Drinking Water And Sanitation Department Tender

... More
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Drinking Water And Sanitation Department - DWSD Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date6 Mar 2025
Closing Soon12 Mar 2025
Tender Amount₹ 64,20,659 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe etc. all complete job. (DWSD Item 120)

54

1760

95040

... More
Supplying all materials, labour, tools & equipments for fitting & fixing 200mm dia MS cap over casing pipe complete job. (DWSD Item 120 B)

3

242

726

... More
Carrying out recuperation/Yield Test for ascertaining the discharge of constructed well/ excavated profile as directed by the IEC. The test out by the drawing down water from the well/ profile below normal/subsoil water level up to full depth rise is recorded the normal water level/subsoil water level in the well / profile as well as strainer/level at pump as per design of W.S. scheme shall be recorded prior to the test including cost of all materials, over Load , Labours etc. complete as directed.

3

1865

5595

... More
Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump

-

-

-

... More
Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories.

-

-

-

... More
SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak.

-

-

-

... More
i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0)

-

-

-

... More
ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required.

-

-

-

... More
iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h.

-

-

-

... More
iv) The module mounting structure should be hot dip galvanized according to IS 4759.

-

-

-

... More
v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided

-

-

-

... More
vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification)

-

-

-

... More
vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV

-

-

-

... More
viii) The suction/delivery pipe shall be UPVC / H.D.P.E. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg/Sq cm- PE 100 grade for pump up to 3HP & 10 Kg/Sq cm- PE 100 grade for 5 HP.

-

-

-

... More
ix) All cable used shall be as per IS 694. Suitable size of cable shall be used in sufficient length for inter connection between the SPV array to SPV controller and SPV controller to solar power pump. Provision of cable shall be as per IS 14536.

-

-

-

... More
x) The motor pump set should have a 5 years warranty.

-

-

-

... More
xi) Control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. (As per MNRE Specification)

-

-

-

... More
xii) The SPV controller must have IP-65 protection or must be housed in cabinet having at least IP-65 protection.

-

-

-

... More
xiii) The system should be as per MNRE guide line & Eco-friendly with suitable arrangement to operate new pump manually.

-

-

-

... More
xiv) With third party inspection before dispatch.

-

-

-

... More
xv) Provision for web based remote monitoring of the pumps to be installed must be made through the inbuilt controllers . It should be possible to ascertain the daily water output, the power generated by PV Array ,the Up and down time of the pump during the year, number of days the pump was unused or under breakdown repairs.

-

-

-

... More
The following details should be marked indelibly on the motor pump set

-

-

-

... More
a) Name of the Manufacturer or Distinctive Logo.

-

-

-

... More
b) Model Number.

-

-

-

... More
c) Serial Number.

-

-

-

... More
Solar submersible motor pump (SPV DC Type)

-

-

-

... More
i) 2 HP (DC Pump) with 1800 wp minimum watt P.V. Panel as MNRE pump head Max Shut-off head up to 100 mtrs. For higher or lower head or in between various modules output could be decided on prorates basis. (As per latest guide line of MNRE)

17

170820

2903940

... More
Provision of solar night lamp.

17

1000

17000

... More
Information Board

-

-

-

... More
information board Providing structural steel work in trusses other similar trussed purline and members with bracing gusset plates etc as per detailed design and drawing or as directed and fixing in position making reverted boiled weided connections one coat of anticorrosive paint over it two coals of oil painting etc.

-

-

-

... More
(1)Square Tube 25mmx25mmx2mm thick

-

-

-

... More
2Nosx1.50m=3.00mx1.96kg/m=5.94 kg

-

-

-

... More
(2)Square Tube 25mmx25mmx2mm thick

-

-

-

... More
3Nosx1.20m=3.60mx1.98kg/m=7.13kg

-

-

-

... More
(3) M.S Sheet 1mm thick 1nosx1.50x1.20m=180m2

-

-

-

... More
1.80m2x7.85kg/m2 =14.13kg

-

-

-

... More
Total=27.20 kg

462.4

95

44075.97

... More
Materials and labour for vinyl painting of matter given by department in different color (Asper market Rate)

-

-

-

... More
1nosx2.10mx0.60m=1.26m2

17

2000

34000

... More
Rising & Delivery Pipe line Arrangement

-

-

-

... More
Earth work in excavation (As per I.S. 3114) 1965 for laying of different sizes of pipe so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification & direction E/I. Soil Item “B”

45.9

150

6898.31

... More
Earth work in back filling in the trenches after laying different sizes of pipe with earth removed during excavation lead & left as per specification & direction E/I. 85% Of E/W Excavation

39.02

93

3664.68

... More
Laying of G.I. pipes of approved make in trenches with red lead and yarn with socket and screw joints and cutting pipes to sizes and threading ends where necessary etc. all complete as per specification and direction or Engineer-in-charge.

255

21

5523.3

... More
Supplying labours and tools for fixing G.I pipe with red lead and yarm of folloing nominal bore with screwed socketted joints on wall, celling and floor including supplying and fitting of wall hooks or pipe clamps wooden pluge, cutting to size and threading ends if required etc all complete as per specification and direction E/I.

-

-

-

... More
32 mm dia 06.00 m

85

79

6729.45

... More
Cost of GI Pipe (Tata or equivalent ) Medium Quality as per IS: 1239

-

-

-

... More
32 mm dia 06.00 m

85

244

20782.5

... More
25 mm dia 06.00 m

85

205

17442

... More
Supplying and fixing GI fittings approved make (Conforming to I.S 1879) all complete as per specification and direction of E/I

-

-

-

... More
(i) Elbow

-

-

-

... More
32 mm dia 04 Nos

68

175

11958.48

... More
(ii) Tee (Plain)

-

-

-

... More
20 mm dia -- 06 nos

102

107

10944.6

... More
(iii) Nipple

-

-

-

... More
20 mm dia --- 05 nos

85

93

7972.15

... More
(iv) Union Socket

-

-

-

... More
32 mm dia -- 02 nos

34

243

8283.08

... More
25 mm dia -- 02 nos

34

179

6096.88

... More
20 mm dia -- 02 nos

34

126

4306.78

... More
(v) Socket

-

-

-

... More
32 mm dia -- 04 nos

68

153

10410.8

... More
25 mm dia -- 02 nos

34

122

4175.88

... More
20 mm dia -- 06 nos

102

89

9086.16

... More
(vi) Reducer Socket

-

-

-

... More
25 mm dia-- 02 Nos

34

100

3421.42

... More
22 mm dia-- 04 Nos

68

83

5704.52

... More
Providing and fixing brass/ C.I stop cock of approved quality all compelte as per specifation and direction of E/I

-

-

-

... More
15 mm dia -- 04 nos

68

282

19195.72

... More
Providing and fixin gun metal full way valve of approved quality all complete as per specifation and direction of E/I 25 mm dia-- 01 Nos

17

586

9969.99

... More
Constructoin of Soak Pit for recharging of water

-

-

-

... More
Earth work in excavation foundation in ordinary soil and disposal of excavated earth as obtained to a distance upto 50m. Including roots of trees shurbs all complete as per approved design, building specification and direction of E/I (5.1.1)

52.87

151

8026.72

... More
Providing coarse clean sand in filling in foundation trenches and in plinth including ramming and watering in layers not exceed 150mm thick with all lead and lift including cost of materials labours royalty and taxes all complete as per building specification and direction. (5.1.10)

19.55

589

11524.92

... More
Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. ( 5.6.1)

33.37

356

11897.43

... More
Providing P.C.C.M-150 in nominal mix of (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, mixing cement concrete in mixer and placing in position,vibrating,curing,taxes and royalty all complete as per building specification direction of E/I. BCD-5.3.1.2

2.67

4598

12272.68

... More
Providing 250 mm thick brick jali work in C.M (1:8) in foundation with designation 75 A brick and approved quality of clean coarse sand finihed with deep ruled pointing in C.M (1:3) etc all complete job. ( analysed 5.2.25)

90.08

1309

117943.87

... More
Providing designation 75A brick work in C.M (1:6) in foundation and plinth with approved quality sand of F.M 2.5 including cost of screening racking out joints to 15mm depth curing royalty and taxes etc all complete job as per specification and direction of E/I.(5.2.3) Bottom of Brick jali

5

5439

27188.37

... More
Providing following materials as filter media in the pit of approved quality & size in layers as per drawing and direction of engineer in charge all complete job with all taxes and royalty

-

-

-

... More
(a) Aggregates (63mm to 45mm) (M-008) S.N-08

4.08

945

3855.6

... More
(b) Aggregates (53mm to 22.4mm) (M-007) S.N-07

4.08

1020

4161.6

... More
(c) Aggregates (10mm to 5 mm) (M-010) S.N-10

4.08

991

4043.28

... More
( c) Coarse sand (M-001))

4.08

393

1603.44

... More
Providing precast R.C.C M- 200 with Nominal mix (1:1.5:3) slab of desired size with approved quality of stone chips & clean coarse sand with all complete job.(5.3.4)

3.01

5247

15790.15

... More
Providing for Tor Toteinforcement as per approved design & drawing excluding carriage to work site including cutting bending binding etc all complete job. (5.5.4)

210.63

83

17547.59

... More
Providing 12mm cement plaster (1:6) with approved quality of clean coarse sand of F.M 1.5 including screening curing with all leads & lift of water scaffolding taxes & royalty all complete as per building specification and direction of E/I (5.7.3)

28.05

165

4650.69

... More
Providing, fitting and fixing suitable M.S grating wt. not less than 1.25 kg at inlet of soak pit & cleaning of site for execution of work as per direction of E/I.

17

100

1700

... More
Supplying all materials, Labour, equipments for constructing P.C.C drain as per unicef design etc. all complete including carrige of materials (Base rate)

51

491

25076.7

... More
Carriage of following materials to work site (avg lead) including loading unloading and taking etc. all complete as per building specification and direction of E/I

-

-

-

... More
Brick (6km lead)

12223

-

6967.11

... More
Sand (36km lead)

25.33

611

15477.64

... More
Stone Chips (11 km lead)

4.93

291

1434.83

... More
Cement (5 km lead)

4.08

156

638.23

... More
Steel reinforcement (5km lead)

0.17

156

26.59

... More
Platform near Tank

-

-

-

... More
Earth work in excavation in foundation trenches in hard soil vide classification item-B and disposal of excavated earth as obtained to a distance up to 50 m including all lifts,levelling,ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specifications and direction of E/I. For Platform

15.3

167

2560.15

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labours , royalty and taxes all complete as per building specification and direction of E/I.(mode of measurement compacted volume) For Plat Form

4.59

589

2705.85

... More
Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. For Plat Form

61.2

356

21819.02

... More
Providing P C C M-150 in nominal mix of (1:2:4)in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M2.5 to 3 including screening shuttering , mixing cement concrete in mixer and placing in position ,vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.

9.56

4598

43970.57

... More
Providing 12 mm thick cement plaster (1:3) with clean coarse sand of F.M 1.5 with 1.5 mm thick cement punning over it including screening, curing, with all leads and lifts of water, taxes and royalty all complete as per building specification an direction of E/I.

127.5

235

29966.32

... More
Carriage of following materials to work site (avg lead) including loading unloading and taking etc. all complete as per building specification and direction of E/I

-

-

-

... More
Brick (6km lead)

11084

-

6317.88

... More
Sand (36km lead)

19.55

611

11945.83

... More
Stone Chips (11 km lead)

8.67

291

2523.32

... More
Cement (5 km lead)

3.74

156

585.05

... More
Brick Masonry Bore well Protection Chamber

-

-

-

... More
Earth work in excavation in foundation trenches in hard soil vide classification item-B and disposal of excavated earth as obtained to a distance up to 50 m including all lifts,levelling,ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specifications and direction of E/I. For Platform

4.08

167

682.71

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labours , royalty and taxes all complete as per building specification and direction of E/I.(mode of measurement compacted volume) For Plat Form

3.06

5439

16645.94

... More
Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. For Plat Form

1.16

4598

5315.55

... More
Providing P C C M-150 in nominal mix of (1:2:4)in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M2.5 to 3 including screening shuttering , mixing cement concrete in mixer and placing in position ,vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.

161.5

82

13257.54

... More
Providing 12 mm thick cement plaster (1:3) with clean coarse sand of F.M 1.5 with 1.5 mm thick cement punning over it including screening, curing, with all leads and lifts of water, taxes and royalty all complete as per building specification an direction of E/I.

48.96

165

8117.57

... More
Carriage of following materials to work site (avg lead) including loading unloading and taking etc. all complete as per building specification and direction of E/I

-

-

-

... More
Brick (6km lead)

10353

-

5901.21

... More
Sand (36km lead)

10.37

611

6336.48

... More
Stone Chips (11 km lead)

1.02

291

296.86

... More
Cement (5 km lead)

2.21

156

345.71

... More
Steel reinforcement (5km lead)

1.62

156

252.63

... More
OPERATION AND MAINTENANCE

-

-

-

... More
Hence O & M Cost for 1st year (Excluding Repair Charges)

17

9000

153000

... More
O & M cost for 2nd Year = O & M for 1st Yr + 6% of O&M for 1st Year + Annual repairing Charges

17

9564

162595.14

... More
O & M cost for 3rd Year =1.06 x 2st year

17

10138

172350.84

... More
O & M cost for 4th Year =1.06 x 3rd year

17

10746

182691.9

... More
O & M cost for 5th Year =1.06 x 4th year

17

11391

193653.41

... More
Provision of one no SIM card & its recharging cost for RMC 800 Per Year (5 Year)

17

4000

68000

... More
Add 18% GST

1

969725

969725.27

... More
Add 1% Labour Cess

1

63570

63570.88



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.