Building Construction Department Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Building Construction Department - BCD Tender
Eprocure
Opening Date24 Jun 2024
Closing Date29 Jun 2024
Tender AmountRefer Documents
Costs
EMD
0Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BCD_87156_1Bid Award Id
ViewTender No
BCD/Jamshedpur/06/2024-25Tender Authority
Building Construction Department ViewPurchaser Address
-Website
http://jharkhandtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply, installation, testing and commissioning of factory fabricated Double Skinned Air- handling unit celing Suspended type / Floor Mounted Factory fabricated out of extruded aluminium section consisting with 0.8 mm pre-plasticized/pre-coated Galvanised steel sheet outside & 0.8 mm plain alvanised steel sheet with 40 mm thick injected PUF of density not less than 38 Kg/CuM. 6 Row cooling coil made of Aluminium finned Copper tube ( thickness 0.50 mm) with coil section, pre - filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% (MERV 8), & Fine- filter section with non woven synthetic media of 3 micron particle size with an efficiency of 95% (MERV 13), section with multirows 6 Row deep DX cooling / heating coil of copper tube & aluminium fin construction, Motor fan section complete with floor standing forward curved DIDW centrifugal fan, squirrel cage induction motor, belt drive package, sanwitch Insulated stainless steel drain pan and vibration isolation pads all complete as per specifications. AHUs shall be selected for a maximum face velocity of 500 FPM. The units shall be compatible with VRF outdoor units. The unit shall be supplied with inbuilt DOL starter for motor, electronic expansion valve/s (Dx), thermostats, control wiring & all accessories as required for completing installation. Fan outlet velocity shall not exceed 1653 FPM (8.4 MPS).
1
-
-
The face velocity across cooling coil shall be limited to 152 MPM maxm.The capacity of
Air-handlers shall be as follows: Fan Outlet velocity Max 9.6 m/s
-
-
-
(For AHU No. Please Refer Basic Of Design & AC Tender Drawing )
-
-
-
AHU / LAB - 1 x 8.5 TR Air Cooled Condenser Outdoor Unit
-
-
-
3000 CFM Supply Blower, 6 Row CC, 125 mm Static , Pressure
-
-
-
for Supply Fan , 3500 CFM Ex. Blower , 75 mm Static Pressure
-
-
-
for Exhaust fan )
-
-
-
Supply Installation, testing & commissioning of Air Cooled Ductable Split Units. - Outdoor & Indoor unit shall connected with DX coil, refrigerant piping, firstcharge of refrigerant & oil, HP/LP cutout, thermostatic expansion valve, distributor, starter and other necessary controls to form a factory tested compact unit. The outdoor unit shall have condenser coil, fans with motor & drive, copleand scroll compressors, panel etc. The ductable units should be complete with programable microprocessor panel (BMS Compatible). ( Make: LG / Blue Star / Daikin)
-
-
-
8.5 TR With Scroll Compessor
1
-
-
Double Skinned Floor Ceiling Suspended Type Fan Filter Unit with Hepa Filter
-
-
-
Supply, installation, testing and commissioning of factory fabricated Double Skinned Fan Filter Unit Celing Suspended type Fabricated out of extruded aluminium section consisting with 0.8 mm pre-plasticized/pre-coated Galvanised steel sheet outside & 0.8 mm plain alvanised steel sheet with 40 mm thick injected PUF of density not less than 38 Kg/CuM. Hepa - filter section with non woven synthetic media of 1 micron particle size with an efficiency of 99.99% (MERV 20) with Motor fan section complete with floor standing forward curved DIDW centrifugal fan, squirrel cage induction motor, belt drive package, As per specifications. AHUs shall be selected for a maximum face velocity of 200 FPM. & all accessories as required for completing installation. Fan outlet velocity shall not exceed 1653 FPM (8.4 MPS).
-
-
-
FFU - 750 CFM with Hepa Filter, 40 MM of WC
2
-
-
FFU - 850 CFM with Hepa Filter, 40 MM of WC
2
-
-
Supply,installation and testing of powder coated aluminium extruded grills/diffusers as per
specifications given in tender and of following sizes:
-
-
-
Single Louvered supply / Return Air registers (Grill)
2
-
-
Supply / return suare ceiling air terminals (diffusers)
1
-
-
Fresh / Exhaust air louvers with bird screen & damper
1
-
-
Flexible connection for AHU/FCU madeup of f/r fabric compelte with flange
2
-
-
Supply,installation and testing of multiblade type GI Duct Damper for duct/collars to be provided with suitable links and quadrants for control of volume of air
3
-
-
Supply and Application of Acoustic Insulation Inside the Duct with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071- 05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents.conforming to standard specification.
-
-
-
15 mm thick open cell nitrile rubber.
10
-
-
Supply & Installation of Thermal Insulation on Ducts not exposed to sunlight using Closed Cell Class O Nitrile Rubber Elastomeric Insulation of Density 40 - 60 Kg/m3, Thermal Conductivity of 0.037 W/mk at 20 Celcius Mean Temp. and µ≥7000 (without any additional vapour barrier) and with factory laminated aluminium foil of minimum 60 Microns thickness having weight of 193 gsm as per EN ISO 2286-2, tensile strength shall be 90N/15mm as per EN ISO 527-3 with elongation 10% as per EN ISO 527-3; to be applied on Ducts using manufacturer's recommended Rubber based Adhesive in a blend of
Solvents.
-
-
-
25 mm thick (Class O) Foil for Supply Air Duct
140
-
-
MOTOR CONTROL CENTRE
1
-
-
i) For 1 x 8.5TR Outdoor Unit
-
-
-
Supply, installation, testing and commissioning of Cubical type sectinalised floor standing switch board of 31 MVA fault capacity at 415 V complete with 4 strip, 63 A capacity Aluminium Bus - Bar Electrolytic grade, cable alley, switchgears of following capacity & as per specifications.
-
-
-
Items
-
-
-
01 Set - 63 A manually operated draw out type TPN MCCB with Overload, short ckt., earth fault, protection release, with 144 mm (0 - 63 A) ammeter protection release, with 144 mm (0 - 63 A) Voltmeter with selector switch, phase indication light with protection fuse, on / off / trip indicating light .
-
-
-
OUTGOINGS
-
-
-
i) For 01 Nos. Outdoor Unit
-
-
-
01 No. - 63A TPN MCB with overload, protection with (0 - 40A) ammeter with three CT & selector switch, on / off / trip indication light with protection fuses.
-
-
-
Controls & interlocking accessories as required.
-
-
-
Power Cabling (PVC insulated and PVC sheathed, armoured, Aluminium Conductor of 1.1 KV grade of following sizes.
-
-
-
i) For Compressor
-
-
-
3.5C x 16 Sq. mm Aluminium Conductor
80
-
-
ii) For Indoor Unit Blower & Compressor
-
-
-
3C x 4 Sq. mm Aluminium Conductor
70
-
-
iii) For Condenser Fan
-
-
-
2C x 1.5 Sq. mm Copper Conductor
90
-
-
Control Cabling ( PVC insulated & PVC sheathed, armoured, Copper Conductor of 1.1
KV grade of following sizes.
-
-
-
6C x 1.5 Sq. mm Copper Conductor
90
-
-
Supply & laying of 8 SWG GI wire
20
-
-
Total
-
-
-
Add GST @ 18 % in total of above all items.
-
-
-
Total with GST
-
-
-
Add Labour Cess @1%
-
-
-
Grand Total =
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements