Srinagar Smart City Limited Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Srinagar Smart City Limited Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date7 Feb 2022
Closing DateCancelled
Tender Amount₹ 21,60,00,000
Costs
EMD
₹ 43,20,000Document Cost
₹ 20,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_SSC_159706_1Bid Award Id
ViewTender No
E-N.I.T NO. 04-SSCL OF 02-2022 DT. 07-02-2022Tender Authority
Srinagar Smart City Limited ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
SBD for Conversion of Overhead Electrical Network into Underground Cabling with Compact Sub-Stations at Jhelum River Front
BOQ Items
Supply, Laying, installation testing,and commissioning including labour, carriage, freight, taxes, duties etc. of 11kV, Single core 300 mm2 Aluminium round wire Armoured XLPE Cable , FRLS (With Three spare cables-One circuit for Main and One circuit Spare-Total 6 Runs) in cable duct bank alongwith 4" HDPE pipe for 2.05 km (Single run) for Communication and other Non Electrical lines in proper dressing of the cable in an approved manner, complete as required, as per guidelines, detailed JKPDD Specifications and as per direction of Engineer Incharge.The item includes providing of necessary clamps and hardware for cable laying.
13
-
-
Supply, Laying, installation testing,and commissioning including labour, carriage, freight, taxes, duties etc. of 11kV, Single core 120 mm2 Aluminium round wire Armoured XLPE Cable , FRLS (With Three spare cables-One circuit for Main and One circuit Spare-Total 6 Runs) in cable duct bank alongwith 4" HDPE pipe for 1.10 km (Single run) for Communication and other Non Electrical lines in proper dressing of the cable in an approved manner, complete as required, as per guidelines, detailed JKPDD Specifications and as per direction of Engineer Incharge.The item includes providing of necessary clamps and hardware for cable laying.
7
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Straight Through Joints : Heat Shrinkable type single core H.T. Cable straight Through Joints along with boots (SILCAB - T) to accommodate following size of 11 KV XLPE(E) aluminium cable size 400, 300, 185, 240 & 120 mm2 complete with all kit contents including earth continuity connection along with 3 Nos. Crimping type aluminium lugs/thimbles of suitable capacity incluiding making joints etc.in an approved manner complete as required & as per KPDD Specification.
74
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of brass Route marker as per standard specifications and approved design along the cable/cable duct bank in complete manner as required.
88
-
-
Supply, Laying, Testing & Commissioning of Cable Termination Kits (indoor/outdoor) : Heat Shrinkable type (Indoor/Outdoor) termination along with necessary accessories to accommodate for armoured 400, 300, 120, 75/50 mm2, 11 Kv (XLPE(E) aliuminum cable complete with all kit contents including earth continuity along with 3 Nos. crimping type aluminium lugs of suitable capacity including making joints etc. in an approved manner complete as required & as per KPDD Specification.
45
-
-
Supply, Laying, Testing & Commissioning of warning Tap in complete manner as per required .
8
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Earthing Complete
Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of GI pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 50 mmx6 mm for connection of rmu body as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover as per KPDD Specification.
14
-
-
4 Way RMU Works:
-
-
-
Supply, Errection,testing and commissioning of 11 kV, 1 core (6 runs) 75/50 sq.mm, Al conductor,XLPE, insulated, armoured cable (from the RMU to the transformer).The item includes providing of necessary clamps and hardware for cable laying.
140
-
-
Supply,installation,testing and commissioning of 11 kV, Ring Main Unit ,SF6 Insulated, out-door type, Extensible type,breaking capacity 25 KA for five seconds with SF6 circuit breaker / VCB self powered with O/C + E/F Relay comprising of :- a) 11kV 630 Amp Motorised isolator including earthing Switches with making capacity 52kA, having mechanical ON/OFF, earth indications with fault current Indicator.
b) 11kV ,200 Amp motorised Spring operated, Circuit breakers with earthing switches, connecting the RMU to Supply transformer. c).Copper Bus Bar of 630 Amp rating.
d). 1 No Numerical Aux. Powered relay having non directional O/C and E/F protection (for each ciruit breaker).
d). The Circuit Breaker enclosures shall be outfitted with a communicable-type numerical (feeder protection) relay, i.e., one for each circuit breaker. The relay shall also interface via an RS 485 port in order to send, as a minimum, real-time phase current , readings using the MODBUS protocol.
e) Incomming Isolator having FPI with eclectrical reset Contact /facility with O/C, E/F protection.
f) All necessary Potential free contacts for indications relevent to RMU monitoring and control.
g) Capacitor voltage dividers serving Live-Line Cable indicators in each breaker and Isolator. CBCT with O/C, E/F relay. RMU must be SCADA enabled with interlocking arrangement between LBS and TCB.
7
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Providing of portable tool kits complete with T&P and safety items.
6
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Providing of prefab HT inspection boxes/ inspection windows made out of GI (epoxy) sheet , 4mm thick with nessary material in repect of all manners.
30
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of fault detection machine (mobile/vehicle type), as per specifications, for detection of HT as well as LT cable faults.
1
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Earthing of RMU : Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of GI pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 50 mmx6 mm for connection of rmu body as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover as per KPDD Specification
7
-
-
LT Underground Cabling Works:
-
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Channel iron Frame mounted L.T Distribution Box for the DT`s with the following switchgears & other necessary accessories & inbuilt padlocking facility, etc. required to complete the job as per specification. INCOMING : 2 No ACB's 630A each microprocessor based with O/C, E/F relays, 4P, 25KA MCCB with T/M release with following accessories: Multifunction BUSBARS: 4 Pole, Alum. With heat shrinkable sleeves in following capacities:.1200 A, 433V, 50Hz.25KA, 4 Strips, Aluminium with heat shrinkable sleeves. OUTGOINGS: 1. 400A, 4Pole MCCB-25KA with T/M protection - 1 Set, 2. 400A, 4Pole MCCB-25KA with T/M protection - 2 Sets, 3. 3 Phase 4 Wire energy meter- 3 nos. (4 DB per DT)
12
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Channel iron Frame mounted L.T Distribution Box for the DT`s with the following switchgears & other necessary accessories & inbuilt padlocking facility, etc. required to complete the job as per specification. INCOMING : 2 No ACB's 630A each microprocessor based with O/C, E/F relays, 4P, 25KA MCCB with T/M release with following accessories: Multifunction BUSBARS: 4 Pole, Alum. With heat shrinkable sleeves in following capacities:.1200A, 433V, 50Hz.25KA, 4 Strips, Aluminium with heat shrinkable sleeves. OUTGOINGS: 1. 400A, 4Pole MCCB-25KA with T/M protection - 1 Set, 2. 400A, 4Pole MCCB-25KA with T/M protection - 2 Sets, 3. 3 Phase 4 Wire energy meter- 3 nos. (3 DB per DT)
12
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Channel iron Frame mounted L.T Distribution Box for the DT`s with the following switchgears & other necessary accessories & inbuilt padlocking facility, etc. required to complete the job as per specification. INCOMING : 1 ACB 630A microprocessor based with O/C, E/F relays, 4P, 25KA MCCB with T/M release with following accessories: Multifunction BUSBARS: 4 Pole, Alum. With heat shrinkable sleeves in following capacities:.630 A, 433V, 50Hz.25KA, 4 Strips, Aluminium with heat shrinkable sleeves. OUTGOINGS: 1. 400A, 4Pole MCCB-25KA with T/M protection - 1 Set, 2. 400A, 4Pole MCCB-25KA with T/M protection - 2 Sets, 3. 3 Phase 4 Wire energy meter- 3 nos. (3 DB per DT)
15
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Channel iron Frame mounted L.T Distribution Box for the DT`s with the following switchgears & other necessary accessories & inbuilt padlocking facility, etc. required to complete the job as per specification. INCOMING : 400 A, 4P, 25KA MCCB with T/M release with following accessories: Multifunction BUSBARS: 4 Pole, Alum. With heat shrinkable sleeves in following capacities: 630A/400 A, 433V, 50Hz.25KA, 4 Strips, Aluminium with heat shrinkable sleeves. OUTGOINGS: 1. 400A, 4Pole MCCB-25KA with T/M protection - 1 Set, 2. 400A, 4Pole MCCB-25KA with T/M protection - 2 Sets, 3. 3 Phase 4 Wire energy meter- 3 nos. (2 DB per DT)
12
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Channel iron Frame mounted L.T Distribution Box for the DT`s with the following switchgears & other necessary accessories & inbuilt padlocking facility, etc. required to complete the job as per specification. INCOMING : 200 A, 4P, 25KA MCCB with T/M release with following accessories: Multifunction BUSBARS: 4 Pole, Alum. With heat shrinkable sleeves in following capacities: 400A/200 A, 433V, 50Hz.25KA, 4 Strips, Aluminium with heat shrinkable sleeves. OUTGOINGS: 1. 400A, 4Pole MCCB-25KA with T/M protection - 1 Set, 2. 400A, 4Pole MCCB-25KA with T/M protection - 2 Sets, 3. 3 Phase 4 Wire energy meter- 3 nos. (1 DB per DT)
3
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 3 phase 4 wire SMART energy meter, as per specifications.
543
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 1 phase 2 wire smart energy meter, as per specifications.
980
-
-
Supply,Laying,installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 400 mm² Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type (With one spare cable-Total 5 Runs) working voltage upto 11000 volt to be laid in cable duct with necessary connection in an approved manner complete as required & as per instructions, guidelines, detailed JKPDD Specifications as per direction of Engineer Incharge.The item includes providing of necessary clamps and hardware for cable laying.
10
-
-
Supply,Laying, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 300 mm² Single Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type (With one spare cable-Total 5 Runs) working voltage upto 11000 volt to be laid in cable duct with necessary connection in an approved manner complete as required & as per instructions, guidelines, detailed JKPDD Specifications as per direction of Engineer Incharge.The item includes providing of necessary clamps and hardware for cable laying.
41
-
-
Supply,Laying, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 150 mm² Single Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type (With one spare cable-Total 5 Runs) working voltage upto 11000 volt to be laid in cable duct with necessary connection in an approved manner complete as required & as per instructions, guidelines, detailed JKPDD Specifications as per direction of Engineer Incharge.The item includes providing of necessary clamps and hardware for cable laying.
3
-
-
Supply,Laying, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 95/85 mm² Single Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type (With one spare cable-Total 5 Runs) working voltage upto 11000 volt to be laid in cable duct with necessary connection in an approved manner complete as required & as per instructions, guidelines, detailed JKPDD Specifications as per direction of Engineer Incharge.The item includes providing of necessary clamps and hardware for cable laying.
1
-
-
Supply,Laying, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 75/35 mm² Single Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type (With one spare cable-Total 5 Runs) working voltage upto 11000 volt to be laid in cable duct with necessary connection in an approved manner complete as required & as per instructions, guidelines, detailed JKPDD Specifications as per direction of Engineer Incharge.The item includes providing of necessary clamps and hardware for cable laying.
6
-
-
Supply,Laying, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 25 mm² 2-Core Cable,armoured, service line, XLPE Insulated Stranded Conductor FRLS type.
26
-
-
Supply,Laying, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 16 mm² 2-Core Cable,armoured, service line, XLPE Insulated Stranded Conductor FRLS type.
8
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Straight Through Joints for cables.
Heat Shrinkable type Straight Through Joints along with necessary accessories to accommodate for Three core & single core 400,300,150,95/85,75/35 mm2, 1100 Volt, XLPE(E) aliuminum cable complete with all kit contents including earth continuity of suitable capacity including making joints etc. in an approved manner complete as required.
238
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Cable Termination Kits (indoor/outdoor). Heat Shrinkable type (Indoor/Outdoor) termination along with necessary accessories to accommodate for single core 400,300,150,95/85,75/35 mm2, XLPE(E) aliuminum cable complete with all kit contents including earth continuity along with 3 Nos. crimping type aluminium lugs of suitable capacity including making joints etc. in an approved manner complete as required.
139
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of brass Route marker of standard design and specifications along the cable/cable trench in complete manner as per required.
124
-
-
Supply, Laying, Testing & Commissioning of warning Tap in complete manner as per required
12
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Earthing Complete
Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of GI pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 50 mmx6 mm for connection of rmu body as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover as per KPDD Specification.
60
-
-
Compact Substation Work:
-
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc.
Packaged Substation - 1MVA: Supply, Erection on existing C.C. foundation, Testing &Commissioning of 11kV Outdoor type Package Sub-Station consisting of 11/0.433kV, 1MVA Oil type transformer, MV panel, LT panel inside GI sheet steel /Metallised Epoxy enclosure with interconnections, fully type tested as per the IEC-1330 complete in all respect each consisting of following items & as per detailed technical specifications: A) 3way Non - Extensible unit RMU with 2no. 1000 A load break switch & 1 no. 1000A tee off with SF6 circuit breaker / VCB self powered with O/C + E.F. Relay, M.V Metering arrangement with digital electronic meter, C.T' etc. complete as required to entire satisfaction of Engineer-in-charge. B) 1 no. 11 kV / 433V, 630 KVA three phase, DYN11, +5% to - 5% in steps of 2.5% at line end of HT side , off lead tap, oil cooled type transformer with Cu winding and standard fittings C) 1 No. 433V, 300A LT devices with PVC sleeved Aluminium busbars. D) One no. 4pole 1000A, 25kA MCCB with microprocessor Based Release. E) Adequate compartment to accommodate Five nos. Four Pole MCCBs of maximum capacities of 400Amp. each including 3-phase 4 wire energy meter F) The provision for solid connection with aluminium strips with heat shrinkable sleeves from Main L.T Bus bar to each compartment of MCCB so as to enable the executing agency at site for connection with MCCB.
All as per KPDD Specification
3
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc.
Packaged Substation - 630 kVA: Supply, Erection on existing C.C. foundation, Testing &Commissioning of 11kV Outdoor type Package Sub-Station consisting of 11/0.433kV, 630 kVA Oil type transformer, MV panel, LT panel inside GI sheet steel /Metallised Epoxy enclosure with interconnections, fully type tested as per the IEC-1330 complete in all respect each consisting of following items & as per detailed technical specifications: A) 3way Non - Extensible unit RMU with 2no. 1000 A load break switch & 1 no. 1000 A tee off with SF6 circuit breaker / VCB self powered with O/C + E.F. Relay, M.V Metering arrangement with digital electronic meter, C.T' etc. to complete as required to entire satisfaction of Engineer-in-charge. B) 1 no. 11 kV / 433V, 630KVA three phase, DYN11, +5% to - 5% in steps of 2.5% at line end of HT side , off lead tap, oil cooled type transformer with Cu winding and standard fittings. C) 1 No. 433V, 300A LT devices with PVC sleeved Aluminium busbars. D) One no. 4pole 1000A, 25kA MCCB with microprocessor Based Release. E) Adequate compartment to accommodate Five nos. Four Pole MCCBs of maximum capacities of 400Amp. each Including energy meter F) The provision for solid connection with aluminium strips with heat shrinkable sleeves from Main L.T Bus bar to each compartment of MCCB so as to enable the executing agency at site for connection with MCCB. All as per KPDD Specification
4
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc.
Packaged Substation - 400 kVA: Supply, Erection on existing C.C. foundation, Testing &Commissioning of 11kV Outdoor type Package Sub-Station consisting of 11/0.433kV, 400 kVA Oil type transformer, MV panel, LT panel inside GI sheet steel /Metallised Epoxy enclosure with interconnections, fully type tested as per the IEC-1330 complete in all respect each consisting of following items & as per detailed technical specifications: A) 3way Non - Extensible unit RMU with 2no. 600 A load break switch & 1 no. 600A tee off with SF6 circuit breaker / VCB self powered with O/C + E.F. Relay, M.V Metering arrangement with digital electronic meter, C.T' etc. to complete as required to entire satisfaction of Engineer-in-charge. B) 1 no. 11 kV / 433V, 400 KVA three phase, DYN11, +5% to - 5% in steps of 2.5% at line end of HT side , off lead tap, oil cooled type transformer with Cu winding and standard fittings C) 1 No. 433V, 600A LT devices with PVC sleeved Aluminium busbars. D) One no. 4pole 1000A, 25kA MCCB with microprocessor Based Release. E) Adequate compartment to accommodate Five nos. Four Pole MCCBs of maximum capacities of 400Amp. each including energy meter F) The provision for solid connection with aluminium strips with heat shrinkable sleeves from Main L.T Bus bar to each compartment of MCCB so as to enable the executing agency at site for connection with MCCB. All as per KPDD Specification
5
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc.
Packaged Substation - 250 kVA: Supply, Erection on existing C.C. foundation, Testing &Commissioning of 11kV Outdoor type Package Sub-Station consisting of 11/0.433kV, 250 kVA Oil type transformer, MV panel, LT panel inside GI sheet steel /Metallised Epoxy enclosure with interconnections, fully type tested as per the IEC-1330 complete in all respect each consisting of following items & as per detailed technical specifications: A) 3way Non - Extensible unit RMU with 2no. 400 A load break switch & 1 no. 400A tee off with SF6 circuit breaker / VCB self powered with O/C + E.F. Relay, M.V Metering arrangement with digital electronic meter, C.T' etc. to complete as required to entire satisfaction of Engineer-in-charge. B) 1 no. 11 kV / 433V, 250 KVA three phase, DYN11, +5% to - 5% in steps of 2.5% at line end of HT side , off lead tap, oil cooled type transformer with Cu winding and standard fittings C) 1 No. 433V, 400A LT devices with PVC sleeved Aluminium busbars. D) One no. 4pole 1000A, 25kA MCCB with microprocessor Based Release. E) Adequate compartment to accommodate Five nos. Four Pole MCCBs of maximum capacities of 400Amp. each including energy meter F) The provision for solid connection with aluminium strips with heat shrinkable sleeves from Main L.T Bus bar to each compartment of MCCB so as to enable the executing agency at site for connection with MCCB. All as per KPDD Specification
6
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc.
Packaged Substation - 100 kVA: Supply, Erection on existing C.C. foundation, Testing &Commissioning of 11kV Outdoor type Package Sub-Station consisting of 11/0.433kV, 100 kVA Oil type transformer, MV panel, LT panel inside GI sheet steel /Metallised Epoxy enclosure with interconnections, fully type tested as per the IEC-1330 complete in all respect each consisting of following items & as per detailed technical specifications: A) 3way Non - Extensible unit RMU with 2no. 200 A load break switch & 1 no. 200A tee off with SF6 circuit breaker / VCB self powered with O/C + E.F. Relay, M.V Metering arrangement with digital electronic meter, C.T' etc. to complete as required to entire satisfaction of Engineer-in-charge. B) 1 no. 11 kV / 433V, 100 KVA three phase, DYN11, +5% to - 5% in steps of 2.5% at line end of HT side , off lead tap, oil cooled type transformer with Cu winding and standard fittings C) 1 No. 433V, 200A LT devices with PVC sleeved Aluminium busbars. D) One no. 4pole 1000A, 25kA MCCB with microprocessor Based Release. E) Adequate compartment to accommodate Five nos. Four Pole MCCBs of maximum capacities of 400Amp.each. Including energy meter F) The provision for solid connection with aluminium strips with heat shrinkable sleeves from Main L.T Bus bar to each compartment of MCCB so as to enable the executing agency at site for connection with MCCB. All as per KPDD Specification
3
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of MCCB as required for the outgoings of the existing PAC.Sub stations with necessary arrangement as required of specifications 400 Amp.,4 pole,433 V,25kA, as per KPDD Specification
39
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of MCCB as required for the outgoings of the existing PAC.Sub stations with necessary arrangement as required of specifications 200 Amp.,4 pole,433 V,25kA, as per KPDD Specification
3
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 11KV Trivectormeter including all accessories like CT/PT Unit , power cables etc., as per KPDD Specification
21
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of prefab bedding structure for 1 MVA DT, as per KPDD Specification
3
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of prefab bedding structure for 630 KVA DT, as per KPDD Specification
4
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of prefab bedding structure for 400 KVA DT, as per KPDD Specification
5
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of prefab bedding structure for 250 KVA DT, as per KPDD Specification
6
-
-
Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of prefab bedding structure for 100 KVA DT, as per KPDD Specification
3
-
-
Dismantling works:
-
-
-
Dismantling of existing ACSR 100/50 Sqmm HT and transportation back to Divisional Stores. As per Instructions of Electrical Incharge.
24
-
-
Dismantling of existing MS Channel Iron 4/5/6 Feet long and transportation back to Divisional Stores. As per instruction of Electrical Incharge.
1000
-
-
Dismantling of existing 11 kV Pin Insulators complete and transportation back to Divisional Stores. As per instruction of Electrical Incharge.
333
-
-
Dismantling of existing 11 Disk Set and transportation back to Divisional Stores.As per instruction of Electrical Incharge.
4
-
-
Dismantling of existing ST 8/9 Mtr Long Pole and transportation back to Divisional Stores. As per instruction of Electrical Incharge
169
-
-
Dismantling of existing PCC/Wooden Pole and transportation back to Divisional Stores. As per instruction of Electrical Incharge.
35
-
-
Dismantling of existing Substations and transportation back to Divisional Stores. As per instruction of Electrical Incharge.
35
-
-
Civil works:
-
-
-
Excavation in any type of soil including hard laterite soil as per site condition in complete manner as required including backfilling, Compaction in layers as specified as per specifications and as directed by Engineer in charge.
8977
-
-
Supply, Laying, including carriage,loading Unloading etc. of Sand for cushioning of the cables in the trench whenever nesessary as per site condition in complete manner as required and as per the directions of Engineer
1266
-
-
Providing laying and fixing of . of RCC (M-20) protective cover 60 mm thick and minimum 300 mm wide for underground cables, including required reinforcement and necessary shuttering.inclding cost of reinforcement @ 1% per cum and as per the directions of Engineer. or as per the codal procedure.
16695
-
-
Providing ,laying and fixing of Cement Tiles of size 300mm length x250mm width x 37mm thick as a protective cover for underground cables as per site condition in complete manner as required.
126
-
-
Providing laying in position of cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 40 m nominal size for foundations) as required in complete manner and as per the directions of Engineer.
16
-
-
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. and as per the directions of Engineer
100
-
-
Cement plaster. of 15 mm cement plaster in 1:4 (1 - cement: 4 -fine sand) for foundations of RMU, complete in all respect and as per the directions of Engineer.
75
-
-
Construction,laying of masonry chamber :
600x600x900mm.inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse s&) including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover & frame to be not less than 38 kg (weight of cover 23kg & weight of frame 15 kg) & RCC top slab 1:2:4 mix (1 cemenf :2 coarse s& : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine s& : 10 graded stone aggregate 40 mm nominal size) &inside plastering with cement mortar 1:3 (1 cement : 3 coarse s&) 12 mm thick, finished with a floating coat of neat cement complete as per standard design with common burnt clay F.P.S. (non modular ) bricks of class designation 7.5.
7
-
-
Supply, installation testing, carriage, etc. of Wire mesh fencing around the packaged RMU of size upto 8'x4 ' made out of wire mesh 1"x1" squre including fixing in cement 1:2:4 including welding cutting etc. complete in all respects.
7
-
-
Design and Construction of Control Room Building of 10ft x 12ft plinth area including all Civil, Electrical, Sanitary, Plumbing, Air-conditioning and allied works. The building shall have a Stilt Floor and a First Floor above HFL and will be constructed as RCC framed structure as per approved design. The building shall have brickwork in 1st class bricks with 1:6 cement mortar, cement plaster 1:4, cement concrete flooring 1:1.5:3, Aluminium doors & windows (Standard Sizes) adequate in numbers on all the sides of building, Painting on walls /ceilings etc., RCC Stairs, MS ornamental Railings , CGI Roof on Angle Iron Truss of Standard Sizes with RCC Slab complete along with CCTV facility (2 CCTV per CSS) for effective monitoring, with a SCADA operated control unit., one desktop computer system connected to SCADA enabled Compact substations and a 3 kVA inverter. The work includes all Sanitary, Plumbing and Electrical Works including all required fixtures of approved brand and specifications. The Job includes all types of surveys, planning, designing, preparation of drawings, procurement, and construction activities. The designs and drawings shall be got approved from the Employer before execution of works. The cost shall include vetting of structural designs by third party accredited agency approved by the Employer.
1
-
-
Supply, Laying, Testing of GI Pipe 150 mm dia with required no of collars for road crossing including termination points.
2041
-
-
Supply, laying in position, testing,and commissioning icluding labour, carriage, etc. of RCC protective cover of size 300 mm (width) x 300mm (Length) x 60 mm (Thickness) for underground cables .
10215
-
-
Construction laying in position,and commissioning icluding labour, carriage, etc. of Brick Masonary Chamber 900x900x1050mm with RCC top slab, Cast Iron cover in CI Frame (38Kg) after 500 mtrs and as per site requirements including Communication Junction boxes of size 900x600x230 mm, pre fabricated using 2mm thick GI sheets, including fixing on brick masonary wall.
74
-
-
Maintainance and Repairs of all the equipments and installations inluding all civil and mechnical items for a Period of 5 years
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements