Sher E Kashmir University Of Agricultural Sciences And Technology Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Sher E Kashmir University Of Agricultural Sciences And Technology - SKUAST Tender
Machinery and Tools
Eprocure
Opening Date11 Feb 2019
Closing Date1 Mar 2019
Tender AmountRefer Documents
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_SKUST_70933_1Bid Award Id
ViewTender No
AU/CPC/2018-19/03 dated 08-02-2019Tender Authority
Sher E Kashmir University Of Agricultural Sciences And Technology ViewPurchaser Address
-Website
http://http://www.skuastkashmir.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Digital SLR with zoom kit lens Detailed Specifications:- • 24MP - Full frame Sensor
• Tilting/flip-out LCD Screen
• 1920x1080 video resolution
• Built-in Wireless
• 1230 shot battery life
• Double card slot
• Built-in flash
• Full HD movie up to 60p
• Build-in HDR and time lapse
• 6.5 fps continuous shooting
• ISO up to 12800
• 51 autofocus points
With 24-120 mm VR zoom lens kit
1
-
-
Gravity Based Water Purifier Detailed specifications:- • Gravity based water purification, non-electric with storage
• Capacity 23 litres, with water storage capacity 9 litres
• 4-stage water purification, Manual filling
• Food grade non-toxic plastic
• Activated Carbon Germ-kill Processor, purification up to 1500 litres of water
• Transparent chamber
• Warranty minimum 6 months against manufacturing defects
100
-
-
Rotary manual Microtome Detailed specifications:- • With 2-step mechanical trimming, • Silent retraction with ON/OFF selection, • Ergonomically positioned lateral coarse feed wheel with user selectable turn directions • Unique large volume magnetized anti-static section waste tray, • Precision orientation with quick clamping system for specimen clamps, • Universal cassette clamp, • Two-in-one blade holder E for high and low profile blades with lateral displacement function, with colored safety guard and safe blade ejection
• Blade holder base for two-in-one blade holder E. • Two independent hand-wheel locking systems.
• Operator-adjustable force balancing system with spring force compensation
• Section thickness setting 1-60 µm
• Trimming section thickness setting 10 µm, 30 µm
• Specimen feed Max. 24 mm ± 2 mm
• Max. specimen size up to 68 x 48 x 15 mm
1
-
-
Horizontal Gel Electrophoresis Unit with Power Pack (Maxi Unit) Detailed specifications:- • Complete set should be provided that should include base gel running unit, safety lid, at least two sets of each type of casting trays and combs. • Gel trays should be UV-transparent with fluorescent ruler • Electrodes should be easy to remove for easy cleaning • Should have gel-casting gates to cast gels right in the cell, should also be provided with gel caster with a feature of leak proof and tape-free casting Specifications for Gel Caster and Combs • Diamnsions (LXWXH) (cm): 52x28x10
• Gel size (WXL) (cm): 26x32
• Combs sizes (2 sets of combs): 0.75 mm to 1 mm (25 to 100 wells) and 1.5 mm to 2 mm (25 to 100 wells)
• Sample throughput: upto 300
• Base buffer volume: 1200-1400ml
• Bromophenol blue dye migration rates should be 4.5 cm/hr
• No. of Trays: 2 Specifications for Power Supply: • Power Supply should be suitable for horizontal gel electrophoresis, semi-dry and mini tank blotting. • Constant voltage and constant current modes with automatic crossover • Output Voltage: Adjustable from minimum voltage 5-10V to maximum voltage 300-350V with an increment of 1 V or less • Output Current: up to 400/500 mA with increment of 1 mA or less • Output power: Maximum output power should be between 70 to 100 W • Should have at least 4 pairs of terminals / sockets • Digital display (LED)
• Safety: All necessary safety provisions like over load, No load, Sudden change in load, power failure indication, Over Temperature and safe plugs and sockets • Input Voltage: 230V ±10VAC, 50Hz
1
-
-
Spectrometer with Nano Volume identification (Nano drop) Detailed specifications:- • Quantification of sample volumes from 'Microlitres to Millilitres'. • Optics must have the combination of xenon flash lamp with holographic aberration-correctedconcave grating and receiver as CMOS photodiode. • Operating principle must be with two beams: Absorption single-beam spectrophotometer withthe reference beam. • Instrument should operate moment switched on with no warming up time. • Should be compact & stand-alone system to handle sample volume ranging from 1.5 μL to 4 mL. • UV/Vis wavelength range from 200 nm to 830 nm, with spectral scanning feature. • Low volume measuring surface must be of quartz and must be hydrophobic. • System should also allow using conventional quartz/glass/plastic cuvettes in addition to lowvolume measurement. • Must allow rapid and reliable quantification of Nucleic acids and proteins, OD600, dye methods(to calculate the FOI (both nucleic acid & protein). • Should allow acquire data at user-defined wavelengths from 200 nm to 830 nm and at userpreferred pathlength. • Detection range for dsDNA: 2.5 ng/μL – 1500 ng/μL (with defined pathlength of 1 mm). • Concentration via standard series must have curve fit evaluations viz., Regressions (linear,cubical, quadratic), and Interpolations (linear & Spline) with curve sections in detail with viewdirectly on the instrument display. • Should allow transfer of measured data to PC by connecting the device directly to PC withoutany additional software in addition to transfer the data via USB stick. • Must have evaluation methods with factor, standard or standard series. • Must have Multi – wavelength, Dual-wavelength applications with subtraction and divisionanalysis. • Pre-programmed methods for a quick start. • Direct operation on the device. • Measuring results (1,000) can be saved directly on the device. • 100 method programs in memory. • Spectral band width: 4 nm. • Photometric measuring range: 0 A to 3.0 A at 260 nm. • Random error: ≤ 0.002 if A = 0, ≤ 0.005 (0.5 %) if A = 1. • Systematic error: ±1% if A = 1. • Instrument should be European CE Certified. • Instrument should be supplied with disposable uvettes pack of 80. • Instrument should be supplied with MacOS based operating system, 8Gb RAM, 128gb Solid State hard drive system to save the data from spectrophotometer. • Instrument should have one year warranty
1
-
-
Raw Milk Quality Analyser with Adulteration Screening Detailed specifications:- • Range for FAT, SNF and Protein in Raw unhomogenised Cow, Buffalo as well as mixed Milk Samples. Values of each Milk Parameters should be independent. a. 0-13% Fat b. 0-8% Protein c. 0-15% SNF • Accuracy of the Instrument a. Fat: 0.10 SD – (Ref method Rose-Gottlieb) b. Protein: 0.08 SD – (Ref method Kjeldahl) c. SNF: 0.14 SD – (Ref method Oven drying minus Fat) • Repeatability a. Fat: 0.04 SD b. Protein: 0.04 SD c. SNF: 0.08 SD. • Instrument should able to detect five specific adulterations with their name and able to identify difference between pure and non – pure milk spectrum . • Adulteration in Milk should not affect the result of SNF value • Analysis speed required: 70 – 80 Samples per hours. • Sample Quality: Raw Milk in a temperature range of 5C – 40C. • Sample Volume: Should be minimal around 5 ml. • Display: LCD, Graphical Display.• Data Interface: SD Card and RS 232 . • Conformance: IP41.• Electrical Interface: 12V DC, Power Consumption 40 W. • Built-in Diagnostics: Interferometer test. Cuvette test. Stability test.Cleaning Message display. Error Message display.• Technology of analyser should be meet / approved by global standards IDF and AOAC for Milk Analysis based on spectrum technology. • Instruments should be operated in field conditions of Chilling Centres, Bulk Milk Coolers and Village Level Milk Collection Centres. The instrument should be fully functional and installed at minimum 1000 locations including reputed Co-operative Milk Societies and Private Dairies anywhere in India. Installation certificates of important locations to be provided. • Training and Installation services should be offered along with the Instrument at site and should be supplied with one year on warranty.
1
-
-
Multipurpose Refrigerated Micro centrifuge Detailed specifications:- • Centrifuge 230V/50-60Hz
• Automatic rotor recognition • Compatible with plate, microcentrifuge tube and falcon tube/oakridge tube specific rotors
• Stores up to 50 routine programs
• Fast temperature attainment and temperature attainment at preset time
Technical specifications:
• Maximum speed: at least 17,500rpm with fixed angle rotors and at least 4000 rpm with swing bucket rotors
• Maximum RCF: 30,130 x g
• Acceleration time to max.rpm:20s
• Braking time from max.rpm:20s
• Soft ramp: adjustable • Timer: 30 s – continuous
• Noise level – 56dB
• Temperature range: -10°C to 40°C
• Power requirement: or equal to 750 W
1
-
-
Bench Top Refrigerated Centrifuge:- • Max speed : 20000 RPM
• Max RCF : 37570g
• Max. tube size : 100ml
• Max. capacity : 400ml
• Lowest temperature : -8oC
• W x D x H :775 X 575 X 475
• LCD Display.
• CFC free refrigeration system.
• Pre cooling.
• 9 Acceleration & 9 Deceleration Profiles.
• Calibration window on lid for speed.
• Digital Control Communication.
• Self-Diagnostics of Errors.
• Parameters setting switches: Bi-directional encoder.
• Brushless motor with frequency drive.
• Inverter fault detection with auto shut down.
• 99 No. of programs.
• Last set parameters recall.
• Choice of RPM/RCF setting.
• Temperature display: oC/ oF.
• Digital countdown timer 0-99 min. & continuous run.
• Log of cumulative run time.
• User defined program name for 5 programs.
• Angular rotor of capacity 24x1.5ml(20,000 RPM), 6 strips of 8 x 0.2 ml(11,000 RPM)
• Angle Heads suitable for Falcon Tubes : 12 x 15 ML(11,000 RPM) ,
• Supply : 220-240 Volts, 50 Hz, Single Phase
• With Voltage Stabilizer 3 KVA
• CE Certificate, ISO Certified, Calibration Certificates and IQ, OQ and PQ Documentation.
1
-
-
Large Animal Anaesthesia Machine:- Large animal anaesthesia machine for inhalation anaesthesia in Cattle, Buffalo and Equines:
• Isoflurane vaporiser.
• Time cycled and electrically controlled inbuilt ventilator.
• Breathing bag 15 L and 30L.
• Endotracheal tubes (ET) for cattle, buffalo and equines of different sizes.
• Provision for both closed as well open circuit.
• Circle absorber.
• Adjustable pressure limit valve.
• Control system for inspiratory and expiratory flow.
• Adjustable tidal volume 5-15 liters.
• 0-10 liters per minute oxygen flow meter.
• Frequency control variable from zero to ninety breaths per minute in one BPM increments.
• Inspiratory flow controlled through operator adjustable regulator.
• Touch control tidal volume adjustment.
• Vapour exclusion system.
o In build foal absorber.
1
-
-
Atomic Absorption Spectrophotometer:- • Operation mode: Atomic Absorption, Flame Emission, AABGC (With D2 Lamp), Molecular Absorption.
• Wavelength Range: 175 nm to 900 nm.
• Photometric System : High-speed dual frequency simultaneous photometric
• System.
• Number of lamps that can be lit simultaneously - 01 to 06
• Lamp holder accepts six lamps on turret, positioning should be Automatic.
• Bandwidth: Variable from 0.1 to 2.0 nm, with step of 0.1 nm.
• Wavelength Accuracy : ±0.5 nm
• Absorbance Range : -0.301 to 2.000 Abs
• Hyper pulse background correction
• Gas control module • Flame Ignition and extinguish: Automatic.
• Gas Flow Controls : Automatic Flow rate control
• Signal Processing : Displays real time signal
• Accessories required with AAS, gas Cylinder and regulator with panel, Exhaust Hood, Air compressor.
• Data Management System: Computer having Processor i5-quard core and latest version of windows based operating software along with LaserJet printer
• System should be supplied with branded Voltage Stabilizer or Compatible UPS with half hour battery backup. Warranty : Three years after installation
1
-
-
Poultry Incubator Detailed specifications:- 1000-1200 eggs capacity with fully automatic and digitally controlled setter cum Hatcher with following specification:
• The incubator body is made up of 2.7 mm laminated phylum sheets, highly durable, reinforced and easy to clean.
• High density (EPS) Thermo coal for better insulation. • Digital temperature and humidity control with electronic sensor.
• Digital display • Temperature measurement accuracy: ±0.1°C.
• Humidity control accuracy: ±5%RH
• Fully automatic egg turning.
• Inside light with on-off button in panel. • Stainless inner mechanism.
• Air route-perfect laminar flow forced ventilation with unique fan.
• Adjustable air ventilation for air current control.
• Setter Trays: Specially designed (HIPS) 101 eggs capacity seeting trays.
• POWER BACKUP: 2KVA Inverter with 3 batteries and 6 hours backup which is suitable for 1020 Eggs.