Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 1,46,300Document Cost
₹ 10,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BCD_89959_1Tender No
06/E.E.,BCD/Building Div. Daltonganj/2024-25Tender Authority
Building Construction Department ViewPurchaser Address
-Website
http://jharkhandtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
121.34
-
-
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
40.09
-
-
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
75.77
-
-
Water proofing for Old and New Roof Slab Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps
-
-
-
(a)surface preparation-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint/ coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete Ponding test to be done after plugging all outlets and to be checked from soffit to identify see page, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt Ltd. MYK Schomberg Dr Fixit/Fosroc or equivalent Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mm X 150 mm fillet of mortar (Cement sand 1:4) admixed with acrylic polymer of Sikal Fosroc MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete
-
-
-
(b)1st Coat Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is still green 1st coat should be applied @150 kg/Sgm/coat For the purpose of measurement the entire treated surface will be measured."
-
-
-
(c) 2nd Coat-To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface 2nd coat should be applied @0.7 kg/ Sqmt/coat For the purpose of measurement the entire treated surface will be measured" After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it Waterproofing Brand. Sika Topseal 109hi Fosroc Brushbond RFX/Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance Chemical Base Part A Acrylic copolymer, Part B: Specially graded cementitious powder Density 1.6 kg/l (mixed density) at +27°C Tensile Strength 2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength -2 N/mm2 (concrete failure) (According to ISO 4624). Slant-Shear Bond Strength 4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370)
-
-
-
(d) Protection of treated surface with PCO The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1:5:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mm gap between the panel joint Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of of cement to be added in the screed concrete (paid separately for this items) Al corners shall be chamfered with 150mm X 150 mm fillet The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika India " Pvt. Ltd. MYK Schomberg Dr Fixit/Fosroc For the purpose of measurement the entire treated surface will be measured.
-
-
-
(e) Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand Sika India Pvt.Ltd. MYK Schomberg Dr Fixit/Fosroc. Warranty for five years.
655.5
-
-
Covering of treated surface with PCC Providing 25 mm thick Cement Concrete M20(1 1.5.3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cement concrete in mixer with admixture of integral water proofing and cleaned sand of F.M 2.5 to 3 including screening.shuttering, and mixing placing in position striking curing taxes and royality all complete as per building specifiction and direction of E/.Panels that has been left should be casted next day. There should be 6 mm gap between Panels Brand Sika Plastocrate plus, MYK proof WP 10. Fosroc-Conplast X421 ic Dr Fixit Pidiproof LW+
655.5
-
-
Providing and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade)as per drawings and technical specifications and direction of Ein Charge (with 18% GST) Brand Sika Polysulphide. Fosroc-Thioflex 600. Dr Fixit Pidiseal PS(42P, MYK Seal PS or Euivalent
655.5
-
-
Providing and laying rectified glazed ceramic floor tiles 300x300m or more (thickness to be specified by manufacture) of 1st quality conforming to IS:15622 with approved make in colours white, ivory, grey, fume red, brown laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments, etc all complete.
75.31
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
641.42
-
-
Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
595.17
-
-
Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
37.69
-
-
Providing and fixing 18 mm thick gang saw cut mirror polsihed premoulded and prepolishe) machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1: 4 91 cement : 4 coarse sand) with joints treated with white cement, mised with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels.
4.32
-
-
Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
48.11
-
-
Taking down old door and window shutters including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l.
24
-
-
Taking down chowkhat in windows including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l.
24
-
-
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.
10
-
-
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
10
-
-
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with
water proofing cement compound @ 0.253 kg/ sqm. This layer
will be allowed to air cure for 4 hours.
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
44.25
-
-
Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
0.24
-
-
providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)
0.02
-
-
Providing & fixing pressed steel door frames manufactured from commercial mild steel sheet of 1.25mm thickness including hinges ,jamb, lock jamb, bead and if requiredangle threshold of mild steel angle section 50 X 25mm, orangle threshold of mild steel angle section 50 X 25mm, orbase ties of 1.25mm pressed mild steel welded or rigidlyfixed together by mechanical means, adjustable lugs withsplit end tail to each jamb including steel butt hinges split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and 2.5mm thick with mortar guards, lock strike-plate andshock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by the Engineer Incharge - Profile - B - Fixing with adjustable lugs with split end tail to each jamb
126.2
-
-
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges
with necessary screws
53.34
-
-
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :
Decorative plywood one side decorative veneer and commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type
229.66
-
-
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately)
Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
-
-
-
Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
113.1
-
-
Providing and fixing 25mm thick pre-laminated medium density fibre board exterior grade ( Grade-I) IS:14587:1998 marked with one side decorative and other side balancing lamination for cupboard shutters edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with necessary screw etc all complete.
127.8
-
-
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete
-
-
-
Twin rubber stopper
42
-
-
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
21
-
-
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
952.77
-
-
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
1641.05
-
-
Providing two coats of plastic emulsion paint of approved shade and make over old surface including washing, cleaning and preparing the walls, scafolding, washing of floor and taxes all complete as per building specification and direction of E/l.
2587.24
-
-
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
1515.39
-
-
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l.
171.54
-
-
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
27
-
-
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/l.
27
-
-
Providing 250mm. wide brick drain in cement mortar (1:6) with av. 250mm. clear depth and 250mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l.
55
-
-
Providing & fixing on wall face unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
90
-
-
Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
-
-
-
110x110x110mm
24
-
-
Shoe (Plain)
-
-
-
110mm shoe
12
-
-
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less thaN 440 grams.
12
-
-
Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means 50X50X50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc. complete - 110mm
72
-
-
Supplying, materials and labour for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600X450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600X475mm G.I. cover with frame (weight not less than 35kg) alongwith earth work in excavation and 80mm thick PCC (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
4
-
-
Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7),humidity resistance of 100%, thermal conductivity 0.043 W/m Kas per ASTM 518:1991, in true horizontal level suspended on interlocking section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black),comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross- T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm Code Description Unit Rate No.523 SUB HEAD : 26.0 NEW TECHNOLOGIES AND MATERIALS outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications,drawing and as per directions of the Engineer-in-Charge.
-
-
-
With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles
74.52
-
-
Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc.with auto closing spring loaded hinges (hydraulic type) etc. completeas per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately)
20.04
-
-
100mm SS fancy handles for kitchen cabinet
10
-
-
CARRIAGE OF MATERIALS
-
-
-
Bricks (7+1= 8KM)
3.65
-
-
Coarse Sand ( 12 KM.)
24.71
-
-
Stone Chips 22 KM.)
3.13
-
-
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
10
-
-
Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mm
1
-
-
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
10
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
14
-
-
Supplying, fitting and fixing gun metal full way valve of approved quality all complete as per specifcation and direction of E/I.
-
-
-
25mm dia.
3
-
-
32mm dia
3
-
-
40mm dia
2
-
-
Providing and fixing brass stop cock of approved quality all complete as per specification and direction of E/I. … 15mm dia.
23
-
-
Cutting chajjas or concrete for laying PVC Pipe and restoring the same with R.C.C. (1:2:4) brick work in cement Mortar (1:4) and cement plaster 1:4 as per specifiction and direction of E/I
12
-
-
Making holes in walls for PVC Pipe and restoring the same atfer pipe Laying (b) 250mm thick wall
18
-
-
Cutting drain width wise above GL for laying PVC pipe and restoring brick work in cement mortar (1:4) 12mm cement plaster in C.M. (1:4) with neat cement punning as per specifciation and direction of E/I. (PVC 110mm dia)
6
-
-
Making holes in wall for laying PVC pipes and restoring the same all cost complete (PVC pipe 110mm dia)
18
-
-
Supplying all tolls and labour and cutting chajja cornice for laying PVC pipes and making good the same as per specification and direction of E/I. (110mm dia PVC pipe)
18
-
-
Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 10% for labour and Contractors profit)
-
-
-
Bib cock - long thread (Basic rate Rs.728.15 + 10% for C.P. & laying charge)
10
-
-
Angular stop cock L.T.(Basic rate Rs.610.65 + 10% for C.P. & laying charge)
15
-
-
Pressure adjustable shower with revolving joint (Basic rate Rs.817.55 + 10% for C.P. & laying charge
10
-
-
32mm dia. PVC waste pipe 750mm long with coupling (Basic rate Rs.62.40 + 10% for C.P. & laying charge
10
-
-
15mm C.P. nipple with coupling(As per basic rate Rs 87.20 + 10% C.P. & laying charge)
20
-
-
Steel jali - 100mm dia. (Basic rate Rs.48.20 + 10% for C.P. & laying charge
20
-
-
Flush Valve complete with 32 mm size control cock & Flange (Basic rate Rs.3499.85 + 10% for C.P. & laying charge
10
-
-
Providing Solvent cement (as per basic item - 168 + 10% C.P & laying charge
5
-
-
Supplying, fitting and fixing C.P. brass towel rail 20mm X 600mm with bracket container
20
-
-
Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply board and c.p. hinges to fix with mirror. (i) 600mm X450mm size
24
-
-
Supplying, fitting and fixing C.P. brass soap dish container medium quality with screw and hinges etc.
25
-
-
Providing and fixing C.P. brass bib cock of approved quality conforming to IS 8931, 15mm dia nominal bore of approved brand C.P. fittings
10
-
-
Providing and fixing PTMT extension nipple 15mm size with 12" BSP thread 70mm length and 30mm breadth and weighing not less than 18gms of approved make
8
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i.e fixing the pipe with clamps at 1Mtr. Spacing. This includes jointing of the pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the walls etc.
-
-
-
15mm nominal bore
85
-
-
20mm nominal bore
50
-
-
25mm nominal bore
120
-
-
External work - 40mm nominal bore
80
-
-
Providing & fixing on wall face unplasticised - Rigid P.V.C. pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
90
-
-
Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
-
-
-
Single Tee with door
-
-
-
110x110x110 ,mm
14
-
-
Bend 87.5 degree
-
-
-
110 mm bend
24
-
-
Providing and placing on terrace (at all floor levels) (PVC) Polyethylene water storage tank ISI 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
4000
-
-
Point wiring in PVC conduit, with modular type switch - Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required.
-
-
-
Group - B
14
-
-
Wiring for light/power plug with 2 x 4 sq.mm FRPVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 No. sq.mm FRPVC insulated copper conductor single core cable for loop earthing as required
70
-
-
Wiring for Curcuit submain wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface of recessed PVC sonduit as required
-
-
-
2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire
45
-
-
2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
20
-
-
Supplying recess mounted 18 watt LED vertical downlighter complete .
10
-
-
S/F 20 amps SPN MCB industrial socket outlet - Supplying and fixing 20 amps volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps 'C' series, SP MCCB, in sheet steel enclosure, on surface or in recess with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
4
-
-
Supplying recess mounted 36 watt LED panel light (2x2) complete .
4
-
-
Add 18 % GST (in Basic Rate must fill 12)
18
-
-
Add 1% Labour Cess (in Basic Rate must fill 1)
1
-
-