Srinagar Smart City Limited Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Srinagar Smart City Limited Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date1 Apr 2023
Closing Date26 Apr 2023
Tender Amount₹ 4,00,00,000
Costs
EMD
₹ 8,00,000Document Cost
₹ 5,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_SSC_209113_1Bid Award Id
ViewTender No
E-N.I.T NO. 01-SSCL OF 04,2023-24. Dt-01-04-2023Tender Authority
Srinagar Smart City Limited ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 meter lead as per direction of Engineer-in-Charge
34
-
-
Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge.
2
-
-
Dismantling steel work manually/by mechanical means in built up sections without dismembering and stacking within 50 meters lead as per direction of Engineer-in-charge:
500
-
-
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, lead upto 50 meter and lift upto 1.5m, as directed by Engineer-in-Charge. All kinds of soil :
135
-
-
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:
1519
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
200
-
-
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:
-
-
-
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
45
-
-
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
169
-
-
Pre-casting & Placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. pipe 40mm dia and 450mm long with 150x150x6 mm M.S. plate welded at bottom and embeded 150 mm in cement concrete 1: 3: 6 (1 cement:3 coarse sand:6 graded stone aggregate 20 mm nominal size) including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing.
25
-
-
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge.
Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.
-
-
-
All works upto plinth level
495
-
-
Providing and placing in position precast reinforced cement concrete waffle units, square or rectangular as per design and shape for floors and roofs in 1:1½:3 (1cement : 1½ coarse sand : 3 graded stone aggregate 10 mm nominal size), including flush or deep ruled pointing at joints in cement mortar 1:2 (1 cement : 2 Fine sand), making necessary holes of required sizes for carrying through service lines etc., providing steel hooks for lifting etc, form work in pre casting, handling, hoisting, centering and erection complete for all floor levels including curing but excluding the cost of reinforcement.
7
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:
Hard drawn steel wire
50299
-
-
Centering and shuttering including strutting, propping etc. and removal of form for:
-
-
-
Foundations, footings, bases of columns etc. for mass concrete.
750
-
-
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
1800
-
-
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :
Cement mortar 1:6 ( 1 cement : 6 coarse sand)
20
-
-
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
20
-
-
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
500
-
-
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes
2500
-
-
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
M.S. tube
22500
-
-
Crazy marble stone flooring, including filling the gaps with light shade pigment with white cement marble powder mixture ( 3 parts of white cement : 1 part of marble powder) by weight in proportion of 4:7 ( 4 cement marble powder mix : 7 white, black or white and black marble chips of sizes from 1mm to 4mm nominal size by volume), with under layer 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size), including rubbing, polishing and cement slurry and curing complete.
18 mm thick crazy marble stone white, black or as specified.
100
-
-
Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) :
100
-
-
40mm thick fine dressed stone flooring over 20mm (average) thick base of cement mortar 1:5 (1 cement: 5 coarse sand) with joints finished flush and curing complete:
Red sand stone
50
-
-
Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
20
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of atching shade complete.
20
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete
Size of tile 600x600 mm
20
-
-
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
375
-
-
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
375
-
-
12mm Cement plaster of mix:
1 : 6 ( 1 cement : 6 fine sand)
300
-
-
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer
50
-
-
Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm
100
-
-
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc complete:
On steel work
200
-
-
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening /binding material to fill up interstices of coarse aggregate, watering and compacting to the required density.
450
-
-
Providing and fixing Glow studs of size 100x20mm made of heavy dutybody shall be moulded ASA (Acrylic styrene Acryloretrite) or HIP (High impact Polystyrene) or ABS having electronically welded micro-prismatic lens with abrasion resistant coating as approved by Engineer-in-charge. The Glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro-reflective surface shall be 35 +/- 5 degrees to base. The reflective panels on both sides with at least 12cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS : 873 part 4 : 1973. The studs shall be fixed to the road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge.
150
-
-
Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of Engineer-in-Charge.
50 to 100 mm average compacted thickness with bitumen of grade VG-30 @5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Drum Type Hot Mix Plant of 60-90 TPH capacity.
23
-
-
Providing and applying 2.5mm thick road marking strips (retro-reflective) of specified shade/colour using hot thermoplastic material by fully/semiautomatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.
225
-
-
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of the joints except at sharp curve shall not to be more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment).
(Precast C.C. kerb stone shall be approved by Engineer-in-charge).
102
-
-
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
450
-
-
Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs,marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note: - One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading providedshall remain to be the property of the contractor on completion of the work).
750
-
-
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
225
-
-
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colou r& pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge.
-
-
-
60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
300
-
-
80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
125
-
-
Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1cement:4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in charge.
375
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.
-
-
-
Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.
-
-
-
20mm nominal outer dia pipes.
50
-
-
32mm nominal outer dia pipes.
30
-
-
External work including trenching, refilling etc.
-
-
-
50mm nominal outer dia pipes.
50
-
-
100mm nominal outer dia pipes.
50
-
-
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
1000
-
-
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.
150 mm diameter
100
-
-
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) including bed concrete as per standard design.
150 mm diameter S.W. pip
100
-
-
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete:
450 mm dia. R.C.C. pipe
1500
-
-
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :
-
-
-
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
50
-
-
Clearing Snow (without frost) from Roads, manually;
Snow depth over 650 mm but upto 750mm
3000
-
-
Providing of 7 way 40 mm Multi Ducts with solid permanently solidly lubricated silicore in inner layer for ICT fibre cables conforming to ASTMF 2160, ASTM D 2444 and / or equivalent Indian Standard. External sheath shall be in orange color and shall be freen from visual defects like blisters, shirnk holes, flaking scratches, groove lines & surface roughness. the color of the 7 nos. PLB HDPE ducts shall be green, blue, yellow, brown, voilet, grey, red for differentiation. outer sheet thickness shall be 1.2 mm, 0.2mm. The inner surface of multi channel ducts shall be spirally ribbed & shall be of a configuration for faster installation of cables. Wall thickness (mm) of each of ducts excluding rib height shall be 2.9 mm 0.3 mm. ISO Requirements - ISO 9001, 14001, 18001, complete as per specifications and directions of Engineer - in - charge.
750
-
-
Providing & fixing of Totem (LED Signage) suitable for outdoor installation, having display size of 4.2' (feet) width x 6.2' (feet) height, complete with outdoor LED modules of 4 mm SMD outdoor brand delta or lower pixel pitch having brightness of minimum 4500 nits. Item include Structure MS and Aluminium IP X3, 12mm tempered glass, built in Media Player, power supplies, reciver cards, LED controller with builtin GSM module. Power consumption less than 2500 W and minimum 2 years warranty. Item to be installed as per vendor's specification & complete as per direction of Engineer-in-Charge.
2
-
-
Supply & Fixing of Double bucket Dustbin, of Capacity (liters) 40, Size (L x W x D mm) 1180 x 1000 x 1000 (mm). Bin will be manufactured in complete laser process to provide accurate and neat borders. Brand: Sintex, Chevron or Equivalent.
30
-
-
Supply & Installation of MS CNC Laser Cut Panel of below mention thickness, Aesthetic fixture made of MS, as per design & drawing given by architect. Item include cost of ms sheet, cutting & installation on site. All work to be completed as per instruction of Site in charge.
6 mm thick ms sheet
29
-
-
8 mm thick ms sheet
39
-
-
Providing and fixing on flooring Wood Plastic Composite Decking (146x21), with alumimium joist 50x25 and clips. (Chocolate color) including Fitting charges of WPC Decking all complete as per vendor specifications.(Rate is not including transportation charges).
20
-
-
Supply and fixing of Bollard made from mid steel with CNC machine finishing with 165mm outer diameter , 140mm inner diameter and 1030mm Height. Expose height 730mm from above Ground level andfixed the remaining 300mm below the GL. Two number of circular rib of R10mm radius are provided at the top and bottom of the bollard. 4 Nos of 15mm width retro reflective sheet pasted at the top and bottom groove by hot blow air sticking process for an ambience look and nighttime visibility. The whole product is power coated as per standard recommendation of Engineer. For fixing the Bollards with M15 cement concrete 45cm x 44cm x 60cm, 55cm below ground level with 140dia x 250mm inner sleeve inserted for 150mm below ground level and 100mm projected above ground level. The inner sleeve is fixed with bollard using M16 bolt of 200mm length.
25
-
-
Providing and laying precast saucer type drain of size 600 x 300 x 50mm with M30 GRADE concrete including the Cutting of the existing bituminous surface of 10 cm thicckness and PCC of 1:3:6 for leveling and maintain the gradient to drain the water from raod to Storm water Drain etc and complete.
750
-
-
HORTICULTURE AND LANDSCAPING
-
-
-
Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing off by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure)
450
-
-
Supplying and stacking of good earth at site including royalty (earth measured in stacks will be reduced by 20% for payment)
338
-
-
Supplying and stacking at site dump manure from approved source including carriage complete (manure measured in stacks will be reduced by 8% for payment)
-
-
-
Screened through sieve of I.S. designation 4.75 mm
113
-
-
Rough dressing of the trenched ground including breaking clods.
68
-
-
Fine dressing of the ground
8
-
-
Mixing earth and sludge or manure in proportion specified or directed by officer in charge.
450
-
-
Spreading of sludge, dump manure or/and good earth in required thickness as per directions of officer in-charge (cost of sludge, dump manure or/and good earth to be paid separately)
450
-
-
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 part of stacked volume of earth after reduction by 20% :1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish & surplus earth, if any with all leads & lifts (cost of sludge, manure or extra good earth, if needed, to be paid for separately)
Holes 90 cm dia& 90 cm deep
10
-
-
Providing and fixing M.S tree guard 50 cm square in plan, height 1.40 meter above ground level and 0.50 meter below ground level. The vertical members shall consist of four nos. angle iron of size 25x25x5 mm, 1.9 m long, one at each corner and 8 nos flat iron of size 25x5 mm, 1.4 m long. The vertical members shall be welded to 4 nos. 25x6 mm M.S flats placed horizontally around the vertical members of the cage. One name plate of 1 mm thick M.S sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD/PWD/any other approved name. The tree guard shall be fixed to the ground by making suitable holes and by embedding four corners leg in the ground, including refilling the earth, compaction etc. complete. The tree guard shall be painted with two or more coats of synthetic enamel paint of approved brand and manufacture over a coat of primer complete in all respect.
10
-
-
ELECTRICAL WORK
-
-
-
Exterior LT Panel : Supply installation, testing & commissioning of IP66 LT panel suitable for 415 V, 3 phase 4 wire 50 Hz AC supply system, RYB LED indicators, VAF digital metering. Cable entry and outgoing are only with suitable sizes of screw less glands, including with all accessories copper bus bar, din rails, earth links, neutral links, glands, locks, connectors, operation complete with all respects. (as per the SLD attached no. LUC/S.S.C/SLD/T2E).
-
-
-
Cubical : Supplying and erecting IP66 Box opaque lid fastener for tool operation sealable box walls without knockouts external brackets for wall fixing included, colour: grey, RAL 7035, material: PC (polycarbonate) mounting plate, glands and complete with all required accessories and hardware to complete the job in all resepcts, Built in dimensions W 600 x H 600 x D 300 (Tolerance ± 10%) material: PC (polycarbonate), impact strength IK 09 (10 Joule), in accordance with IEC 62208:2011
1
-
-
Supplying and erecting bus bar chamber triple pole with neutral with four copper bars, 500V, 100A complete
1
-
-
Supplying, erecting & marking FPMCB 40A to 63A B series
1
-
-
Supplying, erecting & marking TPN MCB 6A to 32A, B series in
4
-
-
Supplying, erecting & marking SPN MCB 6A to 32A, B series (for lighting)
4
-
-
Supplying, installation & marking of surge arrestor / surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 100 kA for
three phase and neutral
1
-
-
Supplying & erecting single phase 2 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery backup, 2 pole contactor upto 60 A, with maintenance mode to switch ON
2
-
-
Termination Junction box : Supply, installation, testing and commissioning of the PC (Polycarbonate) Termination junction box (IP66), terminal with 2 clamping units per pole 5-pole per pole, 4 x 4 mm² r / f, included cable entry: 3 x ESM 40, sealing range Ø 17-30 mm with one cable entries M 32 from the rear side lid fasteners sealable without accessories external brackets for wall fixing included colour: grey, RAL 7035, rated insulation voltage Ui = 690 V a.c./d.c., in accordance with IEC 60670-22, Incoming - 1 no. 4 core 4.0/2.5 sq mm copper armoured cable Outgoing - 2 nos. 3 core 2.5/1.5 sq mm copper armoured cable. Built in dimensions W 210 x H 155 x D 92 (Tolerance ± 10%) material: PC (polycarbonate), impact strength IK 09 (10 Joule), in accordance with IEC 62208:2011
1
-
-
Empty encloser for led driver : Supply installation testing & commisioning of Empty box (IP66) with installation equipment on DIN rails or mounting plates (order separately) with opaque lid fastener for tool operation sealable box walls without knockouts external brackets for wall fixing included, colour: grey, RAL 7035, material: PC (polycarbonate) mounting plate, glands and complete with all required accessories and hardware to complete the job in all resepcts. Built in dimensions W 170 x H 220 x D 96 (Tolerance ± 10%) material: PC (polycarbonate), impact strength IK 09 (10 Joule), in accordance with IEC 62208:2011
4
-
-
Supply installation testing & commisioning of Empty box (IP66) with installation equipment on DIN rails or mounting plates (order separately) with opaque lid fastener for tool operation sealable box walls without knockouts external brackets for wall fixing included, colour: grey, RAL 7035, material: PC (polycarbonate) mounting plate, glands and complete with all required accessories and hardware to complete the job in all resepcts. built in dimensions W 215 x H 320 x D 106 (Tolerance ± 10%) material: PC (polycarbonate), impact strength IK 09 (10 Joule), in accordance with IEC 62208:2011
3
-
-
Cable : Supplying, erecting & terminating XLPE armoured cable 1100 V. 4 core 16 sq. mm. copper conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe
50
-
-
Supplying, erecting & terminating XLPE armoured cable 1100 V. 4 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe
230
-
-
Supplying, erecting & terminating XLPE armoured cable 1100 V. 3 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe
360
-
-
Supplying, erecting & terminating XLPE armoured cable 1100 V. 2 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe
135
-
-
GI Conduit : Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. Erected for enclosing XLPE armoured cable on wall/pole
130
-
-
Earthing System : Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete.
2
-
-
Exterior Luminaires : Supply installation testing & commissioning of exterior rated posttop of system lumen output should not be less than 2000 lumen (Tolerance ±15%), the power consumption should not be more than 50 watts, 360° symmetrical optics, CCT 3000K. Single piece with circular shaped plant made of die cast aluminum using pressure die-casting process,with a decorative Top luminaire which is also made of die cast aluminum using pressure die-casting process, fixed on the top.Auxiliary and optical compartment can be accessed by tilting the top frame. Bottom frame in single piece, made of die cast aluminum using pressure die-casting process with a three curved uprights decorated which is also made of die cast aluminum using pressure die-casting process, fixed at the bottom with a hole (28 mm) for fixing to support. Frosted Screen made of polymethylmethacrylate (PMMA) moulded in a single piece using Injection moulding process. Screen's Impact resistance: IK06. Pure polyester powder coating in the same color as of the pole/as per the lighting consultant. Optical Compartment IP Rating - IP 66. Height – 800mm, Dia. - 400mm, Colour Rendering Index: Ra 70. Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection upto 4kv(an additional surge protection device of 10kV also provided in-built the fixture). Modular (2 X 2) refractive lens in PMMA with Type-II/III/IV photometric distribution options. protection screen in extra-clear tempered glass with impact resistance IK 08.LM80 (All the technical parameters of luminaire need approval from lighting designer)
30
-
-
Supply installation testing & commissioning of exterior rated flood light IP66, (as per application). System lumen output should not be less than 500 lumen with snoot (Tolerance ±15%), The power consumption should not be more than 10 watts, 30° beam angle with tolerance of ±15%, CCT 2700K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be anthracite gray where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI80, SDCM≤4. The driver should be included non dimmable with PF0.9 & THD20%. Leader cables, jumper cables, IP66 connectors are inclusive. Minimum IK06. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware for successful operation of the luminaire. (All the technical parameters of luminaire need approval from lighting designer)
120
-
-
Supply and erection of 5000mm high decorative pole made out MS Pipe Ø76.1mm confirming to YSt 210 and facilitating the luminaire mounting at the top. The pole shall be surface mounted on a concrete foundation. The base plate of the of the pole shall be E 250 grade MS 200 mm x 200mm, 12mm thick confirming to IS2062:2011 shall be facilitated with elongated slots to suit the 300mm, J-type, M16 bolts, Grade 4.6 that shall be provided with suitable nuts and plain washers. The structurally sound pole emerging out of the base plate shall be architecturally designed with a decorative cast aluminium causeway base cover minimum Ø330mm x 500mm (H), above which the leaf decoration cast aluminium structure Ø 150mm is aesthetically positioned. Mounted flower pot. The grade of pressure diecast material shall be ADC12. A GDC embellishment is provided at appropriate height enhancing the decorative outlook of the pole. The grade of gravity die cast material shall be LM6. The Pole welding shall be done with certified welders using a V groove technique with a high end MIG welding process. A base compartment with a die cast aluminium door contoured to the poles's shape housing the gear tray, prewired with 2 way connector. The surface preparation of the pole & components shall be done by shot blasting which is environmentally safe eliminating the chemical and acid use and ensuring the thoroughremoval of impuritise like, rust, oxides and other unwanted particles from the suface for high standard coating. The surface finish of the pole shall be Zinch rich primer coat & pure polyester powder coating or epoxy zinc phosphate primer followed by the environmentally stable Polyurethane based paint. Pole must be connected to earthing. (All the technical parameters of luminaire need approval from lighting designer)
30
-
-
Evaluation Notes How It Works ?