Small Scale Industries Development Corporation Limited Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Small Scale Industries Development Corporation Limited - SICOP Tender
Civil And Construction
Building Construction
Agriculture or Forestry Works
Eprocure
Opening Date11 Oct 2024
Closing Date28 Oct 2024
Tender AmountRefer Documents
Costs
EMD
₹ 26,740Document Cost
₹ 600Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SICOP_259408_1Bid Award Id
ViewTender No
SICOP/GM(P)/2024/01A dated 11-10-2024Tender Authority
Small Scale Industries Development Corporation Limited ViewPurchaser Address
-Website
http://https://www.jksicop.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
b. Roof Panel: Providing & factory made 50 mm thk pre-painted "Standing seam insulated metal panels (sandwich panels) for roofing, with a nominal 1016mm effective cover width with two major trapezoidal corrugations, 50mm high. The insulation core shall be rigid shall be lightly profiled with 56mm wide and 2mm high continuous ribs. The liner portion (internal facer) of the panels shall be lightly profiled 31mm wide and 1.5mm high ribs. Panel external and internal facers shall be manufactured from 0.50mm (TCT) thick pre-painted galvalume steel material and minimum 300 MPa yield strength coated with hot dip metallic Aluminium /Zinc alloy coating, galvalume AZ150 as 150 gms/" total on both sides of Aluminium (55%) & Zinc (43.50 %) & Silicon (1.50%), conforms to IS 15965 or ASTM792M or AS1397 having a paint finish as Silicone modified polyester (SMP) with a total coating thickness of nominal 25 microns. The insulation core shall be rigid, PUR insulation of minimum density 40 Kgs/cum. The panel should be fire resistant and should have excellent fire extinguishing characteristics when tested in accordance with BS EN 13501-1-2007+A1: 2009 with reaction to fire classification satisfying B-s1-d0. Cover width of the panel shall be minimum 1000mm. All fixing accessories, flashings & trims shall be included.
-
-
-
c) Gable End. Gable End will be covered with same panels as of wall upto bottom chord of truss. The triangular truss portion will be covered with 0.50mm wider than the width of the opening including necessary priming and painting etc. d.Roof Projection. The roof will have minimum projection 450mm all around including verandah portion. Purlins will also be extended in the roof at the eaves and at gable roof extension (outside the structure)
-
-
-
e.Wall Panel: Providing and fixing of factory made 50 mm Thick Insulated QuadCore Architectural Wall panel systems with secret fix joinery system made up of two pre coated galvelume steel, fastened on to structural steel work. Structural steel work shall be designed to meet panel fixing requirements. The panels shall have fire safe insulation QuadCore with no fire spread properties, CFC & HCFC free. The Insulation core shall have K -value of 0.018 W/ mk & panel shall gms/m2) (Galvalume® or Zincalume®), Aluminium 55% & Zinc 45%, total on both sides and will have coloruishing characteristics when tested in accordance with BS EN 13501-1:2007+A1: 2009 with reaction to fire classification satisfying B-s1-d0. Cover width of the panel shall be minimum 1000mm. External and internal skin of Architectural Wall panel shall be 0.50 mm Test Certificate conforming to or ASTM A755 or IS 15965:2012 from principle steel supplier with minimum yield stress of 300 N/mm2 coated with Aluminium - Zinc Alloy Coating AZ150 (150 gms/m2) (Galvalume or Zincalume), Aluminium 55% & Zinc 45%, total on both sides and will have colour coating with Silicone Modified polyester (SMP) of Min 35 um total on both sides as per AS/NZS 2728 Class. Quoted Architectural Wall Panel system rate should include cost of all required flashings like drip trim, cap trim, sill trim, header trim, parapet cover, soffit trim made of same materials as of external skin along with 1.2mm thick cold roll formed top hat and angle section, carbon steel fasteners, anchor fasteners, rawl plug fasteners etc complete to meet Architectural & Structural requirements. All flashings & trims shall be sized & designed to integrate with glazing systems. Bidder to provide proof of being OEM or authorisation from OEM alone with catalogue for the puff panel.
-
-
-
f.False Ceiling, 12 mm thick Fully Berkurat sqm Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15% perforated area with perforation size and partitions approved by the Engineer in charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60. g. Windows. Providing and fixing factory made Aluminium powder coated ivory colour sliding glazed window 1.2m in height dimension and 1.00 m in width comprising of multi-chambered frame with in-built roller track and extruded profiles, appropriate dimension of Alluminium extruded glazing beads and extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg). G.I fasteners 100 x 8 mm
-
-
-
size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and joined at all comers, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single/double glass panes, wire mesh and silicon sealant shall be paid separately)Three track three panels sliding window with fly proof S.S wire mesh (Two nos, glazed & one no. wire mesh panels) made of (big series) frame116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 1.75 sqm)
-
-
-
h.Doors :Providing and Fixing factory made Alluminium door frame, made of extruded sections corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with profile of S having wall thickness 2 mm (±0.2 mm), including providing & fixing 3 Nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fasteners, all complete as per manufacturer's specification and direction of Engineer-in-charge Main shutter will be provided with flush both sides of appropriate thickness and Fly proof shutter provided on outside of the door using stainless steel mesh of average.50mm aperture. The main door shall be provided with built in locking system of make Godrej Harrison etc. Two Nos Alluminium tower bolts of 200mm size from inside and one sliding bolt 300mm long and one bowl handle 150mm size to be provided on both in and out side of each shutter. Fly proof shutters will be provided with hydraulic door closers. Internal doors with not be provided with fly proof shutters. All designs, drawings including design of foundation, truss fabricated structure, plinth beam etc. have to be prepared by the contractor on their own expense and same shall be vetted by the contractor from DIQC /IIT/NIT. The rates are inclusive of all taxes, carriage, loading and unloading complete job.
433
-
-
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete Job
28
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable size G.I box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Wire Make: Anchor/Havells/Vguard/Polycab/ Finolex . Conduit Make: AKG/Anchor/Finolex/Polypack
17
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Wire Make: Anchor/Havells/Vguard/Polycab/ Finolex . Conduit Make: AKG/Anchor/Finolex/Polypack
-
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
32
-
-
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
35
-
-
Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) havells/ kei/rr cable/polyab.
25 sq.mm 2 core
23
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(Make: Havells/ABB/Legrand/Anchor/vguard/L&T/Schneider)
-
-
-
5/6 amps switch
5
-
-
3 pin 5/6 A socket
5
-
-
15/16 A switch
5
-
-
6 pin 15/16 A socket
5
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(Make: Havells/ABB/Legrand/Anchor/L&T/Schneider) 8 Module
3
-
-
20/22 watt LED 4 feet tube light fitting/fixture Aluminium housing with 2000 Lumens and min lumens efficiency 100 lumens/watt P.F .90. (Make:- Philips/Bajaj/Anchor/Panasonic/Havells).
2
-
-
Supply and fixing pvc batten / angle holder including connections etc as required.(ISI)
2
-
-
Supply and fixing of 9 watt LED bulb. (Make Panasonic/wipro/Philips).
2
-
-
Supplying and installation of recessed/surface mounted slim square type down lighter of following rating.
18 watt/ 20 Watt
(Make: wipro/ crompton/ Panasonic/ phillips/ Jaquar)
10
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
(Make: VGuard/ Havells/ABB/anchor)
-
-
-
Single Pole
12
-
-
Double pole
6
-
-
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make: VGuard/ Havells/ABB/Anchor/L&T/Schneider)
63 A
2
-
-
Supply, installation,testing and commissioning of ceiling fan 1200 mm sweep along with fan rod upto 2ft. long suitable for operating 240/230v ac,50 hz including connection,etc complete as required.(Make: Bajaj/Havells/Pansonic/Crompton)
4
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(Make: Bajaj/Havells/Pansonic/Crompton)
4
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way (4 + 12), Double door
(Make:- Anchor/Vguard/Havells/ABB/L&T)
1
-
-
Supplying, installation, testing and commissioning of 1.5 Ton Inverter type Split AC's (copper) (3 star) Hot/ Cold (all weather) type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. Repairs made to wall whereever required. Warrantee.:- a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation.
(Make: Voltas,Bluestar,Carrier).
1
-
-
Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. 5 KVA Warrantee.:- 2 Years from the date of installation. (Make:Vguard,Microtek, Philips, Luminous)
1
-
-
Evaluation Notes How It Works ?
Potential Partner