Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.

Bharat Coking Coal Limited - BCCL Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date16 Mar 2024
Closing Date21 Mar 2024
Tender Amount₹ 2,54,762 
Notes
Download

Costs

Summary

Transformer Repairing,500kva/1000kva

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cork sheet for primary and secondary bushing

7

5600

800

... More
Oil seal for primary and secondary stud

7

3500

500

... More
Cork sheet for top cover cooling Buchholz relay and conservator

2

3200

1600

... More
Copper stud secondary side with complete set with insulator including nut lock washer check nut

3

10500

3500

... More
Transformer oil filtration

300

2100

7

... More
Labour charge for cork sheet changing of top cover cooling Buchholz relay and conservator

1

7000

7000

... More
B) Cork sheet changing, oil filtration and overhauling of transformer (a) 100kVA, 6.6kV/3.3kV and (b) 300kVA, 11kV/550V of 07/08 substation and CAP-02 substation respectively TMC Colliery

-

-

-

... More
B) a)100 kVA Transformer 6.6kV/3.3kV S.No. 8450, Make Synergy Pvt Equipment pvt ltd S.No. 8450 at 7/8 Electrical substation of Tetulmari Colliery

-

-

-

... More
Transformer oil draining and refilling

600

2400

4

... More
Top cover opening and fitting the same after cleaning

2

6000

3000

... More
Internal and external cable connection opening and refitting the same after propoer insulation both side

7

11200

1600

... More
Cork sheet for primary and secondary bushing

7

5600

800

... More
Oil seal for primary and secondary bushing

7

3500

500

... More
Cork sheet for top cover cooling Buchholz relay and conservator

2

3200

1600

... More
Copper stud secondary side 15" X 02" with complete set nut lock washer check nut.

2

17000

8500

... More
Copper stud primary side 15" X3/4" with complete set nut lock washer check nut.

1

3500

3500

... More
oil filtration

1250

25000

20

... More
oil filtration M/C Up and down transporting

2

2000

1000

... More
B) b) 300kVA transformer 11kV/550V, S.No. 13003, make Crompton Parkinson at CAP-02, Electrical Substation of Tetulmari Colliery

-

-

-

... More
Transformer oil draining and refilling

400

1600

4

... More
Top cover opening and fitting the same after cleaning

2

6000

3000

... More
Internal and external cable connection opening and refitting the same after propoer insulation both side

7

11200

1600

... More
Cork sheet for primary and secondary bushing

7

5600

800

... More
Oil seal for primary and secondary bushing

7

3500

500

... More
Copper stud secondary side 12" X 02" with complete set nut lock washer check nut.

3

25500

8500

... More
Copper stud primary side 12" X3/4" with complete set nut lock washer check nut.

3

10500

3500

... More
Energy charges for heating and baking of core and coil

1

2500

2500

... More
Copper patti 2"

12

13200

1100

... More
Oil Filtration

600

12000

20

... More
oil filtration M/C Up and down transporting

2

2000

1000

... More
pre-commissioning test of transformer

1

5500

5500

... More
Total impact of GST for the purpose of CTC

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.