Building Construction Department Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Building Construction Department - BCD Tender
Civil And Construction
Eprocure
Opening Date19 Jun 2024
Closing Date26 Jun 2024
Tender Amount₹ 71,43,861
Costs
EMD
₹ 1,42,900Document Cost
₹ 10,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BCD_86714_1Bid Award Id
ViewTender No
BCD/EE,Building Div.Jamshedpur-05/2024-25Tender Authority
Building Construction Department ViewPurchaser Address
-Website
http://jharkhandtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
35.83
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
80.6
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
8.46
-
-
Providing and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor,etc., up to floor five level, excluding the cost of centering,shuttering and finishing :1:1½:3 (1 cement:1½ coarse sand:3 graded stone aggregate 20 mm nominal size)
5.5
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
17.32
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
1.13
-
-
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
22.95
-
-
Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets,kerbs and steps etc.
44
-
-
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
9
-
-
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
61.5
-
-
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
41.4
-
-
providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for tata(Ticon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL))
2.08
-
-
providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. (a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
1.15
-
-
providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. (a) 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
1.74
-
-
Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20x6mm M.S. flats or 16mm square bars fitted on 25x25x6mm M.S Angle frame including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l. (where steel is not supplied by the deptt.)
30.38
-
-
Providing designation 75A one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I.
301.26
-
-
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
172
-
-
Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
6.25
-
-
Providing 1.5 mm. cement punning including curing carrage of water withall leads and lifts as per building specification and direction of E/I
28.25
-
-
Provideing 25 mm thick water proff plaster (1:3) with clean coarse sand of F.M 1.5 with 5% cico or any other apporoved water proffing compound including screening , curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specefication and direction of E/I
28.25
-
-
Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/l.
124.6
-
-
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)
330.03
-
-
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l.
330.03
-
-
Extra for providing and mixing water proofing material 'Impermo' or equivalent in cement concrete work @ 1 kg per 50kg of cement.
9.23
-
-
Cairage Of Meterial
-
-
-
Sand 5 Km
232.3
-
-
Aggregate 5KM
97.89
-
-
Brick
19.42
-
-
Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I.
22
-
-
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
-
-
-
(a) From 0.00 M to 50.00 M below G.L.
50
-
-
(b) From 51.0 M to125.00 M
75
-
-
(c) From126.0 M to150.00 M
25
-
-
Earthwork in stripping by hydraulic M/C in grade A&B type of soil including morrom soil, soil mixed with kankar, pebbles, boulders upto 300mm size and disposal of the same along with all organic materials in the country side beyond 1km upto 2Km in all by tipper including construction & maintenance of haul road etc. all complete as per specification and direction of E/I.
1105.5
-
-
Supplying submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.
Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages
2 HP
1
-
-
Supplying Full automatic star selta starter to operate induction motor working on 415v 3phase 50hz with no coil. Over load element , On _OFF push buttom with necessary materials and connection to Supply etc complete starter with original sheel steel encloser as per 3914.
F.A.S.D starter upto 5 H.P
1
-
-
Supply fitting and fixing GI pipe 50 mm Dia (TATA or equivalent make) Medium Quaility as per IS:1239 ( part 01 ) 2004
115
-
-
Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.( Make-Polycab/Incab/Rajnigandha Cables/Havells/ KEI/RR Kable) Supply & Erection of 32CX2.5 Sq. Cu. Flexible Wire for connection of light fitting.
170
-
-
P/F 25x5mm GI strip in ground: Providing and fixing 25mmX 5mm G.I. Strip at 0.5m below ground as strip earth electrode as required.
110
-
-
MV cable Laying upto 25 Sqmm in ground without sand and cover: Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 35 sq.mm. direct in ground but excluding , sand cushioning, protective covering as required.
300
-
-
MV cable Laying upto 120 sqmm in ground: Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size exceeding 35 sq.mm. but not exceeding 120 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
60
-
-
Erection of metalic Pole of following length in cement concrete 1:3:6 ( 1 cement:3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc as required. Above 8.00 metre and upto 11.00 metre
11
-
-
Supply and fixing of 45/48 W LED street light fitting ,with die cast aluminium housing of ingress protection of IP65 and complete with all accessories etc on pole including connection and earthing the body etc as required. Make- Bajaj/ Philips/ Havells.
10
-
-
S.I.T.C. of following rating LED Post top lamp made in die cast aluminium housing with decorative clear/opal acryclic diffuser on existing pipe including connection with 1.5 sq. mm copper conductor etc all complete as required. 20/25 W LED Post top lamp opel
41
-
-
Silent DG Set 10kVA: Supply, installation, testing & commissioning of 10kVA, DG Set, 415V, 3 phase, of Genset-CJ10D5P with engine-X1.3TAAG1 complete with manual panel including one EOD breaker of suitable rating, radiator dry battery and fuel tank , canopy enviroment friendly, sound less Kirloskar make
1
-
-
3 core PVC insulated PVC sheathed copper conductor flat submersible cable.
Supplying , Flat flexible submersible cable with ,copper conductor , PVC insulated and PVC sheathed as IS:7098
3 Core 4 Sq mm
130
-
-
3.5CX25 sq. mm armoured AL Cable.( for DG supply)+ Feeder pollars
130
-
-
HT 11kV , 3.5CX35 Sq.mm XLPE CABLE : Providing and fixing of Brand Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with extruded Semi Conducting Compound in combination with Copper Tape, cores laid up, innersheath of PVC tape, galvanised flat steel strip armoured and overall PVC Sheathed Cable conforming to IS 7098 / (PART-II) 1985 with latest amendments.
40
-
-
3.5 Core 70 Sq mm (tr to Main panels - JSEB supply)
70
-
-
7.0m height Octagonal Hot -dip glavinized pole(BOP-7030) :Supply, installation of 7.0m height OctagonalHot -dip glavinized pole with top dia 70mm, bottom dia 130mm & made of 3mm thick sheet, base plate dimension 200x200x12mm(L X B X T) including suitable sizes of foundation bolt all complete as required.( without arm)
10
-
-
0.5m single arm suitable for 70mm top pole
10
-
-
4CX10 sq. mm armoured AL Cable.( for street light)
340
-
-
outdoor stand mounted Feeder Panel with 63amp TP&N, MCB incomer.
53amp TP contactor automatic switching of luminaries, power tool
control incommer outgoing terminal etc as reqd. (for high mast)
2
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 120 Sq.mm
30
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
3.5 core x 25 Sq.mm
2
-
-
3.5 core x 70 Sq. mm
2
-
-
Supplying and making out door cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core XLPE aluminium conductor cable of 11 kV grade as required. upto 70 Sq.mm.
2
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
29.7
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer all complete.
4167
-
-
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
164
-
-
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and
pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3
coarse sand) and jointed with grey cement slurry mixed with pigment to
match the shade of the slabs, including rubbing and polishing complete.
20.4
-
-
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 0.80 mm thick with zinc coating not less than 275 gm/m²
164.28
-
-
Providing & fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. Single socketed pipes. 110mm dia
32
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
-
-
-
Bend -110 mm
16
-
-
Shoe - 110mm
16
-
-
Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plgs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm.
32
-
-
Providing and fixing precoated galvanised steel sheet roofing
accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating
120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7
-
-
-
GUTTER
83.8
-
-
Ridges plain (500 - 600mm)
35.4
-
-
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
1876.61
-
-
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by
table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 MM thick C.c. paver block of M-35 grade with approved colour design and pattern.
754.61
-
-
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
5000
-
-
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
139
-
-
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of
the cover to be not less than 58 kg
2
-
-
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying
the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and
the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @ 0.70 kg per sqm
22
-
-
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
200 mm nominal size dia
25
-
-
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
2
-
-
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
200 mm dia
2
-
-
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
200 mm clamp
2
-
-
Supplying and stacking at site dump manure from approved source,
including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 20 mm
6.76
-
-
Providing and displaying of Aglaonema Butterfly having ht.30 cm 10 to 12
fresh, healthy and attractive colorful leaves, well developed in 25 cm size
Earthen pot/Plastic pot & as per direction of the officer-in-charge.
20
-
-
Providing and displaying of Aglaonema Ice ht.25 cm having 10 to 12 fresh,
healthy and attractive colorful leaves, well developed in 25 cm size Earthen
pot/Plastic pot & as per direction of the officer-in-charge.
20
-
-
Providing and displaying of Aglaonema Parrot Jungle (three in one), having
ht. 30 cm and above with 20 to 25 leaves, well developed, fresh & healthy
in 25 cm size of Earthen pot/Plastic pot & as per direction of the officerin-
charge.
20
-
-
Providing and Displaying Allyssum white in full bloom well developed fresh
& healthy Plant in 20 cm Earthen Pot/Plastic Pot and as per direction
of the officer-in-charge.
20
-
-
Providing and Displaying Anemone hybrid (3 in one) variety well developed
with fresh & healthy Flower in full bloom in 25 cm Earthen Pot/Plastic Pot
and as per direction of the officer-in-charge.
20
-
-
Providing and Displaying Antirrhinum Hybrid Dwarf variety (3 in one) well developed with fresh & healthy Flower multi branch in full bloom in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
20
-
-
Providing and Displaying Acalypha Different colour well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size ofEarthen Pot/ Plastic Pot bushy as per direction of the officer-in-charge.
20
-
-
Providing and Displaying Acalypha green well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size Earthen Pot/Plastic Pot bushy as per direction of the officer-in-charge.
20
-
-
Providing and Displaying Acalypha red well developed with fresh & healthy 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge.
20
-
-
Solar LED Street Light( 30W LED) with 3 day backup: A LED based solar street lighting system consisting of PV modules, electronics ,lead acid battery, and LED based luminaries all suitably mounted on a 6.0m tubular pole above ground , base plate etc as required included. The battery is charged by electricty generated through the PV module panel (180 i.e 90x2 )during day time and the luminaries provides light from dusk to dawn. Specification of of solar LED Standalone street Light: Poly crystalline silicon solar panels, High lumen LED for max. efficiency with lifetime 50,000 hrs CRI nominal 70. Pressure die cast aluminium IP66 enclosure. Controller to charge batteries & microcontroller for autonomously determination of sunrise & sunset. Specific deep discharge batteries are used to store the energy. Metal battery box to be fitted at 3.0m height (Modle-Havells- LHSTABU7AAIF04/ Bajaj/Philips/Orient)
2
-
-
Main Panel - Supplying, designing, manufacturing, installation, testing, fitting, fixing and commissioning in correct alignment position, effecting proper connection of all incomers and outgoing of main panel of 14 SWG CRCA Sheet (2mm) steel IP-54 floor mounting cubical type LT Panel suitable for operation on 415V, 50Hz, 3Ph, AC supply and fault level 35kA. Approximate size (Shall be given at the time of work order ) with front operated construction including separate fabrication arrangement for fixing of switchgears and meters. The sheet steel undergo minimum seven tanks treatment followed by finishing powder coating of minimum 60 microns thickness duly compartmentalized with locking arrangement duly fixed on base channel size 100mm X 75mm X 6mm having accessories mounted inside cubicle panel, earthing with 2 Nos. of earth studs. : Incomer
4 pole, 160A, MCCB, BC-36 KA, 415V, 50 Hz, with fixed thermal release trip unit( for J.S.E.B. SUPPLY)-make- ABB/Legrand/ Schnider/C&S/L&T/Hager
Spreader terminals
4 pole, 32A, MCCB, BC-25 KA, 415V, 50 Hz with fixed thermal release trip unit ( for D.G. SUPPLY)
40A, 4 pole change over switch
Phase indication LED lamp R/Y/B
ON/OFF/TRIP indication
Digital Am-meter, three phase with selector switch 6A
Digital Volt-meter, three phase with selector switch, 6A
CT, ID:45mm. CLASS-1
10A HRC fuse for control supply Outgoings
1 no-4 pole, 100A, MCCB, BC35 kA, 415V, 50 Hz -for fish market building.
3 nos -4 pole, 63A, MCCB, BC25 kA, 220V, 50 Hz -for feeder pillar
2 nos -2 pole, 63A, MCB, BC10 kA, 220V, 50 Hz Enclosure- Enclosure to be fabricated out of CRCA steel sheet, 16 SWG sheet thickness, with 7 tank treatment powder coated paint, paint shed Siemens gray( RL -7032) , floor mounted cubical type as per required size.
Al. Bus bar of continious rating 200A for main supply
Al. Bus bar of continious rating 100A for DG supply
Mechanical items:-Nuts, bolts, washers doorlock etc
Electrical Items: Cu wirees & cables , sleeves, insulator, cable tie, wires, terminal etc +labour charges etc
1
-
-
Add 18 % GST (in Basic Rate must fill 12)
18
-
-
Add 1% Labour Cess (in Basic Rate must fill 1)
1
-
-