Building Construction Department Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Building Construction Department - BCD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date9 Oct 2024
Closing Date16 Oct 2024
Tender Amount₹ 60,08,062 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode measurement compacted Volume).

122.39

-

-

... More
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement compacted volume).

64.92

-

-

... More
Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.

68.76

-

-

... More
Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.

9.23

-

-

... More
Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.

41.15

-

-

... More
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.

12.3

-

-

... More
Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I.

17.35

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)

29.15

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement :2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

28.85

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40mm nominal size)

1.05

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)

12.83

-

-

... More
Making plith protection 50mm thick of cement concrete 1:3:6 (1 Cement : 3 coase sand ( zone-III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth

94.58

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to Plinth Level- 1:1.5:3 (1 cement ; 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size)

16.68

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string course, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reionforcement : (1:1.5:3 (1 cement : 1.5 : coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size)

1.98

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size).

14.44

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, fotting, bases of columns, etc. for mass concrete

34.02

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Suspended Floors, roofs, landings, balconies and access platform

73.25

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, Plinth beams, girders, bressumers and cantilevers

86.5

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Column, Pillars, Piers, Abutments, Posts and struts

60.38

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges

29.21

-

-

... More
Providing Toe steel reinforcement of 8mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel) 8mm

1.49

-

-

... More
Providing Toe steel reinforcement of 10mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel) 10mm

0.83

-

-

... More
Providing Toe steel reinforcement of 12mm to 25mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel) 12mm to 25mm

1.01

-

-

... More
S/F M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction ofE/I. (Where materials is not supplied by the deptt.)

388.1

-

-

... More
Supplying, fitting and fixing 20mm dia M.S. Bar 1 meter long holding down bolt with nuts washers 100 X100 X6mm plate fitted and fixed with cement concrete (1:24) as per approved design all complete as per building specification and direction of E/I.

32

-

-

... More
Drilling 6mm dia hole M.S. angle iron for fixing of staples etc. as per building specification and direction of E/I.

504.9

-

-

... More
Labour for fabricating, erecting, hoistion and fixing in position structrral steel work in R.S. Joist, channel, Angle, Tee, flat, plate, latice member, built up compound section in column, girder, stair case, or truss including cost of gusset plates, holding down bolts, anchor plates at all heights and depths, bolting, welding ( machining wherever necessary) with applying a priming coat of red lead paint all complete as per approved drawing, building specification and direction of E/I.

0.45

-

-

... More
Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and direction of E/I.

314.74

-

-

... More
Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.

237.43

-

-

... More
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I.

53.72

-

-

... More
Extra for providing and fixing 30X4mm glass strips in joints of flooring , complete job as per specification and direction of E/I.

237.43

-

-

... More
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.

31.68

-

-

... More
Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.

251.41

-

-

... More
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.

298.59

-

-

... More
Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.

101.71

-

-

... More
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.

31.68

-

-

... More
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l.

1579.17

-

-

... More
Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding , curing and taxes all complete as per building specification and direction of E/I.

740.26

-

-

... More
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specificatio).

41.76

-

-

... More
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.

313.89

-

-

... More
Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.

1.05

-

-

... More
Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.

140.47

-

-

... More
Dsimantling old plaster and pointing in cement or lime and raking out joints to 15mm depth watering and disposal of unserviceable materials with all leads all complete as per direction of E/I.

422.63

-

-

... More
Taking down old door and window shutters including stacking serviceable materials with all leads all complete as per direction of E/I.

13

-

-

... More
Taking down chaukhats in doors including stacking serviceable materials with all leads all complete as per direction of E/I.

6

-

-

... More
Taking down chaukhats in windows including stacking serviceable materials with all leads all complete as per direction of E/I.

7

-

-

... More
Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.

78.1

-

-

... More
Providing 19mm thick water proof cement plaster (1:3) with clean coasre sand of F.M. 1.5 with integral water proofing compound Liquid @ 125ml per bag cement including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. Brand-Sika-Plastocrate plus, MYK proof WP 10, Fosroc-Conplast X4211C, Dr. Fixit Pidiproof LW+ or Equivalent

96.39

-

-

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 mabove ground level and removal of rubbish up to a distance of 50 moutside the periphery of the area cleared.

1380.11

-

-

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete.

69.7

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot Finished Welded Type Tubes

1932.16

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gatesand similar works

458.85

-

-

... More
Providing and fixing angle iron frames for doors, windows and ventilatorsof mild steel Angle sections of size 35x35x5 mm, joints mitred andwelded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existingT-iron frame or to the wall with dash fastener, including fixing of necessarybutt hinges and screws and applying a priming coat of approved steelprimer, all complete as per the direction of Engineer-In-charge.

1197

-

-

... More
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matchingpigments etc., complete.

23.79

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

60.73

-

-

... More
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges Plain (500-600mm)

10.06

-

-

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm)

887.57

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

2466.75

-

-

... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratchesetc. complete

2601.18

-

-

... More
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick

461.59

-

-

... More
Extra for covering top of membrane with Geotextile, 120 gsm nonwoven, 100% polyester of thickness 1 to 1.25 mm bonded to themembrane with intermittent touch by heating the membrane by ButaneTorch as per manufactures recommendation.

461.59

-

-

... More
Providing and fixing concertina coil fencing with punched tapeconcertina coil 600 mm dia 10 metre openable length ( total length90 m), having 50 nos rounds per 6 metre length, upto 3 m height ofwall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apartand with 9 horizontal R.B.T. reinforced barbed wire, stud tied withG.I. staples and G.I. clips to retain horizontal, including necessarybolts or G.I. barbed wire tied to angle iron, all complete as per directionof Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Springcore (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mmwith tape (0.52 mm thick) and weight 43.478 gm/ metre (cost ofM.S. angle, C.C. blocks shall be paid separately)

153

-

-

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 gradewith approved colour, design & pattern.

336.17

-

-

... More
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge

-

-

-

... More
50 mm Avrage Thickness

7.77

-

-

... More
25 mm Avrage Thickness

34.9

-

-

... More
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.

-

-

-

... More
Bars upto 12 mm diameter

335

-

-

... More
Bars above 12 mm diameter

55

-

-

... More
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. 25 mm average thickness in 2 layers.

34.9

-

-

... More
Providing, mixing and applying SBR polymer (of approved make @ minimum 2% by wt. of cement used) modified plain/reinforced cement concrete for structural members having minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness.

-

-

-

... More
Note: Rates shall be for finished surface area of concrete and shall include the cost of labour, concrete and appropriate approved Super- Plasticiser for rendering concrete as flowable and SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument)

-

-

-

... More
50mm thick in Grade M 25 with cement content not lessthan 330 kg per cum

7.77

-

-

... More
Supplying fitting & fixing Angle iron post (b) Angles size in mm as per I.S. 226 (ii) 50 x50 x 6/8/10 (Gr. A)

0.45

-

-

... More
Caraige of materials

-

-

-

... More
Bricks Lead = 8km (7p+1k)

46081

-

-

... More
Sand lead = 10 km

182.99

-

-

... More
Stone chips lead = 22 km

88.71

-

-

... More
Stone metal lead = 22 km

16.02

-

-

... More
Cement - Lead 10km

52.28

-

-

... More
Steel - Lead 10km

6.09

-

-

... More
Fly Ash Lead - 15km

6171

-

-

... More
Paver Block - 15km

9517

-

-

... More
Earth-3 km

111.51

-

-

... More
Disposal of Earth-5 km

41.63

-

-

... More
DT : Basic rates for 125/115mm dia drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of E/I.. (Basic Rates) Drilling upto 30 mtr. Depth below G.L. in Rural Area

30

-

-

... More
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressure and equipmentsas well as fule, lubricants and cost of transportation of rig machine and other vehical up to Site.

-

-

-

... More
(a) From 0.00 M to 50.00 M below G.L.

50

-

-

... More
(b) From 51.0 M to125.00 M

75

-

-

... More
(c) From126.0 M to150.00 M

25

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia

25

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 100 mm nominal size dia

30

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for allleads & lifts, all complete as per direction of Engineer-in-charge

3.34

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge

3.34

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge

3.34

-

-

... More
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge

2

-

-

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia

2

-

-

... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp

2

-

-

... More
Supplying Submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. the pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible Pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages - 2 HP

1

-

-

... More
Supplying Fully automatic star delta starter to operate induction motor working on 415V, 3 phase, 50 hz with no volt coil, Over load element, ON-OFF push buttons, with necessary materials and connected to supply, etc. complete starter with original sheet steel encloser as per IS : 3914

1

-

-

... More
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.

130

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 50 mm nominal dia Pipes

115

-

-

... More
Point wiring in PVC consuit, with piano type switch - Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as required

-

-

-

... More
Group A

12

-

-

... More
Group C

8

-

-

... More
Power plug wiring in PVC conduit (2 x 4 sq. mm) :- Wiring for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc as required.

35

-

-

... More
Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.

-

-

-

... More
2x1.5 Sqmm + 1x1.5 sqmm earth wire (For 5/6A Plug Points)

37

-

-

... More
2x2.5 Sqmm + 1x2.5 sq mm earth wire

73

-

-

... More
2 x 6.0 sq.mm + 1 x 6.0 sq.mm earth wire

20

-

-

... More
Wiring in existing conduit - Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required.

-

-

-

... More
3x1.5 sq mm

95

-

-

... More
3x2.5 sq mm

65

-

-

... More
S/F PVC /G.I. boxes - Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required.

-

-

-

... More
72mm x 146mm x 48mm deep/(4" x 7")

2

-

-

... More
147mm x 93mm x 47mm deep/(5" x 7")

3

-

-

... More
72mm x 226mm x 48mm deep/(4" x 10")

2

-

-

... More
S/F piano type switch/socket - Supplying and fixing following piano tyep switch/socket on the existing switch box/cover including connections etc. as required.

-

-

-

... More
5/6 amps, one way switch

15

-

-

... More
15/16 amps, one way switch

2

-

-

... More
3 pin 5/6 amps, socket outlet

3

-

-

... More
6 pin15/16 amps, socket outlet

2

-

-

... More
Electronic step fan regulator, mini

8

-

-

... More
S/F ceiling rose - Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required.

15

-

-

... More
S/F Batten holder - Supplying and fixing batten/angle holder including connection etc. as required.

15

-

-

... More
ITC fluorescent fitting directly on surface - Installtion, testing and commissioning of Pre-wired, fluorescent fitting/compact fluorescent fitting of all type, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq.mm. FR PVC insulated, copper conduit.

8

-

-

... More
ITC exhaust fan upto 450mm sweeo - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing commissioning etc. as required.

3

-

-

... More
S/F rewireable double pole/ TP&N switch disconnector :- Providing and fixing following DP/TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewireable type fuses, including drilling holes in metal board . making connections. etc. as required. 32 amps, double pole

1

-

-

... More
S/F S.P. MCB DB - Supplying and fixing following way single pole netural, sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator)

-

-

-

... More
2way, Single door

1

-

-

... More
8 way, Single door

1

-

-

... More
S/F 'B' series, S.P. MCB - Supplying and fixing 6 amps to rating, 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required 6/32 amps, single pole "B" series

10

-

-

... More
S/F DP MCB Isolator - Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps

1

-

-

... More
Earthing with G.I. earth pipe 4.5 mtr. Long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required

1

-

-

... More
Supply, Installation, testing and commissioning of following, size ceiling fan 3 Blades confirming to IS : 374 : 2019 including wiring the down rods of standard length (up to 30cm) with 1.5 sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required. 1200mm (48") ceiling Fan

8

-

-

... More
S.I.T.C. of following rating, surface mounted LED light fitting, suitable for 230V 50Hz, single phase supply etc. complete as required. 20/22W LED Tube Light

10

-

-

... More
9/10Watt LED Bulb

23

-

-

... More
12" (300mm) metal exhaust fan

3

-

-

... More
48" ceiling fan rewinding with ball bearing

10

-

-

... More
48' Celing fan blade ( for 20 no ceiling fan)

10

-

-

... More
Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350 gms.) with extra socket all complere as per specification and direction of E/I.

4

-

-

... More
Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I. Brass Stop Cock - 15mm dia

2

-

-

... More
Providing and fixing Gun metal full way valve of approved quality all complete as per specification and direction of E/I.

-

-

-

... More
25mm dia and weight not less than 500 gms

8

-

-

... More
32mm dia and weight not less than 500 gms

4

-

-

... More
Cutting chajja or cornice for laying G.I. pipe and restoring the same with R.C.C. (1:2:4) brick work in cement mortar (1:4) and cement plaster (1:4) as per specification and direction of Engineer-in-charge.

2

-

-

... More
Making holes in walls for laying G.I. pipes and restoring the same after pipe laying as per specification and direction of E/I.

-

-

-

... More
125mm thick wall

4

-

-

... More
250mm thick wall

4

-

-

... More
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. C.P. brass soap dish container medium quality with screw and hinges etc.

4

-

-

... More
Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. 580mm long - With 10 liter low level PVC cistern

4

-

-

... More
Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of Hindustan 'Parry' or any other approved I.S.S. make with 5 litres capacity C.i. automatic flusing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm PVC/Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including priming coat of red oxide, cutting wall and floor making good the same etc. all complete as per specification and direction of E/I. Flat back or standard corner (600mm x 350mm)

2

-

-

... More
Supplying fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body brass spindl stop cock approved quality of weight not less than 30 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.

4

-

-

... More
Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of exacavted earth within initial lead and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. For classification of soil item - A

5.4

-

-

... More
Lbour for alying, fitting and fixing NP2 R.C.C. spun pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leakproof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complet as per specification and direction of E/I. 150mm dia RCC spun pipe - Upto 3.0 metre depth of invert below G.L.

80

-

-

... More
Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.

6

-

-

... More
Supplying and fixing NP2 Hume pipe etc. (150mm dia)

80

-

-

... More
Providing and fixing on wall face unplasticied Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion (i) Single socketed pipes.

-

-

-

15

-

-

... More
110 mm

10

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Single tee with door - 75x75x75 mm

4

-

-

... More
Single tee with door - 110x110x110 mm

3

-

-

... More
Single tee without door - 75x75x75 mm

4

-

-

... More
Single tee without door - 110x110x110 mm

3

-

-

... More
Bend 87.5° - 75mm

4

-

-

... More
Bend 87.5° - 110mm

3

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes

50

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.

-

-

-

... More
15 mm nominal outer dia Pipes

20

-

-

... More
20 mm nominal outer dia Pipes

20

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.

2000

-

-

... More
Providing and fixing PTMT, push cock of approved quality and colour. 15 mm nominal bore, 98 mm long, weighing not lessthan 75 gms

6

-

-

... More
Providing and fixing PTMT grating of approved quality and colour. C.P. Gratings

-

-

-

... More
Circular type - 100mm dia

2

-

-

... More
Circular type - 125 mm dia

2

-

-

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5

1

-

-

... More
Bala Painting in Wall (L.S)

45

-

-

... More
Add 18 % GST (in Basic Rate must fill 12)

18

-

-

... More
Add 1% Labour Cess (in Basic Rate must fill 1)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.