Shri Mata Vaishno Devi University Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Shri Mata Vaishno Devi University - SMVDU Tender

Coronavirus COVID 19
Eprocure
Opening Date13 Nov 2018
Closing Date4 Dec 2018
Tender Amount₹ 63,60,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT for Construction of New Academic Block and Married Accommodation for Scholars at SMVD University, Kakryal, Katra
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Extra for every additional lift of 1.5m or part thereof in excavation / banking excavated or stacked material :All kinds of soil

24514

-

51.75

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

18720

-

125.75

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. For all kinds of soil.

700

-

166.4

... More
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).

350

-

286.3

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete

3360

-

917.75

... More
Supplying chemical emulsion in sealed containers including delivery as specified Chloropyriphos/Lindane emulsifiable concentrate of 20%

1628

-

185.95

... More
Diluting and injecting chemical emulsion ( to be supplied free of cost at site of work) for pre constructional anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor, along the external perimeter of building, expansion joint, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications ( Plinth area of the building at ground floor only shall be measured for payment.) Chloropyriphos emulsifiable concentrate 20% with 1% concentration

-

-

175

... More
Carriage of materials by mechanical transport including loading, unloading and stacking: Earth up to 1 Km. distance

700

-

98.34

... More
Carriage of materials by mechanical transport including loading, unloading and stacking: Earth up to 2 Km. distance

280

-

111.5

... More
CONCRETE WORK (ACADEMIC BLOCK)

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)

922.8

-

4927

... More
REINFORCED CEMENT CONCRETE WORK (ACADEMIC BLOCK)

-

-

-

... More
Providing and laying in position ready mixed M25 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant at site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Fly ash conforming to grade I of IS 3812 (Part-1) only be used as part replacement of OPC as per IS 456. Uniform blending with cement to be ensured in accordance with clauses 5.2 and 5.2.1 of IS:456 -2000 in the items of BMC and RMC. The above item shall be used judiciously where specified quality of Fly Ash is available for mixing in concrete. Also, the guidelines issued by CDO, CPWD, vide circular no. CDO/SE(RR)/Fly Ash (Main)/102 dated 9th April 2009 shall be followed in such cases. All work upto plinth level

4844

-

6691.95

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level All works above plinth & up to floor V level. Note :- The above item shall be used judiciously where specified quality of Fly Ash is available for mixing in concrete. Also, the guidelines issued by CDO, CPWD, vide circular no. CDO/SE(RR)/Fly Ash (Main)/102 dated 9th April 2009 shall be followed in such cases.

8362

-

7495.4

... More
Extra for providing richer mix at all floor levels (Note : Excess / less cement over the specified cement contents use is payable / recoverable separetely.) Providing M30 grade concrete instead of M25 grade BMC / RMC (Note : cement content considered in M 30 is @ 340kg / cum) Extra for providing richer mix at all floor levels (Note : Excess / less cement over the specified cement contents use is payable / recoverable separetely.)

2247

-

69.5

... More
Centering and shuttering including strutting, propping etc. and removalof form for all heights : Foundations, footings, bases of columns, etc. for mass concrete.

2850

-

193.95

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

4373.95

-

378.6

... More
Suspended floors, roofs, landings, balconies and access platform.

23152

-

422.3

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers.

22138

-

422.3

... More
Columns, Pillars, Piers, Abutments, Posts and Struts.

11312.8

-

467.85

... More
Stairs, (excluding landings) except spiral-staircases.

572

-

419.35

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

455

-

171.5

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

-

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

1584720

-

66.6

... More
Providing and fixing tapered / parallel threaded couplers conforming to IS code on Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement – Specification" to reinforcement bars including threading enlargement at connection by forging protecting the prepared reinforcement bars and related operations as required to complete the works per direction of Engineer-in-Charge . (The length of the bars in which coupler is to be provided should not be less than 4 metre no deduction for labour and binding wire saved for not providing lap length shall be made). "

-

-

-

... More
Coupler for 16 mm diameter reinforcement bar.

500

-

121.1

... More
Coupler for 20 mm diameter reinforcement bar.

530

-

164.65

... More
Coupler for 25 mm diameter reinforcement bar.

414

-

227.95

... More
Coupler for 28 mm diameter reinforcement bar.

346

-

314.25

... More
Coupler for 32 mm diameter reinforcement bar.

-

-

364.85

... More
STEEL WORK (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

4500

-

67.6

... More
SHEETING Providing and fixing cold roll formed galvanized profiled sheet from JSW-SMD (TR 80) or Tata Steel (CF 80) with the following specs: Base metal thickness of decking shall be 1 mm thick manufactured using S350 grade of steel with total galvanization of 275 gsm on both sides. The decking is produced in minimum of 60 mm profile depth. The decking is profiled with indentations to achieve adequate bonding with concrete to act as a composite deck.

250

-

900

... More
Providing and fixing Structural steel (black finish) Supply & Fixing of Shear Conector m-19,m-22 & m-25 & 125 & 140 longh conforming AWS 0.11 type B ,Mini tensile 450 Mpa & yield 380, elongation 20%

500

-

65

... More
Providing & fixing of high tension bolt ( black finish) of Grade 8.8s conforming to IS-3757 & IS-4000

500

-

125

... More
Cementitious fireproofing shall be Carboline Pyrolite 15/Grace Monokote MK6/HY applied to provide compliance with all drawings, specifications, and the following performance criteria: The fireproofing shall have been tested by Underwriters Laboratories, Inc. in accordance with the procedures of ASTM E119 and shall be free of asbestos, mineral fibers, polystyrene, or materials which may be considered hazardous either during mixing, application curing, or chemical release in a fire. Mix water shall be potable and free from such amounts of mineral or organic substances that would effect application or set of material. 1. Dry Density: The in place density shall be measured in accordance with ASTM E605. Average density shall be 18 pcf . 2. Bond Strength: When tested in accordance with ASTM E736 over steel, fireproofing shall have a minimum bond strength of 150 psf. 3. Compressive Strength: Fireproofing shall achieve an average value of 2,232 psf when tested in accordance with ASTM E761. 4. Surface Burning Characteristics: Maximum flame spread and smoke development shall be 10 and 0, when tested under ASTM E84. 5. Deflection Resistance: Material shall not crack or delaminate from the surface when tested by ASTM E759. 6. Corrosion: Material shall be 0.00 gms/mm2 of corrosion when tested by ASTM E937. 7. Impact Resistance: Material shall not crack or delaminate from the surface when tested by ASTM E760.

1150

-

850

... More
BRICK WORK (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)

4451

-

5582.85

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:3 (1 cement : 3 coarse sand)

3361

-

708.7

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

3361

-

56.85

... More
Stone / Granite work (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). White sand stone - 30mm thick gang saw cut stone

333

-

1500.7

... More
Supplying, drilling/cleaning hole and fixing of stone façade HC-SF-R SS clamp of 304 hybrid grade.The clamp weight shall be minimum 250gms. Clamp body shall be of 304 grade wherein pin, externally threaded rod, internally threaded tube shall be of 316 grade. The clamp body shall be of minimum 5mm thickness and shall be able to carry a dead load of 79.5 kgs at minimum offset.The clamp shall be available with variable offset lengths from 50-65mm and 80-120mm. Test certificate shall be submitted by the manufacturer, if required. Clamps shall be fastened by HSA-R M10X90 Stainless Steel A4 (316) mechanical torque controlled Stud anchor (on concrete). Anchor should possess ETA approval and should be pre-assembled with a stud, expansion sleeve, a nut and a washer. Top end of stud should contain threads and bottom end should be cold formed conical head . / HRD-HR2 10X100 (on bricks/aerated blocks) . Anchor should possess ETA approval and comprises of polyamide PA 6 grade sleeve and stainless steel A2 (304) grade double threaded screw with hexagonal head. Fixing methodology should be followed as per manufaturer guidelines.

3663

-

320

... More
Providing and fixing Granite stone Wet cladding with 18 mm thick Granite stone slabs fixed flush on 20 mm thick base mortar 1:4 (1 cement : 4 coarse sand) . The granite slabs shall be laid as per approved pattern as shown in the drawings pointed neately with white cement mixed with matching pigment including curing, desired polishing and finishing in all respect at all floor levels and heights complete in all respect as per drawings, specification and directions of Architect / Engineer-in-charge.

1867

-

2800

... More
Providing and fixing Stainless steel cramps of required size & shape in RCC/ CC / Brick masonry backing with cement mortar 1:2 ( 1 cement : 2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately).

1301

-

521.1

... More
Providing and fixing Wedge expansion type expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 6 mm

6005

-

25.25

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm

249

-

3351.95

... More
Providing and fixing stainless steel pins 50 mm long 6 mm diameter (welded to stainless steel cramps described above) for anchoring stone wall lining.

1500

-

500

... More
Providing and fixixng Stone work in copings of approved colour and sample, in cement mortar 1:4 (1 cement : 4 coarse sand) including pointing with white cement mixed with matching pigment and including fixing with stainless steel accesories as shown in the drawings. With 18 mm thick Banswara Marble stone

450.75

-

2400

... More
Providing and fixing 10 mm thick prepolished Granite tile cladding of size 305 x 600 mm fixed flush on 15 mm thick base mortar 1:3 (1 cement : 3 coarse sand) including pointing with white cement mixed with matching pigment including curing, desired polishing and finishing in all respect at all floor levels and heights complete in all respect as per drawings, specification and directions of Architect / Engineer-in-charge.

1746

-

2400

... More
WOOD WORK (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
30 mm thick including ISI marked Stainless steel butt hinges with necessary screws.

1578

-

1559.75

... More
Providing & fixing ISI marked flush doorshutters non-decorative type, core of blockboard construction with frame of 1st classhard wood & well matched commercial 3plyveneering with vertical grains or crossbands &face veneers on both faces of shutters : (a) 35 mm thick including ISI marked Stainless steel butt hinges with necessary screws.

415

-

1559.75

... More
Extra for providing vision panel not exceeding 0.1 sq.m. in all type of flush doors (Cost of glass excluded) (over all area of door shutter to be measured) Rectangular or square

1350

-

162.6

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing & fixing necessary 27.5 cm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters. '80 mm x 1.25 mm M.S. laths with 1.25 mm thick top cover

24

-

2316.1

... More
Providing 40 mm x 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm 'diameter bolts, nuts and wooden plugs and 'embeddings in cement concrete block 30 cm x10 cm x 15 cm with 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).

3360

-

118.6

... More
Providing and fixing 1.0 mm thick laminate on 'both faces of flush door with adhesive BWP 'type synthetic resins conforming to IS : 848 '(single face area of laminate to be measured 'for payment).

4156

-

840

... More
Providing and fixing the following Stainless steel hardware fittings (as approved by the Architects) including necessary screws etc. complete : BALL BEARING HINGES - FIRE RATED Supply of ball bearing hinges of DORMA (BB3090F) /FSB /D-line with 5 Knuckle, 2 bearing butt hinges of size 4" x 3" x 3mm, in SS 304 and in satin stainless steel. As per EN 1935, CE Marked. Suitable for door weights upto 120kgs.Certifying to Green building Compliance

2420

-

302

... More
Supply of DORMA/FSB/D-line Mortise Lockset consisting of Mortice sashlock (Dorma 281a) with 55mm backset, 20mm square forend with 72 mm centers and prepared for euro profile cylinder including strike plate in satin stainless steel finish as per DIN 18251-1, class 3 and SS strike plate with DORMA Lever handle with rose & escutcheons U shape (Dorma ZS8100 Type 1) prepared for Euro profile cylinder in satin stainless steel. Complete set including the fixing accessories for 45-50 mm thick door and Euro profile cylinder (Dorma 3025) with both side key operation standard length 70mm in satin nickle plated finish with 3 keys. Certifying to Green building Compliance

330

-

6200

... More
Supply of DORMA/FSB/D-line Mortise Lockset consisting of Mortice sashlock (Dorma 281a) with 55mm backset, 20mm square forend with 72 mm centers and prepared for euro profile cylinder including strike plate in satin stainless steel finish as per DIN 18251-1, class 3 and SS strike plate with DORMA Lever handle with rose & escutcheons U shape (Dorma ZS8100 Type 2) prepared for Euro profile cylinder in satin stainless steel. Complete set including the fixing accessories for 45-50 mm thick door and Euro profile cylinder (Dorma 3105) with internal thumb turn and external key operation standard length 70mm in satin nickle plated finish with 3 keys. Certifying to Green building Compliance

200

-

6500

... More
Supply of DORMA/FSB/D-line Surface Mounted Door Closer (Model TS73V) (Silver Finish) based on rack & pinion technology with projecting arm (scissor arm) of selectable Spring Size - EN 2-4 with integral self regulating backcheck. Closing speed adjustable by independent valves and Latching Speed adjustable by arm. Door Closer Tested to EN 1154 (5,00,000 Cycles). Door Closer should be suitable for door width upto 1100 mm. Dimension of the Door Closer body - Length - 233 mm, Overall Depth - 42.5 mm and Height - 60 mm & Weight - 1.8 Kg. Non Handed. Standard Fixing of the Door Closer to be done on both (Push / Pull) side of the door.Certifying to Green building Compliance

330

-

7200

... More
Supply of Hanging type Floor Door Stopper of DORMA (4012) /FSB/D-line (with fixing accessories. Dimension - Diameter 30 mm Rubber Cork & Length - 60 mm. Finish : Satin Stainless Steel. Certifying to Green building Compliance

500

-

570

... More
Supply of Wall mounted Door Stop of DORMA (4012) /FSB/D-line (with fixing accessories. Dimension - Diameter 30 mm Rubber Cork & Length - 60 mm. Finish : Satin Stainless Steel. Certifying to Green building Compliance

500

-

550

... More
Supply of DORMA/FSB/D-line lever action flush bolt (Dorma 3101-1) with 19mm projecting bolt L=300mm for Metal door in satin stainless steelCertifying to Green building Compliance.

175

-

850

... More
Fabricating, Providing & fixing at site, the Railing for stairs made out of solid 6 mm thick MS sheets as per design & specifications, complete including profile in required shape with edges rounded and smooth, complete as per drawings and directions of Enginer-in-charge.

810

-

10250

... More
ALUMINIUM WORK (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)

3880

-

391.8

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)

8250

-

452.4

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalization & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised/ Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/ structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory/ work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.

-

-

-

... More
e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal place

-

-

-

... More
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL (National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Online Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35ps) upto 2000ml (S. No. 8.02, 8.03 & 8.04 are the part of this item)

1305

-

2409.9

... More
Extra for providing and fixing openable window (shutter frame) in above Item

60

-

4945

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness

20

-

2228.6

... More
Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. For fixed portion

3880

-

11.6

... More
For shutters of doors, windows & ventilators

6900

-

11.6

... More
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.

2320

-

3176.2

... More
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).

4480

-

408.85

... More
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 Upto 20 mm depth and 20 mm width

2500

-

245.85

... More
GLASS PARTITION WALL (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
Providing and fixing in position Glass partitions along with Glass door compring of the following components : Note : Fixed Partition - EV1 Finish MR28 WCP Glass Frame with Seals 3M Stock Length for 10mm Glass MRL , Stock Length=3000mm 'H" type Alu Profile, 2950mm for 10mm Glass MR28 Corner Connectors MR28/AT50 Corner Connectors MR28/AT50 Corner Connectors b) 1000mm Single Glass Door Fittings with AT50 Frames - EV1 Finish (Package) AT50 Fabricated Frames with Seals & Corner Connectors Junior Office Hinge for frame pivot,complete with sleeve and BB Screw-on Frame Portion, Junior Office with BB Screws for Frame Portion, Junior Office, M4 X 15, CSK Star Head Studio - Rondo, locks adjustable, preared for profile cylinder Studio - Rondo, lever handles Studio - strike plate Euro profile cylinder TS 89 Door Closer G-N Slide Channel TS92 Saddle Plate

150

-

10535

... More
Note : Fixed Partition - EV1 Finish MR28 WCP Glass Frame with Seals 3M Stock Length for 10mm Glass MRL , Stock Length=3000mm 'H" type Alu Profile, 2950mm for 10mm Glass MR28 Corner Connectors MR28/AT50 Corner Connectors MR28/AT50 Corner Connectors b) 1000mm Single Glass Door Fittings with AT50 Frames - EV1 Finish (Package) AT50 Fabricated Frames with Seals & Corner Connectors Junior Office Hinge for frame pivot,complete with sleeve and BB Screw-on Frame Portion, Junior Office with BB Screws for Frame Portion, Junior Office, M4 X 15, CSK Star Head Studio - Rondo, locks adjustable, preared for profile cylinder Studio - Rondo, lever handles Studio - strike plate Euro profile cylinder TS 89 Door Closer G-N Slide Channel TS92 Saddle Plate Installation of above, complete in all respect as per Manufacturer's specifications and directions of Engineer-in-charge.

-

-

-

... More
Fire Doors (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
Providing and fixing Pacific , Godrej, Promat, Kutty Make 2nd class teakwood door frame of section 120 mm x 70 mm of make Pacific , Godrej, Promat, Kutty with heat activated intumescent fire seal strip of section 20 mm x 4 mm of make Sealz ,Pyroplex, Astroflame, and finish with fire retardant polish . The frame will be fix with help of 120 mm long fastner (Paybale in sperate item) complete as per direction by Engineer in charge.

90

-

2148.2

... More
P/f of 57mm thick of Pacific , Godrej, Promat, Kutty Make of 120 minutes fire rating, conforming to BS:476 part 22 IS: 3614 part-II, specifications . suitable for mounting on door frame . The Shutter shall be comprising of 2 non- metallic, asbestos free, fire/smoke check doors Calcium Silicate boards each 12mm thick mm thick double skin Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through HPSC autoclaving process with Compressive Strength 225 kg/sq.cm, Bending Strength 100 kg./ sq.cm , DENSITY 850 KG/M3 TO 900KG/M3.Non Combustible according to BS476 Part 4:1970, surface spread of flame –Class-1, Igniabilty- P (Not easily ignitable), Fire Propagation- Fire propagation Index I- 4.0, Thermal conductivity-K VALUE is 0.15 W/MK sandwiching 25mm thick fire resistant insulation filler faced with 3mm thick commercial ply on both faces with 1mm thick laminate alongwith hard wood lipping all around the shutter with heat activated Intumescent fire seal strip of size 20 mm x 4 mm on all sides except bottom shutter. The shutter will be fixed with the frame with the help of SS ball bearing hinges of size 100x75x3mm of make Assa Abloy , Geze, Hafele ( should be atleast 4 hinges per leaf) complete as per direction of Engineer-in-charge.

45

-

11290.7

... More
Supply of Vision Panel of size 300x600 mm of clear size with 6 mm thick 2 hours fire rated 'Schott Glass' or quivalent at required location on door shutters (as per drawing).

20

-

7500

... More
Providing & fixing of door closers of TS1000 GEZE/ TS-73V DORMA / YALE DCR1824FR EN 2/3/4 , 931.84.749 Hafele Make. (Required For All Fire Doors Except Shaft Door) as per the directions of Engineer-in-charge

10

-

1500

... More
Providing & fixing Push type Yale YPE RM 501P (for single Leaf )+ Yale YPE VR 506PYale (Assa Abloy ) / PHA2000 Series DORMA / 8026344/45 GEZE ,901.02.400 + 901.02.782 Hafele Make Push Panic Bar single / double leaf panic exit devices. (Required For Fire Staircase & Lift Lobby Location Doors Only) as per the directions of Engineer-in-charge Suitable for Double Leaf Shutter

10

-

18200

... More
Flooring work (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
Kota stone slab 25 mm thick in flooring over 25 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with cement mortar 1:4 (1 cement :4coarse sand) on floors, treads and landings.

1556

-

1158.1

... More
Kota stone slab 25 mm thick in risers of steps, skirting dado and pillars laid on 12 mm (average) thick base of cement mortar 1:3 (1cement :3 coarse sand) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.

55

-

1238.2

... More
Mirror polishing on stone slabs wherever required to give high gloss finish complete.

1611

-

231.5

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm

7837

-

1119.4

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm

570

-

1135.2

... More
Providing and laying mirror polished 18 mm thick Granite stone slab in flooring, treads and landings of approved quality, colour and required sizes as specified, selected and sorted for uniformity in colour, free from cracks, fissures and flakes with straight edges and perfect corners laid at right angles over 32 mm (average) thick base in cement mortar 1:4 (1 cement : 4 coarse sand) pointed neately with white cement mixed with colouring pigment to match the shade of slabs at all floor levels and heights.

3189.2

-

3306

... More
Providing and laying Granite in patterned flooring with mirror polished 18 mm thick Granite stone slab in combination with flame finished granite of approved quality, colour and required sizes as specified, selected and sorted for uniformity in colour, free from cracks, fissures and flakes with straight edges and perfect corners laid at right angles over 32 mm (average) thick base in cement mortar 1:4 (1 cement : 4 coarse sand) pointed neately with white cement mixed with colouring pigment to match the shade of slabs at all floor levels and heights.

233

-

4422

... More
Providing and laying mirror polished 18 mm thick Granite stone slab in skirtings and risers of steps of approved quality, colour and required sizes as specified, selected and sorted for uniformity in colour, free from cracks, fissures and flakes with straight edges and perfect corners laid at right angles over 15 mm (average) thick base in cement mortar 1:3 (1 cement : 3 coarse sand) pointed neately with white cement mixed with colouring pigment to match the shade of slabs at all floor levels and heights.

665

-

3494

... More
Making Half bull nosing and making 3 nos. Grooves of size 4x4 mm by disc cutter on Granite Treads / Steps.

1200

-

366

... More
Laminated Flooring Providing and fixing of 12 mm thick adhesive class - 5 commercial grade laminate wooden florring (minimum 6 feet length) of approved make an color. Wooden flooring is fixed with tounge and groove method over 2 mm foam and polythene with click locking system.

3308

-

2300

... More
Water-proofing work (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
Supply and lay foam concrete layer with average density not more than 850kg/m3, and make slopes with averege thicknes 7cm, all according to specifications, conditions and directed instructions by the Engineer

230

-

4500

... More
HORIZONTAL area: GEOTEXTILE : A layer of 150 gsm Geotextile is loose laid on the lean concrete substrate. The geotextile membrane must be overlapped for 75mm. The overlapping joint may be secured by Stitching or Bonding Adhesive or hot air gun as convenient to the waterproofing applicator. : Minimum 500 mm extra to be left all over on the Lean Concrete EPDM membrane : Lying 1.5 mm EPFM Rubber confirming to above mentioned technical values is loose laid over the insulation boards.The width of Firestone EPDM sheet should be minimum 9 meter or large as possible to minimize the number of joints. ( The 9 meter jumbo roll should go through vulcanisation process in automated assembly system for curing ( No manual joining up 9 meter should be done.) Adjacent sheet shall be laid in similar fashion with an overlap of minimum 100 mm . Min 75mm wide rubber polymers butyl splice tape having 100% solid content together with synthetic-rubber polymer primer having 16-18% solids, Specific Gravity 0.793 and Flash point-17.8 degree centigrade, should be used to make watertight QuickSeam between 2 EPDM membranes. 500 mm of EPDM RubberGard is left extra throughout outside the raft area this is to join the membrance with the vertical treatment. Uncured EPDM flashing material factory laminated to splice tape should be used to flash inside and outside corners,pipes, drain outlets, scuppers and other penetrations or unusually shaped walls/details where the use of cured membrance flashing is not pratical PROTECTION Geotextile : 300 gsm shall be laid all

5192

-

1050

... More
Vertical Retaining wall: The surface of retaining wall should be smooth, hard , dry and free from dust before applying treatment. 1.1mm thick EPDM RUBBERGARD confirming to above standards is fully bonded to the RCC substrate using FM approved solvent based Neoprene Bonding adhesive having following parameters. A blend of Acetone, Hexane, Toluene and Xylene; Viscosity; 3,300-3,800 cps, with R.V.F. #3 spindle @ 10 rpm, Weight/Gallon: 6.6-7.4 lb/gal, Specific Gravity: 0.7909-0.8868; V.O.C. Content: 5.282 lb/gal (633 g/l). Bonding Adhesive is used to adhere the membrane to the retaining wall. All the insertions shall be treated with Firestone incurred EPDM. The treatment to be terminated atleast at the height of 300mm above the ground level using termination bar and HD fasteners. Water block sealant should be used on top edge behind membrane and lap sealant should be applied.

1350

-

1296

... More
Retaining Wall Protection Before soil back filling : For the protection of EPDM RubberGard membrance pasted on the retaining wall will be protected with HDPE Dimpled/Studded membrance having weight 500 gram/sqm is Spot stuck on the Bonding Adhesive. The adjacent HDPE membrance should be overlapped for 100 MM NOTE : Soil Back Filling: One the FIRESTONE Waterproofing treatment has been done and HDPE Protection board has been secured Soil Back filling can be done. This is to be done in layers and taking in consideration that is does in layers and taking in consideration that is does not damages the treatment

1350

-

252

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : I) Ist course of applying cement slurry @ 4.40 kg./sq.m. mixed with water proofing compound conforming to IS : 2645 in recommended proportions. II) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water- proofing compound in recommended proportion. III) IIIrd course of applying blown or / residual bitumen applied hot @ 1.7 kg per sqm of area. IV) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100mm wide and pasted to each other with bitumen@ 1.7 kg./sq.m.

1438

-

505.9

... More
ROOF WATER-PROOFING - Surface Preparation Treatment of surface compaction, leveling and cleaning.Provision of smooth, hard and dry and clean concrete surface to receive Firestone RUBBERGARD waterproofing system. The Roof should have adequate slope to drain the storm/rain water towards the provided drainage points. Waterproofing Firestone 1.1 mm EPDM RUBBERGARD on Horizontal and vertical parapet wall of roof Technical parameters FIRESTONE RubberGard: MATERIAL : 1.1 mm thick non reinforced vulcanized EPDM RUBBERGARD meeting ASTM D 4637 requirement. The sheet should be as large as possible but not less than 9 m unspliced width. ( The 9 meter jumbo roll should go through vulcanisation process in automated assembly system for curing ( No manual joining up 9 meter should be done.) Weight - 1.4 kg per sqm, Tensile strength - 9 N/ mm²,Elongation - 300 %, Tear resistance - 35kN/m, Brittleness point - -45 ° C,Water absorption - 2 % Provide EPDM membrane, splice tape, primer and bonding adhesive that are FM approved. Identify materials with FM Approvals markings. All the materials used should be from the same manufacturer. Artificial ageing compliance for more than 7500 hours as per EN 1297 HORIZONTAL area: GEOTEXTILE : A layer of 200 gsm Geotextile is loose laid on the loose concrete substrate. The geotextile membrane must be overlapped for 75mm. The overlapping joint may be secured by Stitching or Bonding Adhesive or hot air gun as convenient to the waterproofing applicator. : Minimum 500 mm extra to be left all over on the Lean Concrete EPDM membrane : Lying 1.5 mm EPFM Rubber confirming to above mentioned technical values is loose laid over the insulation boards.The width of Firestone EPDM sheet should be minimum 9 meter or large as possible to minimize the number of joints. ( The 9 meter jumbo roll should go through vulcanisation process in automated assembly system for curing ( No manual joining up 9 meter should be done.) Adjacent sheet shall be laid in similar fashion with an overlap of minimum 100 mm . Min 75mm wide rubber polymers butyl splice tape having 100% solid content together with synthetic-rubber polymer primer having 16-18% solids, Specific Gravity 0.793 and Flash point-17.8 degree centigrade, should be used to make watertight QuickSeam between 2 EPDM membranes. Vertical Wall : The surface of the wall shall be smooth, hard, dry and free from dust before applying. Waterproofing Protection : One the FIRESTONE Rubberguard treatment has been compleyed as per above then it should e ensured that the treatement is protected by Screed/ Tiles/ stone works etc. weighing not less than 50 kg/sqm.

5842

-

1068

... More
Plain precast cement concrete tiles 22 mm thick jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand). Ordinary cement without any pigment

5475

-

591

... More
Providing & Injecting Injection W.P. system consisting of the following operations : a) Construction Joint Treatment: Supply of Bonding agent cement slurry of Polymer Nano Penetrating Slurry of Activflex ap 105: water: cement: Activguard Concentrate (AC-202) :: 1:3:5:0.25 or equivalent approx. Slurry @ 1 Kg/ Sqm. /COAT to Concreting Contractor Scope. b) Fixing of Nozzle Plastic/ PVC/ GI – threaded: As specified but not below cover depth for rest of stich slab by Providing & Fixing 12mm dia., 75mm (3”) long, PVC/ Plastic/ G.I. Nozzles up to cover depth, by Drill/ Chisel from Inside: Only on construction joints/ honey comb/ cracks at leak areas if any. c) INSIDE WALL: INJECTION GROUTING (AFTER OPENING of SHUTTERS): Pressure grouting non shrink cement slurry at app. 4-7Kg/sq.cm or max @100psi with H.O. pump. d) Bridging construction joints/ Sealing Ghughus (Anchored bars) by Making Fillet(Galta 4”-wide) / Band plaster/ Patch with acrylic/SBR Modified mortar (1:4) added with ACTIVFLEX ap 105 or Equivalent @1% by wt. of cement. e) Crack Sealing of Moment accommodation Factor joints in respect to temp. Variations will be sealed with respective Polysulphide Sealants after making groove cut 10mmX 10mm in dry condition. f) INSIDE WALL : Waterproof Coatings on Retaining wall Providing & Applying Nano Polymer Penetrating Crystalline coats of ACTIVFLEX ap 105 or Equivalent & Modified OPC with AC 202 @ 3Kg./ Sqm. Coatings, IN A MANNER TO GET TWO( 2) COATS & SPLASH for FURTHER PLASTER (If required for Finishing may be, by other Agency, i.e. main contractor, we will provide w/p additive for water tank if need so. g) Grouting & Sealing of all incoming & Out Going Pipes, with suitable Grout & Sealant. INSIDE WALL: INJECTION GROUTING (AFTER OPENING of SHUTTERS, Waterproof Coatings on Retaining wall Providing & Applying Nano Polymer Penetrating Crystalline coats Grouting & Sealing of all incoming & Out Going Pipes, with suitable Grout & Sealant

2998.8

-

422

... More
Finishing work (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
12 mm cement plaster of mix : '1:6 (1 cement : 6 fine sand)

14687

-

160.35

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : '1:6 (1 cement : 6 fine sand)

-

-

185.2

... More
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1Cement : 5 coarse sand) and a top layer 6 mm thick cement plaster '1:3 (1 cement : 3 fine sand)

-

-

272.05

... More
6 mm cement plaster to ceiling of mix: '1:3 (1 cement : 3 fine sand)

18300

-

252.4

... More
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

14687

-

174.7

... More
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats

17472.2

-

49.65

... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats

7200

-

71

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

19176.9

-

96.8

... More
Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats

1000

-

75

... More
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre

1000

-

38.45

... More
With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre

600

-

32.55

... More
With ready mixed red oxide zinc chromatic on steel / iron works having VOC content less than 250 grams/ litre

2000

-

36.95

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufac-turer's specifications including appropriate priming coat, preparation of surface etc. complete.

-

-

-

... More
On steel work

200

-

122.5

... More
On concrete work

1180

-

124.5

... More
Providing and fixing 1st quality ceramic glazed tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all coluors, shades except burgendy, bottle green, black of any size as approved by the Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sq-m including pointing in white cement mixed with piment of matching shade, complete.

3290

-

744.8

... More
Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building.

1950

-

425.1

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.

3550

-

1163.9

... More
Providing and fixing modular passivated stainless steel staircase system conforming to AISI 304 of following sizes of members with necessary riveting and investment casted components compatible to Stainless steel pipe dia. 42.3 mm O.D. x 1.6 mm thick Top rail by fixing sides of staircase flight using Stainless steel pipe dia. 42.3 mm O.D. x 2.0 mm thick balusters at every third step and 3 nos. 16 mm dia. stainless steel mid rails passing through 30 mm dia. stainless steel sockets fixed on to the balustrade, including stainless steel shoes bolted on the side on each baluster complete at all floors and levelas per drawing nos. 6/08, 6/09, 6/10 and 6/11.

1700

-

8800

... More
Sky Light Roof (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes.

3700

-

90.25

... More
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

1000

-

85.85

... More
Providing and fixing of Minimum 16mm thick Multicell having min. 50 microns Co-extruded UV protected on top Layer (exposed to Sun) over structural steel / MS purlin as per approved colour/shade. Panels shall have width of 600mm – 1000mm to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Polycarbonate Panel System with minimum 5 cells and 6 walls structure shall be uniform in colour with an integral Tight-Cell not to exceed 4.3mm x 4.3mm with cross section., with all fixing accessories to ensure best performance for wind uplift, vibriation, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel.  Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on purlins with Stainless steel retention clips and connectors. Snap-on connectors to interlock the panels shall have a grip-lock Single/double tooth locking mechanism to ensure maximum uplift capability.Whole system shall be secured with end caps, breather tapes, Aluminium U profile or F profiles having drainholes to let rain water flow out without affecting the panel system, as per the site requirements. The weight of the panel only shall not be less than 3.3 kg per square meter( SS retention clip/SS fastener , PC end Cap and Aluminium UPD weights are not included in the above Weight). Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 750 Hours as per ASTM G 155 or Equivalent test by any NABL Approved Labs., complete as per directions of Engineer-in-charge.

540

-

4028

... More
SANITARY FIXTURES & FITTINGS (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
Providing and fixing Wall mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/ make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.

120

-

12612.65

... More
Providing and Fixing 2 Nos. support arms and backrest of 35 mm dia Stainless steel body to be mounted on the track (vertically and laterally) for handicap toilet complete as required.

25

-

2500

... More
Providing and Fixing raised toilet seat cover for handicap toilet.

10

-

2500

... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.

120

-

254.8

... More
Providing and fixing Above Counter wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Above Counter Wash basin size with a pair of 15 mm C.P. brass pillar taps.

135

-

2298.55

... More
Providing and fixing stainless steel A ISI 304 (18/8) Kitchensink as per IS : 13983 with CI bracket and stainless steel plug 40 mm including painting of fittings and brackets ,cutting and making good the walls wherever required: Kitchen sink with drain board 500 x 1040 mm bowl depth 200 mm

50

-

3772.35

... More
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia

50

-

4715.15

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.

135

-

795.15

... More
Providing and fixing uplasticized connection pipe with brass union: 45 cm length 15 mm nominal bore

-

-

67.8

... More
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm

-

-

752.8

... More
Providing and fixing CP Brass Shower rose with 15 or 20 mm inlet - 100 mm diameter

50

-

71.65

... More
Providing and fixing CP Brass Stop Cock (Concealed) of standard desgin and of approved make confirming to IS 8931 15 mm nominal bore

20

-

545.95

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore.

42

-

371.7

... More
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore.

20

-

555.3

... More
Providing and fixing CP Brass Towel Rail complete with bracket fixed to wooden ckeats with CP brass crew with concealed fitting arrangements of approved quality and colour 600MM long tower rail

50

-

1500

... More
Providing and fixing CP Brass soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 156 gms.

120

-

1000

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore

-

-

475.7

... More
Providing and fixing toilet paper holder : CP Brass

-

-

385.35

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required One urinal basin with 5 litre white P.V.C. automatic flushing cistern

52

-

5162.2

... More
INTERNAL DRAINAGE (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
Supply, installation , testing & commissioning of UPVC SWR Pipe (ring type) Class B and fitting confirming to IS 14735 for soil , waste and vent pipe and Rain water downtake pipe conforming to IS:13592 cut to required lengths including door piece, bends, tee, y-tee, plain tee, door tee and all necessary fittings and specials. Cost shall be inclusive of providing and Fixing of pipes and fittings at wall/ceiling level with all type of supported by MS hot dipped galvanised angle support for vertical and horizontal pipe fixing with GI u clamp & hangers etc. Making proper connection with cement solvent joint as per BIS / manufacturer. Cutting chases/holes in floors/walls/slab etc. The vertical downtake shall be supported with thrust block. Contractor shall submit support details for approval prior to execution of works at site. 75 mm dia

408

-

650

... More
Supply, installation , testing & commissioning of UPVC SWR Pipe (ring type) Class B and fitting confirming to IS 14735 for soil , waste and vent pipe and Rain water downtake pipe conforming to IS:13592 cut to required lengths including door piece, bends, tee, y-tee, plain tee, door tee and all necessary fittings and specials. Cost shall be inclusive of providing and Fixing of pipes and fittings at wall/ceiling level with all type of supported by MS hot dipped galvanised angle support for vertical and horizontal pipe fixing with GI u clamp & hangers etc. Making proper connection with cement solvent joint as per BIS / manufacturer. Cutting chases/holes in floors/walls/slab etc. The vertical downtake shall be supported with thrust block. Contractor shall submit support details for approval prior to execution of works at site. 110 mm dia

-

-

950

... More
(a) 40 mm dia (6 bar pressure rated)

710

-

350

... More
(b) 50 mm dia (6 bar pressure rated)

248.4

-

525

... More
(C) 110 mm dia (6 bar pressure rated)

-

-

975

... More
(D) 160 mm dia (6 bar pressure rated)

1179

-

1250

... More
Supply, installation , testing & commissioning in position SWR PVC P trap of self cleaning design of following sizes for the embedded areas with minimum water seal of 70 mm. Making proper connection with. Cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required. a) 110mm inlet and 110mm outlet

198

-

650

... More
Supply, installation , testing & commissioning PVC saddle for connecting two or three inlet waste connection of 32/40 and 63mm nominal dia , including cutting and chasing as required to complete the job.

198

-

350

... More
Supply, installation , testing & commissioning 100mm x 63mm PVC waste reducing elbow including cutting chases, making holes in the floor / slab, repairs complete as required and connection to pvc pipes

-

-

350

... More
Supply, installation , testing & commissioning upvc floor/ceiling clean out plug with suitable inlet key for opening male threaded joint with UPVC pipe & socket. Including socketed joint complete as per approved specifications. For 110 mm dia pipe

64

-

1250

... More
Supply, installation , testing & commissioning upvc floor/ceiling clean out plug with suitable inlet key for opening male threaded joint with UPVC pipe & socket. Including socketed joint complete as per approved specifications. For 160 mm dia pipe

49

-

1550

... More
Supply, installation , testing & commissioning Heavy class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for FD and FT. a) Size 100 mm x 100 mm.

-

-

3500

... More
Supply, installation , testing & commissioning of 150 mm diameter SS -304 grating for rain water verticals including cement mortar for fixing at roof level complete as required.

42

-

650

... More
DOMESTIC WATER SUPPLY (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer in charge. Internal work - Exposed on wall (a) PN - 16 Pipe, 16 mm OD

-

-

128.9

... More
(b) PN - 16 Pipe, 20 mm OD

631.5

-

166.55

... More
(c) PN - 16 Pipe, 25 mm OD

725.5

-

220.75

... More
(d) PN - 16 Pipe, 32 mm OD

541

-

314.8

... More
(e) PN - 16 Pipe, 40 mm OD

814

-

450.15

... More
(f) PN - 16 Pipe, 50 mm OD

783

-

631.35

... More
(g) PN - 16 Pipe, 65 mm OD

1149

-

900

... More
(h) PN - 16 Pipe, 80 mm OD

184

-

1250

... More
Providing and fixing Polyethelene-Aluminium- Polyethelene (PEALPE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge. Concealed work, including cutting chases and making good the walls etc., (a) PN - 16 Pipe, 16 mm OD

1520

-

233.4

... More
(b) PN - 16 Pipe, 20 mm OD

1194

-

274.05

... More
(c) PN - 16 Pipe, 25 mm OD

818

-

337.05

... More
(d) PN - 16 Pipe, 32 mm OD

250

-

446.8

... More
Supply, installation , testing & commissioning of Nytril Rubber Insulation and polyshield outer mechanical protection (comprising of wrapping with poly glass tape helically wound and subsequently applying 2 coats of polyshield material (resin & hardner) as per manufacturers specification) on Hot and chilled water supply lines having thermal conductivity .038 W/mok 0.212 BTU / (Hr-ft2-oF/inch) at an average temperature of 30oC ,temperature range of –40oC to 105oC,Density of material shall not be less than 0.06 gm/cm3, class O type, complete as per manufacturer recommendation. (a) 15 mm dia. nominal bore

230

-

150

... More
(b) 20 mm dia. nominal bore

300

-

165

... More
(c) 25 mm dia. nominal bore

290

-

195

... More
(d) 32 mm dia. nominal bore

160

-

225

... More
Providing & fixing full way lever operated Brass ball valve of brass body with stainless steel ball conforming to IS 778 with threaded / flanged joints (PN 16) complete with nuts, bolts, gaskets, washers and fixing to supports etc.(PN 16) (a) 20 mm nominal bore

93

-

1550

... More
(b) 25 mm nominal bore

169

-

1950

... More
(c) 32 mm nominal bore.

46

-

2250

... More
(d) 40 mm nominal bore

68

-

2850

... More
(e) 50 mm nominal bore

40

-

3500

... More
Providing & fixing butterfly valve conforming to IS 13095 (Body : Grey Cast Iron, Shaft : SS, Disc : SS, Liner : HT - EPDM) (upto 150mm dia with hand lever operation & above with gear box operation). Including rubber gasket, flanges(PN 16), nuts, bolts, washers & painting complete as required as per specification.(PN 16) (a) 65 mm nominal bore

13

-

4500

... More
(b) 80 mm nominal bore

18

-

5500

... More
(c) 100 mm nominal bore

6

-

6500

... More
Providing and fixing in position of approved quality high pressure rated Gun Metal Float Valve with copper ball float and brass rods of required length of the following sizes: 15 mm nominal bore

8

-

2500

... More
Providing & fixing dual flanged C.I. `Y' Strainer with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. (a)65 mm dia

4

-

7000

... More
(b) 80 mm dia

4

-

8000

... More
(c) 100 mm dia

4

-

8500

... More
REVERSE OSMOSIS TREATMENT STATION (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
Supply, Installation, Testing & Commisioning of Reverse Osmosis unit of following capacity to treat the raw water having TDS 1200 ppm and reducing TDS to 100ppm and hardness less than 50 ppm or as per WHO standards. The operating voltage to 230 volt AC +/- 10%. Potable water system components shall comply with Safe Drinking Water Act Amendments, the 1988 Lead Contamination Control Act and shall be to ANSI/NSF 61 Section 9. Contractor shall require to submit test report post installtion of RO plant and cost shall be inclusive of 15 days training to engineer incharge. 1. Pre and Post treatment Dosing System (each consisting of one HDPE tank of 200 litres capacity with a positive displacement diphragm dosing speed & stroke control pump (1W + 1S) having variable flowrate of 0-6 lph. The motor shall be suitable for operation at 240 V/Single phase/50 Hz. Supply. The pump shall be supplied complete with necessary agitator, polypropylene piping, valves, strainers, low level switch(Range 0-600mm) and injection fittings.): a) Biocide dosing system for pre and Hypochlorite and soda ash post dosing and dosage rate 2-3 mg/l. b) Anti scalant dosing system for dosing downstream of MGF and ACF and dosage rate 5 mg/l. c) Acid dosing system in inlet of RO membrane and dosage rate 2 mg/l. d) SMBS dosing system for dechlorination at the inlet of RO membrane and dosage rate 5-10 mg/l. e) PH Correction Dosing system(NaOH) for maintaining the ph to drinking water standard. Dosage required will be 2 mg/l. 2. Pre-Filtration System a) Multigrade and Activated Carbon Filtration system : FRP filter complete with initial charge with pebbles, anthracite, media , connecting with multiport valve (for controlling all operations for rinsing, backwashing, service etc under automated system linked with differential pressure transmitter and differential guage), glycerine filled pressure gauge at inlet, outlet and back wash (each with isolation cock), complete as required with sand blasted inside and outside, finished with 6-8 mm thick epoxy lining reinforced and including wiring and anunciation complete as requiredincluding all other accessories required to make the system complete as per the specifications. b) Softner System c) CIP System

-

-

-

... More
3. Reverse Osmosis System: a) High Pressure Pump(1W+1S): Vertical centrifugal Pump with low pressure switch for smooth operation, dry run protection of adequate capacity and head with SS AISI 316 stage casing, AISI SS 316 impellors, SS Suction chamber, SS 316 Pump shaft, steel base plate, carbon mechanical shaft seal and suction and discharge casing as per IEC standards, connected to TEFC Ventilated induction motor of 2 pole, 2900 RPM, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply with glycerin filled pressure gauge , vibration elimination pads, dry run protection etc. complete with base and frame, nuts and bolts. The pump should be rated at the premium efficiency rating of IE. The pump inclosure to be minimum IP 54 rated and insulation class to be F. b) Reverse Osmosis Block comprising of micron filter and membrane encased inside pressure vessels. the membrane to be thin film composite in spiral wound construction. Membrane material to be TFC Polyamide.RO Housing to FRP material with pressure rating of 250 psi. The treatment station to be PLC based fully automated system. The item includes all necessary instruements like level indicators switches, solenoid valve at blending line, control cables etc to complete the system. 1500 LPH

3

-

650000

... More
Supply, installation , testing & commissioning of SS water tank for drinking water and kitchen storage , tank shall be provided with Inner layer SS316 + Outer Layer SS 304 of specified thickness, tank should be provided with inlet, outlet and vent/overflow connection, 75mm Puf Insulation , manhole cover 450mm dia, Inlet connection of water tank shall be of 25mm nominal bore, overflow/vent - 25mm nominal bore and outlet connection at bottom of tank of 40mm nominal bore. Cost of tank shall be inclusive of Angle stiffeners,stand leg, SS flanges connecting from water treatment facility and distribution system complete as per approved specifications. ( contractor shall provide drawing to civil contractor for tank foundation) ( Thickness of inner layer 0.8mm & outer layer .6mm) 3000 Liters tank capacity

3

-

150000

... More
Supply, installation , testing & commissioning of high efficiency Storage water cooler / Dispenser of follwing capacities with water at 15°C cooled from 40°C inlet water at 35°C ambient. Evaporator shall be high tank type and shall be encapsulated in insulation. R-404 refrigerant system shall be hermetically sealed and refrigerant shall be capillary tube controlled. An adjustable thermostat having an off position shall control refrigeration system. Cabinet shall be galvanized steel. Potable water system components shall comply with Safe Drinking Water Act Amendments, the 1988 Lead Contamination Control Act and shall be to ANSI/NSF 61 Section 9. chiller should be single phase 220 V, 50 Hz, with cooling coil, heavy gauge galvanized steel complete as required including foundation, complete as required. Cooling capacity : 80 lts/hr.

12

-

45000

... More
Supply, Installation, Testing And Commissioning Of Compact Self Contained Skid Mounted Hydropneumatic System As Follows: a. Vertical, In-Line, Multistage, centrifugal pumps with SS-304 casing and impeller and SS-316 shaft, CI base & head TEFC motor (with mechanical seal) (Vendor to submit performance curves and technical catalog of the proposed model for review & information) a. The pump shall be selected for performance at best efficiency point. However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head. b. External Pump mounted or wall mounted microprocessor PID controller and frequency inverter integrated in a single body or as separate components with pressure sensor transmitter minimum two lined LCD display, diodes to indicate pump ready, pump running and fault and capable to communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocall through RS485 port. System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equiped with dry running protection - Quantity : 1 No. ( BMS compatilble with RS 485 port) c. Complete (Skid mounted wall mounted / floor mounted) electrical control panel comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiring and any other necessary imports etc. (list to be provided by the vendor) d. Precharged diaphram pressure vessel with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc complete. e. Set of accessories such as pressure switches, pressure transducers, inter connecting power and control cabling etc. complete f. Accessories like pressure gauge, MS base frame (Synthetic enamel painted over a coat of primer) g. SS suction and delivery header with flanges for inlet connection, common outlet header with flanges for outlet connections as required, and inter connecting piping with flexible connections, eccentric type reducers etc. all necessary indigenous accessories as required to complete the installation. Head 25 M

-

-

-

... More
Note: Contractor to note that the suction header is required to have inlet connection from the Puddle Flange @ water tanks and to the pump suction. Provision of delivery header is required to have outlet connection from the pumps. Suitable outlet flanges from the delivery mainfold / header shall be provided as required. Pump shall be capable of delievering adequate flow at 20% increased flow & 10% reduced head. Hydro-pneumatic Pumps for Domestic water supply No. of pumps 3 (2 Working + 1 Standby) Water Flow Rate 2 LPS each

2

-

450000

... More
EXTERNAL SEWER AND STORM (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m Make: Astral / Supreme / Finolex Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.

-

-

225.45

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), ncluding dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

70

-

166.4

... More
Providing and fixing of uPVC SDR pipes as Under ground Sewerage Pipes as per IS 15328-2003 for underground non pressure applications , placing in trench , jointing the pipes with solvent cement as per manufacturer's specifications complete as per specifications and as directed by the Engineer - in - Charge, Class of pipe - SN6 (Stiffness Class 6KN/m2). PCC for bedding, haunching or all round the pipe, excavation and backfilling shall be payable separately under relevant head,.(PCC bedding, all round and upto haunching shall be paid separately) (a) 150 mm diameter

205

-

350

... More
(b) 250 mm diameter

-

-

650

... More
(c) 300 mm diameter

380

-

850

... More
Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches for pipes including bed concrete as per standard design. (a) 150 mm dia.

160

-

479.85

... More
(b) 250 mm dia.

515

-

656.6

... More
(c) 300 mm dia.

365

-

757.6

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type With modular bricks conforming to IS : 4885

40

-

1640.35

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885

50

-

8678.85

... More
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : (a) With Sewer bricks conforming to IS : 4885

8

-

18544.9

... More
(b) Extra for depth for manholes : Size 90x80 cm With Sewer bricks conforming to IS : 4885

11

-

5848.95

... More
(c)Size 120x90 cm With Sewer bricks conforming to IS : 4885

8

-

7006.1

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar Conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

314

-

327.9

... More
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 5.0

70

-

4043.1

... More
Constructing Disiltling chamber/Oil Trap of brick work with bricks of class 75 with cement mortar 1:5 (1 cement:5 fine sand) plastering internal face with cement mortar 1:3 (1 cement: 3 fine sand and rough plaster on outer face with a floating coat of neat cement. R.C.C top slab with medium duty CI manhole cover and frame of 600 mm dia. The weight of cover to be not less than 58 kg & frame not be less than 58 kg as per standard design. Including excavation, dewatering, refilling, watering, ramming and removing the surplus excavated material complete as required. (All sizes are clear internal sizes). Depth shall be as per actual site condition and invert level. Size 1500 x 1000 x 1000 mm water depth (Total Depth shall be as per invert level of site)

2

-

25000

... More
Providing and executing modular harvesting pit of recycled polyprpylene material with crush load capacity of 20-25 tons per square metre and load bearing strength of 40 tons. The pit shall be wrapped with geotextile faabric material to prevent soil insertion and effective insertion of sorrounding water. The Geotextile material shall be UV resistant and conforming to ASTM 154/EN 12224.the cost shall be inclusive of all necessary excavation in all kind of soils,boring upto aquifier, refilling and disposal of surplus earth with in the site or away from site as directed with out any extra cost including required nos. 750 x 750 mm, Medium Duty , Wt : 125 kg, Ductile Iron cover with frame for Filter chamber. (All sizes are clear internal sizes). Depth shall be as per actual site condition and invert level. Size- 4 mtr. x 4 mtr. 2.5 mtr. water depth WD

2

-

650000

... More
Providing and Fixing Grease Separator plant as per DIN EN 1825 / PDI certified recessed or floor mounted spoxy coated steel grease interceptor with gasketted solid steel cover, hex head centre bolts, removable baffle assembly, deep seal trap with clean out, no hub connections & external cast iron flow control fittings, with manhole cover, 1 set of operating keys, nominal connection size 75mm, odour proof sealed, with direct suction pipe, along with all necessary accessories and equipment complete including necessary foundations, civil works and finishing as per site requirements and as per instructions of the engineer in charge.This shall be provided with sediment bucket epoxy coated steel located inside the interceptor on inlet side, collects large food or other particles, to the extent possible, sediment should be strained or collected at the fixture prior to the grease interceptor, sediment entering the waste line is likely to clog the interceptor flow restrictor, slowing drainage, and causing backup difficulties, Heavy duty traffic cover rated 10,000 lbs. , flange and clamp device complete as required or approved by EIC/ manufacturer recomendations (Rate shall be for complete system including all necessary taxes, duties, levies etc.) (Grease storage capacity 285 ltrs, total waste water capacity 1675 ltrs, with integrated sludge trap of 730 ltrs capacity)

1

-

350000

... More
EXTERNAL WATER SUPPLY (ACADEMIC BLOCK & MARRIED ACCOMODATION)

-

-

-

... More
(a) PN - 16 Pipe, 25 mm OD (SDR - 7.4)

45

-

198.95

... More
(b) PN - 16 Pipe, 50 mm OD (SDR - 7.4)

750

-

573.95

... More
(c) PN - 16 Pipe, 63 mm OD (SDR - 7.4)

40

-

862.9

... More
(d) PN - 16 Pipe, 75 mm OD (SDR - 7.4)

30

-

1145.25

... More
(e) PN - 16 Pipe, 90 mm OD (SDR - 7.4)

170

-

1726.5

... More
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

20

-

1195.35

... More
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : (a) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

2

-

11842.65

... More
PUMPS AND ELECTRO-MECHANICAL ACCESSORIES Supply, installation , testing & commissioning Single/multistage monoblock pumping set with stainless steel CI stage casing and SS-304 impellers with stainless steel shaft and suction & discharge casing as per IEC standards , connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply with pressure gauge and with gunmetal isolation valves, vibration elimination pads etc. complete with base and frame, nuts and bolts. All valves, RCC foundations and foundation bolts shall be paid seperately under relevant heads as per requirement and as per instructions . The vender shall submit performance curve and technical data sheet to the consultant prior to installation. The head versus discharge curve shall be on the rising side. including termination of cables on motor. Nos. of Pumps :2 Nos (1w+1s) Water Flow Rate : 5 LPS each pump Head : 50 M

1

-

165000

... More
PUMPS AND ELECTRO-MECHANICAL ACCESSORIES Supply, installation , testing & commissioning Single/multistage monoblock pumping set with stainless steel CI stage casing and SS-304 impellers with stainless steel shaft and suction & discharge casing as per IEC standards , connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply with pressure gauge and with gunmetal isolation valves, vibration elimination pads etc. complete with base and frame, nuts and bolts. All valves, RCC foundations and foundation bolts shall be paid seperately under relevant heads as per requirement and as per instructions . The vender shall submit performance curve and technical data sheet to the consultant prior to installation. The head versus discharge curve shall be on the rising side. including termination of cables on motor. Nos. of Pumps :2 Nos (1w+1s) Water Flow Rate : 5 LPS each pump Head : 40 M

1

-

155000

... More
Submersiable Centrifugal Non-clog Drainage Pump - Supply, installation, testing and commissioning of continuous duty submersible centrifugal non-clogging drainage/sewage pumps complete with 3 phase motor with all necessary protection and mechanical seal etc. complete with all ancillaries including float type level controllers, electrical control panels fabricated from 14 gauge CRCA sheet volt meter ammeter with selector switch, TPMCB, 5 VA CL : CTs, phase indicating lamps protected by 2 amp SP MCB, DOL starter, necessary wiring, cable alleys, earthing, interlocking, starter with Automatic float type level controller, providion of high level alarm, sequence timer, potential free contact to starter for connection to BAS, both pumps may run simultaneously at pre determind level. Vendor to submit proposed pump model with duty curve. Nos. of Pumps : 2 nos (1 w+ 1 s) Water Flow Rate : 4 LPS each pump Head : 15 M Location : Drainage Sump Pump for Plant room

2

-

95000

... More
Submersiable Centrifugal Non-clog Drainage Pump - Supply, installation, testing and commissioning of continuous duty submersible centrifugal non-clogging drainage/sewage pumps complete with 3 phase motor with all necessary protection and mechanical seal etc. complete with all ancillaries including float type level controllers, electrical control panels fabricated from 14 gauge CRCA sheet volt meter ammeter with selector switch, TPMCB, 5 VA CL : CTs, phase indicating lamps protected by 2 amp SP MCB, DOL starter, necessary wiring, cable alleys, earthing, interlocking, starter with Automatic float type level controller, providion of high level alarm, sequence timer, potential free contact to starter for connection to BAS, both pumps may run simultaneously at pre determind level. Vendor to submit proposed pump model with duty curve. Nos. of Pumps : 2 nos (1 w+ 1 s) Water Flow Rate : 4 LPS each pump Head : 15 M Location : Drainage Sump Pump for Basement

4

-

95000

... More
Supply, installation , testing & commissioning of Water level indicators cum controllers of Stainless Steel Probe with Digital display panel for installation on storage tanks, and capable of providing 4 to 20 mA analog signal compatible with PLC signal inputs ( probe should be provided with 20m cable with no connection joints in single run) and complete as per working requirements . All analog output from probe should be indicated in digital output panel placed in MCC panel and wiring should be done for interlocking , auto start / stop of pump complete as per specifications

10

-

25000

... More
Supplying, Installation, Testing and Commisioning of online TDS meter suitable for fixing at domestic /drinking water treatment station for online monitoring of water quality and inlet and oulet, equipment shall be provided with Built-in non-volatile memory,local display, Automatic Temperature, Compensation, Password Protected, IP - 67 rating, measuring range 0 to 1000 ppm , including cable termination for controlling and alarming complete as per specifications ( cost of cabling and end termination shall be paid under relevant subhead)

2

-

25000

... More
Supplying, Installation, Testing and Commisioning of online PH meter suitable for fixing at domestic water treatment station for online monitoring of water quality and inlet and oulet, equipment shall be provided with Built-in non-volatile memory,local display, Automatic Temperature, Compensation, Password Protected, IP - 67 rating, measuring range 0 to 14 , including cable termination for controlling and alarming complete as per specifications ( cost of cabling and end termination shall be paid under relevant subhead)

2

-

25000

... More
Supply, installation , testing & commissioning of electronic water meter with direct reading dial in KL with all internal parts in gunmetal or brass, flanged distance piece for easy removal in future, strainer, 100mm dia Bourden type pressure gauge and isolation cock complete in all respects. (a) 80 mm dia nominal bore for Borewell water supply

2

-

11000

... More
(b) 65 mm dia nominal bore for Domestic water supply

2

-

11000

... More
Supply, installation , testing & commissioning of 600 mm long MS hot dip galvanized Puddle Flange fabricated out of 6 mm thick MS plates of suitable size and IS:1239 heavy class pipes properly fixed in walls / top slab of tanks. The entire fittings shall be hot dipped galvanized after fabrication. Length shall be minimum 600 mm or wall thickness plus 200 mm on either side (which ever is more). (a) 32 mm dia

10

-

2200

... More
(b) 50 mm dia

10

-

2550

... More
(c) 65 mm dia

10

-

3100

... More
(d) 80 mm dia

8

-

3500

... More
(e) 100 mm dia

10

-

4100

... More
(f) 150 mm dia

10

-

5860

... More
Supply, installation , testing & commissioning of mosquito proof brass overflow grating for underground/overhead water tanks. 100 mm dia

10

-

2100

... More
Supply, installation , testing & commissioning of insect vermin -proof coupling to vent pipes of underground tank/overhead tank with threaded or flanged joints, including M.S. flanges, nuts, bolts, 3mm thick rubber insertions complete. 100mm dia

10

-

3500

... More
Supply, installation , testing & commissioning of suitable flexible neoprene rubber expansion joint, single arch with integral rubber flanges with SRR drilled as per BS-10, Table-D, complete. (a) 65mm dia

8

-

3500

... More
(b) 80mm dia

8

-

4500

... More
PLUMBING PANELS Design, Fabrication,Supply, Installation, Testing and Commissioning of following Wall mounted / Floor mounted(including base stand), 415V,3PH, 50Hz extensible and fully compartmentalized panels complying to IS 8623/93. The indoor panels shall be IP 42 and outdoor panels shall be IP 54 type.The Panel shall have proper space with required clearance for cables, incoming / outgoing switchgear, CTs, PTs, ammeter, Voltmeter, selector switches, Insulated and properly supported compartmentalized bus bars with heat shrinkable sleeves along with the other control circuit accessories within the panel and any other electrical component mentioned in the Panel SLD.The panel shall be fabricated out of CRCA not less than 2.0 mm thick for load bearing members and 1.6mm for the doors of LT panel.The Panel shall have seven tank pre treatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having a paint thickness of 60 microns or as specified.The Panel shall be Dust/Vermin poof with earth studs as per the SLD and specifications, Panel should be BAS compatible. Refer the SLD for relevant information. MCC Panel -1 ( Plant Room) Incomer : 1 x R,Y,B LED indication lamp with 2A control MCB 1 x 100 A, FP, 16 kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with thermal magnetic based release. 1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KVAR, PF, KWH, V, A with 3X100/5A, 5VA Class 1.0 CTs) Busbar : 150A, 415V, FP, 16 kA/1sec, Aluminium busbar. Outgoings : 6 x 63 A, FP, 10kA, MCB "C Curve". 6 x 40 A, FP, 10kA, MCB "C Curve". Starter for Pumps in the description above are included in the scope of this item as per the relevant design and type 2 coordination chart. All starter to be DOL. The item is inclusive of all cable end terminations, power and control cables(Inside Plant room, deck area and upto heat pump at terrace), cable trays, conductor and all necessary items required to complete the system and in accordance with the engineer in charge. Make: Cable & Wire

2

-

450000

... More
FIRE PUMPS AND ACCESSORIES Supply, installation, testing and commissioning of electrically driven high pressure centrifugal fire hydrant / sprinkler pump, suitable for automatic operation consisting of the following: Horizontal Spilt casing, centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ A.C supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have C.I. casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) and S.S. (304) Shaft with mechanical seal, capable for delivering 2280 LPM at outlet head of 80 mts to ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmost hydrant / sprinkler. The installation shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. (The pump should be tested for bench mark at factory and shall be gotten approved by the Local fire Authority). Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head. Squirrel cage induction motor, TEFC type suitable for operation on 415 volts, 3 phase 50 HZ A.C supply, for the above pump with synchronous speed of 2900 RPM, conforming to IP 55 protection & class F insulation. The motor shall conform to IS 325-1978 (up to date) with flexible coupling and coupling guard, complete as required. c. Common base plate for (a) and (b) from M.S. Channel for required size. d. Anti-vibration arrangement of cushy foot mountings.

1

-

350412.8

... More
Supply, installation, testing and commissioning of Diesel Engine driven fire pump suitable for automatic operation comprising of the following and conforming to BS 649/IS 10002 all amended upto date. Horizontal spilt casing centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ A.C supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have C.I. casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) and S.S. (304) Shaft with mechanical seal, capable for delivering 2280 LPM at outlet head of 80 mts to ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmost hydrant / sprinkler. The installation shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. (The pump should be tested for bench mark at factory and shall be gotten approved by the Local fire Authority). Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head. b. Heat exchanger cooled (secondary cooling) diesel engine of speed 1500 RPM suitable for the above pump with automatic starting mechanism and other accessories including fuel tank (fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of primer) of capacity adequate to sustain pump operation for 8 hours continuous working. The tank shall be fitted with Magnetic oil level indicator, MH with cover, drain valve, air vent including structural supports (painted with approved shade), 2 Nos. x 12 volt battery, heat exchanger with necessary piping connections & fittings, flexible coupling, coupling guard & exhaust pipe connection complete as required. c. Common base plate for (a) and (b) from M.S. channel of required size. d. Antivibration arrangement of cushy foot mountings. Supply, installation, testing and commissioning of Diesel Engine driven fire pump suitable for automatic operation comprising of the following and conforming to BS 649/IS 10002 all amended upto date.

1

-

650342.4

... More
Supply, installation, testing and commissioning of jockey pump (pressurisation pump) comprising of the following: a. Horizontal mono-block Pumps, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ A.C supply. The installation shall be complete with Flexible coupling and coupling guard, complete as required. Jockey pump shall be of stainless steel construction. The pump head and base shall be CI GG20 construction and impellers, diffusers, shaft sleeve, seal bush & pump shaft shall be in SS 304 material. The pump shall be provided with mechanical seal The system shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side (The pump should meet the condition and shall be gotten approved by the Local fire Authority). b. Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 HZ AC supply for the above pump with a synchronous speed of 2900 R.P.M. with flexible coupling and coupling guard etc. as required. c. Common base plate for (a) and (b) from M.S. channel as required size. d. Suitable cement concrete foundation with plaster, (design and drawing to be provided by the Contractor while the foundation will be done by others) complete with Antivibration arrangement of cushy foot mounting. For pump defined above & of duty as follows : Hydrant & Sprinkler System Flow : 180 LPM Head : 80 mts Supply, installation, testing and commissioning of jockey pump (pressurisation pump) comprising of the following:

1

-

95027.2

... More
Supplying, Installation, Testing and commissioning of electric driven terrace pump set on the terrace of the building suitable for automatic operation as per specification as required & comprising of following :- Horizontal mono-block centrifugal pump, suitable for operation on 415 volts ± 6%, 3 phase, 50 HZ A.C supply. The pump casing shall be CI, shaft shall be CS & impeller / shaft sleeve / casing wearing ring shall be bronze and with Mechanical seal. The system shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. (The pump should be tested for duty point test at factory and shall be approved by the Local Fire Authority). Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 HZ AC supply for the above pump with speed of 2900 R.P.M. Suitable cement concrete foundation with plaster, (design and drawing to be provided by the Contractor while the foundation will be done by others) complete with Antivibration arrangement of cushy foot mounting. Control Panels, wiring and other accessories shall also be included. For pump defined above & of duty as follows : Flow 900 LPM and Head 35 mtr.

1

-

95027.2

... More
Providing & fixing MS Class ‘C’ diesel engine exhaust pipe (including all fittings, clamps, steel support) of 100mm dia for the engine. The pipe shall be insulated with 100 mm thick mineral wool insulation wrapped in chicken mesh and clad with 24 gauge aluminium sheet.

15

-

2491.72

... More
Providing, fixing, testing and commissioning of precharged air vessel conforming to IS 2825 (size 450 mm dia & 2000 mm height cylinderical shell thickness not less than 6 mm and dish thickness not less than 8 mm) for pressurization of hydrant / sprinkler system complete with adequate pressure switches (as per design / requirement) with valves to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, 25 mm dia inlet with isolating valve duly painted from inside and outside complete as required.

1

-

15446.51

... More
Providing, fixing, testing & commissioning of Air release valve with 15mm dia stop cock, flanged inlet connection, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS IS : 12992 (Part 1).

1

-

3028.73

... More
Providing, fixing, testing & commissioning of dial type (100 mm) pressure gauge (glycerin filled) with isolation ball valve suitable for working pressure of 250 PSI with no Syphon. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required. (Range 0-16 kg/cm2)

5

-

984.34

... More
Supply, installation , testing & commissioning of male/ female screwed end full way lever operated forged brass ball valve(PN 16) of brass body with brass ball & teflon seat tested to a pressure 24 Kg / sqcm with (threaded joints) complete as required. (Cost shall be inclusive of providing necessary union / flange connection). 25 mm dia

5

-

1514.36

... More
Supply, Installation, Testing and commissioning of slim seal type C.I. Butterfly valve confirming to IS 13592 (Body : Grey Cast Iron, shaft : SS, Disc : SG Iron (Rilson coated), Liner : HT - EPDM) of approved make with PN 16 rating flange dimensions shall be confirming to IS 6392, washer, nuts & bolts. Rated to temperature of 85 Deg C and tested to a pressure not less than 24 Kg/Sq.cm. (a) 65 mm dia

1

-

2498.7

... More
(b) 80 mm dia

1

-

3028.73

... More
(c) 100 mm dia

2

-

4088.78

... More
(d) 150 mm dia

4

-

4861.11

... More
Providing, fixing, testing and commissioning of dual plate check valve (Body : Grey Cast Iron, Closure plate,bracket, hinge pin, washer, spring, set screw and plate : SS, seat : HT - EPDM) of pressure 16 Kg/sq.cm with flanges ( test pressure of 24 kg / sqcm), Nut,bolts & washers, painting etc. complete as required. (a) 65 mm dia

1

-

5527.43

... More
(b) 150 mm dia

2

-

10586.92

... More
Providing, fixing, testing and commissioning of spring loaded relief valve suitable for pressure of 16 Kg / sq.cm with Body, cover of cast steel, stem-stainless steel 304, seat and seal -EPDM, Body seat ring , nuts and bolts of stainless steel and including gasket, gland packing, flanges conforming to IS 6392(PN 16) etc all as required to complete the system. 25 mm dia

5

-

2498.7

... More
Providing, fixing, testing and commissioning of CI `Y' strainer for pressure of 16 kg / sq.cm with bronze perforated sheet basket including rubber gasket, flanges ( test pressure of 24 kg / sqcm), nuts, bolts and washers, panting of the same complete as required and suitable for system pressure. (a) 80 mm dia

1

-

8480.44

... More
(b) 200 mm dia

2

-

15398.05

... More
Providing, fixing, testing and commissioning of Vortex inhibitors at suction line from fire tank to prevent Air entrapment and its resultant choking effect on full flow discharge and eliminating potential damage to booster pump equipment by preventing initiation of vortices within a tank when the contained liquid is being extracted and assists in maximizing effective tank capacity. the vortex plate shall be constructed of SS 316 coupled on MS pipe of thickness not less than 6 mm. the item includes painting, bends, etc all as required.

4

-

6587.48

... More
Providing & fixing of CI /forged brass body gate valves confirming to IS:778 class II with high tensile brass rising stem suitable for the system pressure 16 kg/ cm2 including & fitting etc complete as required. (a)80 mm dia

1

-

10577.83

... More
(b) 200 mm dia

2

-

18500

... More
Providing & fixing heavy duty double flanged flexicon rubber expansion joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required. (a) 65 mm dia

1

-

3483.04

... More
(b) 80 mm dia

1

-

4315.94

... More
(d) 150 mm dia

2

-

6500

... More
(e) 200 mm dia

2

-

8329

... More
Providing & fixing Sluice valve (double flanged) of CI body and brass non-rising type sprindle for PN 1.6 rating, conforming to IS:14846 complete in all respects. 200 mm dia

2

-

28015.73

... More
Providing, fixing, testing and commissioning of heavy class MS suction & delivery headers of required length conforming to IS:3589 with welded joints standard MS Fittings and with end flange connections having inlet & outlet flanged connections and painting of two coats of synthetic enamel paint over two coats of primer as per specification including GI supports from wall, floors & ceiling complete as required. Cost should be inclusive of all supports/clamps / brackets, anchor fastner, expansion bellows etc. as required (all in GI). MS `C' Heavy class pipe (a) 25 mm dia

15

-

345.91

... More
(b) 32 mm dia

5

-

402.01

... More
(c) 40 mm dia

5

-

442.08

... More
(d) 50 mm dia

8

-

580.32

... More
(e) 65 mm dia

10

-

1041.13

... More
(f) 80 mm dia

5

-

1185.39

... More
(g) 100 mm dia

5

-

1233.47

... More
(h) 150 mm dia

35

-

1670.72

... More
(i) 200 mm dia

25

-

2147.11

... More
(j) 250 mm dia

25

-

2507.75

... More
Providing, fixing, testing and commissioning of Installation Control Valve with turbine type automatic Alarm Gong to be connected with control valve, drain & test valve and all other necessary components as per manufacturer's specifications complete as required. 150 mm dia

1

-

94950.6

... More
INTERNAL HYDRANT Providing, laying, jointing, testing and commissioning of following sizes of pipes conforming to IS-1239 with all accessories like all fittings (standard MS fitting with welded joint shall be used on the pipes) including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor / wall /ceiling with clamps, hangers (using anchor fastners) and painting of two coats of synthetic enamel paint over two coats of primer as per specification. G.I. pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls/floors and sealing the sleeves with glass wool in between & fire sealent compound at either end all as per Project Manager’s / Consultants requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets etc. shall be of galvanized iron unless specified otherwire and then supply of the same shall also be included for rates under this head. For wet riser System - MS `C' Heavy class pipe (a) 25 mm dia

101

-

345.91

... More
(b) 65 mm dia

26

-

1041.13

... More
(c) 80 mm dia

167

-

1185.39

... More
(d) 100 mm dia

355

-

1233.47

... More
(e) 150 mm dia

880

-

1670.72

... More
Providing & fixing male/ female screwed end full way lever operated forged brass ball valve(PN 16) of brass body with forged brass hard chrome plated steel ball & teflon seat tested to a pressure 24 Kg / sqcm with (threaded joints) complete as required with nuts, bolts, gaskets, washers etc.. 25 mm dia

50

-

1514.36

... More
Providing & fixing butterfly valve conforming to IS 13095 PN 16 (Body : Grey Cast Iron, Shaft : SS, Disc : SS, Liner : HT - EPDM) (upto 150mm dia with hand lever operation & above with gear box operation). Including rubber gasket, flanges nuts, bolts, washers & painting complete as required as per specification.(suitable for test pressure of 24 kg / sqcm) (a) 100 mm dia

50

-

4089

... More
(b) 150 mm dia

14

-

4861.11

... More
Providing, fixing, testing and commissioning of dual plate check valve (Body : Grey Cast Iron, Closure plate,bracket, hinge pin, washer, spring, set screw and plate : SS, seat : HT - EPDM) of pressure 16 Kg/sq.cm with flanges ( test pressure of 24 kg / sqcm), Nut,bolts & washers, painting etc. complete as required. 150 mm dia

2

-

8480.44

... More
Providing, fixing, testing and commissioning of CI `Y' strainer for pressure of 16 kg / sq.cm with bronze perforated sheet basket including rubber gasket, flanges ( test pressure of 24 kg / sqcm), nuts, bolts and washers, panting of the same complete as required and suitable for system pressure. 150 mm dia

2

-

12039.19

... More
Providing, fixing, testing and commissioning of Gun metal fire hydrant single landing valve with 80 NB flanged inlet, brass spindle controlled 63 mm dia female instantaneous outlet type. G.M coupling, blank cap, chain, twist release type lug & all accessories. Conforming to IS:5290. Including fixing with anchor fastner and flanged tapping from wet riser and providing pressure gauge with ball valve with all accessories, nuts, bolts, gaskets, painting complete as required.

44

-

6360.33

... More
Providing, fixing, testing & commissioning of swinging type First Aid hose reel in red colour drum ( LPCB approved) with 36.5 mts. long and 20 mm dia heavy duty rubber water hose, 20 mm dia Ball valve stop cock, terminating with G.M coupling & nozzle of 6mm outlet with shut off valve confirming to IS 8090 - 1976 complete with MS socket for tap-off, drum and brackets (including painting) for fixing on wall with anchor fastner, bolts & nuts conforming to IS:884-1969 complete as required.

44

-

11963.47

... More
Providing, fixing, testing & commissioning of Perlocating, hose pipe (as per IS : 8423) of 63 mm dia and length as described below. The hose shall be rated for brust pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked brass male & female coupling (IS:903) bound & rivetted to hose pipe with copper rivets & 1.5 mm copper wire. (Internal fire hydrant)

88

-

4543.09

... More
Providing, fixing, testing & commissioning of 63 mm dia instantaneous pattern branch short Gun metal pipe, 19 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required.

44

-

2120.11

... More
Providing, fixing, testing & commissioning of standard firemans axe with heavy rubber handle.

44

-

984.34

... More
Providing, fixing, testing & commissioning of dial type (100 mm) pressure gauge with isolation ball valve suitable for rating 0 to 250 PSI with no Syphon. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required.

44

-

984.34

... More
Providing, fixing, testing & commissioning of Fire Cabinet fabricated from 40 x 40 x 5 angle iron sections and 14 gauge MS sheet with full front glass door, suitable to accommodate landing valves, 15 m long hoses, first-aid hose reel and branch pipe nozzle, fire extingui & fire mans’ axe. The shutter shall be painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade, as required (Approx 2.1 m (high) x 0.9 m (wide)x 0.6m (deep). (Cost shall be inclusive of providing break glass box containing key for the cabinet along with hamer).

44

-

15007.34

... More
Providing, fixing, testing & commissioning of MS air cushion tank on top of each riser fabricated from 6mm thick MS plate, 200 mm in diameter and 1.2 m in height with dished ends fabricated from 6 mm thick MS plate with Air release valve & stop cock, flanged inlet connection with all accessories as required and conforming to IS 4736-1968. (The cushion tank should be suitable for rated working pressure.

6

-

16506.56

... More
Providing, fixing, testing & commissioning of automatic Air release valve with 15mm dia stop cock, flanged inlet connection, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS IS : 12992 (Part 1).

6

-

1226.63

... More
SPRINKLER SYSTEM Providing, laying, jointing, testing and commissioning of following sizes of pipes conforming to IS-1239 with all accessories like all fittings (for pipes upto 50mm dia threaded forged steel fittings and for pipes above 50 mm dia MS fitting with welded joint shall be used) including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, hangers (using anchor fastners) as per specification. Providing two coats of synthetic enamel paint of approved shade over two coats of primer. Prior to application of primer the surface should be cleaned for any dirt, rusts, rough substance etc. Including painting of legends both direction arrow as per the approval of the Project Manager. GIpipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & fire sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects.

-

-

-

... More
All hangers, clamps, brackets etc. shall be of galvanized iron unless specified otherwise and the supply of the same shall also be included in rates under this head. Welding of any kind on the galvanized support / hanger shall not be permitted. For Sprinkler system - MS `C' Heavy class pipe (a) 25 mm dia

1485

-

345.91

... More
(b) 32 mm dia

297

-

402.01

... More
(c) 40 mm dia

275

-

442.08

... More
(d) 50 mm dia

416

-

580.32

... More
(e) 65 mm dia

178

-

1041.13

... More
(f) 80 mm dia

475

-

1185.39

... More
(g) 100 mm dia

297

-

1233.47

... More
(h) 150 mm dia

385

-

1670.72

... More
Providing & fixing male/ female screwed end full way lever operated forged brass ball valve(PN 16) of brass body with forged brass hard chrome plated steel ball & teflon seat tested to a pressure 24 Kg / sqcm with (threaded joints) complete as required with nuts, bolts, gaskets, washers etc.. 25 mm dia

11

-

1514.36

... More
Providing & fixing butterfly valve conforming to IS 13095 PN 16 (Body : Grey Cast Iron, Shaft : SS, Disc : SS, Liner : HT - EPDM) (upto 150mm dia with hand lever operation & above with gear box operation). Including rubber gasket, flanges nuts, bolts, washers & painting complete as required as per specification.(suitable for test pressure of 24 kg / sqcm) (a) 65 mm dia

2

-

2498.7

... More
(b) 80 mm dia

1

-

3028.73

... More
(c) 100 mm dia

6

-

4088.78

... More
(d) 150 mm dia

3

-

4861.11

... More
Providing, fixing, testing & commissioning of brass quartzoid sprinklers (UL approved) of 15 mm dia size, suitable for sustaining the pressure on the seat & water hammer effect. The type & temperature rating shall be as follows : (a) Spray recessed (adjustable) rossette (68 deg.C) sprinkler quick response pendant

39

-

252.09

... More
(b) Spray recessed (adjustable) rossette (68 deg.C) sprinkler quick response upright type

550

-

252.09

... More
(c) Sidewell extended coverage (68 °C) sprinkler quick response type.

44

-

265.01

... More
(d) Spray recessed (adjustable) rossette (141 deg.C) sprinkler quick response pendant

6

-

560.31

... More
Providing & fixing water curtain nozzle in Brass (ASTM B'16) suitable for 20 to 100 psi effective working pressure, with 1/2" BSPT inlet, K-23 and coverage of 2.5 meter either side at 1.4 Bar

11

-

318.02

... More
Providing and fixing solenoid valve including power and control wiring upto panel & ON/OFF arrangement and all other associated works of complete as required.

3

-

15067.92

... More
Providing, fixing, testing & commissioning of inspectors test assembly complete with test valve, sight glass sectional drain valve, union with corrosion resistant orifice all complete strictly as per drawing. 50 mm dia

2

-

5527.43

... More
Providing and fixing of corrugated stainless steel (AISI 304) unbraided flexible sprinkler pipe drops of 25 mm dia of following length and maximum working pressure of 175 psi with all accessories and clamps as required. The flexible pipe drop shall be UL approved. The pipe drop shall be of following sizes: 1.2 M length

35

-

2498.7

... More
Providing, fixing, testing & commissioning of dial type (100 mm) pressure gauge gyclerin filled with isolation ball valve suitable for working pressure of 250 PSI with no Syphon. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required.

6

-

984.34

... More
Supply, installation, testing and commissioning of electrically operated water flow switches (Vane type) including all accessories, complete required.

2

-

6451.19

... More
FIRE EXTINGUISHERS (ACADEMIC BLOCK)

-

-

-

... More
Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner). Providing & fixing ISI marked portable chemical fire extinguisher, water (gas pressure) type capacity 9 litres conforming to IS: 15683 : 2006 with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets.

38

-

4543.09

... More
Providing & fixing ISI marked (IS: 15683 : 2006) portable CO2 type fire extinguisher type 4.5 kg capacity. Including valve, discharge hose of not less than 10 mm dia & 1 M long complete in all respects including initial filled with CO2 gas confirming to IS:307-1966 & filled to a filling rate of not more than 0.667 and wall suspension bracket.

38

-

5527.43

... More
Providing & fixing of ABC Type, Portable Fire Extinguisher, dry powder type (Gas Cartridge) conforming to IS: 15683 : 2006 with cylinder initially fully charged with dry powder, ISI marked confirming to IS:15683 : 2006 complete with standard discharge valve with tube, CI bracket for wall mounting. (a) 4.5 Kg

38

-

4543.09

... More
(b) 9 Kg

13

-

6636.11

... More
Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked / approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and conforming to IS:910 (a) 9 Litres

13

-

8480.44

... More
(b) 50 Litres (trolley mounted)

2

-

21958.27

... More
Supplying and installing at approved location approved make fire buckets (6 No.) of 24 gauge galvanized steel sheet confoming to IS: 2546, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer.

38

-

3028.73

... More
EXTERNAL FIRE HYDRANT SYSTEM. (ACADEMIC BLOCK)

-

-

-

... More
Providing, laying, jointing, testing and commissioning of following sizes of pipes with all accessories like all fittings (for pipes upto 50mm dia threaded forged steel fittings and for pipes above 50 mm dia MS fitting with welded joint shall be used) including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor/wall/ceiling with clamps, hangers (using anchor fastners) as per specification. Providing two coats of synthetic enamel paint of approved shade over two coats of primer. Prior to application of primer the surface should be cleaned for any dirt, rusts, rough substance etc. Including painting of legends both direction arrow as per the approval of the Project Manager. GIpipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls / floors and sealing the sleeves with glass wool in between & fire sealent compound at either end all as per Project Manager’s requirements including cutting holes and chases in brick, RCC work and making good the same to original conditions complete in all respects. All hangers, clamps, brackets etc. shall be of galvanized iron unless specified otherwise and the supply of the same shall also be included in rates under this head. Welding of any kind on the galvanized support / hanger shall not be permitted. Wherever the pipes running below ground shall not be less than 1.0 m below ground level at any point. Pipes shall embedded all round 150 mm thick compacted silver sand and protection to GI pipes and fitting by applying pypkote primer @ 100 gm/sqm). Thereafter wrapping 4 mm thick pypkote (AW4mm) protection coating by thermo fusion process. Overlap shall be maintained at 20 mm. The application shall be strictly as per manufacturers’ specifications. (a)80 mm dia nominal bore

100

-

1185.39

... More
(b) 150 mm dia nominal bore

350

-

1670.72

... More
Providing and fixing of SS fire brigade 4-way connection (suction collecting head) consisting of 4 No. 63 mm dia instantaneous type male couplings with built-in swing check valves, 1 No. 150 mm dia Butterfly valve, 1 No. 150 mm dia non-return valve and 150 mm dia flanged outlet complete with bolts, nuts and rubber insertions as required .

2

-

15900.82

... More
Providing & fixing MS cabinet (to enclose above FB connection) fabricated from 16g MS sheet with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of stove enamel paint of approved make and shade and suitably mounted on a raised masonry platform as required (Approx 0.6m x 0.6m x 0.45m)

2

-

8480.44

... More
Providing and fixing of SS fire brigade suction hose coupling (draw-out connection) with nut for female coupling complete with 100 mm dia GI suction pipe and 100 mm dia foot valve (to be connected to static tank). Provision of GI drop pipe and foot valve shall be made in all the fire water static storage tanks (4 No) (GI pipe to be paid separately through appropriate item while cost of foot valve to be included).

1

-

8480.44

... More
Providing & fixing MS cabinet (to enclose fire brigade suction collecting head and draw-out connection as per Item above) fabricated from 16 g MS sheet with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of stove enamel paint of approved make and shade and suitably mounted on a raised masonry paltform as required (Approx 0.6 m x 0.6 m x 0.45 m)

1

-

8480.44

... More
Providing & fixing male/ female screwed end full way lever operated forged brass ball valve(PN 16) of brass body with forged brass hard chrome plated steel ball & teflon seat tested to a pressure 24 Kg / sqcm with (threaded joints) complete as required with nuts, bolts, gaskets, washers etc.. 25 mm dia

10

-

1514.36

... More
Providing & fixing butterfly valve PN 16 (Body : Grey Cast Iron, Shaft : SS, Disc : SS, Liner : HT - EPDM) (upto 150mm dia with hand lever operation & above with gear box operation). Including rubber gasket, flanges nuts, bolts, washers & painting complete as required as per specification.(suitable for test pressure of 24 kg / sqcm) (a) 80 mm dia

10

-

3028.73

... More
(b) 150 mm dia

5

-

4861.11

... More
Providing and fixing of Gun metal fire hydrant single landing valve with 80 NB flanged inlet, brass spindle controlled 63 mm dia female instantaneous outlet type. G.M coupling, blank cap, chain, twist release type lug & all accessories. Including fixing with anchor fastner and flanged tapping from wet riser and providing pressure gauge with ball valve with all accessories, nuts, bolts, gaskets, painting complete as required.

10

-

6360.33

... More
Providing, fixing, testing & commissioning of non-perlocating, rubber reinforced lined fire hose pipe of 63 mm dia and length as described below. The hose shall be rated for brust pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked brass male & female coupling bound & rivetted to hose pipe with copper rivets & 1.5 mm copper wire. (External fire hydrant) 15 m length

20

-

4543.09

... More
Providing and fixing of 63 mm dia instantaneous pattern Gun metal branch pipe, 20 mm dia nozzle , suitable for inter connection to hose pipe coupling complete as required.

10

-

2120.11

... More
Providing and fixing of dial type (150 mm) pressure gauge glycerin filled with isolation ball valve suitable for working pressure of 250 PSI with no Syphon. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required.

10

-

984.34

... More
Providing and fixing weather proof lockable cabinet of size not less than 0.9 x 0.6 x 0.45 mtr made out of MS sheet of 16 gauge thickness having central opening and 4 mm thick glazed glass doors (Two No.) suitably marked on the outside with the letters "FIRE HOSE" including necessary locking arrangement and shall be painted with one coat of primer and two coats of stove enamel paint of approved shade. (The aesthetics and design of the cabinet shall be as per the architect / Client). (Cost shall be inclusive of providing break glass box containing key for the cabinet along with hamer).

10

-

14992.2

... More
Supply , installation , testing and commissioning of Seamless Cylinder CCOE approved suitable to hold 140 Kgs of Novec Novec at 50/42 BAR , complete with valve assembly and arrangement for supervisory switch connection for monitoring cylinder pressure , a pressure gauge (Main) -1no. Supply, installation ,testing and commissioning of NOVEC 1230 AGENT PER 1KG. -1no. Supply , installation , testing and commissioning of Electric control head operated electrically from the Detection & control system or locally with a manually level on the control head . Supply , installation , testing and commissioning of pressure operated Control Head. Supply , installation , testing & commissioning of Master Cylinder Adapter kit used to actuate the Slave cylinder -1no. Supply , installation , testing & commissioning of Flexible discharge Hose route the Novec Agent from the storage cylinders to the discharge piping by a 2" flexible rubber hose with wire braided reinforcements. This hose is connected to the discharge out -1no. Supply, installation , testing & commissioning of Manifold Check Valve installed at the dsicharge manifold to allow removal of any Novec cylinder from the manifold while still remaining a closed system Supply , installation , testing and commissioning of MS Container Strap Supply, installation , testing & commissioning of Flexible Actuation Hose (Pilot pressure is directed to a pressure operated control head on each cylinder valve using 1/4 inch actuation hose) -1no.

-

-

-

... More
Supply, installation , testing & commissioning of Switch, Pressure, DPST, Weather Proof (2 - 3/4 in. Outlets), Latching -1no. Supply, installation , testing & commissioning of Warning Plate for Use Inside Room -1no. Supply, installation , testing & commissioning of Warning Plate for Use Outside Room Supply, installation , testing & commissioning of Manifold fabricated from seamless pipes Sch 80 for 2 Cylinder -1no. Supply , installation , testing & commissioning of Piping with ASTM Sch 40 -1no. Supply , installation , testing & commissioning of Novec gas discharge nozzle -2no. NOZZLE 42/50 BR Supply, installation, testing & commissioning of Photo thermal multicriteria intelligent addressable detector with standard base etc.complete as required and as per specifications.-2no. Supply ,installation, testing & Commissioning of Gas release module (UL listed) of the same make as Fire Detection system complete as required. -1no. Supply ,installation, testing & Commissioning complete set fo gas supression -1no.

1

-

1191100

... More
ELECTRICAL WORKS

-

-

-

... More
Design, Fabrication,Supply, Installation, Testing and Commissioning of following Wall mounted / Floor mounted(including base stand), 415V,3PH, 50Hz extensible and fully compartmentalized panels complying to IS 8623/93. The indoor panels shall be IP 42 and outdoor panels shall be IP 54 type.The Panel shall have proper space with required clearance for cables, incoming / outgoing switchgear, CTs, PTs, ammeter, Voltmeter, selector switches, Insulated and properly supported compartmentalized bus bars with heat shrinkable sleeves along with the other control circuit accessories within the panel and any other electrical component mentioned in the Panel SLD.The panel shall be fabricated out of CRCA not less than 2.0 mm thick for load bearing members and 1.6mm for the doors of LT panel.The Panel shall have seven tank pre treatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having a paint thickness of 60 microns or as specified.The Panel shall be Dust/Vermin poof with earth studs as per the SLD and specifications Incoming compartment consisting of : a) R,Y,B indication lamp with 2A control MCB b) 1 Nos. x 400 A, Four pole , MCCB, 25kA, Microprocessor based with E/F release and TNC switch for breaker operation. d) R,G,A indication lamps for On, Off and trip indication of main incomer. e) Digital ammeter 0-400A with inbuilt selector switches and its associated 3 x 400/5A, 15VA,CT f) Digital voltmeter 0-500V with inbuilt selector switches.

-

-

-

... More
Bus bar : 500 Amp, 25kA, FP Al busbar. Outgoing compartment consisting of : a) R,Y,B indication lamp with 2A control MCB b) Digital voltmeter 0-500V with inbuilt selector switches. c) Star-delta starters suitable for motors of plumbing pumps of below mentioned capacities. The starter shall comprise of all necessary power and control equipments including Star contactor , delta contactor , timer relay contactor, electronic timer, potential free NO/NC contacts and necessary control wirings properly connected in fully usable state. Minimum utilization catagory for all contactors shall be AC3 and contactor shall be capable to withstand the steady state (full load) and starting inrush current. The starter shall have necessary protection device (MPCB + EOCR) whose settings and ratings shall be as per the type-2 co-ordination chart. The starter shall have inbuilt protection against overcurrent, short circuit and single phasing. All these starters shall be equipped with discharge resistors suitable for making the starter run under the closed transition state. All below mentioned starters shall be housed inside the panel compartment and shall be provided with 2NO+2NC contacts additionally. 75hp star delta starter (2No.) , 100A , FP MCCB with OLR range 45-63A, 115A delta contactor ,65A star contactor and 0-250A digital ammeter with inbuilt selector switch and 3Nos. 250/5A, 15VA CT 7.5hp star delta starter (2No.) , 16A FP MPCB with OLR range 5-8A, 16A delta contactor,9A star contactor and 0-40A digital ammeter with inbuilt selector switch. 7.5hp star delta starter (2No.) , 16A FP MPCB with OLR range 5-8A, 16A delta contactor,9A star contactor and 0-40A digital ammeter with inbuilt selector switch.

1

-

550000

... More
Supply, Installation, Testing and Commissioning of following armoured cables from plumbing panel to sub feeder. All the below mentioned cables shall be 1.1kV grade, XLPE insulated, FRLS type armoured cables of Al / Cu, whichever applicable with inner and outer PVC sheath.The said cables shall confirm IS 7098-1, BS 5467, IEC 60502-1, BS 7889 all supplymentary.The rate shall include complete Supply, Installation, testing and commissioning rates including cost of all tools and accessories required to Complete the job in full respect. Power Cables (a) 3.5C x 240 SQMM A2XFY

30

-

1631

... More
(b) 4C x 16 SQMM 2XWY

40

-

976

... More
(c) 2C x 2.5 SQMM Cu. Control cable

70

-

157

... More
(d) 4C x 2.5 SQMM Cu. Control cable

50

-

330

... More
(e) 6C x 2.5 SQMM Cu. Control cable

20

-

486

... More
(f) 8C x 2.5 SQMM Cu. Control cable

20

-

600

... More
Supply, Installation, Testing and Commissioning of end terminations of following armoured cables. All the lugs shall be of cu lugs and glands shall be double compression brass glands as per the technical specifications. The cost shall include the cost of crimping and all tools and accessoriesd required to complete the job in full respect. Power Cables (a) 3.5C x 240 SQMM A2XFY

8

-

1075

... More
(b) 4C x 16 SQMM 2XWY

8

-

976

... More
(c) 2C x 2.5 SQMM Cu. Control cable

24

-

40

... More
(d) 4C x 2.5 SQMM Cu. Control cable

16

-

78

... More
(e) 6C x 2.5 SQMM Cu. Control cable

4

-

125

... More
(f) 8C x 2.5 SQMM Cu. Control cable

4

-

156

... More
CABLES TRAYS Supply and fixing of factory fabricated GI perforated / Ladder type hot dip galvanised cable trays, with radial bends, suspenders and supports as per specification and of the following sizes. 450 mm width X 50 mm depth X 1.6 mm thickness (Ladder)

60

-

980

... More
100 mm width X 50 mm depth X 1.6 mm thickness (Perforated)

30

-

280

... More
150 mm width X 50 mm depth X 1.6 mm thickness (Perforated)

30

-

357

... More
300 mm width X 50 mm depth X 1.6 mm thickness (Perforated)

30

-

598

... More
EARTHING CONDUCTORS

-

-

-

... More
8 SWG GI Strip

10

-

26

... More
25 x 6 GI Strip

160

-

131

... More
DG SET

-

-

-

... More
Supplying, installation, testing and commissioning of 250 kVA silent type DG set (with acoustic canopy) complete with following accessories Supplying, installation, testing and commissioning of 4 stroke Diesel engine of suitable BHP at 1500 rpm suitable for 250 kVA output of the alternator at site condition, capable of taking 10% overloading for one hour in any 12 hrs of running without loosing its rpm complete with Dynamically balanced flywheel,Flexible coupling,Exhaust gas turbo charged with Cooling System , Automatic safety control in case of low lubrication oil pressure, Automatic safety control in case of high water temperature. Automatic overspeed trip protection. The engine shall have Lubrication oil pump.Lubrication oil filter.Lubrication oil cooler.Bye-pass filter,Fuel pump,Fuel Filter,Hoses for fuel tank.Air intake manifold.Air cleaner dry type. Governor EFC type.Selfstarter.Alternator for battery charging.Residential silencer. Flexible pipe for silencer. Batteries for excitation with Battery charger.Techometer with hour meter,Auto mains failure controller, Engine control panel as applicable & as per manufacturers standard . Supplying, installation, testing and commissioning of synchronous alternator rated 250 KVA at 1500 rpm, 3 phase ,50Hz AC supply with 0.8 pf (lagging) at site condition.The alternator shall have SPDP enclosure (IP-23), brushless contineous duty, self excited and self regulated suitable for the environmental conditions and with H class of insulation.The alternator shall be fitted with thermistors (controlled by AMC controller) for winding and bearing temperature and space heaters, AVR , battery charger for self excitation etc. complete in all respects.The alternator shall be fitted with suitable arrangement to bring out bus duct of required sizes as mentioned in the SLD, along with CT for restricted earth fault protection and droop compensation .The rate shall include complete supplying, installation, testing and commissioning rates including cost of all tools and accessories (as mentioned below and

1

-

2325000

... More
DG SET (MARRIED ACCOMODATION)

-

-

-

... More
Supplying, installation, testing and commissioning of 82.5 kVA silent type DG set (with acoustic canopy) complete with following accessories "Supplying, installation, testing and commissioning of 4 stroke Diesel engine of suitable BHP at 1500 rpm suitable for 82.5 kVA output of the alternator at site condition, capable of taking 10% overloading for one hour in any 12 hrs of running without loosing its rpm complete with Dynamically balanced flywheel,Flexible coupling,Exhaust gas turbo charged with Cooling System , Automatic safety control in case of low lubrication oil pressure, Automatic safety control in case of high water temperature. Automatic overspeed trip protection. The engine shall have Lubrication oil pump.Lubrication oil filter.Lubrication oil cooler.Bye-pass filter,Fuel pump,Fuel Filter,Hoses for fuel tank.Air intake manifold.Air cleaner dry type. Governor EFC type.Selfstarter.Alternator for battery charging.Residential silencer. Flexible pipe for silencer. Batteries for excitation with Battery charger.Techometer with hour meter,Auto mains failure controller, Engine control panel as applicable & as per manufacturers standard . " Supplying, installation, testing and commissioning of synchronous alternator rated 82.5 KVA at 1500 rpm, 3 phase ,50Hz AC supply with 0.8 pf (lagging) at site condition.The alternator shall have SPDP enclosure (IP-23), brushless contineous duty, self excited and self regulated suitable for the environmental conditions and with H class of insulation.The alternator shall be fitted with thermistors (controlled by AMC controller) for winding and bearing temperature and space heaters, AVR , battery charger for self excitation etc. complete in all respects.The alternator shall be fitted with suitable arrangement to bring out bus duct of required sizes as mentioned in the SLD, along with CT for restricted earth fault protection and droop compensation .The rate shall include complete supplying, installation, testing and commissioning rates including cost of all tools and accessories (as mentioned below and any other required) required to Complete the job in full respect.

1

-

660000

... More
Academic Block

-

-

-

... More
Main Isolation Panel Main Isolation Panel "Incoming from 630KVA Transformer- 2 nos.: 2 x 1000 A, FP, 50 kA, Electrically draw out type ACB with On, Off, Trip, Spring Charge indication and with inbuilt LSIG protection with microprocessor based release, shunt release (24V DC), inbuilt O/C & SC releases (Microprocessor based) having variable range with time lag facility to acheive discrimination. And required Interlocking with other incomer & Bus Coupler to be provided as per Interlocking / operation scheme indicated in Single Line diagram. The ACB shall have suitable arrangement for termination of cable on incoming side and busbar connection at outgoing side as per single line diagram, complete with following for each incomer:" "2 x 50kA, 2kVp surge arrester with suitable Fuse. 2 x R,Y,B,On,Off,Trip,Spring charge, Service position, test position, ready to close, trip circuit healthy LED indication lamp with 2A control MCB etc. as required. 2 x (16 window annunciation panel with trip, accept & reset options along with hooter) 2 x (4 nos. 1000/1A, CL-PS, 15VA, ring type CT for restricted earth fault relay) 2 x (emergency Push buttons, auto/manual switch, etc. as required) 2 x (3 nos. 1000/5A, CL-1, 15VA, ring type CT for 240V actuated numeric type APFC relay) 2 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of THD, KVARH KW, KWH, KVAR, PF, V, A, Hz with 15VA Class 1.0 CTs of required ratio)"

-

-

-

... More
Including providing, installation, testing and commissioning of Micro PLC for Auto Load Management as per Logic mentioned in Single Line Diagram, comprising required Auxiliary relays (24V DC, indication lights, Push button, Emergency stop, A/M position switch, Battery charger (230V A/C / 24V DC), Batteries, Digital I/O card, analogue card, 24V DC power supply as required. "Busbar : 3000A, 415V, FP, 36 kA/1sec, Electrolytic high conductivity Aluminium busbar insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints." "Buscoupler : 1 x 2500 A, FP, 50 kA, EDO type ACB with On, Off, Trip, Spring Charge indication and with inbuilt LSIG protection with microprocessor based release. Required Interlocking with other incomer & Bus Coupler to be provided as per Interlocking / operation scheme indicated in Single Line diagram." "Incoming from DG Sync. Panel-02 nos.: 2 x 2500 A, FP, 50 kA, Electrically draw out type ACB with On, Off, Trip, Spring Charge indication and with inbuilt LSIG protection with microprocessor based release, shunt release (24V DC), inbuilt O/C & SC releases (Microprocessor based) having variable range with time lag facility to acheive discrimination. And required Interlocking with other incomer & Bus Coupler to be provided as per Interlocking / operation scheme indicated in Single Line diagram. The ACB shall have suitable

-

-

-

... More
2 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 630/5A, 10VA Class 1.0 CTs)" "2 x 400 A, FP, 36kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with micoprocessor based release. 1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 400/5A, 10VA Class 1.0 CTs)" "4 x 200 A, FP, 36kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release. 2 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 200/5A, 10VA Class 1.0 CTs)" "6 x 100 A, FP, 36kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release. 3 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 100/5A, 10VA Class 1.0 CTs)"

1

-

2250000

... More
Main Fire Panel Incomer 1 x R,Y,B LED indication lamp with 2A control MCB 1 x 400A 4P Auto source transfer switch with complete neutral overlap suitable for cable on incoming & bus bar connection on outgoing side and to be connected as shown in SLD. 1 x 400 A, FP, 36kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release. 1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of PF, V, A, Hz with 3X400/5A, 5VA Class 1.0 CTs) Busbar : 500A, 415V, FP, 25 kA/1sec, Aluminium busbar. Outgoings : 1 x 200 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with thermal magnetic release. 5 x 100 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with thermal magnetic release. 4 x 63 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with thermal magnetic release.

1

-

750000

... More
Ventilation Panel Incomer: 1 x R,Y,B LED indication lamp with 2A control MCB 1 x 100 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with thermal magnetic based release. 1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 3X100/5A, 5VA Class 1.0 CTs) Busbar : 150A, 415V, FP, 16 kA/1sec, Aluminium busbar. Outgoings : 4 x 63 A, FP, 10kA, MCB "C Curve". 4 x 40 A, FP, 10kA, MCB "C Curve". 4 x 63 A, DP, 10kA, MCB "C Curve". 4 x 40 A, DP, 10kA, MCB "C Curve".

3

-

280000

... More
Terrace Panel Incomer: 1 x R,Y,B LED indication lamp with 2A control MCB 1 x 400 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release. 1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KVAR, PF, KWH, V, A with 3X400/5A, 5VA Class 1.0 CTs) Busbar : 500A, 415V, FP, 16 kA/1sec, Aluminium busbar. Outgoings : 2 x 100 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with thermal magnetic release. 6 x 63 A, FP, 10kA, MCB "C Curve". 6 x 40 A, FP, 10kA, MCB "C Curve".

2

-

350000

... More
UPS Input Panel (3X60KVA UPS) Incomer/Outgoing: 3 x R,Y,B LED indication lamp with 2A control MCB 3x 125 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release. 3 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, V, A with 3X100./5A, 5VA Class 1.0 CTs)

1

-

210000

... More
UPS Output Panel (3X30KVA UPS) Incomer/Outgoing: 3 x R,Y,B LED indication lamp with 2A control MCB 3 x 125 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release. Busbar : 450A, 415V, FP, 10 kA/1sec, tinned copper busbar. Outgoings : 10x63A, FP, 10kA, MCCB "D Curve" 8 x 40 A, FP, 10kA, MCB "D Curve". 6x 32 A, FP, 10kA, MCB "D Curve". 6 x 40 A, DP, 10kA, MCB "D Curve".

1

-

190000

... More
UPS Input Panel (2X30KVA UPS) Incomer/Outgoing: 2 x R,Y,B LED indication lamp with 2A control MCB 2 x 100 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release. 2 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, V, A with 3X100./5A, 5VA Class 1.0 CTs)

1

-

180000

... More
UPS Output Panel (3X30KVA UPS) Incomer/Outgoing: 2 x R,Y,B LED indication lamp with 2A control MCB 2 x 100 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release. Busbar : 250A, 415V, FP, 10 kA/1sec, tinned copper busbar. Outgoings : 8 x 63 A, FP, 10kA, MCB "D Curve". 8 x 40 A, FP, 10kA, MCB "D Curve". 6 x 32 A, DP, 10kA, MCB "D Curve".

1

-

175000

... More
Manual source transfer switch suitable for on-load and off-load transitions of following ratings in an IP55 rated 2mm thick powder coated MS enclosure with provision for termination of cable on incoming and outgoing side as shown in SLD. (a) 100A FP 25KA

27

-

15000

... More
(b) 125A FP 25KA

3

-

20000

... More
(c) 400A FP 25KA

2

-

30000

... More
Main Isolation Panel "Incoming from 315KVA Transformer- 1 nos.: 1 x 630 A, FP, 36 kA, MCCB with On, Off, Trip indication and with inbuilt LSIG protection with microprocessor based release. And required Interlocking with other incomer & Bus Coupler to be provided as per Interlocking / operation scheme indicated in Single Line diagram. The MCCB shall have suitable arrangement for termination of cable on incoming side and busbar connection at outgoing side as per single line diagram, complete with following for each incomer:" "1 x 50kA, 2kVp surge arrester with suitable Fuse. 1 x R,Y,B,On,Off,Trip,Spring charge, Service position, test position, ready to close, trip circuit healthy LED indication lamp with 2A control MCB etc. as required. 1 x (16 window annunciation panel with trip, accept & reset options along with hooter) 1 x (4 nos. 630/1A, CL-PS, 15VA, ring type CT for restricted earth fault relay) 1 x (emergency Push buttons, auto/manual switch, etc. as required) 1 x (3 nos. 630/5A, CL-1, 15VA, ring type CT for 240V actuated numeric type APFC relay) 1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of THD, KVARH KW, KWH, KVAR, PF, V, A, Hz with 15VA Class 1.0 CTs of required ratio)"

-

-

-

... More
"Incoming from 250KVA DG Set - 2 nos.: 1 x 400 A, FP, 36 kA, MCCB with On, Off, Trip indication and with inbuilt LSIG protection with microprocessor based release. And required Interlocking with other incomer & Bus Coupler to be provided as per Interlocking / operation scheme indicated in Single Line diagram. The MCCB shall have suitable arrangement for termination of cable on incoming side and busbar connection at outgoing side as per single line diagram, complete with following for each incomer:" "1 x 50kA, 2kVp surge arrester with suitable Fuse. 1 x R,Y,B,On,Off,Trip,Spring charge, Service position, test position, ready to close, LED indication lamp with 2A control MCB etc. as required. 1 x (16 window annunciation panel with trip, accept & reset options along with hooter) 1 x (Auxiliary contactor 6 No + 6 NC, suitable for 24 V DC.) " "1 x (start/stop, trip/reset, spring charge, emergency Push buttons, auto/manual switch, test, service, trip circuit healthy, DC healthy indications etc. as required)

-

-

-

... More
1 x (230 V, Single Phase, 50 HZ, AC operated Battery Charger for DG Battery charging only with Boost and trickle charging facility and protection from over charging the battery with voltmeter of range 0-50 Volts and Ammeter of range 0-50 Amp) 1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of THD, KVARH KW, KWH, KVAR, PF, V, A, Hz with 3X400/5A, 15VA Class 1.0 CTs)" "1 x (IDMT based relay module with Ac inverse time overcurrent, instantaneous overcurrent relay, instantaneous earth fault relay, Overvoltage, undervoltage with dead band bypass feature, frequency, phase sequence, reverse power and earth fault relay along with 400/1A, CL-5P10, 15VA, CT) 2 x (Restricted earth fault relay with required CTs)" The Auto Synchronisation and AMF operation of DG Sets shall be carried out by power command center installed on each DG Set by DG Manufacturer however required coordination and provisions to achieve the same in coordination with PLC based Auto Load Management is included in the scope of work of Panel Manufacturer.

-

-

-

... More
Including providing, installation, testing and commissioning of Micro PLC for Auto Load Management as per Logic mentioned in Single Line Diagram, comprising required Auxiliary relays (24V DC, indication lights, Push button, Emergency stop, A/M position switch, Battery charger (230V A/C / 24V DC), Batteries, Digital I/O card, analogue card, 24V DC power supply as required. "Busbar : 850A, 415V, FP, 25 kA/1sec, Electrolytic high conductivity Aluminium busbar insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints." Outgoings : "5 x 250 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release. 5 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 250/5A, 10VA Class 1.0 CTs)" "4 x 100 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release. 2 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 100/5A, 10VA Class 1.0 CTs)" "4 x 63 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release. 4 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, KVAR, PF, V, A, Hz with 63/5A, 10VA Class 1.0 CTs)"

1

-

1550000

... More
Main Fire Panel "Incomer 1 x R,Y,B LED indication lamp with 2A control MCB 1 x 250 A, FP, 36kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release. 1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of PF, V, A, Hz with 3X250/5A, 5VA Class 1.0 CTs)" "Busbar : 350A, 415V, FP, 25 kA/1sec, Aluminium busbar." "Outgoings : 1 x 200 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release. 4 x 100 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with thermal magnetic release. 2 x 63 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with thermal magnetic release. 4 x 40 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with thermal magnetic release.

1

-

480000

... More
Terrace Panel "Incomer: 1 x R,Y,B LED indication lamp with 2A control MCB 1 x 100 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with thermal magnetic based release. 1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KVAR, PF, KWH, V, A with 3X100/5A, 5VA Class 1.0 CTs)" "Busbar : 150A, 415V, FP, 10 kA/1sec, Aluminium busbar." "Outgoings : 6 x 63 A, FP, 10kA, MCB ""C Curve"". 6 x 40 A, FP, 10kA, MCB ""C Curve"". "

1

-

350000

... More
UPS Input Panel (3X60KVA UPS) "Incomer/Outgoing: 3 x R,Y,B LED indication lamp with 2A control MCB 3 x 125 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release. 3 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KWH, V, A with 3X125/5A, 5VA Class 1.0 CTs)"

1

-

50000

... More
UPS Output Panel (3X60KVA UPS) "Incomer/Outgoing: 3 x R,Y,B LED indication lamp with 2A control MCB 3 x 125 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with microprocessor based release." "Busbar : 450A, 415V, FP, 10 kA/1sec, tinned copper busbar." "Outgoings : 10 x 63 A, FP, 10kA, MCB ""D Curve"". 8 x 40 A, FP, 10kA, MCB ""D Curve"". 6 x 32 A, DP, 10kA, MCB ""D Curve"". 6 x 40 A, DP, 10kA, MCB ""D Curve"". "

1

-

150000

... More
FEEDER PILLAR Incomer: 1 x R,Y,B LED indication lamp with 2A control MCB 1 x 63 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection with thermal magnetic based release. 1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of KVAR, PF, KWH, V, A with 3X100/5A, 5VA Class 1.0 CTs) Busbar : 150A, 415V, FP, 25 kA/1sec, Aluminium busbar. Outgoings : 2 Nos. x 40A, FP, RCB0, 10kA 4 Nos. x 32A, FP, RCB0, 10kA 4 Nos. x 10A, FP, RCB0, 10kA 2 Nos. x 40A, FP, MCB, 10kA C Curve.

6

-

150000

... More
Supplying and fixing of 32amp industrial socket outlet, Self locking type including supplying boxes of suitable size,32 amp DP MCB, D Curve and a plug top, complete as required and as per specifications.

20

-

10566.35

... More
Supplying and fixing of 32 amp 3-phase industrial socket enclosure,IP 65 including supplying boxes of suitable size,40 amp TP MCB and complete as required and as per specifications. (IP -65) (Weather Proof).

20

-

12569

... More
Supply, installation, testing and commissioning of 63 A 4P MCB, motor duty in a sheet steel enclosure, single door with required arrangement for incoming and outgoing cable complete as required

20

-

2356.65

... More
Supplying and fixing of 32 amp 1-phase industrial socket outlet including supplying boxes of suitable size, 32 amp DP MCB and a plug top, complete as required and as per specifications. (IP -65) (Weather Proof).

30

-

10566.35

... More
Supplying and fixing of 25 amp 1-phase industrial socket outlet including supplying boxes of suitable size, 25 amp DP MCB and a plug top, complete as required and as per specifications. (IP -65) (Weather Proof).

25

-

10566.35

... More
Supply,installation,testing and commissioning of 100 A TP MCCB with CBCT & ELR, 16 KA service breaking capacity, heavy duty solid neutral link in a sheet steel enclosure with required arrangement for incoming and outgoing cable complete as required.(Weather Proof)

15

-

23015

... More
Supply,installation,testing and commissioning of 63 A TP MCCB with CBCT & ELR, 16 KA service breaking capacity, heavy duty solid neutral link in a sheet steel enclosure with required arrangement for incoming and outgoing cable complete as required.(Weather Proof)

5

-

22877

... More
Supply, installation, testing and commissioning of 40 A 4P RCBO, 30 mA, motor duty in a MS enclosure with required arrangement for incoming and outgoing cable complete as required.

5

-

5915

... More
Supply, installation, testing and commissioning of 40 A 4P 10KA D Curve MCB in a MS enclosure with required arrangement for incoming and outgoing cable complete as required.

10

-

3130

... More
RISING MAINS & BUS DUCTS Sandwich Type Busduct Manufacturing, testing at works supply ,installation,testing and commissioning of Electro galvanised steel enclosure following rating TPN Al sandwitch type Bus Duct, 3 phase, 4 pole with neutral 50% of phase rating (IP-54) suitable for indoor installation with integral earth, Insulation Class B, (130°C) including connecting the bus duct with terminal flanges along with all accessories as required complete including expansion joints as per manufacturer recommendation, , insulating materials, all mounting accessories, necessary steel support structure, down rods, dash fasteners etc. complete as required and as per specifications. 2500 Amp (from DG Sync. Panel to Main LT Panel)

-

-

-

... More
Straight Line Length including vertical & horizontal

40

-

29075

... More
90 degree bends

6

-

5056

... More
End Flange

4

-

11375

... More
Copper flexible

4

-

42723

... More
Rising Main (Sandwich type) Design, Fabrication, Supply, installation, Testing & Commissioning of following adaptor box housings fabricated out of 14G CRCA powder coated (as approved) sheet steel for the Rising Mains fitted with following rating MCCB. The adaptor box shall be totally factory assembled complete with solid aluminium busbar links of rated capacity for connection of outgoing vide MCCB to Risings Mains. The adaptor box should be complete with suitable size of glands plate for incoming cables. 1000A/25KA, TPN MCCB with detachable bus-bar type neutral links & rotary operating mechanism with door interlock & a set of 3 Nos. phase indicating lights,voltmeter, ammeter along with selector switch, CT's and 2A SP MCB.

4

-

210000

... More
Rising Main (Sandwich type) Design, Fabrication, Supply, installation, Testing & Commissioning of following adaptor box housings fabricated out of 14G CRCA powder coated (as approved) sheet steel for the Rising Mains fitted with following rating MCCB. The adaptor box shall be totally factory assembled complete with solid aluminium busbar links of rated capacity for connection of outgoing vide MCCB to Risings Mains. The adaptor box should be complete with suitable size of glands plate for incoming cables. 400A/25KA, TPN MCCB with detachable bus-bar type neutral links & rotary operating mechanism with door interlock & a set of 3 Nos. phase indicating lights,voltmeter, ammeter along with selector switch, CT's and 2A SP MCB.

4

-

65000

... More
Design, manufacture, supply, assembling, installation in correct assigned position, making proper connections, testing and commissioning of following rating Reducer suitable for Rising Mains as described above. )a) 1000 Amps to 800 Amps TPN Reducer

4

-

25000

... More
800 Amps to 600 Amps TPN Reducer

4

-

22000

... More
600 Amps to 400 Amps TPN Reducer

4

-

18000

... More
Design, manufacture, supply, assembling, installation in correct assigned position, making proper connections, testing and commissioning of following rating Reducer suitable for Rising Mains as described above. a) 400 Amps to 200 Amps TPN Reducer

4

-

15000

... More
Design, Fabrication, Supply, unloading, installation, testing & commissioning of following capacity Rising Mains consisting of total Al/ GI. enclosure, TPN high electrolytic conductivity Aluminium conductor, sandwich Busbars covered with 2 layers of Myler insulation, No coloured sleeves, suitable for operation on 415V/650V 3 phase, 4 wire 50 cycles AC supply system. The construction should be such that it will be dust and vermin proof IP 54 in epoxy powder coated Aluminum construction rated for 45 degrees C ambient temperature. The rising mains should be 14 G & front cover in 16 G CRCA painted / powder coated sheet construction rated for 45°C ambient temp. The Rising Mains should be built in convenient sections complete with fire proof barriers, thrust pads, expansion joints at intervals and straps for fixing on the wall or floor mounted arrangement duly marked with the Current carrying capacity. The entire length should be fitted with Integral Earth Aluminium busbar. (25 KA) (a) 1000 A/25 KA.

40

-

30000

... More
(b) 800 A/25 KA.

40

-

28000

... More
(c) 600 A/25 KA.

40

-

24500

... More
(d) 400 A/25 KA.

75

-

20000

... More
Design, Fabrication, Supply, unloading, installation, testing & commissioning of following capacity Rising Mains consisting of total Al/ GI. enclosure, TPN high electrolytic conductivity Aluminium conductor, sandwich Busbars covered with 2 layers of Myler insulation, No coloured sleeves, suitable for operation on 415V/650V 3 phase, 4 wire 50 cycles AC supply system. The construction should be such that it will be dust and vermin proof IP 54 in epoxy powder coated Aluminum construction rated for 45 degrees C ambient temperature. The rising mains should be 14 G & front cover in 16 G CRCA painted / powder coated sheet construction rated for 45°C ambient temp. The Rising Mains should be built in convenient sections complete with fire proof barriers, thrust pads, expansion joints at intervals and straps for fixing on the wall or floor mounted arrangement duly marked with the Current carrying capacity. The entire length should be fitted with Integral Earth Aluminium busbar. (25 KA) (a) 200 A/25 KA.

40

-

30000

... More
UPS Supplying, installation, testing and commissioning of following size, 3Phase Input-3Phase output, online double conversion fully microprocessor based ,indoor type, compact UPS system suitable for parallel operation with IGBT based PWM technology to achieve THD 3% and input power factor of greater than 0.95 at 50% loading,suitable for three phase AC input voltage 380 V to 440 V, 50 Hz +3% / - 3 % and three phase AC output voltage 415 ± 1% volts & frequency 50 ± 0.5 Hz , inbuilt isolation transformer, necessary VRLA batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable (for UPS to Battery and battery to battery), static and maintenance bypass switch, SNMP card for RS232/ ethernet IP computability for operation and monitoring etc. with all components as mentioned in BOQ, specifications and schedule, complete as required. Note : Concerning vendor needs to furnish the battery sizing calculations at the time of GA approval and battery size has to be as per the approved GA drawing. (a) 60 KVA

2

-

1200000

... More
UPS Supplying, installation, testing and commissioning of following size, 3Phase Input-3Phase output, online double conversion fully microprocessor based ,indoor type, compact UPS system suitable for parallel operation with IGBT based PWM technology to achieve THD 3% and input power factor of greater than 0.95 at 50% loading,suitable for three phase AC input voltage 380 V to 440 V, 50 Hz +3% / - 3 % and three phase AC output voltage 415 ± 1% volts & frequency 50 ± 0.5 Hz , inbuilt isolation transformer, necessary VRLA batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable (for UPS to Battery and battery to battery), static and maintenance bypass switch, SNMP card for RS232/ ethernet IP computability for operation and monitoring etc. with all components as mentioned in BOQ, specifications and schedule, complete as required. Note : Concerning vendor needs to furnish the battery sizing calculations at the time of GA approval and battery size has to be as per the approved GA drawing. (a) 5KVA Single Phase Output

1

-

90000

... More
CABLES & TERMINATIONS

-

-

-

... More
Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. (a) 3.5C X 300 Sqmm A2XFY.

865

-

1146.63

... More
(b) 3.5C X 240 Sqmm A2XFY.

200

-

934.94

... More
(c) 3.5C X 185 Sqmm A2XFY.

176

-

743

... More
(c) 3.5C X 150 Sqmm A2XFY.

650

-

596.47

... More
(d) 3.5C X 120 Sqmm A2XFY.

70

-

503.86

... More
3.5C X 95 Sqmm A2XFY.

25

-

402

... More
(e) 3.5C X 70 Sqmm A2XFY.

490

-

334.07

... More
(f) 3.5C X 50 Sqmm A2XFY.

1805

-

245.86

... More
(g) 4C X 35 Sqmm A2XFY.

1135

-

210.58

... More
(h) 4C X 25 Sqmm A2XFY.

1365

-

162.07

... More
(i) 4C X 16 Sqmm 2XWY.

2082

-

606.39

... More
(j) 4C X 16 Sqmm 2XY.

2565

-

558.98

... More
(j) 4C X 10 Sqmm 2XWY.

2505

-

361.63

... More
(k) 4C X 10 Sqmm 2XY.

2900

-

344

... More
4C X 6 Sqmm 2XWY.

948

-

265

... More
4C X 6 Sqmm 2XY.

2115

-

248

... More
4C X 4 Sqmm 2XWY.

195

-

168

... More
4C X 4 Sqmm 2XY.

65

-

176

... More
3C X 16 Sqmm 2XWY.

33

-

440

... More
3C X 16 Sqmm 2XY.

75

-

416

... More
3C X 10 Sqmm 2XWY.

330

-

340

... More
3C X 10 Sqmm 2XY.

752

-

320

... More
3C X 6 Sqmm 2XWY.

1455

-

176

... More
3C X 6 Sqmm 2XY.

1255

-

155

... More
3C X 4 Sqmm 2XWY.

440

-

127

... More
3C X 4 Sqmm 2XY.

20

-

140

... More
1C X 120 sqmm 2XWY

110

-

680

... More
1C X 95 sqmm 2XWY

330

-

624

... More
1C X 70 sqmm 2XWY

100

-

544

... More
1C X 50 sqmm 2XY

790

-

472

... More
1C X 35 Sqmm 2XWY.

440

-

341

... More
1C X 35 sqmm 2XY

945

-

320

... More
1C X 25 sqmm 2XY

264

-

227

... More
1C X 10 sqmm 2XY

880

-

147

... More
1C X 6 sqmm 2XY

300

-

110

... More
2C X 6 sqmm 2XWY

3960

-

179

... More
4C X 6 sqmm A2XFY

2200

-

110

... More
Supplying following 1.1kV grade, XLPE insulated, FRLS type control cables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required. (a) 2C X 2.5 sqmm copper conductor

150

-

88.2

... More
(b) 4C X 2.5 sqmm copper conductor

150

-

139.19

... More
(c) 6C X 2.5 sqmm copper conductor

70

-

192.94

... More
(d) 10C X 2.5 sqmm copper conductor

70

-

288.04

... More
(e) 21C X 2.5 sqmm copper conductor

70

-

643.6

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1kV grade of following size in the existing RCC trench / Hume pipe / pipe complete as required. (a) Up to 35 sqmm

3003

-

31

... More
(b) Above 35 sqmm and up to 95 sqmm

935

-

47

... More
(c) Above 95 sqmm and up to 185 sqmm

402

-

64

... More
(d) Above 185 sqmm and up to 400 sqmm

-

-

112

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. (a) Upto 35 sq. mm (clamped with 1mm thick saddle)

27028

-

33

... More
(b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

3740

-

74

... More
(c) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

604

-

93

... More
(d) Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

320

-

150

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (a) 3½ X 300 sq. mm (70 mm)

34

-

936

... More
(b) 3½ X 240 sq. mm (62 mm)

6

-

809

... More
3½ X 185 sq. mm (57mm)

10

-

702

... More
(c) 3½ X 150 sq. mm (50 mm)

20

-

555

... More
(d) 3½ X 120 sq. mm (45 mm)

4

-

489

... More
3½ X 95 sq. mm (45 mm)

4

-

473

... More
(e) 3½ X 70 sq. mm (38mm)

28

-

368

... More
(f) 3½ X 50 sq. mm (35 mm)

142

-

329

... More
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (a) 4C X 35 Sqmm A2XFY.

44

-

128.17

... More
(b) 4C X 25 Sqmm A2XFY.

40

-

126.79

... More
(c) 4C X 16 Sqmm 2XWY.

64

-

286.66

... More
(d) 4C X 16 Sqmm 2XY.

82

-

286.66

... More
(e) 4C X 10 Sqmm 2XWY.

86

-

278.39

... More
(f) 4C X 10 Sqmm 2XY.

136

-

265

... More
(g) 4C X 6 Sqmm 2XWY.

38

-

190.19

... More
(h) 4C X 6 Sqmm 2XY.

48

-

185

... More
4C X 4 Sqmm 2XY.

4

-

160

... More
4C X 4 Sqmm 2XWY.

4

-

189

... More
(i) 3C X 16 Sqmm 2XWY.

16

-

278.39

... More
(j) 3C X 16 Sqmm 2XY.

2

-

265

... More
(k) 3C X 10 Sqmm 2XWY.

12

-

278.39

... More
(l) 3C X 10 Sqmm 2XY.

26

-

260

... More
(m) 3C X 6 Sqmm 2XWY.

40

-

190.19

... More
(n) 3C X 6 Sqmm 2XY.

66

-

190.19

... More
3C X 4 Sqmm 2XWY.

18

-

189

... More
3C X 4 Sqmm 2XY.

2

-

160

... More
1C X 120 sqmm 2XWY

4

-

240

... More
1C X 95 sqmm 2XWY

40

-

170

... More
(o) 1C X 70 sqmm 2XWY

8

-

210

... More
(q) 1C X 50 sqmm 2XY

72

-

190.19

... More
(s) 1C X 35 sqmm 2XY

60

-

270

... More
1C X 25 sqmm 2XY

24

-

295

... More
1C X 16 sqmm 2XY

8

-

109

... More
(t) 1C X 10 sqmm 2XY

80

-

106.12

... More
(u) 1C X 6 sqmm 2XY

120

-

80

... More
(v) 2C X 6 sqmm 2XWY

180

-

179.16

... More
(x) 4C X 6 sqmm A2XFY

-

-

173.65

... More
(y) 2C X 2.5 sqmm copper conductor

8

-

124.03

... More
(z) 4C X 2.5 sqmm copper conductor

8

-

129.55

... More
6C X 2.5 sqmm copper conductor

4

-

186.05

... More
10C X 2.5 sqmm copper conductor

4

-

279.77

... More
21C X 2.5 sqmm copper conductor

4

-

341.78

... More
CABLES TRAYS & RACEWAYS Supply and installation of following sizes of GI ladder type cable trays and necessary bends, tees, reducer couplers, dashfastners,GI nuts bolts including cutting,bending, drilling, bolting required suspension arrangement fabricated from steel etc.complete as per specifications and as approved by Engineer - in - charge. For the suspension of GI cable tray, only GI round rods with ceiling anchoring facility should be used. (a) 1000 mm wide, 100 mm high, 2.6 mm thick ladder type cable tray.

40

-

1405.27

... More
(b) 750 mm wide, 100 mm high, 2.6 mm thick ladder type cable tray.

40

-

1250.71

... More
(c) 600 mm wide, 100 mm high, 2.6 mm thick ladder type cable tray.

80

-

1157.98

... More
(d) 450 mm wide, 100 mm high, 2.6 mm thick ladder type cable tray.

40

-

1065.24

... More
(e) 300 mm wide, 100 mm high, 2.6 mm thick ladder type cable tray.

80

-

972.5

... More
Supply and fixing of following sizes of MS Painted channels, 14 gauge, with openable cover with all accessories as required including junction boxes,colour coded with orange colour for power and blue colour for elv, laid in floor including marking the routing,getting it approved,cutting the floor,filling and plastering after laying the raceway,grouting the raceway to the floor,sealing of raceway cover,joints and junction boxes complete as required. Required junction boxes will be provided for smooth pulling of structured and power cabling. It will be the responsibility of the contractor to coordinate with structured cabling contractor for laying of cable. (a) 50 mm x 40 mm (2 mm thick cover)

400

-

513.98

... More
100 mm x 40 mm (2 mm thick cover)

700

-

656

... More
(b) 150 mm x 40 mm (2 mm thick cover)

200

-

803.78

... More
200 mm x 40mm (3 mm thick cover)

900

-

1094

... More
(c) 300 mm x 40 mm (3 mm thick cover)

1500

-

1454.22

... More
Supply and fixing of following sizes of MS Painted channels 14 gauge, with openable cover, with all accessories as required including junction boxes, orange colour for power and blue colour for data or as suggested by architect/engineer incharge, suspended from the ceiling including providing suspension arrangement with all accessories in an approved manner complete as required. Required junction boxes will be provided for smooth pulling of structured and power cabling.It will be the responsibility of the contractor to coordinate with structured cabling contractor for laying of cable. (a) 50 mm x 50 mm (2 mm thick cover)

50

-

539.74

... More
100 mm x 50 mm (2 mm thick cover)

700

-

681

... More
(b) 150 mm x 50 mm (2 mm thick cover)

100

-

823.1

... More
200 mm x 50 mm (2 mm thick cover)

1100

-

971

... More
(c) 300 mm x 50 mm (2 mm thick cover)

2000

-

1254.58

... More
Supply and fixing of following sizes of MS painted channel,14 gauge, with openable cover and all accessories as required for fixing on wall/ column complete as required including providing junction boxes,bends and tees as required. (a) 50 mm x 50 mm (2 mm thick cover)

30

-

535.87

... More
(b) 100 mm x 50 mm (2 mm thick cover)

30

-

677.55

... More
150 mm x 50 mm (2 mm thick cover)

80

-

819.23

... More
200 mm x 50 mm (2 mm thick cover)

130

-

967.35

... More
300 mm x 50 mm (2 mm thick cover)

150

-

1250.71

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (a) 100 mm width x 50 mm depth x 1.6 mm thickness

40

-

599

... More
(b) 150 mm width x 50 mm depth x 1.6 mm thickness

210

-

644

... More
(c) 300 mm width x 50 mm depth x 1.6 mm thickness

800

-

875

... More
(d) 450 mm width x 50 mm depth x 2 mm thickness

500

-

1213

... More
(e) 900 mm width x 62.5 mm depth x 2 mm thickness

120

-

2405

... More
(f) 600 mm width x 75 mm depth x 2 mm thickness

60

-

1795

... More
(g) 750 mm width x 75 mm depth x 2 mm thickness

40

-

2090

... More
(h) 900 mm width x 75 mm depth x 2 mm thickness

40

-

2411

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (a) 100 mm width X 50 mm depth X 1.6 mm thickness

7

-

1063

... More
(b) 150 mm width X 50 mm depth X 1.6 mm thickness

21

-

1168

... More
(c) 300 mm width X 50 mm depth X 1.6 mm thickness

80

-

1713

... More
(d) 450 mm width x 50 mm depth x 2 mm thickness

50

-

2490

... More
(e) 900 mm width x 62.5 mm depth x 2 mm thickness

12

-

5221

... More
(f) 600 mm width x 75 mm depth x 2 mm thickness

6

-

3832

... More
(g) 750 mm width x 75 mm depth x 2 mm thickness

4

-

4525

... More
(h) 900 mm width x 75 mm depth x 2 mm thickness

4

-

5243

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (a) 100 mm width X 50 mm depth X 1.6 mm thickness

3

-

1220

... More
(b) 150 mm width X 50 mm depth X 1.6 mm thickness

7

-

1274

... More
(c) 300 mm width X 50 mm depth X 1.6 mm thickness

27

-

1997

... More
(d) 450 mm width x 50 mm depth x 2 mm thickness

16

-

2920

... More
(e) 900 mm width x 62.5 mm depth x 2 mm thickness

4

-

6164

... More
(f) 600 mm width x 75 mm depth x 2 mm thickness

2

-

4508

... More
(g) 750 mm width x 75 mm depth x 2 mm thickness

2

-

5335

... More
(h) 900 mm width x 75 mm depth x 2 mm thickness

2

-

6189

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (a) 100 mm width X 50 mm depth X 1.6 mm thickness

2

-

1220

... More
(b) 150 mm width X 50 mm depth X 1.6 mm thickness

5

-

1274

... More
(c) 300 mm width X 50 mm depth X 1.6 mm thickness

20

-

2194

... More
(d) 450 mm width x 50 mm depth x 2 mm thickness

13

-

3320

... More
(e) 900 mm width x 62.5 mm depth x 2 mm thickness

4

-

6164

... More
(f) 600 mm width x 75 mm depth x 2 mm thickness

1

-

4510

... More
(g) 750 mm width x 75 mm depth x 2 mm thickness

2

-

3942

... More
(h) 900 mm width x 75 mm depth x 2 mm thickness

2

-

4562

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (a) 100 mm width X 50 mm depth X 1.6 mm thickness

2

-

1528

... More
(b) 150 mm width X 50 mm depth X 1.6 mm thickness

5

-

1778

... More
(c) 300 mm width X 50 mm depth X 1.6 mm thickness

20

-

2242

... More
(d) 450 mm width x 50 mm depth x 2 mm thickness

13

-

3459

... More
(e) 900 mm width x 62.5 mm depth x 2 mm thickness

4

-

6918

... More
(f) 600 mm width x 75 mm depth x 2 mm thickness

1

-

4893

... More
(g) 750 mm width x 75 mm depth x 2 mm thickness

2

-

6036

... More
(h) 900 mm width x 75 mm depth x 2 mm thickness

2

-

6996

... More
DISTRIBUTION BOARD

-

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door

15

-

1061

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door

65

-

1151

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way (4 + 18), Double door

5

-

3693

... More
(B) 8 way (4 + 24), Double door

150

-

4601

... More
© 12 way (4 + 36), Double door

25

-

4935

... More
Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (a) 8 way Double door (8 + 24)

15

-

7744

... More
(b) 12 way Double door (8 + 36)

35

-

9828

... More
Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. (a) For 8 way, Double door TPN MCBDB

150

-

728

... More
(b) For 12 way, Double door TPN MCBDB

25

-

1812.45

... More
Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

50

-

433

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole

5175

-

173

... More
(b) Double pole

80

-

463

... More
Supplying and fixing 40 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Double pole

80

-

866.31

... More
(b) Triple pole

270

-

1376.25

... More
© Four pole

60

-

1737.9

... More
Single pole

5

-

437

... More
Supplying and fixing 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four pole

150

-

1737.9

... More
Supplying and fixing 32 amps rating, 415 volts, four pole ,"C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.

60

-

1224.05

... More
Supplying and fixing following rating, 240 volts, double pole ,"C" curve, residual current break over (RCBO) suitable for inductive load of following capacities in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 25A, 30mA, 10 kA DP RCBO

35

-

2299.21

... More
(b) 32A, 30mA, 10 kA DP RCBO

35

-

2300.51

... More
(c) 40A, 30mA, 10 kA DP RCBO

90

-

2896.31

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB) having sensitivity up to 30milliampere in the existing MCB DB complete with connections, testing commissioning etc. as required. (a) 25 amps

10

-

1650

... More
(b) 40 amps

88

-

1719

... More
(c) 63 amps

38

-

2242

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

800

-

7

... More
Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.

30

-

627

... More
Supplying and fixing TP sheet steel enclosure on surface/ recessed along with 16/25/32 A, 415 V “C” curve TP MCB complete with connections, testing and commissioning etc. as required.

40

-

878

... More
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in the cubical panel, making connections etc. as required. (for VTPN DB) (a) 100 A, 16kA, TP MCCB

70

-

3218

... More
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

35

-

1455

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

42

-

849

... More
Supplying and fixing 32 amp, 240 Volts, SPN industrial type socket outlet with 2 pole and earth, enclosed plug top , in IP-65 enclosure, on surface or in recess, with cover for socket outlet, IK-08, with interlocking switch and complete with connections , testing commissioning etc. as required.

10

-

6170.45

... More
Supplying and fixing 63 amp, 415 Volts, waterproof TPN industrial type, IP 65 for kitchen socket outlet with 4 pole and earth within polycarbonate enclosure, plug top on surface or in recess, with cover for socket outlet ,IK-08, with interlocking switch and complete with connections , testing commissioning etc. as required.

5

-

13916.38

... More
Supplying, installation, testing and commissioning of single phase automatic changeover and current limiter for distribution boards capable to trip main incomer in case of demand increase from 2KW only in case of secondary supply (DG) and shall also automatically switch to mains and secondary source without interuption complete as required and upto satifaction of engineer incharge.

54

-

2500

... More
WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

-

-

-

... More
Group A

548

-

1600

... More
Group B

2500

-

615

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

600

-

809

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (a) 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire.

3420

-

112

... More
(b) 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire.

11400

-

137

... More
(c) 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire

19000

-

168

... More
(d) 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire

3180

-

227

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the exisitng surface or recessed steel/PVC conduit as required (also in existing metallic raceways) (a) 3 x 2.5 sq.mm.

1350

-

75

... More
(b) 3 x 4 sq.mm.

3300

-

111

... More
(c) 3 x 6 sq.mm.

636

-

162

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate / switch box including connections but excluding modular plate etc. as required.

572

-

387

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

1300

-

24

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

95

-

61

... More
Installation of exhaust fan in the existing opening , including making good the damage, connection, testing commissioning etc. as required. (a): Up to 450mm sweep

143

-

224

... More
(b) Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes.

143

-

99

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.

160

-

533

... More
Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 A, for mounting height up to 2.8 meter and for 5 meter diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.

5

-

3193

... More
Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor with day light dimming(lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.) having high preformance, regulating programmable type, suitable for connected load upto 10 A, for mounting height up to 2.8 meter and for 5 meter diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.

1

-

4467

... More
Supplying and fixing minimum IP 65 rated adaptor with transparent flap suitable for minimum 4 modules, modular type switch/socket in recess/surface complete etc. as required but excluding the cost of switch/socket.

20

-

1970.06

... More
Supplying and fixing 6 Module pop-up type flush mounting boxes for, modular type switch/socket/telephone/data points in recess/surface complete etc. as required but excluding the cost of switch/socke/telephone and data point.

30

-

2386.14

... More
Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) Remark: The item shall be executed for the suspended light points.

80

-

32

... More
Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

572

-

132

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (a) 40 mm

550

-

293

... More
(b) 50 mm

120

-

389

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 40 mm

100

-

137

... More
50 mm

40

-

218

... More
Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required.

572

-

112

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

572

-

130

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (a) 1 or 2 Module

762

-

83

... More
(b) 3 Module

2740

-

93

... More
(c) 4 Module

180

-

103

... More
(d) 6 Module

300

-

133

... More
(e) 8 Module

90

-

174

... More
(f) 12 Module

25

-

213

... More
Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. (a) 5/6 amps switch

820

-

98

... More
(b) 15/16 amp switch

60

-

125

... More
(c) 3 pin 5/6 amp socket outlet

1860

-

120

... More
(d) 6 pin 15/16 amp socket outlet

1160

-

171

... More
(e) Telephone socket outlet

115

-

103

... More
(f) TV antenna socket outlet

140

-

103

... More
(g) Bell Push

35

-

114

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable

750

-

34

... More
EARTHING & LIGHTNING PROTECTION

-

-

-

... More
(a) Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.

18

-

3672

... More
(b) Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

46

-

4327

... More
(c) Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

16

-

11703

... More
(d) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

2700

-

37

... More
(e) Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

5500

-

141

... More
(f) Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

300

-

351

... More
(g) Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

150

-

1131

... More
(h) Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

230

-

976

... More
(i) Providing and fixing of lightning conductor finial , made of 25mm dia 300mm long Copper tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate including holes etc. complete as required.

20

-

371

... More
(j) Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For Horizontal run)

1500

-

67

... More
(j) Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)

410

-

86

... More
(k) Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

18

-

68

... More
(l) Providing and fixing 50 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required.

300

-

352.25

... More
(m) Providing and fixing 50m X 5 mm copper strip on surface or in recess for connections etc. as required.

100

-

1845

... More
FIXTURES & FANS Supply, Installation, Testing and Commissioning of following Points inside the building. All the below mentioned points shall be wired as per the described scheme and with 1.1kV grade, FRLS type of Cu. The primary shall mean the first light point connected to switch and secondary means rest all points looped with the said primary. The said wires shall have stranded conductors and proper gauge. The rate shall include complete Supply, Installation, Testing and Commissioning rates including cost of conceled PVC conduit in slab along with the cost of electronic drivers, ballasts, capacitors, ignitors, ceiling rose / connectors / angle holders , lugs and all tools and accessories required to as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. (a) 34W, surface , ( 2' x 2' ), fitting with LED fixture, efficacy = 100 lumens / watt with inbuilt electronic driver and 50,000 burning hours and IP-20 rated enclosure with suitable diffuser complete as required

524

-

4600

... More
34W, recessed , ( 2' x 2' ), fitting with LED fixture, efficacy = 100 lumens / watt with inbuilt electronic driver and 50,000 burning hours and IP-20 rated enclosure with suitable diffuser complete as required

922

-

4600

... More
28W, batten fitting with LED fixture, efficacy = 100 lumens / watt with inbuilt electronic driver and 50,000 burning hours and IP-20 rated enclosure with suitable diffuser complete as required

334

-

3000

... More
15W, Surface , table lamp light fitting with LED fixture, efficacy = 100 lumens / watt with inbuilt electronic driver and 50,000 burning hours and IP-20 rated enclosure with suitable diffuser complete as required

180

-

4200

... More
Supplying, installation, testing & commissioning of 2x18W recessed mounting type LED luminaire, IP 20 ,colour temperature 5700-6500K, THD ≤ 20%, CRCA/aluminium housing, suitable diffuser, inbuilt electronic driver, including 3 core 1.5 sq.mm FRLS PVC insulated and PVC sheathed copper conductor cable and earthing etc. upto suitable point complete as required.

310

-

1800

... More
45W, recess ,spot light fitting with LED fixture, efficacy = 100 lumens / watt with inbuilt electronic driver and 50,000 burning hours and IP-20 rated enclosure with suitable diffuser complete as required

224

-

3800

... More
7W, mirror light batten fitting with LED fixture, efficacy = 60 lumens / watt with inbuilt electronic driver and 50,000 burning hours and IP-20 rated enclosure with suitable diffuser complete as required

180

-

800

... More
Supplying installation testing & commissioning of 8-9W , outdoor wall/recessed mounting type LED luminaire, IP 65 ,colour temperature 3000 K having efficacy not less than 25 lm/W, CRI ≥ 70 ,THD ≤ 10%, CRCA / die cast aluminium housing, suitable diffuser, inbuilt electronic driver, including 3 core 1.5 sq.mm FRLS PVC insulated and PVC sheathed copper conductor cable and earthing etc. upto suitable point complete as required.

33

-

3000

... More
15W, bulk head fitting with LED fixture, efficacy = 70 lumens / watt with inbuilt electronic driver and 50,000 burning hours and IP-40 rated enclosure with suitable diffuser complete as required

30

-

3200

... More
Supply of BEE 5star rated following ceiling fan, including wiring, the down rods of standard length (upto 30 cm) with 3x1.5 sqmm FRLS PVC insulated copper conductor single core cables etc., as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. 1200 mm sweep ceiling fan

520

-

1800

... More
Supply of 300mm size exhaust fan suitable for 230V, 50 Hz AC including modifying and finishing for hole/opening for the size of fan, MS louver/ shutter complete with frame for Ex.fan including its connection with 3x1.5 sq mm FRLS copper conductor wire with PVC sleeve, loop earthing, making the good damage complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge.

130

-

1100

... More
MISCELLANEOUS WORKS

-

-

-

... More
Providing & fixing in position 1000 mm wide , Electrical Insulating Rubber Mats as per IS 15652:2006, 2 mm thick, suitable up to 11 KV , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top)

60

-

1500

... More
Providing & fixing in position 1000 mm wide , Electrical Insulating Rubber Mats as per IS 15652:2006, 2 mm thick, suitable up to 1.1 KV , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top)

180

-

950

... More
Supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 Sq Metre )

4

-

310

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

4

-

145

... More
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

180

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

30

-

595

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

15

-

530

... More
DATA AND NETWORKING

-

-

-

... More
Supply & Installation of CAT 6 information outlets complying fully or exceeding with category 6 connecting hardware specifications for all pair combinations up to 250 MHz. Outlets shall use lead frame technology, non PCB pyramid type. (Yellow in Colour for Data) complete as required and as per technical specifications.

410

-

373.52

... More
Supply & Installation of CAT 6 information outlets complying fully or exceeding with category 6 connecting hardware specifications for all pair combinations up to 250 MHz. Outlets shall be use lead frame technology, non PCB pyramid type. (Blue in Colour for Voice) complete as required and as per technical specifications.

175

-

373.52

... More
Supply & Installation of Dual Face Plates along with clearly printed labels and holders complete as required and as per technical specifications.

35

-

212.52

... More
Supply & Installation of Single Face Plates along with clearly printed labels and holders complete as required and as per technical specifications.

310

-

186.76

... More
Supply & Installation of Cat 6 Mounting Cords 4 feet length for the Rack End Connectivity to the System, End shall be RJ 45 with snagless boots. (Yellow in colour for Data) complete as required and as per technical specifications.

702

-

373.52

... More
Supply & Installation of Cat 6 Mounting Cords 7 feet length for the User End Connectivity to the System, End shall be RJ 45 with snagless boots. (Yellow in colour for Data) complete as required and as per technical specifications.

702

-

386.4

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable

18550

-

49

... More
Supply, Installation, Testing and Commissioning of LC-LC single mode duplex fiber optic patch cord 1mtr as per tender specification etc. as required.

20

-

3284.4

... More
Supply, Installation, Testing and Commissioning of LC-LC single mode duplex fiber optic patch cord 2mtr as per tender specification etc. as required.

20

-

3670.8

... More
Supply, Installation, Testing and Commissioning of LC-LC single mode duplex fiber optic patch cord 3mtr as per tender specification etc. as required.

20

-

3799.6

... More
Supply, Installation, Testing and Commissioning of LC type single mode pre-terminated pigtail 1mtr as per tender specification etc. as required.

10

-

2898

... More
Supplying, Installation, testing and commissioning of following sizes of 0.5 mm dia annealed tinned copper conductor PVC insulated and PVC sheathed unarmoured telephone cable on surface/ existing cable tray/inside exisitng conduit complete as required and as per technical specifications. 100 Pair

200

-

2318

... More
Supplying, Installation, testing and commissioning of following sizes of 0.5 mm dia annealed tinned copper conductor PVC insulated and PVC sheathed unarmoured telephone cable on surface/ existing cable tray/inside exisitng conduit complete as required and as per technical specifications. (a) 25 pair

900

-

644

... More
(b) 2 Pair

2800

-

20

... More
(c) 4 Pair

100

-

29

... More
Supply, Installation, Testing and Commissioning of outdoor 6 core armoured Single mode fiber optic cable for outdoor connectivity where ever required in prelaid conduits / RCC hume pipes/HDPE/DWC, whichever maybe available etc. as required.

300

-

175.17

... More
Supplying and fixing in position MS anodised box for data/voice outlet suitable for fixing of RJ 45 jack complete as required. (For Data/voice outlets)

585

-

18079.66

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

1460

-

33

... More
Supply, Installation, Testing and Commissioning of 8 Way tap off for taking TV cable taps from main riser from dish antenna to be installed inside the shaft etc as reqired.

13

-

1223.6

... More
Supply, Installation, Testing and Commissioning of 6 way splitter for TV made up of solid metal die cast housing with 1 male and 6 female complete as required.

6

-

644

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (a) 25 mm

350

-

165

... More
(b) 32 mm

100

-

203

... More
IP BASED CCTV SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of UL Listed IP CCTV fixed dome Coloured Camera, 2 megapixel, Full HD (1920 x 1080) high resolution,1/3” Progressive scan CMOS, 0.2 lux with 3.6/6 mm auto iris lens or equivalent high definition, motion detection,120dB wide dynamic range, H.265 / H.264 / MPEG4 / MJPEG, quad stream, Bit rate 32 Kbps-16Mbps, 12 VDC ± 10%, PoE (802.3af), with ONVIF supported, in built HD card slot up to 32 GB, connectors complete as required in dome shape fixed type for mounting recessed in false ceiling or mounted on wall complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

151

-

9000

... More
Supply, installation, testing and commissioning of UL/CE Listed IP CCTV Coloured Camera, 2 megapixel (1280 x 960) high resolution, 1/3” Progressive scan CMOS, 0.01@F1.2, AGC ON. 0 Lux with IR on, H.264 / MPEG4 / MJPEG, Dual stream, Bit rate 32 Kbps-16Mbps, Standard IP66, 12 VDC ± 10%, PoE (802.3af), 2.7 to 9 mm auto iris lens or equivalent high definition,IR range 20-30 mtr, motion detection, with ONVIF supported, connectors complete as required IR Bullet type mounted on wall complete as per tender specifications required.

30

-

15000

... More
Supply , Installation , Testing and Comissioning of 64 Channel,NVR H.265,H.264 Recording and Playback , Embedded Windows OS on a SSD Drive, Pre-Installed VMS with licenses,Intel Based i7 Processor , 8GB RAM , Intel HD Graphics , Throughput 500Mbps RAID 5 Support , USB 3.0 x 2 + USB 2.0 x 3 , 8 HDD Drives with storage capacity of 80TB .

4

-

650000

... More
Supply, installation, testing & commissioning with proper connection & termination of following size equipment rack made out of CRCA sheet to house all the control equipment complete as required in accordance with laid specification or upto the satisfaction of engineer in charge. (a) 19" equipment rack -15 U

11

-

13098.96

... More
(b) 19" equipment rack -42 U

2

-

64535.24

... More
Supply, installation, testing and commissioning of web Managed switches - 24 Port PoE 10/100 EB Switch with 2 Fiber uplinks including Fibre module for LAN base feature set with support to integration with CCTV, with all related hardware (Weather Proof 16 gauge box MS powder coated) (L2 Switch)

7

-

84210.73

... More
Supply, installation, testing and commissioning of web Managed switches - 16 Port PoE 10/100 EB Switch with 2 Fiber uplinks including Fibre module for LAN base feature set with support to integration with CCTV, with all related hardware (Weather Proof 16 gauge box MS powder coated) (L2 Switch)

3

-

64535.24

... More
Supply, installation, testing and commissioning of following size colour TFT Monitor including decodes and all accessories complete as required in accordance with laid specification or upto the satisfaction of engineer in charge. 21" LCD Display

11

-

19281.36

... More
Supply installation, testing and commissioning of Desktop Computer comprising CPU, Keyboard and a mouse complete with operating system (OS) and other required software to control NVR in control room including Centralized Video Management Software as per the requirement of the successful operation of the surveillance system complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

2

-

83720

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable

7400

-

38

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (a) 25 mm

350

-

165

... More
(b) 32 mm

40

-

203

... More
FIRE ALARM & DIGITAL VOICE EVACUATION SYSTEM Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 10 loops modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card,minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.

1

-

454986

... More
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.

787

-

2846

... More
Supplying, installation, testing & commissioning of fault isolator complete with base as required.

55

-

3257

... More
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED,metallic cover complete with all connections etc as required.

235

-

263

... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required.

35

-

3859

... More
Supply, installation, testing & commissioning of UL Listed 2 way communication Fire Fighter's Telephone Jack on Stainless Steel Plate complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

22

-

4583.99

... More
Supplying, installing, testing and commissioning of addressable telephone module suitable for fire fighters telephone system.

2

-

3820.21

... More
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.

2

-

5727

... More
Supply, installation, testing & Commissioning of UL Listed addressable directional sounder, ( sound output of minimum 90 dB upto a distance of 10 feet) with strobe light of minimum 75 cd intensity with power supply arrangement complete as required and suitable for wall/ceiling mounting in accordance with laid specification or upto the satisfaction of engineer in charge.

35

-

18203.3

... More
Supply, installation, testing & Commissioning of UL Listed addressable monitor module complete as required in accordance with laid specification or upto the satisfaction of engineer in charge. (For monitoring of sprinkler flow switch, Developer's fire panel, WLD Panel)

22

-

3620.57

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required. For control of AHU's, VRV, Hooters ,output to PA system, for integration with Access Control, Developer's Fire Panel etc. complete as required and as per specifications.

22

-

2990

... More
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.

1

-

200148

... More
Supply, installation, testing & commissioning with proper connection & temination of 19" equipment rack made out of CRCA sheet to house all the control equipment complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

1

-

32844

... More
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required.

2

-

74778

... More
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.

6500

-

328

... More
Supplying & Fixing in position MS anodised Box for installation of detectors on true Ceiling complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge.

553

-

115.92

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (a) 25 mm

200

-

147

... More
(b) 32 mm

20

-

198

... More
Supply, Installation, Testing and Commissioning of interface for interconnecting multiple fire alarm system panels over fiber optics media based communication, transceivers or optics must support 100Mbps as per technical specification etc. as required.

1

-

103695.59

... More
Supply, Installtion, Testing and Commissioning of BaCNet interface for IBMS integration using Ethernet TCP/IP as per technical specification etc. as required.

1

-

213456.38

... More
Supply, installation,testing and commissioning of EXIT light, self contained 6W luminaire complete with flush mounting frame ,sign label,fluorescent tube and battery and with label EXIT/RIGHT/LEFT/UP/DOWN as required..

30

-

5748.34

... More
PUBLIC ADDRESS SYSTEM

-

-

-

... More
Supply, installation, testing & commissioning with proper connection & temination of Voice Alarm Call Station having gooseneck condenser microphone with zone Selection Keys and an All-Call-Key, PTT Switch, selectable gain, speech filter and limiter for improved intelligibility, LED indication for zone selection, fault and emergency state

2

-

35000

... More
Supply, installation, testing & commissioning with proper connection & temination of controller having features like announcement to 4 zones expandable to 60 zones, built in required booster amplifier, emergency microphone on the front panel, 16 priority levels including emergency, music to selected zones can be played, upto 255 messages can be stored in the internal 16MB flash ROM, individual BGM volume control for each zone, Digital pre-recorded messages can be merged, full system supervision.

5

-

150000

... More
Supply, installation, testing & commissioning with proper connection & temination of booster Amplifier capable of delivering required Wattage RMS power output for all speakers mentioned in BOQ, built-in fan for temperature control, built in line matching transformer distortion typically 3% @1 KHz, S/N 80 dB complete as required.

2

-

125000

... More
Supply, installation, testing & commissioning of CD/MP3/DVD player with AM/FM tuner complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

2

-

25000

... More
Supply, installation, testing & commissioning with proper connection & temination of 19" equipment rack made out of CRCA sheet to house all the control equipment complete as required in accordance with laid specification or upto the satisfaction of engineer in charge.

3

-

21000

... More
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.

560

-

952

... More
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.

560

-

1780

... More
Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required.

25

-

2416

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Single pair, 2-core, 1.5 sqmm

8775

-

51

... More
Supplying and fixing in position following sizes of 1.6 mm thick GI conduits including providing all accessories concealed/ exposed as required. 25 mm dia GI conduit complete with all fixing accessories. (For PA system wiring)

132000

-

147

... More
VARIABLE REFRIGERANT FLOW SYSTEM (ACADEMIC BLOCK) Supply, installation, testing and commissioning of floor mounted type VRV / VRF air conditining system including following indoor & outdoor units, refrigerant piping, refnet connections, individual controller, first charge of 410A refrigerant. The system shall be able to work on heating or cooling at a time. Supply, installation, testing and commissioning of outdoor unit terrace mounted, top discharge type factory assembled, pressure tested, refrigerant charged, weather proof M.S casing & coated with baked enamel finish, with Heat exchanger, copper condenser, condenser fan etc., as per manufacturer's standard design.The unit shall be mounted on vibration isolators. The unit shall be completely factory wired, tested with all necessary controls. The outdoor unit shall be modular in design and should be allowed for side by side installation. The unit shall be suitable to operate on 3 Phase, 415 +/- 10 % Volts, 50hz AC power supply. Outdoor unit shall have minimum two nos. of inverter compressors & shall be able to operate even incase of breakdown of one of compressor, the unit shall be provided with its own micro processor control panel & electrical compartment with all necessary electrical & control components.

-

-

-

... More
Outdoor Units-Heat Pump Type 60 HP (20+20 + 20 HP)

4

-

1701000

... More
Indoor Units SITC, Loading, Unloading of the indoor unit. Unit shall be complete in all respect and suitable for 230 ±5% volts include wired thermostat having a dispay showing temperature and control of temperature inside the room. Indoor unit shall include hanging arrangemnt of the unit with necessary supporting rod, nut & bolts,fastners and accessories for complete installation of Indoor unit. User shall be able to adjust the temperature as per their comfort level requirement. High Static Ductable Unit Ductable unit : 4.55 TR

2

-

98280

... More
Ductable unit : 3.98 TR

2

-

85968

... More
Wall Mounted Unit Hi wall unit : 1.59TR

3

-

43200

... More
Imported fittings Y-joints and headers etc.

15

-

10200

... More
Cordless Remote controls

3

-

8700

... More
Communication cable(1.5 sqmm X 2 Core)

750

-

175

... More
CENTRAL REMOTE CONTROLLER Supply,installation,testing and commissioning of central remote controller for the control and monitoring of indoor and outdoor unit. The unit shall have BAC Net protcol .

1

-

202500

... More
SPLIT TYPE AIR-CONDITIONERS Supplying, Installing, testing and commissioning of air-cooled split AC unit, inverter type along with indoor/ outdoor units, controls, copper piping, uPVC condensate drain piping, valves and closed cell nitrile rubber insulation suitable to operate on 230 Volts 50 Hz AC supply etc. Quoted price shall include cost of wireless remote controller, wiring, control cable ,MS stand for placing outdoor unit with rubber pad isolator & earthing. Unit shall be provided with auto timer setting, complete as per technical specifications and tender drawings.The length of refrigerant pipe and drain pipe shall be considered as per drawings.The quoted price shall include cost of refrigerant Hi wall Unit : 1.5 TR

1

-

52000

... More
Hi wall Unit : 2.01 TR

1

-

84000

... More
REFRIGERANT PIPING Supply, fabrication, installation, testing of Interconnecting refrigerant pipe work with closed cell nitrile rubber 'class O' insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS hanger/tie rod .Refer tender specification for detail description.All outdoor refrigerant piping to be protected with Woven Fiberglass cloth, 7 mil thickness and 200 gsm weight, with factory laminated, self-adhesive backing should be used. This needs to be finished with 2 coats of UV painting. 41.3 mm O.D (wall Thickness-1.4 mm) (Insulation: 19 mm)

145

-

2588

... More
34.9 mm O.D (wall Thickness-1.2 mm) (Insulation: 19 mm)

20

-

2012

... More
28.6 mm O.D (wall Thickness-1.0 mm) (insulation : 19 mm)

160

-

1725

... More
22.2 mm O.D (wall Thickness-1.0 mm) (insulation : 19 mm)

20

-

1509

... More
19.1 mm O.D (wall Thickness-1.0 mm) (insulation : 19 mm)

166

-

1402

... More
15.9 mm O.D (wall Thickness-1.0 mm) (insulation : 19 mm)

440

-

1294

... More
12.7 mm O.D (wall Thickness-0.8 mm) (insulation : 13 mm)

70

-

1186

... More
9.5 mm O.D (wall Thickness-0.8 mm) (insulation : 13 mm)

390

-

1150

... More
6.4 mm O.D (wall Thickness-0.8 mm) (insulation : 13 mm)

80

-

1078

... More
Supplying & fixing on existing CC foundation / terrace of M. S. supporting structure made of MS chanels & MS angles etc for installing VRF outdoor units duly epoxy coated / galvanized etc as required.

300

-

216

... More
Supplying and installing following size of perforated pre-painted M.S cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S suspended including bolts & nuts, painting suspenders etc as required. 300 mm width x 50 mm depth x 1.6 mm thickness

450

-

1006

... More
150 mm width x 50 mm depth x 1.6 mm thickness

300

-

719

... More
AIR HANDLING SYSTEM CEILING SUSPENDED AIR HANDLING UNITS Supply, loading, unloading, Lifting, shifting, installation, testing, and commissioning of factory built Double Skinned Chilled water ceiling suspended air- fabricated out of extruded aluminium section with 0.6 mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.8 mm plain Galvanised steel sheet inside with blower with AMCA certified blower , blower section(Suitable static pressure as required , minimum 2 bend GSS/ PVC eliminators ) and blower motor TEFC type with IE-3 Class rating suitable for operation on 415 volts ± 10% , 50 Hz ± 5% AC supply , 4 Row DX-type cooling coil made of Aluminium finned Copper tube( Tube thickness not less than 0.5 mm) with coil section , thermostat ,filter section with non wovensynthetic media of 10 micron particle size with an efficiency of 90% , polished stainless steel drain pan made out of 18 G sheet duly insulated with 13 mm thick closed cell nitrile rubber, complete with motor and belt drive package. The AHU shall be complete in all respect and drain piping as per the specification to be provided to the closest floor drain. The cost shall include 150 mm dia dial type pressure gauges ( 2 nos.) and industrial type thermometer ( 2 nos.) at the inlet and outlet of each type of coil , auto purge valve wherever required, Mixing chamber with return air and fresh air damper , necessary vibration isolation arrangement etc. complete as per specification and drawings., auto purge valve wherever required, Mixing chamber with return air and fresh air damper , necessary vibration isolation arrangement etc. complete as per specification and drawings.The CSAHU panels shall be insulated with 25±2 mm thick & 40 Kg/m³ density PU foam. The motor& blower assembly shall be mounted on Aluminium extruded section only. The complete CSAHU shall confirm to standard specification. The face velocity across cooling coil shall be limited to 400 FPM maximum. The capacity of Air-handlers shall be as follows:CSAHU shall be selected considering 1ºF Chilled temperature rise in piping distribution. . The unit shall be BMS compatible. Total Static pressure given below is minimum required for the system. Actual static pressure to recheck and confirmed by the vendor as per actual site condition before the exceution. 3600 CFM and 9 TR capacity, 4 R.D Cooling Coil, CSU with static pressure 40 mm WG

10

-

222400

... More
CEILING SUSPENDED AIR HANDLING UNITS Supply, loading, unloading, Lifting, shifting, installation, testing, and commissioning of factory built Double Skinned Chilled water ceiling suspended air- fabricated out of extruded aluminium section with 0.6 mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.8 mm plain Galvanised steel sheet inside with blower with AMCA certified blower , blower section(Suitable static pressure as required , minimum 2 bend GSS/ PVC eliminators ) and blower motor TEFC type with IE-3 Class rating suitable for operation on 415 volts ± 10% , 50 Hz ± 5% AC supply , 4 Row DX-type cooling coil made of Aluminium finned Copper tube( Tube thickness not less than 0.5 mm) with coil section , thermostat ,filter section with non wovensynthetic media of 10 micron particle size with an efficiency of 90% , polished stainless steel drain pan made out of 18 G sheet duly insulated with 13 mm thick closed cell nitrile rubber, complete with motor and belt drive package. The AHU shall be complete in all respect and drain piping as per the specification to be provided to the closest floor drain. The cost shall include 150 mm dia dial type pressure gauges ( 2 nos.) and industrial type thermometer ( 2 nos.) at the inlet and outlet of each type of coil , auto purge valve wherever required, Mixing chamber with return air and fresh air damper , necessary vibration isolation arrangement etc. complete as per specification and drawings., auto purge valve wherever required, Mixing chamber with return air and fresh air damper , necessary vibration isolation arrangement etc. complete as per specification and drawings.The CSAHU panels shall be insulated with 25±2 mm thick & 40 Kg/m³ density PU foam. The motor& blower assembly shall be mounted on Aluminium extruded section only. The complete CSAHU shall confirm to standard specification. The face velocity across cooling coil shall be limited to 400 FPM maximum. The capacity of Air-handlers shall be as follows:CSAHU shall be selected considering 1ºF Chilled temperature rise in piping distribution. . The unit shall be BMS compatible. Total Static pressure given below is minimum required for the system. Actual static pressure to recheck and confirmed by the vendor as per actual site condition before the exceution. 3500 CFM and 9 TR capacity, 4 R.D Cooling Coil, CSU with static pressure 40 mm WG

6

-

222400

... More
AHU KIT Supplying, installation, testing and commissioning of expansion kit required for the above floor mounted AHU to make the system complete and suitable for operation of AHUs as per specification as required.

16

-

40500

... More
PRECISION AIR CONDITIONING TYPE (For server room) Supply , Installation , Testing & Commissioning & Handing over of Microprocessor based Dual Fluid (Refrigerant R410a & chilled water) Type High Precision air conditioning unit with R 410 A refrigerant with Bottom discharge consisting of inlet filter section with Eu-4 filters , EC fan motor, fan motor assembly to deliver below mentioned air quantity , Dx Coiling Coil , condensate drain pan , Microprocessor panel , digital display , programmable control & recording unit complete with intelligent 16 digit 2 line alpha numeric display , function keys , cursor keys , free programmable keys ,LEDS , inscription filelds with integrated battery backup supply at 24 V AC 50 Hz. The unit shall be suitable for operation on 415 V 50 Hz AC supply. The Display panel shall display date , time , actual & set values , operating conditions , signal faults , collective faults limiting values. Units Should be with Floor discharge type & Body should be with metal panels with insulation. Heater banks & Humidifier to maintain humidity inside the space. The Unit shall be complete in all respect and shall be factory tested with reports submitted and it should meet the specification,Drawing & Schedule.

-

-

-

... More
The scope of work shall include Lifting, shifting & positioning of Precision air conditioning at location shown on drawing. Quoted price shall include cost of first charge of refrigerant for complete refrigeration circuit, suitable size, epoxy coated MS stand for indoor and outdoor unit, vibration isolators, power cabling, control cabling and earthing. The unit shall have water leak detector which should be able to generate alarm in case of water leakage. Direct Drive motor suitable for 415 +/- 15% V , 50 Hzs , 3P , TEFC squirrel cage induction motor and BHP rating 15% higher than the peak capacity. Fan Arrangement shall be With BACKWARD CURVED for partial load efficiencies. All listed accessories should be part of scope. Necessary BMS integration software & Hardware should be included under the scope of supply. Every two modules together should have one power panel. Insulated Refrigerant piping between indoor & outdoor unit would be in the scope of PAC Vendor. MS stanad for housing indoor unit on the false flooring shall be scope of supply. Height available below false floor shall be clear 600 mm. The BMS shall accept all necessary inputs and outputs including remote start / stop , safety shutdown input , drive trip output etc. , The Display panel shall display date, time , actual & set values , operating conditions , signal faults , collective faults limiting values , relay module for tripping of the unit in case of fire . Equipment should also be equipped with RS 485 Card for BMS integration.The BMS integration card should be compatible with third party BMS system through Open/Modbus protocol. No controlling required from BMS , only monitoring of the parameters/alarms. SS Drain pan Should Be provided with insulation per specification or manufacrurer recomendation. All listed accessories including all accessories should be part of scope. Necessary BMS integration software & Hardware should be included under the scope of supply. Every two modules together should have one power panel. It Shall Include commissioning filter and unit shall be charged with R410 Refrigerant after installation of unit.

-

-

-

... More
Each unit shall have inbuilt sequential controller for operating N+1 configuration. Microprocessor should have inbuilt feature of Team Mode & cascade mode incase required. The controls shall have sepaerate indication of operating modes(cooling, heating, humidifying & dehumidifying), alarm conditions(temperature high, loss of sensor, compressor HP & LP, no air flow and low humidifier water). The unit shall have a provision for auto restart in the event of power disruption. 2 sets of potential free contacts for all drives. The capacity of PAC should be mentioned as below With out any deviation 16 TR ,8000 Cfm/ Module Air quanitity from each unit at a external static of 15 mm of wg PAC Unit with all listed accessories as specified in all the section ( 1 W + 1S)

2

-

378000

... More
AIR DISTRIBUTION GSS DUCT (FACTORY FABRICATED) Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. (a) 24 G (0.63 mm)

2100

-

983

... More
(b) 22 G (0.80 mm)

800

-

1154

... More
GSS DUCT (SITE FABRICATED) Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. (a) 24 G (0.63 mm)

600

-

942

... More
(b) 22 G (0.80 mm)

250

-

1104

... More
VOLUME CONTROL DAMPER Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications.

190

-

6500

... More
SUPPLY AIR GRILL Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

30

-

8480

... More
SUPPLY AIR GRILL Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

30

-

5507

... More
SUPPLY AIR DIFFUSERS Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

30

-

11363

... More
RETURN AIR DIFFUSERS Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.

30

-

7559

... More
EXHAUST AIR LOUVERS Supplying, Installing, testing and commissioning of powder coated extruded aluminium exhaust air louvers with min.60 % free area, with metallic frame work & fixing accessories, to be fixed on external wall to exhaust air from basement area to ambient , it shall be suitable for exhausting required air in CFM . Louvers need to be suitable in order avoid rain water entry in to basement @ 15 degree deflection with bird screen complete as per specification approved drawings and schedules.

70

-

8000

... More
FRESH AIR LOUVERS Supplying, installing, testing and commissioning of GI construction fresh air louvers with min. 60 % free area, bird screen and fresh air filters and painted in baked enamel shade with metallic frame work complete as per specification approved drawings and schedules.

70

-

8000

... More
EXHAUST AIR GRILLES Supplying, Installing, testing, balancing & fixing of powder coated extruded aluminium Exhaust air Grills of various sizes and as per specifications and approved drawings and schedules

120

-

7500

... More
FRESH AIR GRILLES Supplying, Installing, testing, balancing & fixing of powder coated extruded aluminium Fresh Air Grills of various sizes and as per specifications and approved drawings and schedules

120

-

7500

... More
FIRE DAMPER Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire Damper

16

-

9883

... More
Actuator

32

-

9212

... More
PIPING PVC DRAIN PIPING Supply, installation, testing and commissioning of Rigid heavy class uPVC piping with minimum 6 mm nitrile rubber insulation over the pipes ,complete with fittings, supports,U trap arrangement ,clean plug and accessories for units as per specifications and technical specification. 25 mm dia

50

-

216

... More
32 mm dia

55

-

288

... More
20 mm dia

50

-

201

... More
GI PIPING Supply, installation, testing and commissioning of Class "B" GI piping with minimum 6 mm nitrile rubber insulation over the pipes for Drain pipe ,complete with fittings, supports and included accessories for AIR WASHER/DRY SCRUBBER as per specifications, drawings and schedule 32 mm dia

250

-

650

... More
50 mm dia

300

-

1000

... More
INSULATION & ACOUSTIC DUCT INSULATION Supply,Installation,Testing and commissioning of Thermal insulation material for Duct insulation.It shall be anti-microbial closed cell cross linked polyethylene foam with aluminimum foil.Thermal conductivity of the insulation material shall not exceed 0.032 W/moK at an average temperature of 25oC. Density of the material shall be 25-30 Kg/m3. The product shall have temperature range of –40 oC to 105oC. The insulation material shall be fire rated for Class 0 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability as per DIN 52615 shall not exceed 0.15ng/Pa.Sec.m. Thermal conductivity of the material shall not be affected by ageing, as per DIN 52616. The material must be tested for ageing effect in an accredited laboratory for a minimum period of five years to satisfy the ageing criteria. The smoke density of the material as per AS-1530.3 shall not exceed 1. There shall be no toxicity in the emitted smoke, both under flaming and non-flaming conditions, as per AITM 3.000 (1993). The quoted price shall include adhesive and accessories required to fix the insulation inside the duct * Note-Insulation shall be inside the duct in all air conditioning duct. 19 mm on supply/Return duct

1100

-

791

... More
DUCT ACOUSTIC LINING Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.

200

-

647

... More
ROOM ACOUSTIC LINING Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50 mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610 mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.

100

-

1139

... More
DOUBLE LAYER CANVAS CONNECTION Supply,Installation,testing and commissioning of double Layer canvas connection fire retardant cloth for the end connection of AHU/AIR WASHER/DRY SCRUBBER/Ventilation fan to reduce the vibration.It shall be fire rated for atleat 2 hrs.Refer tender specification for detail description

150

-

4500

... More
VENTILATION SYSTEM TUBE AXIAL FAN FOR PRESSURISATION Supply, installation, testing and commissioning of Fire Rated Tube Axial flow fans complete with tube casing, impeller, bird screen, gravity louvers, necessary nut bolts, necessary transition piece and canvas connection for proper installing, directly coupled to TEFC Sq.cage, IE-2 induction motor Class"H" insulation mounted on vibration isolators suitable for 415V±10%, 50 Hz. 3 phase electric supply complete as per the technical specifications enclosed. The fans should be AMCA certified for air performance. The fan should be rated for a minimum of 250 Deg C for a minimum of 2 Hrs. application.The fan shall be complete in all respect and should match the specification and Drawings .The quoted price shall consist of mounting arrangemnt along with spring isolator for fan. For dia upto 1120 mm fan RPM should be 1450 and above 1120mm dia fan RPM should be 950 Note:Noise level should be selected for 3 meter distance from fan at room condition. For normal case - 80db(A)@3m For Emergency case - 90db(A)@3m 6000 CFM ,Total static pressure of 20 MM WG

4

-

78000

... More
8000 CFM ,Total static pressure of 20 MM WG

3

-

104000

... More
9000 CFM ,Total static pressure of 20 MM WG

2

-

117000

... More
Fire Rated Tube Axial Flow Fans for Smoke Evacuation Supply, installation, testing and commissioning of Fire Rated Tube Axial flow fans complete with tube casing, impeller, bird screen, gravity louvers, necessary nut bolts, Necessary transition piece and canvas connection for proper Installing, silencers on inlet and outlet and directly coupled TEFC Sq.cage, EFF-1 High efficiency induction motor mounted on vibration isolators suitable for 415V±10%, 50 Hz. 3 phase electric supply complete as per the technical specifications enclosed. The fans should be AMCA certified for air performance & sound ratings. The fan should be rated for a minimum of 250 Deg C for a minimum of 2 Hrs. Application.The fan shall be complete in all respect and should match the specification ,Drawings and Schedule..The quoted price shall consist of mounting arrangemnt along with spring isolator for fan.The unit shall be capacble to communicate with BMS system. The speed of the motor shall be less than 1450 RPM and the impeller speed shall be less than 1000 RPM and capacities based on minimum static pressure to suit the system. Note:Noise level should be selected shall be 80 db(A) @ 3 meter distance from fan at room condition. 11500 CFM ,Total static pressure of 20 MM WG (Exhaust air Fan & Fresh Air Fan)

8

-

149500

... More
CABINET FANS Supply, installation, testing and commissioning of factory fabricated double Skinned cabinet type fans section made out of extruded aluminium section with 1.0 mm pre-plasticized / pre-coated Galvanised steel sheet with DIDW blower, blower section and TEFC motor suitable for operation on 220 volts ± 5%, 50 Hz ± 5% AC supply with motor and belt drive package. The blower should be AMCA Certified for air performance and sound rating and should be selected for maximum efficiency. The motor & blower assembly shall be mounted on Aluminium extruded section only. The complete fan section shall conform to standard specification. The fan outlet velocity shall be limited to 9.5 MPS maximum..The maximum sound level of unit shall be 60dB(A) @ 3 m from source. (a) 3500 CFM,Total static pressure of 20 mm WG

3

-

78000

... More
(b) 3200 CFM,Total static pressure of 20 mm WG

4

-

76000

... More
(c) 2800 CFM,Total static pressure of 20 mm WG

6

-

67000

... More
(d) 2000 CFM,Total static pressure of 20 mm WG

44

-

64688

... More
INLINE FAN Supply , installation , testing and commissoning , of duct mounted inline fans complete with direct driven centrifugal fan , TEFC squirrel cage induction motor , with efficiency class IE-3 whichever is higher , direct drive arrangement , heavy gauge sheet metal casing , rubber isolator mounts and other accessories.The fan shall be complete in all respect and should match the specification ,Drawings and Schedule. Inline fans shall be of following capacities.The maximum sound level of unit shall be 60 dB(A) @ 3 m from source. (a) 1400 CFM (15 mm Static Pressure)

6

-

18900

... More
(b) 1000 CFM (15 mm Static Pressure)

1

-

13500

... More
(c) 800 CFM (10 mm Static Pressure)

6

-

12000

... More
PROPELLER FANS Supply , installation , testing and commissioning of propeller type fan with Aluminium/SS blades and complete with induction Motor suitable for operation with 230 V single phase 50 Hz with suitable frame etc. as per IS:2312-1967 with gravity dampers for exhaust complete as per specifications and drawings. for fan upto 150 CFM, wall/Ceiling mounted propeller type exhaust fans shall be of slim line Axial Flow type. Fan casing and impeller are manufactured from tough injection moulded poly propylene . Front grill shall be high quality ABS and neon indicators from polycarbonate. Motor shall be of single phase, shaded pole, 230 V, 50 Hz . Noise level should not exceed 45dB(A) @3m.The fan shall be complete in all respect and should match the specification ,Drawings and Schedule.system. 700 CFM

6

-

9450

... More
150 CFM

1

-

3000

... More
ELECTRICAL WORKS

-

-

-

... More
STARTER PANEL Supply, installation testing and commissioning of Direct online starters suitable for motors of air handling units/ Heat recovery wheel/Ventilation fans of below mentioned capacities. The starter shall comprise of all necessary power and control equipments including, Auto / manual selector switch, start / stop push button, LED indication, line contactor, Overload realys, Potential free NO/NC contact for control wiring, 415V actuated relay coil, necessary control wirings properly connected in fully usable state. Minimum utilization catagory for all contactors shall be AC3 and contactor shall be capable to withstand the steady state (full load) and starting inrush current. The starter shall have necessary protection device (MPCB +EOCR) whose settings and ratings shall be as per the type-2 co-ordination chart. The starter shall have inbuilt protection against overcurrent, short circuit and single phasing. All below mentioned starters shall be BMS compatible and additional contacts and wiring required for BMS integration shall be provided. 1.5 kW DOL starter ,4 A circuit breaker with OLR range 2.8-4 A , 16A delta contactor.

18

-

23400

... More
STARTER PANEL Supply, installation testing and commissioning of Direct online starters suitable for motors of air handling units/ Heat recovery wheel/Ventilation fans of below mentioned capacities. The starter shall comprise of all necessary power and control equipments including, Auto / manual selector switch, start / stop push button, LED indication, line contactor, Overload realys, Potential free NO/NC contact for control wiring, 415V actuated relay coil, necessary control wirings properly connected in fully usable state. Minimum utilization catagory for all contactors shall be AC3 and contactor shall be capable to withstand the steady state (full load) and starting inrush current. The starter shall have necessary protection device (MPCB +EOCR) whose settings and ratings shall be as per the type-2 co-ordination chart. The starter shall have inbuilt protection against overcurrent, short circuit and single phasing. All below mentioned starters shall be BMS compatible and additional contacts and wiring required for BMS integration shall be provided. 2.2 kW DOL starter , 5A circuit breaker with OLR range 2-3.2A , 16A delta contactor

5

-

34320

... More
3.5 kW DOL starter , 5A circuit breaker with OLR range 2-3.2A , 16A delta contactor

8

-

54600



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.