Building Construction Department Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 65,000Document Cost
₹ 5,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BCD_93752_1Tender No
BCD/EE/HAZARIBAG/ 22/02 /2024-25Tender Authority
Building Construction Department ViewPurchaser Address
-Website
http://jharkhandtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying, fitting and fixing 20 guage G.C.I, sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l.
45.14
-
-
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing rust, dirt, scales, smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. ( Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification)
220.36
-
-
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/l.
195.41
-
-
Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l.
37.38
-
-
Providing and laying 60mm thick faciory made cement concrete
interlocking paver block of M -30 grade made by block making
machine with strong vibratory compaction, of approved size, design
& shape, laid in required colour and pattern over and including 50mm
thick compacted bed of coarse sand, filling the joints with line sand
etc. all complete as per the direction of Engineer-in-charge.
122.68
-
-
Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .
659.33
-
-
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical andchemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :
450.31
-
-
Providing P.C.C.M - 200 with nominal mix of (1:1.5:3) in foundation with approved quality of stone chips 20 mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l.
21.61
-
-
Dismantling old plaster and pointing in cement or lime and raking out joints to 15 mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/l.
985.93
-
-
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
692.1
-
-
Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
312.73
-
-
Providing 150 mm. wide brick drain in cement mortar (1:6) with av. 125 mm. clear depth and 250 mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l.
100
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including jointing with seal ring conforming
to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed 110 mm diameter.
20
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain water pipes conforming to
IS : 13592 Type A, including jointing with seal ring conforming to IS :
5382, leaving 10 mm gap for thermal expansion 12.42.4 Single tee without door
4
-
-
Electrification-Point wiring in PVC conduit, with Modular type swtich:- Wiring for point /fan point /exhaust fan point /call point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with piano type switch ,phenolic laminated sheet, suitable size PVC/G.I. box etc.as Group B
15
-
-
power plug wiring in PVC conduit(2x4sq.mm):-wiringfor light power with 2x4 sq mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit along with 1 Nos. 4 sq. mm FR PVC insulated copper conductor singl core cable for loop earthing as requied.
9
-
-
S/F Piano type switch/socket:- Supplying and fixing following piano type switch/sockit on the existing switch box/cover including connections etc as required. 5/6amps,one way switch + 3 pin 5/6amps, socket
20
-
-
Circuit/submain wiring in PVC conduit:- Wiring for circuit/submain wiring along with earth with following sizeg PVCinsulated copper conductor,single core cable in surface/recessed PVC conduit as requied.2x1.5sq.mm+1x1.5sq.mm earth wire
800
-
-
2x2.5sq.mm+1x2.5sq.mm earth wire
800
-
-
4x6.0sq.mm+2x6.0sq.mm earth wire
50
-
-
S/F Modular type electronic Fan Regulator
15
-
-
S/F power plug point with Modular type accessories :-supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 6 pin 15/16 mps socket outlet and 15/16 mps piano type switch connection, painting etc. as required.
10
-
-
S/F ceiling roase:- suppliying and fixing 2 pin mps. Ceiling roase on the existing juction box/woon bolck including connection etc. as required
6
-
-
S/F batten holder:- supplying and fixing batten/ angle holder incuding connection etc as required
6
-
-
Supplying of 48' celling Fan as required.
15
-
-
ITC ceiling fan:- Installtion, testing and sonnissoning of ceiling, including wiring the down rods of standard length (op to 30cm) with 1.5 sq.mm FR PVC insulated. Copper conducotr, single core cable etc. as required.
2
-
-
S/F TPN. MCB DB:supplying and fixing following way three pole neutral sheet,MCBdistribution board,415 volts,on surface/recess,completewith tinned copper busbar,neutral busbar,earth bar,din bar, detachable gland plate,interconnection,phosphatized and powder painted including earthing etc asrequierd.(But without MCB/RCCB/lsolator) 6way,single door
2
-
-
S/F 'C' series, S.P. MCB:-Supplying and fixing 6amps to 32ampsrating,240 volts,'B' series,miniature circuut breaker suitable for lighting and other loads for following poles in the existing MCB DB complete with connections,testing and commissioning etc.asrequied.6/32amps,single pole, ''B'' series
2
-
-
S/F Four Pole MCB isolator:- Supplying and fixing following rating, double pole, 415 volts, isolator in the existing MCB DB complete with connection,testing and commissioning etc.as requied. 40amps
2
-
-
15/16 Watt LED Bulb
20
-
-
2x20 watt tubelight
10
-
-
90/100 W LED Street light
2
-
-
Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
6.72
-
-
Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
1.27
-
-
Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
8.16
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
0.86
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
1.37
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
3.7
-
-
Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
0.08
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
0.48
-
-
providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. a) 8 mm
0.22
-
-
b)10 mm
0.22
-
-
c) 12 mm
0.29
-
-
Centering and shuttering including strutting, propping etc. and removal of form forCOLUMNS footing=2*4*(4.5+4)*1.0
6.3
-
-
COLUMNS in S/S
24.66
-
-
E/w in excavation in foundation trenches in hard soil (vide classification of soil item B) and disposal to a distance up to 50 m including all lifts, leveling, ramming the foundation trenches removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I.
10.34
-
-
Centering and Shuttering includingg Struting,Propping etc. and removal of form for- Plinth Beam, Lintels band.Tie beam shuttering Lintal band shuttering
3.84
-
-
Providing two coats Ready Mixed Painting over steel Surface do----do all comp job.Same as item no 18
24.95
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)qty same as plaster area vide item no.14
18.9
-
-
Carriage of Materials(A) Sand Avg. Lead 5 km
27.98
-
-
(B) Chips Avg. Lead 15 km
18.89
-
-
(C) Metel Avg. Lead 15 km
2.9
-
-
(D) Bricks Avg. Lead 15 km
7.27
-
-
Add GST 18 %
0.18
-
-
Add L.Cess 1 %
0.01
-
-
Evaluation Notes How It Works ?