Bharat Coking Coal Limited Tender
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 10,657Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BCCL_311842_1Bid Award Id
ViewTender No
BCCL/KB/EandM/PS/OTE/24-25/14 Dt.-03/07/2024Tender Authority
Bharat Coking Coal Limited ViewPurchaser Address
-Website
http://http://www.bcclweb.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Group B
Calculation: Qty. for 01 Qtr. = 30 Points
Qty. for 04 Qtrs. = 4 x 30 = 120 Points
120
54787
456.56
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
-
-
-
5/6 amps switch
Calculation: Qty. for 01 Qtr. = 24 Nos.
Qty. for 04 Qtrs. = 4 x 24 = 96 Nos.
96
2591
26.99
3 pin 5/6 amp socket outlet
Calculation: Qty. for 01 Qtr. = 24 Nos.
Qty. for 04 Qtrs. = 4 x 24 = 96 Nos.
96
3118
32.48
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Calculation: Qty. for 01 Qtr. = 13 Nos.
Qty. for 04 Qtrs. = 4 x 13 = 52 Nos.
52
10704
205.86
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Calculation: Qty. for 01 Qtr. = 135 Mtrs.
Qty. for 04 Qtrs. = 4 x 135 = 540 Mtrs.
540
52866
97.9
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Calculation: Qty. for 01 Qtr. = 160 Mtrs.
Qty. for 04 Qtrs. = 4 x 160 = 640 Mtrs.
640
76704
119.85
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Calculation: Qty. for 01 Qtr. = 270 Mtrs.
Qty. for 04 Qtrs. = 4 x 270 = 540 Mtrs.
1080
160077
148.22
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Calculation: Qty. for 01 Qtr. = 52 Mtrs.
Qty. for 04 Qtrs. = 4 x 52 = 208Mtrs.
208
39203
188.48
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution boards, 240 Volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB / Isolator)
-
-
-
2 + 8 way, Single door
Calculation: Qty. for 01 Qtr. = 4 Nos.
Qty. for 04 Qtrs. = 4 x 4 = 16 Nos.
16
8095
505.97
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole
Calculation: Qty. for 01 Qtr. = 23 Nos.
Qty. for 04 Qtrs. = 4 x 23 = 92 Nos.
92
11868
129
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
63 amps
Calculation: Qty. for 01 Qtr. = 3 Nos.
Qty. for 04 Qtrs. = 4 x 3 = 12 Nos.
12
3326
277.23
Supplying and fixing of domestic fan regulator Calculation: Qty. for 01 Qtr. = 6 Nos.
Qty. for 04 Qtrs. = 4 x 6 = 24 Nos.
24
3638
151.62
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Calculation: Qty. for 01 Qtr. = 24 Nos.
Qty. for 04 Qtrs. = 4 x 24 = 96 Nos.
96
5533
57.64
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Calculation: Qty. for 01 Qtr. = 25 Nos.
Qty. for 04 Qtrs. = 4 x 25 = 100 Nos.
100
3111
31.11
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
Calculation: Qty. for 01 Qtr. = 6 Nos.
Qty. for 04 Qtrs. = 4 x 6 = 24 Nos.
24
1614
67.25
Call Bell 230 volt
Calculation: Qty. for 01 Qtr. = 1 Nos.
Qty. for 04 Qtrs. = 4 x 1 = 4 Nos.
4
442
110.58
100 Amps 3 phase copper busher, Size: 1' x 1'
Calculation: Qty. for 01 Qtr. = 1 Nos.
Qty. for 04 Qtrs. = 4 x 1 = 4 Nos.
4
10091
2522.97
Supply and laying of 1.1KV grade 4 core, 50sq.mm PVC armoured aluminium cable.
Calculation: Qty. for 01 Qtr. = 50 Mtrs.
Qty. for 04 Qtrs. = 4 x 50 = 200 Mtrs.
200
74566
372.83
Labour Charges for dismantling of old existing wiring, etc.
-
-
-
Un-skilled
Calculation: Qty. for 01 Qtr. = 02 Heads
Qty. for 04 Qtrs. = 4 x 2 = 8 Heads
8
5024
628
Skilled
Calculation: Qty. for 01 Qtr. = 02 Heads
Qty. for 04 Qtrs. = 4 x 2 = 8 Heads
8
6656
832
Complete electrical wiring of 02 Nos. of C-type quarters (C-91 & C-II/38 of Sec.-VII) at Koyla Nagar.
-
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
-
-
-
Group A
Calculation: Qty. for 01 Qtr. = 14 Points
Qty. for 02 Qtrs. = 14 x 2 = 28 Points
28
10657
380.62
Group B
Calculation: Qty. for 01 Qtr. = 11 Points
Qty. for 02 Qtrs. = 2 x 11 = 22 Points
22
10044
456.56
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
-
-
-
5/6 amps switch
Calculation: Qty. for 01 Qtr. = 14 Nos.
Qty. for 02 Qtrs. = 2 x 14 = 28Nos.
28
755
26.99
3 pin 5/6 amp socket outlet
Calculation: Qty. for 01 Qtr. = 14 Nos.
Qty. for 02 Qtrs. = 2 x 14 = 28 Nos.
28
909
32.48
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Calculation: Qty. for 01 Qtr. = 7 Nos.
Qty. for 02 Qtrs. = 2 x 7 = 14 Nos.
14
2882
205.86
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Calculation: Qty. for 01 Qtr. = 80 Mtrs.
Qty. for 02 Qtrs. = 2 x 80 = 160 Mtrs.
160
19176
119.85
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Calculation: Qty. for 01 Qtr. = 130 Mtrs.
Qty. for 02 Qtrs. = 2 x 260 = 260 Mtrs.
260
38537
148.22
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Calculation: Qty. for 01 Qtr. = 35 Mtrs.
Qty. for 02 Qtrs. = 2 x 35 = 70 Mtrs.
70
13193
188.48
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution boards, 240 Volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB / Isolator)
-
-
-
2 + 8 way, Single door
Calculation: Qty. for 01 Qtr. = 2 Nos.
Qty. for 02 Qtrs. = 2 x 2 = 4 Nos.
4
2023
505.97
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole
Calculation: Qty. for 01 Qtr. = 14 Nos.
Qty. for 02 Qtrs. = 2 x 14 = 28 Nos.
28
3612
129
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
63 amps
Calculation: Qty. for 01 Qtr. = 2 Nos.
Qty. for 02 Qtrs. = 2 x 2 = 4 Nos.
4
1108
277.23
Supplying and fixing of domestic fan regulator Calculation: Qty. for 01 Qtr. = 4 Nos.
Qty. for 02 Qtrs. = 2 x 4 = 8 Nos.
8
1212
151.62
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Calculation: Qty. for 01 Qtr. = 12 Nos.
Qty. for 02 Qtrs. = 2 x 12 = 24 Nos.
24
1383
57.64
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Calculation: Qty. for 01 Qtr. = 13 Nos.
Qty. for 02 Qtrs. = 2 x 13 = 26 Nos.
26
808
31.11
Call Bell 230 volt
Calculation: Qty. for 01 Qtr. = 1 Nos.
Qty. for 02 Qtrs. = 2 x 1 = 2 Nos.
2
221
110.58
Labour Charges for dismantling of old existing wiring, etc.
-
-
-
Un-skilled
Calculation: Qty. for 01 Qtr. = 02 Heads
Qty. for 02 Qtrs. = 2 x 2 = 4 Heads
4
2512
628
Skilled
Calculation: Qty. for 01 Qtr. = 02 Heads
Qty. for 02 Qtrs. = 2 x 2 = 4 Heads
4
3328
832
Total impact of GST for the purpose of CTC
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements