Central Institute Of Mining And Fuel Research Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 16,386Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CSIR_181184_1Bid Award Id
ViewTender No
No23(1047)/2023-GA/(Elect.)/BCTender Authority
Central Institute Of Mining And Fuel Research ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
435
-
-
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
170
-
-
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
198
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
3 x 2.5 sq. mm
840
-
-
3 x 4 sq. mm
670
-
-
6 x 6 sq. mm
240
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm
110
-
-
25 mm
55
-
-
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
-
-
-
100 mm X 100 mm X 60 mm deep
10
-
-
180 mm X 100 mm X 60 mm deep
5
-
-
200 mm X 150 mm X 75 mm deep
4
-
-
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
-
-
-
5/6 amps switch
240
-
-
15/16 amp switch
41
-
-
3 pin 5/6 amp socket outlet
62
-
-
6 pin 15/16 amp socket outlet
41
-
-
Supplying and fixing TWO MODULE stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
23
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
-
-
-
1 or 2 Module (75mmX75mm)
73
-
-
3 Module (100mmX75mm)
73
-
-
6 Module (200mmX75mm)
6
-
-
8 Module (125mmX125mm)
17
-
-
12 Module (200mmX150mm)
3
-
-
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
10
-
-
Installation, testing , commssioning of wall bracket/ceiling fittings of all sizes and shapes contaioning upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
90
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
-
-
-
4 way (4 + 12), Double door
8
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole
96
-
-
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
10
-
-
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
40 amps
8
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
-
-
-
Above 35 sq. mm and upto 95 sq. mm
150
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
3½ X 95 sq. mm (45mm)
2
-
-
Supply, Installation, testing & commissioning of USB-A charger double port (2.5 , 5 V DC), 2 module (CRS certified) complete in all respect as required.
17
-
-
Supply, installtion, testing & commssioning of Power Distribution board madw with 18 SWG sheet , Double coated painted and complete in all respect of safety standards including following component. Aluminium Bus Bar Size: 40"X24"X10.5" , Incomer:(i) Auto ATS Switch 125 Amp.-: 01 No. , OutGoing:(i) 63 A,4 Pole MCB-: 03 Nos., (ii) 32 Amp. DP MCB-: 01 No. (Approval of Drawing and components must be taken before fabrication by Engineer-In-charge). (Switches Make -: L&T, Siemens, Schinder, C&S, Havells)
1
-
-
Dismantling of all the existing circuits , switch boards , distribution boards etc of complete building and depositing in Electrical Maintence section as required.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements