More
Supplying all materials , labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge.

25

339

13.59

... More
Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I.

-

-

-

... More
(1) Elbow

-

-

-

... More
(a) 15 mm dia.

50

4039

80.78

... More
(2) Reducer Socket -

-

-

-

... More
(a) 20 x 15 mm dia.

25

2097

83.89

... More
(3) Nipple -

-

-

-

... More
(a) 15 mm dia.

50

3909

78.19

... More
(4) Plain Socket -

-

-

-

... More
(a) 15 mm dia.

50

3849

76.99

... More
Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram.

25

15582

623.29

... More
Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I.

-

-

-

... More
50 mm dia and weight not less than 1.5 Kg.

1

1552

1552.85

... More
Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socket all complete as per specification and direction of E/I.

-

-

-

... More
15 dia and weight not less than 400 Gm

25

4989

199.58

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

-

-

-

... More
Full way valve chamber

2

3424

1712.15

... More
Supplying materials , labours and equipment's for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surface all complete job, as per approved design, specification and direction of E/I.

25

35000

1400

... More
Providing brick masonry chamber of inner size 600 x 600 x 450 mm deep for bore well protection having 125 mm thick wall and 75 mm R.C.C cover including cement plaster of exposed surface, etc all complete job

1

2719

2719

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

87.13

7520

86.32

... More
Providing fitting & fixing 32 mm to 50 mm service HDPE saddle all complete job, as per approved design, specification and direction of E/I.

25

1350

54

... More
Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump

-

-

-

... More
Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.

-

-

-

... More
SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.

-

-

-

... More
i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)

-

-

-

... More
ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.

-

-

-

... More
iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.

-

-

-

... More
iv) The module mounting structure should be hot dip galvanized according to IS 4759.

-

-

-

... More
v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided

-

-

-

... More
vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)

-

-

-

... More
vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV

-

-

-

... More
viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.

-

-

-

... More
ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.

-

-

-

... More
x) The motor pump set should have a 5 years warranty.

-

-

-

... More
xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)

-

-

-

... More
xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.

-

-

-

... More
xiii) The system should be as per MNRE guide line & Eco-friendly with suitable arrangement to operate new pump manually.

-

-

-

... More
xiv) With third party inspection before dispatch.

-

-

-

... More
xv) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.

-

-

-

... More
The following details should be marked indelibly on the motor pump set

-

-

-

... More
a) Name of the Manufacturer or Distinctive Logo.

-

-

-

... More
b) Model Number.

-

-

-

... More
c) Serial Number.

-

-

-

... More
Solar submersible motor pump (SPV DC Type)

-

-

-

... More
i) 1 HP (DC Pump) with 900 WP minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 120 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)

1

119000

119000

... More
Carrying out recuperation/Yield Test for ascertaining the discharge of constructed well/ excavated profile as directed by the IEC. The test out by the drawing down water from the well/ profile below normal/subsoil water level up to full depth rise is recorded the normal water level/subsoil water level in the well / profile as well as strainer/level at pump as per design of W.S. scheme shall be recorded prior to the test including cost of all materials, over Load , Labours etc. complete as directed.

1

1865

1865

... More
Provision of solar night lamp.

1

1000

1000

... More
Annual Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 5 years

-

-

-

... More
O & M Cost for 1st year (Excluding Repair Charges)

1

9000

9000

... More
O & M Cost for 2nd year with Annual Repair Charges

1

10191

10191.01

... More
O & M cost for 3rd Year

1

10802

10802.47

... More
O & M cost for 4th Year

1

11450

11450.62

... More
O & M cost for 5th Year

1

12137

12137.66

... More
Provision of one no SIM card & its recharging cost for RMC

5

4000

800

... More
Tola - Manjhgaon (Litiya Chua)

-

-

-

... More
Construction of sanitary well 3.0 M internal diameter and 9.0 M deep with 1.0M Platform

-

-

-

... More
Supplying labour and equipment for digging well vide classfication of soil item-B including removing the spoils to a safe distance upto 50m from the edge of the well all complete as per specification and direction of E/I

132.64

21569

162.62

... More
Supplying labour and equipment for digging well vide classfication of soil item-C including removing the spoils to a safe distance upto 50m from the edge of the well all complete as per specification and direction of E/I.

-

-

-

... More
(a) E/W 03 to 04 metre depth below G.L

28.3

17780

628.38

... More
(b) E/W 04 to 05 metre depth below G.L item no. 3.1.67

24.65

17120

694.58

... More
(c) E/W 05 to 06 metre depth below G.L

21.25

16169

760.78

... More
(d) E/W 06 to 07 metre depth below G.L

18.11

14976

826.98

... More
(e) E/W 07 to 08 metre depth below G.L

15.22

13591

893.18

... More
(f) E/W 08 to 09 metre depth below G.L

12.58

12065

959.38

... More
Supplying materials and labour for providing R.C.C well curb (1:2:4) including centering and shuttering but excluding the cost of reinforcement all complete job as per specification and direction of E/I.

-

-

-

... More
R.C.C. Well Curb

1.01

5409

5355.59

... More
Providing rough dressed stone masonary in CM (1:6) in staining wall and in the parapet and well around in the platform including shuttering scaffolding if needed and providing adequate number of weep holes from bottem up to 4.5 M GL etc. all complete as per specification & direction of E/I.

-

-

-

... More
In Staining Wall

35.33

97455

2758.43

... More
In Parapet

2.42

6650

2744.71

... More
In Platform outer side wall

1.93

5297

2744.71

... More
Extra for each additional lift of 1m over the initial lift of 3m for masonry work.

-

-

-

... More
In Staining Wall (3-4m)

4.04

91

22.54

... More
In Staining Wall (4-5m)

4.04

182

45.08

... More
In Staining Wall (5-6m)

4.04

273

67.62

... More
In Staining Wall (6-7m)

4.04

364

90.16

... More
In Staining Wall (7-8m)

4.04

455

112.7

... More
In Staining Wall (8-9m)

4.04

546

135.24

... More
Supplying materials and labour fixing 20 mm dia M.S. bar steps in staining wall of 0.3 M interval and fixed with (1:2:4) P.C.C including scaffolding and curing etc. all complete job as per specification & direction of E/I.

16

3391

211.94

... More
Providing P.C.C M150 with nominal mix of (1:2:4) in foundation and plinth with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

-

-

-

... More
In Plateform

1.12

5159

4598.23

... More
Providing R.C.C M20 with nominal mix of (1:1.5:3) in beam of well with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

-

-

-

... More
BEAM

0.28

1471

5218

... More
Providing R.C.C M20 with nominal mix of (1:1.5:3) in roof slab of well with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

1.11

5798

5218

... More
Providing 12 mm thick cement plaster (1:4) with neat cement punning including scaffolding, curing with all leads & lifts of water, taxes & royalty ll complete as per specification & direction of E/I.

52.44

11982

228.49

... More
Providing 8 mm dia to 16 mm diaTor steel reinforcement (Fe 500 grade) of TATA or SAIL or Jindal Make as per approved design and drawing including all labour, materials, taxes etc but excluding cost of carriage of tor rod to work site including cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per specification & direction of E/I.

190

15365

80.87

... More
Supplying equipments and labour for desilting the well complete as per specification & direction of E/I.

1

1578

1578

... More
Supplying equipment and labour for back filling the excavated earth around staing well ll complete as per specification & direction of E/I.

152.73

14345

93.93

... More
Supplying equipment and labour for dewatering including supplying diesel pump set as per requirement and its fuel etc complete as per specification & direction of E/I. 2.0 HP x 8 Hour x 11 days =176

176

7612

43.25

... More
Carriage of Materials

-

-

-

... More
a) Stone Boulder lead- 11 Km (Pakka 1km Kutcha-10km)

63.93

35535

555.85

... More
b) Sand lead -25Km(Pakka 15 km Kutcha-10km)

29.87

19146

641

... More
c) Ston Chips lead - 30Km(Pakka 20 km Kutcha-10km)

3.1

2187

705.8

... More
d) Steel lead - 20 Km(Pakka 10km Kutcha-10km)

0.19

105

556

... More
e) Cement lead - 20 Km(Pakka 10km Kutcha-10km)

8.2

4559

556

... More
Construction RCC Foundation for Steel structure staging & Solar panel .

-

-

-

... More
Earth work in excavation in foundation trenches in ordinary soil and disposal of excavated earth as obtained to a distance up to 50.0m ,including all lifts, levelling ,ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design ,building specification and direction of E/I (vide classification of soil item -B)

4.37

731

167.33

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials ,labour ,royalty and taxes all complete as per building specification and direction of E/I(Mode of measurement compacted volume)

0.24

143

589.51

... More
Providing PCC M-150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I

0.24

1117

4598.23

... More
Providing RCC M-200 in nominal mix of (1:1.5:3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I.

-

-

-

... More
(a)Foundation for Steel structure staging

-

-

-

... More
Footing

0.81

4019

4961.73

... More
Vertical Pedestal

0.56

3375

5989.72

... More
Tie Beam

0.27

1624

5989.72

... More
Providing for steel reinforcement as per approved design and drawing excluding carriage of T.S. bar to work site cutting, bending with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I.

0.16

13503

82096.54

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

3.49

192

55.28

... More
Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.

-

-

-

... More
Cement + Rod (20 KM)

0.95

414

436

... More
Sand (20 KM)

1.03

418

406.24

... More
Stone Chips (20 KM)

1.58

641

406.24

... More
Galvanized tubular Steel structure staging for HDPE water storage Tank& Solar Panel

-

-

-

... More
Providing structural steel galvanised squre pipe section work in trusses, other similar trussed purlins and members with all bracing ,gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge ,including cutting fabricating ,hoisting , erecting and fixing in position , making riveted/bolted /welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & For Structure(PLUS) Providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns (Net wt. of components to be Galv) preferably TATA structural section etc complete.

1039.53

108464

104.34

... More
Information board for IEC

-

-

-

... More
Providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge including cutting fabricating hoisting erecting and fixing in position making reverted bolted welded connections one coat of anticorrosive paint and over it two coats of oil painting etc complete

27.2

2592

95.32

... More
Materials and labour for vinyl painting of matter given by department in different color

1.26

2520

2000

... More
Carriage of Steel Structure due to hilly & unapprocheble Habitation

1

11357

11357.73

... More
Installation of 2000 liters Capacity Water Storage Tank

-

-

-

... More
Providing and fixing HDPE container Syntex or alike one piecemolded water tank made out of low density polythyler andbuilt corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity 2000.00 litres Capacity Water storage Tank

2000

15500

7.75

... More
Transportation Charge

1

1000

1000

... More
Lifting of 2000 Litrs Capacity Tank up to 4.50m height with lifting tools with rope and labour

1

500

500

... More
Making hole in Tank

4

100

25

... More
Making long screw in G.I. pipe including supplying and fitting jam nuts and extra socket etc.

4

634

158.59

... More
Rising and Distribution Network with House Connection up to 10 Nos. including Platform & Stand post

-

-

-

... More
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.

97

14578

150.29

... More
Dismantling plain cement concrete work including stacking serviceable materials in countable stacks within 15 M lead and disposal of unserviceable materials with all leads all complete

1.88

1797

955.89

... More
Providing PCC M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, sticking, curing , taxes and royalty all complete as per specification and direction of E/I. for construction of road cutting portion-

1.88

9328

4961.73

... More
Rising Main

-

-

-

... More
Manufacture, supply and Delivery of following Nominal dia UPVC column pipes including PVC socket (Coupler),

-

-

-

... More
50 mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:87.5 to 88.2mm wall Thickness End:9 .8 mm to 11.9mm, Barrel 7.3mm to 9 mm, Length: 3Mtrs. Delivery Pipe

25

3925

157

... More
Distribution

-

-

-

... More
Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10

-

-

-

... More
50 mm HDPE Pipe-

75

8778

117.04

... More
32 mm HDPE Pipe-

300

14271

47.57

... More
20 mm MDPE Pipe-

200

5000

25

... More
Providing and fixing Gun Metal Gate valve with C I wheel of approved quality(screwed end).

-

-

-

... More
50 mm dia .

1

776

776.07

... More
Providing and supplying High Density Polyethylene (HDPE ) fittings of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10

1

1377

1377.8

... More
Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II.

-

-

-

... More
For Rising

-

-

-

... More
50 mm HDPE Pipe-

25

925

37

... More
Distribution

-

-

-

... More
50 mm HDPE Pipe-

75

2775

37

... More
32 mm HDPE Pipe-

300

6900

23

... More
20 mm MDPE Pipe-

200

2400

12

... More
Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post.

15

1801

120.12

... More
Supplying all materials , labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge.

15

203

13.59

... More
Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I.

-

-

-

... More
(1) Elbow

-

-

-

... More
(a) 15 mm dia.

30

2423

80.78

... More
(2) Reducer Socket -

-

-

-

... More
(a) 20 x 15 mm dia.

15

1258

83.89

... More
(3) Nipple -

-

-

-

... More
(a) 15 mm dia.

30

2345

78.19

... More
(4) Plain Socket -

-

-

-

... More
(a) 15 mm dia.

30

2309

76.99

... More
Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram.

15

9349

623.29

... More
Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I.

-

-

-

... More
50 mm dia and weight not less than 1.5 Kg.

2

3105

1552.85

... More
Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socket all complete as per specification and direction of E/I.

-

-

-

... More
15 dia and weight not less than 400 Gm

15

2993

199.58

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

-

-

-

... More
Full way valve chamber

1

1712

1712.15

... More
Supplying materials , labours and equipment's for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surface all complete job, as per approved design, specification and direction of E/I.

15

21000

1400

... More
Providing brick masonry chamber of inner size 600 x 600 x 450 mm deep for bore well protection having 125 mm thick wall and 75 mm R.C.C cover including cement plaster of exposed surface, etc all complete job

1

2719

2719

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

82.45

7744

93.93

... More
Providing fitting & fixing 32 mm to 50 mm service HDPE saddle all complete job, as per approved design, specification and direction of E/I.

15

810

54

... More
Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump

-

-

-

... More
Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.

-

-

-

... More
SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.

-

-

-

... More
i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)

-

-

-

... More
ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.

-

-

-

... More
iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.

-

-

-

... More
iv) The module mounting structure should be hot dip galvanized according to IS 4759.

-

-

-

... More
v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided

-

-

-

... More
vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)

-

-

-

... More
vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV

-

-

-

... More
viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.

-

-

-

... More
ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.

-

-

-

... More
x) The motor pump set should have a 5 years warranty.

-

-

-

... More
xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)

-

-

-

... More
xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.

-

-

-

... More
xiii) The system should be as per MNRE guide line & Ecofriendly with suitable arrangement to operate new pump manually.

-

-

-

... More
xiv) With third party inspection before dispatch.

-

-

-

... More
xv) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.

-

-

-

... More
The following details should be marked indelibly on the motor pump set

-

-

-

... More
a) Name of the Manufacturer or Distinctive Logo.

-

-

-

... More
b) Model Number.

-

-

-

... More
c) Serial Number.

-

-

-

... More
Solar submersible motor pump (SPV DC Type)

-

-

-

... More
i) 2 HP (DC Pump) with 1800 wp minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 100 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)

1

170820

170820

... More
Provision of solar night lamp.

1

1000

1000

... More
Annual Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 5 years

-

-

-

... More
O & M Cost for 1st year (Excluding Repair Charges)

1

9000

9000

... More
O & M Cost for 2nd year with Annual Repair Charges

1

9960

9960.19

... More
O & M cost for 3rd Year

1

10557

10557.8

... More
O & M cost for 4th Year

1

11191

11191.27

... More
O & M cost for 5th Year

1

11862

11862.75

... More
Provision of one no SIM card & its recharging cost for RMC

5

4000

800

... More
Tola - Manjhgaon (Luchutpat)

-

-

-

... More
Construction of sanitary well 3.0 M internal diameter and 9.0 M deep with 1.0M Platform

-

-

-

... More
Supplying labour and equipment for digging well vide classfication of soil item-B including removing the spoils to a safe distance upto 50m from the edge of the well all complete as per specification and direction of E/I

132.64

21569

162.62

... More
Supplying labour and equipment for digging well vide classfication of soil item-C including removing the spoils to a safe distance upto 50m from the edge of the well all complete as per specification and direction of E/I.

-

-

-

... More
(a) E/W 03 to 04 metre depth below G.L

28.3

17780

628.38

... More
(b) E/W 04 to 05 metre depth below G.L item no. 3.1.67

24.65

17120

694.58

... More
(c) E/W 05 to 06 metre depth below G.L

21.25

16169

760.78

... More
(d) E/W 06 to 07 metre depth below G.L

18.11

14976

826.98

... More
(e) E/W 07 to 08 metre depth below G.L

15.22

13591

893.18

... More
(f) E/W 08 to 09 metre depth below G.L

12.58

12065

959.38

... More
Supplying materials and labour for providing R.C.C well curb (1:2:4) including centering and shuttering but excluding the cost of reinforcement all complete job as per specification and direction of E/I.

-

-

-

... More
R.C.C. Well Curb

1.01

5409

5355.59

... More
Providing rough dressed stone masonary in CM (1:6) in staining wall and in the parapet and well around in the platform including shuttering scaffolding if needed and providing adequate number of weep holes from bottem up to 4.5 M GL etc. all complete as per specification & direction of E/I.

-

-

-

... More
In Staining Wall

35.33

97455

2758.43

... More
In Parapet

2.42

6650

2744.71

... More
In Platform outer side wall

1.93

5297

2744.71

... More
Extra for each additional lift of 1m over the initial lift of 3m for masonry work.

-

-

-

... More
In Staining Wall (3-4m)

4.04

91

22.54

... More
In Staining Wall (4-5m)

4.04

182

45.08

... More
In Staining Wall (5-6m)

4.04

273

67.62

... More
In Staining Wall (6-7m)

4.04

364

90.16

... More
In Staining Wall (7-8m)

4.04

455

112.7

... More
In Staining Wall (8-9m)

4.04

546

135.24

... More
Supplying materials and labour fixing 20 mm dia M.S. bar steps in staining wall of 0.3 M interval and fixed with (1:2:4) P.C.C including scaffolding and curing etc. all complete job as per specification & direction of E/I.

16

3391

211.94

... More
Providing P.C.C M150 with nominal mix of (1:2:4) in foundation and plinth with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

-

-

-

... More
In Plateform

1.12

5159

4598.23

... More
Providing R.C.C M20 with nominal mix of (1:1.5:3) in beam of well with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

-

-

-

... More
BEAM

0.28

1471

5218

... More
Providing R.C.C M20 with nominal mix of (1:1.5:3) in roof slab of well with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

1.11

5798

5218

... More
Providing 12 mm thick cement plaster (1:4) with neat cement punning including scaffolding, curing with all leads & lifts of water, taxes & royalty ll complete as per specification & direction of E/I.

52.44

11982

228.49

... More
Providing 8 mm dia to 16 mm diaTor steel reinforcement (Fe 500 grade) of TATA or SAIL or Jindal Make as per approved design and drawing including all labour, materials, taxes etc but excluding cost of carriage of tor rod to work site including cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per specification & direction of E/I.

190

15365

80.87

... More
Supplying equipments and labour for desilting the well complete as per specification & direction of E/I.

1

1578

1578

... More
Supplying equipment and labour for back filling the excavated earth around staing well ll complete as per specification & direction of E/I.

152.73

14345

93.93

... More
Supplying equipment and labour for dewatering including supplying diesel pump set as per requirement and its fuel etc complete as per specification & direction of E/I. 2.0 HP x 8 Hour x 11 days =176

176

7612

43.25

... More
Carriage of Materials

-

-

-

... More
a) Stone Boulder lead- 11 Km (Pakka 1km Kutcha-10km)

63.93

35535

555.85

... More
b) Sand lead -25Km(Pakka 15 km Kutcha-10km)

29.87

19146

641

... More
c) Ston Chips lead - 30Km(Pakka 20 km Kutcha-10km)

3.1

2187

705.8

... More
d) Steel lead - 20 Km(Pakka 10km Kutcha-10km)

0.19

105

556

... More
e) Cement lead - 20 Km(Pakka 10km Kutcha-10km)

8.2

4559

556

... More
Construction RCC Foundation for Steel structure staging & Solar panel .

-

-

-

... More
Earth work in excavation in foundation trenches in ordinary soil and disposal of excavated earth as obtained to a distance up to 50.0m ,including all lifts, levelling ,ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design ,building specification and direction of E/I (vide classification of soil item -B)

4.37

731

167.33

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials ,labour ,royalty and taxes all complete as per building specification and direction of E/I(Mode of measurement compacted volume)

0.24

143

589.51

... More
Providing PCC M-150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I

0.24

1117

4598.23

... More
Providing RCC M-200 in nominal mix of (1:1.5:3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I.

-

-

-

... More
(a)Foundation for Steel structure staging

-

-

-

... More
Footing

0.81

4019

4961.73

... More
Vertical Pedestal

0.56

3375

5989.72

... More
Tie Beam

0.27

1624

5989.72

... More
Providing for steel reinforcement as per approved design and drawing excluding carriage of T.S. bar to work site cutting, bending with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I.

0.16

13503

82096.54

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

3.49

192

55.28

... More
Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.

-

-

-

... More
Cement + Rod (20 KM)

0.95

414

436

... More
Sand (20 KM)

1.03

418

406.24

... More
Stone Chips (20 KM)

1.58

641

406.24

... More
Galvanized tubular Steel structure staging for HDPE water storage Tank& Solar Panel

-

-

-

... More
Providing structural steel galvanised squre pipe section work in trusses, other similar trussed purlins and members with all bracing ,gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge ,including cutting fabricating ,hoisting , erecting and fixing in position , making riveted/bolted /welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & For Structure(PLUS) Providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns (Net wt. of components to be Galv) preferably TATA structural section etc complete.

1039.53

108464

104.34

... More
Information board for IEC

-

-

-

... More
Providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge including cutting fabricating hoisting erecting and fixing in position making reverted bolted welded connections one coat of anticorrosive paint and over it two coats of oil painting etc complete

27.2

2592

95.32

... More
Materials and labour for vinyl painting of matter given by department in different color

1.26

2520

2000

... More
Carriage of Steel Structure due to hilly & unapprocheble Habitation

1

11357

11357.73

... More
Installation of 2000 liters Capacity Water Storage Tank

-

-

-

... More
Providing and fixing HDPE container Syntex or alike one piecemolded water tank made out of low density polythyler andbuilt corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity 2000.00 litres Capacity Water storage Tank

2000

15500

7.75

... More
Transportation Charge

1

1000

1000

... More
Lifting of 2000 Litrs Capacity Tank up to 4.50m height with lifting tools with rope and labour

1

500

500

... More
Making hole in Tank

4

100

25

... More
Making long screw in G.I. pipe including supplying and fitting jam nuts and extra socket etc.

4

634

158.59

... More
Rising and Distribution Network with House Connection up to 10 Nos. including Platform & Stand post

-

-

-

... More
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.

97

14578

150.29

... More
Dismantling plain cement concrete work including stacking serviceable materials in countable stacks within 15 M lead and disposal of unserviceable materials with all leads all complete

2.25

2150

955.89

... More
Providing PCC M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, sticking, curing , taxes and royalty all complete as per specification and direction of E/I. for construction of road cutting portion-

2.25

11163

4961.73

... More
Rising Main

-

-

-

... More
Manufacture, supply and Delivery of following Nominal dia UPVC column pipes including PVC socket (Coupler),

-

-

-

... More
50 mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:87.5 to 88.2mm wall Thickness End:9 .8 mm to 11.9mm, Barrel 7.3mm to 9 mm, Length: 3Mtrs. Delivery Pipe

25

3925

157

... More
Distribution

-

-

-

... More
Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10

-

-

-

... More
50 mm HDPE Pipe-

75

8778

117.04

... More
32 mm HDPE Pipe-

300

14271

47.57

... More
20 mm MDPE Pipe-

200

5000

25

... More
Providing and fixing Gun Metal Gate valve with C I wheel of approved quality(screwed end).

-

-

-

... More
50 mm dia .

1

776

776.07

... More
Providing and supplying High Density Polyethylene (HDPE ) fittings of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10

1

1377

1377.8

... More
Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II.

-

-

-

... More
For Rising

-

-

-

... More
50 mm HDPE Pipe-

25

925

37

... More
Distribution

-

-

-

... More
50 mm HDPE Pipe-

75

2775

37

... More
32 mm HDPE Pipe-

300

6900

23

... More
20 mm MDPE Pipe-

200

2400

12

... More
Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post.

14

1681

120.12

... More
Supplying all materials , labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge.

14

190

13.59

... More
Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I.

-

-

-

... More
(1) Elbow

-

-

-

... More
(a) 15 mm dia.

28

2261

80.78

... More
(2) Reducer Socket -

-

-

-

... More
(a) 20 x 15 mm dia.

14

1174

83.89

... More
(3) Nipple -

-

-

-

... More
(a) 15 mm dia.

28

2189

78.19

... More
(4) Plain Socket -

-

-

-

... More
(a) 15 mm dia.

28

2155

76.99

... More
Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram.

14

8726

623.29

... More
Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I.

-

-

-

... More
50 mm dia and weight not less than 1.5 Kg.

2

3105

1552.85

... More
Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socket all complete as per specification and direction of E/I.

-

-

-

... More
15 dia and weight not less than 400 Gm

14

2794

199.58

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

-

-

-

... More
Full way valve chamber

1

1712

1712.15

... More
Supplying materials , labours and equipment's for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surface all complete job, as per approved design, specification and direction of E/I.

14

19600

1400

... More
Providing brick masonry chamber of inner size 600 x 600 x 450 mm deep for bore well protection having 125 mm thick wall and 75 mm R.C.C cover including cement plaster of exposed surface, etc all complete job

1

2719

2719

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

82.45

7744

93.93

... More
Providing fitting & fixing 32 mm to 50 mm service HDPE saddle all complete job, as per approved design, specification and direction of E/I.

14

756

54

... More
Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump

-

-

-

... More
Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.

-

-

-

... More
SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.

-

-

-

... More
i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)

-

-

-

... More
ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.

-

-

-

... More
iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.

-

-

-

... More
iv) The module mounting structure should be hot dip galvanized according to IS 4759.

-

-

-

... More
v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided

-

-

-

... More
vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)

-

-

-

... More
vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV

-

-

-

... More
viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.

-

-

-

... More
ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.

-

-

-

... More
x) The motor pump set should have a 5 years warranty.

-

-

-

... More
xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)

-

-

-

... More
xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.

-

-

-

... More
xiii) The system should be as per MNRE guide line & Ecofriendly with suitable arrangement to operate new pump manually.

-

-

-

... More
xiv) With third party inspection before dispatch.

-

-

-

... More
xv) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.

-

-

-

... More
The following details should be marked indelibly on the motor pump set

-

-

-

... More
a) Name of the Manufacturer or Distinctive Logo.

-

-

-

... More
b) Model Number.

-

-

-

... More
c) Serial Number.

-

-

-

... More
Solar submersible motor pump (SPV DC Type)

-

-

-

... More
i) 2 HP (DC Pump) with 1800 wp minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 100 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)

1

170820

170820

... More
Provision of solar night lamp.

1

1000

1000

... More
Annual Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 5 years

-

-

-

... More
O & M Cost for 1st year (Excluding Repair Charges)

1

9000

9000

... More
O & M Cost for 2nd year with Annual Repair Charges

1

9958

9958.25

... More
O & M cost for 3rd Year

1

10555

10555.74

... More
O & M cost for 4th Year

1

11189

11189.09

... More
O & M cost for 5th Year

1

11860

11860.43

... More
Provision of one no SIM card & its recharging cost for RMC

5

4000

800

... More
Tola - Manjhgaon (Bagdipani)

-

-

-

... More
Construction of sanitary well 3.0 M internal diameter and 9.0 M deep with 1.0M Platform

-

-

-

... More
Supplying labour and equipment for digging well vide classfication of soil item-B including removing the spoils to a safe distance upto 50m from the edge of the well all complete as per specification and direction of E/I

132.64

21569

162.62

... More
Supplying labour and equipment for digging well vide classfication of soil item-C including removing the spoils to a safe distance upto 50m from the edge of the well all complete as per specification and direction of E/I.

-

-

-

... More
(a) E/W 03 to 04 metre depth below G.L

28.3

17780

628.38

... More
(b) E/W 04 to 05 metre depth below G.L item no. 3.1.67

24.65

17120

694.58

... More
(c) E/W 05 to 06 metre depth below G.L

21.25

16169

760.78

... More
(d) E/W 06 to 07 metre depth below G.L

18.11

14976

826.98

... More
(e) E/W 07 to 08 metre depth below G.L

15.22

13591

893.18

... More
(f) E/W 08 to 09 metre depth below G.L

12.58

12065

959.38

... More
Supplying materials and labour for providing R.C.C well curb (1:2:4) including centering and shuttering but excluding the cost of reinforcement all complete job as per specification and direction of E/I.

-

-

-

... More
R.C.C. Well Curb

1.01

5409

5355.59

... More
Providing rough dressed stone masonary in CM (1:6) in staining wall and in the parapet and well around in the platform including shuttering scaffolding if needed and providing adequate number of weep holes from bottem up to 4.5 M GL etc. all complete as per specification & direction of E/I.

-

-

-

... More
In Staining Wall

35.33

97455

2758.43

... More
In Parapet

2.42

6650

2744.71

... More
In Platform outer side wall

1.93

5297

2744.71

... More
Extra for each additional lift of 1m over the initial lift of 3m for masonry work.

-

-

-

... More
In Staining Wall (3-4m)

4.04

91

22.54

... More
In Staining Wall (4-5m)

4.04

182

45.08

... More
In Staining Wall (5-6m)

4.04

273

67.62

... More
In Staining Wall (6-7m)

4.04

364

90.16

... More
In Staining Wall (7-8m)

4.04

455

112.7

... More
In Staining Wall (8-9m)

4.04

546

135.24

... More
Supplying materials and labour fixing 20 mm dia M.S. bar steps in staining wall of 0.3 M interval and fixed with (1:2:4) P.C.C including scaffolding and curing etc. all complete job as per specification & direction of E/I.

16

3391

211.94

... More
Providing P.C.C M150 with nominal mix of (1:2:4) in foundation and plinth with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

-

-

-

... More
In Plateform

1.12

5159

4598.23

... More
Providing R.C.C M20 with nominal mix of (1:1.5:3) in beam of well with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

-

-

-

... More
BEAM

0.28

1471

5218

... More
Providing R.C.C M20 with nominal mix of (1:1.5:3) in roof slab of well with approved quality of stone chips 20 mm to 6 mm size graded & clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty but excluding the cost of M.S reinforcemet all complete as per specification & direction of E/I.

1.11

5798

5218

... More
Providing 12 mm thick cement plaster (1:4) with neat cement punning including scaffolding, curing with all leads & lifts of water, taxes & royalty ll complete as per specification & direction of E/I.

52.44

11982

228.49

... More
Providing 8 mm dia to 16 mm diaTor steel reinforcement (Fe 500 grade) of TATA or SAIL or Jindal Make as per approved design and drawing including all labour, materials, taxes etc but excluding cost of carriage of tor rod to work site including cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per specification & direction of E/I.

190

15365

80.87

... More
Supplying equipments and labour for desilting the well complete as per specification & direction of E/I.

1

1578

1578

... More
Supplying equipment and labour for back filling the excavated earth around staing well ll complete as per specification & direction of E/I.

152.73

14345

93.93

... More
Supplying equipment and labour for dewatering including supplying diesel pump set as per requirement and its fuel etc complete as per specification & direction of E/I. 2.0 HP x 8 Hour x 11 days =176

176

7612

43.25

... More
Carriage of Materials

-

-

-

... More
a) Stone Boulder lead- 11 Km (Pakka 1km Kutcha-10km)

63.93

35535

555.85

... More
b) Sand lead -25Km(Pakka 15 km Kutcha-10km)

29.87

19146

641

... More
c) Ston Chips lead - 30Km(Pakka 20 km Kutcha-10km)

3.1

2187

705.8

... More
d) Steel lead - 20 Km(Pakka 10km Kutcha-10km)

0.19

105

556

... More
e) Cement lead - 20 Km(Pakka 10km Kutcha-10km)

8.2

4559

556

... More
Construction RCC Foundation for Steel structure staging & Solar panel .

-

-

-

... More
Earth work in excavation in foundation trenches in ordinary soil and disposal of excavated earth as obtained to a distance up to 50.0m ,including all lifts, levelling ,ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design ,building specification and direction of E/I (vide classification of soil item -B)

4.37

731

167.33

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials ,labour ,royalty and taxes all complete as per building specification and direction of E/I(Mode of measurement compacted volume)

0.24

143

589.51

... More
Providing PCC M-150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I

0.24

1117

4598.23

... More
Providing RCC M-200 in nominal mix of (1:1.5:3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M.2.5to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating striking curing and royalty all complete as per building specification and direction of E/I.

-

-

-

... More
(a)Foundation for Steel structure staging

-

-

-

... More
Footing

0.81

4019

4961.73

... More
Vertical Pedestal

0.56

3375

5989.72

... More
Tie Beam

0.27

1624

5989.72

... More
Providing for steel reinforcement as per approved design and drawing excluding carriage of T.S. bar to work site cutting, bending with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I.

0.16

13503

82096.54

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

3.49

192

55.28

... More
Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.

-

-

-

... More
Cement + Rod (20 KM)

0.95

414

436

... More
Sand (20 KM)

1.03

418

406.24

... More
Stone Chips (20 KM)

1.58

641

406.24

... More
Galvanized tubular Steel structure staging for HDPE water storage Tank& Solar Panel

-

-

-

... More
Providing structural steel galvanised squre pipe section work in trusses, other similar trussed purlins and members with all bracing ,gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge ,including cutting fabricating ,hoisting , erecting and fixing in position , making riveted/bolted /welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & For Structure(PLUS) Providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns (Net wt. of components to be Galv) preferably TATA structural section etc complete.

1039.53

108464

104.34

... More
Information board for IEC

-

-

-

... More
Providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge including cutting fabricating hoisting erecting and fixing in position making reverted bolted welded connections one coat of anticorrosive paint and over it two coats of oil painting etc complete

27.2

2592

95.32

... More
Materials and labour for vinyl painting of matter given by department in different color

1.26

2520

2000

... More
Carriage of Steel Structure due to hilly & unapprocheble Habitation

1

11357

11357.73

... More
Installation of 2000 liters Capacity Water Storage Tank

-

-

-

... More
Providing and fixing HDPE container Syntex or alike one piecemolded water tank made out of low density polythyler andbuilt corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity 2000.00 litres Capacity Water storage Tank

2000

15500

7.75

... More
Transportation Charge

1

1000

1000

... More
Lifting of 2000 Litrs Capacity Tank up to 4.50m height with lifting tools with rope and labour

1

500

500

... More
Making hole in Tank

4

100

25

... More
Making long screw in G.I. pipe including supplying and fitting jam nuts and extra socket etc.

4

634

158.59

... More
Rising and Distribution Network with House Connection up to 10 Nos. including Platform & Stand post

-

-

-

... More
Earth work in excavation in foundation trenches in hard soil (Vide Classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I.

97

14578

150.29

... More
Dismantling plain cement concrete work including stacking serviceable materials in countable stacks within 15 M lead and disposal of unserviceable materials with all leads all complete

1.88

1797

955.89

... More
Providing PCC M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, sticking, curing , taxes and royalty all complete as per specification and direction of E/I. for construction of road cutting portion-

1.88

9328

4961.73

... More
Rising Main

-

-

-

... More
Manufacture, supply and Delivery of following Nominal dia UPVC column pipes including PVC socket (Coupler),

-

-

-

... More
50 mm dia -Density of pipe 1.38 to 1.43 Gm per Cm3 OD:87.5 to 88.2mm wall Thickness End:9 .8 mm to 11.9mm, Barrel 7.3mm to 9 mm, Length: 3Mtrs. Delivery Pipe

25

3925

157

... More
Distribution

-

-

-

... More
Providing and supplying High Density Polyethylene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10

-

-

-

... More
50 mm HDPE Pipe-

75

8778

117.04

... More
32 mm HDPE Pipe-

300

14271

47.57

... More
20 mm MDPE Pipe-

200

5000

25

... More
Providing and fixing Gun Metal Gate valve with C I wheel of approved quality(screwed end).

-

-

-

... More
50 mm dia .

1

776

776.07

... More
Providing and supplying High Density Polyethylene (HDPE ) fittings of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 suitable for water supply which is available in all standard conforming to ISI -- 4984/14151/12786/13488,ISO 4427 , DIN-8074 materials rates are Ex-factory excluding transportation, taxes and duties. PE-80 , PN- 10

1

1377

1377.8

... More
Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electro fusion and butt fusion jointing procedure as per relevant IS Code complete with all materials for jointing procedure like Electro fusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II.

-

-

-

... More
For Rising

-

-

-

... More
50 mm HDPE Pipe-

25

925

37

... More
Distribution

-

-

-

... More
50 mm HDPE Pipe-

75

2775

37

... More
32 mm HDPE Pipe-

300

6900

23

... More
20 mm MDPE Pipe-

200

2400

12

... More
Providing 15 mm dia. G.I. pipe Tata or equivalent make as per IS 1239 (Part 1/2004) ISI Mark /medium quality in Stand Post.

13

1561

120.12

... More
Supplying all materials , labour and tools for fixing 15 mm dia G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketed joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge.

13

176

13.59

... More
Supplying and fixing G.I. fittings of approved make all complete as per specification and direction of E/I.

-

-

-

... More
(1) Elbow

-

-

-

... More
(a) 15 mm dia.

26

2100

80.78

... More
(2) Reducer Socket -

-

-

-

... More
(a) 20 x 15 mm dia.

13

1090

83.89

... More
(3) Nipple -

-

-

-

... More
(a) 15 mm dia.

26

2032

78.19

... More
(4) Plain Socket -

-

-

-

... More
(a) 15 mm dia.

26

2001

76.99

... More
Supplying and fixing G.M. ferrule of approved make in existing C.I./D.I. main Including drilling and taping C.I./D.I. main all complete as per specification and direction of E/I. 3 mm, 6 mm 10 mm dm ferrule weight not less than 425 gram.

13

8102

623.29

... More
Providing and fixing Gun Metal full way valve of approved quality, all complete, as per specification and direction of E/I.

-

-

-

... More
50 mm dia and weight not less than 1.5 Kg.

2

3105

1552.85

... More
Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socket all complete as per specification and direction of E/I.

-

-

-

... More
15 dia and weight not less than 400 Gm

13

2594

199.58

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.

-

-

-

... More
Full way valve chamber

1

1712

1712.15

... More
Supplying materials , labours and equipment's for construction of 0.90M x 0.90 M size P.C.C. (1:2:4) Rectangular Platform with stand post in house including 12 mm thick cement plaster in C.M. (1:4) with neat cement punning over exposed surface all complete job, as per approved design, specification and direction of E/I.

13

18200

1400

... More
Providing brick masonry chamber of inner size 600 x 600 x 450 mm deep for bore well protection having 125 mm thick wall and 75 mm R.C.C cover including cement plaster of exposed surface, etc all complete job

1

2719

2719

... More
Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-Charge.

82.45

7744

93.93

... More
Providing fitting & fixing 32 mm to 50 mm service HDPE saddle all complete job, as per approved design, specification and direction of E/I.

13

702

54

... More
Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump

-

-

-

... More
Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.

-

-

-

... More
SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.

-

-

-

... More
i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)

-

-

-

... More
ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.

-

-

-

... More
iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.

-

-

-

... More
iv) The module mounting structure should be hot dip galvanized according to IS 4759.

-

-

-

... More
v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided

-

-

-

... More
vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)

-

-

-

... More
vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV

-

-

-

... More
viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.

-

-

-

... More
ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.

-

-

-

... More
x) The motor pump set should have a 5 years warranty.

-

-

-

... More
xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)

-

-

-

... More
xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.

-

-

-

... More
xiii) The system should be as per MNRE guide line & Ecofriendly with suitable arrangement to operate new pump manually.

-

-

-

... More
xiv) With third party inspection before dispatch.

-

-

-

... More
xv) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.

-

-

-

... More
The following details should be marked indelibly on the motor pump set

-

-

-

... More
a) Name of the Manufacturer or Distinctive Logo.

-

-

-

... More
b) Model Number.

-

-

-

... More
c) Serial Number.

-

-

-

... More
Solar submersible motor pump (SPV DC Type)

-

-

-

... More
i) 2 HP (DC Pump) with 1800 wp minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 100 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)

1

170820

170820

... More
Provision of solar night lamp.

1

1000

1000

... More
Annual Operation & Maintenance cost based on Existing D/T Well with solar motor pump for 5 years

-

-

-

... More
O & M Cost for 1st year (Excluding Repair Charges)

1

9000

9000

... More
O & M Cost for 2nd year with Annual Repair Charges

1

9945

9945.36

... More
O & M cost for 3rd Year

1

10542

10542.08

... More
O & M cost for 4th Year

1

11174

11174.61

... More
O & M cost for 5th Year

1

11845

11845.09

... More
Provision of one no SIM card & its recharging cost for RMC

5

4000

800

... More
Add 18% GST.

1

1295544

1295544.21

... More
Add 1% Labour Cess

1

84930

84930.12



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.