University Of Jammu Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

University Of Jammu Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date9 Aug 2024
Closing Date30 Aug 2024
Tender Amount₹ 24,65,000 
Notes
Download

Costs

Summary

Up Gradation Of Centre For Career Planning And Counseling (ccpc) Building For Proposed Residential Coaching Academy (rca) Phase-1st At Main Campus

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Up gradation of Centre for Career Planning and Counseling (CCPC) Building for proposed Residential Coaching Academy (RCA) Phase-1st at Main Campus
Up gradation of Centre for Career Planning and Counseling (CCPC) Building for proposed Residential Coaching Academy (RCA) Phase-1st at Main Campus
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
FORMWORK Providing and fixing to correct level, line plum, vertical, plain formwork with contractors own material in all shapes made of plywood/MS sheets for RCC/PCC works including necessary strutting,scafffolding, bracing etc. leaving necessary recesses, opening chamfers etc. keeping the same in position during concreting and removing after the specified period all complete after as per specification and direction of EIC. For BFGL & AFGL mass concrete.

53.52

15325

286.35

... More
Providing and laying gang saw cut of specified thickness, mirror polished pre-moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of requiredsize and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in Charge.18mm thick

14.43

59631

4132.45

... More
15mm thick cement plaster on brick / concrete wall of mix 1:4 (1cement: 6 coarse sand)

7.5

2295

306

... More
PLASTIC EMULSION PAINT Painting, two or more coats with Dulux paint of Spectrum / Nerolac or Equivalent make and approved shade on internal walls and ceilingsasrequired to give an even shade including preparing the surface, etc. complete all to the satisfaction of EIC.

1158.91

162247

140

... More
STUDY TABLE :TABLE TOP: The workstation top shall be made of 25mm thick prelaminated particle board of size 1800x1200x750mm (As per IS: 12823). Bottom of the worktop shall have a backing laminate of minimum 0.6mm thickness. All the edges of work surface shall be provided with machine pressed 2 mm thick PVC Edge band glued with hotmelt EVA glue to maintain softness and flexibility, clarity and gloss, barrier properties, low-temperature toughness, and resistance to UV radiation. The worktop should be supported by a worksurface bracket made up of 2.0 mm thick CRCA grade D steel as per IS : 513-19 Partition Systems:- Providing and fixing of panel based System of 50-60 mm thick of 1050-1100mm height. The panel should comprise of vertical and horizontal extrusions of aluminum having material AL96063-T6 and should have average wall thickness of 1.2 mm & powder coated with epoxy-polyester powder with average 50 to 60 micron thickness. Bottom frame for panel should comprise of L- Channels made of 2mm thick CRCA steel (IS:513), formed plates of 3mm thick HR steel (IS:2062) & ERW steel tube of size 35x15x1.6mm in oval cross section (IS:7138) welded together. The same shall have to be bolted to the uprights with suitable screws.The panel should be supported on legs 120-130mm high fabricated out of MS Tube of section of size between 30 to 40mm of minimum thickness of 1.5mm(IS: 7138 ERW Tube) with the base plate of the MS plate as per tube size over which a Leveler shall be fitted, which allows for adjustment of the height upto 50mm. The top and end trims should be powder coated aluminium slide fitted with the help of end trim connectors. All 2 way, 3 way and 4 ways junction to be covered with die cast aluminum caps having material AL96063-T6 and should have average wall thickness of 1.2 mm. Wire Management : The cables shall come from Ground in a concealed conduit / raceway . System offered should have provision to provide the switch cut outs on the top tile above the worktop or on the bottom tile of the panel. 8 module (including 2 plug) and 6 module with lan to be fitted either above worktop or below. The product quoted should be BIFMA level 3 certified. BLOCKS : The block for panel’s shall comprise of 35-40 mm thick paper honeycomb or any other filler for compressed strength with 3-6mm MDF on each sides and 0.6mm decorative laminate or fabric on both sides. Particle board framing shall be used on outer boundary of these blocks as well as intermediately at certain locations forming conduit for passing cables. The blocks should be fixed into the supporting frame befor fixing of the horizontal and vertical trims which should not be used as structural members.The top panels should be offered in fabric , fabric tackable , metal, white board . Fabric shall be upholtered with zero VOC content glue as per drawing with fabric of approved quality. White board tiles shall be made of 8.0 mm thick particle board conforming to IS: 12823 laminated with 0.6mm thick white glossy high pressure laminate on outer side with 0.6mm backing laminate on inner surface and will be having all its edges with minimum 0.5 mm thick PVC edging.The Panel between 2 adjacent seats shall be made up of 20-30mm thickness. These intermediate panels shall be offered in fabric , fabric tackable ,metal or as desired by Engineer - in - charge.The bottom panel shall be metal with provision of passing cables and cutouts for switch boxes at suitable locations to the satisfaction of the Engineer - in - charge. The product quoted should be BIFMA level 3 certified

15

780000

52000

... More
CHAIR.The overall dimensions of the chair shall be 60.9cm x 64.3cm x 99.6cm. The seat height shall be 44.8cm. The cushioned seat and back is made of injection moulded Plastic outer and Inner. Plaster inner is upholstered with stitched cover and moulded high Resilience Polyurethane foam of density 45kg per meter cube. The stitched cover is made from spacer fabric and leatherette. Seat size shall be 47cm x 48cm. The Back size shall be 45cm x 60.5cm. The armrests top is moulded from PU and mounted on to a drop lift adjustment type tubular armrest support made of 3.8cm diameter x 0.2cm thick MS ERW tube. The tubular frame shall be powder coated DFT 40-60 microns and is cantilever type and made of 2.54cm X 0.2cm thick MS ERW tube. The back is connect to frame through powder coated high pressure die cast connector piece. The product must be either Greenguard or Bifma Level or IAQ or Griha certified. The certificate must be attached along with the technical bid. The certificate must mention the manufacturer's name as well as Model name. The certificate must be from an authorised issuing agency only. The certificate must be verifiable from the valid issuer's website.

46

621000

13500

... More
Finishing with Apex paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete on all surfaces.

1516.5

212310

140

... More
Removing and fixing of GLAZING / FACADE WORKS CURTAIN GLAZING SYSTEM Removing & refixing of curatain glazing system double glazed hermetically sealed glazing with 6 mm thick clear toughened glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. smoke seal for floor to floor separation at all levels including cost of scoffolding.

20.88

30276

1450

... More
GLAZING / FACADE WORKS CURTAIN GLAZING SYSTEM Providing and fixing of Facade glazing following Stick curtain wall system will include double glazed hermetically sealed glazing with 6 mm thick clear toughened glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. smoke seal for floor to floor separation , Colour of glass to be clear / neutral / grey / blue as approved. Make Asahi/Saint Gobain or equivalent.

20.88

114840

5500

... More
Providing and fixing Aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia. and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, dashfastners, handles, hinges, all complete as per architectural drawings and the directions of Engineer-in-charge. (including Glazing, paneling, sliding channels/ sliding arrangement and other fittings complete)Powder coated aluminum (minimum thickness of powder coating 50 micron) Using 4"x2" sections 1.5mm thick

76.14

418770

5500

... More
Note. The quoted percentage (%age) should preferably be in fractional form in order to minimize concurrence of similar quoted rates

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.