Central Coalfields Limited Tender

... More
The CCL has issued a formal invitation for competitive bids for the Central Coalfields Limited project, for Installation And Making Of Foundation Of Transformer 750 Kva,3.3kv/415v Rating With Protective Devices Near Mobile Crusher At Karma Project Under Kuju Area. in Ramgarh, Jharkhand, with an estimated contract value of Rs. 9,66,154. The bid opening date for this tender is 27-05-2025 and the last date for bid submission is 07-06-2025. Interested bidders for Central Coalfields Limited tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Central Coalfields Limited - CCL Tender

Works
Electrical Generators And Transformers
Eprocure
Opening Date27 May 2025
Closing Date7 Jun 2025
Tender Amount₹ 9,66,154 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Brick work with common burnt clay modular bricks of class designation7.5 in foundation and plinth in Cement mortar 1:6 (1 cement: 6 coarse sand) 2 Mtr X3 Mtr X 0.24 Mtr X2 Wall X 2 Nos= 7.48 CUM 2 Mu X 2.76 Mtr X 0.24 Mu X2 Wall X2 Nos=

7.48

-

-

... More
Supplying and filling in plinth with sand under floors, Including watering. ramming, consolidating and dressing complete

9.6

-

-

... More
Providing corrugated G S. sheet roofing including vertical / curved surfacefixed with polymer coated Jor L hooks, bolts and nuts 8 mm diameterwith bitumen and G.I. limpet washers or with G.I. limpet washers filledwith white lead, including a coat of approved steel primer and two coatsof approved paint on overlapping of sheets complete (up to any pitch inhorizontal vertical or curved surfaces), excluding the cost of purlins, raftersand trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/ m²

36

-

-

... More
Providing ridges or hips of width 60 cm overall width plain GS sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m

18

-

-

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1.3 (1cement: 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick

32

-

-

... More
upply & fixing fencing of chain link mesh 100 x 100 mm, 12 SWG GI wire for 2 for D.P. structure electric substation switch yard including single post of angla iron size 50x50x5mm, 2.5 mt long should be provided upto 2.00 ml apart or as required. The panel frame with required angle iron/ flat iron members/cross members including mesh welded in frame panel shall be erected between the posts. The angle iron post shall be erected in cement concrete M-15 (1:2:4) (20 mm graded metal) foundation including excavation of pit and refilling the same. The fencing shall be provided with one entrance gate including locking arrangement as required as per specification. The height of fencing shall be 2 mt. above groun level. Fencing shall be painted with required shade

230

-

-

... More
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm(7.14 kg per metre) double pole cross arm for three wire 11KVover head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm x 6 mm M.S. flats welded onone side to the channel iron and with bolts and nuts on the otherside for tying the cross arms together, Including drilling holes forinsulator pins/ fittings, bolts, nuts and washers etc (as per drawing)and painting with primer and finish paint as required

3

-

-

... More
Erection of pole of following length in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and uplo 12.00 metre

2

-

-

... More
Supply & Fixing of Aluminium Unarmoured single core flexible type 1100 voltage grade 35 sq mm

80

-

-

... More
Supply & Fixing of Aluminium Tubular Lug 35 sq mm

16

-

-

... More
Transformer Installation & Switch commissioning by providing man power

2

-

-

... More
Supply & Fixing of Nut & Bolts of diiferent size as required

50

-

-

... More
Supply & Fixing of Enamel Paint

20

-

-

... More
Supply & Fixing of Red oxide paint primer

20

-

-

... More
Supply & Fixing of Pad / Palm Connector, aluminium alloy material, 48.60 mm X 12 mm size.

6

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing structure as required. Upto 120 sq. mm

55

-

-

... More
Total impact of GST for the purpose of CTC

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.