Airports Authority Of India Tender
... More
Search from across the categories, cities, and authorities to find the latest Jharkhand tenders. Every Jharkhand tender is curated from credible sources of government websites (eProcurement Jharkhand portal) and newspapers, thus ensuring the credibility of the information presented to you. For more information on Jharkhand tender bidder registration, the login process and more read the FAQs section on this page.
Costs
EMD
₹ 5,71,246Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_AAI_153007_1Bid Award Id
ViewTender No
AAI/RNC/ARMO-NITB/2023Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://https://www.aai.aero/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
ARMO of EandM Installations at BM Airport Ranchi. SH Providing Maintenance Services for EandM Installations of NITB, Sub-station, AAI Residential Colony, Old TB, CISF barrack, MT pool and cargo division for the year 2023-25.
ARMO of EandM Installations at BM Airport Ranchi. SH Providing Maintenance Services for EandM Installations of NITB, Sub-station, AAI Residential Colony, Old TB, CISF barrack, MT pool and cargo division for the year 2023-25.
BOQ Items
... More
Sub Head - I : Operation and Maintenance
Coordination for renewal of CEA Licence at New terminal Building and runway power house by providing assistance in submission of drawings, reports, documents etc. including getting site inspection by CEA authorities to obtain approval of licence and submission to AAI. Statutory govt. fees shall be paid by AAI derectly to CEA. Any associated works if necessary as per CEA observation during inspection shall be carried out by AAI through the AMC as required.
1
-
-
... More
Sub Head - II : Repair and Painting Works
Transportation of diesel from AAI authorised petrol pump to power house( to and fro 08 KM) in 200 Ltr. barrels/ drums including loading/ unloading (for 600- 800 Ltr.) per trip as and when required.
200
-
-
... More
Sub Head - II : Repair and Painting Works
Annual maintenance contract of Rockwell automation make (model : Allen Bradley) Micrologix 1400 PLC for automatic operation of 5 nos. of D.G. sets (AMF panel with synchronization).including control circuit from DG Sets to AMF panels, AMF panels, and other LT panels in Sub-Station.
-
-
-
... More
I st year
1
-
-
... More
II nd year
1
-
-
... More
Sub Head - II : Repair and Painting Works AMC of hydraulic crash rated bollards and tyre killer
-
-
-
... More
I st year
1
-
-
... More
II nd year
1
-
-
... More
Sub Head - II : Repair and Painting Works
AMC of 250 KWp terrace mounted Solar panels along with inverter and other accessories as complete(Faulty spares will be provided by AAI).
-
-
-
... More
I st year
1
-
-
... More
II nd year
1
-
-
... More
Sub Head - II : Repair and Painting Works
Decorating City side of Airport with minimum 50 nos PAR Lights , 300 nos Led Rice lights , 20 nos flood lights giving tri colour effects or as per theme dicided by E-I-C during national holidays or festivals.
-
-
-
... More
I st year
7
-
-
... More
II nd year
7
-
-
... More
Sub Head - II : Repair and Painting Works
Servicing, maintenance and testing of L & T make Air Circuit Breaker - 1250/1000/800/630A FP, EDO complete as required.
-
-
-
... More
I st year
24
-
-
... More
II nd year
24
-
-
... More
Sub Head - II : Repair and Painting Works
Servicing, maintenance and testing of L & T make Air Circuit Breaker - 2500 A, FP, EDO complete as required.
-
-
-
... More
I st year
7
-
-
... More
II nd year
7
-
-
... More
Sub Head - II : Repair and Painting Works
Servicing, maintenance and calibration of earth fault and over load relay with secondary injection kit etc. of 05 nos. HT panel complete as required.
-
-
-
... More
I st year
7
-
-
... More
II nd year
7
-
-
... More
Sub Head - II : Repair and Painting Works
Servicing, maintenance and testing of 33 kV HT - Vaccum Circuit Breaker of Siemens make etc. complete as required.
-
-
-
... More
I st year
7
-
-
... More
II nd year
7
-
-
... More
Sub Head - II : Repair and Painting Works
Testing of BDV value of transformer oil at site as per direction of EIC
10
-
-
... More
Sub Head - II : Repair and Painting Works
Dehydration and filtration of transformer oil at site including testing for BDV before and after dehydration and filtration and submission of test reports etc. as required for power Transformers
-
-
-
... More
I st year
4000
-
-
... More
II nd year
4000
-
-
... More
Sub Head - II : Repair and Painting Works
Rewinding the following with copper winding wires of required size and heat varnishing etc. as required including less for dismantled copper wire etc. as and when required.
-
-
-
... More
Ceiling fans upto 1400 mm
20
-
-
... More
Exhaust fans upto 450 mm
10
-
-
... More
Wall Fans
10
-
-
... More
Replacement of ball bearing for above fans.
20
-
-
... More
Sub Head - II : Repair and Painting Works
Shortening height of Perimeter Light Poles at various location complete in all respect and as per instruction of EIC
75
-
-
... More
Sub Head - II : Repair and Painting Works
Providing and fixing vinyl sticker on the existing information signage board inside NITB of required design and letters. The letters in Hindi and English will be electro cut computerised automated to be transferred on existing polycarbonate sheet after removing the existing vinyl sticker complete as directed by engineer-in -charge as and when required.
10
-
-
... More
Sub Head - II : Repair and Painting Works
Painting of Fire fighting equipments i.e. Pumps, Hose cabinets, Pipes etc. with two coats of red synthetic enemel paint as approved by engineer-in-charge after scrubbing and cleaning the old paint from the existing surface.
80
-
-
... More
Sub Head - II : Repair and Painting Works
Painting of Street light Poles of height more than 7 m and upto 9 m with one coat of primer and two coats of approved alumminium paint after scrubbing and cleaning the old paint complete from the existng surface.
120
-
-
... More
Sub Head - II : Repair and Painting Works
Painting of checkered plate/ Earth pit cover with two coat of black enamel paint after scrubbing and cleaning the old paint complete from the existng surface.
50
-
-
... More
Sub Head - II : Repair and Painting Works
Lettering of maximum 2" size (Alpha/ Numerical) on the existing surface of feeder pillar / panel/ earth pits with synthetic enamel paint of approved colour as approved by engineer-in-charge etc. as required.
1000
-
-
... More
Sub Head - II : Repair and Painting Works
Lifting and lowering of Underground Submersible Pump Motor set upto 5 HP installed at various locations at airport colony.
4
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of Spring charging motor with gearbox suitable for L&T make U-Power FP ACB of rating 800A/1000A/1250A/2500A.
4
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of box type heavy duty capacitor of following rating suitable to work on 3 phase, 440 V, 50 Hz AC supply.
-
-
-
... More
5 kVAR
5
-
-
... More
10 kVAR
5
-
-
... More
25 kVAR
4
-
-
... More
50 kVAR
3
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of Shunt release coil for L&T make U-Power FP ACB of raring 1250/ 2500 A.
2
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of heavy duty SMF battery of following rating :-
-
-
-
... More
12V, 100 AH. Exide XP or equivalent
2
-
-
... More
12V, 180 AH. Exide XP or equivalent
4
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts Conforming to IS: 694.
-
-
-
... More
1.5 sqmm.
1200
-
-
... More
2.5 sqmm.
1200
-
-
... More
4.0 sqmm.
1200
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of Safety shutter for 4P U-power ACBs of 2500A rating.
4
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of medium intensity obstruction light as per latest ICAO specification
6
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of transformer oil.as per latest government specifications for power transformer.
400
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of syubmersible pump of 3 hp make KSB model UMAI or equivalent
2
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of submersible pump of 5 HP make KSB model UMAI or equivalent
1
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of table solar fan minimum 16 w, upto 1300 rpm, fan diameter minimum 35.00 cm at all Security booths situated along the perimeter road
12
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of wall mounted 300 mm sweep fan suitable to work on single phase, 230V, 50 Hz AC supply.
4
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of heavy duty exhaust fan of following size having 1400 RPM suitable to work on single phase, 230V, 50 Hz AC supply :-
-
-
-
... More
(a) 300 mm
10
-
-
... More
(b) 450 mm
10
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of 400 mm sweep pedestrail fan suitable to work on single phase, 230V, 50 Hz AC supply.
4
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Procurement of Street Lights of 70W.
-
-
-
... More
(i) Strip
30
-
-
... More
(ii) Driver
30
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of Legrand Myrius 673044 6A 5 Pin White Universal Sockets with safety Shuter
10
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of 6A/16A, Uni Socket.
20
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of 6A/13A Combine Socket (For All Kind Of Pins).
50
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of white 1M Modular Combined Plate.
20
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of white 2M Modular Combined Plate.
20
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of white 3M Modular Combined Plate.
50
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of 6A, Bell Push Switch.
20
-
-
... More
Sub Head - III : Supply of Material (As and when required )
Supply of 20 W, tube fittings suitable to operate on single phase, 230V, 50 Hz AC supply.
200
-
-
... More
Sub Head - IV DSR Works
Percentage above or below on the rates of DSR'2018 (CPWD)-Electrical items worth totaling to Rs.5,00,000.00 as per requirement.
(Note: The firm has to quote/upload the Percentage above/ below (+/- %) on the quantity mentioned against this item directly in the form of multiplying factor in the rate coloumn as clarified below:
For Example: If desired to quote 5% above on SR-2018 rates, the rate column shall be filled as 1.05. If desired to quote 3% below on SR-2018 rates, the rate column shall be filled as 0.97.)
1
-
-
Evaluation Notes How It Works ?