Small Scale Industries Development Corporation Limited Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Small Scale Industries Development Corporation Limited - SIDCO Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Oct 2024
Closing Soon14 Nov 2024
Tender Amount₹ 2,67,00,000
Costs
EMD
₹ 5,34,000Document Cost
₹ 18,000Tender Fee
Refer Documents
Summary
Balance Work Of Electric Component With Allied Works Of Nift Buildings (pkg 3rd) At Nift Ompora Budgam
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SIDCO_262186_3Tender No
Constt/Div/NIFT/024/10Tender Authority
Small Scale Industries Development Corporation Limited ViewPurchaser Address
-Website
http://https://www.jksicop.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supplying and fixing single pole blanking plate in the existing modular plates complete etc. as required (MAKE Panasonic LEGRAND,L&T HAGER,INDO ASIAN & HPL).
200
-
-
Supplying and fixing following way, surface/recess mounting, vertical type 415 volts, TPN MCB Distribution board of sheet steel , dust protected duely power poainted inclusive of 200Amp tinned copper busbar, common neutral link, earth bar, dinbar for mounting MCB's (but withoit MCB'S and incomer) as required (note vertical type MCB TPDB is normally used where three phase outlets are required).(Make legrand, L&T, hager, IndoAsia and HPL)
A) 8 WAY(4+24 way), double door
10
-
-
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.(make Legrand, L&T, Hager, IndoAsian & HPL).
63 Amp
60
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. (MAKE LEGRAND,L&T HAGER,INDO ASIAN & HPL)
63 Amp
20
-
-
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.
(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm
1000
-
-
Providing and making earthpits including the cost of 300 mm x 300 mm all earth work, masonry enclosure with CI FRLSame & cover plate having locking arrangement complete as per IS 3043:1987 for body earth
68
-
-
Supply and laying 50mm x 6mm GI strip at 0.50 meter below ground as strip earth electrode including connection/ terminating with GI nut, bolt, spring, washer etc., as required (jointing shall be done by overpalling and ith 2 sets of GI nut bolt & spring washer spaced at 50mm)
800
-
-
Supply Installation testing & commitioning of Maintenance free hot deep galvienised on 250 microns GI Earthing system with 10 ft long , 80 mm dia & 3.0mm wall thickness. (Pipe-In-Pipe with Flat Terminal ) Tecnology.with 2 Bag of Electron High Conductive & Anti Corrosive Compound Spec : 3 mtr Length x 80 mm dia/ 2.96 mm thick / 250 micron Electrode Thickness : 3.0 mm / ISI Class - B, Hot Dip Galvanised 250 Microns Terminal size should be 40 x 10 mm thick (For use : All Body Earthing) with - CPRI ,ROHS,& Soil Resistivity test certificate. (LT panel HT panel HT meter, two pole and buildings sub panel
68
-
-
SH-V (PANELS)
LT PANEL (TTA Design as per IEC 61439 - 1/2) Make: (Lengard XL-3/ Schneider - Blokset/ ABB - MNS OEM)
Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of required value symmetrical at 415 volts, fabricated from 2 mm thick CRCA MS sheets for load bearing and 1.6mm for non load bearing with multi fold design, hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below. The panels shall be internal Arc tested.
INCOMING:
2 Nos. 2000A, 415V, Icu = 45kA, 4P EDO ACB with Microprocessor based release ( MPR-1H or equivalent) having , Over current 40%-100% - Time setting,Selective short circuit 60%-1000% - Time setting ,instanteneous short circuit 150%-1500% , Under voltage time setiing 60%-95% Over voltage time setting 105 % -120% residula Voltage 10%-20% time setting EARTH earth fault with adjustable setting 20%-100% , Master Trip Relay Over Voltage & Under Voltage, Reverse power relay, Single phase preventer protection. REF protection 25 KVAR Capacitor with 63A MCCB 50 KA. ( transformer)
3 Nos. 1250A, 415V, Icu = 45kA, 4P EDO ACB with Microprocessor based release having , Over current 40%-100% - Time setting,Selective short circuit 60%-1000% - Time setting ,instanteneous short circuit 150%-1500% ,EARTH earth fault with adjustable setting 20%-100% , Master Trip Relay Over Voltage & Under Voltage, Reverse power relay, Single phase preventer ,( Release to be coordinated with the DG controller Those feature are available in the controller can be deleted from incomer)
1 Nos. 400A, 415V, Icu = 50kA, 4P MOTORISED MCCB with Microprocessor based release having , Over current 40%-100% - Time setting,Selective short circuit 60%-1000% - Time setting ,instanteneous short circuit 150%-1500% ,EARTH earth fault with adjustable setting 20%-100% , Master Trip Relay Over Voltage & Under Voltage, Reverse power relay, Single phase preventer ,( Release to be coordinated with the DG controller Those feature are available in the controller can be deleted from incomer) Nos. 0-500V Digital type Voltmeter with selector switch.
2 Nos. 0-400A Digital type Ammeter with selector switch with CT's 400/5A
3 Nos. 0-1250A Digital type Ammeter with selector switch with CT's 1250/5A
1 Nos. 0-2000A Digital type Ammeter with selector switch with CT's 2000/5A
6 no. PS class CT's 2000/5A for the protection
12 no. PS class CT's 1250/5A for the protection
3 no. PS class CT's 400/5A for the protection
6 Nos. Digital type Multifunction Meters to show KWH, KVAH, P.F. and Frequency
6 Set of phase indicating lamps with MCB protection.
6 Set of indicating lamp to indicate OPEN, CLOSE, TRIP.SPRING CHARGE. RYB PHSE INDICATING LAMPS
Busbars: 3000A TPN busbars of aluminium alloy.
630A TPN busbars of aluminium alloy.
MINI PLC for Auto load management and coordination for the Auto synchronizing though DG controllers 3no. 750 KVA, 1 NO. 250 kva with on off the breaker for 2 no. transformer and 3no, of the Bus copular according to the logic ( synchronizing shall be done by the DG controller) panel builder should coordinate with the DG vendor forinputs in the Mini PLC
PLC SYSTEM: PLC system synchronisation and AMF logic for 5 DG sets and control of two no. Grid supply feeder complete with following accessories for auto load sharing /management / synchronising for D.G. Sets and control and interlocking as per scheme in SLD including control wiring for the system.
Engine cranking relay , Indicating lamps, Push buttons with elements, Auto / manual selecter switch Battery charger, DC Ammeter, DC voltmeter, 8 point alarm annuniciator, Hooter
1
-
-
Auxiliary contractors, Control MCBS , Double voltmeter (134 mm Sq) analog , Double frequency (134 mm Sq) analog , Synchroscope (134 mm Sq), 60W, 240V AC GLS Bulb, 5A, Brass baten holder, Synchronising ON/OFF switch , Set selector switch , PLC/Manual selector switch , Push buttons with elements, Auxillary relays, Motorised potentio meter, Phase angle transducer , Voltage raise/lower joystick , Speed raise/lower joystic , Check synchronising relay 5 DG programmable logic controller (power monitor 33100 based) window based grafix software+others accessories and controls. Power Supply UPS - 2KVA with maintenance free batteries, charger etc. for 10 minutes backup. - 1 No
Computer pentium-4 80GB hard disc., colour monitor + colour printer - 1 Set
Any other relay/control/meter /System whether meintioned or not but required for successful/efficient operation of the system shall also be included.
1 no. Ventillating fan in PLC Panel Compartment
Outgoing:
2Nos. 1250A, 415V, Icu = 50kA, TPN MDO ACB with electronic trip unit for over current selective short circuit, instanteneous short circuit and earth fault protection and a set of CT's, ammeter with ammeter selector switch ON/OFF Indicating Lamps with MCB.
5Nos. 630A, 415V, Icu = 50kA, TPN MCCB with electronic trip unit for over current selective short circuit, instanteneous short circuit and earth fault protection and a set of CT's, ammeter with ammeter selector switch ON/OFF Indicating Lamps with MCB.
7Nos. 400A, 415V, Icu = 50kA, TPN MCCB with electronic trip unit for over current selective short circuit, instanteneous short circuit and earth fault protection and a set of CT's, ammeter with ammeter selector switch ON/OFF Indicating Lamps with MCB.
2Nos. 200A, 415V, Icu = 50kA, TPN MCCB with electronic trip unit for over current selective short circuit, instanteneous short circuit and earth fault protection and a set of CT's, ammeter with ammeter selector switch ON/OFF Indicating Lamps with MCB.
2Nos. 160A, 415V, Icu = 50kA, TPN MCCB with electronic trip unit for over current selective short circuit, instanteneous short circuit and earth fault protection and a set of CT's, ammeter with ammeter selector switch ON/OFF Indicating Lamps with MCB.
5Nos. 100A, 415V, Icu = 50kA, TPN MCCB with electronic trip unit for over current selective short circuit, instanteneous short circuit and earth fault protection and a set of CT's, ammeter with ammeter selector switch ON/OFF Indicating Lamps with MCB.
1Nos. 800A, 415V, Icu = 50kA, TPN MCCB with electronic trip unit for over current selective short circuit, instanteneous short circuit and earth fault protection and a set of CT's, ammeter with ammeter selector switch ON/OFF Indicating Lamps with MCB.with one no. change over switch ( For Fire Pump)
2Nos. 125A, 415V, Icu = 50kA, TPN MCCB with electronic trip unit for over current selective short circuit, instanteneous short circuit and earth fault protection and a set of CT's, ammeter with ammeter selector switch ON/OFF Indicating Lamps with MCB.
2Nos. 200A, 415V, Icu = 50kA, TPN MCCB with electronic trip unit for over current selective short circuit, instanteneous short circuit and earth fault protection and a set of CT's, ammeter with ammeter selector switch ON/OFF Indicating Lamps with MCB.
Bus Copulars
1Nos. 1250A, 415V, Icu =50kA, TPN EDO ACB with ON/OFF/TRIP Indicating Lamps with MCB.
2Nos. 2000A, 415V, Icu = 50kA TPN EDO ACB with ON/OFF/TRIP Indicating Lamps with MCB.
1Nos. 400A, 415V, Icu = 50kA 4P Motor duity contactor with ON/OFF/TRIP Indicating Lamps with MCB.
Make of ACB - Legrand -DMX3/ Schneider-NW/ABB -Emax
Make of MCCB - Legrand -DPX3/ Schneider-NSX//ABB -Tmax
All internal wiring of LT panel and capaciter panel connecting with LT panel as per requirement of load and ratings of the panel. (Complete panel described as above)
1
-
-
400 KVA CAPACITOR PANEL400 KVAR CAPACITOR PANEL (TTA Design as per IEC 61439-1/2) Make -(Legrand-XL3/ Schneider-Blokset/ ABB-MNS OEM)
INCOMER :
1Nos. 1000A, 415V, Icu = 50kA, TPN MDO ACB with electronic trip unit for over current selective short circuit, instanteneous short circuit and earth fault protection and a set of CT's, ammeter with ammeter selector switch ON/OFF Indicating Lamps with MCB.
1 Set of phase indicating lamp with MCB
BUS BARS 1250 A TPN bus bars of aluminium alloy.
OUT GOING: 1 Nos. 100 KVAR, capacitor bank with 250A TP MCCB and Contactor, one set of indicating lights and Push Buttons.
4 nos. 50 KVAR capacitor bank with 160A TP MCCB and Contactor, one set of indicating Lights and Push Buttons.
4 nos. 25 KVAR capacitor bank with 100A TP MCCB and Contactor, one set of indicating Lights and Push Buttons.
Additional space to be provided in each Capcitor bank copartment for fixing the filters in future.
1 no. 12 step Electronic type Auto matic power factor correction relay.
Make of ACB - Legrand -DMX3/ Schneider-NW/ABB -Emax
Make of MCCB - Legrand -DPX3/ Schneider-NSX//ABB -Tmax
(Complete panel described as above)
2
-
-
SITC (Suplly , Instalation, Testing & commisioning ) of 1200mm 28 W Energy Efficeint sweep with electronic regulator ANCHOR , Atomberg ,Crompton greavesor equivalent . As per the selection done by Architect.
300
-
-
SITC (Suplly , Instalation, Testing & commisioning ) of Exhaust Fan, suitable for 1-phase, 230V with 2.5 mm square insulated copper conductor wires for connections complete as required. Make :ANCHOR , Panasonic,Crompton Greaves or equivalent . As per the selection done by Architect including bake lite sheet and all other accessories
230
-
-
Supplying, laying, testing and commissioning of 1100 volt grade XLPE insulated, PVC sheathed, aluminium conductor, armoured cable laid on existing cable trays / walls including the cost of saddling and clamping and including the cost of dressing to ensure minimum 1 cable diameter spacing between adjacent cables etc. complete as per specifications, as required and as below in existing cable trench.
-
-
-
3.5 core 300 sq mm XLPE aluminium conductor armoured cable
750
-
-
3.5 core 240 sq mm XLPE aluminium conductor armoured cable
740
-
-
3.5 core 150 sq mm XLPE aluminium conductor armoured cable
185
-
-
3.5 core 70 sq mm XLPE aluminium conductor armoured cable
100
-
-
3.5 core 50 sq mm XLPE aluminium conductor armoured cable
10
-
-
3.5 core 35 sq mm XLPE aluminium conductor armoured cable
300
-
-
Supply, installation ,testing and commissioning of Flood lights with high brightness white leds producing warm white light, non dimable protected with a tempered glass ,power consumption of 50 watt suitable for outdoor use IP 65 rated with all accessories and wiring, controlled gear as required.AFL 0206 Panasonic, philips or equivalent as per the selection of the architect
15
-
-
Supply, Installation & Testing of Prepayment Meters as per “IS 15884: 2010” by “BUREAU OF INDIAN STANDARDS” for AC Direct Connected Static Prepayment Meters. Three Phase Liberty Prepayment Meter 10A-63A with Dual register facility with Home display/ Freedom Unit. Meter should have inbuilt disconnect switches as per BIS requirement with Overload and Low balance alarm facility including all connection wire complete job.
32
-
-
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.
300
-
-
Supply, Installation, testing & Commissioning PC for Local server having i7 processor with 3 GB RAM, 500 GB Hard Disk, Oracle Client, DVD Drive, USB Ports of Standard make. UPS of 500 VA with 15 min. back up, Laser jet Printer.
1
-
-
Vending software is certified by (ISO/IEC 27001) Supply, Installation, testing , Commissioning & Training of the vending System for Tariff designing as per BIS guidelines & Customer Data Base definition
4
-
-
Token Printer with Serial Port ( Epson make).Tokens are meter specified and encrypted with triple des technology. Also the vending system is ISO/IEC 27001 compliance with certification.
90
-
-
Supply, Installation & Testing of Prepayment Meters as per “IS 15884: 2010” by “BUREAU OF INDIAN STANDARDS” for AC Direct Connected Static Prepayment Meters. Single Phase Liberty Prepayment Meter 10A-63A with Dual register facility with Home display/ Freedom Unit. Meter should have inbuilt disconnect switches as per BIS requirement with Overload and Low balance alarm facility including connection wiring complete job.
57
-
-
Supply, Installation & Testing of prepayement meters as per "IS 15884:2010" by "BUREAU OF INDIAN STANDARDS" for Direct connected static pre payement Meters. Three phase liberty prepayement meter 10A-63A with dual register facility with home display/freedom unit. Mter should have inbuilt disconnect switches a per requirement with overloa and low balamce alarm facility.
6
-
-
Supply and laying of 2x2.5 sq mm FRLS PVC insulated Cum Armoured cable
300
-
-
HT PANEL
ONE No. 11 KV HT Panel :
Supplying, installation, testing & commissioning of H.V. air insulated distribution switchgear consisting of 1panel H.T. Board suitable for indoor installation for use on 11 KV 50 Hz earthed system having a symmetrical breaking capacity of 350 MVA at 11 KV comprising of 630A 33 KV vacuum circuit breaker. The panel shall be equipped with following accessories and specification compete as required. HT PANEL INCOMING / OUTGOING 1 No. each as following
One No. 630 A Air insulated Metal clad housing
A set of three 3 phase, 630A PVC insulated copper busbars.
One Tripple pole draw out truck mounted 630 A, 1500 MVA, Isolator fitted with all necessary control devices.
One Trip free, motor charged, spring released closing mechanism fitted with shunt trip suitable for 240 volt AC operation complete with necessary. Auxiliary switches, emergency hand trip device and mechanical ON and OFF indicators.
110/5A ratio, 15 VA, Class 1.0 Resin cast Current Transformers for metering purposes.
Single phase horizontal draw out type resin cast line type potential Transformer of 33 kV/110 volts with 15 VA burden complete connected star / star with fuses as per requirements INSTRUMENT PANEL:
* One 96 mm square, scaled 0-33kV flush type Voltmeter with 3 way and OFF selector switch.
* One 96 mm square, scaled 0-100 amps, flush type ammeter with 3 way and OFF selector switch.
* One static Triple pole very inverse definite mean time over current and earth fault relay with two outer elements connected for over current protection and the middle element for protection with adjustable over current and earth fault setting.
* Trip circuit supervision relay, trip annunciation relay & trip circuit healthy relay.
* One set of Lock out relay.
* One set of Red / Green / Indicating lamps for close and open indication. * One set of Amber indicating lamp for Trip circuit healthy indication.
* One set of white phase indicating lamps for phases.One number of dc Battery charger with batteries and stand as required. (Complete 1no. HT Panel as described above)
1
-
-
Supply, deliver, erection, testing and commissioning of 1250KVA, 11000 / 433 volts delta / star, outdoor oil type naturally cooled Transformer with vector group Dyn II, and on load tap changer of + 5% to - 15% on HT side in steps of 1.25% complete with first filling of oil with accessories as required of 433 volts on LT side the transformers to be provided with cable box on HT side to receive HT cable and LT side to receive LT cables complete as per IS 1180 specification and drawing as required. (Including M20 conrete base of required size comlplete job)
1
-
-
Supplying, laying, testing and commissioning of control cable 6 core 1.5 sq.mm. PVC insulated copper conductor 1.1 KV grade, armoured control cable in trench as required complete in all respect.
10
-
-
Supplying and fixing 1000 mm x 900 mm wide checkered rubber matting conforming to complete as required. 1100 V grade size 1000 x 900 x 15 mm thick
20
-
-
Supplying & fixing standard shock treatment charts in English & Hindi duly framed and covered with glass at different locations.
1
-
-
Supplying of fire bucket painted red and approved quality conforming to IS: 254/1974
4
-
-
Supplying and fixing carbon dioxide fire extinguisher type 4.5 kgs capacity of approved make with wall mounting bracket as required conforming to IS: 2878/1976
1
-
-
Providing & fixing HT danger Notice plate 200 mm x 150 mm made of mild steel at least 2mm thick & enameled white on both sides and with inscription in signal red colour with skull & bone on front side as required.
2
-
-
Providing 11 KV tested hand gloves.
2
-
-
Providing first aid safety box as per requirement.
1
-
-
Supplying , laying, testing & commissioning of following sizes of 11 KV grade Al. Conductor XLPE earthed cable in trench including digging & refilling of the trench etc. as required confirming to IS : 7098. 3 core 300 sq. mm
200
-
-
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of XLPE aluminium conductor cable of 11 KV grade as required..
3 core 300 sq. mm
3
-
-
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs cable of 11 KV grade as required.
3 core 300 sq. mm
1
-
-
DG SET
he DG sets and system offered shall comply to "Environmental Regulations on Engines for Generator Set Application and Generator Sets" issued by Central Pollution Control Board as amended up to date and other statutory regulation as applicable.
Supply, installation, testing and commissioning of Following kVA,415 volts, 3 phase, 4 wire, 50 Hz at 0.8 power factor, ± 1% regulation, prime continuous rating Radiator cooled colded type diesel generating set with canopy along with base frame, brushless Alternator , class H alternator insulation, Static Excitation System, Lube Oil System, Electronic Governor Batteries,Instrumentation, oil fuel tanks, Silencer , Engine Control Panel, AVM pads, AVR Panel.Terminal arrangements shall be suitable for terminating cable with all other associated equipment as required.
Obtaining clearance from Central Pollution Control Board (CPCB) & State Pollution Central Authority in respect of noise level and emission level being within permissible level and obtaining clearance from Electrical Inspectorate. (Including M20 conrete base of required size comlplete job)
-
-
-
250 KVA
1
-
-
750 KVA
1
-
-
Providing, fixing & installing exhaust pipe fabricated out of Class- C NS plate and all fixing accessories and hardwires. The exhaust pipes shall be insulated with 75 mm thick mineral wool insulation wrapped in chicken mesh and clad with 24 gauge aluminium sheet as required for installation at site complete in all respect with miscellaneous structural support for horizontal/vertical exhaust piping including fabrication, hardwares and painting as per specifications:.
-
-
-
300 mm dia
200
-
-
150 mm dia
15
-
-
silencers (250KVA).
1
-
-
silencers (750KVA).
4
-
-
Supplying, installation, testing and commisioning of passive infrared(PIR) technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto 10 amp,for mounting height upto 2.8 meter and for 5 meter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. Make : Legrand , Philips , HPL . As per the selection done by architect (including wiring as required.)
45
-
-
(SUPPLY & INSTALLATION OF UPS) Supply,unloading,shifting installation, testing & commissiong of micro processor /DSP controlled 1 Numbers 6 KVA UPS IGBT based rectifier to achieve THDI 2% for linear load and 3% for non linear load.and input power factor of greater than 0.95 at 50% loading. True Online Double Conversion (VFI as per IEC 62040-3) UPS using PWM IGBT technology , 1 Phase input and 1 phase 220 V output UPS system; and each comprising of the following:
125% rated Rectifier cum charger unit +100% rated Invertor, Integrated in UPS module
100% rated External or inbuilt Galvanic isolation transformers of K-12 Delta/Zigzag type for isolation of input neutral with output neutral ,to be installed after UPS as shown in drawing enclosed. The External Galvanic isolationTransformer to be of same impedance for parallel operation. 100% rated Inbuilt static switch at the invertor output + 2 Nos. 100% rated Inbuilt static switches at the static bypass line.
100% rated Inbuilt Maintenance Bypass.
100% rated moulded case battery circuit breaker having Ithermal, Imagnetic and Automatic U/V trip mechanics.
Web-enabled Monitoring and Management through SNMP protocols for multi-OS environments.
UPS Efficiency to be mininum 93%, at full load
Supplying, unloading,shifting , installing in position, testing and commissioning of Lead Acid sealed maintenance free batteries for 10 KVA UPS system , for providing 10 minutes backup to 10 KVA UPS for full load. The bank of batteries shall comprise required Nos complete as required.
Supply,unloading,shifting , installation, testing & commissioning of matching cabinet/open racks including covering with netlon mesh to house SMF batteries for 10 KVA UPS system along with interconnecting links, MCCB etc. complete as required & as per specifications.
Supply, laying, testing & commissioning of flexible single core copper cable for interconnections between UPS to UPS, UPS to batteries, Isolation transformer to UPS complete as required for 6 KVA UPS,including providing Battery circuit breakers as required.
1
-
-
Providing and fixing in position storage type hot water electrical gyser vertical or horizontal 2.5 kw 5 star including making connections in all respect.Hindware,Atlantic/RO Smithmake 25 litres capacity.
186
-
-
COMMERCIAL Panel (TTA Design as per IEC 61439-1/2) Make -(Legrand-XL3/ Schneider-Blokset/ ABB-MNS OEM)
INCOMER : 1 Nos. 125A, 415V, Ics= 25 KA, 4P MCCB with overload, short circuit protection.
1 Nos. 0 - 500V voltmeter with selector switch, 0-250A ammeter with selector switch, and set of cast resin C.T.'s 125/5A 1 set of Phase indicating lamp with MCB
BUS BARS: 200A TPN bus bars of aluminium alloy.
OUT GOING: 7 Nos. 40A 415V, DP MCB of 10 KA withoverload, short circuit protection.
2 Nos. 32A 415V, DP MCB of 10 KA withoverload, short circuit protection.
Make of MCCB - Legrand -DPX3/ Schneider-NSX//ABB -Tmax
(Complete panel described as above)
1
-
-
Supply, Installation Testing of water prouf termenation cable joint kits with all asscories .
-
-
-
3.5 core 300 sq mm
3
-
-
3.5 core 240 sq mm
4
-
-
3.5 core 150 sq mm
2
-
-
3.5 core 95 sq mm
2
-
-
METER BOARD ASSISTANT PROFESSOR 12 FLATS METER BOARD ASSISTANT PROFESSOR 12 FLATS (TTA Design as per IEC 61439-1/2) Make -(Legrand-XL3/ Schneider-Blokset/ ABB-MNS OEM)
INCOMER : 1 Nos. 400A, 415V, Ics= 50KA, 4P MCCB with overload, short circuit protection.
1 Nos. 0 - 500V voltmeter with selector switch, 0-400A ammeter with selector switch, and set of cast resin C.T.'s 400/5A 2 set of Phase indicating lamp with MCB
BUS BARS: 500A TPN bus bars of aluminium alloy.
OUT GOING: 13Nos. 63A 415V, TPN MCB of 10 KA withoverload, short circuit protection. provision for 3 phase Dual Energy meter with complete connection 2 Nos. 40A 415V, TPN MCB of 10 KA withoverload, short circuit protection. provision for 3 phase Dual Energy meter with complete connection Complete panel described as above
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%