University Of Jammu Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
University Of Jammu Tender
Electrical and Electronics
Eprocure
Opening Date22 Feb 2024
Closing Date27 Feb 2024
Tender Amount₹ 2,00,000
Costs
EMD
₹ 4,000Document Cost
₹ 590Tender Fee
Refer Documents
Summary
Repair Of Over Head External Ht Lt Network And Substation At New University Campus 2023 24
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UDJK_245567_1Bid Award Id
ViewTender No
enit 972 dated 22-02-2024 3rd callTender Authority
University Of Jammu ViewPurchaser Address
-Website
http://http://jammuuniversity.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Erection of metallic pole of following length in cement concrete 1:3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc. as required. Above 8 meter upto 11 meter
2
14154
7077
Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required
96
19488
203
Supply and erection of three piece non linear resistor type lightning arrestor suitable for 3-wire 11 kv overload lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement,G.I bolts,nuts washers etc as reqd
1
2628
2628
Supply and erection of galvanized ‘D’ iron clamps complete with shackle insulator (100 mm x 110 mm), G.I bolts, nuts and washers, coach screws etc. as required.
10
2980
298
Supply and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts washers etc as reqd.
10
3120
312
Non-Schedule Items Painting of previously painted swaged type Tubular poles of following size with silver paint (One or more coat) of approved brand and manufacture.
Make (Asian/Nerolac) a) 4.0 mtr height
40
10000
250
b) 8.0 mtr height
50
25000
500
c) 9.0 mtr height
50
27500
550
Supply of following size ACSR conductor of required aluminum and steel strands including binding etc. as required as per IS O 398 part 2
7/2.11 mm to 7/4 mm
100
15000
150
Rewinding of 250 to 630 KVA rating of Distribution transformers with suitable size HV/LV leg new coil made of Aluminium Super Enamel Coil/DPC as per the requirement of original existing winding including painting the transformer with weather proof paint of approved brand as per IS code.
33
9405
285
Rewinding of 250 to 630 KVA rating of Distribution transformers with suitable size HV/LV New leg coil made of Copper Super Enamel Coil/DPC as per the requirement of original existing winding including painting the transformer with weather proof paint of approved brand as per IS code.
35
43750
1250
S/Filling of Filtered Dehydrated Transformer oil.
50
4000
80
Filtration and Dehydration of the existing Transformer Oil including filling in the repaired transformer
50
1750
35