Tourism Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Tourism Department Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date2 Dec 2024
Closing Soon9 Dec 2024
Tender Amount₹ 10,00,000 
Notes
Download

Costs

Summary

Stage Contract For Emergency Electrical Works At Rsgc Srinagar

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply ,Installation ,testing and commissioning of Single CORE 120 MM2 ARMOURED CABLE ALUMINIUM make Havells, RR,Polycab

80

380

30400

... More
Servicing of 50 Litre Water Heater (Geyser) including the cost of Repair/ new Spares.

10

2200

22000

... More
SITC of boom barrier Arm 6 Meter Long as per Sample.

1

25000

25000

... More
1. Supply, Installation, Testing and Commissioning of inverter type , 4 to 5 star or better rating air conditioner of capacity = 1.5 TON or better HOT and COLD Split Air conditioners with cordless remote control unit, R32 refrigerant suitable for 230V/ 1Phase / 50Hz (Capable of functioning plausibly in outdoor ambient temperature of -10 to 46 degree in cooling & -15 to 24 degree in heating with all features like cooling & heating mode, On-Off Timer, ECO Hi -Power, Swing & fix Louver, Noiseless below 54 db (Outdoor)) The scope includes suction line ,liquid line of copper tubing with requisite insulation and allied fittings for connecting outdoor unit with indoor one complete plus pre-fabricated mild steel stands duly both primer and metal paint coated. The scope also includes grouting in the slab etc so as to secure the unit firmly with MS clamps complete with nuts ,bolts ,washers etc galvanised /painted for hanging of outdoor units from slopping roof beams etc as per site requirement with proper dressing of drilled /grouted works etc and all other allied accessories, compete job

3

85000

255000

... More
Supply installation testing and commissioning of micro controller based copper wound digital 5 KVA voltage stabilizer for automatic operation ,single phase naturally air cooled indoor type wall mounted with input range 150-250 V and output voltage 230 V +/- 5% With surge protection, under/overvoltage protection, smart time delay and digital display of a reputed make such as V-Guard.. Stabilizers should have a three year replacement warranty.

3

9000

27000

... More
Supply, Installation, testing and Commissioning of 32A, 240V SPN industrial type socket outlet with 2 pole and earth, metal enclosed plug top along with 20A. “C” curve SP MCB in sheet steel enclosure on surface or in recess with chained metal cover for the socket out let Make Legrand, Havells or equivalent.

3

1700

5100

... More
Supply of 2.5 sqmm multistranded copper wire, FRS, PVC insulated, 1100 Volts (Havells/ Polycab or eq. make)

360

45

16200

... More
Supply of 1.5 sqmm multistranded copper wire, FRS, PVC insulated, 1100 Volts (Havells/ Polycab or eq. make)

360

35

12600

... More
Supply of 4 sqmm multistranded copper wire, FRS, PVC insulated, 1100 Volts (Havells/ Polycab or eq. make)

360

70

25200

... More
Supply LED Post Top Luminaire 27 Watt, 220-240 Volt, IP 65, Neutral White, matching the exiting luminaires installed in the Golf Course. Philips/Havells or equivalent.

5

23000

115000

... More
Supply Installation testing comissioning of Integral LED floodlight having system wattage of 195W to 200W. The luminaire shall be made of pressure die-cast aluminum alloy (ADC12) with separate control gear compartment. The luminaire shall be able to deliver minimum 24100 Lumens with system efficacy of ≥ 123lm/w. The brand name shall be embossed on the luminaire & shall not be screen printed or put using stickers. The LEDs used shall have CCT 5700°K, CR≥70, SDCM≤5 & life of 50000Hrs @ L70B50. The luminaire shall be IP66 & IK08 compliant. The control gear compartment shall be accessible from the back of the luminaire. The luminaire shall have Class B serviceability. The luminaire shall have Anti Dust Exposed Lenses as front cover which shall ensure IP rating for the serviceable life. The luminaire shall be available with following beam angle Asymmetric Wide Beam angle (Horizontal Beam-54.5°, Vertical Beam-15°), Asymmetrical Medium Beam (Horizontal Beam-69.8°, Vertical Beam-34.8°), Narrow Beam (Horizontal Beam-12°, Vertical Beam-11.3°) & Symmetric Wide Beam (Horizontal Beam-77.3°, Vertical Beam-22.1°) The luminaire shall use 0-10V Dimmable Potted driver (Ashphalt Potting/Mixture of Ashphalt & Silicon Potting) having THD≤ 10% (@ full load), PF≥ 0.95 (@full load), Phase-to-Phase 440V protection for 8 Hrs, High Voltage cut-off @ 325V (±15V), Low voltage cut-off ≤ 90V, Auto-Restart, Operating voltage of 12l40V to 270V, In-built Surge Protection of 4KV (CM & DM), Should be able to sustain 320V for 48 Hrs. The driver shall be tested as per IEC61347-2-13 & IEC 62384. The LED driver shall be BIS registered. The luminaire shall have 10KV/5KA SPD placed in-side the control gear box of the luminaire. The luminaire shall be fitted with U -Bracket with Aiming scale. The minimum luminaire dimensions shall be W: 536mm (Housing only), H: 243MM (housing only) & Depth: 62MM (with Fins). The nominal weight of the luminaire shall be 7Kgs with Max. projected area as 0.14Sq.m. The luminaire driver & it’s SPD shall be of the same make/manufacturer/Lighting company as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, "FAT"

4

12500

50000

... More
Supply of 9-12 Watt LED Lamps (Havells/Philips/eq.)

100

195

19500

... More
PVC Insulation Tape Rolls

100

20

2000

... More
PTC Fan Heater Blower with Adjustable Thermostat 1000 to 2000 Watt (Havells/Usha/Warmex/eq. make)

3

5000

15000

... More
Providing, fixing and testing of LED decoration ropes (Zool) for decoration of buildings, gate, office and other allied areas of RSGC along with the required electric wiring on daily rental basis as and when required.

15000

13

195000

... More
Supply of Distilled Water for batteries

50

25

1250



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.