Energy Department Tender
... More
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 28,000Document Cost
₹ 2,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_ENRGY_52276_8Bid Award Id
ViewTender No
Energy/EWD/Dhanbad/09/2021-22Tender Authority
Energy Department ViewPurchaser Address
-Website
http://jharkhandtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
b. 2x1.5 sq. mm.+1x1.5 sq. mm. earth wire ( street light + 5amp socket )
290
-
130
... More
c). 2x4 sq. mm.+1x4 sq. mm. earth wire
110
-
231
... More
d). 2x6.0 sq. mm.+1x6.0 sq. mm. earth wire
90
-
313
... More
e). 2x4 sq. mm.+1x4 sq. mm. earth wire ( AC wiring)
115
-
231
... More
f). 4x10.0 sq. mm.+2x6.0 sq. mm. earth wire ( for 3 phase Autoclave Machine)
75
-
561
... More
g). 4x10 sq. mm.+2x10 sq. mm. earth wire ( for 2nos. 3phase TPN MCB DB )
62
-
695
... More
S/F A Compact unit made of 8"X10" PVC box with phenlse laminated sheet cover in front fixed with 4 nos of 5 amp piano type switch and socket, and one no of 15 amp switch and soket well connected with suitable wire, earthing etc as reqd. Named as Computer board
a) 8"X10" PVC Box 1-nos @195.00 =195.00
b)5 amp switches 3-nos @29.00= 87.00
c)5 amp socket 3-nos @39.00=117.00
d)15 amp switch 1 no @82.00=82.00
e)15 amp socket -1 nos @82.00=82.00 TOTAL- 563.00
10
-
563
... More
Supplying and drawing following size of FR PVC insulated copper conductor single core cable in the existing surface / recessed Steel/ PVC conduit as required
a)1x 1.5 sq. mm( for inverter wiring)
254
-
30
... More
Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic laminated sheet cover in front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps. Piano type switch connection as reqd.
21
-
180
... More
Providing and fixing plain 16/0.20 mm twin twisted flexible FR PVC insulated copper cable in polythene sleeve of suitable size on the floor/wall of the table door etc as required
66
-
23
... More
Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic laminated sheet cover in front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps Piano type switch connection, as reqd.
40
-
298
... More
S/F 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 Amps’C’ series ,SP MCCB, in sheet steel enclosure , on surface or in recess with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc as reqd.
5
-
888
... More
S/F PVC/G.I. box of following size on surface or in recess with suitable size of phenolic laminated sheet cover infont including painting etc. as reqd. (a) 75 mmx75 mmx50mm deep/ (4”x4”)
56
-
95
... More
(b) 210 mmx206 mmx48mm deep/ (10”x12”)
31
-
195
... More
Supplying and fixing 2 pin 5 amps ceiling rose on the existing junction box/ wooden block including connection as reqd.
88
-
41
... More
Supplying and fixing batten/angle holder including connection etc as reqd.
57
-
55
... More
S/F of the Following way, single pole and neutral, sheet, MCB distribution board 240 volts on surface/recess, complete with tinned copper bus bar neutral bus bar, earthy bar detachable gland plate interconnections, phosphatized and power painted including earthing etc as required a) 8 way Double door
1
-
986
... More
b) 6way double door
3
-
986
... More
c) 4 way double door
5
-
881
... More
d) 2 way single door
9
-
347
... More
S/F following way three pole neutral, sheet MCB distribution board, 415 volts on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, Phosphatized and powder painted including earthing etc as reqd. (But without MCB/RCCB/ Isolator)
a) 4 way (4+12) , double door horizontal type
2
-
1848
... More
S/F following 240 volts, ‘C’ series/"B" series miniature circuit breaker suritable for lighting and other loads of following poles in the existing MCB DB complete with connection, testing and commissioning etc. as reqd.
a) 63 amp, TPN MCB
2
-
1136
... More
b) 6/32 amp MCB
46
-
160
... More
c) 40 amp DP MCB
4
-
590
... More
d) 63 amp DP MCB
3
-
612
... More
Chemical Earthing System Electrode Length 5 meter and dia 77mm , VFC powder for backfilling of the earth pit ( 4 bag)
4
-
6580.89
... More
Supplying laying 8 SWG copper wire at 0.50 meter below ground label for conductor earth electrode, including soldering etc. as reqd.
46
-
122
... More
S/F of the following size of exhaust fan including cutting the wall and fixing exhaust fan etc as required (Ortem/ Orient/Bajaj or equivalent)
(a) 9” sweep
2
-
1162.42
... More
S/F Following piano type switch / socket on the existing switch box cover including connection etc. as reqd.
a) Electronic step fan regulator , Delux
14
-
213
... More
S/F 48” AC ceiling fan with all accessories etc. as reqd. Make-Polar/bajaj/ havells.
14
-
1522
... More
S/F 16" wall mounted fan. Make-Polar/bajaj/ havells/anchor/ usha
19
-
2126.99
... More
S/F 9 watt L.ED BULB Make -Bajaj/C&S/HPL or equi
57
-
144.53
... More
S/F 20/22 watt L.E.D tubelight fitting including all accessories etc as reqd.Make-Bajaj/C&S/HPL or equi
48
-
657
... More
Supply of XLPE insulated sheathed (heavy duty) armoured electric cables with Aluminium conductor for working voltage 1100 volts conforming to IS:7098 (part-1)/IS:1554 a) 3.5x50 sq mm ( main service cable)
96
-
433.74
... More
b) 3.5x25 sq mm ( from Block A Main supply panel to Block B sub Panel main supply)
46
-
269.32
... More
b) 3.5x25 sq mm ( from Block A Solar panel to Block B Solar sub panel)
49
-
269.32
... More
b) 3.5x25 sq mm ( from Generator to main panel)
55
-
269.32
... More
c) 2x6 sq mm ( from Main Panel to office)
48
-
116.56
... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 35 sq. mm. direct in ground including excavation sand cushioning protective covering and refilling the trench etc. as reqd.
168
-
185
... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of1.1 KV grade of size exceeding 35 sq. mm. but not exceeding185 sq. mm.direct in ground including excavation sand cushioning protective covering and refilling the trench etc. as reqd.
85
-
192
... More
S/F following size aluminium luge a) 3.5x25 sq mm
4
-
9.84
... More
b) 2x6 sq mm
2
-
2.46
... More
c) 3.5x50 sq mm
2
-
17.22
... More
20 amps TPN enclosure with 3 pole and earth metal plug & socket for incorporating plug TP MCB
2
-
602.12
... More
S/F 40 amp TPN MCB in existing TPN DB Socket
2
-
1136
... More
S/F 50 mm dia medium class G.I pipes
15
-
377.04
... More
S/F 90 watt LED street light (Havells/Bajaj/Jaquar)
11
-
7516
... More
Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with approved shade, making PCC plinth and foundation including fitting and fixing, connectin, transportation up to work site, laboru charge etc all complete as reqd. ( Main Panel) a) 160 amps, 35 kA, fixed thermal setting MCCB (for Main incomer)-1 b) 100 amps, 4pole changeover -1 c) 63 amps, 16 kA, fixed thermal setting MCCB (outgoing) -3
d) Roatery handle- 4 g) DigitalVoltmeter - 1nos h) Digital Ammeter - 1nos I) Indcator - 3 nos. J) C.T coial - 3 nos 200/5 l) 50mm x5mm copper tape - 32 kg
1
-
89021.65
... More
Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with approved shade, making PCC plinth and foundation including fitting and fixing, connectin, transportation up to work site, laboru charge etc all complete as reqd. ( Solar Panel) a) 100 amps, 16 kA, fixed thermal setting MCCB (incomer) -1nos b) 63 amps 4pole Changeover -1
c) 63 amps, 16 kA, fixed thermal setting MCCB ( Outgoing) -2 e) 63 amp DP MCB - 8 d) Roatery handle- 4 g) DigitalVoltmeter - 1nos h) Digital Ammeter - 1nos I) Indcator - 3 nos. J) C.T coial - 3 nos 200/5 l) 50mm x5mm copper tape - 24 kg
1
-
63245.95
... More
Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with approved shade, making PCC plinth and foundation including fitting and fixing, connectin, transportation up to work site, laboru charge etc all complete as reqd. ( Solar Panel) a) 63 amps, 16 kA, fixed thermal setting MCCB (incomer) -1nos b) 63 amps 4pole Changeover -1
c) 63 amps, 16 kA, fixed thermal setting MCCB ( Outgoing) -2 e) 63 amp DP MCB - 5 d) Roatery handle- 4 g) DigitalVoltmeter - 1nos h) Digital Ammeter - 1nos I) Indcator - 3 nos. J) C.T coial - 3 nos 200/5 l) 50mm x5mm copper tape - 22 kg
1
-
58272.58
... More
Fabrication, installation with 16 SWG MS sheet with one coat steel primer and two coat spray painting with approved shade, making PCC plinth and foundation including fitting and fixing, connectin, transportation up to work site, laboru charge etc all complete as reqd. ( Main supply Sub Panel) a) 63 amps, 16 kA, fixed thermal setting MCCB (incomer) -1nos b) 63 amps 4pole Changeover -1
c) 63 amps, 16 kA, fixed thermal setting MCCB ( Outgoing) -1 e) 63 amp DP MCB - 6 d) Roatery handle- 4 g) DigitalVoltmeter - 1nos h) Digital Ammeter - 1nos I) Indcator - 3 nos. J) C.T coial - 3 nos 200/5 l) 50mm x5mm copper tape - 23 kg
1
-
53546.41
... More
Add GST@12%
1
-
147544.13
... More
Add Labour cess @ 1%
1
-
13770.78