Shri Mata Vaishno Devi Shrine Board Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Shri Mata Vaishno Devi Shrine Board - SMVDSB Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date27 Jul 2024
Closing Date8 Aug 2024
Tender Amount₹ 3,62,01,494 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15o landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases ukpto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1 ½ : 3 (1 cement : 1 ½ Coarse sand : 3 graded stone aggregate 20 mm nominal size)

343.13

3370171

9821.85

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts.

418.22

310549

742.55

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers.

589.13

340252

577.55

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Shelves (cast-in-situ)

2845.75

2043817

718.2

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Stairs (excluding landings) except spiral staircases.

14.68

12494

851.15

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Cold twisted bars

52614.9

6482155

123.2

... More
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in: Cement mortar 1:6 (1 cement : 6 coarse sand)

334.44

2532215

7571.51

... More
CEMENT PLASTER IN TWO COATS 18mm Cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1cement : 5 coarse sand) finished with a top layer 6mm thick cement plaster 1:6 (1 cement : 6 fine sand)

3188.48

1310624

411.05

... More
12mm Cement plaster of mix: 13.1.1.1 :4 (1 cement : 4 fine sand)

2772.08

786716

283.8

... More
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 13.88.1 1 mm thick

5960.55

823151

138.1

... More
Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)

3188.48

590506

185.2

... More
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.94.1 New work (Two or more coats applied @ 1.43 litre/10 sqm. Over & including priming coat of exterior primer applied @ 0.90 litre / 10 sqm

2772.08

436048

157.3

... More
VITRIFIED FLOOR TILES Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 of approved make, in all colours and shades laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm

549.07

766007

1395.1

... More
KOTA STONE FLOORING Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)

1148.82

2173280

1891.75

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc complete. 50 mm thick with 20 mm nominal size stone aggregate

1007.27

566236

562.15

... More
Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete.

14.68

32094

2186.3

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 18.2.0 W.C. pan with ISI marked white sold plastic seat and lid.

5

28162

5632.4

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basis of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 18.4.1 One urinal basin with 5 liter white P.V.C automatic flushing cistern.

7

37396

5342.35

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waster of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: 18.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

2

8344

4172.4

... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer-in-charge.

2

824

412.1

... More
Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fitting complete: 32 mm dia

5

687

137.4

... More
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing 18.32.1 Circular shape 450 mm dia.

2

2636

1318.25

... More
G.I. PIPES AND FITTINGS Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Concealed pipe including painting with anti corrosive Bitumastic paint, cutting chases and making good the wall: 20 mm dia, nominal bore

100

55585

555.85

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete 19.7.1.25 to 40 mm nominal

15

10953

730.25

... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer-in-charge.

5

2060

412.1

... More
C.P. BRASS FITTINGS Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS: 8931

20

11665

583.25

... More
Providing and fixing of PVC pipe outside the bathroom to man hole complete job 4” DIA PIPE

200

57000

285

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built upt standard tubular Sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e., at top, bottom and sides with required EPDM rubber/neoprene gasket felt etc. Aluminium sections shall be smooth, rush free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / Panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge(glazing, panelling and dash fasteners to be paid for separately.) Powder coated aluminium (minimum thickness of powder coated 50 microns) 14 gauge

5187.63

2667998

514.3

... More
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineerin- charge. 23.7.1 With average thickness of 120mm and minimum thickness at khurra as 65 mm

1150

1615347

1404.65

... More
Disposal of Mulba for manual means average distance 500 mtrs.

300

142524

475.08

... More
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar

41.66

60759

1458.45

... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 13.91.1 One coat

8600

664780

77.3

... More
Providing anf fixing of carpet mats in class rooms of school building with fevicol marine adhesive after proper cutting and fixing edge to edge including etc.

12755.88

765352

60

... More
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

2500

454000

181.6

... More
Carriage of material by mechanical transport for loading / unloading complete

-

-

-

... More
sand for avg. lead 55 km

441.05

334995

759.54

... More
aggregate for avg. lead 25 km

331.27

153818

464.33

... More
Bricks for avg. lead 60 km

208568

473449

2.27

... More
Carriage of material by head load for avg. lead 3 km

-

-

-

... More
Cement

256.45

287780

1122.17

... More
Sand

441.05

1225404

2778.38

... More
Aggregate

331.27

920393

2778.38

... More
Bricks

208568

1082467

5.19

... More
Steel

55.11

132858

2410.78

... More
Electric Work

-

-

-

... More
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. – Group-C

234

338130

1445

... More
Wiring for light/power plug with 2x2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required

800

220000

275

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

800

267200

334

... More
Wiring / Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (For AC)

1

1621

1621

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required

-

-

-

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

800

220000

275

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire

400

175600

439

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm Conduit.

50

6400

128

... More
25 mm Conduit.

300

43500

145

... More
32 mm Conduit.

30

5520

184

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (Make: - Legrand (Mylinc) / Havell's (Coral)

-

-

-

... More
Modular Switch 5/6 Amp.

38

3914

103

... More
Modular Switch 15/16 Amp.

40

6240

156

... More
Modular Socket 3 pin 5/6 Amp.

38

4636

122

... More
Modular Socket 6 pin 15/16 Amp.

40

7880

197

... More
Modular Bell Push

1

140

140

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Make: - Legrand (Mylinc) / Havell's (Coral)

60

22140

369

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (Make: - Legrand (Mylinc) / Havell's (Coral)

45

1800

40

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (Make: - Legrand (Mylinc) / Havell's (Coral)

-

-

-

... More
1 or 2 Module (75 mmX75 mm

1

298

298

... More
3 Module (100 mmX75 mm)

80

26160

327

... More
4 Module (125 mmX75 mm)

10

3430

343

... More
MCCB, MCB & DB's

-

-

-

... More
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. (Make: - Havell's/ ABB/ Schinder/ Legrand/ L&T) 100 Amps TP&N

1

6084

6084

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make: - Havell's/ ABB/ Schinder/ Legrand/ L&T)

-

-

-

... More
8- way, Double door

4

10292

2573

... More
12- way, Double door

3

6945

2315

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make: - Havell's/ ABB/ Schinder/ Legrand/ L&T) 8 way (4 + 24), Double door

1

5967

5967

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: - Havell's/ ABB/ Schinder/ Legrand/ L&T)

-

-

-

... More
Single pole

70

17920

256

... More
Single pole and neutral 40 Amp.

7

4193

599

... More
Installation, Testing and Commissioning Supply,Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required

-

-

-

... More
LED Tube fitting 14-20 Watt 4 feet long. (Batten 4')

36

14760

410

... More
LED Tube fitting 10 Watt 2 feet long. (Batten 2')

10

3890

389

... More
LED Ceiling light 10-12 Watt (Round)

116

67280

580

... More
Bell Ding Dong

1

170

170

... More
LED Flood Light 50-60 Watt

6

39000

6500

... More
Supply,Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

60

126000

2100

... More
Supply, Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep (10")

5

8750

1750

... More
CABLING

-

-

-

... More
Supply, Installation,Testing and Commissioning of Cables from Main control Panel to sub panel through ducts/ surfacing of size as mentioned below and other items required for completion of job as required. XLPE 3.5 Core 50 Sq.mm Cable Armored (For Main Supply)

50

35500

710

... More
MAIN PANEL

-

-

-

... More
Supply, Installation, Testing and Commissioning of panel 14/16 SWG CRCA fabricated and powder coated, compartmentalized panel with air ventilation and dust/ vermin proof. (A) Main Incoming MCCB: a) 250 Amp, 4P,35 KA MCCB (Make: ABB, Schinder & L&T) = 01 No. b) LED RYB Indicators with MCB Protection (Make: C&S and GE) = 01 Set c) Ammeter with switch and voltmeter and frequency meter with switch (Make: AE) = 01 Set (d) Bus bars: - 400 Amp, 433 Volt, 4 Strips, Aluminum with heat shrinkable sleeves = 01 No. (B) Outgoing MCCB's a) 100 Amp,16 KA MCCB 4-Pole (Make: - ABB/ Schinder and L&T) = 02 Nos.

1

150000

150000

... More
EARTHING

-

-

-

... More
Supply of Chemical earthing (G I electrode earthing) with 50 mm dia and 2.4 Mtr long with heavy duty pre galvanised pipe. The Electrode should be pre-galvanised with 60-8- microns of 2.5 mm thickness wall. The G I Electrode shall be pre filled with Cristaline conductive material (CCM). The inner strip should be 32 X 6 mm with two holes of 10 mm each on the top. The GI Electrode shall be surrounded with 50 Kg (Back Fill Compound) to provide maximum contact between the electrode and Back Fill Compound. The Back Fill Compound should be eco-friendly and NABL approved Lab tested. GI Electrode earthing should be maintenance free and dose not required regular manual addition of watewr. GI Electrode should be made as described in IS 3043, IEEE-837 etc standards. Installation should be done as per the manufacturer Guideline and as per IS3043 Standards (By Soil treatment Process). Main Hole Cover for Earthing Pit. Excavation of earthing pit, placement of electrode in the pit surrounding of electrode with Chemical compound pouring of water around the electrodes to convert the chemical compound into gel. Filling of pit and ramming complete job for installation of Chemical earthing.

2

20000

10000

... More
GI Strip 25X5 (For connection Earth pit to Equipments)

50

11250

225

... More
Supply and laying of 8 No. SWG GI wire.(For connection Earth pit to Equipments)

70

1750

25



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.