Building Construction Department Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Building Construction Department Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date10 Sep 2024
Closing Date18 Sep 2024
Tender Amount₹ 85,58,805 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. pre - Lamineted partical board with decorative lamination on both side.

63.87

-

-

... More
Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.

0.68

-

-

... More
Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.

13.5

-

-

... More
Taking down chaukhats in Windows including stacking serviceable materials within 15M. Lead and disposal of unserviceable materials with all leads all complete ap per direction of E/I.

8

-

-

... More
Dismantling lime terracing upto avg. 115mm depth with chisel and hammer including stacking servieable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all comlete as per direction of E/I.

249.17

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

0.46

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

1036.99

-

-

... More
Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.

162.86

-

-

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.

162.86

-

-

... More
providing designation 75 B brickwork in C M (1 :6 ) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing. taxes and royalty all complete as per building specification and direction of E/l.Providing designation 75 B brick work in C.M.(1:6) in superstructure.

7.45

-

-

... More
Providing designation 125mm thick reinforced designation 75A brick work in CM (1 : 4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15 mm depth, curing, taxes and royalty (but excluding the cost of reinforcement ) all complete as per building specifcation and direction of E/I

14.31

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal

7.03

-

-

... More
providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}

0.26

-

-

... More
providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.

-

-

-

... More
(a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}

0.16

-

-

... More
(b) 12 - 20mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)})

0.11

-

-

... More
Centering and shuttering including struting, propping etc and removal of form for Suspended floors, roof , landings , balconies and access platform

2.39

-

-

... More
Suspended floors, roof , landings , balconies and access platform

38.89

-

-

... More
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.

32.57

-

-

... More
Providing 19mm thick proof cement plaster (1: 3 ) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building spacification and direction of E/I.

57.67

-

-

... More
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.

16.42

-

-

... More
Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm. Depth, watering and disposal of unserviceable materials with all leads all complete as per diretion of E/I.

106.66

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

615.39

-

-

... More
Providing two coats of plastic emulsion paint of approved shade and make over old surface including washing cleaning and preparring the walls, scaffolding, washing of floor and taxes all complete as per building spacification and direction of E/I.

327.06

-

-

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

115.33

-

-

... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed vitrified floor tiles polished finish of size. Size of Tile 600 x 600 mm

135.52

-

-

... More
Providing and fixing granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab over 0.50 SQM

38.9

-

-

... More
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1 :4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile

39.87

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.WASHROOM

3.35

-

-

... More
Providing and laying 1st quality Ceramic glazed wall tiles thickness to be specified by the manufacturer) in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I.

177.21

-

-

... More
Water proofrng for Old and New Roof Slab :- Providing and laying water prooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofi ng coating as per manufacturer specification-With following steps :-

-

-

-

... More
(a)surface preparation :-Provrding and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd.

-

-

-

... More
/ MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.

-

-

-

... More
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat For the purpose of measurernent tte entire treated surface will be measured."

-

-

-

... More
(c) :2nd Coat:- To apply the 2nd coat of two component acrylic modified,ready to-use, flexible cementitious material right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." Alter three days of drying the 2nd coal , the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification lo be done as per satisfation of E/c.

-

-

-

... More
The Watqrproofing Brand:*Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A.Acrylic copol;,mer, Part 13 Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +270C Tensile Strength -2 N/mm2 after 28 Days (with Fibre cloth) (According to ASTM D 2370)Pullout Bond Strenth-2 n/mm2 (concrete failure) (According to ISO.

-

-

-

... More
4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Cloth (According to ASTM D 2370)

-

-

-

... More
D Protection of treated with pcc :- The treated surface shourd be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( 1:120) towards the rain outlets in alternatepanels of 2 mtx2mt keeping 6 mm gap between the panel joint. integral water proofing admixture conforming to lS 2645 @ of 100 ml perbag of of cement to be added in the screed concrete (paid separately for thts ltems

-

-

-

... More
all corners shall be charfered with 150mm X 150 mm fillet. The rain water outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose of measurement the entire treated surface will be measured."

-

-

-

... More
(e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc

269.76

-

-

... More
Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) raintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr

269.76

-

-

... More
Provrding and filling of Groove between 25 mm PCC Panels with Polyshlphide Sealant (Poring Grade)as per drawings and technical specifications and dii-ection of E in Charge (with 1B% GST).Brand:-Sika- Polysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent

269.76

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter

125

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° 110 mm bend

20

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe

22

-

-

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm

18

-

-

... More
CARRIAGE

-

-

-

... More
Brick

3.76

-

-

... More
Sand

4.83

-

-

... More
Chips

0.59

-

-

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore

2

-

-

... More
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.

1

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 18.53.1 15mm nominal bore

2

-

-

... More
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.15 mm nominal bore, weighing not less than 32 gms

2

-

-

... More
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia

1

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

1

-

-

... More
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern

1

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the wallswherever require:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap

1

-

-

... More
Providing and fixing PTMT grating of approved quality and colour.125 mm nominal dia with 25 mm waste hole

4

-

-

... More
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15 mm nominal bore with 45 cm length

2

-

-

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia

8

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.Concealed work, including cutting chases and making good the walls etc..15 mm nominal dia Pipes

75

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.Concealed work, including cutting chases and making good the walls etc..20 mm nominal dia Pipes

50

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.25 mm nominal dia Pipes

100

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc32 mm nominal dia Pipes

50

-

-

... More
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominalsize), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

-

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.

1

-

-

... More
Polythene water storage tank of ISI mark (eg sintex/sinter/himgiri/gangotri ) with cover & locking system

1000

-

-

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

2

-

-

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :510x1040 mm bowl depth 178 mm

2

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.110 mm diameter

30

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.75 mm diameter

30

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
75 mm Coupler

5

-

-

... More
110 mm Coupler

8

-

-

... More
75mm single pushfit coupler

7

-

-

... More
110mm single pushfit coupler

5

-

-

... More
75 mm single tee with door

7

-

-

... More
110mm single tee with door

4

-

-

... More
75 mm single tee without door

4

-

-

... More
110 mm single tee without door

7

-

-

... More
75mm bend 87.5

7

-

-

... More
110mm bend 87.5

5

-

-

... More
75mm shoe (plain )

6

-

-

... More
110mm shoe (plain )

5

-

-

... More
Underground Sump (4000 L)

1

-

-

... More
Point wiring in PVC conduit, with modular typeswitch:Wiring for light poinVfan poinUexhaust fan point/call bell point v/ith 1.5sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, with modular sw'itch, modular plate suitable GI box etc as required.Group C

40

-

-

... More
S/F light plug point with modular type accessories :Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch. corutection, painting etc. as required (For light plugs to be used in non residential buildings)

4

-

-

... More
S/F power plug point with modular type accessories :Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fxing 6 pin 15/16 amps modular socket outlet and l5/16 amps modular switch. connection, painting etc. as required (For light plugs to be used in non residential buildings)

2

-

-

... More
Power plug widng in PVC conduit (2 x 4 sq. nun) :-Wiriug for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.nrm FR PVC insulated copper conductor single core cable for loopcarthing etc as required.

26

-

-

... More
Power plug widng in PVC conduit (2 x 4 sq. nun) :-Wiriug for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.nrm FR PVC insulated copper conductor single core cable for loopcarthing etc as required.2x1.5 sq.urm+ 1x 1.5 sq.mm earthwire

26

-

-

... More
Power plug widng in PVC conduit (2 x 4 sq. nun) :-Wiriug for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.nrm FR PVC insulated copper conductor single core cable for loopcarthing etc as required 2 x2.5 sq.mm + I x2.5 sq.mm earth wire

26

-

-

... More
Power plug widng in PVC conduit (2 x 4 sq. nun) :-Wiriug for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.nrm FR PVC insulated copper conductor single core cable for loopcarthing etc as required2 x l0 sq.mm+ I x6 sq.mm earthwire

26

-

-

... More
Circuit/ submain wiring in PVC conduit :- Wiring for circuit/ submain wiring along with earh wire with the following sizes of FR PVC insulated copper conductor single core cable in surface /recessed PVC conduit as required4 x 6.0 sq.mm +2x6.0sq.mm earthwire

26

-

-

... More
Wirilg in cxisting conduit :-supplying and drawing following sizes of FR PVC insulated copper conductor single core cable in existing surface / recessed steel / PVC conduit including dismantling as required.2x4 sq mm

26

-

-

... More
Wiring in cxisting conduit :-supplying and drawing following sizes of FR PVC insulated copper conductor single core cable in existing surface / recessed steel / PVC conduit including dismantling as required 40 amps

4

-

-

... More
Wiring in cxisting conduit :-supplying and drawing following sizes of FR PVC insulated copper conductor single core cable in existing surface / recessed steel / PVC conduit including dismantling as required80/100 amps

4

-

-

... More
S/F S.P. MCB DB :- Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, compiete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door

2

-

-

... More
S/F S.P. MCB DB :- Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, compiete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).4 way (4 + 12), Dorrble door, Horizontal type

2

-

-

... More
S/F S.P. MCB DB :- Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, compiete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator6way (4 + 18), Double door, Horizontal type

2

-

-

... More
S/F S.P. MCB :-Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 kA, "C" curve,miniature circuit breaker suitable for.inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required.6/32 amps, Single pole

2

-

-

... More
S/F S.P. MCB :-Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 kA, "C" curve,miniature circuit breaker suitable for.inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required40 amps, TPN

2

-

-

... More
S/F S.P. MCB :-Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 kA, "C" curve,miniature circuit breaker suitable for.inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required2.12.6 40 amps, DP

2

-

-

... More
S/F S.P. MCB :-Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 kA, "C" curve,miniature circuit breaker suitable for.inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required50/63 amps, DP

2

-

-

... More
S/F ceiling rose :-supplying and fxing 2 pin 5 amp. Ceiling rose on the existing junction box/wooen block including connection etc. as required

30

-

-

... More
ITC fluorescent fitting directly on surface :- Installation testing and commissioning of pre-wired, fluorescent fitting ./ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly / wall. including connection with 1.5 aq.mm FR PVC insulated . copper conductor single core cable and earthing etc. as required.

12

-

-

... More
ITC fluorescent fitting with down rods:- Installation testing and commissioning of pre-wired, fluorescent fitting.compact fluorescent fitting of all types, complete with all accessories and tube etc. including supplyrng and fixing ball and socket arrangement 2 no. down rods of 20mm dia x 1.6 mm thick steel conduit/Gl pipe upto 30 cm length. , painting and wiring the down and connection with 1.5 sq.mm PVC insulated, copper conductor, single core cable and earthing etc. as required

12

-

-

... More
ITC ceiling fan:-Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required.

12

-

-

... More
S/F Piaoo type switch/ socket :- Supplying and fxing of following piano type switch / socket on the existing switch box / cover including connections etc. as required.5/6 amps, one way switch

2

-

-

... More
S/F Piaoo type switch/ socket :- Supplying and fxing of following piano type switch / socket on the existing switch box / cover including connections etc. as required3pin 5/6 amps, socket outlet

2

-

-

... More
S/F Piaoo type switch/ socket :- lSupptyrng and fxing of following piano type switch / socket on the existing switch box / cover including connections etc. as requted.Electronic step fan regulator, mini

12

-

-

... More
S/F PVC/G.I. boxes :-Supplying and fixing of following sizes of PVC/G.I box on surface / recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.75 mm x 75mm x 50mm deep/ (4" x 4")

4

-

-

... More
S/F PVC conduit :Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.20mm

26

-

-

... More
S/F Batten holder :-supplying and fixing Batten / Angle holder including connection etc as required.

8

-

-

... More
P/F G.I. lightning condutor final :- Providing and fixing of lighting conductor finial , made of 25mm dia 300mm long , G.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate including holes etc. complete as required.

1

-

-

... More
P/f G.I. lightning conductor tape in horizontal Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required.( for Horizontal run ).

30

-

-

... More
P/F G.I. lightning conductor tape in vertical Providing and fxing G.I. tape 20mm x 3rrm thick on parapet or surface of wall for lightning conductor complete as required.( for Vertical run )

30

-

-

... More
MV cable :- supply of ISI marked aluminium cable conductor XLPE PVC insulated cable as per IS : 7098 armoured, served shealthed 1100V grade with termination and laying of cable make :- finolex, polycab, Havells universal- 50 sqmm X 3.5 Core armoured AL Cable for SEB supply

30

-

-

... More
MV cable upto 120 sqm in ground without sand cover Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 185 sq mm but not exceeding 400 sq. mm in the existing RCC/HUME/STONEWAREA4ETAL pipe as required.

30

-

-

... More
Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to13:374,.2019 including wiring the down rods of standard length (upto 30cm) with l.Ssq.mm. FR PVC insulated, copper wire suitable for 230V 50H2, single phase supply etc. complete as required.make polar/bajaj/havells/philips.1400mm (56") Ceiling Fan

12

-

-

... More
S.I.T.C of floowing rating surface mounted LED tube light fitting suitable for 230V 50H2, single phase supply etc. complete as required.20122W LED Tube light

20

-

-

... More
LED bulb 9W/10W:- supplying and fixing of LED 9W/10W bilb and acessories as required make :- Bajaj/havells/ phillips.

8

-

-

... More
S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existingpole/pipe for supply voltage 1C[.Z70Y AC,50Hz. Luminarie shall be confirm tolS:,1,0322part-5/section-5 and shall be complete with all neccssary accessories as required.90/100W LED Flood light

3

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required..0.63 MM (24 gauge) Galvanized Sheet Steel

35

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required..0.8 MM (22 gauge) Galvanized Sheet Steel

35

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.1.0 MM (20 gauge) Galvanized Sheet Steel

95

-

-

... More
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.DAMPER

1

-

-

... More
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Actuator

2

-

-

... More
Supply, installation, testing and commissioning of modular OT Wall and corner panels with insulated prefabricated puff Panels. The OT wall shall be constructed using GI puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of

-

-

-

... More
80 mm thickness are firmly bonded together by sprayed -in insulating foam, which hardens during the process. The core consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3. The thickness of Puff shall be minimum 40 mm. The sheet panel shall be of indigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mmlong SS fasteners which shall be fully threaded and power drilled

-

-

-

... More
The Panels of walls and ceilingshall be tied together by suitable SS coving. The individual wall panels of wall and ceiling shall be tied together by suitable SS coving. The individual wall panels shall be welded together bySS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of equipment’s. This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap

-

-

-

... More
All wall-mounted equipment shall be flush mounted and sealed in operation theatre. All the sharp edges and corners shall be in radius to avoid bacterialcontamination. The wall panel design shall be such that it enables the installation and supports all equipment’s. Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wall-mounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. Thework should be executed as per the directions of Engineer–in-Charge.

12.36

-

-

... More
Supply, installation, testing and commissioning of modular OT Wall and corner panels with insulated prefabricated puff Panels. The OT wall shall be constructed using GI puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of

-

-

-

... More
The thickness of Puff shall be minimum 40 mm. The sheet panel shall be ofindigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mm long SS fasteners which shall be fully threaded and power drilled. The Panels of walls and ceiling shall be tied together by suitable SS coving. The individual panels of wall and ceiling shall be tied together by suitable SS coving.

-

-

-

... More
The individual wall panels shall be welded together bySS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of equipment’s. This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap. All wall-mounted equipment shall be flush mounted and sealed in operation theatre

-

-

-

... More
All the sharp edges and corners shall be in radius to avoid bacterial contamination. The wall panel design shall be such that it enables the installation and supports all equipment’s. Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wallmounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. The work should be executed as per thedirections of Engineer–in-Charge.

151.71

-

-

... More
Supply, installation, testing and commissioning of modular OT ceiling panels with insulated prefabricated puff Panels. The OT ceiling shall be constructed using GI puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of 0.80 mm thickness are firmly bonded together by sprayed -in insulating foam, which hardens during the process. The core consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3.

-

-

-

... More
The thickness of Puff shall be minimum 40 mm. The sheet panel shall be ofindigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mm long SS fasteners which shall be fully threaded and power drilled. The Panels of walls and ceiling shall be tied together by suitable SS coving. The individual panels of wall and ceiling shall be tied together by suitable SS coving.

-

-

-

... More
The individual wall panels shall be welded together bySS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of equipment’s. This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap. All wall-mounted equipment shall be flush mounted and sealed in operation theatre

-

-

-

... More
All the sharp edges and corners shall be in radius to avoid bacterial contamination. The wall panel design shall be such that it enables the installation and supports all equipment’s. Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wallmounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. The work should be executed as per thedirections of Engineer–in-Charge.

55.37

-

-

... More
Providing Epoxy flooring self leveling type on strong base in desired colour/design as approved by Engineer-in-Charge. Resin for epoxy is to be of floor grade type i/c appropriate hardner and filler material. with 5 year defect liability period.3 mm thick

58

-

-

... More
Hermetically Sealed Sliding Door System: Fabrication, Supply, installation, testing & commissioning of sliding type Hermetically Sealed door having high density particle board cores/ CFC free Polyurethane, high pressure laminate face on both sides, viewing window 300 x 300mm. Size: 1500 x 2100 mm (W x H) as per direction of EIC. Automatic Doors: Provided with Radar Switch - 2 Nos., Foot Switch - 2 Nos. and Photocell Sensors. Automatic Door (1500 mm x 2100 mm) Approved makes - Metaflex /REBBON / MDD Engineering/ Altos / Dormed/ Meditech

1

-

-

... More
Revolving Chair With Arm Synchronic tilt mechanism (GODREJ INTERIO ACE FULL BACK CHAIR) (Product id: 5116877-70887346890)

9

-

-

... More
OCEAN LIFE SCIENCE CORPORATION Laboratory Steel Furniture Side bench with rack and table top OCEAN LIFE SCIENCE CORPORATIONR (OLSC-IWB)

1

-

-

... More
BETCO Laboratory Steel Furniture Island bench with table top BETCOR (BETCO-LB-202)

2

-

-

... More
Supplying, installation, testing & commissioning of Effluent Treatment Plant for the following duty:

-

-

-

... More
Nature of waste water - Lab effluent

-

-

-

... More
Daily Avg. Flow = 2 cum/Day

-

-

-

... More
Reuse of ETP treated water after treatment. Horticulture, Landscaping, irrigation etc.

-

-

-

... More
Influent Characteristics (considered)

-

-

-

... More
pH - 6.5-8.0

-

-

-

... More
BOD5 - 200-250 mg/liter

-

-

-

... More
S. Solids - 250-300 mg/liter

-

-

-

... More
COD - 400- 600 mg/liter

-

-

-

... More
Oil & Grease ` - 50 mg/liter

-

-

-

... More
Effluent discharge standard after treatment:

-

-

-

... More
pH - 6.5 - 8.0

-

-

-

... More
BOD5 - Less than 30 mg/liter

-

-

-

... More
S. Solids - Less than 50 mg/liter

-

-

-

... More
COD - Less than 100 mg/liter

-

-

-

... More
Oil & Grease - 5 mg/lt

-

-

-

... More
Supply, installation, testing & commissioning of Screens

-

-

-

... More
Mild Steel Suitable Sized Manually operated Bar Screen as per following specifications

-

-

-

... More
Cleaning :- Manual Screen

-

-

-

... More
MOC :- MS

-

-

-

... More
Supply, installation, testing & commissioning of Raw effluent lifting pumps complete with all accessories, motor of required capacity. Pumps shall have following duty:

-

-

-

... More
Flow rate (each) = 0.25 m3/hr

-

-

-

... More
Head = 8-10 m

-

-

-

... More
Make = Kirloskar/Wilo/Eqv.

-

-

-

... More
Supply, installation testing and commisioning of physico-chemical treatment, the system shall be comprising of dosing pump, dosing tank, and Agitators.

-

-

-

... More
Dosing Units

-

-

-

... More
Alum Dosing system

-

-

-

... More
Poly Dosing System

-

-

-

... More
Lime Dosing System

-

-

-

... More
Tube deck media in settling tank

-

-

-

... More
Providing and fixing all interconnecting plant piping of required MOC as MS/UPVC and isolation control valves for making the piping arrangement complete within the battery limits.

-

-

-

... More
Supply, installation, testing & commissioning of SBR feed Pumps with CI casing & CI impeller complete with all accessories, motor of required capacity. The pumps shall be complete with all accessories. Pumps shall have following duty:

-

-

-

... More
Flow rate (each) = 0.25m³/hr

-

-

-

... More
Head = 8-10 m

-

-

-

... More
Make = WILO/Kirloskar/Eqv.

-

-

-

... More
Supply, installation, testing & commissioning of SBR Based Biological system comprising of the following equipments:

-

-

-

... More
Air Blowers For SBR tanks

-

-

-

... More
Capacity :Apprx. 5-10 m3/hr. @5000-5500 mmwg

-

-

-

... More
Type Twin Lobe

-

-

-

... More
Fine Bubble Diffusers

-

-

-

... More
Qty: 1 Lot

-

-

-

... More
Decanter

-

-

-

... More
Make: PS aqua/ Grannus Water and Env. Solution Pvt. Ltd.

-

-

-

... More
Pipes and fittings for Air piping and Air Grid

-

-

-

... More
Supplying, installing, testing, commissioning of Centrifugal Horizontal Filter Feed pumps Complete in CI body & CI impeller with motor, and all other accessories required to complete the system.

-

-

-

... More
Pumps = 02 Nos.(1w + 1s)

-

-

-

... More
Flow rate (each) = 0.25 m³/hr

-

-

-

... More
Head = 25 - 30 m

-

-

-

... More
Make - Kirloskar/Eqv

-

-

-

... More
Supply, installation, testing & commissioning of Sludge transfer/feed pumps for sludge transfer to SHT complete with all the accessories, motor of required capacity. The pumps shall be complete with Base frame, Delivery header with pressure gauge on delivery line.

-

-

-

... More
Flow rate (each) = 0.5/1.0 m³/hr

-

-

-

... More
Head = 8-10 m

-

-

-

... More
Make - Kirloskar/Eqv

-

-

-

... More
Supplying, Installation, testing and commissioning of Chemical dosing system comprising of Sintex Tank with inlet/ outlet connection, piping and valves along with metering pump for dosing.

-

-

-

... More
Supplying, installing, testing, commissioning of Sludge Bag System of suitable size for the dewatering of sludge generated per day.

-

-

-

... More
Make: Grannus Water and Env.Solution Pvt. Ltd.

-

-

-

... More
Mode of operation: Manual

-

-

-

... More
Supplying, installation, testing & commissioning of FRP vessel filter with frontal piping and Valves with all the required accessories. Filter shall include media, standard fittings like pressure gauges, sampling cock, rinse drain.

-

-

-

... More
Dual Media Filter

-

-

-

... More
Dia : 150 mm

-

-

-

... More
HOS: 1100

-

-

-

... More
Filter media: Fine and coarse sand, pebbles and gravels

-

-

-

... More
Make: PS aqua/ Grannus Water and Env.Solution Pvt. Ltd.

-

-

-

... More
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre fabricated out of 14 gauge CRCA sheet steel. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthling terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Panel should be complete with Isolation push button for every equipment and auto manual selection switches . Make: GWESPL/Eqv

-

-

-

... More
Total cost for above work (A) ( In Rs.)

1

-

-

... More
Tanks

-

-

-

... More
Supply, installation. Testing and commissioning of following Tanks In MSEP/HDPE

-

-

-

... More
Flash Mixer

-

-

-

... More
Flocculation tank

-

-

-

... More
Settling Tank

-

-

-

... More
Break Tank

-

-

-

... More
SBR Tank

-

-

-

... More
Intermediate Water Tank

1

-

-

... More
Double Skinned Floor Mounted Air Handling Units with Pre & Fine Filter

-

-

-

... More
Supply, installation, testing and commissioning of factory fabricated Double Skinned Air- handling unit celing Suspended type / Floor Mounted Factory fabricated out of extruded aluminium section consisting with 0.8 mm pre-plasticized/pre-coated Galvanised steel sheet outside & 0.8 mm plain alvanised steel sheet with 40 mm thick injected PUF of density not less than 38 Kg/CuM. 6 Row cooling coil made of Aluminium finned Copper tube ( thickness 0.50 mm) with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% (MERV 8), & Fine- filter section with non woven synthetic media of 3 micron particle size with an efficiency of 95% (MERV 13), section with multirows 6 Row deep DX cooling / heating coil of copper tube & aluminium fin construction, Motor fan section complete with floor standing forward curved DIDW centrifugal fan, squirrel cage induction motor, belt drive package, sanwitch Insulated stainless steel drain pan and vibration isolation pads all complete as per specifications. AHUs shall be selected for a maximum face velocity of 500 FPM. The units shall be compatible with VRF outdoor units. The unit shall be supplied with inbuilt DOL starter for motor, electronic expansion valve/s (Dx), thermostats, control wiring & all accessories as required for completing installation. Fan outlet velocity shall not exceed 1653 FPM (8.4 MPS).

-

-

-

... More
The face velocity across cooling coil shall be limited to 152 MPM maxm.The capacity of Air-handlers shall be as follows: Fan Outlet velocity Max 9.6 m/s

-

-

-

... More
(For AHU No. Please Refer Basic Of Design & AC Tender Drawing )

-

-

-

... More
AHU / LAB - 1 x 8.5 TR Air Cooled Condenser Outdoor Unit

1

-

-

... More
3000 CFM Supply Blower, 6 Row CC, 125 mm Static , Pressure

-

-

-

... More
for Supply Fan , 3500 CFM Ex. Blower , 75 mm Static Pressure

-

-

-

... More
for Exhaust fan )

-

-

-

... More
Supply Installation, testing & commissioning of Air Cooled Ductable Split Units. - Outdoor & Indoor unit shall connected with DX coil, refrigerant piping, firstcharge of refrigerant & oil, HP/LP cutout, thermostatic expansion valve, distributor, starter and other necessary controls to form a factory tested compact unit. The outdoor unit shall have condenser coil, fans with motor & drive, copleand scroll compressors, panel etc. The ductable units should be complete with programable microprocessor panel (BMS Compatible). ( Make: LG / Blue Star / Daikin)

-

-

-

... More
8.5 TR With Scroll Compessor

1

-

-

... More
Double Skinned Floor Ceiling Suspended Type Fan Filter Unit with Hepa Filter

-

-

-

... More
Supply, installation, testing and commissioning of factory fabricated Double Skinned Fan Filter Unit Celing Suspended type Fabricated out of extruded aluminium section consisting with 0.8 mm pre-plasticized/pre-coated Galvanised steel sheet outside & 0.8 mm plain alvanised steel sheet with 40 mm thick injected PUF of density not less than 38 Kg/CuM. Hepa - filter section with non woven synthetic media of 1 micron particle size with an efficiency of 99.99% (MERV 20) with Motor fan section complete with floor standing forward curved DIDW centrifugal fan, squirrel cage induction motor, belt drive package, As per specifications. AHUs shall be selected for a maximum face velocity of 200 FPM. & all accessories as required for completing installation. Fan outlet velocity shall not exceed 1653 FPM (8.4 MPS).

-

-

-

... More
FFU - 750 CFM with Hepa Filter, 40 MM of WC

1

-

-

... More
FFU - 850 CFM with Hepa Filter, 40 MM of WC

1

-

-

... More
DUCTING, GRILLS,DIFFUSER AND INSULATION

-

-

-

... More
Supply,installation and testing of powder coated aluminium extruded grills/diffusers as per specifications given in tender and of following sizes:

-

-

-

... More
Single Louvered supply / Return Air registers (Grill)

2

-

-

... More
Supply / return suare ceiling air terminals (diffusers)

1

-

-

... More
Fresh / Exhaust air louvers with bird screen & damper

1

-

-

... More
Flexible connection for AHU/FCU madeup of f/r fabric compelte with flange

2

-

-

... More
Supply,installation and testing of multiblade type GI Duct Damper for duct/collars to be provided with suitable links and quadrants for control of volume of air

3

-

-

... More
Supply and Application of Acoustic Insulation Inside the Duct with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents.conforming to standard specification. 15 mm thick open cell nitrile rubber.

10

-

-

... More
Supply & Installation of Thermal Insulation on Ducts not exposed to sunlight using Closed Cell Class O Nitrile Rubber Elastomeric Insulation of Density 40 - 60 Kg/m3, Thermal Conductivity of 0.037 W/mk at 20 Celcius Mean Temp. and µ≥7000 (without any additional vapour barrier) and with factory laminated aluminium foil of minimum 60 Microns thickness having weight of 193 gsm as per EN ISO 2286-2, tensile strength shall be 90N/15mm as per EN ISO 527-3 with elongation 10% as per EN ISO 527-3; to be applied on Ducts using manufacturer's recommended Rubber based Adhesive in a blend of Solvents.25 mm thick (Class O) Foil for Supply Air Duct

155

-

-

... More
MOTOR CONTROL CENTRE

1

-

-

... More
i) For 1 x 8.5TR Outdoor Unit

-

-

-

... More
Supply, installation, testing and commissioning of Cubical type sectinalised floor standing switch board of 31 MVA fault capacity at 415 V complete with 4 strip, 63 A capacity Aluminium Bus - Bar Electrolytic grade, cable alley, switchgears of following capacity & as per specifications.

-

-

-

... More
i) INCOMER

-

-

-

... More
01 Set - 63 A manually operated draw out type TPN MCCB with Overload, short ckt., earth fault, protection release, with 144 mm (0 - 63 A) ammeter protection release, with 144 mm (0 - 63 A) Voltmeter with selector switch, phase indication light with protection fuse, on / off / trip indicating light .

-

-

-

... More
OUTGOINGS

-

-

-

... More
i) For 01 Nos. Outdoor Unit

-

-

-

... More
01 No. - 63A TPN MCB with overload, protection with (0 - 40A) ammeter with three CT & selector switch, on / off / trip indication light with protection fuses.

-

-

-

... More
Controls & interlocking accessories as required. LOT

-

-

-

... More
Power Cabling (PVC insulated and PVC sheathed, armoured, Aluminium Conductor of 1.1 KV grade of following sizes.

-

-

-

... More
i) For Compressor 3.5C x 16 Sq. mm Aluminium Conductor

80

-

-

... More
ii) For Indoor Unit Blower & Compressor 3C x 4 Sq. mm Aluminium Conductor

70

-

-

... More
iii) For Condenser Fan2C x 1.5 Sq. mm Copper Conductor

90

-

-

... More
Control Cabling ( PVC insulated & PVC sheathed, armoured, Copper Conductor of 1.1 KV grade of following sizes. 6C x 1.5 Sq. mm Copper Conductor

90

-

-

... More
Supply & laying of 8 SWG GI wire.

20

-

-

... More
Add 18 % GST (in Basic Rate must fill 12)

18

-

-

... More
Add 1% Labour Cess (in Basic Rate must fill 1)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.