Bharat Coking Coal Limited Tender

Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Bharat Coking Coal Limited - BCCL Tender

Civil And Construction
Electrical and Electronics
Pipe Line Project
Electrical Works
Eprocure
Opening Date26 Nov 2022
Closing Date4 Dec 2022
Tender Amount₹ 1,60,065 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down of one no. PVC insulated power cable of 185 sq mm for making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)

30

-

44

... More
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 185/240 sq mm size of 3 core, XLPE Aluminium conductor cable of 11 KV grade (CPWD SOR' 2012, P-34, 10.2.3)

1

-

8029

... More
Laying/Hanging of one no. PVC insulated power cable of 185 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)

30

-

44

... More
Making new jumper with O/H line

9

-

240

... More
Opening & re-connection cable lead from breaker

6

-

240

... More
B) for 3 No. O/H line maintenance - Erection of Dog Conductor 336 meters of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22) @ 0.394 Kg/Mtr

132.38

-

85.5

... More
Damage & weak jumper repairing with binding wire etc.

3

-

240

... More
Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (Dog Conductor 328 Meters) (CPWD SOR' 2012, P-40, 12.40) @ 0.394 Kg/Mtr

129.23

-

27.5

... More
Tree & branches cutting below O/H line (Semi Skilled)

2

-

593

... More
C) for 6 No. 6.6 KV feeder O/H line maintenance - Damage & weak jumper repairing with binding wire etc.

12

-

240

... More
Opening jumper for searching faults & after megguring re-jumpering

42

-

240

... More
Opening cable jumper from O/H line

12

-

240

... More
Taking down of Two nos PVC insulated power cable of 185/240 sq mm for making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)

40

-

44

... More
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 185/240 sq mm size of 3 core, XLPE Aluminium conductor cable of 11 KV grade (CPWD SOR' 2012, P-34, 10.2.3)

2

-

8029

... More
Laying/Hanging of Two nos PVC insulated power cable of 185/240 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)

40

-

44

... More
Making new cable jumper with O/H line

15

-

240

... More
Dismantle of disc/pin insulator for 11 KV over head lines as required. (CPWD SOR' 2012, P-42, 13.12)

6

-

53

... More
Dismantle of bracket & clamps

69.97

-

19

... More
Transportation of pole at site

4

-

593

... More
Erection of metallic pole of 10 - 12 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (CPWD SOR' 2012, P-36, 11.3.4)

1

-

3482

... More
Fabrication & erection of bracket & clamps

69.97

-

38

... More
Erection of disc/pin insulator for 11 KV over head lines as required. (CPWD SOR' 2012, P-42, 13.12)

10

-

53

... More
Erection of stay wire with boi

2

-

2000

... More
Erection of Wolf Conductor 410 meters of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22) @ 0.726 Kg/Mtr

297.66

-

85.5

... More
Erection of Lightening Arrestor

6

-

800

... More
Dismantle of jumper for changing of faulty disc

2

-

240

... More
Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (ACSR wolf conductor 110 Meters) (CPWD SOR' 2012, P-40, 12.40) @ 0.726 Kg/Mtr

79.86

-

27.5

... More
Supply & erection of 11 KV Disc insulator for O/H line with galvanised insulator fittings, bolts, nuts, washers etc. as required (CPWD SOR' 2012, P-42, 13.11)

2

-

1171

... More
Supply & erection of 11 KV Pin insulator complete with large steel head G.I pin, nuts, washers etc. as required (CPWD SOR' 2012, P - 42, 13.10)

2

-

369

... More
Jumpering after changing of new Disc insulator

2

-

240

... More
D) for Motor Connection O/H line maint - Laying/Hanging of one no. PVC insulated power cable of 1.1 KV grade of 70 sq mm after making fresh lead (CPWD SOR' 2012, P-27, 7.5.2)

30

-

18.5

... More
Mechanical joint in switch with HT tape & others materials

1

-

2398

... More
Making new jumper with O/H line

3

-

240

... More
E) for 2 No. LT O/H line maintenance - Erection of Dog Conductor 504 metres of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22) @ 0.394 Kg/Mtr

198.58

-

85.5

... More
Laying/Hanging of one no. PVC insulated power cable of 11 KV grade of 185 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)

30

-

44

... More
Laying/Hanging of one no. PVC insulated power cable of 1.1 KV grade of 70 sq mm after making fresh lead (CPWD SOR' 2012, P-27, 7.5.2)

30

-

18.5

... More
Jumpering above cables with O/H line

4

-

240

... More
F) for 13 No. Colony LT O/H line maintenance - Laying/Hanging of one no. PVC insulated power cable of 1.1 KV grade of 70 sq mm after making fresh lead (CPWD SOR' 2012, P-27, 7.5.2)

30

-

18.5

... More
Mechanical joint in Motor with HT tape & others materials

1

-

2398

... More
Making new jumper with O/H line

3

-

240

... More
Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (Dog Conductor 150 Meters) (CPWD SOR' 2012, P-40, 12.40) @ 0.394 Kg/Mtr

59.1

-

27.5

... More
Tree & branches cutting below O/H line (Semi Skilled)

6

-

593

... More
Total impact of GST for the purpose of CTC

1

-

28811.6



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.