Building Construction Department Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Building Construction Department Tender

Works
Security and Emergency Services
Eprocure
Opening Date13 Jan 2025
Closing Date18 Jan 2025
Tender AmountRefer Documents 
Notes
Download

Summary

Proposed Expansion Of Surveillance System (cctv Installation Including Monitor) In The

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Fans- 2

-

-

-

... More
USB Port- 1 (type A, USB 2.0)

-

-

-

... More
Console- 1 (RS232 RJ45)

-

-

-

... More
IEEE 1588v2 capable ports- 12

-

-

-

... More
MACsec capable ports-12

-

-

-

... More
Operating temperature -10°C to 60°C (14°F to 140°F)

-

-

-

... More
Storage temperature - -40°C to 85°C (-40°F to 185°F)

-

-

-

... More
Humidity (operating & storage) - to 95% non-condensing

-

-

-

... More
Altitude-13,000 ft

-

-

-

... More
MTBF (Hours)- 1,298,328

-

-

-

... More
Power Supply efficiency-85%

-

-

-

... More
Acoustic (-10°C to 45°C) (dB)-Silent

-

-

-

... More
Acoustic (45°C to 60°C) (dB)-56 dBA

-

-

-

... More
System power consumption (idle)-8.5 W

-

-

-

... More
System power consumption (full load)- 19 W

-

-

-

... More
Heat dissipation (BTU- 64.8

-

-

-

... More
PoE power budget 115 W

-

-

-

... More
Switching capacity (aggregated-24 Gb/s

-

-

-

... More
Forwarding capacity-17.9 Mb/s

-

-

-

... More
Mac Address:16K or more VLAN: 4K or more System Policies: 1.5K or more Max Jumbo Frame: 9216 bytes Multicast Group: up to 1000

-

-

-

... More
Auto QoS for switch management traffic,Policy-based QoS, Traffic Prioritization, Priority Queues: Eight hardware-based queues per port, SPQ, WRR

-

-

-

... More
Static Routing, MSTP, RSTP, PVST+,IPv6 Tunneling, LACP, LAG, IGMPv3, DHCP, DHCP82,DHCP Relay for IPv4/IPv6,Multiple microcode image support with fallback recovery, ARP,SDN support through Restful API and openflow 1.3.1

-

-

-

... More
Loopback IP address support for management per service, Policy- and port-based mirroring, Remote port mirroring, sFlow v5 and Remote Monitoring (RMON), Unidirectional Link Detection (UDLD),Digital Diagnostic Monitoring (DDM), LLDP-MED, NTP,MVRP, SNMP, sflow or equivalent

-

-

-

... More
Dynamic change of authentication (CoA),MAC-based authentication for non-IEEE 802.1X hosts, MAC address lockdown, Prevention from ARP attacks, Web based Authentication, Autosensing IEEE 802.1X multi-client, multi-VLAN support,RFC 1321 MD5, RFC 2284 PPP EAP,RFC 1826/1827/4303/4305 Encapsulating Payload (ESP) and crypto algorithms, RFC 2104 HMAC Message Authentication, Built-in CPU protection against malicious attacks

-

-

-

... More
Unified management, control and virtual chassis technology, Virtual Chassis 1+N redundant supervisor manager, Virtual Chassis In-Service Software Upgrade (ISSU),Smart continuous switching technology, IEEE 802.3ad/802.1AX Link Aggregation Control Protocol (LACP) and static LAG groups across modules

-

-

-

... More
CE, EN 55032,24,35, RoHS, WEEE,REACH

-

-

-

... More
US UL 60950, CSA22.2

-

-

-

... More
EN 61000-3-2 & 3,EN 61000-3-2(all editions)

-

-

-

... More
EN 60825-1/2 Laser

-

-

-

... More
IEEE802.3: Hi-pot Test (2.25 KV DC on all Ethernet Ports)

-

-

-

... More
SFP should be of same make as switch.

-

-

-

... More
Vendor to be present in Gartner Magic Quadrant.

-

-

-

... More
The Switch shall work with on-premise and cloud based NMS without change in hardware/software/OS Image.

-

-

-

... More
Warranty-01 Years from OEM with Toll free number for support in India

-

-

-

... More
SITC of Network managent solution in virtual mode on industry standard Server with AI ops monitoring tool. ; Preferred Make- Allied Telesis/Alcatel -Lucent/Juniper/Cisco

1

-

-

... More
GENERAL

-

-

-

... More
A Solution that shall include a client/server Network Management System that is WEB 2.0 based, providing a WEB GUI for different types of PCs, tablets and smartphones.

-

-

-

... More
The NMS shall offer a single and consolidated interface for network deployment, troubleshooting, performance analysis and configuration operations.

-

-

-

... More
The NMS shall offer northbound interface RESTful APIs for application interoperability

-

-

-

... More
The NMS shall allow real-time monitoring and analysis of critical network performance indicators through visual and customizable widgets

-

-

-

... More
The proposed solution should be premise based and should support seamless migration to cloud without change in hardware/firmware of the switch. This should be based on standard server (Physical/Virtual)

-

-

-

... More
The centralized management function shall allow to display the physical topology of the network.

-

-

-

... More
The centralized management function shall be able to handle wired equipment (switches) and wireless (Acces Point) management for a “unified management” approach.

-

-

-

... More
The solution shall be able to automatically discover new Switch or APs added to the network.

-

-

-

... More
The solution shall be able to blacklist a client, either manually or automatically after a client attack has been detected.

-

-

-

... More
The centralized management function shall allow per equipment configuration and software backup and restore, and bulk backup and restore.

-

-

-

... More
TOPOLOGY

-

-

-

... More
The NMS shall build and present a visual topology for both logical and physical infrastructure with actual neighbor linkage info (IP subnet, layer 2, LLDP adjacency protocols) and live device status

-

-

-

... More
The NMS shall present logical maps based on user-defined filters (IP subnet, location…).

-

-

-

... More
NOTIFICATION MANAGER

-

-

-

... More
The NMS shall allow monitoring and analyzing alerts, notifications and network performance from network equipment from any vendor

-

-

-

... More
The NMS shall offer advanced alert capabilities through customizable filtering and sorting capabilities.

-

-

-

... More
The NMS shall allow remediation and notifications actions based on predefined conditions with a single click

-

-

-

... More
LOCATOR

-

-

-

... More
The NMS shall be able to locate devices in the network based on MAC address or IP Address, irrespective whether the device is located on a fixed or wireless network.

-

-

-

... More
RESSOURCE MANAGER

-

-

-

... More
The NMS shall allow mass programmable equipment configuration by the mean of scripts.

-

-

-

... More
The NMS shall allow infrastructure-wide software image update for baseline version management

-

-

-

... More
UNIFIED ACCESS

-

-

-

... More
The NMS shall offer a unified user interface for wired and wireless role profiles for user based access

-

-

-

... More
The NMS shall offer a wired and wireless cohesive authentication configuration and end-user profile definition for appropriate network access rights and dynamic policies

-

-

-

... More
ADDATIONAL FEATURES

-

-

-

... More
The centralized management function shall allow access to all wIPS/wIDS features.

-

-

-

... More
The centralized management function shall offer, on the basis of an application signature file, insight at application layer (e.g. facebook.com, youtube.com, salesforce.com…) even if the applications run on top of the HTTP or HTTPs protocols. It shall also allow control of those applications.

-

-

-

... More
The solution should allow the admin to easily provision, manage and maintain a network infrastructure with alarms, unified access security policies

-

-

-

... More
The solution should provide full visibility into wireless, devices and applications, as well as predictive analysis for forward planning

-

-

-

... More
The management solution should act as comprehensive tools for infrastructure configuration, monitoring, security, device configuration, alert management, to accelerate, downtime resolution, and overall management.

-

-

-

... More
It should be web based interface with customizable dash board

-

-

-

... More
Provide details about problematic devices including temperature, memory etc

-

-

-

... More
Monitor network bandwidth and end device traffic pattern

-

-

-

... More
Provide top applications/users usage analytics real time and historical

-

-

-

... More
Port utilisation details and threshhold limits

-

-

-

... More
Provides threat mitigation through a secure perimeter against intrusion and malware attacks

-

-

-

... More
Should support third party network devices for basic SNMP and report

-

-

-

... More
SITC 01 Gigabit optical transceiver SFP. Supports monomode fiber over 1310nm wavelength nominal) with an LC connector. Preferred Make- Allied Telesis/Alcatel -Lucent/Juniper/Cisco

30

-

-

... More
SITC of Video Management and enterprise server,Intel Xeon Silver 4410Y, 32 GB RAM, Redundant PSU, 2 NIC GIG, License for Microsoft Windows Server 2022 standard edi tion, 64 and Accesoories,Make Dell/HP/Lenevo, 3YR Pro Support Next Business Day Onsite, Preferred Make- DELL/HP/LENOVO

1

-

-

... More
SITC of Video Management Operator Client System i9-13900/32GB/512 SSD + 1TB SATA/Win 11 Pro/No Monitor/DVDRW/5 yrs NBD/1000W / NVIDIAGeForce RTX™ 3070, 8 GB GDDR6, 3 DP, HDMI; Preferred Make-Dell/HP/Lenevo

8

-

-

... More
Supply, Installation, Testing and Commissioning of 55" LED Display Panel, with 4K Resolution : 3840 x 2160, 500 nits (cd/m2) Brightness, contrast ratio : 4000:1, Viewing Angle : 178° h/v, response time : 8ms, Display Colors- 16.7 Mill; Built in Speaker-10W+10W ; Inputs : HDMI x 2, DVI‐D, DisplayPort, Audio, RS‐232 Control, 100‐240 VAC @ 50/60Hz Power Supply, 24x7 Operation.; Preferred Make-SONY/Samsung/LG

8

-

-

... More
All the Switches, NMS, SFP Modules must be from the One OEM. Core to Access connectivity should be on 10G.

-

-

-

... More
OEM Criteria for Passive Networking items.

-

-

-

... More
OEM must provide declaration on conformity of all the passive components to the following standards: a) TIA/EIA 568-2.D ; b) TIA/EIA 568-3.D ; c) ISO/IEC 11801

-

-

-

... More
OEM must be a member in the TIA and BICSI organization. OEM shall have RCDD certified manpower in India for design support and validation. Certificate is Mandatory

-

-

-

... More
OEM should have valid ISO 9001 and ISO 14001 certificate on Design, development and manufacture of SW and HW solutions for communication networks.

-

-

-

... More
All the products must have RoHS Compliance and from One OEM

-

-

-

... More
6 Port LIU Switch : SITC of 6 Port Loaded LIU with SC Unit for 6 SM fiber Single Mode fibres OS2 (1 Nos. of Loaded Duplex adapter with Adapter plate) along with 1 Pc of Splice Tray - 6 Fiber Capacity & 6 Nos. of SC Pigtail - Pigtail 1 Meter SM Os2 (Make:Legrand/Molex/RIT/Siemon)

7

-

-

... More
Detailed Specs for Fiber Optic LIU Rack Mount LIU (6 Ports)

-

-

-

... More
Fiber optic patch panel : Fiber optic patch panel FMS Termination Drawer should have sufficient slots to accommodate 3 of 12/16 Port LC Adaptor Plates.

-

-

-

... More
Should have Slide type drawer structure

-

-

-

... More
Height: 1 U, 1.75 inches (12 & 24 Ports)

-

-

-

... More
Material: Cold Rolled Steel in surface coated by electrostatic epoxy powder

-

-

-

... More
Slots: FMS should have sufficient slots to accommodate adaptor plates

-

-

-

... More
Empty Slots of FMS should be covered with blank plates.

-

-

-

... More
Splice Tray : Splice Tray of ABS, Comply with UL 94V2 material should be supplied with LIU.

-

-

-

... More
Detailed Specs for 6/12/16 Port LC/SC Type Adaptor Plates (SM OS2)

-

-

-

... More
The adaptor plate should be pre-loaded with LC/SC Type Single ModeDuplex Adaptors.

-

-

-

... More
Port Density :6/12/16 LC/SC Single mode Ports

-

-

-

... More
All LC adapters should be duplex type with shutter for protection. Adapters should be snap mount for easy insertion and removal.

-

-

-

... More
Insertion Loss: 0.2 to 0.1 dB

-

-

-

... More
Compliance :RoHS Compliant

-

-

-

... More
Detailed Specs for LC Type 9/125μm SM Fiber Optic Simplex Pigtail

-

-

-

... More
Type : 9/125 micron fibre performance

-

-

-

... More
Jacket Material : LSZH complying to IEC 61034-1 & 2,IEC-60332-1, IEC-60754-1 & 2

-

-

-

... More
Operating Temperature: -40°C to +75°C

-

-

-

... More
Connector Insertion Loss: 0.30dB(Max)

-

-

-

... More
Attenuation: 1310/1550 : 0.36/0.22 dB/KM

-

-

-

... More
SITC of 12 Port LIU Switch : SITC of 12 Port Loaded LIU with SC Unit for 12 SM fiber Single Mode fibres OS2 (1 Nos. of Loaded Duplex adapter with Adapter plate) along with 1 Pc of Splice Tray - 12Fiber Capacity & 12 Nos. of SC Pigtail - Pigtail 1 Meter SM Os2 (Make:Legrand/Molex/RIT/Siemon)

7

-

-

... More
Detailed Specs for Fiber Optic LIU Rack Mount LIU (6 Ports)

-

-

-

... More
Fiber optic patch panel : Fiber optic patch panel FMS Termination Drawer should have sufficient slots to accommodate 3 of 12/16 Port LC Adaptor Plates.

-

-

-

... More
Should have Slide type drawer structure

-

-

-

... More
Height: 1 U, 1.75 inches (12 & 24 Ports)

-

-

-

... More
Material: Cold Rolled Steel in surface coated by electrostatic epoxy powder

-

-

-

... More
Slots: FMS should have sufficient slots to accommodate adaptor plates

-

-

-

... More
Empty Slots of FMS should be covered with blank plates.

-

-

-

... More
Splice Tray : Splice Tray of ABS, Comply with UL 94V2 material should be supplied with LIU.

-

-

-

... More
Detailed Specs for 6/12/16 Port LC/SC Type Adaptor Plates (SM OS2)

-

-

-

... More
The adaptor plate should be pre-loaded with LC/SC Type Single ModeDuplex Adaptors.

-

-

-

... More
Port Density :6/12/16 LC/SC Single mode Ports

-

-

-

... More
All LC adapters should be duplex type with shutter for protection. Adapters should be snap mount for easy insertion and removal.

-

-

-

... More
Insertion Loss: 0.2 to 0.1 dB

-

-

-

... More
Compliance :RoHS Compliant

-

-

-

... More
Detailed Specs for LC Type 9/125μm SM Fiber Optic Simplex Pigtail

-

-

-

... More
Type : 9/125 micron fibre performance

-

-

-

... More
Jacket Material : LSZH complying to IEC 61034-1 & 2,IEC-60332-1, IEC-60754-1 & 2

-

-

-

... More
Operating Temperature: -40°C to +75°C

-

-

-

... More
Connector Insertion Loss: 0.30dB(Max)

-

-

-

... More
Attenuation: 1310/1550 : 0.36/0.22 dB/KM

-

-

-

... More
24 Port LIU Switch : SITC of 24 Port Loaded LIU with SC Unit for 24 SM fiber Single Mode fibres SM OS2 (12 Nos. of Loaded Duplex adapter with Adapter plate) along with 1 Pc of Splice Tray - 24 Fiber Capacity & 24 Nos. of SC Pigtail - Pigtail 1 Meter SM (Make:Legrand/Molex/RIT/Siemon)

3

-

-

... More
SITC of Fiber Duplex Patch Cords SC-LC/SC-SC SM Patch Cord 2 mtr. (Make:Legrand/Molex/RIT/Siemon)

40

-

-

... More
Detailed Specs for Patch Cord, LC SC, Duplex, SM, Bend Insensitive G651, PC, LSZH

-

-

-

... More
Cable : LC/SC-SC/LC 9/125μm or 1310 μm SM Duplex Patch Cord Length : 2mtrs (as per requirement)

-

-

-

... More
Connectors : The optical fiber patch leads shall comprise of Single Mode 9/125μm or 1310 μm fiber with 2XLC type fiber connectors terminated at one end of fiber patch cord and 2xSC type connector at other end of the fiber patch cord

-

-

-

... More
Insertion loss should be better than ≤ 0.30 dB

-

-

-

... More
Jacket Material : LSZH complying to IEC 61034-1 & 2,IEC-60332-1, IEC-60754-1 & 2

-

-

-

... More
Attenuation: 50/1300 : 3.0/1.0 dB/KM

-

-

-

... More
Connector Loss : 0.30dB(max)

-

-

-

... More
Operating Temperature : -40°C to +75°C

-

-

-

... More
Supply and laying of 6 core Single mode OS2 Loose tube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. (Make:Legrand/Molex/RIT/Siemon)

2500

-

-

... More
Detailed Specs for Outdoor F/O Cable, Loose Tube, SM – 1x6 Fibers, Central Steel rod with CST, PE

-

-

-

... More
The fiber should be optimized for operation at 1310 nm and at 1550 nm.

-

-

-

... More
Should fulfill the requirements of ISO.IEC 11801 - 2nd Edition, type OS2, ITU-T REC G 652D spec IEC 60794-1-2 F5

-

-

-

... More
Fibre Count : 6 /12

-

-

-

... More
Fiber count per tube :6 / 12

-

-

-

... More
Filler count :4

-

-

-

... More
Filler Material : PP

-

-

-

... More
Max. Attenuation: At 1310 nm = 0.36 dB/km, At 1550 nm =0.22 dB/km

-

-

-

... More
Fibre/Tube Identification : Multi Tube

-

-

-

... More
Fibre protection (Tubes) : Polybutylene Terephthalate (PBT)

-

-

-

... More
Armouring : CST

-

-

-

... More
Thickness : 1.6mm

-

-

-

... More
Outer Sheath :UV Stabilised Polyethylene (PE)

-

-

-

... More
Central Strength Member: Steel wire coated with PE

-

-

-

... More
Water Blocking : Thixotropic Gel (Tube);

-

-

-

... More
Petroleum Jelly (Interstices)

-

-

-

... More
Cable Diameter (D) : 9.0 ± 0.5 mm

-

-

-

... More
Mass (Nominal) : 91 kg/km

-

-

-

... More
Min. Bending Radius (during Installation) : 20 D;D-Outer Diameter

-

-

-

... More
Max. Tensile Strength-Short Term : 1500N

-

-

-

... More
Max. Crush Resistance-Short Term : 2200N/100 mm

-

-

-

... More
Operating Temperature range : -40°C to +70°C

-

-

-

... More
Approved Make : Molex / RIT / SIEMON

-

-

-

... More
All the cable and accessories are from the same OEM

-

-

-

... More
SITC of Fully Loaded 24 port STP jack panel (24 port RJ-45 Loaded CAT-6 UTP 19" rackmountable patch panel preferbaly with 6 blocks). (Make:Legrand/Molex/RIT/Siemon)

14

-

-

... More
Detailed Specs for 19" 1U 24 port Sheilded Patch Panel

-

-

-

... More
Patch panel should be modular design, populates up to 24 STP keystone-type jacks in 1U

-

-

-

... More
Patch panel should be Enhanced with cable strain relief with retention tray; It should be single metal both front panel and rear tray

-

-

-

... More
Material: sub-rack made of MS Steel with dimension 44.4 mm : 482.6 mm : 105 mm (h:w:d) tray

-

-

-

... More
Information Outlet or connectin module should comply with the specification mentioned above in 2

-

-

-

... More
Standard : Conforms to IEC-60603-7 (603-7) for keystone-type, snap-on apertures

-

-

-

... More
Should be RoHS complied

-

-

-

... More
SITC of Straight LAN Patch Chord-1 Mtr (Make:Legrand/Molex/RIT/Siemon)

200

-

-

... More
Detailed Specs for Patch Cord, U/UTP 4P, Cat.6, length  1/2 Metre

-

-

-

... More
Standardization: Compliant with Cat.6, Class E requirements: ISO/IEC 11801 2nd Edition Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5

-

-

-

... More
Cable shield:  U/UTP

-

-

-

... More
Number of conductors : 8

-

-

-

... More
Stranding: 7 x 0.20 mm (24 AWG)

-

-

-

... More
Cable jacket characteristics: cable, metal-free

-

-

-

... More
Cable overall diameter: 6.5±0.2 mm

-

-

-

... More
Tube / Wire type: stranded conductor

-

-

-

... More
Insulation: solid polyolefin, 0.97±0.02 mm diameter

-

-

-

... More
Plug: Feature cable retension, with enhanced pull strength.

-

-

-

... More
Cat 6 patch cord plug to have round cable holder and strain relief boot to avoid bending.

-

-

-

... More
Jacket: PVC with 8 different color options

-

-

-

... More
Plug should have high repeatability cross talk performance

-

-

-

... More
SITC of Cat6 Shielded Field Termination Plug with Following Specifications (Make:Legrand/Molex/RIT/Siemon)

200

-

-

... More
Standardization: Compliant with Cat.6, Class EA requirements: ISO/IEC 11801 2nd Edition backward Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5

-

-

-

... More
Cable:  UTP/STP

-

-

-

... More
Number of conductors : 8

-

-

-

... More
Termination: IDC type Tool less

-

-

-

... More
RJ45 Plug Metal covers: Zinc die-casting with nickel plated

-

-

-

... More
RJ45 Plug contacts: Phosphor bronze with nickel plated

-

-

-

... More
Plastic Wire Organizer: PC, Color: White, UL 94V-0

-

-

-

... More
IDC Durability: ≥20 Termination cycles

-

-

-

... More
RJ45 Jack Durability: ≥750 Plug-Jack mating cycles per IEC 60603-7-81

-

-

-

... More
Operating Temperature: -10 degree C to +60 degree C

-

-

-

... More
Patch Cord retention strength: 7.7 Kg Max. according to IEC 60603-7-5

-

-

-

... More
Rj45 Plug Insertion force: 3.1 Kg Max according to IEC 60603-7-81

-

-

-

... More
Splicing of Armoured SM/MM Fibre Optics Cable: Splicing, testing and commissioning of supplied, OFC cable of 6-Core Armoured Fibre Optics

198

-

-

... More
Providing, fixing, fitting, installation and testing of 42 U Network Rack as server cabinet 19" LCS2 along with all standard accessories, 800mm (W), 1000mm (D), CRCA 'D' grade 1.6mm thick sheet, pwoder coated for cabinet , 4mm Toughened Tinted Glass Door and along with following accessories:- 1. Cooling fan 220/230V AC, of 90 CFM-- 4 Nos. , 2. Cable manager Metal 4 Nos. 3. PDU- 230V /AC 1 No., 6. Mounting Hardware (20 Sets of M-6 screws, washers, cage, nuts (Nickle Coated)- 3 Nos. ,7. Earthing strips copper 150mm H 1 No. 8. Door Lock 1 No. ,9. Caster Wheels (with breake) 2 Nos. 10. Caster Wheels (without breake) 2 Nos. ,11. Front Metal Band 1 No. (Preferred Make-Valrack/President/Rittal/Netrack

1

-

-

... More
SITC of 6 U Pole Mounted Outdoor Rack:19” Wall mount 6U 600W/500D IP55 protection Cabinet CRCA sheet, Top cover with (2)fan and filter. bottom cover with gland for cable entry(1), rain canopy(1) Front metal doors equipped with hood & IP55 filter for IP55 compatible cabinets,19” uprights facilitate in mounting of the 19” equipment. The mounting distance is in accordance with the standard DIN 41494, STANDARDS IEC 60529 : 2013 (NF C 20-010) Degrees of protection provided by enclosures (IP code) Permissible load bearing capacity - Upto 70 Kg,Corrosion Resistance Salt spray test according to ISO 9227 (NSS test) and IEC EN 60068-2-11 (Ka test) for 168 hours: degree of Rusting Ri1 according to ISO 4628-3, propagation ≤1 mm according to ISO 4628-8.Pure polyester powder coating paint applied by electrostatic dusting. Enclosures comes in one color. All components- RAL 7035 Pastel structure color . The rack should contain the follwing- One Metal Cable Manager - 01U - Plastic Cable Loop's Mountable - Black Fine Tex,One Cantiliver Tray - 01U - 255D - Pastal Fine Tex.One Packet Mounting Hardware Packet { Containg 1 Nos Each Of 3 } - 20 Set ,Power Distribution Unit - 06/13 Amp Multi-Standard - 06 Socket - Single Pole / Screw Mountable / 06 Amp MCB / Alternating Current - 06 Amp 3 Pin Plug with Power Cable 0.75 sq.mm 3 meter Length - Black Fine Tex. - Assembly– 1 No.; Preffered Make-Legrand/APW/Valrack/President

14

-

-

... More
SITC of single Run Outdoor Cat 6 Cable(Category 6 4 Pair U/UTP cable. A HDPE compound insulates the cores with a IEC 60332-1 complied LS0Hn Category 6 compliant LS0H inner sheath and FR PVC outer UV resistantn Suitable for outdoor Installations n Compliant to TIA/EIA-568-C.2 Supports ultra hi-speed data net works such as Gigabit Ethernet (1000 Base-T and 1000 Base-TX) and beyondn Incorporates central spine maintaining pair separationduring installation to ensure installation); (Make:Legrand/Molex/RIT/Siemon)

10675

-

-

... More
SITC of 9 Mtr. MS Swaged Pole alongwith Mounting Arrangement with ISI Standard; Preffred Make- SK Poles/Bajaj/Standard

10

-

-

... More
SITC of 32 MM OD and 25 MM ID HDPE Pipe with ISI Mark; Prefered Make- Sree/Mahavir/Modi

1500

-

-

... More
SITC of 3 Core 2.5 sq.mm Armored Copper Power Cable; Prefered Make-Polycab/Finolex/Havells

800

-

-

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles with MCB DB complete withconnections, testing and commissioning etc. as required.Prefered Make-Legrand/ABB/L&T

14

-

-

... More
Schedule Rate

-

-

-

... More
100 mm X 100 mm X 60 mm deep

200

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessed conduit as required. Preferred Make- AKG/NORPACK/Polycab/Dauphin

-

-

-

3000

-

-

... More
Sub-Total-A( LAN Solutions)

-

-

-

... More
SITC of Single Phase Online 05 KVA UPS Preffered Make-Delta/EATON/Numeric/BPE

4

-

-

... More
SITC of Single Phase Online 02 KVA UPS Preffered Make-Delta/EATON/Numeric/BPE

4

-

-

... More
SITC of 42 AH SMF Battery, with 24 months replacement

64

-

-

... More
VRLA- AGM maintenance -free

-

-

-

... More
4032 VAH

-

-

-

... More
SITC of MS Battery Rack suitable for 15 to 20 UPS Battery installation

8

-

-

... More
Chemical Earthing

8

-

-

... More
Supply, errection, fitting, fixing, commissioning and testing along with earth cutting, digging, earth refilling for chemical earthing of the building except G.I. Strips (25mmX5mm) Each earth pit has to be tested with earth tester 1000 V/1000 Ohms & the test report has to be submitted by the contractor to the department after certification of the same by the consultant. The above chemical earthing includes the provision of masonary enclosure and HDPE Earth Pit Cover 300mm X 300 mm (Under-floor earth inspection pit) having locking arrangement as earth chamber.The above chemical earthing includes the following items (3 Mtr Earthing)

-

-

-

... More
Each chemical earthing shall have following details:-

-

-

-

... More
Supply of Pollution free Earthcon Compound 4 bags of 25 Kg each

-

-

-

... More
Supply of 17.2 mm dia, 250 micron,molecularly bounded copper coated 3 Mtr long electrode. Tested as per IEC 62561-2. Meets the requirement of IS 3043 & IEC 60364-5-54. Tested for short circuit withstanding capacity. High Tensile strength. (UL Listed).

-

-

-

... More
Supply of Stainless Steel "U" Bolt Clamp

-

-

-

... More
Supply of HDPE Earth Pit Cover for earth chamber (Capacity of 5 ton)

-

-

-

... More
Sub-total-B( UPS System & Accessories)

-

-

-

... More
SITC of 4MP Outdoor ANPR Bullet camera with 1/1.8 inch CMOS, Effective pixels  2688(H) x 1520(V), 60fps, Sensitivity – (Measured according to IEC 62676 Part 5 Color 0.078 lx Mono 0.0011lx With IR 0.0 lx, 141 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Vehicles Detection up to 64 at a time,10.5 mm – 45 mm ( + - 2 mm) Automatic Varifocal (PiRIS) lens,  MicroSD card slot for edge recording, Motion, tamper and audio detection, FTP, IR range upto 140mtrs, ONVIF Profile S ,G,T& M , PoE,  IP66,IP67,IP6K9K and NEMA 4X, IK10, CE, FCC , UL certified. SD card support up to 2TB. Built in TPM, RSA 4096 bit; AES/CBC 256 bit, TLS 1.3, UL Cap/FIPS 140, NDAA Compliant, BIS. Preffered Make- BOSCH

6

-

-

... More
SITC of 1080p HD PTZ Camera with 1/2.8" progressive scan CMOS,Effective pixels 1920 x 1080 (2 MP), 60 FPS,40x Optical Zoom (4.25 mm–170 mm)(F 1.6 – F 4.95),32X Digital zoom,Minimum Illumination- Color: 0067 Lux , B/W: 0.0010 lux,IR distance 300m; 120dB WDR, H.265, H.264, MJPEG streams, Intelligent Dynamic Noise Reduction, BLC, White Balance, Pan Range 360° continuous, Tilt Range 20° above horizon, Pan/Tilt Modes - Pan: 0.1°/s - 400°/s; Tilt: 0.1°/s - 300°/s,Presets 256, Tours, Audio- 1/1 Channel In/Out, Micro SD card support up to, 32 individually configurable privacy masks, Alarm inputs/outputs - 2/3,Dual Power options, Any object, Object in field, Crossing line, Entering field, Leaving field, Loitering, Following route, Idle object, Removed object, Counter, Occupancy, Crowd detection, Condition change, Similarity search, Tampering, Object filters based on Duration, Size, Aspect ratio v/h, Object classes (Upright persons, Vehicles),detect up to 64 objects simulataneously, Auto tracking, Camera trainer, IP66 and NEMA 4X, IK10, ONVIF Profiles S, G,M & T, FCC, CE, UL Certified, ULCAP Data security with TPM & PKI. SD card support up to 2TB. Built in TPM, RSA 4096 bit; AES/CBC 256 bit, TLS 1.3, UL Cap/FIPS 140, NDAA Compliant, BIS. Preffered Make- BOSCH

9

-

-

... More
SITC of AI-Neural Networks based 3D PeopleTracking Video Analytics Software for Vehicle monitoring and guidance. Can detect Vehicle Started moving and Stop. Classification of Car, Bus, Truck, Motorcycle, Bicycle and parking assistance. Software can intelligently adapt to challenging situations like lighting differences or environmental conditions, such as rain, snow, clouds, blowing leaves, and shaking cameras and automatically reduce false alarms that way. Preffered Make- BOSCH

6

-

-

... More
Supply, Installation, Testing and Commissioning of Video Managemet software with Seamless management of digital video, audio, and data across IP network. Support of central monitoring/control/playback of cameras from different locations. Alarm management, Users management, recording quality management, Schedule recording, Drag & drop ,Bookmarks,snapshot, Pop-up alarm, site maps support, virtual matrix functaionality, Live & playback video, export, logbook, sequencing, GPU Decoding, LDAP Support, Up to 4 monitors support on a single Workstation, Dual-authorization logon, Email or SMS notification on alarm, Support for 3rd party cameras via RTSP, HTTP, MJPEG, ONVIF Profile S or better. Live Map support for camera plotting, Object Tracking support on multiple camera over Live Map, Complete system with 500 Device Licese including mandatory native N:N Recording Failover support. VMS shall seemlessly incorporate existing VMS, STORAGE and Client System to built up Centralize operation. Comprehensive Software Maintenance ( Existing + New Requirement) for 3 Year. Preffered Make- BOSCH

1

-

-

... More
SITC of NAS/SAN with RAID5 & RAID 6 configurable Storage Appliance for 30 Days of Recording for Newly required Cameras video & Metadata. Intel® Core™ i7-12700E or higher including 25 MB Intel® Smart Cache and Installed memory of 16 GB DDR5-4800 1Rx16 ECC , UDIMM. DUAL Redundant Power Supply, Rack Mount 3 U. 288 TB Gross Storage Support. Minimum 16 Hard Disk Slots with support of 18 TB per Slot.The Hardware includes System drive 2x SATA3 2.5' 480 GB Enterprise SSD, RAID1 configuration . Onboard graphics Intel® UHD Graphics 770 , 12 Gb/s Sixteen-Port SAS RAID Card , Shall include Microsoft Windows Server IoT 2022 for Storage Standard. Certifications UL,CE,FCC,NDAA,BIS. FIPS 140. Discreet TPM 2.0 Preffered Make- BOSCH

2

-

-

... More
SITC of Enterprise Grade Hard Disk, SATA-III, 18 TB , 7200 RPM for 30 Days Back up; Make-Seagate/WD

40

-

-

... More
Supply, Installation, Testing and Commissioning of Keyboard and Joystick Controller, USB, Multi backlit Keyboard ; Preffered Make- BOSCH

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.