Public Works Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Public Works Department - PWD Tender
Healthcare and Medicine
Eprocure
Opening Date13 Dec 2024
Closing Date23 Dec 2024
Tender Amount₹ 65,80,000
Costs
EMD
₹ 1,32,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDJK_267879_1Tender No
MHDJ/e-NIT 170 of 2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://jkpwdrb.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
WALLANDCEILINGPANELINSTALLATION
Labour, material installation on site etc
1
-
-
... More
ANTI-STATIC VINYLFLOORINGWITHCONDUCTING.
1) Antistatic Vinyl Flooring provides high protection against static charges making it the ideal choice for control rooms, laboratories, information technology centers, semi conductor and electronics industries. Conductive performance is permanent and does not depend on air humidity or temperature conditions. 2) Seamless antistatic conductive flooring with the thickness=1mm, with perfectly curved flashing covings, all joints are welded as per the colours & patterns. 3) The tiles are laid on the smooth sub-floor, done with a suitable self-leveling compound. 4) These material is conductive enough to dissipate the static electricity; without endangering personnel from the static electric shocks. 5) Shades of the antistatic vinyl flooring will always according with the client choice & as well as to see with the ground purpose.
670
-
-
... More
ANTISTATICVINYLFLOORINGINSTALLATION
Antistatic flooring/labour/route etc. Antistatic Vinyl flooring provides high protection against static charges making it the ideal choice for control rooms, laboratories, information technology centers, and semiconductor and electronics industries. Conductive performance is permanent and does not depend on air humidity or temperature conditions.
1
-
-
... More
ALUMINIUMCOVING
1) Aluminum or PVC Dimensions 65 mm radius x 4000 mm MaterialsAluminium6063backingangle.PVCfacingFixingBackinganglefixedwith screws and coving clips into place Sealing Coving can be sealedat either edge with proprietary sealant. 2) Coving provides a way toeliminate90degreeangleswithintheclean roomenvironment.Suppliedin2parts, thecovingprovidesarounded,flushandeasytoclean corner. Welded aluminium internal and external cornersavailable.
133
-
-
... More
VINYLCOVING
1) Vinyl coving Dimensions 65 mm radius x 4000 mm Materials STEEL6063 backing angle facing Fixing Backing angle fixed with screws and coving clips into place Sealing Coving can be sealed at either edge with proprietary sealant. 2) Coving provides a way to eliminate 90degree angles within the clean room environment. Supplied in 2 parts, the coving provides arounded, flush and easy to clean corner. Welded aluminIum internal and external corners available.
95
-
-
... More
CEILING SUSPENDED AHU CUM LAMINAR DUCTLESS AIRFLOW SYSTEM (CEILINGAHU):PCS- 8TR.
Aluminum composite panel double skin acoustic panel body with aluminium profile and thermal break aluminum body of air handling unit to maintain the sound level to 60db which as per to NABH Guideline. The Ductless Air Handling Unit has following Features: 1) AHU Capacity - 8 TR as per the site requirement. 2) Has fresh air damper in the unit to get desired level of fresh air and to maintain positive pressure. 3) 20 air cycle per hour to keep room air more sterile and ess load on air conditioning. 4) 8 TR outdoor unit is given for air conditioner to get desired temperature 21 +/- 3 degree cooling in room. 5) 1500 CFM to get minimum 20 to 30 air cycle/hours to minimize biological burden and suffocation. 6) Has climate control system to get desired temperature in room when outside temperature is low. 7) U.V. light do not allow fungus to grow in cooling coils in PCS to ensure sterile air, Air particle count will not be more than class IV (1000-10000 ppm) in any corner of the room. Level of pre filters 5 and 10 microns each. HEPA FILTER of 0.3 micron. Necessary dampers for fresh air than supply chamber. DX cooling coils as per the cooling requirement of the room (18-21 degree). Based upon the room volume to support 20 to 30 air changes the necessary CFM of the AHU. It has dehumidifier circuits with necessary reverse valve and all other standard accessories for mounting the AHU.
1
-
-
... More
AHUACCESSORIES (COPPERPIPING,ACCESSORIES,GRILLS AND DAMPERS INSTALLATION)
1) Supply and erection of the hard drawn copper piping controlcablingbetweenIDU&ODUwiththenitrilerubberinstallationasperthe standards. 2) Supply and erections of the service valves, thermostatic expansion valves, charging of the refrigerants, drierwith the shut off balls valves etc. 3) Supply and fixing of the extruded aluminium grills including necessary accessories.
1
-
-
... More
CEILINGSUSPENDEDAHUCUMLAMINARAIRFLOW INSTALLATION
Labour,installation,tools ,material,etc.
1
-
-
... More
LEDPERIPHERALLIGHT
In false ceiling 2'X1'with light Intensity 50000 Lux
12
-
-
... More
SURGEON'S CONTROL PANEL
The surgeon control panel should meet Electrical safety codes forhigh & low voltage system, wired to the current IEE regulations. Theroom Surgeon’s control panel should be modifiable with changingtechnology & equipment in operating environments. Control Panelwill be user friendly & ease of operating & maintaining purpose. Thepanel should be “Membrane” type; configured t o incorporate all theservicesthatoperationroomstaffrequired.Thefasciashouldbemadewith superior quality UV resistance membrane with sterilizationfeature. The Panel should contain 6 or 9 service tiles as below: 1.TimeDayClock.2.TimeElapseDayClock.3.GeneralLightingSystem. 4. Medical Gas Alarm Panel. 5. Hand Free Telephone set with memory.6. Temperature & humidity indicator with controller. 7. HEPA FilterStatus module. 8. Room Pressure Indicator. 9. Music control. Time dayclock should be digital type & clocks having high brightnesscharacters. Time Elapsed Day Clock should be digital type & clockshaving high brightness characters. Temperature indicator shouldindicatetheroomtemperaturewhichshouldbeconnectedtothelocalpressure switches of Air-Conditioning System. Indicators should bedigital type & clocks having high brightness characters, not less than30 mm in height. Central Lighting system should incorporate all thenecessary controls of the lighting. System inside the theatre. Themedical gas alarm should indicate High, Normal & Low gas Pressureforeachgasservicepresentintheoperatingsystem&shouldhaveanaudible buzzer with mute facility. Pressure sensors should beconnected to MGPS for monitoring the pressures. A hand free setTelephone System should be incorporated in the panel with memorytype card. The control panel should be designed for front- access only.All internal wires should be marked with plastic Ferrule type cablemarkersforeaseofidentification
1
-
-
... More
SS Pass Box:- SS 304 pass box having double door with interlock, Solid door with electrical interlocking, Window with tempered glass, UV lamp for sterilization.
Storage Unit Providing and fixing Storage unit of size 1800 X 1200 X 250mm having three
Shelves made of SS 304 grade, 5mm thick, Heat strengthens anti-microbial coating glass shutters.
Writing Board flush mounted with sterile jointing systems, 1.50 MM thick white laminate board, bended to a 02 MM steel sheet for the additional rigidity.
Modular stainless surgical scrub station or sink specially designed for the use in Operation Theater. It should be easy and conveniently foot operated & sensors based for hand free operation. It should be designed for the use of minimum two surgeons simultaneously. Job also includes dismantling of existing sanitary fittings and providing/laying of scrub station with latest facilities with all fittings, accessories and civil works
1
-
-
... More
Provision for Audio Video conferencing system with professional 65” LED screen along with allied works for executing complete setup.
11
-
-
... More
Modular Operation Theater LED Lights having 02 No of Lights each having minimum intensity of 160000 Lux, Depth illumination of minimum 10 cm, suitable spot diameter especially required for precision surgeries, having both manual and remote controlled facility and operating on 220 V/50 Hz AC.
1
-
-
... More
X-RAY VIEW BOX CONCEALED
X-Ray view box is the necessary equipment in hospitals, medicalinstitutes, and nursing homes. This single film X-ray view box isexcellent in functioning and ensures optimal viewing quality due totheLED-basedviewing. 1)Body: Powdercoatedmscabinetwithmetalframe. 2)Sheet: Acrylicsheet.3)Power: 12v,50-60hz. 4)Bulb: Highglossy LED bulbs. 5)Parts: Heavydutyswitchand socket used. 6) Safety: Shock proof mechanism. 7)Holding: Plastics clips for x-ray film holding. 8)Handling: Light weight & portable. 9) Dimmer: Dimmer toadjustthebrightnessofscreen.
1
-
-
... More
PRESSURERELEASEDAMPER
All operation rooms should be supplied with multi bladed damper specifically designed to control room air pressures and protection top the Doors should be provided within the modular panel. Each stabilizer comprises of a matching slip over rear flange coated in white color and exterior grille. The pressure dampers will contain four grade 304 SS Blades which pivot upon sealed for life bearing assemblies. It should have CE compliance under Class 1 Medical devices directive.
1
-
-
... More
1) HERMATICALLY SEAL DOUBLE DOOR.
Swing Manual Door
Hermatically sealed clean room door( Double leaf type door) in OT Doors shall be designed to fit flush into the wall panel systems. Doors shsll be fabricated panel systems on both sides doors shall be fabricated from the PPGI sheets standard 30mm-50mm panel shall have frame width of 50mm & shutter width of 45 mm.
The following accessories shall be the part of the door:
1.Shutter thickness 45mm
2. Stainless steel hinges
3. Stainless steel d type of handles on pull side.
4.Standard type door cloure.
5. View pael along with self adh-tape and the silicon sealent.
6.Single side key operated locking arrangement.
7.automatic door bottom sealed
8.Stainless steel kick plates.
9.Flush mounted with sterile joinig systems.
10.it’s a1.50 mm thick white laminate board
11. bended to a 2mm steel sheet for the additional rigidity.
1
-
-
... More
) 1)HERMATICALLY SEALED SINGLE SWING MANUAL DOOR. Hermatically sealed clean room door( Single leaf type door) in OT Doors shall be designed to fit flush into the wall panel systems. Door shall be fabricated panel systems on both sides doors shall be fabricated from the PPGI sheets standard 30mm-50mm panel shall have frame width of 50mm & shutter width of 45 mm.
The following accessories shall be the part of the door:
1.Shutter thickness 45mm
2. Stainless steel hinges
3. Stainless steel d type of handles on pull side.
4.Standard type door closure.
5. View pael along with self adh-tape and the silicon sealent.
6.Single side key operated locking arrangement.
7.automatic door bottom sealed
8.Stainless steel kick plates.
9.Flush mounted with sterile jointing systems.
10.it’s a1.50 mm thick white laminate board
11. bended to a 2mm steel sheet for the additional rigidity.
3
-
-
... More
OZONEGENERATOR (SOLUTION FOR FUMIGATION)
1) Magical air disinfection without any chemicals. 2) Ozone generatorkillsalltypesofbacteria,fungus,virus, molds. Functions: 1) Formaldehyde treatment after house fitment Peculiar smell removing, bleaching, decolorizing of restroom. 2) Peculiar smell elimination for cabinet, refrigeratory, lampblack, rubbish. 3) Poisonous gas decomposing such as toluene, ethanol, carbon monoxide, sulfur dioxide. 4) Deodorization of chifforobe, shoes cabinet. 5) With ozone water have a bath to possess to bleach and the effect such as cosmetology and health protection
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%