Building Construction Department Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Building Construction Department - BCD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date12 Jun 2024
Closing Date19 Jun 2024
Tender Amount₹ 55,48,902 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume)

74.71

-

-

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume).

30.88

-

-

... More
Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building spedification and diection of E/I.

191.21

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

18.97

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finshing and reinforcement- All work up to plinth level 1:1.5:3 (1 cement :1.5 coarse sand (Zone-III): 3 graded stone aggregate 20mm nominal size)

18.13

-

-

... More
Reinforce cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, post and struts etc. Above plinth level up to floor five leve, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement: 1.5 coarse sand (Zone-III) :3 graded stone aggregate 20mm nimonal size)

11.26

-

-

... More
Reinforced cement concrete owrk in beams, suspended floors, roofs having slope up to 15 ° landing, balconies, shelves, chajjars, lintels, bands, plain window sills, staicases and spiral stair cases above plinth level up to floor five level, excluding the cost of centeri, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand (Zone-III): 3 graded stone aggreagte 20 mm nominal)

57.23

-

-

... More
Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing, cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position (including carriage of bars to work site) all complete as per building specification and direction of E/l. TMT Fe 500 .(only valid for SAIL & TATA(Tiscon),JSPL.Electrosteel Steel Ltd. Bokaro And Vizag(RINL))

3.06

-

-

... More
providing Tor steel reinforcement of 10mm to 16 mm dia bars as per approved design and drawing, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position (including carriage of bars to work site) all complete as per building specification and direction of E/I.(only valid for SAIL & TATA(Tiscon),JSPL.Electrosteel Steel Ltd. Bokaro And Vizag(RINL))

2.99

-

-

... More
providing Tor steel reinforcement of 12mm,& 16mm. dia bars as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.(only valid for SAIL & TATA(Tiscon),JSPL.Electrosteel Steel Ltd. Bokaro And Vizag(RINL))

3.99

-

-

... More
Centering and shuttering including struting, propping etc and removal of form for foundation, footings, bases for columns, etc. For mass concrete

37.44

-

-

... More
Centering and shuttering including struting, propping etc and removal of form for Columns, Pillars, Piers, Abutment, Post and struts

156.24

-

-

... More
Centering and shuttering including struting, propping etc and removal of form for Lintels, beams, Plinth Beams, girders, Bressumers and cantilevers

214.47

-

-

... More
Centering and shuttering including struting, propping etc and removal of form for Suspended floors, roof, landings, balconies and access platform.

227.48

-

-

... More
Providing designation 75B brick work in CM (1:6) in foundation and pling with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per buildding specification and direction of E/I.

15.19

-

-

... More
Providing designation 100A Brick Work with Fly Ash lime Brick (FALG) conforming to IS 12894-1990 (9"x4.5"x3") in cement mortar (1:6) in Superstructure with approved qualilty of clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints cost of screening, raking out joints to 15mm depth, curing, taxes sand royalty all complete as per building specification and direction of E/I.

70.61

-

-

... More
Providing designation 112mm thick reinforced designation 100A B/W with Fly Ash lime Brick (FALG) conforming to IS 12894-1990 (9"x4.5"x3") in cement mortar (1:4) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.

148.79

-

-

... More
Supplying, fitting and fixing 30mm thick solid core type non-decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.

31.84

-

-

... More
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin- Charge.

39.6

-

-

... More
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 1 9 gauge thickness and size of 1 9 mm x 1 9 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 1 1 5 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 1 0 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 1 5 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing. 30 mm thick plain PVC door shutters

12.6

-

-

... More
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.

13

-

-

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (i) Single rubber stopper

15

-

-

... More
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having band logo with ISI, IS:3564, embossed on the dody,, door weight upto 36kg to 80 kg and door width from 701mm to 1000mm with double speed adjustment with necessary accessories and screws etc. complete.

15

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

277.2

-

-

... More
Providing and fixing pressed steel door frames conforming to IS:4351, manufactured from commercial mild steel sheet of 1.60mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by E/I.

75.24

-

-

... More
Supplying, fitting and fixing M.S. grill made of 20x6cmm M.S. flat/square bar as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/i.

451.2

-

-

... More
Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20x10x2mm at 100mm centers and braced with M.S. flat diagonals 20x3mm with top and bottom rails of T.iron 40x40x6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I.

6.89

-

-

... More
Providing and laying, Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622/ISO: 13009 of approved make in all colour and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry@3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete size of tile 600x600mm

141.73

-

-

... More
Providing and fixing granite 18mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills, facias and similar locations of requied size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.

4.72

-

-

... More
Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. With "A" grade white 15X15cm Tiles.

53.23

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in colours such as white, lvory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry@3.3kg/sqm including pointing the joints with white cement and matching pigment etc. complete.

14.21

-

-

... More
Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. (iv) 600X600 mm size

40.95

-

-

... More
Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1:3) and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.

6.17

-

-

... More
Providing and laying pressed clay tiles (as per approved pattern 20mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral waterproofing compound, laid over a bed of 20 mm thick cement mortar1:4 (1 cement : 4 coarse sand) and finished neat complete.

39.63

-

-

... More
Providing and filling of 6 mm thickGroove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade)as per drawings and technical specifications and direction of E in Charge.(with 18% GST) Brand :- Sika-polysulphide, Fosroc-Thioflex 600, Dr. Fixit Pidiseal PS (42P) MYKSeal PS or Equivlent

112.58

-

-

... More
Water proofing for Old and New Roof Slab :- Providng and laying water proofing treatment on roof slab by applying tow component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofing coating as per manufacturer specification-With following steps:- (a) Suface preparation:- Providing and cleaning of concrete surface to remove dust, Oil, grease including removal of existing loose paint/ coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools, complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On indentification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt. Ltd. / MYK Schombeg/Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc. Shall be chamfered with '150mmX'150mm fillet of mortar (Cement sand- 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr Fixit or requivalent Before chamfering a prime coat shall be given with the slurry of acrylic polymer Reparing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all materials labour, tools, complete. (b) 1st Coat :- Apply 1st coat of two component acrylic modidied, ready to use, flexible cementitious material on surface saturated dry roof and inisde wall of Parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm oil Fibre glass cloth to lay when the fist layer is still green. 1st coat should be applied @1.50/kg/sqmt/coat for the purpose of measurement the entire treated surface will be measured." (c) 2nd Coat :- To apply the 2nd coat of two component acrylic modified ready to use flexible cementitious materials right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied@ 0.7kg/sqmt/coat. For the purpose of measurment the entire treated surface will be measured." after three days of drying the 2nd coat, the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, teakage from soffit and if found necessary rectification to e be done as per satisfation of E/I. the waterproofing coating to be protected from damage before screed over it.The Waterproofing Brand: *Sika Topseal 109hi/Fosroc Brushbond RFX/ Dr Fixit Pidiffine 2K/MYK Aquafin TG Product Performance- Chemical Base Part A.Acrylic copol,mer, Part B Specially graded cementitious powder-Density 1.6 kg/l (mixed density) at +27° Tensile Strength -2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strenth-2 N/mm2 (concrete failure) (According to ISO.4624) Slant-shear Bond Strength-4 N/mm2 (According to FIP 5.15) Flongation at Break- 35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTMD 2370) (d) Protection of treated surface with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in alternate panels of 2mtx2mt keeping 6mm gap between the panel joint integral water proofing admixture conforming to IS2645@ of 100 ml perbag of cement to be added in the screed concrete (paid separately for this items) all corners shal be charfered with 150mmx150mm fillet. The rain water outlets shal be just leveled with the screed concrete to ensure smooth descharge of water- the perpheral gaps between PVC pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensisive epoxy putty of Sika India Pvt.Ltd./MYK Schomberg/Dr Fixit / Fosroc. For the purpose of measurement the entire treated surface will be meaured."

-

-

-

... More
(e) Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand-Sika India Pvt. Ltd./MYK Schomberg/ Dr Fixit/Fosroc.Warranty for five years

107.45

-

-

... More
Covering of treated surface with PCC :- Providing 25 mm thick Cement Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6mm size graded and cleaned sand of F.M. 2.5 to 3 including screening, shuttering, and mixing cement concrete in mixer with admixture of interggral water proofing and placing in position, striking curing, taxes and royality all complet as per building specification and directionof E/I. Panels that has been left should be casted next day . There should be 6 mm gap between panels brand sika_Plastocrate plus, MYK proof WP10, Fosroc-Conplast X421 ic, Dr. Fixit Pidiproof LW+.

107.45

-

-

... More
Providing 12mm thick cement plaster (1:6) with clean coarse sand of FM 1.5 including screening curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I

1073.03

-

-

... More
Providing 6mm thick cement plaster (1:4) in ceilling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.

169.98

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

1243.01

-

-

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

434.62

-

-

... More
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolidng washing of floors and taxes all complete as per building specification and direction of E/I.

808.39

-

-

... More
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)

22.56

-

-

... More
Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including preparing the surface after cleaning, removing dirt, scales, smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.

71.64

-

-

... More
Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all complete as per building specification and direction of E/I.

32.89

-

-

... More
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.

22.56

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominla size) over 75mm thick bed of dry brick ballast 40mm nominal size, wall rammed and consolidated and grouted with fine sand including necessary excavation, levelling & dressing & finishing the top smooth all complete as per specification and direction of E/I.

25.69

-

-

... More
Providing and fixing circular/hexagonal cast iron of M.S. Sheet box for ceilling for clamp, of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. Sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S sheet box by means of 3.3nn dua riybd geaded screwsm ibe kicj at tge cormers, Clamp shall be made lf 12mm dia M.S. bar bent to shape as per standard drwaing.

13

-

-

... More
Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of earth work involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.

45.16

-

-

... More
Carriage of Materials-

-

-

-

... More
Bricks Lead (7P+1K=8km)

15024

-

-

... More
Fly Ash Bricks (7P+1K=8km)

36404

-

-

... More
Sand Lead = (1K+4P =5 km)

135.5

-

-

... More
Stone Chips Lead (7P+1K=8km)

87.62

-

-

... More
Local sand Lead = (3km)

74.71

-

-

... More
Providing 12 mm Thk. cement plaster(1:3) with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I

40.42

-

-

... More
Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I.

40.42

-

-

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

-

-

... More
Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750 mm deep, 600 x 450 internal dimension having 250 mm wall thickness in cement mortar ( 1:6 ) including 12 mm cement plaster ( 1:4 ) with punning on inside and cement plaster (1:6 ) with 600 x 475 mm G.I. cover with frame (Weight not less than 36 Kg.) along with earth work in excavation and 80 mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/l.

2

-

-

... More
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. Group C

70

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.

70

-

-

... More
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.

-

-

-

... More
2x1.5 sq mm + 1x1.5 sq mm earth wire

200

-

-

... More
2x2.5 sq mm + 1x2.5 sq mm earth wire (1.7.2)

235

-

-

... More
4x2.5 sq mm + 2x2.5 sq mm earth wire (1.7.8)

45

-

-

... More
4x10 sq mm + 2x6 sq mm earth wire. (1.7.11)

40

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/PVC conduit as required.

100

-

-

... More
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm dia

50

-

-

... More
25 mm dia

100

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 amps one way switch

35

-

-

... More
15/16 amp one way switch

20

-

-

... More
5/6 amp 3 pin socket outlet

35

-

-

... More
5/16 amp 6 pin socket outlet

20

-

-

... More
TV anteena Socket Outlet

4

-

-

... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

13

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

10

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required

-

-

-

... More
. 1 or 2 Module (78mm x 78mm x 45mm) - For Telephone & TV outlet.

4

-

-

... More
4/5 Module (78mm x140mm x 50mm)

45

-

-

... More
6 Module (78mmX205mmx50mm)

3

-

-

... More
Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required.

14

-

-

... More
Supplying and fixing batten/ angle holder including connection etc. as required.

2

-

-

... More
Supplying and fixing Ding dong sound call bell single phase, 230 volts, complete as required.

2

-

-

... More
Installation of exhaust fan up 450 mm sweep in the existing opening including making the hole to suit the size of above the fan, making good the damage, connection, testing, commissioning etc. as

5

-

-

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (JSR-2.18)

5

-

-

... More
Supplying and fixing following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 Way (4+24), Double Door Horizontal Type

2

-

-

... More
Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA "C" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required.

-

-

-

... More
6 / 32 Amp Single Pole

25

-

-

... More
40 Amp TPN

2

-

-

... More
Supplying and fixing Single pole blanking plate in the existing MCB DB complete etc. as required.

5

-

-

... More
Supplying and fixing of following rating double pole ( Single Phase & neutral), 240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required. 40 Amps (2.16.2)

5

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.

1

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

20

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

30

-

-

... More
Supply of XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (conforming to IS-1554. (Part-I). 4 core, 16 sq.mm.

25

-

-

... More
S.I.T.C of following rating reccess/ surface mounted LED round/ square shape down light luminarie with pressure die cast housing for single phase Supply voltage. Luminarie shall be confirm to IS: 10322 part- 5/ Section- 2 or IEC: 62722 with all neccessary accessories as required. 18 /20 W LED Round Down Light (Surface) (JSR-9.3.4)

4

-

-

... More
Bulk Head fitting with 9/10 Watt. LED/CFL

2

-

-

... More
S.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz, Single Phase Supply etc. complete as required.

-

-

-

... More
10/12 W LED Tube Light

5

-

-

... More
20/22 W LED Tube Light (JSR-9.5.2)

13

-

-

... More
Supply of 300 mm (12") Exhaust fan (Metal body)

5

-

-

... More
Supply installation, testing and commissioning of follwing size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm. FR PVC insulated, copper wire suitable for 230V 50HZ, single phase suppy etc. complete as required. 1200 mm ( 48") Ceiling Fan

13

-

-

... More
Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. Approved make with 100mm H.C.I. 'P' trap 15 liters C.I. Pull and let go flushing cistern of names or other I.S.S.equipment make, complete with all fittings, C.I. or C.c. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull inlcuidng supplying and fixing a pair of vitreous white glazed earthenwere were footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specificaiton and direction of E/I. (A) 580 mm. long (C) with 10lit low Level PVC Cistern

4

-

-

... More
Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C. With 'P' trap of parry Hindustan or any othe approved I.S.S. Make including supplying and fixing 15 litres C.I. Mosquito proof low down flushing cistern of approved make with complete fitting with C.I. handle and R.S. or bracket with telescope flush pipe with brass coupling and plumbers joint spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm long with bras coupling at both ends and white/blcok plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinger or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I. (b) With 10 ltr low level PVC cistern

4

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps

5

-

-

... More
Supplying, fitting and fixing the following items complete with all materiasl as per specification and direction of E/I. (a) glass shelf with C.P. Brass rail (i) 600x125mm glass shelf complete

4

-

-

... More
Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms

5

-

-

... More
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.

5

-

-

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

5

-

-

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore

6

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore

13

-

-

... More
Providing and fixing toilet paper holder : C.P. brass

1

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 0 mm gap for thermal expansion, (i) Single socketed pipes.

-

-

-

... More
75 mm diameter

30

-

-

... More
110 mm diameter

70

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 0 mm gap for thermal expansion.

-

-

-

... More
Coupler: 110mm

30

-

-

... More
Single tee with door 110x110x110mm

4

-

-

... More
Bend 87.50 110mm dia

3

-

-

... More
Shone (Plain) 110mm dia

3

-

-

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1 : 4 (1 cement: 4 coarse sand) and making good the wall etc. complete.

-

-

-

... More
110mm dia

10

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc

-

-

-

... More
15 mm nominal dia Pipes

35

-

-

... More
25mm nominal outer dia pipes

65

-

-

... More
32mm nominal outer dia pipes

30

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall

-

-

-

... More
25 mm nominal dia Pipes

30

-

-

... More
32mm nominal outer dia pipes

25

-

-

... More
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.

2

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI :12701 marked with cover and suitable locking arrangement and making necessary hole for inlet, oulet and over flowpipes but without fitting and the base support for tank.

2000

-

-

... More
Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressure and equipments as well as fuel, lubricants and cost of transportation of rig machine annd other vehicle up to Site. (Basic Rates)

-

-

-

... More
(a) From 0.00 M to 50.00 M below G.L.

50

-

-

... More
(b) From 51.0 M to125.00 M

50

-

-

... More
(c) From126.0 M to150.00 M

25

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia.

25

-

-

... More
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge

2

-

-

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia

1

-

-

... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp

1

-

-

... More
Supplying 100mm dia submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10/ 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 1.5 HP

1

-

-

... More
Supply fitting and fixing of standared make starter pannel Board with arrangement of all necsssury protection including all taxes, all complete job as per direction of E/I.

1

-

-

... More
Supply of FR PVC insulated 3 core 4 sqmm copper wire

100

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes

90

-

-

... More
Add 18 % GST (in Basic Rate must fill 12)

18

-

-

... More
Add 1% Labour Cess (in Basic Rate must fill 1)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.