Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Building Construction Department Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date23 Dec 2024
Closing Date30 Dec 2024
Tender Amount₹ 22,89,239 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removal of old tarfelt and disposal of debris with all leads complete job as per direction of E/l.

56.33

-

-

... More
Taking down old door and window shutters including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l.

11

-

-

... More
Taking down choukhat in doors including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l.

8

-

-

... More
Taking down choukhat in windows including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l.

3

-

-

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along the external wall below concrete or masonry apron us ing chemical emulsion @ 2.25 litres per linear metre includ ing drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration

52.35

-

-

... More
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

170.66

-

-

... More
Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.

17.17

-

-

... More
Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.

46.04

-

-

... More
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.

78.33

-

-

... More
Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I.

141.55

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

95.51

-

-

... More
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I.

78.33

-

-

... More
Providing two coats of plastic emulsion paint of approved shade and make over old surface including washing cleaning and preparing the walls scaffolding washing of floor and taxes all complete as per building specification and direction of E/I.

313.34

-

-

... More
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.

17.17

-

-

... More
Providing two coats of oil bound distemper of approved shade and make over old surface including washing cleaning and papering the walls, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/I.

154.55

-

-

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

46.04

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface

107.43

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm

2.1

-

-

... More
Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .

88.49

-

-

... More
Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

96.69

-

-

... More
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent

5.59

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work

11.18

-

-

... More
Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I.

0.14

-

-

... More
Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.)

345.6

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. '80x1 .25 mm M.S. laths with 1.25 mm thick top cover

17.28

-

-

... More
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).

17.28

-

-

... More
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.

17.28

-

-

... More
Providing Retro-reflective regulatory sign board of size 900 mm dia metre made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge

2.88

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

116.13

-

-

... More
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).

17.28

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):

10.37

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).

5.04

-

-

... More
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

4

-

-

... More
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.

4

-

-

... More
Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps :- (a) Surface preparation :-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jel including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equivalent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modilied repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. (b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." (c) 2nd Coat :- To apply the 2nd coat of two component acrylic modified, ready to-use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Waterproofing Brand: Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance - Chemical Base Part A. Acrylic copolymer, Part B Specially graded cementitious powder - Density 1.6 kg/l (mixed density) at +27°C Tensile Strength - 2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength-2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength ~4N/mm2 (According to FIP 5.15) Elongation at Break ~35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370) (d) Protection of treated surface with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope (1:120) towards tlre rain outlets in alternate panels of 2 mlx2ml keeping 6mm gap between the panel joint. lntegral water proofing admixture conforming to lS 2645 @ of 100 ml per bag of cement to be added in the screed concrete (paid separately for this ltems).-All corners shall be chamfered vrith 150mm X 150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / MYK Schomberg / Dr Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured." (e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc. Warrenty for five years.

80.48

-

-

... More
Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F M 2.5 io 3 including screening,shuttering,and mixing cement concrete in mixer with admixture of integral water proofing and placing in position,striking curing,taxes and royality all complete as per building specification and direction of E/l. Panels that has been left should be casted next day.-There should be 6 mm gap between Panels. Brand- Sika_Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421 ic , Dr Fixit Pidiproof LW+

80.48

-

-

... More
Providing and filling of 6mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade) as per drawings and technical specifications and direction of Engg in Charge (with 18% GST).Brand:-Sika Polysulphide, Fosroc-Thioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivalent.

80.48

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter

15.6

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend

16

-

-

... More
Shoe (Plain) 110 mm Shoe

16

-

-

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm

16

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complet

4

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

31.41

-

-

... More
Providing 250mm wide brick drain in cement mortar (1:6) with as. 150mm clear depth and 250mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.

52.35

-

-

... More
NEW DOOR ( 25 mm Thick Flush Door over 6mm Ply & 1mm Formica with Comp Fittings )

5.51

-

-

... More
WINDOW PANEL ( 6mm Ply & 1mm Formica with Comp Fittings )

240

-

-

... More
Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/ Sand 10 km

2.18

-

-

... More
Point wiring in PVC conduit, with modular type switch - Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required. Group - C

28

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FRPVC insulated copper conductor single/core cable in surface/recessed PVC conduit 2 way modular type switch phenolic laminated sheet cover suitable size M.S. box and earthing the paint with 1.5 sq.mm FRPVC

2

-

-

... More
Wiring for light/power plug with 2 x 4 sq.mm FRPVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 No. sq.mm FRPVC insulated copper conductor single core cable for loop earthing as required

15

-

-

... More
Wiring for Curcuit submain wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface of recessed PVC sonduit as required 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire

15

-

-

... More
2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire

15

-

-

... More
2x6 Sqmm + 1x6 sqmm earth wire (For ESSENTIAL TPN DB )

15

-

-

... More
4x10 Sqmm + 2x10 sqmm earth wire (For Normal TPN DB)

15

-

-

... More
Telephone Wiring in Existing Conduit:- Supplying and drawing following pair,0.5 sq. mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface/recessed PVC conduit as required.(2 pair)

15

-

-

... More
TV Wiring in Existing Conduit:- TV Cable in Existing Conduit: Supplying and drawing co-axial TV cable RG-6 grade copper conductor, PE insulated, with PVC sheath in the existing surface/recessed PVC conduit as required,

15

-

-

... More
S/F PVC conduit - Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required. 20mm

15

-

-

15

-

-

... More
S/F PVC /G.I. boxes - Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required. 75mm x 75mm x 50mm deep/(4" x 4")

6

-

-

... More
S/F Modular type switch/socket on the existing switch box including connection etc. as required 5/6 amp. Switch & 3 pin 5/6 amp. Socket/outlet

6

-

-

... More
3 pin 5/6 amp. Socket/outlet

6

-

-

... More
Telephone socket outlet

1

-

-

... More
TV antenna socket outlet

1

-

-

... More
S/F Modular type electronic fan regulator - Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

8

-

-

... More
S/F Modular Boxes, base & cover plate (Used for TV and Tele.) :- Supplying and fixing following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module (78 mm x 78 mm x 45 mm)

6

-

-

... More
S/F suitable size G.I. box with modular plate and cover in front on surface or in recess including P.F. 3 pin 5/6 amp. Modular socket outlet and 5/6 amp. Modular switch connection painting etc. as required

6

-

-

... More
S/F suitable size G.I. box with modular plate and cover in front on surface/recess including P/F 6 pin 15/16 amp. And 5/6 amp modular socket outlet and 15/16 amps. Modular switch connection as painting etc. as required

6

-

-

... More
S/F 3 pin 5 amp ceiling rose on the existing junction box wooden block including connection etc. as required

26

-

-

... More
ITC fluorescent fitting directly on surface - Installtion, testing and commissioning of Pre-wired, fluorescent fitting/compact fluorescent fitting of all type, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq.mm. FR PVC insulated, copper conduit.

16

-

-

... More
I.T.C of ceiling fan including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq.mm FRPVC with 1.5 sq.mm. FRPVC insulated copper conductor single core cable etc. as required

8

-

-

... More
ITC Exhaust Fan/Wall Fan upto 450 mm sweep :- Installation of exhaust fan / Wall Fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required.

2

-

-

... More
S/F T.P. MCB DB - Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door, Horizontal type

1

-

-

... More
6 way (4 + 18), Double door, Horizontal type

1

-

-

... More
S/F 5 amp. To 32 amp rating 240 volt "C" series miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection testing and commissioning etc. as required. 6/32 amps, single pole, "B" series

1

-

-

... More
S/F 'C' series, MCB - Supplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection, testing and commossioning etc. as required. 6/32A Single Pole

1

-

-

... More
40 amps, TPN

1

-

-

... More
50/63 amps, TPN

1

-

-

... More
S/F following rating single pole 240 volts isolator in the existing MCB DB complete with connection testing and commissioning etc. a srequired 40 amp

1

-

-

... More
63 amp

1

-

-

... More
S/F 20 amps SPN MCB industrial socket outlet - Supplying and fixing 20 amps volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps 'C' series, SP MCCB, in sheet steel enclosure, on surface or in recess with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.

4

-

-

... More
Earthing with G.I. earth pipe 4.5 mtr. Long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required.

1

-

-

... More
Copper earth plate elecrtode - Earthing with copper earth plate 600mmx 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (But with charcoal or coke and salt)

1

-

-

... More
S/L 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode including soldering etc. as required

15

-

-

... More
P/F lighting conductor final made of 25mm dia 30omm long copper tube having single pole at top with 85mm dia 3mm thick copper base plate including holes etc. complete as required

1

-

-

... More
Reverting sweating and soldering of copper/G.I. tape (with another copper G.I. tape base of the final or any other metalic object) as required

15

-

-

... More
P/F copper lightning conductor tape in horizontal run - Providing and fixing copper tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)

15

-

-

... More
P/F copper lighning conductor tape in vertical run - Providing and fixing copper tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)

15

-

-

... More
P/F testing joint made of 20 x 3mm thick copper strip 125mm long with 4 nos. of tinned brass bolts nuts check nuts and spring washers etc. complete as required

1

-

-

... More
MV Cable Laying upto 400 Sq mm in ground:- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc, as required.

15

-

-

... More
Providing and fixing of XLPE, Aluminium Armoured PVC Cable confirming to IS IS7908 (Part-1) 1988 0f grade 1.1KV. 3.5 Core 185 Sq. mm. 1.1 KV XLPE Al. Ar. Cable.

15

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 185 sq. mm (57mm)

2

-

-

... More
Supply of Ceiling Fan: Supplying and fitting of 1400 mm Sweep regular/ standared model AC ceiling fan , including connection with 1.5 sq mm copper wire, down rod of standared length(upto 30cm) withall accessories as required.

8

-

-

... More
12" ( 300mm ) Metal Exhaust Fan

2

-

-

... More
20/22 watt T5 Tube light fitting

16

-

-

... More
Supplying and fixing recess mounted 18 watt LED vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceiling including connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc. as required

1

-

-

... More
15/16 Watt Led Bulb

2

-

-

... More
TENSILE ROOF

360

-

-

... More
Add GST 18 %

0.18

-

-

... More
Add L.Cess 1 %

0.01

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.